Mr Robert S King, Owner
Bob King Pontiac-GMC, Inc
5115 New Centre Drive
Wilmington, North Carolina 28403
Dear Mr King
A4�
EDFEE HNR
November 14, 1996
Subject Permit No SW8 920913 Modification
Bob King Mercedes Showroom and Service Center
High Density Commercial Stormwater Project
New Hanover County
The Wilmington Regional Office received a modification to the Stormwater Management Pernut Apphcation for Bob King
Mercedes Showroom and Service Center on October 25, 1996 Staff review of the plans and specifications has determined that
the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H 1000 We are
forwarding Permit No SW8 920913 Modification dated November 14, 1996, for the construction of Bob King Mercedes
Showroom and Service Center This permit supercedes the one issued to you on October 28, 1992
This permit shall be effective from the date of issuance until November 14, 2006, and shall be subject to the conditions and
limitations as specified therein Please pay special attention to the Operation and Maintenance requirements in this permit
Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in
future compliance problems
If any parts, requirements, or limitations twntamed in this permit are unacceptable, you have the right to request an ajudicatory
hearing upon written request within thirty (30) days following receipt of this permit This request must be in the form of a
written petition, conforming to Chapter 150B of the North Carohm General Statutes, and filed with the Office of Admimstranve
Hearings, P O Drawer 27447, Raleigh, NC 27611-7447 Unless such demands are made this permit shall be final and binding
If you have any questions, or need additional information concerning this matter, please contact Linda Lewis, or me at (910)
395-3900
Sincerely, p
tC/�ixisk����''l
Ken Eagleson V
Regional Water Quality Supervisor
KE/arl S \WQS\STORMWAT\PERMIT\920913 NOV
cc John Klein, P E
Tony Roberts, New Hanover County Inspections
Beth Easley, New Hanover County Engineering
Linda Lewis
%;Wdimng[on Regional Office
David Mayes, P E
Central Files
P 0 Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919
An Equal Opportunity Affirmative Action Employer
State Stormwater Management Systems
Permit No. SWR 990919 ModificAtmn
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES
DIVISION OF WATER QUALITY
HIGH DENSITY DEVELOPMENT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended,
and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Bob King Pontiac-GMC, Inc
Bob King Mercedes Showroom and Service Center
New Hanover County
FOR THE
construction, operation and maintenance of a Detention Pond in comphance with the provisions of 15A NCAC
2H 1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and
specifications and other supporting data as attached and on file with and approved by the Division of Water
Quality and considered a part of this permit
This permit shall be effective from the date of issuance until November 14, 2006 and shall be subject to the
following specified conditions and limitations
I. DESIGN STANDARDS
This permit is effective only with respect to the nature and volume of stormwater described in the application and other
supporting data
2 This stormwater system has been approved for the management of stormwater runoff as described on page 3 of thus
permit, the Project Data Sheet The stormwater control has been designed to handle the runoff from 54,980 square feet
of impervious area
3 Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the
permit
P7
State Stormwater Management Systems
Permit No SWR 92Q913 Modifirnhnn
DIVISION OF WATER QUALITY
PROJECT DATA SHEET
Project Name
Bob King Mercedes Showroom and Service Center
Permit Number
920913 Modification
Location
New Hanover County
Applicant
Mr Robert S King, Owner
Mailing Address
Bob King Pontiac-GMC, Inc
5115 New Centre Drive _
Wilmington, North Carolina 28403
Application Date
October 25, 1996
Water Body Receiving Stormwater Runoff
Bradley Creek
Classification of Water Body
"SC HQW #"
If Class SA, chlonde sampling results
N/A
Pond Depth
5 feet
Permanent Pool Elevation
37 5 MSL
Total Impervious Surfaces Allowed
54,980 square feet
Green Area entering Pond
24,299 square feet
Required Surface Area
3,928 square feet
Provided Surface Area
4,000 square feet
Required Storage Volume
4,454 cubic feet
Provided Storage Volume
5,207 cubic feet
Temporary Storage Elevation
38 7 MSL
Controlling Orifice
V pipe
RJ
State Stormwater Management Systems
Permit No SW891091IMod-finshon
4 The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans
5 The permittee is responsible for verifying that the proposed built -upon area does not exceed the allowable bwlt-upon
area
6 The following items will require a modification to the permit
a Any revision to the approved plans, regardless of size
b Project name change
c Transfer of ownership
d Redesign or addition to the approved amount of built -upon area
e Further subdivision of the project area
f Filling in, altering, or piping of any vegetative conveyance shown on the approved plan
In addition, the Director may determine that other revisions to the project should require a modification to the permit
The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements
of the permit Within the time frame specified in the notice, the permittee shall submit a written time schedule to the
Director for modifying the site to meet minimum requirements The perrmuce shall provide copies of revised plans
and certification in writing to the Director that the changes have been made
H. SCHEDULE OF COMPLIANCE
The permittee will comply with the following schedule for construction and maintenance of the stormwater management
system
The stormwater management system shall be constructed in it's entirety, vegetated and operational for it's
intended use prior to the construction of any built -upon surface except roads
During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired
immediately
The perrruttee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater
system functions at optimum efficiency The approved Operation and Maintenance Plan must be followed in it's entirety
and maintenance must occur at the scheduled intervals including, but not limited to
a Semiannual scheduled inspections (every 6 months)
b Sediment removal
c Mowing and revegetation of side slopes
d Immediate repair of eroded areas
e Maintenance of side slopes in accordance with approved plans and specifications
f Debris removal and unclogging of outlet structure, orifice device and catch basins and piping
g Access to the outlet structure must be available at all times
Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ
The records will indicate the date, activity, name of person performing the work and what actions were taken
This pernut shall become voidable unless the facilities are constructed in accordance with the conditions of this permit,
the approved plans and specifications, and other supporting data
State Stormwater Management Systems
Permit No. SW9 990011 Mckilfin.rjon
Upon completion of construction, prior to Issuance of a Certificate of Occupancy, and prior to operation of this
perriutted facility, a certification must be received from an appropriate designer for the system installed certifying that
the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other
supporting documentation Any deviations from the approved plans and specifications must be noted on the
Certification
A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years
from the date of the completion of construction
III GENERAL CONDITIONS
This pernut is not transferable In the event there is a desire for the facilities to change ownership, or there is a name
change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by
an application fee, documentation from the parties involved, and other supporting materials as may be appropriate
The approval of this request will be considered on its merits and may or may not be approved
Failure to abide by the conditions and limitations contained in this permit may subject the Perrmttee to enforcement
action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215 6(a) to 143-
215 6(c)
The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules,
regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have
jurisdiction
In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee
shall take immediate corrective action, including those as may be required by this Division, such as the construction
of additional or replacement stormwater management systems
The permittee grants DEHNR Staff permission to enter the property for the purpose of inspecting all components of
the permitted stormwater management facility
The permit may be modified, revoked and reissued or terminated for cause The filing of a request for a permit
modification, revocation and reissuance or termination does not stay any permit condition
Permit issued this the 14th day of November, 1996
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
V 1 "
A Pr to oward, Jr , P E , Director
Divis of Water Quality
By Authority of the Environmental Management Commission
Permit Number SW8 920913 Modification
State Stormwater Management Systems
Parma Nn SW8 920913 Modificahnn
Bob King Mercedes Showroom and Service Center
Stormwater Permit No SW8 920913 Modification
New Hanover County
Engineer's Certification
1, , as a duly registered Professional Engineer in the State of North Carolina,
having been authorized to observe (periodically/weekly/full time) the construction of the project,
for (Project Owner) hereby state that, to the best of my abilities, due care and
diligence was used in the observation of the project construction such that the construction was observed to be built within
substantial compliance and intent of the approved plans and specifications
Noted deviations from approved plans and specification
Signature
Registration Number
Date
W
DETENTION POND ANALYSIS
PROJECT # SW8 920913 Modification
PROJECT NAME Bob King Mercedes
Bti Drainage Basin reek
FILE NAME S \WQS\POND\920913 WK1
REVIEWE ARL
DATE 13-Nov-96
Class SC:5WNQi✓Chlorides N/A
Site Area 79279 square feet
Drainage Area 79279 square feet
Area in Acres 1 81999541 acres
IMPERVIOUS AREA
Runoff Coefficient
Buildings 12925 1
Concrete 0 095
Asphalt 42055 095
TOTAL 54980 square feet
% IMPERVIOUS 69 35%
SURFACE AREA CALCULATION
SA/DA
Req SA
Prov SA
VOLUME CALCULATION
Pond Depth
4 955%
3927 879 square feet
4000 Isquare feet
Green 24299 square feet
Bottom 32 5 MSL
Perm Pool 37 5 MSL
Design Pool 38 7 JMSL
Design SA 4679 square feet
Req Volume 4453 82917 cubic feet
Prov Volume 5207 4 cubic feet
ORIFICE CALCULATION
5 TSS
[From plan Contours]
[From plan Contours]
Rv= 06741502
Avg Head = 0 5791667 ft
0111
Flow Q2, cfs
003013542 Area, in
1 184251
Dia 2, inches
1 227939
Flow Q5, cfs
001205417 Area, in
0 4737
Dia 5, inches
0 776617
Engineer usesl
Area =
0 7853982
in
1 Inches
Q, cfs = 0 0199859
Drawdown
3 0 556702
days
COMMENTS
Surface Area, Volume and Orifice are within Design Guidelines
KLEIN ENGINEERING
AND ASSOCIATES
October 23, 1996
Ms Linda Lewis
NC DEHNR
Division of Environmental Management
Water Quality Section
127 Cardinal Drive Extension
Wilmington, NC 28405-3845
I1322 South 4th Street
OCT 2 5 199fi �w'I (910) 76NC
28401
Re Bob King Mercedes-Benz Showroom and Service Center
(formerly New and Used Car Recon Center)
Modification to Existing Permit No 920913
Dear Ms Lewis
File No 96008
Please find enclosed revisions to the above project number As you know, the actual buildings were
never built and the rear pavement had been constructed as well as the DEM stormwater pond The
enclosed modifications is to combine the prior budding areas into a single building with all drainage
discharging into the pond As indicated on the Drawing, the actual built -upon area for this
modification is less than the prior amount Included for your review are the following
Completed application form
Application fee in the amount of $225
Three (3) copies of the Drawings which include built -upon area Calculations
Should there be any questions concerning the enclosed items or additional copies needed, please feel
free to contact our office
Sincerely,
KLEIN ENGINEERING AND ASSOCIATES
enclosures
cc Mr Bob King
STORMWATER
j� E C E I V E D
OCT 2 51996
PROJ # 2�
11ron
KLEIN ENGINEERING
AND ASSOCIATES
July 15, 1994
322 South 4th Street
Wilmington, NC 28401
(919) 763-7900
File No.- 94004
Ms. Linda Lewis
NC DEHNR
Division of Environmental Management
Water Quality Section JUL 1 9 1994
127 Cardinal Drive Extension
Wilmington, NC 28405-3845
Re: Bob King Pontiac
Stormwater Pond and Drainage System Certification
Project No.: 920913
Dear Linda:
Please find enclosed Engineer's Certification for the above
referenced project. Please note that the certification is for
the stormwater pond and collection system only as requested in
letter from Rick Shiver dated June 17, 1994.
Please note that the rear portion of the site has been
substantially completed while the front portion is currently
under redesign to eliminate the showroom. We will keep your
office updated for permit revisions as the project develops.
Furthermore, upon completion of the site improvements, our office
will forward a final certification on the project as required.
Sincerely,
KLEIN ENGINEERING AND ASSOCIATES
enclosure
cc: Mr Robert S. King
JUL 19 11994
DEM
PROJ 92OR c 3
State of North Carolina
Department of Environment, Health, and Natural Resources
Wilmington Regional Office
James B Hunt, Jr , Governor DIVISION OF ENVIRONMENTAL MANAGEMENT Bob Jamieson
Jonatban B Howes, Secretary Regional Manager
July 26, 1993
Mr Robert S King, President
Bob King Pontiac-GMC, Inc
5115 New Centre Drive
Wilmington, North Carolina 28406
Subject REQUEST FOR ENGINEER'S CERTIFICATION
Stormwater Project No 920913
Bob King Pontiac
New Hanover County
Dear Mr King
On October 28, 1992, the Division of Environmental Management Issued a Certification of
Compliance with Stormwater Regulations for Bob King Pontiac Stormwater Regulation 15A NCAC
2H 1003(k)(3) stipulates the following
Upon completion of construction, a registered professional appropriate for the type of
Stormwater system designed must certify that the system was inspected during construction
and was constructed in substantial conformity with plans and specifications reviewed by
the Division and complies with the requirements of this rule
As of this date, our records indicate the required engineer's certification has not been received
Operation of the stormwater system prior to submission of the required certification is in violation of
NCAC 211 1003(1) in accordance with NCGS 143-215 6 Since construction of the subject project has
been completed, please submit the attached Engineer's Certification immediately Construction is
considered complete at the time the project is occupied by an owner or tenant for its intended use
At the last inspection the pond construction was complete, however, the associated buildmgs and
parking had not been constructed The Engineer's Certification will certify that the pond is constructed
in accordance with the approved plans A conditional certification can be accepted with full certification
at a later date when all buildings and parking are finished
127 Cardinal Drive Extension, Wilmington, N C 28405 3845 • Telephone 919 395-3900 • Fax 919 350-2004
An Equal Opportunity Affirmative Action Employer
Mr King
July 26, 1993
Stormwater Project No 920913
3900
If you have any questions concerning this matter, please call Ms Linda Lewis or me at (919) 395-
Sincerely,
Dave Adkins
Water Quality Supervisor
DA/arl S \WQS\STORMWAT\PEREQ\920913 JUL
cc Mr Sky Conklin, New Hanover County Inspections
Mr John Klein, P E
(2) Linda Lewis
Central Files