Loading...
HomeMy WebLinkAboutNC0024244_Compliance Evaluation Inspection_20220831ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Michael Ferris City of Albemarle PO Box 190 Albemarle, NC 28002-0190 NORTH CAROLINA Environmental Quality September 2, 2022 SUBJECT: Compliance Inspection Report Long Creek WWTP NPDES WW Permit No. NC0024244 Stanly County Mr. Ferris: The North Carolina Division of Water Resources conducted a Compliance Evaluation Inspection (CEI) of the Long Creek WWTP on August 16, 2022. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0024244 and SOC S19-007. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions regarding this inspection, please do not hesitate to contact Roberto Scheller with the Water Quality Regional Operations Section in the Mooresville Regional Office at 704-663-1699 or via email at roberto.scheller@ncdenr.gov. Sincerely, DocuSigned by: 44+w H P;zpa,. -F161 FB69A2D84A3... Andrew Pitner, Acting Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: Laserfiche Bryan Hinson (Water/Wastewater Resource Manager): blhinson@albemarlenc.gov Brandon Plyler (ORC) email: bplyler@albemarlenc.gov D_E NORTH CAROLINA ow..m�.m or Environmental o�.i� North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 11611 Mail Service Center I Raleigh, North Carolina 27699-1611 919.707.9000 United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code 1 IN I 2 21IIIIII L NPDES yr/mo/day Inspection 3 I NC0024244 111 121 22/08/16 117 Type 1810I IIIIIIIIIII Inspector Fac Type 191S I 2011 IIIIIIIIIII IIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 I 70I2 I 711 1 72 I N I 731 1 74 71 I I J I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES Dermit Number) Long Creek WWTP 1040 Coble Ave Extension Albemarle NC 28002 Entry Time/Date 09:41AM 22/08/16 Permit Effective Date 18/12/01 Exit Time/Date 12:26PM 22/08/16 Permit Expiration Date 22/02/28 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Michael J Ferris,PO Box 190 Albemarle NC 280020190/City Manager/704-984-9410/7049849406 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling Dispo: Facility Site Review Compliance Schedules Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Roberto Scheller of Inspector(s) Agency/Office/Phone and Fax Numbers Date 1-DocuSigned by: g�31�2�22 I�vk� �� DWR/MRO WQ/707-235-2204/ "-91 C2A007838943E... Signature of Man Andrew Pitn ®a►tsQn@r1F�viewer Agency/Office/Phone and Fax Numbers Date rA44I4 4/ H P2 !JR/MRO WQ/704-663-1699 Ext.2180/ 9.2.22 F161FB69A2D84A3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 31 NPDES yr/mo/day N C 0024244 111 121 22/08/16 I17 Inspection Type 18 [j (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The current NPDES Permit #NC0024244 was issued on December 1, 2018 and expired on February 28, 2022. A Permit Renewal application was received by the Division dated September 7, 2021. Permit is for continue operation and maintainace of a 12.0 MGD wastewater treatment system. Discharge is via Outfall #001 into Long Creek which is classified as C waters in the Yadkin -Pee Dee River Basin. The subject facility is under Special Order by Consent (EMC SOC WQ S19-007) with modified permit parameters for BOD (Summer/Winter), Ammonia Nitrogen (Summer/Winter), and TSS. Please note that in accordance with SOC WQ S19-007, Item 2. (d), No later than fifteen (15) calendar days after any date identified for accomplishment of any activity listed in 2(a), Table of Scheduled Activity, the City shall submit to the Water Quality Regional Operations Section, Regional Supervisor, written notice of compliance or noncompliance therewith. Please also note that quarterly progress reports detailing the work and activities undertaken and completed on the upgrades to the collection system and WWTP are to be submitted. Flows for the calendar year 2021 were caculated with a yearly average monthly flow of 4.89 MGD or 40.79% of the 12 MGD permitted flow. Flows for calendar year 2020 were caculated with a yearly monthly average flow of 6.247 MGD or 52.05% of the 12 MGD permitted flow. The noted reduction of percent flow may be attritubed to reduced yearly average rainfall during 2021. The average rainfall for the Albemarle area is reported at 48.3 to 47 inches per year. Total rainfall for 2021 was reported at 35.67 inches. Enclosed with this report are copies of 12-month calculated averages for permit parameters. Also attached are graphs of the 12-month averages for BOD (Inf), BOD (Eff), TSS, NH3 as N, Flow, and Fecal Coliform. It was noted that effluent BOD and NH3 as N reflect affect of high flows. The influent BOD graph shows reverse affect of high Flows indicating a reduction in influent BOD by dilution. Compliance history for the 12-month period, July 2021 through June 2022, was reviewed with the following reported violations: 08-2021 09-2021 10-2021 11-2021 12-2021 01-2022 SP-2021-00 SP-2021-0011 SP-2021-0015 SP-2022-0001 SP-2022-0004 SP-2022-0005 Exceeded Monthly Average - TSS Exceeded Weekly/Monthly Average - TSS Exceeded Weekly/Monthly Average - TSS Exceeded Weekly/Monthly Average - TSS Exceeded Weekly Average - TSS Exceeded Monthly Average - TSS At time of inspection records and required information appeared to be well kept and readily available for review. Page# 2 Permit: NC0024244 Inspection Date: 08/16/2022 Owner - Facility: Long Creek WWTP Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new MODE application? Is the facility as described in the permit? • ❑ ❑ ❑ # Are there any special conditions for the permit? • ❑ ❑ ❑ Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: The current permmit became effective on December 1, 2018 and expired on February 28. 2022. Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: Annual Report on line. Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ El El El El • ❑ ❑ ❑ ▪ El El El ❑ ❑ • ❑ Operations & Maintenance Yes No NA NE Page# 3 Permit: NC0024244 Inspection Date: 08/16/2022 Owner - Facility: Long Creek WWTP Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ▪ ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Compliance Schedules Is there a compliance schedule for this facility? Is the facility compliant with the permit and conditions for the review period? Comment: Facility under SOC S19-007. Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Comment: Contract lab. Environment 1 Inc. and Field Lab Certification #5648. Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Grit Removal Type of grit removal a.Manual b.Mechanical Yes No NA NE • ❑ ❑ ❑ ❑ ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ ▪ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ Yes No NA NE • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • Page# 4 Permit: NC0024244 Inspection Date: 08/16/2022 Owner - Facility: Long Creek WWTP Inspection Type: Compliance Evaluation Grit Removal Yes No NA NE Is the grit free of excessive organic matter? Is the grit free of excessive odor? # Is disposal of grit in compliance? Comment: Flow Measurement - Influent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Influent Sampling # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Comment: At time of inspection influent sampler was recorded at 2 degrees C. • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? • ❑ ❑ ❑ Is the wet well free of excessive grease? • ❑ ❑ ❑ Are all pumps present? • ❑ ❑ ❑ Are all pumps operable? • ❑ ❑ ❑ Are float controls operable? ❑ ❑ El • Is SCADA telemetry available and operational? ❑ ❑ • ❑ Is audible and visual alarm available and operational? ❑ ❑ ❑ • Comment: Influent pump station consist of 4 screw lift pumps. Standby Power Yes No NA NE Page# 5 Permit: NC0024244 Inspection Date: 08/16/2022 Owner - Facility: Long Creek WWTP Inspection Type: Compliance Evaluation Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Comment: Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? • ❑ ❑ ❑ Are all pumps present? • ❑ El El Are all pumps operable? • El El El Are float controls operable? • El ❑ ❑ Is SCADA telemetry available and operational? El El • El Is audible and visual alarm available and operational? El El El • Comment: Second lift station consist of 4 screw lift pumps located at secondary treatment. Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Surface Is the basin free of dead spots? • El ❑ ❑ Are surface aerators and mixers operational? • El El El Are the diffusers operational? El El • El Is the foam the proper color for the treatment process? • ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? • ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ El • Is the DO level acceptable?(1.0 to 3.0 mg/I) El ❑ ❑ • Comment: Secondary Clarifier Is the clarifier free of black and odorous wastewater? • Yes No NA NE ❑ ❑ ❑ Page# 6 Permit: NC0024244 Inspection Date: 08/16/2022 Owner - Facility: Long Creek WWTP Inspection Type: Compliance Evaluation Secondary Clarifier Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Comment: Pumps-RAS-WAS Are pumps in place? Are pumps operational? Are there adequate spare parts and supplies on site? Comment: Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ Filtration (High Rate Tertiary) Yes No NA NE Type of operation: Cross flow Is the filter media present? • ❑ ❑ ❑ Is the filter surface free of clogging? • ❑ ❑ ❑ Is the filter free of growth? • ❑ ❑ ❑ Is the air scour operational? El El ❑ ❑ Is the scouring acceptable? • El El El Is the clear well free of excessive solids and filter media? • El ❑ ❑ Comment: Effluent trubid. Disinfection -Gas Are cylinders secured adequately? Are cylinders protected from direct sunlight? Is there adequate reserve supply of disinfectant? Is the level of chlorine residual acceptable? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Page# 7 Permit: NC0024244 Inspection Date: 08/16/2022 Owner - Facility: Long Creek WWTP Inspection Type: Compliance Evaluation Disinfection -Gas Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- - If yes, then when was the RMP last updated? Comment: Yes No NA NE • ❑ ❑ ❑ 1000-0012-3092 De -chlorination Yes No NA NE Type of system ? Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ ❑ • Is storage appropriate for cylinders? ❑ ❑ ■ ❑ # Is de -chlorination substance stored away from chlorine containers? • ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ • ❑ Comment: Sodium Bisulfite used for dechlorination. Are tablet de -chlorinators operational? ❑ ❑ • ❑ Number of tubes in use? Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE El El El El Page# 8 Permit: NC0024244 Inspection Date: 08/16/2022 Owner - Facility: Long Creek WWTP Inspection Type: Compliance Evaluation Effluent Sampling Yes No NA NE # Is proper temperature set for sample storage (kept at less than or equal to 6.0 • ❑ ❑ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ ❑ ❑ representative)? Comment: At time of inspection effluent sampler was recorded @ 5 degrees C. Solids Handling Equipment Is the equipment operational? Is the chemical feed equipment operational? Is storage adequate? Is the site free of high level of solids in filtrate from filter presses or vacuum filters? Is the site free of sludge buildup on belts and/or rollers of filter press? Is the site free of excessive moisture in belt filter press sludge cake? The facility has an approved sludge management plan? Comment: Yes No NA NE ❑ ❑ ❑ ❑ El El El El El El El El El El El El ❑ ❑ ❑ ❑ El El El El El El El El Page# 9