Loading...
HomeMy WebLinkAboutSW8920913_HISTORICAL FILE_19961114STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO SW8 g20913 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ® HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 0ow ill'} YYYYMMDD State of North Carolina Department of Environment, Health and Natural Resources Division of Water Quality James B Hunt, Jr , Governor Jonathan B Howes, Secretary A Preston Howard, Jr , P E , Director Mr Robert S King, Owner Bob King Pontiac-GMC, Inc 5115 New Centre Drive Wilmington, North Carolina 28403 Dear Mr King A4� EDFEE HNR November 14, 1996 Subject Permit No SW8 920913 Modification Bob King Mercedes Showroom and Service Center High Density Commercial Stormwater Project New Hanover County The Wilmington Regional Office received a modification to the Stormwater Management Pernut Apphcation for Bob King Mercedes Showroom and Service Center on October 25, 1996 Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H 1000 We are forwarding Permit No SW8 920913 Modification dated November 14, 1996, for the construction of Bob King Mercedes Showroom and Service Center This permit supercedes the one issued to you on October 28, 1992 This permit shall be effective from the date of issuance until November 14, 2006, and shall be subject to the conditions and limitations as specified therein Please pay special attention to the Operation and Maintenance requirements in this permit Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems If any parts, requirements, or limitations twntamed in this permit are unacceptable, you have the right to request an ajudicatory hearing upon written request within thirty (30) days following receipt of this permit This request must be in the form of a written petition, conforming to Chapter 150B of the North Carohm General Statutes, and filed with the Office of Admimstranve Hearings, P O Drawer 27447, Raleigh, NC 27611-7447 Unless such demands are made this permit shall be final and binding If you have any questions, or need additional information concerning this matter, please contact Linda Lewis, or me at (910) 395-3900 Sincerely, p tC/�ixisk����''l Ken Eagleson V Regional Water Quality Supervisor KE/arl S \WQS\STORMWAT\PERMIT\920913 NOV cc John Klein, P E Tony Roberts, New Hanover County Inspections Beth Easley, New Hanover County Engineering Linda Lewis %;Wdimng[on Regional Office David Mayes, P E Central Files P 0 Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer State Stormwater Management Systems Permit No. SWR 990919 ModificAtmn STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES DIVISION OF WATER QUALITY HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Bob King Pontiac-GMC, Inc Bob King Mercedes Showroom and Service Center New Hanover County FOR THE construction, operation and maintenance of a Detention Pond in comphance with the provisions of 15A NCAC 2H 1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit This permit shall be effective from the date of issuance until November 14, 2006 and shall be subject to the following specified conditions and limitations I. DESIGN STANDARDS This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data 2 This stormwater system has been approved for the management of stormwater runoff as described on page 3 of thus permit, the Project Data Sheet The stormwater control has been designed to handle the runoff from 54,980 square feet of impervious area 3 Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit P7 State Stormwater Management Systems Permit No SWR 92Q913 Modifirnhnn DIVISION OF WATER QUALITY PROJECT DATA SHEET Project Name Bob King Mercedes Showroom and Service Center Permit Number 920913 Modification Location New Hanover County Applicant Mr Robert S King, Owner Mailing Address Bob King Pontiac-GMC, Inc 5115 New Centre Drive _ Wilmington, North Carolina 28403 Application Date October 25, 1996 Water Body Receiving Stormwater Runoff Bradley Creek Classification of Water Body "SC HQW #" If Class SA, chlonde sampling results N/A Pond Depth 5 feet Permanent Pool Elevation 37 5 MSL Total Impervious Surfaces Allowed 54,980 square feet Green Area entering Pond 24,299 square feet Required Surface Area 3,928 square feet Provided Surface Area 4,000 square feet Required Storage Volume 4,454 cubic feet Provided Storage Volume 5,207 cubic feet Temporary Storage Elevation 38 7 MSL Controlling Orifice V pipe RJ State Stormwater Management Systems Permit No SW891091IMod-finshon 4 The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans 5 The permittee is responsible for verifying that the proposed built -upon area does not exceed the allowable bwlt-upon area 6 The following items will require a modification to the permit a Any revision to the approved plans, regardless of size b Project name change c Transfer of ownership d Redesign or addition to the approved amount of built -upon area e Further subdivision of the project area f Filling in, altering, or piping of any vegetative conveyance shown on the approved plan In addition, the Director may determine that other revisions to the project should require a modification to the permit The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements The perrmuce shall provide copies of revised plans and certification in writing to the Director that the changes have been made H. SCHEDULE OF COMPLIANCE The permittee will comply with the following schedule for construction and maintenance of the stormwater management system The stormwater management system shall be constructed in it's entirety, vegetated and operational for it's intended use prior to the construction of any built -upon surface except roads During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately The perrruttee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency The approved Operation and Maintenance Plan must be followed in it's entirety and maintenance must occur at the scheduled intervals including, but not limited to a Semiannual scheduled inspections (every 6 months) b Sediment removal c Mowing and revegetation of side slopes d Immediate repair of eroded areas e Maintenance of side slopes in accordance with approved plans and specifications f Debris removal and unclogging of outlet structure, orifice device and catch basins and piping g Access to the outlet structure must be available at all times Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ The records will indicate the date, activity, name of person performing the work and what actions were taken This pernut shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data State Stormwater Management Systems Permit No. SW9 990011 Mckilfin.rjon Upon completion of construction, prior to Issuance of a Certificate of Occupancy, and prior to operation of this perriutted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation Any deviations from the approved plans and specifications must be noted on the Certification A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction III GENERAL CONDITIONS This pernut is not transferable In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate The approval of this request will be considered on its merits and may or may not be approved Failure to abide by the conditions and limitations contained in this permit may subject the Perrmttee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215 6(a) to 143- 215 6(c) The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems The permittee grants DEHNR Staff permission to enter the property for the purpose of inspecting all components of the permitted stormwater management facility The permit may be modified, revoked and reissued or terminated for cause The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition Permit issued this the 14th day of November, 1996 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION V 1 " A Pr to oward, Jr , P E , Director Divis of Water Quality By Authority of the Environmental Management Commission Permit Number SW8 920913 Modification State Stormwater Management Systems Parma Nn SW8 920913 Modificahnn Bob King Mercedes Showroom and Service Center Stormwater Permit No SW8 920913 Modification New Hanover County Engineer's Certification 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications Noted deviations from approved plans and specification Signature Registration Number Date W DETENTION POND ANALYSIS PROJECT # SW8 920913 Modification PROJECT NAME Bob King Mercedes Bti Drainage Basin reek FILE NAME S \WQS\POND\920913 WK1 REVIEWE ARL DATE 13-Nov-96 Class SC:5WNQi✓Chlorides N/A Site Area 79279 square feet Drainage Area 79279 square feet Area in Acres 1 81999541 acres IMPERVIOUS AREA Runoff Coefficient Buildings 12925 1 Concrete 0 095 Asphalt 42055 095 TOTAL 54980 square feet % IMPERVIOUS 69 35% SURFACE AREA CALCULATION SA/DA Req SA Prov SA VOLUME CALCULATION Pond Depth 4 955% 3927 879 square feet 4000 Isquare feet Green 24299 square feet Bottom 32 5 MSL Perm Pool 37 5 MSL Design Pool 38 7 JMSL Design SA 4679 square feet Req Volume 4453 82917 cubic feet Prov Volume 5207 4 cubic feet ORIFICE CALCULATION 5 TSS [From plan Contours] [From plan Contours] Rv= 06741502 Avg Head = 0 5791667 ft 0111 Flow Q2, cfs 003013542 Area, in 1 184251 Dia 2, inches 1 227939 Flow Q5, cfs 001205417 Area, in 0 4737 Dia 5, inches 0 776617 Engineer usesl Area = 0 7853982 in 1 Inches Q, cfs = 0 0199859 Drawdown 3 0 556702 days COMMENTS Surface Area, Volume and Orifice are within Design Guidelines KLEIN ENGINEERING AND ASSOCIATES October 23, 1996 Ms Linda Lewis NC DEHNR Division of Environmental Management Water Quality Section 127 Cardinal Drive Extension Wilmington, NC 28405-3845 I1322 South 4th Street OCT 2 5 199fi �w'I (910) 76NC 28401 Re Bob King Mercedes-Benz Showroom and Service Center (formerly New and Used Car Recon Center) Modification to Existing Permit No 920913 Dear Ms Lewis File No 96008 Please find enclosed revisions to the above project number As you know, the actual buildings were never built and the rear pavement had been constructed as well as the DEM stormwater pond The enclosed modifications is to combine the prior budding areas into a single building with all drainage discharging into the pond As indicated on the Drawing, the actual built -upon area for this modification is less than the prior amount Included for your review are the following Completed application form Application fee in the amount of $225 Three (3) copies of the Drawings which include built -upon area Calculations Should there be any questions concerning the enclosed items or additional copies needed, please feel free to contact our office Sincerely, KLEIN ENGINEERING AND ASSOCIATES enclosures cc Mr Bob King STORMWATER j� E C E I V E D OCT 2 51996 PROJ # 2� 11ron KLEIN ENGINEERING AND ASSOCIATES July 15, 1994 322 South 4th Street Wilmington, NC 28401 (919) 763-7900 File No.- 94004 Ms. Linda Lewis NC DEHNR Division of Environmental Management Water Quality Section JUL 1 9 1994 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Re: Bob King Pontiac Stormwater Pond and Drainage System Certification Project No.: 920913 Dear Linda: Please find enclosed Engineer's Certification for the above referenced project. Please note that the certification is for the stormwater pond and collection system only as requested in letter from Rick Shiver dated June 17, 1994. Please note that the rear portion of the site has been substantially completed while the front portion is currently under redesign to eliminate the showroom. We will keep your office updated for permit revisions as the project develops. Furthermore, upon completion of the site improvements, our office will forward a final certification on the project as required. Sincerely, KLEIN ENGINEERING AND ASSOCIATES enclosure cc: Mr Robert S. King JUL 19 11994 DEM PROJ 92OR c 3 State of North Carolina Department of Environment, Health, and Natural Resources Wilmington Regional Office James B Hunt, Jr , Governor DIVISION OF ENVIRONMENTAL MANAGEMENT Bob Jamieson Jonatban B Howes, Secretary Regional Manager July 26, 1993 Mr Robert S King, President Bob King Pontiac-GMC, Inc 5115 New Centre Drive Wilmington, North Carolina 28406 Subject REQUEST FOR ENGINEER'S CERTIFICATION Stormwater Project No 920913 Bob King Pontiac New Hanover County Dear Mr King On October 28, 1992, the Division of Environmental Management Issued a Certification of Compliance with Stormwater Regulations for Bob King Pontiac Stormwater Regulation 15A NCAC 2H 1003(k)(3) stipulates the following Upon completion of construction, a registered professional appropriate for the type of Stormwater system designed must certify that the system was inspected during construction and was constructed in substantial conformity with plans and specifications reviewed by the Division and complies with the requirements of this rule As of this date, our records indicate the required engineer's certification has not been received Operation of the stormwater system prior to submission of the required certification is in violation of NCAC 211 1003(1) in accordance with NCGS 143-215 6 Since construction of the subject project has been completed, please submit the attached Engineer's Certification immediately Construction is considered complete at the time the project is occupied by an owner or tenant for its intended use At the last inspection the pond construction was complete, however, the associated buildmgs and parking had not been constructed The Engineer's Certification will certify that the pond is constructed in accordance with the approved plans A conditional certification can be accepted with full certification at a later date when all buildings and parking are finished 127 Cardinal Drive Extension, Wilmington, N C 28405 3845 • Telephone 919 395-3900 • Fax 919 350-2004 An Equal Opportunity Affirmative Action Employer Mr King July 26, 1993 Stormwater Project No 920913 3900 If you have any questions concerning this matter, please call Ms Linda Lewis or me at (919) 395- Sincerely, Dave Adkins Water Quality Supervisor DA/arl S \WQS\STORMWAT\PEREQ\920913 JUL cc Mr Sky Conklin, New Hanover County Inspections Mr John Klein, P E (2) Linda Lewis Central Files