Loading...
HomeMy WebLinkAboutSW8990224_HISTORICAL FILE_19990309STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO SW8 al°1011L. DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS LKl HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD i Stdie of North Carolina Department of Environment and Natural Resources Wilmington Regional Office James B Hunt, Jr , Governor Wayne McDevitt, Secretary Division of Water Quality March 9 1999 Mr IT Mildenberg, President I T M Development 6013 Wellesley Place Wilmington NC 28409 NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject Permit No SW8 990224 Sentry Self Storage High Density Stormwater Project Brunswick County Dear Mr Mildenberg The Wilmington Regional Office received the StormAater Management Permit Application for Sentry Self Storage on February 18, 1999 Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormtiater Regulations set forth in Title 15A NCAC 2H 1000 We are forwarding Permit No SW8 990224 dated March 9, 1999 for the construction of Sentry Self Storage This permit shall be effective from the date of issuance until March 9, 2009 and shall be subject to the conditions and limitations as specified therein Please pay special attention to the Operation and Maintenance requirements in this permit Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems If any parts requirements or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit This request must be tit the form of a written petition, conforming to Chapter 15013 of the North Carolina General Statutes, and filed with the Office of Administrative Hearings PO Drawer 27447, Raleigh, NC 2761 1-7447 Unless such demands are made this permit shall be final and binding If you have any questions or need additional information concerning this matter, please contact Linda Lewis or me at (910) 395 3900 Sincerely, � R4Shiveroqdo Water Quality Regional Supervisor RSS/arl S \WQS\STORMWAT\PERMIT\990224 MAR cc Perry Davis, P E Delaney Aycock, Brunswick County Inspections Linda Lewis Wilmington Regional Office Central Files `r 127 Cardinal fir Ext Wilmington North Carolina 28405 Telephone 910 395 3900 FAX 910 350 2004 An Equal Opportunity Affirmative Action Emplover 50% recycled/10 % post -consumer paper State Stormwater Management Systems Permit No SW8 990224 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO J TM Development Sentry Se f Storage Brunswick County FOR THE construction, operation and maintenance of a detention pond in compliance with the provisions of 15A NCAC 2H 1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit This permit shall be effective from the date of issuance until March 9, 2009 and shall be subject to the following specified conditions and limitations I DESIGN STANDARDS 1 This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data 2 This stormwater system has been approved for the management of stormwater runoff as described on page 3 of this permit, the Project Data Sheet The stormwater control has been designed to handle the runoff from 348,532 square feet of impervious area 3 Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the Perm it 4 The tract will be hmtted to the amount of built -upon area indicated on page 3 of this permit, and per approved plans 2 State Stormwater Management Systems Permit No SW8990224 DIVISION OF WATER QUALITY PROJECT DESIGN DATA SHEET Project Name Sentry Self Storage Perm it Number S W 8 990224 Location Brunswick County Applicant Mr J T Mtldenberg, President Mailing Address J T M DEvelopment 6013 Wellesley Place Wilnungton,NC 28409 Application Date February 18, 1999 Water Body Receiving Stonnwater Runoff Jump and Run Creek (CFR 18-88-9-3-2) Classification of Water Body "SC Sw" If Class SA, chloride sampling results ❑/a Pond Depth, feet 5 Permanent Pool Elevation, FMSL 32 Total Impervious Surfaces, ft2 348,532 Offstte Area entering Pond, ft2 None, per Engineer Requued Surface Area, ft= 24,887 Ptovtded Surface Area, ft2 26,528 Required Storage Volume, ft3 28,180 Provided Storage Volume, ft3 36,886 Temporary Storage Elevation, FMSL 33 3 r_ Controlling Orifice 3"$ pipe 3 State Stormwater Management Systems n PermNo SW8990224 11 SCHEDULE OF COMPLIANCE 1 The stormwater management system shall be constructed in it's entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface except roads 2 During construction, erosion shall be kept to a minunum and any eroded areas of the system will be repaired immediately 3 The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to a Semiannual scheduled inspections (every 6 months) b Sediment removal c Mowing and revegetation of side slopes d Immediate repair of eroded areas e Maintenance of side slopes in accordance with approved plans and specifications f Debris removal and unclogging of outlet structure, orifice device and catch basins and piping g Access to the outlet structure must be available at all tines 4 Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ The records will indicate the date, activity, name of person performing the work and what actions were taken 5 Decorative spray fountains will not be allowed in the stormwater treatment system 6 The facilities shall be constructed as shown on the approved plans This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data 7 Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation Any deviations from the approved plans and specifications must be noted on the Certification 8 A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction 9 Prior to the sale of any portion of the property, an access/mamtenance easement to the stormwater facilities shall be granted in favor of the permittee if access to the stormwater facilities will be restricted by the sale of any portion of the property 10 The permittee is responsible for verifying that the proposed built -upon area does not exceed the allowable built -upon area 1 I The runoff from all built -upon area on the project must be directed into the permitted stormwater control system 12 If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility State Stormwater Management Systems Permit No SW8 990224 13 The following items will require a modification to the permit a Any revision to the approved plans, regardless of size b Project name change c Transfer of ownership d Redesign or addition to the approved amount of built -upon area e Further subdivision of the project area f Filling in, altering, or piping of any vegetative conveyance shown on the approved plan In addition, the Director may determine that other revisions to the project should require a modification to the permit 14 The Director may notify the permtttee when the permitted site does not meet one or more of the minimum requirements of the permit Within the time frame specified in the notice, the permtttee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements The permtttee shall provide copies of revised plans and certification um writing to the Director that the changes have been made III GENERAL CONDITIONS I This permit is not transferable In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate The approval of this request will be considered on its merits and may or may not be approved 2 Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215 6A to 143- 215 6C 3 The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction 4 In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take unnediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems 5 The permtttee grants DENR Staff permission to enter the property for the purpose of inspecting all components of the permitted stormwater management facility 6 The permit may be modified, revoked and reissued or terminated for cause The filing of a request for a permit; modification, revocation and reissuance or termination does not stay any permit condition Permit issued this the 9th day of March, 1999 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Ga- A Preston Howard, Jr , P E , DirectorY Division of Water Quality By Authority of the Environmental Management Commission Permit Number SW8 990224 State Stormwater Management Systems Permit No SW8990224 Sentry Self Storage SIOlmwater Permit No SW8990224 Brunswick County Engineer's Certification t, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full tune) the construction of the project, for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications Noted deviations from approved plans and specification SEAL S i gnatm e Registration Number Date State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original L GENERAL INFORMATION: 1 Applicant's name (specify the name of the corporation, individual, etc who owns the project) J T M Development, Inc 2 Print Owners/Signing Official's name and title (the person who is legally responsible for the facility and its compliance) J T Mildenberg, President 3 Mailing Address for person listed in item 2 above 6013 Wellesley Place City Wilmington State N C Zip 28409 Telephone Number ( 910 ) 392-9303 4 Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc ) Sentry Self Storage 5 Location of Facility (street address) Hwy 211 City Southport County Brunswick 6 Directions to facility (from nearest major intersection) Located on NC Hwy 211 approx 1 mile from the intersection of Hwy 211 & Hwy 133, Long Beach Rd 7 Latitude 39057'24" Longitude 61009'37" of facility 8 Contact person who can answer questions about the facility Name Terry Mildenberg Telephone Number ( 910 ) 392-9303 11. PERMIT INFORMATION. 1 Specify whether project is (check one) X New Renewal Modification 2 If this application is being submitted as the result of a renewal or modification to an existing permit, list the existing permit number and its issue date (if known) Form S W U-101 April 1998 Page] of 4 3 Specify the type of project (check one) Low Density X High Density Redevelop General Permit Other 4 Additional Project Requirements (check appropriate blanks) CAMA Major X Sedimentation/Erosion Control 404 Permit III. PROJECT INFORMATION I In the space provided below, summarize how stormwater will be treated Also attach a detailed narrative (one to two pages) describing stormwater management for the project Stormwater will be treated in a detention pond 2 Stormwater runoff from this project drams to the 3 Total Project Area 18 33 acres 5 How many drainage basins does the project have9 Fear River basin 4 Project Built Upon Area 43 6 % 6 Complete the following information for each drainage basin If there are more than two drainage basins in the project, attach an additional sheet with the information for each basin provided in the same format as below Basin Information Drainage Basin 1 Drainage Basin 2 Receiving Stream Name Jump and Run Creek Receiving Stream Class SC Drama a Basin Area 11 24 ac Existing Impervious* Area 0 Proposed Impervious* Area 8 0 ac Impervious* Area (total) 71 2 % Impervious* Surface Area Drainage Basin I Drainage Basin 2 On -site Buildings 2 96 ac On -site Streets 0 On -site Parking 5 04 ac (parking & driveways) On -site Sidewalks 0 Other on -site 0 Off site 0 Total Z= 8 0 ac • Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc 7 How was the off -site impervious area listed above derived9 Existing topographic maps IV. DEED RESTRICTIONS AND PROTECTIVE COVENANTS Deed restrictions and protective covenants are required to be recorded for all low density projects and all subdivisions prior to the sale of any lot Please see Attachment A for the specific items that must be recorded Form SWU-101 April1998 Page 2of4 - By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the items required by the permit, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot V. AGENT AUTHORIZATION If you wish to designate submittal authority to another individual or firm so that they may provide information on your behalf, please complete this section Designated agent (individual or firm) Cape Fear Engineering, Inc Mailing Address 5040 New Centre Drive, Suite D City Wilmington State N C Zip Phone ( 910 )790-8584 Fax ( 910 )790-8583 VI. SUBMITTAL REQUIREMENTS 28403 This application package will not be accepted by the Division of Water Quality unless all of the appheable items are included with the submittal 1 Please indicate that you have provided the following required information by signing your initials in the space provided next to each item • Origmal and one copy of the Stormwater Management Permit ADmlrcatron Form • One comv of the aoolicable Suomlement Form(s) for each BMP (see Attachment A) • Permit anolrcatron mrocessurg fee (see Attachment A) • Detailed narrative descrimtron of stormwater treatment/management • Two comes of Dlans and smecrfrcatrons mcludmg - Development/Project name - Engineer and firm - Legend - North arrow - Scale - Revision number & date - Mean high water line - Dimensioned property/project boundary - Location map with named streets or NCSR numbers - Original contours, proposed contours, spot elevations, finished floor elevations - Details of roads, parking, cul-de-sacs, sidewalks, and curb and gutter - Wetlands delineated, or a note on plans that none exist - Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations - Drainage basins delineated - Vegetated buffers (where required) VH. APPLICANT'S CERTIFICATION 1, (print or type name ofperson listed in General Information, item 2) J T Mildenberg certify that the information included on this permit application form is correct, that the project will be constructed in conformance with the approved plans, that the deed restrictions in accordance with Attachment A of this form will be recorded with all r r ermit conditions, and that to the best of my knowledge the proposed project�neq�l{es wrthye rerW 15A NCAC 2H 1000 Signature Title President Form SWU-101 April 1998 Page 3 of Date 2 /7 99 ATTACHMENT A 1. Deed Restriction Requirements The following statements must be recorded for all low density projects and for all projects that involve the subdivision and selling of lots or outparcels 1 No more than square feet of any lot, including that portion of the right-of-way between the edge ofpavement and the front lot line, shall be covered by impervious structures, including asphalt, gravel, concrete, brick, stone, slate or similar material but not including wood decking or the surface of swimming pools This covenant is intended to insure continued compliance with the stormwater permit issued by the State of North Carolina The covenant may not be changed or deleted without the consent of the State No one may fill in, pipe, or alter any roadside swale except as necessary to provide a minimum driveway crossing NOTE If lot sizes vary significantly, the owner/developer must provide an attachment listing each lot number, size, and the allowable built -upon area for each lot For commercial projects that have outparcels or future development the following statements must also be recorded 3 The connection from the outparcel or future area into the stormwater system must be made into the forebay such that short -circulating of the system does not occur 4 All built -upon area from the outparcel or future development must be directed into the permitted stormwater control system Built -upon area in excess of the permitted amount will require a permit modification prior to construction For curb outlet systems, the following statement in addition to items 1 and 2 above must be recorded 6 No one may pipe, fill on or alter any designated 100 foot long grassed swale used to meet the requirements ofNCAC 211 1008(g) 2. Supplement Forms The applicable supplement form(s) listed below must be submitted for each BMP specified for this project Form SWU-102 Wet Detention Basin Supplement Form SWU-103 Infiltration Basin Supplement Form SWU-104 Low Density Supplement Form SWU-105 Curb Outlet System Supplement Form SWU-106 Off -Site System Supplement Form SWU-107 Underground Infiltration Trench Supplement Form SWU-108 Neuse River basin Nutrient Management Strategy Supplement 3. Permit Application Fees (check made payable to NCDENR and submitted to the appropriate Regional Office) Type of Permit New, Modification, or Timely Renewal Without Late Renewal Modification Low Density High Density Other Director's Certification General Permit Form SWU-101 April1998 $225 n/a $385 $225 $225 n/a $350 n/a $50 n/a Page 4 of 4 r� Permit No 5L.�9�r1�1 Z (to be provided y WQJ State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM WET DETENTION BASIN SUPPLEMENT This form may be photocopied for use as an original DWQ Stormwater Management Plan Review A complete stormwater management plan submittal includes a wet detention basin supplement for each basin, design calculations, plans and specifications showing all basin and outlet structure details, and a signed and notarized operation and maintenance agreement I. PROJECT INFORMATION (please complete the following information) Project Name 5 E,.f S!oW 6L t-- Contact Person Phone Number (�jO) For projects with multiple basins, specify which basin this worksheet applies to Basin Bottom Elevation 0,20 ft (average elevation of the floor of the basin) Permanent Pool Elevation 30 o ft (elevation of the onfice) Temporary Pool Elevation 33 27 ft (elevation of the discharge structure overflow) Permanent Pool Surface Area Zvi 5Zg sq ft (water surface area at the onfice elevation) Drainage Area // Z4 ac (on -site and off -site drainage to the basin) Impervious Area $ o ac (on -site and off -site drainage to the basin) Permanent Pool Volume 97, 91 I cu ft (combined volume of main basin and forebay) Temporary Pool Volume 5&. 90(, cu ft (volume detained above the permanent pool) Forebay Volume �_�144-o2 cu ft SA/DAI used 6670 (surface area to drainage area ratio) Diameter of Onfice 5 in Design TSS Removal �62 % (85% TSS removal required, see item k below) II. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N C Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section 15 A NCAC 2H 1008 Initial in the space provided to indicate the following design requirements have been met and supporting documentation is attached If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below If a requirement has not been met, attach justification. Form SWU-102 Rev I/August 1998 Page 1 of a The temporary pool controls runoff from the 1 inch storm event b The basin length to width ratio is greater than 3 1 c The basin side slopes above the permanent pool are no steeper than 3 1 d A submerged and vegetated perimeter shelf at less than 6 1 is provided (show detail) e Vegetation above the permanent pool elevation is specified f An emergency drain is provided to empty the basin g The permanent pool depth is between 3 and 6 feet (required minimum of 3 feet) h The temporary pool draws down in 2 to 5 days i A trash rack is provided for both the overflow and onfice j The forebay volume'is approximately equal to 20% of the total basin volume Agt — k Sediment storage is provided in the permanent pool A 30-foot vegetative filter is provided at the outlet2 (include erosive flow calculations) Recorded drainage easement for each basin including access to nearest right-of-way A site specific operation and maintenance (O&M) plan is provided A vegetation management/mowing schedule is provided in the O&M plan Semi-annual inspections are specified in the O&M plan A debris check to be performed after every storm event is specified in the O&M plan Specific clean -out benchmarks are specified in the O&M plan (elevation or depth) A legally responsible party is designated in the O&M plan3 (include name and title) If the basin is used for sediment and erosion control during construction, clean out of the basin is specified to be performed prior to use as a wet detention basin Footnotes i When using the Division SA/DA tables, the correct SA/DA ratio for permanent pool sizing should be computed based upon the actual impervious % and permanent pool depth Linear interpolation should be employed to determine the correct value for non- standard table entries 2 The requirement for a vegetative filter may be waived if the wet detention basin is designed to meet 90% TSS removal 3 The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president III. WET DETENTION BASIN OPERATION AND MAINTENANCE AGREEMENT The wet detention basin system is defined as the wet detention basin, forebay, non-integrated pretreatment systems (pretreatment other than forebays), and the vegetated filter if one is provided This system (check one) ❑ does does not incorporate a vegetated filter. This system (check one) ❑ does $does not incorporate non-integrated pretreatment. Maintenance activities shall be performs as follows After every significant runoff producing rainfall event and at least monthly Form SWU-102 Rev 1/August 1998 Page 2 of 3 a, `Inspect the wet detention basin system for sediment accumulation, erosion, trash accumulation, grass cover, and general condition b Check and clear the onfice of any obstructions such that drawdown of the temporary pool occurs within 2 to 5 days Repair eroded areas immediately, re -seed as necessary to maintain good vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash as needed Inspect and repair the collection system (i e catch basins, piping, swales, riprap, etc ) quarterly to maintain proper functioning 4 Remove accumulated sediment from the wet detention basin system semi-annually or when depth is reduced to 75% of the original design depth Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i e stockpiling near a wet detention basin or stream, etc ) The original design depth is 5i' c7 The sedimentremoval benchmark epth is 5 Remove cattails and other indigenous wetland plants when they cover 75% of the basin surface These plants shall be encouraged to grow along the basin perimeter 6 If the basin must be drained for an emergency or to perform maintenance, the flushing of sediment through the emergency drain shall be minimized to the maximum extent practical All components of the wet detention basin system shall be maintained in good working order I acknowledge and agree by my signature below that I am responsible for the performance of the above maintenance procedures I agree to notify DWQ of any problems with the system or changes in the name of the project, responsible party, or address Print nar. Address Phone _ Title SignE Date a5 I> /, •�T�fm-Jr/ E. �1 GLS a Notary Public for the State of -' Countyof do hereby certify that personally appeared before me this day of %r_'i3r'vs ��/ 19��, and acknowledge the due execution of the forgoing infiltration syst fp maintenance requirements Witness my hand and official seal, n My Form SWU-102 Rev 1/August 1998 Page 3 of 3 GNY e%, phi f ^. _? . ' NOTARY PUBLIC ' c r°11tiga0 ®ER�Debs`"1 5040 New Centre Dr, 5ulte 0 Wilmington, NC 2&403 TEL (910) 790-5554 FAX (910) 790-85&3 OW4,61lsouth net Mrs Linda Lewis NC DWQ 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Re: Sentry Self Storage Dear Linda, Fecruary 19, 1999 Please find attached a check for $35 00 to be added to the check for $385 00 that was submitted to you on February 18`h for the above named project This should bring us in line with the new permitting fee of $420 00 Should you have any questions or comments please feel free to contact me at 790-8584 rills, CPESC Manager cc J T Mildenberg, President File 800-05 CAPE FEAR Engineering, Inc_ �i�„�° 4�/ 5040 New Centre Drive Suite D Wilmington N C 28403 Voice (910) 790-8584 Fax (910) 790-8583 E-mail cfe@beffsouth net To NCDENR WATER QUALITY SECTION Cardinal Drive Extension ATTENTION LINDA LEWIS 1'ransmittal DATE 2-18-99 PROJECT NO 800-05 RE Sentry Self Storage Southport, NC Quantity Drawing No Description 3 Storm water application and supporting supplemental documents (1 original & 2 copies) 3 Design Narrative 3 Storm water plan 1 Check in the amount of $385 00 REMARKS CC J T Mildenberg File 800-05 "30" Signed ✓ v Andy Md s, Project Manager Design Narrative For Sentry Self Storage Brunswick County, North Carolina Prepared for J T M Development, Inc 6013 Wellesley Place Wilmington, North Carolina 28409��®���%+�%�A ��� (910) 392-9303 N Date February 17, 1999 Prepared by Cape Fear Engineering, Inc 5040 New Centre Drive, Suite D Wilmington, North Carolina 28403 (910)790-8584 D E C E I V E FEB 1 81999 D D E M PRO.) p 4�2- z 2-1�7•,=tcj I{1111111!!/ff,PP �''''. ?� ,FESSJp � SEAL 20563 G DESIGN NARRATIVE 1. GENERAL: The project site is located along Hwy 211 approx 1 mile from the intersection of Hwy 211 and Hwy 133 (Long Beach Road) in Southport, North Carolina, Brunswick County The project area is approximately 18 33 acres Drainage considerations are to be in accordance with DEM stormwater requirements The intent of this project is to develop buildings and parking for a commercial development which will consist of office space and self storage units 2. EXISTING SITE Site topography in the area is relatively flat with slopes typically less than one (1) percent The site has an existing ditch on the east and west property lines which drams to the south end of the property towards Jump and Run creek In areas left undisturbed, vegetation consists primarily of grasses and minor ground cover within the area of the unprovements Subsurface soils are typically a mixture of sands, silty sands and organics 3. PROPOSED IMPROVEMENTS: Improvements proposed include the construction of a subsurface drainage system that will collect and carry stormwater to a wet detention pond at the southern end of the property behind the proposed buildings In the first phase of the project there will be (2) two self storage buildings and (2) two office buildings along with paved driveways and parking Phase two will consist of the remainder of the three buildings and parking areas along with subsurface drainage as shown on the attached plan The design of the detention pond has been based on the phase one and two impervious coverage, and will be built during phase one to the designed dimensions for both phases 4. DRAINAGE CALCULATION CONSIDERATIONS Drainage calculations have been provided for the subsurface drainage system and the wet detention pond (See attached) No 5505 Engineels Computation Pad c FA N a o V' Fo 40- pa� I� GA�.GiIL�Tf�I��: "L 7j 3Z,o Z6,5zs Z3,9S8 31.0 Z // 084 19, (pOZ 30,0 /8, 540 /7/ 4Z4 Z 9,0 /�, zzc /S Z4(D 2 8•D /3, SOS' / l/ 74 1 27.0 D,gzo 3Z a 33 3 OIL Vbl_AVA Z z8 zZo 87, 7�1 � T 3 > Z8, lb �t tv3 3Z,6 i��, Milo. IN ro a c 0 ro a E 0 U ♦5 ,-� Z- o►�-r-Fi cc -r o ►� o l� C�.1 r� - I� \/OLLII`i-E 2 Qol, = 36,88(o � , r ,41riArt=3618ge. 6?HAX =O.zi3 64:�'' �A-.,Erac,EE Inc.) u-�F- 31 11 irls'lPF 4 �pPc-7 rbe crz,n6E —35. ara,- -33.3 P, FT'_ 5319 = 2. 2 5 D�(� r/ o I�- o./c) j�F5 bXo-049 6? PERM R. n m JS ca a c 0 L2,{ e5lzF-: 'Ib II � ZO`10 o �AS�N VOL-0M5 T'� Von k2ea D sir 5a v� Qj r1 E 32o 9 �� 61 53� 31.0 S, 6So s, ZZ7 - 30.0- - `1, 790 -- ZS•o 329S _ I Oz t 3 G oz s7,5ci/ En 5505 Engineers Computation Pad I G II J � r � W r nW m O y £ .1= o ;V n ,, ,i v D rj C3 . O N D TO LA -o It � � D N 70 d p� 0 b � ilk U ry P nY „ , O �9 N C" U� 1 Io a, ro AN a O 0 � � I w (I� w = p� C�l c Plan View cB�lz Gp�s„ catsq t B # �ZY t a s*l3 20 18 GgN6 17 c 8 ►3 1 23 22 cape 16 c¢?%'17 24' 6 5 c6s<S Ggsl! 4 15 c BsszgB 11 9 Cgp7 3 CBgy 2 CB#t 13 ea;rl? 11 G3stlr 1 cl3rrzl FrS2 12 10 14 [Stta� C8ls'19 G6scl6 Proj file P1-SD-A STM OF file BRUNCO OF No Lines 24 02-18-1999 Storm Sewer Tabulation Page 1 Line Line ID Incr Rnofl Incr Sum Tc Rnfal Total Add Total Capac Line Line Line Veloc Veloc HGL HGL Invert Invert One 0 Area coeff CA CA Irian runoff flow flow @full size length slope up down up down up down line (ac) (C) (min (In/hr (cfs) (cfs) (eta) (cfs) (In x In) (ft) (W (its) (fUs) (ft) (ft) (ft) (ft) # 1 FES#1-CB#1 014 090 013 492 125 597 294 00 294 718 48 c 133 025 24 23 3205 3200 2833 2800 0 2 CB#1-CB#4 024 090 022 308 102 631 195 00 195 333 36 c 165 025 31 28 3224 3214 2975 2933 1 3 CB#4-CB#7 022 090 020 286 92 645 185 00 185 333 36 c 165 025 31 28 3248 3239 3016 2975 2 4 CB#7-CB#ll 017 090 015 266 86 656 175 00 175 333 36 c 110 025 30 28 3270 3264 3043 3016 3 5 CB#11-CB#14 014 000 000 251 76 672 169 00 169 333 36 c 173 025 32 28 3295 3284 3086 3043 4 6 CB#14-CB#17 012 090 010 204 71 681 139 00 139 204 30 c 121 025 41 38 3329 3311 3166 3136 5 7 CB#17-CB#20 024 090 021 130 66 691 90 00 90 113 24 c 124 025 39 39 3384 3355 3248 3217 6 8 CB#20-CB#23 052 090 047 047 50 722 34 00 34 53 18 c 81 025 27 24 3419 340E 3318 3298 7 9 CB#14-CB#15 031 090 028 047 60 702 33 00 33 52 18 c 84 025 31 38 3346 3311 3257 3237 5 10 CB#15-CB#16 021 090 019 019 50 722 14 00 14 18 12 c 164 025 21 33 3425 3360 3348 3308 9 11 CB#17-CB#18 050 090 045 063 63 696 44 00 44 40 18 c 84 015 31 41 3393 3355 3279 3267 6 12 CB#18-CB#19 021 090 019 019 50 722 14 00 14 14 12 c 164 015 20 21 3434 3407 3354 3329 11 13 CB#2D-CB#21 048 09D 043 062 60 703 44 00 44 33 18 c ill 010 28 31 3433 34 OB 3309 3298 7 14 CB#21-CB#22 021 090 019 019 50 722 14 00 14 11 12 c 111 010 19 19 3461 3445 3370 3359 13 15 CB#1-CB#2 015 090 014 1 71 122 601 103 00 103 120 24 c 64 028 35 34 3225 3214 3051 3033 1 16 CB#2-CB#3 Oil 090 010 133 118 608 81 00 81 120 24c 74 02B 27 26 3251 3244 3072 3051 15 17 CB#3-CB" 019 090 017 124 107 623 77 00 77 120 24 c 165 028 28 25 3279 3263 3118 3072 16 18 CB#6-CB#9 010 090 009 107 97 638 68 00 68 120 24 c 165 028 29 24 3305 3291 31 64 31 18 17 19 CB#9-CB#10 009 090 008 025 67 688 1 7 00 1 7 19 12 c 34 028 28 38 3347 3320 3274 3264 18 20 CB#10-CB#12 019 090 017 017 50 722 1 2 00 12 19 12 c 220 02B 25 1 7 3396 3359 3335 3274 19 21 CB#9-CB#8 023 090 021 072 95 642 47 00 47 56 18 c 47 028 35 36 3332 3318 3227 3214 18 22 CB#8-CB#13 030 090 027 052 77 671 35 00 35 47 18 c 255 020 27 22 3382 3352 3278 3227 21 PROJECT FILE PI -SD -A STM I-D-F FILE NHCO IDF TOTAL NUMBER OF LINES 24 RUN DATE 02-18-1999 NOTES c = circular, e = elliptical, b = box, Intensity = 137 2656 / (Tc + 25 50006) A 8617154, Return period = 10 Yrs Storm Sewer Tabulation Page 2 Line Line ID Incr Rno Incr. Sum Tc Rnfal Total Add Total Capac Line Line Line Veloc Veloc HGL HGL Invert Invert Dns # Area coeff CA CA Inten runoff flow flow @ full size length slope up down up down up down line (ac) (C) (min (In1hr (cis) (cfs) (cfs) (cfs) (in x In) (it) IN (flls) (its) (it) (it) (it) (it) # 23 CB#13-CB#24 027 090 025 025 50 722 18 00 18 41 18 c 235 015 16 1 2 3404 3393 3314 3278 22 24 CB#2-CB#5 026 090 023 023 50 722 1 7 00 1 7 25 12 c 165 050 31 38 3399 3306 3334 3251 15 PROJECT FILE P1-SD-A STM I-D-F FILE NHCO IDF TOTAL NUMBER OF LINES 24 RUN DATE 02-18.1999 NOTES c = circular, a = elliptical, b = box, Intensity = 137 26561(Tc + 25 50006) A 8617154, Return period = 10 We Plan View GB#37 G8ar34 G3sr31 G81t�,r 6 cesz3c 13 5 12 [B 6 c30-3';t 3 Cf3 #29 2 9 7 1 F'ps 3s ;x 4 10 tl3rx33 c3�8 11 cB4 ;t7 LBsr36 $ Gl3#3S Proj file P2-SDA STM OF file BRUNCO OF No Lines 13 02-18-1999 Storm Sewer Tabulation Page 1 Line Line ID Incr Rno Incr Sum Tc Finial Total Add Total Capac Line Line Line Veloc Veloc HGL HGL Invert Invert Dns C Area eceff CA CA Inten runoff flow flow @ full size length slope up down up down up down line (ac) (C) (min (INhr (cfs) (cfs) (cfs) (cfs) (in z In) (ft) (°/.) (ftlsJ (ftls) (ft) (ft) (ft) (ft) # 1 FES#2-CB#26 012 090 011 236 94 643 152 00 152 290 30 c 47 050 32 31 3054 3050 2824 2800 0 2 CB#26-CB#29 020 090 018 159 87 655 104 00 104 160 24 c 165 050 44 33 3098 3070 2956 2874 1 3 CB#29-CB#32 012 090 011 141 80 666 94 00 94 160 24 c 165 050 50 33 3154 3128 3039 2956 2 4 CB#32-CB#33 015 090 013 013 50 722 09 00 09 25 12 c 54 050 31 22 3207 3192 3166 3139 3 5 CB#32-CB#31 014 090 012 116 77 671 78 00 78 160 24 c 54 050 36 30 3195 3192 3066 3039 3 6 CB#31-CB#34 029 090 026 104 75 675 70 00 70 160 24 c 43 050 32 28 3217 3215 3087 3066 5 7 CB#34-CB#35 017 090 015 078 67 689 54 00 54 160 24 c 147 050 41 22 3248 3234 31 60 3087 6 8 CB#35-CB#36 028 090 025 063 62 698 44 00 44 62 18 c 112 035 34 46 3352 3291 3250 3210 7 9 CB#36-CB#37 042 090 038 038 50 722 27 00 27 58 18 c 164 030 26 18 3385 3371 3299 3250 8 10 CB#26-CB#27 014 090 012 034 61 700 24 00 24 25 12 c 54 050 32 31 3090 3070 3000 2974 1 11 CB#27-CB#28 024 090 022 022 50 722 1 6 00 16 25 12 c 165 050 30 20 3146 3106 3083 3000 10 12 CB#26-CB#25 013 090 012 032 61 700 22 00 22 25 12 c 54 050 31 29 3087 3070 3000 2974 1 13 CB#25-CB#30 022 090 020 020 50 722 14 00 14 25 12 c 165 050 31 18 3141 3102 3083 3000 12 PROJECT FILE P2-SDA STM I-D-F FILE BRUNCO OF TOTAL NUMBER OF LINES 13 RUN DATE 02-18-1999 NOTES c = circular, e = e111ptical, b = tax, Intensity = 137 26561(Tc + 25 50006) A 8617154, Retum period = 10 Yrs W i=T i�o tits Legend Runoff Combined • Channel Reach Pond Route Proi file WETPOND GPW IDF' file BRUNCO OF 2 h dro ra hs 02-18-1999 Hydrograph Summary Report Page 1 Hyd No Hydrograph type (origin) Peak now lots) Time Interval (min) Time to peak (min) Volume (acft) Return period (yrs) Inflow hyd(s) Maximum elevation (it) Maximum storage (acft) Hydrograph description 1 Rational 451 1 15 093 10 -- -- Wet Pond Inflo 2 Reservoir 10 1 30 020 10 1 3340 092 Pond routing Proj file WETPOND GPW OF file BRUNCO OF Run date 02-18-1999 Hydrograph Report Page , Hyd. No. 1 Wet Pond Inflow Hydrograph type Storm frequency Drainage area Intensity I-D-F Curve = Rational = 10 yrs = 11 24 ac = 5 65 in/hr = BRUNCOIDF Hydrograph Discharge Table Time -- Outflow, (hrs cfs) 020 3610 022 3911 023 4212 025 45 12 << 027 4212 028 3911 030 3610 End Peak discharge = 45 12 cfs Time Interval = 1 min Runoff coeff = 71 Time of conc (Tc) = 15 min Reced limb factor = 1 Total Volume = 40,612 cult, 093 aclt Hydrograph Report Page , Hyd. No. 2 Pond routing Hydrograph type = Reservoir Storm frequency = 10 yrs Inflow hyd No = 1 Max Elevation = 33 40 ft Peak discharge = 1 04 cfs Time Interval = 1 min Reservoir name = Wet Pond Max Storage = 0 92 acft Sbmge Ind"bon mMod used Total Volume = 8,603 cuff, 0 20 acft Hydrograph Discharge Table Time Inflow Elevation Culv A Culy B Culy C Weir A Weir B Weir C Outflow (hrs) (cfs) (ft) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 042 1504 3334 007 — — 035 -- ---- 042 043 1203 3336 007 — — 058 — -- 066 045 903 3338 007 — — 076 — — 084 047 602 3339 007 — -- 089 — — 096 048 301 3340 007 — — 095 — -- 1 03 050 000 33 40 << 007 — -- 097 -- -- 1 04 << 052 000 3340 007 — -- 094 — -- 1 01 053 000 3340 007 — — 092 — — 099 055 000 3340 007 — -- 090 — -- 098 057 000 3339 007 — — 089 — — 096 058 000 3339 007 — -- 087 — -- 094 060 000 3339 007 -- -- 085 -- -- 092 062 000 3339 007 — — 083 — — 091 063 000 3339 007 — — 082 — — 089 065 000 3338 007 — — 080 — — 087 067 000 3338 007 — — 079 — -- 086 068 000 3338 007 — --- 077 — -- 084 070 000 3338 007 — — 076 -- --- 083 072 000 3338 007 — — 074 — — 081 073 000 3338 007 — — 073 — — 080 075 000 3337 007 — — 071 — — 078 077 000 3337 007 — -- 070 — — 077 078 000 3337 007 — — 068 -- --- 075 080 000 3337 007 — — 067 — — 074 082 000 3337 007 — — 066 — — 073 083 000 3337 007 — — 064 — — 071 085 000 3337 007 — — 063 — — 070 087 000 3336 007 — -- 062 — --- 069 088 000 3336 007 — — 060 -- — 068 Pond routing Hydrograph Discharge Table Time Inflow Elevation (hrs) (cfs) (ft) 1 02 000 3335 1 03 000 3335 1 05 000 3335 1 07 000 3335 1 08 000 3335 1 10 000 3335 1 12 000 3335 1 13 000 3335 1 15 000 3335 1 17 000 3334 1 18 000 3334 1 20 000 3334 122 000 3334 1 23 000 3334 1 25 000 3334 1 27 000 3334 128 000 3334 1 30 000 3334 1 32 000 3334 1 33 000 3334 1 35 000 3333 1 37 000 3333 1 38 000 3333 1 40 000 3333 1 42 000 3333 1 43 000 3333 145 000 3333 147 000 3333 1 48 000 3333 1 50 000 3333 1 52 000 3333 1 53 000 3333 1 55 000 3333 1 57 000 3333 1 58 000 3333 1 60 000 3332 162 000 3332 163 000 3332 1 65 000 3332 1 67 000 3332 Page 2 Culy. A Culy B CUIV C Weir A Weir B Weir C Outflow (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 007 — — 051 — — 058 007 — — 050 — — 057 007 — — 049 — — 056 007 — — 048 — — 055 007 — — 047 — — 054 007 — — 046 — — 053 007 — — 045 — — 052 007 — — 044 — — 051 007 — — 043 — — 050 007 — — 042 — — 049 007 — — 041 — — 048 007 — — 040 — — 048 007 — — 040 — — 047 007 — — 039 — — 046 007 — — 038 — — 045 007 — — 037 — — 044 007 — — 036 — — 043 007 — — 035 — — 043 007 — — 035 — — 042 007 — — 034 -- — 041 007 — — 033 -- — 040 007 — — 032 — — 040 007 — — 032 — — 039 007 — — 031 — — 038 007 — — 030 — — 037 007 — -- 030 --- — 037 007 — — 029 — -- 036 007 — — 028 — — 035 007 — — 028 — — 035 007 — — 027 — — 034 007 — — 026 — — 033 007 — — 026 — — 033 007 — — 025 — — 032 007 — — 025 — — 032 007 — — 024 — — 031 007 — — 023 — — 031 007 — — 023 — — 030 007 — — 022 — — 029 007 — — 022 — — 029 007 — — 021 — — 028 DEC 2 8 1998 J T M Development Inc 6013 Wellesley Place Wilmington N C 28409 910-392-9303 910-793-4808 fax To, Lmda Lewis Environmental Engineer North Carolina Dept of Environment And Natural Resources 127 Cardinal Dr Ext Wilmington NC 28405 Subject, Stormwater Project No S W8 981207 Dear Linda Lewis, In reference to your letter of Dec 2 1998, please be advised that at this time we are only clearing this property so a topo can be done As soon as a topo is done we will be able to do the plans necessary for a Stormwater Permit Application At this time a topo is scheduled to begin on or about the first of the year I will keep your office advised of our progress and I will be in to get the necessary forms Thank you fo yo p J Terry Mildenberg president TRANSMISSION VERIFICATION REPORT DATE J I ME FAX NO /NAME DURATION PAGE(S) RESULT MODE 28-99 --14 A09 �64808 STANDARD TIME 12/28/1998 09 25 NAME NCDENR WIRO FAX 910-350-2004 TEL 9103502004 TRANSMISSION VERIFICATION REPORT DATE DIME FAX 110 /NAME DURATION PAGE(S) RESULT MODE ,I-CS-24 9zl534805 e0 00 Of< STANDARD TIME 12/28/1998 09 25 NAME NCDENR WIRO FAX 910-350-2004 TEL 9103502004 CERTIFIED MAIL NZ 153 115 216 RETURN RECEIPT REQUESTED Mr J T Mildenberg, President JTM 6013 Wellesley Place Wilmington, NC 28409 Subject Dear Mr Mildenberg December 2,1998 REQUEST FOR STORMWATER MANAGEMENT PERMIT APPLICATION JTM Commerical Development Stormwater Project No SW8 981207 Brunswick County On December 1, 1998, the Wilmington Regional Office received a copy of the Notice of Receipt Of Erosion & Secimentation Control Plan for JTM Commerical Development The North Carolina Administrative Code requires any project that must receive either a Sedunentation and Erosion Control Plan permit and/or a CAMA major permit to apply for and receive a Stormwater Management Permit by the Division of Water Quality Any construction on the subject site, prior to receipt of the required permit, will constitute a violation of 15A NCAC 2H 1000 and may result in appropriate enforcement action by this Office Either a Stormwater Permit Application Package including 2 sets of plans, completed application form, fee, and supporting documentation, or a written response regarding the status of this project and the expected submittal date must be received in this Office no later than January 2, 1999 Failure to respond to this request may result in the initiation of enforcement action, and construction may experience a subsequent delay Please reference the Project Number above on all correspondence. If you have any questions, please call me at (910)-395-3900 Sincerely, bn3,170l s1617ecl b Linda Lewis Environmental Engineer RSS/arl S \WQS\STORMWAT\STORMSUB\981207 Dec cc Delaney Aycock, Brunswick County Inspections Linda Lewis Central Files Post -it® Fax Note 7671 Date 12 Z(� 1 g Pages fc To err t clen From L _ _ 11Z /IC L Qc,4l Co /Dept - S-rH ff �� Co Phone #1�n Phone # 3ci5 _1 l 'JJ' qDC) _( Fax # �] Q Q Fax # }Z 153 115 216 US Postal Service Receipt for Certified Mad No Insurance Coverage Provided Uo not use for International Mall See reverse St at & Nyippy wt otfp late,& ZIP Coda v A �� Postage .s / Z Cedtfied Fee �J Specal Delivery Fee Reslncted Delivery Fee I Rehm Receipt Showmg to ' Whom & Date Delivered ` C/ Rekim Rww Shwmp ro Whom Date 8 i TOTAL Poste e & Fees i Pwtmerk • IUUG i Wilmington, NC 28411 USPS I UNITED STATES POSTAL SERVICE First -Mass Mad Postage & Fees Paid USPS Permit No G-10 • Print your name, address, and ZIP Code in this box • North Cnohna Department of Environment & Natrual Resources 127 Cardmal Dr Extension Wilmmgton, North Carohna 28405 Attn Brenda $ SENDER. I to 00r. pooto dame t andror 2 for additional someas also wish receive the q •Complete Items 3 4a and 4b following services (for an y •Pdnt your name and address on the reverse of tree Conn so that" can retum tna extra fee) card to you •Attach thre form to the from of the mailpiece or on the beck d apace does not 1 ❑ Addressee's Address pemmt • Wdte'Retum Receipt Requested en the mallpiece below the article number 2 ❑ Restricted Delivery -The Return Receipt will show to whom the snide was delivered and the date delivered 0 Consult postmaster for fee 3 Article Addressed to 4a Article Number / z ice 4b Service Type (J %O � ❑ Registered sure d / /? �4� ❑Express Mail ❑Insured ❑ Return Receipt for Merchandise ❑ COD 7 Date /��lvery"!P 5 Received By (Print Name) 8 Addressee's Address (Only if re4uested and fee is paid) g 6 Signature (Addresse9 or Agent) 0 gin PS Form 3811, December 1994 102595-97 8-0179 Domestic Retum Receipt State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office James B Hunt, Jr , Governor Wayne McDevitt, Secretary Division of Water Quality December 2,1998 CERTIFIED MAIL MZ 153 115 216 RETURN RECEIPT REQUESTED Mr J T Mildenberg, President JTM 6013 Wellesley Place Wilnungton, NC 28409 SWOUVWA NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NR RAL RESOURCES Subject REQUEST FOR STORMWATER MANAGEMENT PERMIT APPLICATION JTM Commerical Development Stormwater Project No SW8 981207 Brunswick County Dear Mr Mildenberg On December 1, 1998, the Wilmington Regional Office received a copy of the Notice of Receipt Of Erosion & Secimentation Control Plan for JTM Commerical Development The North Carolina Administrative Code requires any project that must receive either a Sedimentation and Erosion Control Plan permit and/or a CAMA major permit to apply for and receive a Stormwater Management Permit by the Division of Water Quahty Any construction on the subject site, prior to receipt of the required permit, will constitute a violation of 15A NCAC 2H 1000 and may result in appropriate enforcement action by this Office Either a Stormwater Permit Application Package including 2 sets of plans, completed application form, fee, and supporting documentation, or a written response regarding the status of this project and the expected submittal date must be received in this Office no later than January 2, 1999 Failure to respond to this request may result in the initiation of enforcement action, and construction may experience a subsequent delay Please reference the Project Number above on all correspondence. If you have any questions, please call me at (910)-395-3900 Sincerely, Lmda Lewis Environmental Engineer RSS/arl S \WQS\STORMWAT\STORMSUB\981207 Dec cc Delaney Aycock, Brunswick County Inspections Linda Lewis Central Files 127 Cardinal Dr Ext., WOnungtou, North Cu aluu 28405 Telephone 910-395-3900 FAX 910-350-2004 An Equal Opportwuty Affirmative Action E ployer 50% reryded/10% post-conamner paper State of North Carolina gXlo�' Department of Environment / and Natural Resources c7Fi&CD �� Wilmington Regional Offic Division of Land Resource��Land Quality Section James B Hunt, Jr , Governor NORTH CAROLINA DEPARTMENT OF Wayne McDevitt, Secretary ENVIRONMENT AND NATURAL RESOURCES November 25, 1998 JTM Mr J T Mildenberg, President 6013 Wellesley Place Wilmington, NC 28409 Dear Mr Mildenberg We are in receipt of your X Erosion and Sedimentation Control Plan for JTM Commerical Development, Project No 981123BR Revised Erosion and Sedimentation Control Plan for , Project No We regret that we cannot begin processing this submittal until we have received the necessary fees as authorized by the 1990 North Carolina General Assembly in G S 113A-54 2 and as set forth in the fees schedule adopted by the -North Carolina Sedimentation Control Commission in 15A NCAC 4B 0027 Your plan is deemed incomplete and the statutory time period for our review will not begin until the required fee is paid Please remit by check or money order the amount of $27O 00 payable to the North Carolina Department of Environment, Health, and Natural Resources DO NOT SEND CASH Payments should be mailed to NC Department of Environment, Health, and Natural Resources Land Quality Section 127 Cardinal Drive Extension Wilmington, North Carolina 28405 Full payment must be received by this office within 30 days or your submittal will be returned unprocessed A copy of the fee schedule as adopted by the North Carolina Sedimentation Control Commission is attached The section pertaining to the materials that you have submitted has been highlighted See the fee schedule for further explanation If you have any additional questions, please call our office Sincerely, Carol N Miller Environmental Technician CNM/trw cc WiRO-LQS 127 North Cardinal Drive Wilmington N C 28405 3845 • Telephone 910 395 3900 • Fax 910 350 2004 An Equal Opportunity Affirmative Action Employer A State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Division of Land Resources Land Quality Section James B Hunt, Jr , Governor Wayne McDevitt, Secretary 11 1 rr �o NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES November 25, 1998 NOTICE OF RECEIPT OF EROSION & SEDIMENTATION CONTROL PLAN JTM Mr J T Mildenberg, President 6013 Wellesley Place Wilmington, NC 28409 Dear Mr Mildenberg This office has received a soil erosion and sedimentation control plan for the project listed below which was submitted as required by the North Carolina Sedimentation Pollution Control Act (NCGS 113A- 57(4)) Please be advised that this Act requires that all persons disturbing an area of one or more acres of land must obtain approval of a soil erosion control plan prior to the commencement of said land -disturbing activity (NCGS 113A-54(d)(4)) The Act further states that this plan must be filed a minimum of 30 days prior to the activity and the approving authority must approve or disapprove the submitted plan within 30 days of receipt Failure of the approving authority to approve or disapprove the submitted plan within the 30 day period will be deemed approval of the plan if the submitted plan is complete Commencement or continuation of a land -disturbing activity under the jurisdiction of this Act prior to the approval of an erosion and sediment control plan is a violation of the Act We have performed a preliminary review of your submitted plan and have determined that additional information will be necessary before a final review can be completed Enclosed is a checklist of items that must be submitted before we can comolete the review process Failure to provide the additional information may result in disapproval of your plan If you have questions or need additional information, please do not hesitate to contact this office Your cooperation in this matter is appreciated and we look forward to working with you on this project Sincerely, Carol N Miller Environmental Technician CNM/trw cc Mr S Keith Craig, P E , Pyramid Engineering, Inc PROJECT NAME JTM Commerical Development PROJECT NO 981123BR LOCATION NC Hwy 211 - Brunswick County RIVER BASIN Cape Fear SUBMITTED BY Pyramid Engineering, Inc DATE RECEIVED BY L Q S November 23, 1998 127 North Cardinal Drive, Wilmington, N C 28405-3845 • Telephone 910-395-3900 • Fax 910-350-2004 An Equal Opportunity Affirmative Action Employer State of North Carolina Department of Environment and Natural Resources �. Wilmington Regional Office Division ofLand Resources NCDENR Land Quality Section PROJECT NAME JTM Commerical Development NORTH CAROLINA DEPARTMENT OF P ENVIRONMENT AND NArURAL RESOURCES PROJECT NUMBER 981123BR DATE November 23, 1998 EROSION AND SEDIMENTATION CONTROL PLAN CHECKLIST To expedite the approval process, a cursory review of your submitted Erosion Control Plan has been made and has shown the need for additional information as specified below To meet our review schedule, any additional Information should be received by this Regional Office no later than December 18, 1998 Failure to meet this schedule may result in disapproval of your plan LOCATION OF PROJECT DESIGN CALCULATIONS X Including roads, streets, watercourses, _ Pre- & Postconstruction runoff calculations for and other major landmarks or features each outlet from site let each peak discharge location) _ Culverts and storm sewers GENERAL SITE FEATURES X Open channels, existing & planned (ncludetemp linings) X Energy dlssipators, (include stone size and dimensions) Legend, none snow plan scale erosion control measures to X Sediment basins, pits, check dams Property Imes and boundaries of total tract X Existing and proposed contours FINANCIAL RESPONSIBILITY/OWNERSHIP(FR/OI FORM Limit and acreage of disturbed area Planned & existing buildings and elevations X Completed, notarized FR/O Form Planned & existing road locations and elevations X Accurate application fee Geologic features, such as streams, lakes, dams, Certificate of assumed name it owner is a Pane ahip wetlands, seeps, springs, rock outcrops, etc Easements & adjoining property uses _VEGETATIVE STABILIZATION Profiles, streets, utilities, lateral ditchlines, etc Stockpile locations X Methods of soil preparation X Seed type and rates (temporary and permanent) BORROW AND/OR WASTE AREAS X Fertilizer type and rates If the same person conducts the land disturbing activity and any X Mulch type and rates related borrow or waste activity that borrow/waste activity shall constitute part of the land disturbing activity unless the borrow/ EROSION CONTROL MEASURES waste activity is Permitted and/or regulated under the Mining Act of 1971 or is a landfill regulated by the Division of solid waste x Location of measures, temporary & permanent Management If the land disturbing activity and the related borrow/ X Construction details of temporary &permanent measures waste activity are not conducted by the same financially responsible X Maintenance requirements of all measures party they shall be considered separate land disturbing activities _ Contact persons for maintenance of measures SITE DRAINAGE FEATURES NARRATIVE AND CONSTRUCTIONSEQUENCE X Drainage features, existing and planned (including X Nature and purpose of the project off -site areas that drain through the project) X Construction sequence as it relates to erosion Size of sub -watershed (Acres) control, including provisions for installation Culverts & sewers, size and location of critical measures prior to the initiation of Soils information (Type, special characteristics, etc ) the land -disturbing activity, all maintenance Name and classification of receiving watercourse or measures, and removal of measures after areas name of municipal operator (where stammerer is dischargedl they serve have been permanently stabilized OTHER INFORMATION PLEASE NOTE Under Erosion Control Measures Location of measures, temporary & permanent, add (contruction entrance) 127 Cardinal Drive Extension, Wilmington, N C 28405-3845 • Telephone 910-395-3900 • Fax 910-350-2004 An Equal Opportunity Affirmative Action Employer