Loading...
HomeMy WebLinkAboutNCC223068_Site Plan or Location Map_20220829Qc 2015 CAJJ, NIXUN & rtNNtUY, INC:. LAPHtJJLY HtJtHVtJ I IJ UUMMUN LAW C:U1'YH1UN 1 ANU U I NLH 1-HUF'tH 1 Y HIUM IJ IN 1MtJt F'LANJ. 1MtJt F'LANJ AHt NU 1 IU tit HtF HUUUC:tU, UNANULU UH UUVItU IN ANY FUHM UH MANNtH WMA1JUtVtH, NUH AHL I MtY IU tit AtR51UNtU 1U ANY IMIHU F'AH I Y WI I MUU I FIHZS I Ut$ IAININ(a I Mt LAI-HtJJtU WHI I ItN I-LHMIJJIUN ANU C:UNJtN I OF t$AJJ, NIXUN & rLNNtUY, INC:. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT TOWN OF MORRISVILLE STANDARDS AND SPECIFICATIONS SYMBOLS AND ABBREVIATIONS ABC AGGREGATE BASE COURSE ALUM ALUMINUM AST2 ALUMINIZED STEEL - TYPE 2 B-B BACK TO BACK BOA BLOW -OFF ASSEMBLY C&G CURB AND GUTTER CFS CUBIC FEET PER SECOND CI CURB INLET CL CENTER LINE CMP CORRUGATED METAL PIPE CO CLEAN OUT COM COMMUNICATION CONC CONCRETE DCV DOUBLE CHECK VALVE DDCV DOUBLE DETECTOR CHECK VALVE DI DROP INLET DIP DUCTILE IRON PIPE EASE EASEMENT ELEC ELECTRIC EX EXISTING FES FLARED END SECTION FH FIRE HYDRANT FM FORCE MAIN FT FEET FT/SEC FEET PER SEC GALV GALVANIZED GV GATE VALVE HDPE HIGH DENSITY POLYETHYLENE L LENGTH LF LINEAR FEET MH MANHOLE PAVE PAVEMENT PE FINISHED PAD ELEVATION PP POWER POLE PVC POLYVINYL CHLORIDE R RADIUS R/W RIGHT-OF-WAY RED REDUCER RCP REINFORCED CONCRETE PIPE RPZ REDUCED PRESSURE ZONE SS SANITARY SEWER STA STATION TDD TEMPORARY DIVERSION DITCH TELE TELEPHONE TSB TEMPORARY SEDIMENT BASIN UG UNDERGROUND WCR WHEELCHAIR RAMP W/L WATER LINE WM WATER METER YI YARD INLET CONSTRUCTION NOTES M EXISTING CURB INLET ❑ EXISTING GRATE INLET/YARD INLET o EXISTING FLARED END SECTION EXISTING FIRE HYDRANT oa-o EXISTING BLOW -OFF ASSEMBLY oa EXISTING GATE VALVE o EXISTING REDUCER ❑ EXISTING WATER METER O EXISTING SAN SEWER MANHOLE o EXISTING CLEAN OUT rOi EXISTING POWER POLE ❑ EXISTING TELEPHONE PEDESTAL EXISTING AREA LIGHT EXISTING SIGN NEW CURB INLET ■ NEW GRATE INLET/YARD INLET on NEW FLARED END SECTION � NEW FIRE HYDRANT H• NEW BLOW -OFF ASSEMBLY H NEW GATE VALVE NEW REDUCER o NEW WATER METER 171 NEW TEE n NEW PLUG • NEW MANHOLE ® NEW CLEAN OUT -r NEW SIGN 0 IRON PIPE BENCHMARK TEMP SILT FENCE CHURCH STREET DAY CARE 1PF 1PF TEMP TREE PROTECTION FENCE TEMP COMBINATION SILT/TREE PROTECTION FENCE TPF TEMP DIVERSION DITCH • DISTURBED LIMITS - • STREAM - - G - - - G EXISTING GAS LINE - - COM - - - COM EXISTING COMMUNICATIONS LINE - - r - - - r EXISTING UNDERGROUND TELEPHONE - - E - - - E EXISTING UNDERGROUND ELECTRIC - - OHE - - - OHE EXISTING OVERHEAD ELECTRIC - - w - - - w EXISTING WATER LINE - - FM - - - FM EXISTING SANITARY SEWER FORCE MAIN - - ss - - - ss EXISTING SANITARY SEWER --------------- EXISTING STORM DRAINAGE NEW STORM DRAINAGE NEW WATER LINE NEW SANITARY SEWER FM NEW SANITARY SEWER FORCE MAIN FM NEW GAS MAIN G G • • • • • • • • • • • • • • • HANDICAPPED ACCESSIBLE ROUTE NOTE: ALL CONSTRUCTION ACTIVITY MUST BE IN ACCORDANCE WITH THE ACCEPTED POLICIES OF THE TOWN OF MORRISVILLE AND NCDOT 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH APPLICABLE MUNICIPALITY STANDARDS, SPECIFICATIONS, AND DETAILS. WORK IN THIS PROJECT SHALL ALSO CONFORM TO THESE PLANS, THE LATEST EDITIONS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION (NCDOT) ROAD AND BRIDGE SPECIFICATIONS, THE ROAD AND BRIDGE STANDARDS, THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL HANDBOOK, THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL REGULATIONS, THE FINAL GEOTECHNICAL REPORT, AND GENERAL DESIGN STANDARDS. IN THE EVENT OF CONFLICT BETWEEN ANY OF THESE STANDARDS, SPECIFICATIONS, OR PLANS, THE MOST STRINGENT SHALL GOVERN. 2. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR TRENCH SAFETY DURING ALL PHASES OF CONSTRUCTION. 3. PER LIDO SECTION 3.8.2.C.6.b, NEW CONSTRUCTION OF A DAY CARE IN AIRPORT OVERLAY-B MUST LIMIT INTERIOR NOISE FROM AIRCRAFT TO AVERAGE DNL OF 45 DB. BUILDING PERMIT APPLICATION MUST INCLUDE CERTIFICATION THAT CONSTRUCTION WILL COMPLY WITH THESE STANDARDS. 4. THE LOCATION AND SIZE OF EXISTING UTILITIES AS SHOWN IS APPROXIMATE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR HORIZONTALLY AND VERTICALLY LOCATING AND PROTECTING ALL PUBLIC OR PRIVATE UTILITIES WHICH LIE IN OR ADJACENT TO THE CONSTRUCTION SITE. AT LEAST 48 HOURS PRIOR TO ANY DEMOLITION, GRADING, OR CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALL NOTIFY THE NORTH CAROLINA ONE -CALL UTILITIES LOCATION SERVICE (ULOCO) AT 1-800-632-4949 FOR PROPER IDENTIFICATION OF EXISTING UTILITIES WITHIN THE SITE. 5. THE CONTRACTOR SHALL SALVAGE AND PROTECT ALL EXISTING POWER POLES, SIGNS, MANHOLES, TELEPHONE RISERS, WATER VALVES, ETC. DURING ALL CONSTRUCTION PHASES. THE CONTRACTOR SHALL REPAIR, AT HIS OWN EXPENSE, ANY EXISTING UTILITIES DAMAGED DURING CONSTRUCTION. 6. TRAFFIC CONTROL ON PUBLIC STREETS SHALL BE IN CONFORMANCE WITH THE TRAFFIC CONTROL PLAN, THE "MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES," AND AS FURTHER DIRECTED BY CITY AND STATE INSPECTORS. 7. ANY DISCREPANCIES FOUND BETWEEN THE DRAWINGS AND SPECIFICATIONS AND SITE CONDITIONS OR ANY INCONSISTENCIES OR AMBIGUITIES IN DRAWINGS OR SPECIFICATIONS SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER, IN WRITING, WHO SHALL PROMPTLY ADDRESS SUCH INCONSISTENCIES OR AMBIGUITIES. WORK DONE BY THE CONTRACTOR AFTER HIS DISCOVERY OF SUCH DISCREPANCIES, INCONSISTENCIES, OR AMBIGUITIES SHALL BE DONE AT THE CONTRACTOR'S RISK. 8. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR SHALL ARRANGE THE MEETING WITH THE CITY ENGINEERING DIVISION. 9. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL REQUIRED PERMITS AND APPROVALS PRIOR TO COMMENCING CONSTRUCTION. 611 & 703 CHURCH STREET TOWN OF MORRISVILLE, WAKE COUNTY, NORTH CAROLINA SITE PLAN AND CONSTRUCTION DRAWINGS 10. ALL AREAS SHALL BE GRADED FOR POSITIVE DRAINAGE, AND AS SHOWN ON THESE PLANS. THE CONTRACTOR SHALL MAINTAIN ADEQUATE SITE DRAINAGE DURING ALL PHASES OF CONSTRUCTION. THE CONTRACTOR SHALL USE SILT FENCES (OR OTHER METHODS APPROVED BY THE ENGINEER AND APPLICABLE MUNICIPALITY) AS REQUIRED TO PREVENT SILT AND CONSTRUCTION DEBRIS FROM FLOWING ONTO ADJACENT PROPERTIES. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE, OR LOCAL EROSION, CONSERVATION, AND SILTATION ORDINANCES. CONTRACTOR SHALL REMOVE ALL TEMPORARY EROSION CONTROL DEVICES UPON COMPLETION OF PERMANENT DRAINAGE FACILITIES AND THE ESTABLISHMENT OF A STAND OF GRASS OR OTHER GROWTH TO PREVENT EROSION. 11. THE CONTRACTOR SHALL CLEAR AND GRUB THE SITE AND PLACE, COMPACT, AND MOISTURE CONDITION ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEER'S SPECIFICATIONS. THE FILL MATERIAL TO BE USED SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. 12. MATERIALS USED TO CONSTRUCT EMBANKMENTS FOR ANY PURPOSE, BACKFILL AROUND DRAINAGE STRUCTURES, OR IN UTILITY TRENCHES FOR ANY OTHER DEPRESSION REQUIRING FILL OR BACKFILL SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST AS SET OUT IN ASTM STANDARD D698. STONE BACKFILL SHALL BE COMPACTED TO 95% MAXIMUM DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST AS SET OUT IN ASTM STANDARD D1557. THE CONTRACTOR SHALL, PRIOR TO ANY OPERATIONS INVOLVING FILLING OR BACKFILLING, SUBMIT THE RESULTS OF THE PROCTOR TEST TOGETHER WITH A CERTIFICATION THAT THE SOIL TESTED IS REPRESENTATIVE OF THE MATERIALS TO BE USED ON THE PROJECT. TESTS SHALL BE CONDUCTED BY A CERTIFIED MATERIALS TESTING LABORATORY AND THE CERTIFICATIONS MADE BY A LICENSED PROFESSIONAL ENGINEER REPRESENTING THE LABORATORY. 13. PROPOSED CONTOURS AND GUTTER GRADIENTS ARE APPROXIMATE. PROPOSED SPOT ELEVATIONS AND ROADWAY PROFILES/SUPERELEVATIONS ARE TO BE USED IN CASE OF DISCREPANCY. 14. THE CONTRACTOR SHALL REVIEW, VERIFY AND COORDINATE ALL DIMENSIONS SHOWN ON PLANS, INCLUDING THE HORIZONTAL AND VERTICAL LOCATION OF CURB INLETS AND GRATE INLETS AND ALL UTILITIES CROSSING THE STORM SEWER PRIOR TO STARTING PROJECT. 15. ALL CURB JOINTS SHALL EXTEND THROUGH THE CURB. MINIMUM LENGTH OF OFFSET JOINTS AT RADIUS POINTS IS 1.5 FEET. ALL JOINTS SHALL BE SEALED WITH JOINT SEALANT. 16. ALL HANDICAP RAMPING, STRIPING, AND PAVEMENT MARKINGS SHALL CONFORM TO ADA REQUIREMENTS AND THE "NORTH CAROLINA STATE BUILDING CODE, VOL. 1-C ACCESSIBILITY CODE. 17. OWNER SHALL PROVIDE FENCING AND OTHER SAFETY MEASURES NECESSARY IN AND AROUND ANY TOWN OF MORRISVILLE PROJECT NO. COMBO=000617=2020 PROPOSED STORMWATER MANAGEMENT MEASURES (PONDS, WETLANDS, ETC.) OBTAINING PROPER PERMITS SHALL BE THE RESPONSIBILITY OF THE OWNER. 18. RETAINING WALLS EXCEEDING 30 INCHES IN HEIGHT SHALL INCLUDE FALL PROTECTION IN THE FORM OF A HANDRAIL OR FENCING ON THE HIGH SIDE OF THE RETAINING WALL. 19. PROPER COMPACTION OF ALL FILL SOILS PLACED ON SITE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. COMPACTION SHALL BE ADEQUATE TO SUPPORT THE PROPOSED USE OF AREAS IN WHICH FILL SOILS ARE PLACED. THE CONTRACTOR SHALL HIRE A GEOTECHNICAL ENGINEER TO TEST AND VERIFY THAT COMPACTION IS ADEQUATE FOR THE PROPOSED USE OF IN THE AREA OF FILL PLACEMENT. 20. ALL ASPECTS OF THIS PROJECT SHALL BE IN FULL COMPLIANCE WITH CURRENT ADA STANDARDS. IF THE CONTRACTOR NOTES ANY ASPECTS OF THE PROJECT WHICH ARE NOT IN COMPLIANCE, THE ENGINEER SHALL BE NOTIFIED PRIOR TO ANY FURTHER WORK BEING PERFORMED. ANY WORK PERFORMED AFTER THE CONTRACTOR NOTES SUCH A NON COMPLIANCE IS SUBJECT TO REMOVAL AND REPAIR AT THE CONTRACTOR'S EXPENSE. 21. THE CONTRACTOR OR OWNER SHALL EMPLOY A GEOTECHNICAL ENGINEER TO TEST ALL EMBANKMENTS AND FILL PLACEMENT FOR PROPER COMPACTION. PROPER COMPACTION SHALL BE PER THE GEOTECHNICAL ENGINEER'S RECOMMENDATIONS OR THESE PLANS, WHICHEVER IS MORE STRINGENT. EMBANKMENTS FOR PONDS SHALL BE PLACED IN 6 INCH LOOSE LAYERS AND SHALL BE COMPACTED TO A DENSITY OF NO LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DENSITY AT A MOISTURE CONTENT OF + OR - TWO PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM D698. THE CONTRACTOR SHALL TAKE PHOTOGRAPHS OF THE OUTLET STRUCTURE AT ALL AT ALL PHASES OF INSTALLATION AND SHALL RETAIN WITH GEOTECHNICAL TESTING DATA. THE CONTRACTOR SHALL ALSO RETAIN ALL SHIPPING RECORDS AND SPECIFICATIONS FOR THE OUTLET STRUCTURE MATERIALS AND STRUCTURES. ALL OF THE ABOVE DATA MAY BE REQUIRED AS PART OF THE MUNICIPALITY AS -BUILT PROCESS AND SHALL BE MADE AVAILABLE TO THE ENGINEER UPON REQUEST. THE CONTRACTOR AND OWNER SHALL HAVE DOCUMENTATION OF THESE TESTS AVAILABLE UPON REQUEST. 22. RETAINING WALLS SHOWN HEREIN SHALL BE DESIGNED BY A QUALIFIED PROFESSIONAL ENGINEER WITH EXPERIENCE DESIGNING RETAINING WALLS. AT LEAST 14 DAYS PRIOR TO BEGINNING CONSTRUCTION OF RETAINING WALLS, THE CONTRACTOR SHALL CONTACT THE OWNER'S GEOTECHNICAL ENGINEER TO SCHEDULE AND COORDINATE ALL APPROPRIATE INSPECTIONS, TESTING, AND VERIFICATION NECESSARY DURING RETAINING WALL CONSTRUCTION. THE GEOTECHNICAL ENGINEER SHALL PROVIDE CONTINUOUS INSPECTION, TESTING AND VERIFICATION FOR THE DURATION OF RETAINING WALL CONSTRUCTION. PROPER SCHEDULING, EXECUTION, AND RECORD KEEPING FOR ALL REQUIRED INSPECTIONS, TESTING, AND VERIFICATION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. SUCH RECORDS SHALL BE RETAINED AND SHALL BE PROVIDED TO THE OWNER AND BASS, NIXON & KENNEDY, INC. ALL MONITORING, TESTING, AND VERIFICATION SHALL CONFORM TO THE MOST RECENT VERSION OF THE NC BUILDING CODE CHAPTER 18, SECTION 1806 OR THE WALL DESIGN ENGINEER'S SPECIFICATIONS, WHICHEVER IS MORE STRINGENT. ��OR4 MUST L I TY \311 Zm ¢� 7 y BEFORE YOU DIG! CONTACT ONE -CALL CENTER 1-800-632-4949 Town of Cary Approved Utility Extensions Water Permit #: WP2200002 Sanitary Sewer Permit #: NP2200002 Reclaimed Water Permit #: N/A By: JAMIE BISSONNETTE, PE OWNER: SMYLE INVESTMENTS, LLC 633 MERCER GRAND DRIVE CARY, NC 27519 CONTACT: KIRIT PADIA PHONE' (9191 749-4447 SHEET INDEX COVER 1 OF 1 EXISTING SURVEY PLAT C6.9 INLET DRAINAGE AREA PLAN COA DEMOLITION PLAN SL1.1 SITE LIGHTING PLAN C0.2 DEMOLITION PLAN SL1.2 STREET LIGHTING PLAN C1.1 SITE PLAN A1.4 ARCHITECTURAL DIMENSION PLAN C1.2 SITE PLAN A4.1 BUILDING ELEVATION C1.3 TURNING MOVEMENT PLAN A4.1 BUILDING ELEVATION FINISH AREAS C2.1 UTILITY PLAN A4.2 BUILDING EXTERIOR LIGHT FIXTURES C2.2 UTILITY PLAN A5.1 PLAYGROUND EQUIPMENT PLAN C3.1 GRADING AND DRAINAGE PLAN A10.1A FIRE EXIT PLAN C3.2 GRADING AND DRAINAGE PLAN A10.1 B FIRE EXIT PLAN C3.3 SCM DETAIL SHEET C4.1 SEWER OUTFALL PLAN & PROFILE C4.2 WATER LINE PLAN & PROFILE C4.3 CHURCH STREET AND DRIVEWAY PROFILE C4.4 CHURCH STREET CROSS -SECTIONS C4.5 CHURCH STREET TYPICAL SECTIONS C5.1 DETAILS C5.2 DETAILS C5.3 DETAILS C5.4 DETAILS C5.5 DETAILS L1.1 LANDSCAPE PLAN L1.2 TREE SURVEY L1.3 TREE PROTECTION PLAN C6.1 EROSION CONTROL PLAN STAGE 1 C6.2 EROSION CONTROL PLAN STAGE 1 C6.3 EROSION CONTROL PLAN STAGE 2 C6.4 NPDES STABILIZATION PLAN C6.5 EROSION CONTROL DETAILS C6.6 EROSION CONTROL DETAILS C6.7 EXISTING DRAINAGE AREA PLAN C6.8 PROPOSED DRAINAGE AREA PLAN TOWN OF MORRISVILLE SITE DATA PROJECT NAME: CHURCH STREET DAY CARE CENTER PIN: (1) 0745-88-5550 (2) 0745-88-6331 ADDRESS: 611/703 CHURCH STREET MORRISVILLE, NORTH CAROLINA ZONING: OFFICE INSTITUTIONAL (0/1) EMAIL: kdpadia@gmail.com USE/OCCUPANCY CLASSIFICATION: EXISTING (1): EXISTING (2): PROPOSED: DEVELOPER: SITE AREA: ROAD FRONTAGE CHURCH STREET SMYLE INVESTMENTS, LLC BUILDING (IM) 633 MERCER GRAND DRIVE NT (SETBACKS: FRONT (5.0% ADMINISTRATIVE ADJUSTMENT): CARY, NC 27519 SIDE: REAR (CODE): REAR (7.0% ADMINISTRATIVE ADJUSTMENT): CORNER SIDE: CONTACT: KIRIT PADIA BUILDING CONSTRUCTION TYPE: DAY CARE CENTER PHONE: (919) 749-4447 BUILDING HEIGHT: PROVIDED: EMAIL: kdpadia@gmail.com DAY CARE CENTER: BUILDING SIZE: REQUIRED PARKING (1 SPACE/325' OF LICENSED AREA): PROVIDED PARKING: STANDARD: ADMINISTRATIVE ADJUSTMENTS COMPACT: ACCESSIBLE INCL X VAN SPACES 1. ADMIN-21-0316: ALTERNATE STANDARDS REQUEST TO UTILIZE TOTAL: CMP PIPE FOR STORM DRAINAGE. 2. ADMIN-21-0317: REDUCTION IN THE PERIMETER LANDSCAPE IMPERVIOUS AREA (REFER TO IMPERVIOUS TABLE FOR DETAIL) BUFFER WIDTH BY 10% LOT COVERAGE: (PROVIDED) 3. ADMIN-22-0374: REDUCTION IN THE FRONT BUILDING SETBACK LOT COVERAGE: (MAXIMUM) BY 5.0%. 4. ADMIN-22-0375: REDUCTION IN THE REAR BUILDING SETBACK BY DISTURBED AREA: 7.0%. COMMON OPEN SPACE (10% REQUIREMENT) SEWER FLOW: ENGINEER: 0.12 GPD/SF (8,531 SF) WATERSHED: - WATER LINES - 6" DIP INC.RECLAIMED LINES: BASS, NIXON & KE N N E DY, CSANITARY SEWER LINES: CONSULTING ENGINEERS 8" PVC 8" DIP 6310 CHAPEL HILL ROAD, SUITE 250 SANITARY SEWER MANHOLES: RALEIGH, NORTH CAROLINA 27607 WATER TAPS: TELEPHONE: (919) 851-4422 SEWER TAPS: FAX: (919) 851-8968 OVERLAY DISTRICT: CERTIFICATION NUMBERS: NCBELS (C-0110) NCBOLA (C-0267) CONTACT: JOHN WOODLIEF, PE EMAIL: John.Woodlief@BNKinc.com SINGLE FAMILY VACANT DAY CARE CENTER 1.09 AC (47,421 SF) 428.53 LF 30' 28.5' 15' 30' 27.9' 20' WOOD NO MAXIMUM 17 FT 8,925 SF 5445 SF/325 = 17 SPACES) 23 SPACES 0 SPACES 2 SPACES 25 SPACES 30,274 SF 63.84% 65.0% 53,231 SF (1.22 AC) REQUIRED: 4,742 SF PROVIDED: 4,763 SF 1,218 GPD NEUSE RIVER 167 LF 0 LF 789 LF 122 LF 7 2 1 AIRPORT OVERLAY B DISTRICT A CARo of ES S/O' 9 Z, •: � 9 SEAL 3 6�6 // ENGINE �'•� ,��:• 4/21 /22 J H H m N Qz a W H Cn cc z 2 W Q U Q H W w oC H Cn 2 cc U N O N 0 M O R:\2019\19202 - Church Street Daycare\CIVIL\04 Construction\001 C0.0 - 19202 Cover.dwg, 4/21/2022 1:43:38 PM, DWG To PDF.pc3 TOWN OF MORRISVILLE PROJECT NO. COMBO-000617-2020 Morrisville Morrisville Reviewed By Reviewed By Engineering Stormwater brg 05/03/2022 CJacobs 05/03/2022