Loading...
HomeMy WebLinkAboutSW8950821_HISTORICAL FILE_19951017STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 Oi5082-1 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ® HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE q o1510 I'1 YYYYMMDD 'State of North Carolina IT nepartment of Environment, F!XA Health and Natural Resources 4 .�, Division of Environmental Management ' James B. Hunt, Jr., Governor p E H N FR Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director October 17. 1995 Mr. Joel Tomaselli Lumina Station Partners, L.L.C. 2840 South College Road Wilmington, North Carolina 28412 Subject: Permit No. SW8 950821 Lumina Station High Density Stormwater Project New Hanover County Dear Mr. Tomaselli: The Wilmington Regional Office received the Stormwater Application for Lumina Station on August 17, 1995, with final information on October 2, 1995. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW8 950821 dated October 17, 1995 to Lumina Station Partners, L.L.C.. This permit shall be effective from the date of issuance until October 17, 2005 and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Linda Lewis or me at (910) 395-3900. Sincerer Dave Adkins Regional Water Quality Supervisor DA/arl: S:\WQS\STORMWAT\PERMIT\950821.00T cc: Phil Tripp, P.E. Alan Golden, New Hanover County Inspections Linda Lewis Beth Easley ;Wilmington Regional Office Central Files P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer State Stormwater Management Systems Permit No. SW8 950821 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Lumina Station Partners, L.L. C. Lumina Station New Hanover County Mi��tr:i�. construction, operation and maintenance of stormwater management systems in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Environmental Management and considered a part of this permit. This permit shall be effective from the date of issuance until October 17, 2005 and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 3 of this permit, the Project Data Sheet. 3. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 2 d State Stormwater Management Systems Permit No. SW8 950821 Project Name: Permit Number: Location: Applicant: Mailing Address: DIVISION OF ENVIRONMENTAL MANAGEMENT Application Date: Water Body Receiving Stormwater Runoff: Classification of Water Body: If Class SA, chloride sampling results: Pond Depth: Permanent Pool Elevation: Total Impervious Surfaces Allowed: Offsite Area entering Pond: Green Area entering Pond: Required Surface Area: Provided Surface Area: Required Storage Volume: Provided Storage Volume: Temporary Storage Elevation: Controlling Orifice: PROJECT DATA Lumina Station 950821 New Hanover County Mr. Joel Tomaselli Lumina Station Partners, L.L.C. 2840 South College Road Wilmington, North Carolina 28412 August 17, 1995 UT Mons Creek 05 N/A 7.5 feet 10.5 MSL 122,500 square feet N/A square feet 73,036 square feet 3,922 square feet 3,940 square feet 11,036 cubic feet 13,039 cubic feet 13 MSL 1.5" pipe 3 State Stormwater Management Systems Permit No. SW8 950821 4. The developer shall not be allowed to fill in, alter, or pipe any vegetative practices (such as swales) shown on the approved plans as part of the stormwater management system without submitting a revision to the permit and receiving approval from the Division. 5. The following items will require a modification to the permit: a. Any revision to the approved plans, regardless of size. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area. e. Further subdivision of the project area. In addition, the Director may determine that other revisions to the project should require a modification to the permit. 6. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. II. SCHEDULE OF COMPLIANCE 1. The permittee will comply with the following schedule for construction and maintenance of the stormwater management system: a. The stormwater management system shall be constructed in it's entirety, vegetated and operational for it's intended use prior to the construction of any built -upon surfaces except roads. b. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 2. The facilities must be properly maintained and operated at all times. The approved Operation and Maintenance Plan must be followed in it's entirety and maintenance must occur at the scheduled intervals. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of side slopes. d. Immediate repair of eroded areas. e. Maintenance of side slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DEM. The records will indicate the date, activity, name of person performing the work and what actions were taken. C! State Stormwater Management Systems Permit No. SW8 950821 This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 6. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Mail the Certification to the Wilmington Regional Office, 127 Cardinal Drive Extension, Wilmington, North Carolina, 28405, attention Water Quality Section. 7. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. M. GENERAL CONDITIONS This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Pennittee, a formal permit request must be submitted to the Division of Environmental Management accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Environmental Management, in accordance with North Carolina General Statute 143-215.6(a) to 143-215.6(c). 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. Permit issued this the 17th day of October, 1995. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION A. -Preston Howard, Jr., P.E., Director Division of Environmental Management By Authority of the Environmental Management Commission Permit Number SW8 950821 State Stormwater Management Systems Permit No. SW8 950821 Lumina Station Stormwater Project No. 950821 New Hanover County Engineer's Certification I, North Carolina, project, , as a duly registered Professional Engineer in the State of having been authorized to observe (periodically/weekly/full time) the construction of the for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Signature Registration Number Date Gi PGT 9560 DIVISION OF ENVIRONMENTAL MANAGEMENT DENSITY ENGINEERED x PROJECT DATA Project Name Lumina Station Location (County, Township/Municipality, Address, State Road) 1900 Eastwood Road Owner's Name Lumina Station Partners, L.L.C. MailingAddress 2840 South College Road Wilmineton. North Carolina 28412 Phone Number 313-0660 Submittal Date 8-7-95 Brief Description (include mar) and appropriate drawings)_Commercial Park __— Name of Water Body Receiving Stormwater Runoff unamed tribuary to Motts Creek Classification of Water Body SB If SA waters, engineered system, and distance is <0.5 miles, attach report of chloride sampling results mg/I State/Federal Permits/Approvals Required (Check appropriateblanks) CAMA Major Sedimentation/Erosion Control X 404 Permit DEM/DHS Sewage Disposal X Other (Specify) CALCULATION OF BUILT UPON AREA Built upon area means that portion of a development that is covered by impervious or partially pervious cover including buildings, pavement, recreation facilities, gravel, etc., but not including wood decking. If the project includes areas draining to different water classifications, please note them separately below. Classification Built upon area Total Project Area % Built upon Area Allowable B/U Area Subwatershed Subwatershed SB 122,500 SF 19,5SF fit J% 30.0% Is the Project B/U Area 5 the Allowable B/U Area? no (If no, an engineered system is required.) % Built upon area = (built upon area / total project area) * 100 Built upon area limits for projects to meet density: SA waters --- 25%, Other ---30% STORMWATER COLLECTION SYSTEM Describe how the runoff will be treated id Office use only ATE AUG 1 71995 U pr,oJ' SW2r'7S0821 BUFFER AREA Is the built upon area at least 30 feet from mean high water of all surface waters? yes If no, please provide a description (Note: Only boat ramps, public roads, public bridges, and walkways to water related facilities are allowed within 30 feet of the mean high water line if the project is intended to meet stormwater control requirements through density limits.) DEED RESTRICTIONS AND PROTECTIVE COVENANTS By my signature below, I certify that the recorded deed restrictions and protective covenants for this project shall limit the allowable built -upon area per lot to 1 77 ° 500 square feet inclusive of right-of-way, structures, pavement, walkways or patios of brick, stone, or slate, not including wood decking, state that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, and that benefits may be enforced by the State of North Carolina, therefore, the covenant cannot be changed or deleted without consent of the State. CERTIFICATION I, �/�L If` f certify that the information included on this submittal form is correct, that the project will be constructed in conformance with this information, and that to the best of my knowledge, the proposed project complies with the requirements of 15 NCAC 2H.1003 (b). I authorize the below named person or firm to submit stormwater plans on my behalf, and agree to abide by the deed res cti n statement above. Owner's Signature Date Provide authorized person or firm name and address below: Phillip C. Tripp, P.E. 211 North Fifth Avenue Wilmington, North Carolina 28401 Evonne M. Smith a Notary Public for the State of North Carolina County of New Hanover , do hereby certify that Joel Tomaselli personally appeared before me this 7th. day of August 11995 and acknowledges the due execution of the foregoing instrument. Witness my hand and official seal,'""°°F� S My commission expires �p?ARV i puBOC, 2 : ,� �.ti•••• Ate, DIVISION OF ENVIRONMENTAL MANAGEMENT SIGN-OFFS•",,4*ppER•COJ�•' Regional Office 11/14/96 Date c �Ind4 ' ual Evaluating For ans Date ater Quality Supervisor cc: Applicant/WiRO/Bradley Bennett/Central Files PHILLIP G. TRIPP, P.E. 211 North Fifth Avenue • Wilmington, North Carolina 28401 910/763.8124 • Fax 910/762-5772 NCDEHNR Division of Environmental Management Water Quality Section 127 Cardinal Drive Wilmington, NC 28405-3845 Attn: Ms. Linda Lewis Re: Lumina Station Wilmington, NC Revised Stormwater Management Plan PGT No. 9560 Dear Linda: OCT 0 2 1995 ........................... September 29, 1995 Enclosed please find two sets of revised plans. As per your August 22, 1995 correspondence we offer the following with respect to your comments: 1) We revised the spot elevations. 2) We revised the grading at the entrance to include the additional impervious at the entry. Previous calculations had included this area. 3) The bottom invert for SDMH-2 is 12.45 4) We generally do not include building dimensions on our plan but we have enclosed separate sheets with that information. 5) Southerland Avenue is a public road. We had intended the paving only as an improvement to a public street and therefore had not included it in our calculations. Please review for approval and contact me with any questions or comments. Thank you. S' c el , Phi G. Tripp E. STEMMER ECE IV w IJ OCT 0 2 1995 rRoJ D S 95O 6 Ft---- 133' I I I I I � I I L I co 4' I o BUILDING 1 r— I I � I to qqo s F r I I I F I I 1— I I , ---------------- RR v E D OCT 0 2 1"S '# g g PRol 5o821_. �I BUILDING 2 G3Za I' -------`--- ' --------�JKL6- NOTE: CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS TO VERIFY DIMENSIONS FOR CONSTRUCTION. [in to 1 BUILDING 3 80 1 100, 48vv I I `MmIAlATFE OCT '0 2 1995 rxoJ W SW89so821 _11 BUILDING 4 I 5872.5 I � I l l 1 I 8'-s" I TT -------------� NOTE: CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS TO VERIFY DIMENSIONS FOR CONSTRUCTION. State of North Carolina Department of Environment, Health, and Natural Resources Wilmington Regional Office James B. Hunt, Jr. DIVISION OF ENVIRONMENTAL MANAGEMENT Jonathan B. Howes Governor WATER QUALITY SECTION Secretary September 13, 1995 Mr. Phil Tripp, P.E. 211 North Fifth Avenue Wilmington, North Carolina 28401 Subject: ADDITIONAL INFORMATION Stormwater Project No. SW8 950821 Lumina Station New Hanover County Dear Mr. Tripp: The Wilmington Regional Office received a Stormwater Submittal for the Lumina Station on August 17, 1995. A preliminary review of that information has determined that the submittal for the subject project is not complete. The following information is needed to continue the stormwater review: The elevations of the road on the northwest side of the project appear to create a hole that runoff will not drain off of. Contour 21 dips down to edge of pavement elevations of 20.25 and 19.9. Please clarify. 2. A small amount of impervious area at the entrarice-is.,not picked up by the pond. A trench drain placed just inside the R/W line could pick up the d�rairtage and direct it to either DI-3 or DI-6. I really don't want to set a precedence of allowing impervious surface runoff to escape untreated. In hardship cases where no other alternatives are available, I will consider it. CI-4 invert (12.55) is lower than the upstream SDMH-2 invert (13.50). Perhaps the manhole invert should be 12.5? 4. Please add the dimensions of the buildings. 5. Was Southerlands Avenue accounted for in the impervious area? If the paving of the alley is part of this project, then the drainage must be accounted for. If the paving is only maintenance of an existing DOT right-of-way, then it will not be considered a part of the project, and the drainage will not be required to be picked up in the pond. 127 Cardinal Drive Extension, Wilmington, N.C. 28405-3845 • Telephone 910-395-3900 • Fax 910-350-2004 An Equal Opportunity Affirmative Action Employer Mr. Tripp September 13, 1995 Stormwater Project No. SW8 950921 Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to October 13, 1995, or the submittal will be returned as incomplete. If you have any questions concerning this matter please feel free to call me at (910) 395-3900. Sincerely, Ms. Linda Lewis Environmental Engineer DA/arl: S:\WQS\STORMWAT\ADDINFO\950821.SEP cc: cL-inda_L-ewis Central Files 2 PHILup G. TRipp, P.E. 211 North Fifth Avenue • Wilmington, North Carolina 28401 910/763.8124 • Fax 910/762-5772 NCDEHNR Division of Environmental Management water Quality Section 127 Cardinal Drive Wilmington, NC 28405-3845 Attn: Ms. Linda Lewis Re: Lumina Station Wilmington, NC Stormwater Management Plan PGT No. 9560 Dear Linda: Enclosed please find two sets of maintenance form and two sets review and approval. D AUG 17 1995 August 15, 1995 plans, one application, one pond of sealed calculations for your The project will be served by public water and sewer. Please review for approval and contact me with any questions or comments. Thank you. P ce1 i G. Trip E. cc: Lumina Station, L.L.C. 17, AUG 1 71995 DE FROI # Sw 6 50 I?Z I PGT 9560 POND MAINTENANCE REQUHMIENTS Project Name: Lumina Station . Project No. Responsible Party: Lumina Station Partners, L.L.C. Phone No 313-0660 Address:2840 South College Road Wilmington, NC 28412 I. Monthly, or after every runoff producing rainfall event, whichever comes first: A. Inspect the trash rack; remove accumulated debris, repair/replace if it is not functioning. B. Inspect and clear the orifice of any obstructions. If a pump is used.as the drawdown mechanism, pump operation will be checked. A log of test runs of the pump will be kept on site and made available to DEM personnel upon request. C. Inspect the pond side slopes and grassed inlet swales; remove trash, and repair eroded areas before the next rainfall event. D. If the pond is operated with a vegetated filter, the filter will be checked for sediment accumulation, trash accumulation, erosion and proper operation of the flow spreader mechanism. Repairs/cleaning will be done as necessary. II. Quarterly: A. Inspect the collection system (ie. catch basins, piping, grassed swales) for proper functioning. Accumulated trash will be cleared from basin grates, basin bottoms, and piping will be checked for obstructions and cleared as required. B. Pond inlet pipes will be checked for undercutting, riprap or other energy dissipation structures will be replaced, and broken pipes will be repaired. M. Semi-annually: A. Accumulated sediment from the bottom, of the outlet structure will be removed. B. The pond depth will be checked at various points. If depth is reduced to 75 % of original design depth or 3 feet whichever is greater, sediment will be removed to at least the original design depth. C. Grassed swales, including the vegetated filter if applicable, will be reseeded twice a year as necessary. D AUG 1 7 1995 DEM FROJ # SLuE y50 SZ/ VI I NOV F PAGE 2 IV. General: A. Mowing of the side slopes will be accomplished according to the season. Maximum grass height will be 6". B. Cattails are encouraged along the pond perimeter, however they will be removed when they cover more than 1/2 the surface area of the pond. C. The orifice/pump is designed to draw down the pond in 2-5 days. If drawdown is not accomplished in that time, the system will be checked for clogging. The source of the clogging will be found and eliminated. D. All components of the detention pond system will be kept in good working order. Repair or replacement components will meet the original design specifications as per the approved stormwater plan. V. Special Requirements: hereby acknowledge that I am the financially responsible party for maintenance of this detention pond. I will perform the maintenance as outlined above, as part of a ertification of Compliance with Stormwater Regulations received for this project. Signature:_ Date: Evonne M. Smith North Carolina I, , a Notary Public for the State of , County of New Hanover I do hereby certify that Joel Tomaselli personally appeared before me this 7th. day of August , 19 95 , and acknowledge the due execution of the foregoing instrument. Witness my hand and official seal, S My commission expires 11/14/96 NOTq y': p %GgLIG'�_ J 4� DA/arl: S:\WQS\STORMWAT\FORMS\O&M-POND.FOR°y9Np~�'�• �t�',' V GCie jCC (� Design Sheer —Iy,��J PHuziP G. TRIPP, P.E. �rcemwgrac l aCtUcario S 1 Cf Z 211 North Fifth Avenue Wilmington, NC 28401 For / check Job INC. vm 1-1A ' rC'4 7 TCrAI 1 e*YT �111�A • ��� ,�11/b�,_'/''''' - y. `ftJ� Hct4s I9's"E)� VrZ• 717 1T8T/ d a IIrmPffAim. A(Kn y�0R'Mi TER AUG 1 71995 b FROJ -SW— 9 950 97- 0 ' ImfFKvlous = �O..I�, SIFi WgIkS 'f� Pg2icl,�l FT ACCECg\ l�'lA� Imlf,tylols-. IZZ/50/ r 195183(a LoZ(o5'l0 Z91c7OZo F-r z I�, 185 PT7 78,495 FT r IZZ15oo 1EC, 71b' G l�NN C' fiCMII.IF.,T {%ate F� 10 :5F,IOA � , OZCC6 �7Eliwwa SA = OZM5 = Z7 Fr z K"OfIc CIO Imf4LYlw� _ r`tEa _ 1/1z x IZZ150o t t�z x 73103(� • 0.25 I I, Tao cr 3 EEO �J�RFAc� Y"7±tEA C2 11 46 zI� .3cl FT S p VoLVv4 �JETw44� (105) (13.0) = C3`ido+�#tllz5 = 13I OY9 % J 131 a35 > 111-730 CA DCTe Jeb Design Sheer 8-ie 95 PHua,IP G. Twp, P.E. 6-752mwAT(4 �tFIC Hato is PST Z c; Z Zll North Fifth Avenue VPdtr=gton, NC 28401 For , Check Job No. LUM lySq "-4 9 ydj �lo�,., PC E«,4. lo•� F1� P� Eckv, 13. o Ionm Zkf- 3-0 'FP OF 5A-I V- I ¢. C) f `J tZE Ov vYr Pe Z pay OgtP >O.,.4 = 17ZI ,QCO tkc, A Q 13t 035 / 1��800 cD z�h - o.fa z�3z.zXl.zS) - ,ol•�-oFr z : 7CJL ci = Co,4ox4) - 0.13�1 6AI t Ilz'' bUrlt-r- 6mwullf � �k 4 - I� •5 L'Fs Fv,c �= 13 CH)1.5 U5„t` 4., 4 6ASA 19•S 1�1.5 Pca,� c,cc _ L - IL TleAk EcFv. ' 13.0 + p.Fi�) = 13.51 01--,40 Fc«o,-K, �p State of North Carolina F I L E D s; 9 u 9 Department of the Secretary of State 9-00 ArA LBUM LIABILITY COMPANY APR 0 3 1995 ARTICLES OF ORGANIZATION EFFECTW Pursuant to 157C-2-20 of the General Statutes of North Carolina, the undersigned does here j p �S7f . E Articles of Organization for the purpose of forming a limited liability company. NORTH CAROoNA 1. The flame of the limited liability company is: Lumina Station, LLC 2. The latest date on which the limited liability company is to dissolve is: December 31, 2045 3. The name and address of each organizer executing these articles of organization is as follows (at least two persons must execute this document, attach additional pages if necessary): Racine LEC. James E. Wallace, Jr. Joel L. Tomeselli 102 North 5th Street 1422 Commonwealth Drive 306 Robert E. Lee Dr Wilmington, NC 28401 Wilmington, NC 28403 Wilmington, NC 2841E 4. The street address and county of the initial registered office of the limited liability company is Number and Street 306 Robert E. Lee Drive City, State, Zip Code Wilminaton. NC 28412 County New Hanover r S. The mailing address If different from the street address of the initial registered office is: 6. The named of the initial registered agent is: Joel L. Tamaselli 7. Check one of the following: X (i) Member -managed L L.C: all of the members by virtue of their status as members shall be managers of this limited liability company. (ii) Manager -managed LL.C: except as provided by N.C.G.S. §57C-3-20(a), the members of this limited liability company shall not be managers by virtue of their status as members. 8. Any other provisions which the limited liability company elects to include are attached. 9. These articles will be effective upon Sling, unless a date and/or time is specified: This the0.%--f day of _!March + 1995 rc R ine --, gna T Signature Lionel L. Yow - Member James F. Wallaca- Jr - Type or Print Name and Title Type or Print Name anRrTRfeP1P NOTPS:'SEE ATTACHED SIGNATURE PAGE 1. Filing fee Is $100. Tids document and one end or conformed copy of these attlda mug be filed with the Secretary of State. CORPORATIONS DIVISION 300 N. SA LISBURY STREET RALEIGH, NC 27603-5909 C