HomeMy WebLinkAboutSW8100315_HISTORICAL FILE_20100610STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PER:TN. SW8 I (� p315 DOC ElCURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE Zo 1 o O l0 l0 YYYYMMDD NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H Sullins Governor Director June 10, 2010 Woodrow W Sullivan, Chief Fender Volunteer EMS & Rescue, Inc 14388 NC Hwy 210 Rocky Point, NC 28457 Subject: State Stormwater Management Permit No. SW8100315 Pender EMS High Density Commercial Wet Detention Pond Project Pender County Dear Mr Sullivan Dee Freeman Secretary The Wilmington Regional Office received a complete Stormwater Management Permit Application for Pender EMS on May 27, 2010. Staff review of the plans and specifications has determined that the protect, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H 1000 and Session Law 2008-211 We are forwarding Permit No. SW8 100315 dated June 10, 2010 for the construction, operation, and maintenance of the subject protect This permit shall be effective from the date of issuance until June 10, 2020, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adtudlcatory hearing upon written request within thirty (30) days following receipt of this permit This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P O Drawer 27447, Raleigh, NC 27611-7447 Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Steve Pusey, or me at (910) 796-7215 Sincerely, ict Georgette Cott Stormwater Supervisor Division of Water Quality GDS/ sgp S.\WQS\STORMWATER\PERMIT\100315.jun10 cc J Rueger Hauck, Jr —Walton Engineering Chad McEwen, Town of Burgaw Pender County Building Inspections Steve Pusey CWdmington_Regional-Offices C—entraf Files Wilmington Regional Office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 7�TOne t, � Phone 910-796-7215 \ FAX 910-350-2004\ Customer Service 1.877-623-6748 i orth(Cawlina Internet mmaterquality org a'altmi //,, An Equal Opportunity 1 Affirmative Action Employer (/ V`L hL(`J State Stormwater Management Systems Permit No SW8 100315 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY COMMERCIAL DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Woodrow W. Sullivan & Pender Volunteer EMS & Rescue, Inc. Pender EMS Near intersection of Ridgewood Ave. & Hwy 117, Burgaw, Pender County FOR THE construction, operation and maintenance of one (1) wet detention pond in compliance with the provisions of 15A NCAC 2H 1000 and Session Law 2008-211 (hereafter collectively referred to as the "stormwater rules') the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit This permit shall be effective from the date of issuance until June 10, 2020, and shall be subject to the following specified conditions and limitations. I. DESIGN STANDARDS This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data 2. This stormwater system has been approved for the management of stormwater runoff as described in Section 1.8 on page 3 of this permit The stormwater control has been designed to handle the runoff from 44,001 square feet of impervious area 3 A 50' wide vegetative buffer must be provided adjacent impounded structures, streams, rivers and tidal waters 4 The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans 5. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. 6 The runoff from all built -upon area within the permitted drainage area(s) of this project must be directed into the permitted stormwater control system. Page 2 of 7 State Stormwater Management Systems Permit No. SW8 100315 7. The following design criteria have been provided in the wet detention pond and must be maintained at design condition: a Drainage Area, acres: Onsite, ft : Offsite, ft2: b Total Impervious Surfaces, ft2. Onsite, ft Offsite, ft2: c Design Storm, inches: d Average Pond Design Depth, feet: e. TSS removal efficiency f. Permanent Pool Elevation, FMS6: g Permanent Pool Surface Areq, ft h. Permitted Storage Volume, ft : i. Temporary Storage Elevation, FMSL: j Pre-dev. 1 yr-24 hr discharge rate, cfs- k. Controlling Orifice: I. Orifice flowrate, cfs M. Permitted Forebay Volume, ft3: n Fountain Horsepower o. Receiving Stream/River Basin: p Stream Index Number: q. Classification of Water Body: II. SCHEDULE OF COMPLIANCE 223 97,241 0 44,001 44,001 0 15 3 90% 40 6,005 7,236 at temporary pool elev. 41 0.1 5 x'/2 0 holes 0.02 2,485 N/A NE Cape Fear / Cape Fear 18-74-(29.5) "C; Sw" The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. The permittee shall at all time provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months) b Sediment removal. C. Mowing and re -vegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications f. Debris removal and unclogging of outlet structure, orifice device, flow spreader, catch basins and piping. g Access to the outlet structure must be available at all times. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. The facilities shall be constructed as shown on the approved plans This permit shall become void unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. Page 3 of 7 State Stormwater Management Systems Permit No SW8 100315 6. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification A modification may be required for those deviations. 7. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility 8. Access to the stormwater facilities for inspection and maintenance shall be maintained via appropriate recorded easements at all times. 9. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc b. Project name change. C. Transfer of ownership. d Redesign or addition to the approved amount of built -upon area or to the drainage area e Further development, subdivision, acquisition, lease or sale of any, all or part of the project area The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought f Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 10. Prior to the construction of any permitted future areas shown on the approved plans, the permittee shall submit final site layout and grading plans to the Division for approval. 11. A copy of the approved plans and specifications shall be maintained on file by the Permittee at all times 12 The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made II. GENERAL CONDITIONS This permit is not transferable to any person or entity except after notice to and approval by the Director In the event of a change of ownership, or a name change, the permittee must submit a completed Name/Ownership Change Form signed by both parties, to the Division of Water Quality, accompanied by the supporting documentation as listed on page 2 of the form. The approval of this request will be considered on its merits and may or may not be approved. Page 4 of 7 State Stormwater Management Systems Permit No. SW8 100315 2. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. Neither the sale of the project nor the transfer of common area to a third party constitutes an approved transfer of the stormwater permit. 3 Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 4. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. 5. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 6 The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 7. The permit remains in force and effect until modified, revoked, terminated or renewed. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and re - issuance or termination does not stay any permit condition 8. Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 9 Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 10. The permittee shall notify the Division of any name, ownership or mailing address changes at least 30 days prior to making such changes. 11. The permittee shall submit a permit renewal request at least 180 days prior to the expiration date of this permit. The renewal request must include the appropriate documentation and the processing fee. Permit issued this the 10'" day of June, 2010. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION By Authority of the Environmental Management Commission Page 5 of 7 7 DWQ USE ONLY Date Received Fee Paid Permit Number 3—/6- Zo/o SoS.° # //600 Applicable Rules: ❑ Coastal SW -1993 ❑ Coastal SW - 2008 ❑ Ph II - Post Construction (select all that apply) ❑ Non -Coastal SW- HQW/ORW Waters ❑ Universal Stormwater Management Plan ❑ Other WQ Mgmt Plair State of North Carolina Department of Environment and Natural Resources Division of Water QualityCEIT/ STORMWATER MANAGEMENT PERMIT APPLICATIO F( i" B 2O1Q Thu form may be photocopied for use as an original ^ I. GENERAL INFORMATION 1. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): 2. Location of Project (street address): Ridgewood Avenue City:Burgaw County:Pender Zip:28425 3. Directions to project (from nearest major intersection): From the intersection of Hwy 53 & Hwy 117, go about 600' south on Hwy 117 and take a right on Ridgewood Avenue. The subject site is located 381' from the intersection of Hwy 117 & Ridgewood Avenue on the right (currently there is not a street adress listed for this site). 4. Latitude:34° 33' 32.22" N Longitude:77155' 7.32" W of the main entrance to the project. H. PERMIT INFORMATION: 1.a.Specify whether project is (check one): NNew ❑Modification b.If this application is being submitted as the result of a modification to an existing permit, list the existing permit numberNA , its issue date (if known)NA and the status of construction: NNot Started ❑Partially Completed* ❑ Completed* *provide a designer's certification 2. Specify the type of project (check one): ❑Low Density NHigh Density ❑Drains to an Offsite Stormwater System ❑Other 3. If this application is being submitted as the result of a previously returned application or a letter from DWQ requesting a state stormwater management permit application, list the stormwater project number, if assigned, NA and the previous name of the project, if different than currently proposed, NA 4 a. Additional Project Requirements (check applicable blanks; information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748): ❑CAMA Major ❑NPDES Industrial Stormwater NSedimentation/Erosion Control: 2.22 ac of Disturbed Area 0404/401 Permit: Proposed Impacts b.If any of these permits have already been acquired please provide the Project Name, Project/Permit Number, issue date and the type of each permit: i ill. CONTACT INFORMATION 1. a. Print Applicant / Signing Official's name and title (specifically the developer, properly owner, lessee, designated government official, individual, etc. who owns the protect) Apphcant/Organization:Pender Volunteer EMS & Rescue. Inc. Signing Official & Title:Woodrow W. Sullivan - Chief b.Contact information for person listed in item la above Street Address:14388 NC Hwv 210 City:Rocky Point State:NC Zip:28457 Mailing Address (if applicable)-P.O. Box 650 City:Rocky Point State:NC Zip:28457 Phone: (910 ) 675-9198 Fax: (910 ) 675-9169 Email: c. Please check the appropriate box. The applicant listed above is: N The property owner (Skip to Contact Information, item 3a) ❑ Lessee* (Attach a copy of the lease agreement and complete Contact Information, item 2a and 2b below) ❑ Purchaser* (Attach a copy of the pending, sales agreement and complete Contact Information, item 2a and 2b below) ❑ Developer* (Complete Contact Information, item 2a and 2b below.) 2 a Print Property Owner's name and title below, if you are the lessee, purchaser or developer. (This is the person who owns the property that the project is located on): Property Owner/Organization: Signing Official & Title: b.Contact information for person listed in item 2a above: Street Address - City: State, Mailing Address (if applicable): City: State, Phone: ( ) Fax: 3. a. (Optional) Print the name and title of another contact such as the project's construction supervisor or other person who can answer questions about the project: Other Contact Person/Orgam7ation: Signing Official & Title: b.Contact information for person listed in item 3a above: Mailing Address: Phone: Fax: 4. Local jurisdiction for building permits: Town of Burgaw Point of ContactChad McEwen Phone #: (910 ) 259-2151 IV. PROJECT INFORMATION 1 In the space provided below, briefly summarize how the stormwater runoff will be treated. Stormwater will be conveyed to a stormwater wet detention pond and forebay via grass lined swales 2. a. If claiming vested rights, identify the supporting documents provided and the date they were approved: ❑ Approval of a Site Specific Development Plan or PUD Approv ❑ Valid Building Permit Issued a e. D ❑ Other: Date: b.ldentify the regulahon(s) the project has been designed in accordance with: ® Coastal SW -1995 El Ph II - Post Construction $Y. 3. Stormwater runoff from this project drams to the Cane Fear a basin. 4. Total Property Area: 3.41 acres 5. Total Coastal Wetlands Area: 0 acres 6. Total Surface Water Area: 0 acres 7. Total Property Area (4) - Total Coastal Wetlands Area (5) - Total Surface Water Area (6) = Total Project Area*:3.41 acres ' Total project area shall be calculated to exclude the following. the normal pool of impounded structures, the area between the banks of streams and rivers, the area below the Normal High Water (NNW) line or Mean High Water (MHW) line, and coastal wetlands landward from the NHW (or MHW) line The resultant project area is used to calculate overall percent built upon area (BL IA). Non -coastal wetlands landward of the NHW (or MHW) line may be included in the total project area 8. Project percent of impervious area: (Total Impervious Area / Total Project Area) X 100 = 29.6 % 9. How many drainage areas does the project have?3 (For high density, count 1 for each proposed engineered stormwater BMP. For low density and other projects, use 1 for the whole property area) 10. Complete the following information for each drainage area identified in Project Information item 9. If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. Basin Information Drainage Area 1 Drainage Area 2 Drainage Area 3 Drainage Area _ Receiving Stream Name NE Cape Fear NE Cape Fear NE Cape Fear Stream Class * C ; SW C ; SW C ; SW Stream Index Number * 18-74-(29.5) 18-74-(29.5) 18-74-(29.5) Total Drainage Area (sf) 28721 26581 41939 On -site Drainage Area (so 28721 26381 41939 Off -site Drainage Area (sf) 1 0 0 0 Proposed Impervious Area" sf) 22190 19953 1858 % Impervious Area" total 77.2 751 4.43 Impervious— Surface Area Drainage Area 1 Drainage Area 2 Drainage Area 3 Drama e Area On -site Buildings/Lots (sf) 4906 10395 0 On -site Streets (so 0 0 0 On -site Parking (so 16760 8822 0 On -site Sidewalks (so 524 736 1858 Other on -site (sf) 0 0 0 Future (sf) 0 0 0 Off -site (sf) 0 0 10 Existing BUA*** (sf) 0 0 0 Total (so: 22190 19953 1858 Stream Class and Index Number can be determined at. http11h2o enr state.nc.us/buns/reporWrMortsWB html 'Report only that amount of existing BUA that will remain after development Do not report any existing BUA that is to be removed and which will be replaced by new B UA. 11. How was the off -site impervious area listed above determined? Provide documentation. CADD Projects in Union County: Contact DWQ Central Office staff to check if the project is located within a Threatened & Endangered Species watershed that maybe subject to more stringent stormwater requirements as per NCAC 02B 0600 V. SUPPLEMENT AND O&M FORMS The applicable state stormwater management permit supplement and operation and maintenance (O&M) forms must be. submitted for each BMP specified for this project. The latest versions of the forms can be downloaded from http://h2o.enr.state.nc.us/su/­bmp—forms.htm. VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below. A detailed application instruction sheet and BMP checklists are available from http://h2o.enr.state.nc.us/su/bmp forms.hlm. The complete application package should be submitted to the appropriate DWQ Office. (The appropriate office may be found by locating project on the interactive online map at http//h2o.enr.state.nc.us/su/msi_maps.htm.) Please indicate that the following required information have been provided by initialing in the space provided for each item. All original documents MUST be signed and initialed in blue ink. Download the latest versions for each submitted application package from http://h2o.enr.state.nc.us/sic/bmp forms.htm. Initials 1. Original and one copy of the Stormwater Management Permit Application Form. C21: 2. Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants Nt` Form. (if required as per Part VII below) 3. Original of the applicable Supplement Form(s) (sealed, signed and dated) and O&M`} agreement(s) for each BMP. 4. Permit application processing fee of $505 payable to NCDENR. (For an Express review, refer to J-Qk� http://www.envhelp.org/pages/onestopexpress.htmi for information on the Express program and the associated fees. Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required dpphcation meeting.) 5. A detailed narrative (one to two pages) describing the stormwater treatment/management for Sixu 6. A USGS map identifying the site location. if the receiving stream is reported as class SA or the sea receiving stream drams to class SA waters within 1h mile of the site boundary, include the 1/2 mile radius on the map 7. Sealed, signed and dated calculations 8. Two sets of plans folded to 8 5" x 14" (sealed, signed, & dated), including: a Development/Project name. b. Engineer and firm. T _ c. Location map with named streets and NCSR numbers C�;�` d. Legend. e. North arrow. f. Scale. AR 161010 g. Revision number and dates. Bj'. h. Identify all surface waters on the plans by delineating the norm tion of CC impounded structures, the banks of streams and rivers, the MHW or NHW_lindal waters, and any coastal wetlands landward of the MHW or N14W lines. • Delineate the vegetated buffer landward from the normal pool elevation of impounded structures, the banks of streams or rivers, and the MHW (or NHW) of tidal waters. i. Dimensioned property/project boundary with bearings & distances. 1. Site Layout with all BUA identified and dimensioned k. Existing contours, proposed contours, spot elevations, f cashed floor elevations. 1. Details of roads, drainage features, collection systems, and stormwater control measures. in. Wetlands delineated, or a note on the plans that none exist. (Must be delineated by a qualified person Provide documentation of quahhcalions and identify the person who made the determination on the plans. n. Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations o. Drainage areas delineated (included in the main set of plans, not as a separate document). s2n SRtt p. Vegetated buffers (where required) 9. Copy of any applicable soils report with the associated SHWT elevations (Please identify zaa elevations in addition to depths) as well as a map of the bonng locations with the existing elevations and boring logs. Include an 8.5"x1T' copy of the NRCS County Soils map with the project area clearly delineated. For projects with infiltration BMPs, the report should also include the soil type, expected infiltration rate, and the method of determining the infiltration rate. (Infiltration Devices submitted to WiRO: Schedule a site visit far DWQ to verify the SFIWr prior to submittal, (910) 796-7378 ) 10. A copy of the most current property deed. Deed book: 3668 Page No 0194 ttw 11. For corporations and limited liability corporations (LLC). Provide documentation from the NC Secretary of State or other official documentation, which supports the titles and positions held by the persons listed in Contact Information, item la, 2a, and/or 3a per NCAC 2H 1003(e). The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State, otherwise the application will be returned http //www.secretary.state.nc.us/Corporations/CSearch.aspxx VH. DEED RESTRICTIONS AND PROTECTIVE COVENANTS For all subdivisions, outparcels, and future development, the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot. If lot sires vary significantly or the proposed BUA allocations vary, a table listing each lot number, lot size, and the allowable built -upon area must be provided as an attachment to the completed and notarized deed restriction form. The appropriate deed restrictions and protective covenants forms can be downloaded from http://h2o ennstate.nc.us/su/bmp forms.htmkdeed restrictions. Download the latest versions for each submittal. In the instances where the applicant is different than the properly owner, it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded. By the notarized signature(s) below, the permit holder(s) certify that the recorded property restrictions and protective covenants for this project, if required, shall include all the items required in the permit and listed on the forms available on the website, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DWQ, and that they will be recorded prior to the sale of any lot. VIII. CONSULTANT INFORMATION AND AUTHORIZATION Applicant: Complete this section if you wish to designate authority to another individual and/or firm (such as a consulting engmeer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional information). Consulting Engineer:Mark Walton Consulting Firm: Walton Engineering Mailing Address.P.O. Box 895 Cily:Burgaw Phone- (910 ) 2594800 Email:mark@waltonenaneenng.net State:NC Zip:28425 Fax: (910 ) 259-1779 IX. PROPERTY OWNER AUTHORIZATION (if Contact Information, item 2 has been filled out, complete this section) 1, (print or type name of person listed in Contact Information, item 2a) , certify that I own the property identified in this permit application, and thus give permission to (print or type name of person listed in Contact Information, item la) with (print or type name of organization listed in Contact Information, item 1b) to develop the project as currently proposed. A copy of the lease agreement or pending property sales contract has been provided with the submittal, which indicates the party responsible for the operation and maintenance of the stormwater system. F2ECETVFID MAR 16 2010 BY: As the legal property owner I acknowledge, understand, and agree by my signature below, that if my designated agent (entity listed in Contact Information, item 1) dissolves their company and/or cancels or defaults on their lease agreement, or pending, sale, responsibility for compliance with the DWQ Slormwater permit reverts back to me, the property owner. As the property owner, it is my responsibility to notify DWQ immediately and submit a completed Name/Ownership Change Form within 30 days; otherwise I will be operating a stormwater treatment facility without a valid permit. I understand that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statue 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $25,000 per day, pursuant to NCGS 143-215.6. a Notary Public for the State of do hereby certify that before me this _ day of County of personally appeared . and acknowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, SEAL My commission X. APPLICANT'S CERTIFICATION RECEIVED MAR 16 2010 BY: 1, (print or type name of person listed in Contact Information, item 2) Woodrow W. Sullivan 1Z certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conforma%e with the approved plans, that the required deed restrictions and protective covenants will be recorded, an that the proposed project complies with the requirements of the applicable stormwater rules under 15A NC C 2H;1000, SL 2006-246 (Ph II - Post Construction) or SL 2008-211. Signature: j�% �1 7� A,�[ //4-- `Jr— Date: 9 /d 11 �hR 2 �-t_Q_ H!d' f i n1 a Notary Public forthe Stale of NC- . County of i Pt -& . do hereby certify that WDL dfoW W - S5o I kyan 1l- personally appeared before me this 1�5 day of Y �W c=b , and ackn wledge a due uti ex on of the application for a stormwater permit. Witness my hand and official seal, 7 TEAL Vy commission expires 0 �0-,_�26/o WALTON ENaiNEERIN June 08, 2010 Mr Steve Pusey NC DENR Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Re Stormwater Permit Application, Pender EMS Dear Mr Pusey, Enclosed is the additional information that you had requested concerning the state stormwater permit application for Pender EMS I added the width of the permanent pool to both the plan view and detail The lengths are correct on both the plan view and the detail view The detail view is broken down into line segment lengths to illustrate the radius lengths I have added the total length and width measurements to the detail view so it will better compliment the plan view drawing The 113' length that you had questioned, was just the length of the main bay of the permanent pool and did not include the forebay (37.5') When added together you get the total permanent pool length of 151 5' (37.5'Forebay + 1'Land bridge + 113'Mam Bay = 151.5') If you have any questions or need any additional information, please feel free to contact me at 910-259-4800 or rue er waltonen ing eering net Thanks for your time) JUN 0 8 Z51Z Sincerely, (/ Rueger Houck Jr !/v Environmental Scientist Walton Engineering Tel 910-2594800 PO Box 895, Burgaw, North Carohna, 28425 Fax 910-259-1779 WALTON ENGINEERIN June 03, 2010 Mr Steve Pusey NC DENR Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Re Stormwater Permit Application, Pender EMS Dear Mr Pusey, Enclosed is the additional information that you had requested concerning the state stormwater permit application for Pender EMS If you have any questions or need any additional information, please feel free to contact me at 910-259-4800 or rueeerna,waltonen ing eermg net Thanks for your time! Sincere� J� Rueger Houck Jr Environmental Scienti Walton Engineering JUN 0 4 1010 Tel 910-2594800 PO Box 895, Bwgaw, North Carolina, 28425 Fax 910-259-1779 Pusey, Steven From: Pusey, Steven Sent: Tuesday, June 01, 2010 4 02 PM To: 'J Rueger Houck' Subject: Pender EMS Importance: High Rueger, I thought we were finished, but I still need a little more information on your drawings for this project. See requirements below: 1. Basic dimensions on the parking lot such as parking space width (typ.), parking lot overall dimensions, driveway widths, sidewalk widths, concrete pad overall dimensions, helipad dimension. 2. Square footage of each building labeled next to FFE label. 3. Length and radius of each line and arc of the permanent pool contour. I hope you can get this finalized soon. Please let me know the earliest date you can provide two (2) revised drawing sets. Please call me tomorrow afternoon so that we can confirm a due date, and whether any other information is needed. Thanks, Steele f"ffesl Environmental Engineer NC DENR - Division of Water Quality Surface Water Protection -Stormwater Tel (910) 796 7215 Fax. (910) 350-2004 E-mail: Steven Pusey@ncdenr gov E-mail correspondence to and from this address may be subject to the NC Public Records Law and may be disclosed to third parties 6�Z/iv C�D G i jo, va e �s 1 WALTON ENGINEERIN May 27, 2010 Mr Steve Pusey NC DENR Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Re. Stormwater Permit Application, Pender EMS Dear Mr Pusey, Enclosed is the additional information that you had requested concerning the state stormwater permit application for Pender EMS If you have any questions or need any additional information, please feel free to contact me at 910-259-4800 or ruegerna,waltonen ing eering.net Thanks for your time Sincerely, J Rueger Houck Jr Environmental Scientist KECEIVED MAY 77 2010 Tel 910-2594800 PO Box 895, Burgaw, North Carolina, 28425 Fax 910-259-1779 VALTON ENGINEERIN May 25, 2010 Mr Steve Pusey NC DENR Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Re. Stormwater Permit Application, Pender EMS Dear Mr. Pusey, Enclosed is the letter authorizing Woodrow W Sullivan to sign for Pender Volunteer EMS & Rescue, Inc If you have any questions or need any additional information, please feel free to contact me at 910-259-4800 or ruegerna,waltonen ine eering net Thanks for your time! Sincerely, 01i . Rueger Houck Jr Environmental Scientist RECEIVED MAY 2 6 2010 BY: Tel 910-2594800 PO Box 895, Burgaw, North Carolina, 28425 Fax 910-259-1779 PENDER EMS VOLUNTEER EMS & RESCUE, INC. May 20, 2010 To Whom it May Concern: Headquarters 14388 Highway 210 West Rocky Point, NC 28457 Tel 910-675-9198 Fax 910-675-9169 www PenderEMS com Woodrow W Sullivan III. Director I hereby authorize Woodrow W. Sullivan as my agent to sign permit applications and related documents for Pender Volunteer EMS & Rescue, Inc. Sincerely, rBo rd of Directors President Pender Volunteer EMS & Rescue, Inc. Pusey, Steven From: J Rueger Houck [rueger@waltonenginee ring net] Sent: Thursday, May 20, 2010 8 37 AM To: Pusey, Steven Subject: Re Fender EMS Good Morning Mr. Pusey, You have my approval for the change. The only reason I had to change the calculations for swale #3 is that to include the vegetative filter strip, I had to increase the area of drainage area #3. 1 only had to increase it ever so slightly. The square footage increased but not enough to make the overall acreage increase. It remained at 2,23 Ac disturbed area Since I had originally based my Qfor swale #3 on the square footage of drainage area #3, 1 felt it necessary to re -calculate this value. It only increased the flow by a couple of hundredths but I felt it still needed to be done. There were no other changes to swale #3 except that one value. Hey lust checking on the 0&M signatures The last ones I submitted to you had Woody listed as Agent. I am currently trying to track down the president. I have been all over the Secretary of State website, but there is no president listed. I am going to make some calls today and hopefully I will have that letter to you tomorrow. Thanks again! ----- Onginal Message _ _ From: Pusey, Steven To: rueger(cDwaltonenoineenng net Sent: Wednesday, May 19, 2010 3 32 PM Subject: Fender EMS Rueger Your calculations look good but your Supplement shows SA/DA ratio of 3.8. It should be 5.1 as shown in your calculations. This will also change the required surface area 14,954 sf in your calculations) I will make the revisions by hand on your Supplement upon your approval Also, please explain why grassed swale #3 changed? Thanks, Ste Environmental Engineer NC DENR - Division of Water Quality Surface Water Protection - Stormwater Tel, (910) 796 7215 Fax (910) 350-2004 E-mail Stgvcn Puscy@ilncde rgcv E-mail correspondence to and from this address may be subject to the NC Public Records law and maybe disclosed to third parties WALTON ENGINEERIN May 17, 2010 Mr Steve Pusey NC DENR Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Re. Stormwater Permit Application, Pender EMS Dear Mr. Pusey, Enclosed is the additional information that you had requested concerning the state stormwater permit application for Pender EMS I checked the pond design to see if it would meet the design criteria for 90% TSS removal and it did. This removed the requirement of a properly sized level spreader and vegetative filter for the discharge from the wet pond for a 10 year storm I then sized an outlet protection consisting of class B rip rap according to the Erosion and Sedimentation Control Design Manual. I included Figure 8 06a from the manual showing the sizing calculations Additionally we left the 30' vegetative filter for added pollutant removal. Because we kept the 30' vegetative filter our disturbed area and drainage area #3 increased in size but not enough to change the total acreage I included page three from the state stormwater permit application showing the updated square footage for drainage area #3 I also included the spreadsheets for grass swale #3, the wet detention pond, the supplement for both, and Figures 1, 2, & 7 with the updated pond volumes and new outlet design. If you have any questions or need any additional information, please feel free to contact me at 910- 259-4800 or rueger waltonen ing eering net Thanks for your time MAY 19 2010 Sincerely, �Rueger Houck Jr. Environmental Scientist Tel 910-2594800 PO Box 895, Burgaw, North Carolina, 28425 Fax 910-259-1779 Pusey, Steven From: Pusey, Steven Sent: Wednesday, May 19, 2010 10 45 AM To: 'rueger@waltonengineering net' Subject: Remaining Additional Information Rueger As discussed, we are now waiting on revised plans showing a 90% wet detention pond, and revised Supplement and O&M Agreement for the wet detention pond In addition, the applicant, Woodrow W Sullivan, is listed as Chief on the permit but listed as the Agent on the Secretary of State's website Please advise whether Mr. Sullivan is the President, Vice -President, or is an authorized agent If he is an authorized agent, please submit a letter from the President authorizing Mr Sullivan to sign the permit We expect this information to be submitted by latest, May 28, 2010 Please advise if you have any questions Best regards, Steve'FarseY Environmental Engineer NC DENR - Division of Water Quality Surface Water Protection - Stormwater Tel: (910) 796.7215 Fax: (910) 350-2004 E-mail: Steven. Pusey(cbncdenr.gov E-mail correspondence to and from this address maybe subject to the NC Public Records Low and may be disclosed to third parties Appendices 30 Outlet N = Dot La pipe diameter (D0) La T ilwater 0.5Do l\,al�l�l 11P, � o'<PPt�6o .,rrll j ti K0.9r !ili I III N! �n���ti`v _50.}; ft�ii� III Iljl lilll� ..0 �-q 1, - - - u; f illi : Lhl.;i Emrammmmu lmmmmoamm s mmrmmeMMHm emmm I'll D - _1D 0 4 M 4 33 l I ' lvirto+W"npi oe ��•. .. III j : u I I!il1°ill I'I , I' =l'I'' ,i — - -- v-as-ril�-� : I I I'I i I^-�� � — �-�I�-•�-•I-i-I-•-� -,- - � - µi �-± l 0 tt 3 5 10 20 59 100 200 500 1000 Lf�� Discharge (ft31sec) c Curves may not be extrapolated Figure 6.06s Design of outlet protection protection from a round'p:pe flowing full, minimum tadwater condition (T., < 0.5 diameter) i MAY 1 8' 2010 Re\. 12/93 —�— 8.06.3 C WET POND DESIGN Project Name FENDER EMS Calculated By RUEGER Date 1/12/2010 Drainage Area, DA = 223 acres Impervious Area, Ai = 101 acres Percent Impervious, I = 453 % Average Depth, Havg = Vpp/App = 203 it Depth to Clean out (from veg shelf), Hbvs = 35 it below Bottom Veg Shelf Bottom Depth (at Clean Out), Hb = 40 it below Permanent Pool Average Depth Rounded to Nearest Value in SAIDA Chart = 30 Interpolation Values IMP% SAIDA @ Lower Value Lower Value Hi her Value 40 45 50 56 SAIDA (%) for 90 % TSS REMOVAL 30 FOOT VEGETATED FILTER REQUIRED AVG DEPTH ft 30 35 40 45 50 55 60 65 70 75 IMP% 10 13 10 08 07 06 05 04 03 02 01 20 24 20 18 17 15 14 12 10 09 06 30 35 30 27 25 22 19 16 13 11 08 40 45 40 35 31 28 25 21 18 14 11 50 56 50 43 39 35 31 27 23 19 15 60 70 60 53 48 43 39 34 29 24 19 70 81 70 60 55 50 45 39 34 29 23 80 94 80 70 64 57 52 46 40 34 28 90 107 90 79 72 65 59 52 46 39 33 101) 1 120 1 1001 88 1 81 73 1 66 i 58 51 43 36 Interpolated SAIDA @ Rounded Average Depth = 51 (linear interpolation) Min. Required Surface Area at Permanent Pool, App = 4,954 = SAIDA " DA' 435601100, s f Design Storm, Sd = 1 5 Inches Rv = 05 + 009(1) = 046 TP Volume Required, VIP = Sd x (1/12) x DA x Rv x 43,560 = 5,585 c f Surface Area Provided @ PP, App = 6,005 s f (determined by 2D CAD Analysis) Elev. @ PP, ELpp = 4000 feet Let Min. Temp Pool Depth Required, Hip Min = Vtp/App = 0 93 feet TP Depth Selected, Htp = 100 feet Elev @ TP, ELtp = Elpp + Hip = 41 00 feet Surface Area Provided @ TP, Atp = 8,467 s f (determined by 2D CAD Analysis) TP Volume Provided, Vtp = [(Alp + App)/2] x Hip = 7,236 c f TP Volume Provided > Required? Yes If "No", increase volume provided Surface Area @ PP Provided > Required? Yes If 'No", increase area provided Area at Top of VS, Atvs = 7875 s f (determined by 2D CAD Analysis) Area at Bottom of VS, Abvs =, 3857 s f (determined by 2D CAD Analysis) Area at Bottom of PP (at Clean Out), All = 1,695 s f (determined by 2D CAD Analysis) PP Volume Provided, Vpp = [Hbvs' (All + Abvs)/2]+[O 5'(Abvs+App)/2] = 12,182 c f Forebay Volume Required, Vfb Min = Vpp x 0 2 = 2.436 c f Forebay Depth, Hfb = 400 feet Forebay Depth from VS, Hfbvs = 350 feet Forebay Bottom Area (at Clean Out) , Afbg = 221 s,f (determined by 2D CAD Analysis) Forebay Veg Shelf Surface Area, Afbvs = 882 Forebay Surface Area, APo = 1,337 s f (determined by 20 CAD Analysis) y Volume Provided, Vfb = [Hfbvs' (Albfl + Afbvs)/21+[0 5'(Afbvs + APo)/2] = 2,485 c f Forebay Volume Provided > Required? Yes If "No", increase volume provided Orifice Sizing Flowrate 2 Day Drawdown = Vtp/(2 x 86,400) = 004 c f s 3 Day Drawdown = Vtp/(3 x 86,400) = 003 c f s 4 Day Drawdown = Vtp/(4 x 86,400) = 002 c f s 6 Day Drawdown = Vtp/(5 x 86,400) = 002 c f s Note The values in this chart are non -linear Use linear interpolation only on adjacent values aadsheet and programmed the equations (as wn) into the spreadsheet I also certify that calculations hereon were performed by me or or my direct supervision r 11603 MpV 19 2010 WALTON ENaNEERIN May 03, 2010 Mr Steve Pusey '-NC DENR Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Re Stormwater Permit Application, Pender EMS Dear Mr Pusey, Enclosed is the additional information that you had requested concerning the state stormwater permit application for Pender EMS With the addition of a third swale, I reworked the drainage areas, creating a third one I also included the disturbed area of the proposed driveway and not just the area of the construction entrance like I had done before With the redesign of the drainage areas, I re -submitted the swale supplements and the wet detention basin supplement If you have any questions or need any additional information, please feel free to contact meat 910-259-4800 or rueeer@waltonengineering net. Thanks for your time Sincerely J I"' Houck Jr Environmental Scientist RECEIVED MAY 1 1 2010 BY:_____ -- Tel 910-259A800 PO Box 895, Burgaw, North Carohna, 28425 Fax 910-259-1779 Runoff Calculations Project Pander EMS Date 4/26/2010 Basin No Drainage Area I D Drainage Area (Total, s f ) Drainage Area (Total, ac Drainage Area Breakdown Description Runoff Coefficient Pre -Development _ Design Storm ( r) 10 Post -Development Design Storm r) 10 1 1 2 3 1 1 2 3 96,987 28,721 26,581 41,685 223 Area (s f) 000 Area (s f) 000 Area Is f) 000 Area IS f) 066 Area Is f ) 061 Area (s f ) 096 Area (s f) 000 Area (s f ) Sidewalks 085 0 524 --73-6--y 1,858 Natural Vegetation 02 96,987 6,531 1 6,628 39,827 Building 085 0 4,906 10,395 0 Parking 085 0 16,760 8,822 0 Runoff Coefficient, Total Drainage Area Height of Most Remote Point Above Outlet (ft) Maximum Length of Travel (ft) To (min) Rainfall Intensity (in/hr) Peak Runoff(cfs) 0200 #DIV/01 #DIV/01 #DIV101 0 702 4 0 688 0 229 #DIV/01 5 1 59 / 1 59 i 5 286 240 170 135 2 8 3.7 2 7 1 3 912 912 912 912 406 #DIV/01 #DIV/01 #DIV/01 1 422 383 200 #DIV/01 RErl"'TWED MAY 1 1 2010 BY: m H (ft) r.nn Note Use nomograph Tc for natural basins with well-defined channels, for overland flow on bare earth, and for mowed -grass roadside channels 1; For overland flow, grassed surfaces, multiply Tc)l by 2 rl For overland flow, concrete or asphalt r For concrete channels, multiply Tc by Figure 8.03E Time of concentration of small crainage basins 8.03.4 Tc by 0 4 11 JrO Mai 3:1 V-Bottom Grassed Swale Design Project: PENDER EMS Design Storm (yr): 10 Swale. 1 Drainage Calculations Drainage Area (s f ), Drainage Area (acres). Runoff Coefficient Vertical Drop (ft): Max Length of Travel (ft) ime of Concentration (min ) Rainfall Intensity (in/hr) Runoff (ftA3/sec) Swale Data Vertical Drop (ft) Swale Length (ft) Average Slope (ft/ft)- Average Slope (%) Maximum Velocity (ff/sec). MAY 1 1 2010 Designed By: Rueger Houck Date- 1/19/2010 Asf = 28,721 A = 0.66 C = 0.702 Ha = 1.59 (H = height of most remote point above outlet) La = 240 Tc = 3.7 1 = 9.12 Qd = 4.26 h =M20 Retardance Class Ls = S = S= Vmax = Governing Functions: x = 6h (Wetted Swale Width, ft) (3:1 V-Swale ONLY') Pw = 6.32*h (Wetted Perimeter, ft) (3:1 V-Swale ONLY') Aw = 3*hA2 (Cross Sectional Wetted Area, ffA2)(3:1 V-Swale ONL' R = 0.47*h (Hydraulic Radius, ft)(3.1 V-Swale ONLY') Continuity Equation: Q = A*V (Volumetnc Flow, ftA3/sec) Manning's Formula: Vm = (1.49/n)*RA(2/3)*SA(1/2) (Velocity, ft/sec) Vd = Qd/Aw (Velocity, f /sec)(3.1 V-Swale ONLY!) Calculations Enter h and n Adjust until Qm >= Qd (get n from graph of V*R vs n) h =W705 ft x =ft Vm= 0 88 (Velocity from Manning's, fps Aw =ftA2 Qm = 5.9 (Flow from Manning's, cfs) R=ft Qd = 4 3 (Design Flow, cfs) Appendices 02 Step 10. For grass -lined channels once the appropriate channel dimensions have been selected for low retardance conditions, repeat steps 6 through 8 using a higher retardance class, corresponding to tall grass Adjust capacity of the channel by varying depth where site conditions permit. NOTE I If design velocity is greater than 2 0 f /sec , a temporary lining may be required to stabilize the channel until vegetation is established The temporary liner may be designed for peak flow from,the 2-year storm If a channel requires a temporary lining, the designer should analyze shear stresses in the channel to select the liner that provides protection and promotes establishment of vegetation For the design of temporary liners, use tractive force procedure NOTE 2 Design Tables —Vegetated Channels and Diversions at the end of this section may be used to design grass -lined channels with parabolic t cross -sections Step 11. Check outlet for carrying capacity and stability If discharge I velocities exceed allowable velocities for the receiving stream, an outlet protection structure will be required (Table 8 05d, page 8 05 9). Sample Problem 8 05a illustrates the design of a grass -lined channel ®nnnn_o_il MIME Le n1��V �111\1����IIIIn� ■■l���• go mom ®nnn�o:niinn�-:::::::: 6 8 10 2 4 6 8 10 20 .I VR, Product of Velocity and Hydraulic Radius f Figure 8.05c manning's nrelated torvebay• hydraulic radius, and vegetal retardance Note. From Sampe Problem 8 05a mulUpy VD x Hydmluhc Ramus (4 5xo 54=2 43), then enter the product of VR ano extend c straight line up to Relaroance cjws'0' next protect a straight line W the left to deler ial manning's n XCEIVED Ret. 12/93 4AY 8.05.7 3:1 V-Bottom Grassed Swale Desilrn Project: PENDER EMS Design Storm (yr): 10 Swale: 2 Drainage Calculations Drainage Area (s f.) Drainage Area (acres) Runoff Coefficient* Vertical Drop (ft) Max Length of Travel (ft) ime of Concentration (min ) Rainfall Intensity (in/hr). Runoff (ftA3/sec) Swale Data Vertical Drop (ft) Swale Length (ft) Average Slope (fUft): Average Slope (%), Maximum Velocity (ft/sec): Designed By Rueger Houck Date 1/19/2010 Asf = 26,581 A= 061 C = 0 688 Ha = 1 59 (H = height of most remote point above outlet) La = 170 Tc = 2.8 1 = 9.12 Qd =1 386 h = 1 Retardance Class: �D Ls = 26 S = 0 038 S= 385 Vmax Governing Functions: x = 6h (Wetted Swale Width, ft) (3:1 V-Swale ONLY!) Pw = 6 32*h (Wetted Perimeter, ft) (3:1 V-Swale ONLYI) Aw = 3*W2 (Cross Sectional Wetted Area, ftA2)(3.1 V-Swale ONL R = 0 47*h (Hydraulic Radius, ft)(3 1 V-Swale ONLY') Continuity Equation. Q = A*V (Volumetric Flow, ftA3/sec) Manning's Formula: Vm = (1 49/n)*RA(2/3)*SA(1/2) (Velocity, ft/sec) Vd = Qd/Aw (Velocity, ft/sec)(3:1 V-Swale ONLYi) Calculations Enter h and n Adjust until Qm >= Qd (get n from graph of V*R vs n) h= 1 ft x = 6 ft Vm= 2.45 (Velocity from Manning's, fps Aw = 3 ftA2 Qm = 74 (Flow from Manning's, cfs) R= 047 ft Qd = 3.9 (Design Flow, cfs) V*R= 0.60 n= 0.072 RECEIVED MAY 1 1 2010 Y: Appendices 04 02 Step 10. For grass -lined channels once the appropriate channel dimensions have been selected for low retardance conditions, repeat steps 6 through 8 using a higher retardance class, corresponding to tall grass Adjust capacity of the channel by varying depth where site conditions permit. NOTE I If design velocity is greater than 2 0 ft/sec , a temporary lining may be required to stabilize the channel until vegetation is established The temporary liner may be designed for peak flow from the 2-year storm If a channel requires a temporary lining, the designer should analyze shear stresses in the channel to select the liner that provides protection and promotes establishment of vegetation For the design of temporary liners, use tractive force procedure NOTE 2 Design Tables —Vegetated Channels and Diversions at the end of this section may be used to design grass -lined channels with parabolic cross -sections Step 11. -Check outlet for carrying capacity and stability. If discharge velocities exceed allowable velocities for the receiving stream, an outlet protectior�strucmre will be required (Table 8 05d, page 8 05 9). 1, Sample Problem 8 05a illustrates the design of a grass -lined channel ■■■l M== 0 ����■\1441 �. Less than 2" how moil ON own on ism, L10■N�� ����iiii�� 2 4 1,v 8 10 2 4 6 8 10 20 VR, Product of Yf Velocity and Hydraulic Radius I Figure 8.05c Manning's n related to vebraty, hydraulic radius, and vegetal re rda nw Note: From Samole Problem 8 05a mulCply Vo x Hydralulic Radius t4 5x0 54_2 43 - of VR ano extend e straight line uo to Retaraance dass -0-,next rojecta straight Ime n RE)h ing's r, MAY 112010 Rei. 12/93 i] �-; 8.05.7 3:1 V-Bottom Grassed Swale Design Project: FENDER EMS Design Storm (yr) 10 Swale. 3 Drainage Calculations Drainage Area (s f.) Drainage Area (acres) Runoff Coefficient Vertical Drop (ft) Max. Length of Travel (ft) ime of Concentration (min.) Rainfall Intensity (in/hr) Runoff (ftA3/sec). Swale Data Vertical Drop (ft) Swale Length (ft): Average Slope (ft/ft), Average Slope (%): Maximum Velocity (ft/sec): Designed By Rueger Houck Date 1/1912010 Asf= 41,939 A = 0.96 C = 0.229 Ha = 5 (H = height of most remote point above outlet) La = 135 Tc = 1 3 i = 9.12 Qd =1 2.03 h = 0.5 Retardance Class Ls = 155 S = 0 003 S= 032 Vmax = 2.0 Governing Functions: x = 6h (Wetted Swale Width, ft) (3:1 V-Swale ONLY[) Pw = 6 32*h (Wetted Perimeter, ft) (3-1 V-Swale ONLY') Aw = 3*hA2 (Cross Sectional Wetted Area, ftA2)(3 1 V-Swale ONL' R = 0 47*h (Hydraulic Radius, ft)(3 1 V-Swale ONLYI) Continuity Equation, Q = A*V (Volumetric Flow, ftA3/sec) Manning's Formula, Vm = (1.49/n)*RA(2/3)*SA(1/2) (Velocity, ft/sec) Vd = Qd/Aw (Velocity, ft/sec)(3:1 V-Swale ONLY') Calculations Enter h and n. Adjust until Qm >= Qd (get n from graph of V*R vs n) h = x= Aw = R= V*R= n= 1.5 It It ftA2 ft 9 675 0 705 021 013 Vm= 0 52 Qm =1 3.5 Qd = 2-0 (Velocity from Manning's, fpE (Flow from Manning's, cfs) (Design Flow, cfs) RC:10010 A i� — Appendices 5 04 02 Step 10. For grass -lined channels once the appropriate channel dimensions have been selected for low retardance conditions, repeat steps 6 through 8 using a higher retardance class, corresponding to tall grass Adjust capacity of the channel by varying depth where site conditions permit NOTE 1 If design velocity is greater than 2.0 fl/sec., a temporary lining may be required to stabilize the channel until vegetation is established The temporary liner may be designed for peak flow from the 2-year stone If a channel requires a temporary lining, the designer should analyze shear stresses in the channel to select the liner that provides protection and promotes establishment of vegetation. For the design of temporary liners, use tractive force procedure NOTE 2 Design Tables —Vegetated Channels and Diversions at the end of this section may be used to design grass -lined channels with parabolic cross -sections Step 11. Check outlet for carrying capacity and stability If discharge velocities exceed allowable velocities for the receiving stream, an outlet protection structure will be required (Table 8 05d, page 8 05.9). Sample Problem 8.05a illustrates the design of a grass -lined channel 1'1UL-1 K,_ I MAY 11201z NM 116411►�i� 1 o 2 o than 2" = � noLess MEN���I��®���iiii�� v b e 10 2 i VR, Product of Velocity and Hydr Figure 8 05c Manning's n related to velocity, hydraulic radius, and vegetal retardance Note: From Sample Problem 8 05a mulnoly Vo x Hvdralulr Radius (4 5x0 54=2 43), I straight line up to Retaraance cass -0', next oroiect a straight line ro Ine left m 4 6 8 10 20 Radius the product of VP, ano extend z a teal mammng's r, Rer 12/93 ti 8.05.7 +ZWKWA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director April 23, 2010 Woodrow W Sulllivan Pender Volunteer EMS & Rescue, Inc 14388 NC Hwy 210 Rocky Point, NC 28457 Subject: Request for Additional Information Stormwater Project No. SW8 100315 Pender EMS Pender County Dear Mr Sullivan Dee Freeman Secretary The Wilmington Regional Office received and accepted a State Stormwater Management Permit Application for Pender EMS on March 16, 2010 A preliminary in-depth review of that information has determined that the application is not complete The following information is needed to continue the stormwater review Please specify BMP and swale side slope vegetation and the wetland species to be planted on the 10 1 vegetated shelf of a wet pond A soils report for all engineered systems and curb outlet swale systems is required The report should contain the estimated Seasonal High Water Table (SHWT) elevation at each proposed BMP location reported in FMSL, not as a depth below existing ground (BEG) If it's reported as a depth BEG, the bore map must include the existing ground elevation at each bore location Please show the SHWT elevation on the sectional drawing of the pond. 3 Please ensure that swale bottom elevations have an average of 1' separation from the SHWT Show swale spot elevations on the drawing 4 Please revise page 3 of the application, data table, showing values for existing BUA which should be 0. 5 Please add the following information to the elevation / area table on the plans 0 Sediment cleanout elevation / area 0 Bottom of vegetated shelf elev. / area 0 Top of vegetated shelf elev / area 0 10-year storm elev / area 6 Please show all elevations listed in item 5 above on the sectional drawing of the pond 7. Please show a detail of the level spreader on the details page Note that width of level spreader should be designed in accordance with the BMP manual for the flow rate of the 10-year storm Wilmington Regional Office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 One Phone 910-796-7215 1 FAX 910-350-20041Customer Sennoe 1-877-623-6748 NorthCarolina Internet v rimaterquality org a'�atma//y 'An Equal Oppodunity l Affirmative Action Employer (/ {v !4L " Pender Volunteer EMS & Rescue April 23, 2010 Stormwater Application No. SW8 100315 8 Please correct the legend for the proposed contours and show all proposed contours on the site map 9 Please show a swale to direct the runoff from the helipad into the forebay of the pond, and account for this BUA in the calculations Also, please submit a swale calculation sheet for this item. 10 The applicant, Woodrow W Sullivan, is listed as Chief on the permit but listed as the Agent on the Secretary of State's website Please advise whether Mr. Sullivan is the President, Vice -President, or is an authorized agent If he is an authorized agent, please submit a letter from the President authorizing Mr Sullivan to sign the permit 11. Please remember that a change to one number may have a domino effect on other numbers Please check all plans, calculations and forms and make changes as needed Please note that this request for additional information is in response to a preliminary review The requested information should be received in this Office prior to May 20, 2010, or the application will be returned as incomplete The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to submit the information, please mail, email or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter The request must indicate the date by which you expect to submit the required information The Division is allowed 90 days from the receipt of a completed application to issue the permit The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215 1 and is subject to enforcement action pursuant to NCGS 143-215 6A Please reference the State assigned protect number on all correspondence Any original documents that need to be revised have been sent to the engineer or agent All original documents must be returned or new originals must be provided Copies are not acceptable If you have any questions concerning this matter please feel free to call me at (910) 796-7215 or email me at steven pusey@ncdenr gov Sincerely, Steve G. Pusey Environmental Engineer GDS/sgp- S.\WQS\STORMWATER\ADDINFO\2010\100315 apr10 cc. Mark Walton, PE — Walton Engineering Steve Pusey Wilmington Regional Office Stormwater File Page 2 of 2 v .vJc" Vaoa¢c. S I oermvm: V,21gn6on Date: Project Received Date Acce fed elected, car le one Project Location dd egwred (e no Date received S mbols foi comoleLna form '✓'= Yas/r)K 'X'= Nn/rlafiriaN 'n/.' Rule(s) Subject (check all that apply)• ❑ 1995 Coastal 1?'2008 Coastal ❑ Phase II ❑ Universal Paperwork. check for $505 (must be no older than 6 months) �Q�Appllcatlon form with correct/onglnal signatures (original plus 1 copy) If Corporation or LLC also o Print the info from the NCSOS o Either, 1 ) The applicant is listed on the NCSOS with his/her correct title or, 2 ) A notarized letter of authorization has been provided y\` supplements (1 original per BMP) BMP type(s) POP,3p (2DR.5 -b NDi (WS /U 1 To L$(FS &M with correct/onginal signatures (1 original per BMP, except level spreaders/filter strips and swales) Deed restrictions (if outparcel or subdividing) (original plus 1 copy) o Deed restriction template (signed and notarized) or o Proposed Declaration of Covenants and Restrictions (signed and notarized) oils report identifying the SHWT supporting calculations, signed & sealed (if necessary) &--I�eceiving stream classification C,•,SL J , If SA or ORW also o SA USGS topo map with the site, the receiving waters and the mile radius shown to scale o ORW 575 ft of MHWL for Area of Environmental Concern and max BUA per rule ,jal-`Modifications 1 ) If built Designer's Cert , 2 ) If partially built Partial Cert , 3 ) If not built No Cart needed Development Type (check all that apply): El Residential or !!'Commercial Q Deed restrictions match? ❑ Subdivision or lKingle Lot ❑ Deed restrictions match? 111" High Density or Q Low Density Q Deed restrictions match? NIR ❑ Offsrte project ❑ Redevelopment Q Modification ® Exempt r�IR ❑ NCG02 (bulkhead) Cl NCG03 (clear/glade) ❑ NCG04 (linear) Density. Q,' BUA calculations include common areas, clubhouse, sidewalks, etc CV BUA % a1. (p , Matches high/low density requirement for rule and receiving stream class L/ No obvious math errors If High Density Design storm correct for rule and receiving stream class %.,a r Plans, si ned and sealed (2 sets): wo sets received dr-IlLaiyout (with proposed BUA dimensions) 9Gr�ading Q- DJainage area map (all HD systems & curb outlet swales) Cindy map Cy/Project Boundaries CjCegend Wetlands o Delineated on plans o,- "No wetlands onsite" on plans Q..-Details o Roads o Cul-de-sacs o Curbing o Sidewalk o BMPs/ Level spreaders/ Filter strips/ Curb outlet swales o Buildings (Apts or Condos) OffusKe Projects: ® D Igner's Certification has been submitted for the Offslte BMP receiving the runoff from the project ❑ eed restrictions have been recorded and a copy submitted for the Offsite BMP permit Lot size has not changed from what was approved under the Master Plan ❑ Correct lot nurnbei is referenced on the suppiernent roim ® site system Is in compliance with its permit, if known Ittfrltr n Projects: ❑ Soils report SHWT, soil type, and expected infiltration rate are provided ❑ DWQ has conducted a site visit? Date Wet Ponds. Permanent Pool Meets One of the Followmg: ❑ Is located no lower than 6" below the estimated SHWT ❑ Incoming groundwater is quantified and evaluated, AND Storage volume verified, AND Outlet evaluated for free drainage to the receiving waters under SHWT conddlons Decision (check one): LJ Complete Return file to admen (Jo Casmer) to login (Stamped in received date = BIMS date) El Slightly incomplete E-mail consultant, request information to ba returned wiihrn one business day (24 houis after request Info requests on Friday, allow a return on the following business day) If into not returned, Issue- an application return letter and give everything to admen (Add info received date = BIMS date) ❑ Substantially incomplete Issue an application return letter and give everything to admen WALTON ENCINEERIN Certification I hereby certify that the calculations submitted with the Stormwater Management Application for Pender EMS were performed under my direct supervision I hereby certify that I personally developed and tested all spreadsheets submitted with the plans and applications for Pender EMS and that each spreadsheet uses correct formulas and equations P E. Signature P E Name :'I SEAT. Registration No 16879 16879 State: North Carolina Date: 3/11 / Ib Tel 910-2594800 PO Box 895, Burgaw, North Carolma, 28425 Fax 910-259-1779 +P0194o°;�;tt. P+Mer e+u+t - c+w rorz PIN 0 3da1-(a5--AS-3- 00o 8ld-p9 -jNr Exose Tax "00 (Tat En pt N C G S § 105-228 28) �a1J14 m cr 3229-65-3953-0000 STATE OF NORTH CAROLINA PENDER COUNTY GENERAL WARRANTY DEED Tlus General Warranty Deed is made and entered into this the I 1 a' day of August, 2o09, by and between the Town of Burgaw, a North Carolina municipal corporation organved and existing under the laws of the State of North Carolina ("Grantor") and Pender Volunteer EMS and Rescue, Inc, a North Carolina non-profit corporation, (hereinafter referred to as "Grantee"), WITNESSETH: That the Grantor, for valuable consideration paid by the Grantee, the receipt of which is hereby acknowledged, has and by these presents does grant, bargain, sell and convey unto the Grantee rn fee simple that certain tract of real property located in the Town of Burgaw, Burgaw Township, Pender County, State of North Carolina being fully described as follows, to wn, located in the Town of Burgaw, Burgaw Township, Pender County, North Carolina and being more fully described as follows, to wrt• Being all of Tract 2A and consisting of approximately 3.406 acres, more or less, as shown on a survey map entitled "Map of Division for Park Lake Properties, LLC" as prepared by Daniel H Thompson, PLS from a survey on February 4, 2008, and recorded in Map Book 48, at Page 68 in the Office of the PenderCountyRegister of Deeds, State of North: CaF6tina; remf:rence to which is hereby made for a morecomplete and accurate description To have and to hold the aforesaid tract or parcel of land and all privileges and appurtenances there unto be ngurg to the Grantee and its successors and assigns. tleore 8 Xen+n MAR 16 2010 �366�.P6195p,o a::tno pmd�r Ceuntya epbbr or 0eide pay* 3 of 2 And Grantor does covenant that it is seized of said premises in fee simple and has the right to convey the same in fee simple, that the same is free from encumbrances, and that it will warrant and defend the said title to the same against all claims of all persons whatsoever except for the exceptions hereinafter stated Title to the property hereinabove described is subject to the following exceptions - Town of Burgaw and Pender County real property taxes for the year 2009 and subsequent years, if assessed. 2. All utility and roadway easements of record in the Office of the Pender County Register of Deeds, State of North Carolina Zoning and subdivision ordinances of the Town of Burgaw adopted and in effect as of August 11, 2009 In Testimony Whereof, said Grantor has caused this instrument to be signed in its corporate name by the authority of its Mayor on the day and year first above written TOWN OF BURGAW By Kenneth T Cowan, Mayor Attested to� _C l.�nr,c'i To Clerw� k -- STATE OF NORTH CAROLINA COUNTY OF PENDER 1. R-nra+ c— Ke.iw.r :ZL. , a Notary Public for the aforesaid County and State, certify that Sylvia W. Raynor personally came before me this day and acknowledged that she is Clerk to the Board of Commissioners of the Town of Burgaw, a North Carolina municipal corporation and that by authority duly given and as the act of the Town of Burgaw, the foregoing instrument was signed in its name byits Mayor; Kenneth-T: Cowan; sealed with its corporate — seal, and attested by herself as its Clerk. Wr s my hand and official seal, this the 1I" day of August, 2009. c ROBERT C. KENAN. JR. NQMRKF21tt8Bn1;) My Commission Expires `-$ .der3 PENDER COUNTY, NO Needham Environmental Inc. Robes N Needham, PWS 9100 Chuleslowoc Rd SE Wmnabow, NC 28479 Office/Fax (910)371-6082 needhambud(&ec u com Rueger Houck Walton Engineering P.O. Box 895 Burgaw, NC 28425 Tom Gulley, NCLSSH1256 P O_ Box 960 Wilmmglon, NC 28402 Office/Fax (910)795-0319 lgullcycgmail com December 31.2009 RE: Seasonal High Water Table and Infiltration Rate Detemmnation for Pender County EMS Site, Burgaw, North Carolina. Dear Rueger: On December 30, 2009, I performed a stormwater evaluation for the above -mentioned tract, located off Ridgeway Road. Two soil bonngs were placed at locations predetermined by your office. Labeled, pin flags were placed at each boring location. Attached are detailed soil profile descriptions with estimated infiltration rates and estimated seasonal high water tables. If you have any questions or concerns, please contact me at (910)297-1282, (910)795-0319, or by e-mail at tnulley(cilglnail.com. MAR ` 6 zoo Sincerely, J. Tom Gulley, Jr. North Carolina Soil Scientist # 1256 Pender EMS - Ridgeway Road Soil Profile Descriptions Infiltration Location Horizon Depth Color Texture Structure Rate (in/hr) X7 A 0-5" 2.5Y 2 5/1 Fine Sandy Loam Weak Granular 1-2 E 5-14" 2 5Y 613 Loamy Fine Sand Weak Granular 2-3 Bit 14-26" 2.5Y 6/6 Fine Sandy Loam+ 1 W eak SBK 1-1.5 Bt2 26-42"+ 2.5Y 6/6 FSandy Clay Loam 2Weak SBK 0 5-1 Notes/Mottles observed water = 40" estimated water table = 26" w/ cfd 2 5Y 6/2, 2.5Y 6/3, & 10YR 6/8 mottles w/ mcp 2.5Y 7/1 & 10YR 6/8 mottles X1 A 0-8" 2.5Y 4/3 Loamy Fine Sand Weak Granular 1-2 observed water = >36" E 8-15" 2 5Y 6/4 Fine Sandy Loam Weak Granular 2-3 estimated water table = 24" Bt1 15-21" 2 5Y 6/6 FSandy Clay Loam Weak SBK 1-1.5 w/ fff 2.5Y 6/4 & 2.5Y 6/8 mottles Bt2 21-24" 2 5Y 6/8 FSandy Clay Loam 3Weak SBK 0 5-1 w/ fff 2.5Y 613 & 2.5Y 6/8 mottles Bl3 24-36"+ _2.5Y 6/8 FSandy Clay Loam Massive 0 1-0 5 w/ mmd 2 5Y 6/2 & 7 5YR 6/8 mottl RECEIVED MAR 16 2010 BY: Needham Environmental, Inc. O� p e n C> OVINERSHI P 03122009 TOM OF BURGAW a`o I-t I / FINANCE OFFICER BURGAW, NC 28425 DEED:3548 198 11212008 397000 RECEIVED MAR 16 2010 BY: B #ISTRUCTUREISKTCH-SF*STHT= PRIOR VALUE LAND BL DG PROPERTY DESCRIPTION I TAX SUBDIVISIONS (PIN CARD NO I TR 2A P11 48J68 PARK LAKE DI ITV1P BURGAW I3229-65-3953-0000 ITOWV OF BURGAW IRECORD NUMBER: k64 ENDER EMS IROUTE 6500,0 [LISTER: RI DGEVAOOD AVE I REVI EW ITOPQ ISTREET (UTILITY ZONING 3,41 ACRES (LEVEL IEXCELLENIELECTRIC RA NOTES: #ILAIND CLASS I SIZE IBASERATE*FRNT*DPTH*ADJ=ADJRATE*UNITS=LND-VALUE 12I53RWOOD LANI 3,41ACI 60001 0,95ACFI I 76001 3.411 25916 LAND! VALUE; #IOTHER FEAT I SIZE IBASERATE*COND OTHER VALUE: FNDATION IXTRFNI5HIROOF TYPE ROOF MTRL 5IZEIQTY VALLFNSHI FLOORS HEAT&AI R HEATFUEL I CONDI TI ON AD]: AREA RATE*GRDF+HEAT+EXVAL*VL HT-ADJRAT* AREA= 25916 =ADJRATE*UNITS=RCNOB-VAL RCN: RCNL D: MAP: 00480068 M RPCN* DEPF*CNDF=STR-VALUE STRUCTURE VALUE: APPRAISED -VALUE: 25916 WALTON ENGINEERING March 16, 2010 Ms Linda Lewis NC DENR Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Re Stormwater Permit Application, Pender EMS Dear Ms. Lewis, Enclosed is the Stormwater Site Plan This letter serves as the narrative description for the project for the Stormwater Management Permit Application The application is for a high -density project (with no curb or gutter), draining to C,Sw waters The application is for a new site to be developed The subject sit has established vegetation Currently there are no impervious areas on -site Stormwater runoff from the area will drain via two grassed swales into a wet detention pond Ultimately, stormwater runoff will flow into the Northest Cape Fear River Silt fencing will be used within the project area Routine inspections and maintenance will be performed to insure that the erosion control measures are in good condition and operating properly. Repairs will be made immediately to any erosion control measures found to be insufficient RT'CETVED MAR ' 6 2010 BY.--_---- Sincerely, CJ Rueger Houck J Environmental Scientist Tel 910-2594800 PO Box 895, Burgaw, North Carolina, 28425 Fax 910-259-1779 SOSID: 644764 Date Filed: 9/9/2002 11:09 AM 22 246 5294 STATE OF NORTH CAROLINA Elaine F. Marshall DEPARTMENT OF THE SECRETARY OF STA" North Carolina Secretary of State ARTICLES OF INCORPORATIOI NONPROFIT CORPORATION Pursuant to Section 55A-2-02 of the General Statues of North Carolina, the undersigned corporation does hereby submit these Articles of Incorporation for the purpose of forming a nonprofit corporation. I . The name of the Corporation is: Pender Volunteer EMS and Rescue. Inc 2. x (Check only if applicable.) The corporation is a charitable or religious corporation as defined in N.C.G.S. Section 55A-1-40(4). 3. The street address and county of the initial registered office of the corporation is: Number and Street 16660 US Highway 17 City, State, Zip Code Hampstead, NC 28443 County Pender 4. The mailing address if diJferentfrom the street address of the initial registered office of the corporation is: (Same) 5. The name of the initial registered agent is: Woodrow W. Sullivan III 6. The name and address of each incorporator is as follows: Charles David Morison, P. O. Box 1184, Hampstead, NC 28443 7. (Check either a or b): x a. The Corporation will have members. b. The Corporation will not have members. 8. Attached are provisions regarding the distribution of the corporation's assets upon its dissolution. 9. Any other provisions which the corporation elects to include are attached. 10. The street address and county of the principal office of the corporation is: 16660 US Highway 17, Hampstead, NC 28443 County Pender 11. The mailing address if different from the street address of the principal office is: (Same) 12. These articles will be effective upon filing, unless a later time and/or date is specified: This theAday of O , 2W2, Signature ofSignature ofIncorporatorr Charles David Morison Type or print Incorporator's name an&litte ifany NOTES: I. Filing fee is $50.00. This document and one exactor conformed copy of these articles must be filed with the Secretary of State. (Revised July 1994) CORPORATIONS DIVISION 300 N. SALISBURY STREET RALEIGH, NC 27603-5909 Purposes of Corporation This corporation is organized for the following purposes(s): _ religious, x charitable, x educational, testing for public safety, scientific, _ literary, _ fostering national or international amateur sports competition, and/or _ prevention of cruelty to children or animals, including, for such purposes, the making of distributions to organizations that qualify as exempt organizations under Sections 501 (c)(3) and 170 (c)(2) of the Internal Revenue Code of 1986 (herein the "Code")(or the corresponding provisions of any future United States Internal Revenue Code). Prohibited Activities No part of the net earnings of the corporation shall inure to the benefit of, or be distributable to its members, directors, officers, or other private persons, except that the corporation shall be authorized and empowered to pay reasonable compensation for services rendered and to make payments and distributions in furtherance of the purposes set forth in these articles of incorporation. No substantial part of the activities of the corporation shall be the carrying of propaganda, or otherwise attempting to influence legislation, and the corporation shall not participate in or intervene in (including the publishing or distribution of statements) any political campaign on behalf of or in opposition to any candidate for public office. Notwithstanding any other provision of these articles, the corporation shall not carry on any other activities not permitted to be carried on (a) by a corporation exempt from Federal income tax under section 501 (c)(3) of the Code or (b) by a corporation, contributions to which are deductible under section 170(c)(2)) of the Code. Distributions upon Dissolution Upon the dissolution of the corporation, the Board of Directors shall, after paying or making provision for the payment of all of the liabilities of the corporation, dispose of all of the assets of the corporation exclusively for the purposes of the corporation in such manner, or to such organization or organizations organized and operated exclusively for charitable, educational, religious, or scientific or literary purposes as shall at the time qualify as an exempt organization or organizations under section 501 (c)(3) of the Code as the Board of Directors shall determine, or to federal, state, or local governments to used exclusively for public purposes. Any such assets not so disposed of shall be disposed of by the Superior Court of the county in which the principal office of the corporation is then located, exclusively for such purposes or to such organization or organizations, such as the Court shall determine, which are organized and operated exclusively for such purposes, or to such governments for such purposes. Where possible such assets shall be disposed of to agencies providing rescue and emergency medical services in Pender County, North Carolina. i t 1UL�(i�e�YA j t ... ... I:na twa u1 n..s: wcas auction of USGS aw Quadrangle Burgaw, NC Series (Topographic) Site Location Ma Pender County EMS Ridgewood Avenue Burgaw, NC 28425 Total Site Area = 3.41 Project Area -3.41 Disturbed Area -2.2.22 as E C turbetl Area Map �.,�ou�rvEMs Total Site Ana - 3.41 Project Area -3.41 Disturbed Area -2-22 S,te M.0 Total Ske Area - 3,41 Project Area -3.41 Disturbed Area -2.22 p 5 1, - I I Details I I f '/r' ; Con ;IS Parcels PENDER VOLUNTEER EMERGENCY PIN: 3229-65-3953-0000 Sale Price:Name: MEDICAL SERVICES & RESCUE INC Deed: 3668/194 Geed 8/12/2009 Date: Plat: 00480069 Address: PO BOX 650 City: ROCKY POINT State: NC Zip:28457 Land 25916 Value: Building Value: 0 Deferred Value: 0 Total 25916 Value: Subdivision: Neighborhood: 00 Tax G01 C52 R40 Codes: Zone: Incorp Property Address: RIDGEWOOD AVE Acres: 3.41 Township: BURGAW Property TR 2A PB 48/68 PARK LAKE DIV Description: 1:6a9 feet Pender County GIS pI�NDFP :, RECEIVfffj BY I of 1 12/l/2009 9:16 AN