Loading...
HomeMy WebLinkAbout20140759 Ver 1_Site Plan_20140923 (6)VELOCITY REDUCTION PADS OUTLET # PIPE SIZE (IN.) ROCK SIZE (IN.) ZONE ROCK CLASS LENGTH L (FT.) WIDTH W (FT.) DEPTH (IN.) VELOCITY V10 71 30 25 3 1 7.5 7.5 25 13.2 OS3 36 12 2 B 9 9 24 9.6 SIDE C EXISTING GROUND GATE VALVE AND POND o DRAIN, SIZE -6" o OS3A RIP -RAP OUTLET DETAIL N.T.S. OUTLET STRUCTURE GENERAL NOTES 1. OUTLET STRUCTURE ELEVATIONS SHOWN ON THE DETAILS ON THIS SHEET ARE CRITICAL AND MUST BE WITHIN 0.02' OF THAT SHOWN. IF OUTLET STRUCTURES ARE PRE -CAST OFF -SITE, THE HOLE FOR THE OUTLET PIPE SHALL BE ENLARGED TO ALLOW UP TO 0.3' OF VERTICAL MOVEMENT. WHEN INSTALLED, THE EXCESS OPENING SHALL BE FILLED WITH GROUT. 2. THE OUTLET STRUCTURE SHALL HAVE A TRASH RACK COVERING THE OPENINGS. SUCH TRASH RACK SHALL BE 6" OUT FROM THE OPENING AND SHALL HAVE A MAXIMUM OPENING OF 6 "x6 ". IT SHALL BE SECURELY FASTENED TO THE STRUCTURE BUT REMOVEABLE FOR MAINTENANCE. 3. OUTLET PIPES SHALL HAVE AN ANTI -SEEP COLLAR OF CONCRETE LOCATED APPROXIMATELY UNDER THE MIDDLE OF THE DAM IN WHICH IT IS LOCATED. IT SHALL CONSIST OF CONCRETE POURED AROUND THE PIPE IN A VERTICAL DIRECTION. THE COLLAR SHALL BE A SQUARE 8" THICK AND SHALL EXTEND 18" BEYOND THE OUTSIDE OF THE PIPE IN EACH DIRECTION. 4. TREATMENT OUTLET PIPE SHALL NOT BE PVC BUT OTHER MATERIAL SUCH AS GSP WHICH IS NOT SUBJECT TO DETERIORATION IN SUNLIGHT. POND NOTES 1. SEE SHEET 2 FOR BMP CONVERSION SEQUENCE. 2. FOREBAY DIVIDERS ARE TO BE INSTALLED WHILE CONVERTING FROM SEDIMENT BASIN TO WET POND. 3. GROUND WATER NOT ENCOUNTERED. TREATMENT VOLUME ELEVATION- 393.1 10 YR. STORM ELEV. 394.5 - -- ---- _� - - - -- FREEBOARD 1.0; 10' NORMAL POOL- 391.50 10' 10:1 FOREBAY _�v - FOREBAY DIVIDER h -= BOTTOM OF FOREBAY 1' CLAY LINER TRASH RACK DETAIL N.T.S. �- #57 STONE TOPPED BY CLASS B RIP -RAP RETENTION POND CROSS - SECTION NOT TO SCALE 6" TRASH RACK OUTLET STRUCTURE TRASH RACK NOTES 1. TRASH RACK SHALL BE 6 CLEAR OF STRUCTURE TOP AND SIDES. BOTTOM SHALL BE 1" OR MORE BELOW SLOT. THE TRASH RACK NEED NOT COVER THE TREATMENT OUTLET PIPE. 2. TRASH RACK SHALL BE FASTENED TO EACH SIDE OF THE STRUCTURE AT AT LEAST 2 POINTS. IT SHALL BE EASILY REMOVED FOR MAINTENANCE OR ENTRY INTO THE STRUCTURE. 3. TRASH RACK SHALL ACCOMMODATE VALVE SHAFT THOUGH AN OPENING. 4. TRASH RACK SHALL BE MADE OF DURABLE MATERIAL WHICH WILL NOT RUST OR DETERIORATE IN SUNLIGHT AND IS ACCEPTABLE TO THE TOWN OF HOLLY SPRINGS. 5. MAX. OPENING IN TRASH RACK SHALL BE 6"x6 ". 6. TOP OF TRASH RACK SHALL HAVE A GRID OF BARS (MAX. 6"x6 "). no TOP DAM- 395.5 1ST. 1" -TOP SHELF 0.5' ABOVE P.- 392.0 BOTTOM SHELF 0.5' BELOW ,N.P. -391.0 PROVIDE 4 TOPSOIL ON 10 SHELF 1' SEDIMENT STORAGE -BOTTOM OF POND TOP OF DAM -39 PLAN VIEW OS1 OUTLET STRUCTURE N.T.S. I 20' DRAWDOWN PIPE OUTLET PIPE, SI AND MATERIAL PER DRAINAGE SCHEDULE v _ i a.: I / / / 777-7777 77777 - ' ANTI -SEEP COLL R. (SHOULD BE PLACED / r APPROX. IN THE MIDDLE OF EARTH DAM) 1 \ V / r� 1 J 72 � FOREBAY DIVIDER ' v .- r NOTE: ,?,. WALL THICKNESS AND REINFORCEMENT DESIGN TO BE a ?� DETERMINED BY PRECAST CONCRETE MANUFACTURER U 3MP3 rf }} CIOi' EMERGENCY SPILLWAY CROSS- SECTION WET POND �3 BOTTOM EL 386.0 NORMAL POOL- 391.5 TOP OF DAM- 395.5 HAND WHEEL---J (ABOVE TRASH RACK) PRECAST CONCRETE POND DRAIN ELEV. -388.0 EMERGENCY SPILLWAY / _____ 77 f .sic t 13 rs:{ 0S3A E X I � OS3 RI RA _ 2 / v 1b �/ \ 39 t TOP ELEV. -393.1 STANDARD MANHOLE STEPS AT 16" O.C. SHALL BE PLACED ABOVE BRACKET OUTLET PIPE ON OUTSIDE OF STRUCTURE -SHAFT DRAWDOWN PIPE 2" DIAM. INV.- 391.5 388.0 161' TO FES r-24" RCP © 1.0% 8" GATE VALVE GROUT 16' -8 "DIP BOTTOM _ POND BOTTOM SLOPE TO DRAIN + it =i IIIii I -iii Ali =_ I II III1� Ili III III iii. li ��! -I i lit_m -_- _- LANDSCAPE PLAN: THICKNESS 38.25" SHALLOW LAND= 2,722 sf USE 302 PLANTS FROM LIST ABOVE (MIN. FOR ANTI - FLOATATION) SHALLOW WATER- 2,520 sf (USE 282 PLANTS FROM LIST ABOVE) USE EQUAL NUMBER OF PLANTS FROM LIST ABOVE \- CONCRETE BOTTOM CROSS SECTION OS1 OUTLET STRUCTURE N.T.S. i• • MINIMUM REQUCT:EMENTS FQ:R EDUCATIONAL SIGNAGE FOR USE IN CONJUNCTION WITH STRUCTURAL STORMWATER BEST MANAGEMENT PRACTICES MIN. 18 "- MAX. 36" Structural Stormwater Best Management Practice (BMP) This BMP is designed to treat strormwater runoff to reduce the risk of flooding and improve water quality. You can help it function properly by: not dumping trash or yard waste, recycling or safely disposing of pet waste, oil and other chemicals. This BMP is inspected and maintained by: (Add owner name and contact information) FOR QUESTIONS AND CONCERNS PLEASE CONTACT OWNER. Town of Holly Springs Environmental Services and Stormwater Management Division at (919) 557 -4011 or at stormwatekhollyspringsnc.us j 0.5" DA. CENTERED MOUNTING; MOUNTING HOLES (2) 1. SIGN SHOULD NOT BE OVER 8 FT TALL AT HIGHEST POINT. 2. SIGN SHOULD BE MOUNTED TO A U- CHANNEL POST (ADD SPECS) OR AFFIXED TO FENCE. NOTE: 1, DECORATIVE BMP EDUCATIONAL SIGNAGE WILL BE REVIEWED ON A CASE BY CASE BASIS. 2. MATERIAL TO BE ALUMINUM, LETTERS TO BE BLACK ON A WHITE BACKGROUND, 3. SIGN SIZE AND MATERIAL MAY SE MODIFIED FOR THE SPECIFIC NEEDS OF THE STORMWATER BMP, BUT SHOULD BE NO SMALLER THAN 18" X 18" AND NO LARGER THAN 36" X 36 ". BMP Educclionel Signcge STANDARD DETAr - -- DA TE REVISIONS TOWN OF ROLL Y SPRINGS ENGINEERING DEPARTMENT 0_A_ WET PROPOSED 1 18" MAX. 36" 0.5" (TYP. ) DRAWING NOT TO SCALE Z O w El 13 El U jai 5 Hugh J. Gilleece and Associates 875 Walnut Street Suite 360 Cary, NC 27511 BUSINESS LIC. # C -496 Phone: (919)469 -1101 Fax: (919)460 -7637 %/ % /;' / 7I-1 o,c c� G 0 0 Lei L� W o,o o zz z a Z 000 L- I-ILL- Q a�O�rn • • li DSN CHK BY: DS DWN BY: BH DATE: 4/21/2014 HRZ SCALE: 1 " =20' VRT SCALE: NONE :4 &N, �I PLANT LIST LITTORAL SHELF PLANT SCHEDULE: SHALLOW LAND (HERB.) EF EUPATORUIM FISTRULOSUM JOE PYE WEED 4 -6" POT @ 3' SPACING HC HIBICUS COCCINEA SCARLET ROSE MALLOW 4 -6" POT @ 3' SPACING DL DICHROMENA LATIFOLIA WHITE STAR GRASS 4 -6" POT @ 3' SPACING HG HIBISCUS GRANDIFLOURS VELVET MALLOW 4 -6" POT Cam? 3' SPACING CG CHELONE GLABRA WHITE TURTLEHEAD 4 -6" POT @ 3' SPACING LC LOBELIA CARDINALIS CARDINAL FLOWER 4 -6" POT Cam? 3' SPACING SHALLOW WATER (HERB.) JE JUNCUS EFFUSES SOFTRUSH 4 -6" POT @ 3' SPACING AS ACORUS SPP SWEET FLAG 4 -6" POT @ 3' SPACING IV IRIS VERSICOLOR BLUE FLAG IRIS 4 -6" POT © 3' SPACING PC PONTEDERIA CORDATA PECKEREL WEED 4 -6" POT Q 3' SPACING PV PELTANDRA VIRGINICA ARROW ARUM 4 -6" POT @ 3' SPACING SL SAGITTARIA LONGILOBA ARROWHEAD 4 -6" POT @ 3' SPACING EMERGENCY SPILLWAY CROSS- SECTION WET POND �3 BOTTOM EL 386.0 NORMAL POOL- 391.5 TOP OF DAM- 395.5 HAND WHEEL---J (ABOVE TRASH RACK) PRECAST CONCRETE POND DRAIN ELEV. -388.0 EMERGENCY SPILLWAY / _____ 77 f .sic t 13 rs:{ 0S3A E X I � OS3 RI RA _ 2 / v 1b �/ \ 39 t TOP ELEV. -393.1 STANDARD MANHOLE STEPS AT 16" O.C. SHALL BE PLACED ABOVE BRACKET OUTLET PIPE ON OUTSIDE OF STRUCTURE -SHAFT DRAWDOWN PIPE 2" DIAM. INV.- 391.5 388.0 161' TO FES r-24" RCP © 1.0% 8" GATE VALVE GROUT 16' -8 "DIP BOTTOM _ POND BOTTOM SLOPE TO DRAIN + it =i IIIii I -iii Ali =_ I II III1� Ili III III iii. li ��! -I i lit_m -_- _- LANDSCAPE PLAN: THICKNESS 38.25" SHALLOW LAND= 2,722 sf USE 302 PLANTS FROM LIST ABOVE (MIN. FOR ANTI - FLOATATION) SHALLOW WATER- 2,520 sf (USE 282 PLANTS FROM LIST ABOVE) USE EQUAL NUMBER OF PLANTS FROM LIST ABOVE \- CONCRETE BOTTOM CROSS SECTION OS1 OUTLET STRUCTURE N.T.S. i• • MINIMUM REQUCT:EMENTS FQ:R EDUCATIONAL SIGNAGE FOR USE IN CONJUNCTION WITH STRUCTURAL STORMWATER BEST MANAGEMENT PRACTICES MIN. 18 "- MAX. 36" Structural Stormwater Best Management Practice (BMP) This BMP is designed to treat strormwater runoff to reduce the risk of flooding and improve water quality. You can help it function properly by: not dumping trash or yard waste, recycling or safely disposing of pet waste, oil and other chemicals. This BMP is inspected and maintained by: (Add owner name and contact information) FOR QUESTIONS AND CONCERNS PLEASE CONTACT OWNER. Town of Holly Springs Environmental Services and Stormwater Management Division at (919) 557 -4011 or at stormwatekhollyspringsnc.us j 0.5" DA. CENTERED MOUNTING; MOUNTING HOLES (2) 1. SIGN SHOULD NOT BE OVER 8 FT TALL AT HIGHEST POINT. 2. SIGN SHOULD BE MOUNTED TO A U- CHANNEL POST (ADD SPECS) OR AFFIXED TO FENCE. NOTE: 1, DECORATIVE BMP EDUCATIONAL SIGNAGE WILL BE REVIEWED ON A CASE BY CASE BASIS. 2. MATERIAL TO BE ALUMINUM, LETTERS TO BE BLACK ON A WHITE BACKGROUND, 3. SIGN SIZE AND MATERIAL MAY SE MODIFIED FOR THE SPECIFIC NEEDS OF THE STORMWATER BMP, BUT SHOULD BE NO SMALLER THAN 18" X 18" AND NO LARGER THAN 36" X 36 ". BMP Educclionel Signcge STANDARD DETAr - -- DA TE REVISIONS TOWN OF ROLL Y SPRINGS ENGINEERING DEPARTMENT 0_A_ WET PROPOSED 1 18" MAX. 36" 0.5" (TYP. ) DRAWING NOT TO SCALE Z O w El 13 El U jai 5 Hugh J. Gilleece and Associates 875 Walnut Street Suite 360 Cary, NC 27511 BUSINESS LIC. # C -496 Phone: (919)469 -1101 Fax: (919)460 -7637 %/ % /;' / 7I-1 o,c c� G 0 0 Lei L� W o,o o zz z a Z 000 L- I-ILL- Q a�O�rn • • li DSN CHK BY: DS DWN BY: BH DATE: 4/21/2014 HRZ SCALE: 1 " =20' VRT SCALE: NONE :4 &N, �I