HomeMy WebLinkAboutWQCS00157_Inspection_20220825DocuSign Envelope ID: 56264A9F-74D9-4653-A44A-6C042795530C ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. NORTH CAROLINA Director Environmental Quality August 25, 2022 Eddie Braxton P.O. Box 537 Scotland Neck, NC 27874-0537 Subject: Compliance Evaluation Inspection Scotland Neck Collection System Collection System Permit No. WQCS00157 Halifax County Dear Mr. Braxton: On August 23, 2022, Alys Hannum of the Division of Water Resources (Division) conducted an inspection of the Town of Scotland Neck's (Town) Collection System to evaluate compliance with the operation and maintenance of the subject wastewater collection system permit (WQCS00157). The cooperation and assistance of Bobby Davis, ORC, and Travis Browder, backup ORC, during the inspection were greatly appreciated. The Town's Collection is classified as a CS-2 system. The subject permit is effective from July 9, 2021, until June 30, 2029. Findings during the inspection were as follows: 1. Our records indicate that the wastewater collection system consists of approximately 17.4 miles of gravity sewer, approximately 1.3 miles of force main, 5 duplex pump stations, 6 high priority sewer lines and one high priority manhole (due to repeat mowing incidents). 2. The Town cleaned greater than 10% of its collection system in 2021 (2.2 miles cleaned) and is on -track to clean greater than 10% of its collection system in 2022 with 1.6 miles cleaned. The Town conducts a visual inspection of the entire collection system annually and the inspections are documented. 3. The Town has developed and maintains a complete map of the collection system. Please update the map to include: pipe material, pipe age, and pump station capacity. 4. There have been no reportable sanitary sewer overflows during the most recent two-year period beginning July 2020 and ending July 2022. NORTH CAROLINA Department of Environmental Quality North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 DocuSign Envelope ID: 56264A9F-74D9-4653-A44A-6C042795530C Compliance Evaluation Inspection Scotland Neck Collection System Permit No. WQCS00157 Page 2 of 2 5. An operation and maintenance plan — including pump station inspection, preventative maintenance, and sanitary sewer overflow response — was available and up to date. 6. The Town has a Fats, Oils, and Grease (FOG) program which includes the bi-annual distribution of educational materials to commercial and residential users. The Town is able to take enforcement against users who have not properly installed, operated, and/or maintained grease traps or grease interceptors, or who have otherwise violated the program. 7. The Town's Capital Improvement Plan (CIP) is reviewed and updated annually. The plan covers a period from 2009 to 2027 and is designated for water, wastewater, and collection system improvements. 8. All five pump stations were inspected. All had identification signs, secured access, appeared in good condition and were free of excess debris. All audible and visual alarms functioned when tested. All have connections for portable generators, and none are connected to telemetry. All stations are visited daily, and logbooks are maintained at each station. Pump station maintenance logs were reviewed and appeared satisfactory. 9. The Town's six high priority aerial crossing lines and one high -priority manhole were inspected. The aerial lines appeared straight, rust free, and in good condition. The manhole had no obvious issues. The rights of way for all were being maintained. If you have any questions concerning this report or the required submissions, please contact Vanessa Manuel at vanessa.manuel@ncdenr.gov or by phone at (919) 791-4232. Sincerely, (—DocuSigned by: Uati,t,ssa e. ilkou td, "— B2916E6AB32144F... Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Attachment: EPA Water Compliance Inspection Report cc: RRO Files // Laserfiche Bobby Davis, ORC (bdavis43@embargmail.com) Nancy Deckard, Town Clerk(ndempsey@townofscotlandneck.com) NORTH CAROLINAD_E neparbnent of Environmental Quality North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 DocuSign Envelope ID: 56264A9F-74D9-4653-A44A-6C042795530C Compliance Inspection Report Permit: WQCS00157 Effective: 07/09/21 SOC: Effective: County: Halifax Region: Raleigh Contact Person: Bobby Davis Directions to Facility: System Classifications: CS2, Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Expiration: 06/30/29 Expiration: Title: ORC Certification: NC0023337 Town of Scotland Neck - Scotland Neck WWTP Inspection Date: 08/23/2022 Primary Inspector: Alys K Hannum Secondary Inspector(s): Reason for Inspection: Routine Entry Time 11:OOAM DocuSigned by: 7atiruroisi "-4C22170C5AA04F3... Owner : Town of Scotland Neck Facility: Scotland Neck Collection System PO Box 537 Scotland Neck NC 27874 Exit Time: 02:OOPM 8/24/2022 Phone: 252-886-2387 Phone: Phone: 919-791-4255 Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: Compliant Not Compliant Question Areas: ▪ Miscellaneous Questions II Capital Improvement Plan ▪ Inspections ▪ Lines (See attachment summary) ▪ General ▪ Map ▪ Spill Response Plan ▪ Manholes ▪ Sewer & FOG Ordinances ▪ Reporting Requirements ▪ Spills ▪ Pump Stations Page 1 of 7 DocuSign Envelope ID: 56264A9F-74D9-4653-A44A-6C042795530C Permit: WQCS00157 Owner - Facility:Town of Scotland Neck Inspection Date: 08/23/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: Page 2 of 7 DocuSign Envelope ID: 56264A9F-74D9-4653-A44A-6C042795530C Permit: WQCS00157 Owner - Facility:Town of Scotland Neck Inspection Date: 08/23/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine General Is there a properly designated primary ORC and at least one back-up of proper grade? Are logs being reviewed by the system management or owner on a regular basis? # What is that frequency? # Are there any issues being addressed currently or any in the planning stages? Is there a specific pump failure plan available for all pump stations? Does plan indicate if pump parts/new pumps are in spare parts/equipment inventory? Are new/significantly upgraded pump stations equipped with anti -corrosion materials? Does the permittee have a copy of their permit? # Is permit expiring within the next 6 months? If Yes, has the Permittee applied for renewal? Comment: Sewer and FOG Ordinances Is Sewer Use Ordinance (SUO) or other Legal Authority available? Does it appear that the Sewer Use Ordinance is enforced? Is there a Grease Control Program that legally requires grease control devices? What is the standard grease trap cleaning requirement in the FOG ordinance? Is Grease Control Program enforced via periodic inspections/records review? Is action taken against violators? # Have satellite systems adopted an equivalent or more stringent ordinance? Is grease/sewer education program documented with req'd customer distribution? # Are other types of education tools used like websites, booths, special meetings, etc? If Yes, what are they? (This can reduce mailing to annual.) Comment: Capital Improvement Plan Has a Capital (CIP) or System Improvement Plan been developed and adopted? Is it designated for wastewater only or does it have a dedicated section? Does CIP cover three to five year period of earmarked improvements? Does CIP include description of project area? Does CIP include description of existing facilities? Does CIP include known deficiencies? Does CIP include forecasted future needs? Comment: Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Once per quarter • ❑ ❑ ❑ ❑ • ❑ ❑ • ❑ •❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ 1/month or as needed if more frequent • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 3 of 7 DocuSign Envelope ID: 56264A9F-74D9-4653-A44A-6C042795530C Permit: WQCS00157 Owner - Facility:Town of Scotland Neck Inspection Date: 08/23/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Map Is there a overall sewer system map? Does the map include: Pipe Type (GS/FM) Pipe sizes Pipe materials (PVC, DIP, etc) Pipe location Flow direction Approximate pipe age Pump station ID, location and capacity # Force main air release valve location & type # Location of satellite connections Is the map being updated for changes/additions within 1 year of activation? Comment: Map does not have pipe material, pipe age, or pump station capacity. Reporting Requirements # Have there been any sewer spills in the past 3 years? If Yes, were they reported to the Division if meeting the reportable criteria? If applicable, is there documentation of press releases and public notices issued? Is an Annual Wastewater Performance Report being filed with the Division, if required? Is the report being made available to all its sewer customers? # How is it being made available? Comment: Inspections Are adequate maintenance records maintained? Are pump stations being inspected at the required frequency? # Is at least one complete functionality test conducted weekly per pump station? Is there a system or plan in place to observe the entire system annually? Is the annual inspection documented? # Does the system have any high -priority lines/locations? Are inspections of HPL documented at least every 6 months? Are new lines being added to the HPL list when found or created? Comment: Spill Response Action Plan Is a Spill Response Action Plan available? Is a Spill Response Action Plan available for all personnel? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Website Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Page4of7 DocuSign Envelope ID: 56264A9F-74D9-4653-A44A-6C042795530C Permit: WQCS00157 Owner - Facility:Town of Scotland Neck Inspection Date: 08/23/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Does the plan include: 24-hour contact numbers Response time Equipment list and spare parts inventory Access to cleaning equipment Access to construction crews, contractors, and/or engineers Source of emergency funds Site sanitation and cleanup materials Post-overflow/spill assessment Does the Permittee appear to respond within 2 hours of first knowledge of a spill? Comment: Spills Is system free of known points of bypass? If No, describe type of bypass and location Are all spills or sewer related issues/complaints documented? # Are there repeated overflows/problems (2 or more in 12 months) at same location? # If Yes, is there a corrective action plan? Comment: Lines/Right-of-Ways/Aerial Lines Please list the Lines/Right of Ways/Aerial Lines Inspected: #1 - Hwy 903 East // #2 - Jr High School Road Across from National Guard // #3 - Across from Jr. High School Road // #4 - House Avenue // #5 - Signature Health Care // #7 - 27434 Hwy 125 South Are right-of-ways/easements maintained for full width for access by staff/equipment? If No, give details on temporary access: Is maintenance documented? Are gravity sewer cleaning records available? Has at least 10% of lines older than 5 yrs been cleaned annually? Were all areas/lines inspected free of issues? Comment: Manholes Please list the Manholes Inspected: #6 - Manhole in Ditch on NCSR 1804 next to LS #4 Are manholes accessible? # Are manhole covers/vents above grade? Are manholes free of visible signs of overflow? Are manholes free of sinkholes and depressions? Are manhole covers present? • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ❑ • ❑ ❑ ❑ ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Page5of7 DocuSign Envelope ID: 56264A9F-74D9-4653-A44A-6C042795530C Permit: WQCS00157 Owner - Facility:Town of Scotland Neck Inspection Date: 08/23/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine # Are manholes properly seated? # Are manholes in good condition? # Are inverts in good condition? Is flow unrestricted in manholes? Are manholes free of excessive amounts of grease? Are manholes free of excessive roots? Are manholes free of excessive sand? Are manhole vents screened? Are vents free of submergence? Are manholes free of bypass structures or pipes? Comment: Pump Stations Please list the Pump Stations Inspected: #1, #2, #3, #4, #5 # Number of duplex or larger pump stations in system # Number of vacuum stations in system # Number of simplex pump stations in system # Number of simplex pump stations in system serving more than one building How many pump/vacuum stations have: # A two-way "auto polling" communication system (SCADA) installed? # A simple one-way telemetry/communication system (auto -dialer) installed? For pump stations inspected: Are they secure with restricted access? Were they free of by-pass structures/pipes? Were wet wells free of excessive grease/debris? # Do they all have telemetry installed? Is the communication system functional? Is a 24-hour notification sign posted ? Does the sign include: Owner Name? Pump station identifier? # Address? Instructions for notification? 24-hour emergency contact numbers? Are audio and visual alarms present? Are audio and visual alarms operable? • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE 5 0 0 0 0 0 • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ▪ • ▪ • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ▪ • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page6of7 DocuSign Envelope ID: 56264A9F-74D9-4653-A44A-6C042795530C Permit: WQCS00157 Owner - Facility:Town of Scotland Neck Inspection Date: 08/23/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine # Is there a backup generator or bypass pump connected? If tested during inspection, did it function properly? Is the back-up system tested at least bi-annually under normal operating conditions? # Does it have a dedicated connection for a portable generator? # Is the owner relying on portable units in the event of a power outage? # If Yes, is there a distribution plan? If Yes, what resources (Units/Staff/Vehicles/etc) are included in Plan? # Does Permittee have the approved percentage of replacement simplex pumps? Is recordkeeping of pump station inspection and maintenance program adequate? Do pump station logs include at a minimum: Inside and outside cleaning and debris removal? Inspecting and exercising all valves? Inspecting and lubricating pumps and other equipment? Inspecting alarms, telemetry and auxiliary equipment? Comment: ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 7 of 7