Loading...
HomeMy WebLinkAboutSW8980434_HISTORICAL FILE_20150202STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO sws `18o`i3y DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS LN HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 2p15 O2-02 YYYYMMDD i r_ NCDENR North Carolina Department of Environment and Pat McCrory Governor February 2, 2015 Charles A Paul, III Bald Head Island Limited, LLC P O Box 3069 Bald Head Island NC 28461 Subject Stormwater Permit No SW8 980434 Renewal Row Boat Row Subdivision High Density Subdivision Project Brunswick County Dear Mr Paul Natural Resources Donald van der Vaart Secretary Effective August 1 2013 the State Stormwater program has been transferred from the Division of Water Quality (DWQ) to the Division of Energy, Mineral and Land Resources (DEMLR) All previous references to DWQ will remain in older stormwater permits issued prior to August 1, 2013 until they are modified Please note that any updated pages or addendums to this permit will now reference DEMLR as the Division responsible for issuance of the permit The Wilmington Regional Office received a complete 8 year Stormwater Management Permit Renewal Application for Row Boat Row Subdivision on December 19, 2014 The Division is hereby notifying you that permit SW8 980434 has been renewed on February 2, 2015 and shall be effective until April 7, 2022 The renewal and reissuance of this stormwater permit does not imply that the site is currently in compliance with the terms and conditions of this state stormwater permit The plans previously approved on December 17 1998, and subsequently last modified on June 24 2004, will remain in full force and effect in accordance with the regulations set forth in Title 15A NCAC 2H 1000 effective September 1, 1995 Please attach this cover letter and permit addendum to your High Density Permit last issued on June 24, 2004 This permit is subject to the conditions and limitations as specified therein Please pay special attention to the conditions listed in this permit regarding the Operation and Maintenance of the BMP(s), recordation of deed restrictions, procedures for changes of ownership, transferring the permit and renewing the permit Failure to establish an adequate system for operation and maintenance of the stormwater management system, to record deed restrictions, to transfer the permit, or to renew the permit, will result in future compliance problems If the property for this project has been/will be sold or legally transferred to another entity OR, the project or permit holder has changed its name and/or marling address, it is your responsibility as the permntee to submit a completed and signed Name/Ownership change form to DEMLR at least 30 calendar days prior to making the changes These forms are available on our website at htto //portal ncdenr ore/web/Ir/state-stormwater forms does if any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing by filing a written petition with the Office of Administrative Hearings (OAH) The written petition must conform to Chapter 150B of the North Carolina General Statutes, and must be filed with the OAH within thirty (30) days of receipt of this permit You should contact the OAH with all questions regarding the filing fee (if a filing fee is required) and/or the details of the filing process at 6714 Marl Service Center, Raleigh, NC 27699 6714, or via telephone at 919 431 3000, or visit their website at www NCOAH com Unless such demands are made this permit shall be final and binding If you have any questions need additional copies of the permit or approved plans, please contact Steve Pusey with the Division of Energy Mineral and Land Resources in the Wilmington Regional Office at (910) 796-7215 Sincerely, Tracy Davis P E , Director —'� Division of Energy, Mineral and Land Resources GDS/sgp G \WQ\Stormwater\Permits & Projects\1998\ 980434 HD\ 2015 02 permit 980434 cc Bruce J Marek, PE Brunswick County Inspections Wilmington Regional Office Division of Energy Mineral and Land Resources Land Quality Section — Wilmington Regional Office 127 Cardinal Drive Extension Wilmington North Carolina 28405 (910) 796 7215 / Fax (910) 350 2004 February 2 2015 Row Boat Row Subdivision SW8 980434 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENERGY, MINERAL AND LAND RESOURCES STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY SUBDIVISION DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Bald Head Island Limited, LLC Row Boat Row Subdivision Bald Head Island Brunswick County FOR THE construction, operation and maintenance of fourteen (14) infiltration trench systems in compliance with the provisions of 15A NCAC 2H 1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Energy, Mineral and Land Resources and considered a part of this permit The permit is hereby renewed subject to the following addendums, clarifications conditions and limitations The original permit conditions contained in the permit issued on December 17, 1998 and as subsequently modified, shall remain in full force and effect, except as amended herein (An additional copy of this original permit can be obtained from the Division of Energy, Mineral and Land Resources Wilmington Regional Office ) 2 This permit shall be effective from the date of issuance until April 7 2022 The permittee shall submit a permit renewal application request at least 180 days prior to the expiration date of this permit The renewal request must include the applicable documentation and the processing fee 4 If the use of permeable pavement is desired, this permit must be modified to add the permeable pavement conditions DEMLR USE ONLY Date Received I Fee Paid Permit Number o State of North Carolina Department of Environment and Natural Resources Division of Energy Mineral and Land Resources (NCDENR DEMLR) STORMWATER MANAGEMENT PERMIT RENEWAL APPLICATION FORM This form may be photocopied for use as an original This form is to be completed by the current permit holder pursuant to Title 15A NCAC 2H 1003 (h) (2) This states that stormwater management permits, issued for projects that require the construction of engineered stormwater control measures (High Density Permits) shall be required to submit an application to renew the permit 180 days prior to expiration of the permit Renewed permits are valid for a period of 8 years per Session Law 2011-398 (SB 781) Section 60 (c) I SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the North Carolina Department of Environment and Natural Resources (NCDENR) Division of Energy Mineral and Land Resources (DEMLR) A complete package includes all of the items listed below The complete application package should be submitted to the appropriate DEMLR Regional Office (The appropriate office maybe found by clicking on the interactive online map at httl2 //aortal ncdenr org/web/guest/regional-offices Copies of the original permit can be obtained from the Regional Office of the Division of Energy, Mineral and Land Resources ) This Renewal is for STORMWATER PERMIT # SW 8 980434 Please check which of the following permit renewal scenarios apply Imhal in the spaces provided that you have provided the required information ® A Renewal Only $505 fee/444 Renewal Form - Sign and complete all sections (send original & I copy) Recorded Documents Required By Permit Deed restrictions covenants condominium/phnned community declaration & easements (if not already submitted to NCDENR DEMLR) Copies are acceptable -Designer s Certification (if required by permit and not already received by NCDENR DEMLR) (See the -n last page of your pernut for a copy of the certification form ) -1 Have a Copy of the Current Operation and Maintenance Agreement (O&M) Please Keep this on File �n with your permit -1 Do Not Have a Copy of the Current O&M Initial This Line to Request a copy (If NCDENR DEMLR does not have a copy on file then you will be notified to submit a nero O & M form ) ❑ B Renewal and Modification -$505 Fee and Pages 1 & 2 of this Renewal Form -SWU 101 Application Form ( http 1/portal ncdenr org/web/toq/ws/su/statesw/fonns does ) -Recorded Documents Required By Permit Deed restrictions covenants condominium/planned community declaration & easements (if not already submitted to NCDENR DEMLR) Copies are acceptable - Under till I on SWU 101 Application Form --Check Box for Modification w/Renewwallg--gip -Designers Certification (if required by permit and not already received by NCDENR' Ut��ulk/ y�zq}ar� last page of your permit for a copy of the certification form) - O&M Agreement ( http //portal ncdenr org/web/wq/ws/su/bmp manual) ygl DEC 19 2014 Form SWU 102 (Renewal Form) Rev Oct 31 2013 Page I of BY- 0 C Renewal and Either 1) Permit Transfer to a New Permittee. or 2) Project Name Change Please submit all items in I A, and Request a NCDENR DEMLR site inspection if transferring permit to new property owner Submit One of the Two Following Forms below (forms available at http //oortal ncdenr org/web/Ir/state stormwater-forms does) 1 HOA Name/Ownership Change Form For planned communities (per Chapter 47C or Chapter 47F of the General Statutes) 2 Name/Ownership Change Form For all other transfers Please make sure all required information is submitted with the Name/Ownership Change form (as stated in each of the available forms) and th it all required signatures and initials are filled in properly Otherwise the name change or transfer can not be processed and the original owner will remain as the permit holder ❑ D Renewal, Modification, and Transfer (or Name Change) Please submit vases 1 and 2 of this Renewal form along with all items listed in I B and C above (check this box and initial items in B & C that you are submitting to NCDENR DEMLR) II APPLICANT'S CERTIFICATION Note The legally responsible party is the current permittee ind/or the legally responsible representative until such time that the permit is officially transferred through a request to DEMLR by the permatee I, (print or type name of permittee or person legally responsible for the permit ) Charles A Paul, III certify that 1 have a copy of the DEMLR Approved Permit and O&M Agreement on site (OR I have obtained a copy from DEMLR and it will be kept on site) that I am responsible for the performance of the maintenance procedures and the site has been and will be maintained according to the O & M Agreement I agree to notify DEMLR of any problems with the system and prior to any changes to the system or changes in ownership I will (or have through this renewal application) notify NCDENR DEMLR and submit the proper forms to modify or transfer the permit All information provided on this permit renewal application is to the best of my knowledge, correct and complete Permittee Title Chief Executive Officer Address P O Box 3069, Bald Head Island, NC 28461 Phone 910 NOTARIZATION 1, L lei A/UQ c fir f-6S a Notary Public for the State of If af% �A2rl/ dIL . County of RR u asW,'c 1<, , do hereby certify that CiN a a )o 5 R &2 f personally appeared before me this day of 14e t""bt;e ex" "a-nr q and acknowledge the due execution of the forgoing stormwater BMP maintenance requirements Witness my hand and official seal, My commission expires Notary Signature _ r ECEIVER DEC 19 2014 BV " �6pTA'41- U 'OUB0 Form SWU-102 (Renewal Form) Rev Oct 31 2013 Page 2 of III GENERAL INFORMATION 1 Stormwater Management Permit Number SW8-980434 2 Permit Holder s name (specify the name of the corporation individual, etc ) Bald Head Island Linited, LLC 3 Print Owner/Signing Official's name and title (person legally responsible for permit) 4 Mailing Address for person listed in item 2 above City Bald Head Island State NC Zip 28461 Phone (910 ) 457-5000 Email cpaul®bhisland com 5 Project Name 6 Location of Project (street address) Fax (910 ) 457-7273 City Bald Head Island County Brunswick Zip 28461 7 Directions to project (from nearest major intersection) Take the Bald Head Island Ferry to Bald Head Island from the Deep Point Marina Ferry Terminal,1301 Road, As Ferry enters the Bald Head Island Manna, Row Boat Row is on the left (North) side of the entrance channel After disembarking from the Ferry, proceed around the manna counterclockwise until you come to Row Boat Row (If walking from the ferry terminal, folloK the brick walkway to the south end of the marina, then take the wood walkway (to the left) between the marina bulkhead and the Admm Building/Harbormaster office Proceed around the barge ramp and then behind (marshward) of MOIO's marmaside restaurant Turn Left and follow northward along Keelson Row to Transom Row Turn Lefton Transom Row, follow to end at Row Boat Row Turn left and proceed south along Row Boat Row towards the marina entrance channel Project area is to both sides of Row Boat Alternate is to pre -arrange with the Bald Head Island Limited, LLC Planning Department for golf cart ride to the site (910-457-7515 general, or Director of Plannmg & Development Tim Henry 910-457-7268) Form SWU 102 (Renewal Form) Rev Oct 31 2013 Page 3 of IV PERMIT INFORMATION 1 Specify the type of stormwater treatment ❑Constructed Wetland ❑Bioretenhon ❑ Wet Detention Pond ❑Dry Detention Basin ®Infiltration Basin ❑Infiltration Trench ❑Sand Filter ®Other Infil Pipe 2 If any changes were made to the original DEMLR approved project list them in the space below (attach additional pages if needed and provide As Built drawings with this application) If major changes have been made to your project please request a plan revision or modjfjc-ition of the permit and submit As Built drawings along with a final or updated stormwater system engineer certification (if not already provided to NCDENR) DEMLR Engineer and Designer Certification Forms are available from each NCDENR DEMLR Regional Office Form SWU 102 (Renewal Form) Rev Oct 31, 2013 Page 4 of State Stormwater Management Systems Permit No SW8 980434MOD Stormwater Protect Number SW8 980434 Mod Bald Head Island -Row Boat Row Subdivision Brunswick County Designer's Certification V �J�� Page 1 of 2 V� I, AA12Ci� S J // piq< , as a duly registered/,W,-',RV/'oyA-L CtiAn in the State of North Carolina, having been authorized to observe (penodic weekly/full time) the construction of the project, W / (Project) for AA-c A %�� 1S61 Iim l &4Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications Required Items to be checked for this certification to be considered complete are on page 2 of this form Noted deviations from approved plans and specifications Signature Jwowf� Registration Number /5(Q Date _ 'a _ /91- 44 a; 0�.0 essioti`�y = 1 ECEIVE DEC 19 2014 8Y Page 8 of 9 State Stormwater Management Systems Permit No SW8 980434MOD Page 2 of 2 Designer Certification Requirements 1Sf /V/Ake /LacJ ortT 1 The drainage area to the system contains approximately the permitted acreage �2 The drainage area to the system contains no more than the permitted amount of built -upon area 3 All the built -upon area associated with the protect is graded such that the /J runoff drains to the system A4 The outlet/bypass structure elevations are per the approved plan a-5 The outlet structure is located per the approved plans d%6 Trash rack is provided on the outlet/bypass structure ��7 All slopes are grassed with permanent vegetation ril-8 Vegetated slopes are no steeper than 3 1 9 The inlets are located per the approved plans and do not cause short- circuiting of the system )i %10 The permitted amounts of surface area and/or volume have been provided N1 Required drawdown devices are correctly sized per the approved plans U12 All required design depths are provided "13 All required parts of the system are provided, such as a vegetated shelf, and a forebay 14 The dimensions of the system, per the approved plans, are provided cc NCDENR-DWQ Delaney Aycock, Brunswick County Building Inspections Page 9 of 9 State Stormwater Management Systems Permit No SW8 980434MOD Stormwater Project Number SW8 980434 Mod Page 1 of 2 Bald Head Island -Row Boat Row Subdivision Brunswick County Designer's Certification I, A/2UG� c) , as a duly registeredA 01ce5s/0dAK ZN4* the State of North Carolina, having been authorized to observe (periodical weekly/full time) the construction of the project, kowl)kziz/ f 2al (Project) for/{�� f Sj/��/A�iT697 ��`(�Protect Owner) hereby state that, to the best of my a ilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications Required Items to be checked for this certification to be considered complete are on page 2 of this form Noted deviations from approved plans and specifications Signature Registration Number Date .`%%`tN DAROCi IML SEAL _ 15684 K y hn Page 8 of 9 State Stormwater Management Systems Permit No SW8 980434MOD Page 2 of 2 Designer Certification Requirements ILV6 I&A", lff_4�2 1 The drainage area to the system contains approximately the permitted acreage 3A2 The drainage area to the system contains no more than the permitted amount of built -upon area �3 All the built -upon area associated with the protect is graded such that the runoff drains to the system '�A4 The outlet/bypass structure elevations are per the approved plan X�L5 The outlet structure is located per the approved plans 6 Trash rack is provided on the outlet/bypass structure 7 All slopes are grassed with permanent vegetation 8 Vegetated slopes are no steeper than 3 1 9 The inlets are located per the approved plans and do not cause short- circuiting of the system �0 The permitted amounts of surface area and/or volume have been provided 11 Required drawdown devices are correctly sized per the approved plans 012 All required design depths are provided i/4--13 All required parts of the system are provided, such as a vegetated shelf, and a forebay 4A14 The dimensions of the system, per the approved plans, are provided cc NCDENR-DWQ Delaney Aycock, Brunswick County Building Inspections Page 9 of 9 State Stormwater Management Systems Permit No SW8 980434MOD Stormwater Project Number SW8 980434 Mod Bald Head Island -Row Boat Row Subdivision Brunswick County Designer's Certification Page 1 of 2 I, AllgeX , as a duly registered &F§-5S/o kt 14i� in the State of North Carolina, having been authorized to observe (periodically/ weekly/full time) the construction of the project, k. 10A #--3 (Protect) for 3t_11 4R)1w,1-LG(Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the protect construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications Required Items to be checked for this certification to be considered complete are on page 2 of this form Noted deviations from approved plans and specifications Signature Registration Number�����/ Date A 1P „. N CARP cep QOF ES s1 ot,�`'Ly';, SEWAL 15684 9 DEC 19 2014 F� Page 8 of 9 State Stormwater Management Systems Permit No SW8 980434MOD Page 2 of 2 Designer Certification Requirements %j/LIIL� T 114)Z 6K a1 The drainage area to the system contains approximateTy the permitted U2 acreage The drainage area to the system contains no more than the permitted amount of budt-upon area �3 All the built -upon area associated with the project is graded such that the runoff drains to the system a4 The outlet/bypass structure elevations are per the approved plan 4L5 The outlet structure is located per the approved plans 6 Trash rack is provided on the outlet/bypass structure 7 All slopes are grassed with permanent vegetation 8 Vegetated slopes are no steeper than 3 1 9 The inlets are located per the approved plans and do not cause short- circuiting of the system Ax10 The permitted amounts of surface area and/or volume have been provided it/ 11 Required drawdown devices are correctly sized per the approved plans 12 All required design depths are provided AA-13 All required parts of the system are provided, such as a vegetated shelf, and a forebay 014 The dimensions of the system, per the approved plans, are provided cc NCDENR-DWQ Delaney Aycock Brunswick County Building Inspections Page 9 of 9 State Stormwater Management Systems Permit No SW8 980434MOD Stormwater Protect Number SW8 980434 Mod Bald Head Island -Row Boat Row Subdivision Brunswick County Designer's Certification Page 1 of 2 I, A , as a duly registered_AOF-,�-5sLo&,L�L C,G Gtin the State of North Carolina, having been authorized to observe (periodically/ weekly/full time) the construction of the protect, u k 19 aim (Protect) for M�Aw k L /,Zmloy, LLr_(Protect Owner) hereby state that, to the best of my abilities, due care and ddige ce was used in the observation of the protect construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications Required Items to be checked for this certification to be considered complete are on page 2 of this form Noted deviations from approved plans and specifications Signature Registration Number Date H CAgp''•.,. 0 fess,o 4�•y'•;, QQSEAL SEAL Jz = 15OPh Page 8 of 9 State Stormwater Management Systems Permit No SW8 980434MOD Page 2 of 2 Designer Certification Requirement2vGb�� � / "'6 qc /or v l9r 16 ,M 1-76: l� 1_2�1 The drainage area to the system contains approximately the permitted Jt2 acreage The drainage area to the system contains no more than the permitted amount of built -upon area /yjM3 All the built -upon area associated with the protect is graded such that the runoff drains to the system �t4 The outlet/bypass structure elevations are per the approved plan �5 The outlet structure is located per the approved plans 6 Trash rack is provided on the outlet/bypass structure 7 All slopes are grassed with permanent vegetation 8 Vegetated slopes are no steeper than 3 1 A114-9 The inlets are located per the approved plans and do not cause short- circuiting of the system 10 The permitted amounts of surface area and/or volume have been provided i1% _11 Required drawdown devices are correctly sized per the approved plans jMl2 All required design depths are provided AZ4413 All required parts of the system are provided, such as a vegetated shelf, and a forebay 14 The dimensions of the system, per the approved plans, are provided cc NCDENR-DWQ Delaney Aycock, Brunswick County Building Inspections r=CU= 0VS s DEC 19 2014 Page 9 of 9 Casmer, Jo From Casmer Jo Sent Tuesday, December 30 2014 3 13 PM To cpaul@bhisland com' Subject Row Boat Row Stormwater Permit SW8 980434 The Wilmington Regional Office of the Division of Energy Mineral and Land Resources (Stormwater Section) received the Stormwater Permit Renewal Application and $505 00 fee on December 19 2014 Your project will be assigned to a staff member and you will be notified if additional information is needed Jo Casmer Administrative Assistant for DEMLR/Stormwater Section NC Department of Environment & Natural Resources 127 Cardinal Drive Extension \V.iImmgton NC 28405 Phone (910) 796 7336 Fax (910) 350-2004 Email correspondence to and from this address may be sub/ed to the North Carolina Public Records Law and may be disclosed to third parties �< ll1C.i rr t Zla;1 I r 1 1) 1 L CI ' i ry j j[. I ;Ir Ir rip 1 1( % 'JII 1V IL U II ( Oil \ II;'I -i GI' 1 1 1 JU I 11 1 r n 14 I 1 I1J r rj( Oro )I it i fll 1 c Jr F- � cn 1;III I 9U(i 1 3' j' yU Cb-F ")PPI?I 'I ; ( QL'I EIUUJ Q�C'A6t IG i Project Name 9(,k4�-I-skrvucA 1 neceiveuvaM .y Project Location +ig t SL�6 Ck c- Accepted Dater_ Z� i*-f Rule(s) 2008 Coastal 11 1995 Coastal nPhase II (WiRO) Umversal Type of Permit New or Mod or PR Existing Permit # (Mod or PR) 91R O q or LD-1 Type —Comr (%OK?) Stream Class Map Paperwork Emailed Engineer on Supplement(s) (1 original per BMP) BMP Type(s) O&M with correct/original signatures (1 original per BMP except LS/VFS and swales) Application with correct/original signatures 1:1Deed Corp or LLC Sig Auth per SoS or letter Email Address $505 (within 6mo) Email Address L=J1988 Coastal PE Cert on File? a to SW8 Design Engineer Owner Soils Report with SHWT Note to Reviewer Calculations (signed/seajed) CL4 No obvious errors v� ®Density includes common areas, etc ®Deed Restrictions, if subdivided ®Signed & Notarized s un/i n1 nr Dec Covenants &Rest�ycj) t 2 Sets Details (roads, cul-de-sacs, curbs, sidewalks, BMPs, Buildings, etc) Grading Wetlands Delineated or No Wetlands Vicinity Map Layout (proposed BUA dimensions) DA Maps Project Boundaries ®LegendEI Infiltration Wet Pond Offsite Soils Report Soils Report PE Cert for Master Lot # SHWT SHWT Deed Rest for Master Lot # Matches Master Bottom PP BUA Permitted (Master) sf BUA Proposed (offsite) sf Additional Information ®rnnnced Permitted wroposea- BUA (sf) DA (sf) PP (el) SHWT (el) Depth (ft) SA (sf) fFi r NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor March 22, 2011 Mr Kent Mitchell, President Bald Head Island Limited P O Box 3069 Bald Head Island, NC 28461 Division of Water Quality Coleen H Sullins Director Subject Permit Extension, Session Laws 2009-406 and 2010-177 Stormwater Permit #SW8 980434 High Density — Row Boat Row Subdivision Brunswick County Dear Mr Mitchell Dee Freeman Secretary On August 5 2009, the Governor signed Session Law 2009-406 This law impacts any development approval issued by the Division of Water Quality under Article 21 of Chapter 143 of the General Statutes, which is current and valid at any point between January 1 2008, and December 31, 2010 The law extends the effective period of any stormwater permit that is set to expire during this time frame to three (3) years from its current expiration date On August 2 2010 the Governor signed Session Law 2010- 177 which grants an extra year for a total of four (4) years extension Accordingly, Stormwater Permit # SW8 980434 which has already expired on April 7, 2010, is now in effect until Apnl 7, 2014 Please resubmit the renewal application and fee at least 180 days prior to Apnl 7, 2014, which would be October 7, 2013 A copy of the Renewal Application can be obtained from the following website http Hportal ncdenr org/web/wq/ws/su/statesw/forms_docs If you have any questions, please contact the Division of Water Quality in the Wilmington Regional Office at 910-796-7215 Sincerely, Georgette Scott Stormwater Supervisor Division of Water Quality S \WQS\STORMWATER\RENEWAL\SL2009-406 2010-177\980434 marl cc Wilmington Regional Office Wilmington Regional Office 127 Cardinal Drive Extension Wilmington North Carolina 28405 One Phone 910 796 72151 FAX 910 350 2004 \ Customer Serves 1 87766748 1 v23 L, 1 NorthCarolina a Internet x ncwaterquality org Naturally An Equal Opportunity l Affirmative Action Employer