HomeMy WebLinkAboutSW8070817_HISTORICAL FILE_20170524STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO SW8 010 81-1 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 20 n ri 5 2.4 YYYYMMDD Energy Mineral & Land Resources ENVIRONMENTAL QUALITY May 24 2017 ROY COOPER Governor MICHAEL S REGAN Secretary TRACY DAVIS Director Charles C Poindexter, 11, Manger Robert Huth, Manager Pelican Point CB LLC Developer I IDl Holdings, LLC, Property Owner 7923 Reunion Rd 5929 Market St Wilmington, NC 28411 Wilmington, NC 28405-3615 Subject State Stormwater Management Permit No SW8 070817 Pelican Point High Density CONPECH Stormfilter Project New HdnONer Count Dear Mr Poindexter and Mr Huth The Wilmington Regional Office received a complete modified State Stormwater Management Permit Application for Pelican Point on May 22, 2017 Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H 1000 We are forwarding modified Permit No SW8 070817 dated May 24, 2017, for the construction, operation and maintenance of the BMP's and built -upon area associated with the subject project This permit shall be effective from the date of issuance until October 12, 2021, and shall be subject to the conditions and limitations as specified therein Please pay special attention to the conditions listed in this permit regarding the Operation and Maintenance of the BMP(s), recordation of deed restrictions, certification of the BMP's procedures for changing ownership, transferring the permit, and renewing the permit Failure to establish an adequate system for operation and maintenance of the stormwater management system, to record deed restrictions, to certify the BMP's, to transfer the permit or to renew the permit, will result m future compliance problems As the identified developer of the project, Pelican Point CB LLC, shall be the designated permit holder and responsible for meeting the conditions and limitations specified therein The following modifications are included and covered by this permit 1 A revised site layout resulting in no net increase in the amount of built -upon area 2 The stormwater control measure (SCM) has been re -designed to be a Contech Stormfilter The overall size of the SCM has not increased Please be aware that it is the responsibility of the permit holders, Pelican Point CB, LLC and HDI Holdings, LLC, to notify the Division of any changes in responsibility for complying with the permit and request an ownership/name change for the stormwater permit However, please be reminded that if the development agreement between Pelican Point CB, LLC and I-IDI Holdings, LLC is dissolved, cancelled or defaults, and the Division is not notified by Pelican Point CB, LLC to transfer the permit, then the responsibility for permit compliance reverts back to the property owner, HDI Holdings, LLC fhe Division must be notified immediately of any permit ownership changes and submit a completed Name/Ownership form to the Division within 30 days Otherwise Pelican Point CB, LLC and HDI Holdings, LLC will be operating a stormwater treatment facility without a valid permit This is a %iolation of NC General Statue 143-215 1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $25,000 per day Stale of Nonh Carolina I En,nonmental Quallq I Energy Mineral and Land Rtsources Wilmington RLgional O(net 1127 Cardinal Drive Extension I wdminglon NC 28405 910 796 7215 State Stormxxater Permit No SW8 070817 Page 2 of 2 If any parts, requirements, or limitations contained m this permit arc unacceptable, you have the right to request an adjudicatory hearing by filing a written petition with the Office of Administrative Hearings (OAl1) The written petition must conform to Chapter 150B of the North Carolina General Statutes, and must be filed with the OAH within thirty (30) days of receipt of this permit You should contact the OAH with all questions regarding the filing fee (if a filing fee is required) and/or the details of the ffhng process at 6714 Mail Service Center, Raleigh NC 27699-6714 or x to telephone at 919-431-3000, or visit their website at www NCOAH corn Unless such demands are made this permit shall be final and binding If you have any questions, or need additional information concerning this matter please contact Christine Hall in the Wilmington Regional Office at (910) 796-7215 Sinccrely Lt �y Davis Al , Director Division of Energy Mineral and Land Resources GDS/cash \\\Stormwater\Permits & Prolects\2007\070817 HD\2017 05 permit 070817 cc Ho«ard Resnik, CSD Engineering New Hanoxer Countv Building Inspections Nea Hanoxer County Engineering Brian Stanberry, Town of Carolina Beach Din ision of Coastal Management Wilmington Regional Office Storm"ater File State of North Carolina I Environmcntal Qualitj I Energy Mmcial and Land Resources Wiimmgton Regional Office 1127 CardinalOrne Extension I Wilmington NC 28405 910 796 7215 State Stormwater Management Systems Permit No SW8 070817 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY, MINERAL AND LAND RESOURCES STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Pelican Point CB, LLC and HDI Holdings, LLC Pelican Point 402 N Lake Park Blvd, Carolina Beach, New Hanover County 17e]Gi1.lq construction, operation and maintenance of one (1) Contech Stormfilter in compliance with the provisions of 15A NCAC 2H 1000 effective January 1, 1995(hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Energy, Mineral and Land Resources (hereafter referred to as the Division or DEMLR) and considered a part of this permit This permit shall be effective from the date of issuance until October 12, 2021, and shall be subject to the following specified conditions and limitations I DESIGN STANDARDS This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data This stormwater system has been approved for the management of stormwater runoff as described in Section 15 of this permit The runoff from all built -upon area within the permitted drainage area of this project must be directed into the permitted stormwater control measure The stormwater control has been designed to handle the runoff from 24,364 square feet of impervious area The maximum built -upon area allowed for the entire project is 24,364 square feet 4 The drainage area will be limited to the amount of built -upon area indicated in Sections 12 and 15 of this permit, and per approved plans The built -upon area available for future development is limited to 1,000 square feet Page 1 of 7 State Stormwater Management Systems Permit No SW8 070817 The following design criteria have been provided in the CONTECH Stormfilter and must be and maintained at the design condition a Drainage Area acres Onsite, ft' Offsite, ft2 056 24,513 0 b Total Impervious Surfaces, ft2 Onsite ft2 Offsite ft' 24,364 24,364 0 c Design Storm inches 1 0 d Water Quality Volume, ft' 1,911 e Adjusted Water Quality Volume, ft3 1,433 f Permitted Storage Volume W 1,477 g Detention System Pipe Diameter ft Pipe Length, ft 2 470 h TSS Removal Efficiency % 85% i Event Mean Concentration, m /L 70 Cartridge Height 18 k Number of Cartridges 11 1 Bottom Elevation, FMSL 300 m Seasonal High Water Table, FMSL 278 n Bypass Weir Elevation, FMSL 500 o Time to Draw Down, hours 6 96 p Max Treatment Flow Rate, cfs 0 02 q Receiving Stream/River Basin Carolina Beach Yacht Basin / Cape Fear r Stream Index Number 18-87-31 2 s Classification of Water Body SB II SCHEDULE OF COMPLIANCE 1 No person or entity, Including the permittee, shall alter any component of the approved stormwater system shown on the approved plans unless and until the Division has approved of the revised plan 2 The stormwater management system shall be constructed in Its entirety, vegetated and operational for Its Intended use prior to the construction of any built -upon surface 3 During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately If the stormwater system is used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility 4 The permittee shall at all times provide the operation and maintenance necessary to assure that all components of the permitted stormwater system function at design condition The approved Operation and Maintenance Agreement is incorporated by reference into this permit and must be followed in its entirety and maintenance must occur at the scheduled intervals 5 Records of maintenance activities must be kept and made available upon request to authorized personnel of DENR The records will indicate the date, activity, name of person performing the work and what actions were taken Page 2 of 7 State Stormwater Management Systems Permit No SW8 070817 It is the responsibility of the permit holders, Pelican Point CB, LLC and HDI Holdings, LLC, to notify the Division of any changes in responsibility for complying with the permit and request an ownership/name change for the stormwater permit However, please be reminded that if the development agreement between Pelican Point CB LLC and HDI Holdings, LLC is dissolved, cancelled or defaults, and the Division is not notified by Pelican Point CB, LLC to transfer the permit, then the responsibility for permit compliance reverts back to the property owner HDI Holdings, LLC The Division must be notified immediately of any permit ownership changes and submit a completed Name/Ownership form to the Division within 30 days Otherwise Pelican Point CB, LLC and HDI Holdings, LLC will be operating a stormwater treatment facility without a valid permit This is a violation of NC General Statue 143-215 1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $25,000 per day Records of maintenance activities must be kept and made available upon request to authorized personnel of the Division The records will indicate the date, activity, name of person performing the work and what actions were taken 7 The facilities shall be constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data 8 Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation Any deviations from the approved plans and specifications must be noted on the Certification A modification may be required for those deviations 9 All stormwater collection and treatment systems must be located in either public rights - of -way, dedicated common areas or recorded easements The final plats for the protect will be recorded showing all such rights -of -way, common areas and easements, in accordance with the approved plans Access to the stormwater facilities for inspection and maintenance shall be maintained via appropriate recorded easements at all times 10 The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below a Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc b Redesign or addition to the approved amount of built -upon area or to the drainage area c Further development, subdivision, acquisition, lease or sale of any, all or part of the protect area The protect area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought d Filling in, altering, or piping of any vegetative conveyance shown on the approved plan e The construction of any future BUA listed on the application 11 Prior to transfer of the permit, the stormwater facilities will be inspected by Division personnel The project and the stormwater facility must be in substantial compliance with all permit conditions Any items not in substantial compliance must be repaired, replaced or restored to design condition prior to the transfer Records of maintenance activities performed to date will be required Page 3 of 7 State Stormwater Management Systems Permit No SW8 070817 12 The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made III GENERAL CONDITIONS Any individual or entity found to be in noncompliance with the provisions of a stormwater management permit or the stormwater rules, is subject to enforcement action as set forth in NCGS 143, Article 21 The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction 3 In the event that the facilities fail to perform satisfactorily the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems Additional or replacement stormwater management systems shall receive a permit from the Division prior to construction 4 This permit is not transferable to any person or entity except after notice to and approval by the Director The permittee shall submit a completed and signed Name/Ownership Change Form, accompanied by the supporting documentation as listed on the form, to the Division of Energy, Mineral and Land Resources at least 60 days prior to any one or more of the following events a An ownership change including the sale or conveyance of the project area in whole or in part, except in the case of an individual lot sale that is made subject to the recorded deed restrictions, b The sale or conveyance of the common areas to a Homeowner's or Property Owner's Association, subject to the requirements of Session Law 2011-256, c Bankruptcy, d Foreclosure, subject to the requirements of Session Law 2013-121, e Dissolution of the partnership or corporate entity, subject to NCGS 57D-2-01(e) and NCGS 57D-6-07, f A name change of the current permittee, g A name change of the project, h A mailing address change of the permittee, 5 The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request Neither the sale of the project, in whole or in part, nor the conveyance of common area to a third party constitutes an approved transfer of the stormwater permit 6 The permittee grants DEMLR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility 7 The permit issued shall continue in force and effect until modified, revoked, terminated or renewed The permit may be modified, revoked and reissued or terminated for cause The filing of a request for a permit modification, revocation and re -issuance or termination does not stay any permit condition 8 Approved plans, calculations, supplement forms, operation and maintenance agreements and specifications for this project are incorporated by reference and are enforceable parts of the permit A copy of the approved plans and specifications shall be maintained on file by the Permittee at all times Page 4 of 7 State Stormwater Management Systems Permit No SW8 070817 Unless specified elsewhere, permanent seeding requirements for the stormwater controls must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual 10 The issuance of this permit does not prohibit the Director from reopening and modifying the permit, revoking and reissuing the permit, or terminating the permit as allowed by the laws, rules and regulations contained in Session Law 2008-211, Title 15A NCAC 2H 1000 and NCGS 143-215 1 et al 11 The permittee shall submit a permit renewal application request at least 180 days prior to the expiration date of this permit The renewal request must include the appropriate application, documentation and the processing fee Permit modified and reissued this the 24'h day of May 2017 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Division of Energy, Mineral and Land Resources By Authority of the Environmental Management Commission Permit Number SW8 070817 Page 5 of 7 State Stormwater Management Systems Permit No SW8 070817 Pelican Point Stormwater Permit No SW8 070817 New Hanover County Designer's Certification I, , as a duly registered in the State of North Carolina having been authorized to observe (periodically/ weekly/ full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications The checklist of items on page 2 of this form is included in the Certification Noted deviations from approved plans and specification Signature Registration Number Date SEAL Page 6 of 7 State Stormwater Management Systems Permit No SW8 070817 Certification Requirements The drainage area to the system contains approximately the permitted acreage 2 The drainage area to the system contains no more than the permitted amount of built -upon area 3 All the built -upon area associated with the project is graded such that the runoff drains to the system 4 All roof drains are located such that the runoff is directed into the system 5 The bypass structure weir elevation is per the approved plan 6 The bypass structure is located per the approved plans 7 All slopes are grassed with permanent vegetation 8 Vegetated slopes are no steeper than 3 1 9 The inlets are located per the approved plans and do not cause short-circuiting of the system 10 The permitted amounts of surface area and/or volume have been provided 11 All required design depths are provided 12 All required parts of the system are provided 13 The required system dimensions are provided per the approved plans cc NCDEQ-DEMLR Wilmington Regional Office New Hanover County Building Inspections Page 7of7 pf3_r M ,< F3a +'�'DEMLR USE ONLY- ar Date Received Fee Paid Permit Number s-/o - 00 , oo O O Applicable Rules XCoastal SW - 9 5 ❑ Coastal SW - 2008 ❑ Ph II - Post Construction (select all that apply) ❑ Non -Coastal SW- HQW/ORW Waters ❑ Universal Stormwater Management Plan ❑ Other WQ Mgmt Plan State of North Carolina Department of Environment and Natural Resources Division of Energy, Mineral and Land Resources STORMWATER MANAGEMENT PERMIT APPLICATION FORM This farm may be photocopted far use as an original I GENERAL INFORMATION 1 Project Name (subdivision, facility, or establishment name -should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc) 2 Location of Project (street address) MAY 10 2011 City Carolina Beach County BY Zip 3 Directions to project (from nearest major intersection) 4 Latitude 31 0 Oa ' 1 7 " N Longitude 77 ° Si ' 37 " W of the main entrance to the project II PERMIT INFORMATION 1 a Specify whether project is (check one) ❑New ❑Modification ❑ Renewal w/ Modificationt +Renewals with modifications also requires SWU-102 -Renewal Application Form b If this application is being submitted as the result of a modification to an existing permit, list the existing permit numberSW8 070817 , its issue date (if known)8-12-16 and the status of construction ®Not Started ❑Partially Completed* ❑ Completed* *provide a designer s certification 2 Specify the type of project (check one) ❑Low Density ®High Density ❑Drams to an Offsite Stormwater System ❑Other 3 If this application is being submitted as the result of a previously returned application or a letter from DEMLR requesting a state stormwater management permit application, list the stormwater project number, if assigned, and the previous name of the project, if different than currently proposed, 4 a Additional Project Requirements (check applicable blanks, information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748) ®CAMA Major ®Sedimentation/Erosion Control ac of Disturbed Area ❑NPDES Industrial Stormwater ❑404/401 Permit Proposed Impacts b If any of these permits have already been acquired please provide the Project Name, Project/Permit Number, issue date and the type of each permit CAMA Permit It 20-16 dated 2-8-16 Is the project located within 5 miles of a public airport? ®No ❑Yes If yes, see S L 2012-200, Part VI http //oortal ncdenr org/web/Ir/rules-and-regulations Form SWU-101 Version Oct 31, 2013 Page l of 6 III CONTACT INFORMATION 1 a Print Applicant / Signing Official's name and title (specifically the developer, property owner, lessee, designated government official, individual, etc who owns the project) Applicant/Organization Pelican Point CB. LLC Signing Official & Title Charles Poindexter II, Developer / M r.,na.e o.r b Contact information for person listed in item la above Street Address 7923 Reunion Road City Wilmington State NC Zip 28411 Mailing Address (if applicable) City State Zip Phone (910 ) 620-4672 Fax ( ) Email ccun®mac corn c Please check the appropriate box The applicant listed above is ❑ The property owner (Skip to Contact Information, item 3a) ❑ Lessee* (Attach a copy of the lease agreement and complete Contact Information, item 2a and 2b below) ❑ Purchaser* (Attach a copy of the pending sales agreement and complete Contact Information, item 2a and 2b below) ® Developer* (Complete Contact Information, item 2a and 2b below) 2 a Print Property Owner's name and title below, if you are the lessee, purchaser or developer (This is the person who owns the property that the project is located on) Property Owner/Organization HDI Holdings, LLC Signing Official & Title Robert Huth, Manager b Contact information for person listed in item 2a above Street Address 1430 Commonwealth Dr, Suite 301 City Wilmington State NC Zip 28403 Mailmg Address (if applicable) P O Box 1489 City Wrightsville Beach State NC Zip 28480 Phone (910 ) 538-6999 Fax ( ) Email bobhuth53@gmad com 3 a (Optional) Print the name and title of another contact such as the projects construction supervisor or other person who can answer questions about the project i Other Contact Person/Organization HDI Holdings, LLC Signing Official & Title David Thompson, CFO b Contact information for person listed in item 3a above Mailmg Address 1430 Commonwealth Dr, Suite 301 City Wilmington State NC Zip 28403 Phone (910 ) 619-6858 Fax ( ) Email dt1000ec rr corn 4 Local jurisdiction for building permits Point of Contact Fonn SWU-101 Version Oct 31, 2013 Page 2 of 6 1 t I. , ' IV PROJECT INFORMATION 1 In the space provided below, briefly summarize how the stormwater runoff will be treated Stormwater will be collected in stormwater collection pies that will discharge into a manifold system of 24" pipes to hold the water quality volume which will flow through a CONTECH Stonnfilter for treatment pnor 2 a If claiming vested rights, identify the supporting documents provided and the date they were approved ❑ Approval of a Site Specific Development Plan or PUDApproval Date ❑ Valid Building Permit Issued Date ❑ Other Date b If claiming vested rights, identify the regulation(s) the project has been designed in accordance with ® Coastal SW —1995 ❑ Ph II — Post Construction 3 Stormwater runoff from this project drams to the White Oak River basm 4 Total Property Area 0 97 acres 5 Total Coastal Wetlands Area acres 6 Total Surface Water Area acres 7 Total Property Area (4) — Total Coastal Wetlands Area (5) — Total Surface Water Area (6) = Total Project Area` 097 acres Total project area shall be calculated to exclude thefollowing the normal pool of impounded structures, the area between the banks of streams and rivers, the area below the Normal High Water (NHW) line or Mean High Water (MHW) line, and coastal wetlands landward from the NHW (or MHW) line The resultant project area is used to calculate overall percent built upon area (BUA) Non -coastal wetlands landward of the NHW (or MHW) line may be included in the total project area 8 Project percent of impervious area (Total Impervious Area / Total Project Area) X 100 = % 9 How many drainage areas does the project have?l (For high density, count 1 for each proposed engineered stormwater BMP For low density and other projects, use 1 for the whole property area) 10 Complete the following information for each drainage area identified in Project Information item 9 If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below Basin Informati6n­' <¢ Drainage Area 1- Drama" a Aria, Drainage Area _ ' Drama a Area'"' Receiving Stream Name CB Yacht Basin Stream Class * SB Stream Index Number * 18-87-312 Total Drainage Area (sf) 24,513 On -site Drainage Area (sf) 24,513 Off -site Drainage Area (sf) Proposed Impervious Area** (sf) 24,364 % Impervious Area** (total) 994 Im envious'*rSurface-AreaCA, i Drainage Area `� ,Diamag e Area 1 L Drama a"Area = Drainage Area" On -site Buildmgs/Lots (so 10,493 On -site Streets (sf) On -site Parking (sf) 12,061 r74n")w On -site Sidewalks (so 810 LAAV Other on -site (sf) IL Future(so 1000 Off -site (so Existing BUA*** (sf) Total (sf) 24,364 * Stream Class and Index Number can be determined at htt� aortal_ ncdenr ororg[webhaq/ys/tau/classifications Form SWU-101 Version Oct 31, 2013 Page 3 of 6 *** Report only that amount of existing BUA that will remain after development Do not report any existing BUA that is to be removed and which will be replaced by new B UA 11 How was the off -site impervious area listed above determined? Provide documentation Protects in Union County Contact DEMLR Central Office staff to check if the project is located within a Threatened & Endangered Species watershed that maybe subject to more stringent stormwater requirements as per 1 SA NCAC 02B 0600 V SUPPLEMENT AND O&M FORMS The applicable state stormwater management permit supplement and operation and maintenance (O&M) forms must be submitted for each BMP specified for this project The latest versions of the forms can be downloaded from http //portal ncdenr org/web/wq/ws/su/bmp-manual VI SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Energy, Mmeral and Land Resources (DEMLR) A complete package includes all of the items listed below A detailed application instruction sheet and BMP checklists are available from http //portal ncdenr org/web/wq/ws/su/statesw/forms_docs The complete application package should be submitted to the appropriate DEMLR Office (The appropriate office may be found by locating project on the interactive online map at http //1ortal ncdenr org/web/wq/ws/su/maps ) Please indicate that the following recurred information have been provided by initialing in the space provided for each item All original documents MUST be signed and initialed in blue ink Download the latest versions for each submitted application package from http //portal ncdenr org web/wq/ws/su/statesw/forms_docs Imtials 1 Original and one copy of the Stormwater Management Permit Apphcahon Form A5 2 Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants /1!3 Form (if required as per Part VII below) 3 Original of the applicable Supplement Form(s) (sealed, signed and dated) and O&M /VW agreement(s) for each BMP 4 Permit application processing fee of $505 payable to NCDENR (For an Express review, refer to /M http / /www envhelp org/pages/onestopexpress html for information on the Express program and the associated fees Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required application meeting) 5 A detailed narrative (one to two pages) describing the stormwater treatment/managementfor the project This is required in addition to the brief summary provided in the Project Information, item 1 6 A USGS map identifying the site location If the receiving stream is reported as class SA or the �3 receiving stream drams to class SA waters within ih mile of the site boundary, include the iA mile radius on the map 7 Sealed, signed and dated calculations (one copy) 8 Two sets of plans folded to 8 5" x 14" (sealed, signed, & dated), including a Development/Project name b Engineer and firm c Location map with named streets and NCSR numbers d Legend e North arrow f Scale g Revision number and dates h Identify all surface waters on the plans by delineating the normal pool elevation of impounded structures, the banks of streams and rivers, the MHW or NHW line of tidal waters, and any coastal wetlands landward of the MHW or NHW Imes • Delineate the vegetated buffer landward from the normal pool elevation of impounded structures, the banks of streams or rivers, and the MHW (or NHW) of tidal waters i Dimensioned property/project boundary with bearings & distances L�a h It -- I Site Layout with all BUA identified and dimensioned k Existing contours, proposed contours, spot elevations, finished floor elevationsAY ' a 2� �� a 1 Details of roads, drainage features, collection systems, and stormwater control m Wetlands delineated, or a note on the plans that none exist (Must be delineatequalifiedperson Provide documentation of qualifications and identify the per -- made the determination on the plans Form SWU-101 Version Oct 31, 2013 Page 4 of 6 ' +I �• 1 I ! 1! ' i I '$1 ' i 11 1 I f/' ,� 1 7 i I f I , r \ I ' ' I 1 7 1 1 1� ' ♦ � ( 11 ,l II )V r ,1 1 ' 1 I Itl - ' 1 t, in I r 1 r ' I , n Existing drainage (including off -site), drainage easements, pipe saes, runoff calculations o Drainage areas delineated (included in the main set of plans, not as a separate document) p Vegetated buffers (where required) Copy of any applicable soils report with the associated SHWT elevations (Please identify N/A elevations in addition to depths) as well as a map of the boring locations with the existing elevations and bormg logs Include an 8 5"x11" copy of the NRCS County Soils map with the project area clearly delineated For projects with infiltration BMPs, the report should also include the soil type, expected infiltration rate, and the method of determining the infiltration rate (Infiltration Devices submitted to WiRO Schedule a site visit for DEMLR to verify the SHWT prior to submittal, (910) 796-7378 ) 10 A copy of the most current property deed Deed book Page No /v/q 11 For corporations and limited liability corporations (LLC) Provide documentation from the NC ry/A Secretary of State or other official documentation, which supports the titles and positions held by the persons listed in Contact Information, item la, 2a, and/or 3a per 15A NCAC 2H 1003(e) The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State, otherwise the application will be returned hU / /www secretary state nc us/Corporations/CSearch asI2x VII DEED RESTRICTIONS AND PROTECTIVE COVENANTS For all subdivisions, outparcels, and future development, the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot If lot sizes vary significantly or the proposed BUA allocations vary, a table listing each lot number, lot size, and the allowable built -upon area must be provided as an attachment to the completed and notarized deed restriction form The appropriate deed restrictions and protective covenants forms can be downloaded from http //portal ncdenr org/web/Ir/state-stormwater- forms dots Download the latest versions for each submittal In the instances where the applicant is different than the property owner, it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded By the notarized signature(s) below, the permit holder(s) certify that the recorded property restrictions and protective covenants for this project, if required, shall include all the items required in the permit and listed on the forms available on the website, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DEMLR, and that they will be recorded prior to the sale of any lot VIII CONSULTANT INFORMATION AND AUTHORIZATION Applicant Complete this section if you wish to designate authority to another individual and/or firm (such as a consulting engineer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional information) Consulting Engineer Howard Resnik Consulting Firm CSD Engineering Mailing Address City Wilmington Phone (910 ) 791-4441 Email howard®csd-engmeermg com State NC Zip 28406 Fax (910 ) 791-1501 IX. PROPERTY OWNER AUTHORIZATION (if Contact Information, item 2 has been filled out, complete this section) I, (print or type name of person listed in Contact Information, item 2a) Robert Huth , certify that I own the property identified in this permit application, and thus give permission to (print or hjpe name of person listed in Contact Information, item la) Charles Poindexter, If with (print or type name of organization listed in Contact Information, item la) Pelican Point CB, LLC to develop the project as currently proposed A copy of the lease agreement or pending property sales contract has been provided with the submittal, w ich udiciLtesthe party responsible for the operation and maintenance of the stormwater system RF e!!r= MAy 10 IN BY Form SWU-101 Version Oct 31, 2013 Page 5 of I 1 ,r 1 1 r .r r 1 ,r r r __ � r ri r r 1 � r i J u r . I� r , e , 1 ' ,11 I r r,r r , r t I .} I - � I. 1 1 1 1 I }r r. . r t � rr r o . 1 � � r . rl , I 1 . r / I +/ / r t I 1 I 1. r r I I I 1 r,� � I '. ) I't 1 1 r r 4 r 1+ rl 1 - �� : . r 1 . n � C r + Ir 1 r 1 1 . � I . 1 r t r . �� q 1 r 1 1 1 r � I r r N r J r r t I r . r r r 1 1 p�) I � 1 + r I n r ' rtri r l Illr rr r � �. . . I 1 1 r 4 . I r r r r t J r 1 _J 'll ' .1 r r. ! 1 r r r t r . 1� I 7 1 i r . _ }. � r nr I/ 1 1 n r t+ II 1 q . i n ! f . +tu . (( r .. 1 n 4 tl (r .. rl Irf fl r 11i 11 � _ tlr iJl ill 1 u i } 1 1 r r} 1 � l 1 ! 1 i. / t 1 F f ' l l 1 / r 1 r r l/ I v lit I 1 ! i Ir r . 1 4 1 ar IiLa� ) r II. 1 u 11 dl 1 � r i r r 1 1 l J.. r ) 1 r I! i 1 _ � _ I _ 1 � _ _ _ _ � _ ! r It. l r 1 _ l r r _ _ I J r r I I 1 � r r 1 f 1 / r 1 fl e l 1 � r r i 1 . I 1 r _ _ _ Ir 1 r r r` ! 1 � c I! { r � 1 1 1 r r 1 % � 1 Y 1 r Y iJ I r I r I . ) . i i f t Ir rr 1 I' r lal 11 f As the legal property owner I acknowledge, understand, and agree by my signature below, that if my designated agent (entity listed in Contact Information, item 1) dissolves their company and/or cancels or defaults on their lease agreement, or pending sale, responsibility for compliance with the DEMLR Stormwater permit reverts back to me, the property owner As the property owner, it is my responsibility to notify DEMLR immediately and submit a completed Name/Ownership Change Form within 30 days, otherwise I will be operating a stormwater treatment facility without a valid permit I understand that the operation of a stormwater treatment facility without a valid pe i is a iolabon of NC General Statue 143-2151 and may result in appropriate enforcement action includm ass s nt of civil penalties of up to $25,000 per day, pursuant to NCGS 143-215 6 Signature Date -TL d o f a Notary Public for the State of %V+�') C(Ay6ira. County of ryWo �GN10)��Qj,,✓ , do hereby certify that �t:)0U ' N \Wl personally appeared before me this T Hay of 0 on and ac��owledge the � due execution of the application for a stormwater permit Witness my hand and official seal, CA i i�/�lA �Y1 /Y usARAcia.Ev NOTARYPUBUC NEW HANOVER CAUNIY, NC NIY COMMISSION IXPIRES OC'fOBER 24, 2oJ1 X APPLICANT'S CERTIFICATION SEAL My commission expires 10 IAY In I, (pent or h pe name of person listed in Contact Information, item 1a) Charles Poindexter, II certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of the applicable stormwater rules under 15A NCAC 2H 1000 and any other applicable state stormwater requirements Signature s� ('//`% 1D,ate I,, 1 1 S� _ a Notary Public for the State otf� NL1J trl (tiA VU� I i�C County of IVY�11 �(A Vl 1�1� ✓, do hereby certify that C�AJi C �� i f1Lte e✓i ( personally appeared before me this day of D�� 02N n , and a nowledge the, ndue execution of the application for a stormwater permit Witness my hand and official seal ✓ I JI /1/liA iX X/ V USA RACK0 NOTARYPUBUC NEW HANOVER COUNTY, NC MY COMMISSION IXPIRES OCTOBER 24,20U SEAL My commission expires MAY 10 21717 BY Form SWU-101 Version Oct 31, 2013 Page 6 of 6 MEMORY TRANSMISSION REPORT TIME 05 24-2017 10 24 FAX NO 1 9103502004 NAME Mainfax FILE NO 368 DATE 05 24 10 21 TO a 97911501 DOCUMENT PAGES 9 START TIME 05 24 10 21 END TIME 05 24 10 24 PAGES SENT 9 STATUS OK STORMWATER MANAGEMENT CALCULATIONS EC EIVE for MAY 2 2 20117 BY -- PELICAN POINT PREPARED FOR PELICAN POINT CB, LLC. 7923 Reunion Road Wilmington, NC 28411 Prepared by CSD ENGINEERING PO Box 4041 Wilmington, NC 28406 Phone 910 791-4441 Fax 910 791-1501 License # C-2710 CAROB / ��J\Q\.� oFEss/oy��, �✓ _ # SEAL jL 025483 — iyO��VQ111ty Howard Resnik, P E C o NTECH® ENGINEERED SOLUTIONS Design Engineer Date Site Information Project Name Project State Project Location Drainage Area Ad Impervious Area, Ai Pervious Area, Ap % Impervious Runoff Coefficient Rv Water Quality Volume Calculations Design storm rainfall depth Rd Water quality volume WQV Storage Component Calculations Capture 75% of WQV Pretreatment credit (estimated or calculated) %pre Mass loading calculations Mean Annual Rainfall, P Agency required % removal Percent Runoff Capture (% capture) Mean Annual Runoff Vt Event Mean Concentration of Pollutant EMC Annual Mass Load, Mtgt,( Filter System Filtration brand Cartridge height Cartridge Quantity Calculation Mass removed by pretreatment system Mp. Mass load to filters after pretreatment Mp,,,1 Estimate the required filter efficiency Efiltar Mass to be captured by filters Mflt,r Maximum Cartndge Flow rate Q., Mass load per cartridge M.d (Ibs) Number of Cartridges required Nm,,, Maximum Treatment Capacity SUMMARY Determining Number of Cartridges for Volume -Based Design in NC LRS Blue Cells = Input 5/19/2017 Black Cells = Calculation Pelican Point ECEIVS North Carolina Carolina Beach r MAY 2 2 20V 0 56 ac 056 ac 000 BY 99% 094 =0 05+0 9*(Ai/Ad) 1 0 in 1,911 ft3 =Ad*Rv*Rd*(43560/12) 1,433 113 =0 75*WQV 30% 57 in 85% 90% 98,505 ft'=P*Ad*Rv*(43560/12)*%capture 70 0 mg/I (Suggestion UseWforresidenaal Mfor Commemial 100fortndustnal 430 20 Ibs =EMC*Vt'(28 3)*(0 000001)*(2 2046) StormFilter 18 in 129 Ibs =Mtotal * %removal 301 Ibs =Mtotal - Mpre 79% =1+(%removal - 1)/(1 - %pre) 237 Ibs =Mpassl * Efilter 75 gpm =q * (7 5 ft2/cartr(dge) 36 Ibs =lookup mass load per cartridge 7 =ROUNDUP(Mfilter/Mcart 0) 012 =Nmass*(Qcart/449) Maximum Treatment Flow Rate cfs 012 Cartridge Flow Rate gpm 75 Number of Cartridges 7 02008 CONTECH Stomiwater Solugons wnte hstomiwater wm 1 of 1 May 22, 2017 Christine Hall N C Department of Environment And Natural Resources DEMLR 127 Cardinal Drive Extension Wilmington, NC 28405 Re Stormwater Permit Modification Comment Response Pelican Point (SW8 070817) New Hanover County CSD Project No 17-0395 Dear Christine CSD ENGINEERING AfAY 22 2417 We are in receipt of your comments dated 5/18/17 for Pelican Point The first item has been resolved, as you informed us that you had located the 0&M Item two is addressed in this submittal Enclosed please find — One (1) copy of the revised Contech Stormfilter Design Sheet / Stormwater Calculations Thank you for your assistance Please contact us if you have any questions or require any additional information Sincerely, Mike Broyhill cc Pelican Point CB, LLC 3805 Cherry Avenue Wilmington, NC 28403 - 910 7914441- www csd-engineering com — License # C-2710 �/�,■ CSD V' FNtlMEENXO Hall, Christine From Hall, Christine Sent Thursday May 18 2017 348 PM To Mike Broyhill Cc Rodney Wright Subject RE request for additional information - Pelican Point, SW8 070817 My apologies I had flipped through the items 2 or 3 times and didn't see it When I lust looked, I found it stuck to another document Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct christine hall@ncdenr gov 127 Cardinal Drive Ext Wilmington NC 28405 Nothing Compares, Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties From Mike Broyhill [madto mike@csd-engineering com] Sent Thursday, May 18, 2017 2 54 PM To Hall, Christine <Christine Hall@ncdenr gov> Cc Rodney Wright <rodney@csd-engineering com> Subject request for additional information - Pelican Point, SW8 070817 Christine, Rodney informed me that you could not find the original 0&M in the package I am sure it was there I have attached a copy of it that I scanned before I delivered the submittal package back to you on the 101" I hope this will be sufficient Let me know if you need anything else Thank you for your assistance Mike Mike Broyhill Engineering Technician/Inspector (� � CSD Energy Mineral& Land Resources ENVIRONMENTAL QUALITY May 18, 2017 Charles C Poindexter Pelican Point CB, LLC 7923 Reunion Rd Wilmington NC28411 ROY COOPER Governor MICHAEL S REGAN \ Secretary TRACY DAVIS Director ❑, Manger Robert I loth Manager Developer HDI Holdings, LLC, Property Owncr 5929 Market St Wilmington, NC 28405-3615 Sub3ut Request for Additional Information Storm" ater Project No SW8070817 Pelican Point NcK Ilanover County Dear Mr Poindexter and Mr Huth fhe Wilmington Regional Office received and accepted a modified Express State Stormwater Management Permit Application for Pelican Point on May 10 2017 A preliminary in-depth review of that information has determined that the application is not complete The following information is needed to continue the stormwater review I 15A NCAC 0211 1042(2)0) An operation and maintained (O&M) agreement could not be found in the submittal Please provide a signed and notarized O&M agreement If it desired to use the DEMLR provided O&M agreement please note that Contech stormfilters are included under the proprietary system category ✓2 15A NCAC 02H 1042(2) Please confirm the water quality volume is presented consistently between the supplement, Contech results, and the CDS calculations Also, please confirm that there are no rounding errors causing the inconsistencies 3 Due to the relatively minor nature of these comments, the express additional information review fee has been waived Pleasc keep in mind that changing one number may change other numbers and require the calculations, supplements, and other supporting documentation to be updated Verify all numbers are correct to ensure consistency in the application documents Please note that this request for additional information is in response to a preliminary review I he requested information should be received in this Office prior to May 25, 2017, or the application will be returned as incomplete If the project is returned and you wish to re -submit to the Express Program you will need to reschedule the project through the Express Coordinator for the next available review date and will need to resubmit all of the required items at that time, including the application fee If you need additional time to submit the information, please email or fax your request for a time extension to the Division at the email address or fax number at the bottom of this letter 1 he request must indicate the date by which you expect to submit the required information, which shall be no later than 5 business days past the original due, date I he construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation ofNCGS 143-215 1 and is subject to enforcement action pursuant to NCGS 143-215 6A State of North Carolma I Cnvironmental Quaht) I Energy Mineral and Land Resources Wilmington Regional Ofnct 1127 Cardinal Drive Extension I Wilmington NC 28405 910 796 7215 State Stormwater Perm ltNo SW8 070817 Page 2 of 2 Please label all packages and cover letters as Express and reference the project name and State assigned project number on all correspondence If you have any questions concerning this matter, please feel free to call me at (910) 796-7215 or email me at Christine hall@ncdenr gov Sincerely wjl� Christine Ifall Cnvtronmental Engineer GDS/canh \\\Stormwatcr\Permits R 1rojects\2007\070817 1 fD\2017 05 addmfo 070817 cc I loward Resnik, CSD I'ngmeering Wilmington Regional Office Stonnwater File State of Nnrtll Carolina I rnvn onOx ntal Quality I Energy Mmcral and Land R( som ees Wiliningtun Region al Office 1 127 Cardinal Drive Ex le nson I N11mington NC 28405 910 796 7215 III Hall, Christine From Hall, Christine Sent Thursday, May 18 2017 12 57 PM To Howard Resnik (howard@csd-engineering com), Rodney Wright, Charles Poindexter Cc Weaver, Cameron Subject request for additional information - Pelican Point, SW8 070817 Attachments 2017 05 addinfo 070817 pdf Gentlemen, Attached is a pdf of the request for additional information for the subject project There are lust two minor items that need to be addressed Please let me know if you have any questions or concerns Thanks, Christine Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct chnstine hall@ncdenr gov 127 Cardinal Drive Ext Wilmington, NC 28405 —i>-Nothing Compares, Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties Corporations Division Page 1 of 1 MIT110.11771min North Carolina Elaine F Marshall DEPARTMENT OFTHE Secretary SECRETARY OF STATE PO Box 29622 Raleigh NC 27626-0622 (919)807 2000 Account Login Create View Document Filings File an Annual Report Amend a Previous Annual Report Print a Pre -Populated Annual Report form Corporate Names Legal Pelican Point CB LLC Limited Liability Company Information Sosld Status Annual Report Status Citizenship Date Formed Fiscal Month Registered Agent Corporate Addresses 1530809 Current Active Current Domestic 7/14/2016 January Poindexter Charles C II Principal Office 7923 Reunion Road Wilmington NC 28411 9266 Reg Office 7923 Reunion Road Wilmington NC 28411 9266 Reg Mailing PO Box 1489 Wrightsville Beach NC 28480 1489 Mailing PO Box 1489 Wrightsville Beach NC 28480 1489 Company Officials All LLCs are managed by their managers pursuant to N C G S 57D 3 20 Chief Financial Officer David Thompson PO Box 1489 Wrightsville Beach NC 28480 Account https //www sosnc gov/Search/profcorp/12278138 5/18/2017 Corpordtlons Division Page 1 of 1 North Carolina Elaine F Marshall DEPARTMENT OF THE Secretary SECRETARY OF STATE PO Box 29622 Raleigh NC 27626-0622 (919P07 2000 Click Here To View Document Filings File an Annual Report Amend a Previous Annual Report Print a Pre Populated Annual Report form Corporate Names Legal HDI Holdings LLC Limited Liability Company Information Sosld 0849936 Status Current Active Annual Report Status Current Citizenship Domestic Date Formed 6/7/2006 Fiscal Month December Registered Agent Huth Robert W Corporate Addresses Principal Office 1430 Commonwealth Dr Suite 301 Wilmington NC 28403-0365 Reg Office 1430 Commonwealth Dr Suite 301 Wilmington NC 28403 0365 Reg Mailing PO Box 1489 Wrightsville Beach NC 28480 1489 Mailing PO box 1489 Wrightsville Beach NC 28480 1489 Company Officials All LLCs are managed by their managers pursuant to N C G S 57D 3 20 Manager Robert W Huth P O Box 1489 Wrightsville Beach NC 28480 Account Login Create Account https//www sosnc gov/Search/profcorp/7987150 5/18/2017 STORMWATER MANAGEMENT CALCULATIONS for PELICAN POINT PREPARED FOR PELICAN POINT CB, LLC 7923 Reunion Road Wilmington, NC 28411 Prepared by &11 CSD ENGINEERING PO Box 4041 Wilmington, NC 28406 Phone 910 791-4441 Fax 910 791-1501 License # C-2710 CARW,/ ojsssioy�� SEALCL _ 025483 — iy �'yQINE�p fR Howard Resnik, P E 'fly/n MAY 10 2017 BY CSD ENGINEERING Storm Water Narrative May 2017 PROJECT NAME Pelican Point (SW8 070817) PROJECT DESCRIPTION This submittal is for a major modification to change the approved infiltration trench BMP to a CONTECH Stormfilter Currently the permitted design has the infiltration trench located underneath the proposed building The owners would like to change the design so the stormwater system is not located underneath the building The project will have direct access onto DOT maintained North Lake Park Blvd The project is not located within X mile of SA waters and water and sewer will be available through the Town of Carolina Beach Stormwater from the site will dram to Carolina Beach Yacht Basin, SB located in the White Oak River Basin (Index # 18- 87-31 2) The project is high density and will be treated with a high density BMP The site will utilize a collection system that discharges into an underground chamber system designed to contain the required Water quality volume then release the water through a CONTECH Stormfilter Chamber system for treatment Proposed impervious for the site is 99% PROJECT BMP CONTECH Stormfilter STORMWATER ENGINEER/CONSULTANT CSD-Engineering PO Box 4041 Wilmington, NC 28406 Rodney Wright rodney@csd-engineering com 910 7914441 office 910 7911501 fax 3805 Cherry Avenue -Wilmington, NC 28403 - 910 7914441- www csd-engineering com — License # C-2710 & I CSD wnxeewxa 0 PROJECT DATA: Existing Site Data (within Stormfilter drainage delineation) Existing wetlands 0 0 sf (0 0 acres) Existing uplands 24,513 sf (0 56 acres) Total proposed project area 24,513 sf (0 56 acres) Proposed Site Data Proposed Building 10,493 sf (0 24 acres) Proposed parking 12,061 sf (2 57 acres) Proposed pool deck 810 sf (0 02 acres) future 1,000 sf (0 02 acres) Total proposed impervious area 24,364 sf (0 56 acres) Soil Types Within Project Limits Abbreviation Type and Description Hydrologic Group Area U Urban Land A 0 56 ac (See attached sods map) Pelican Point PROPOSED IMPERVIOUS ON SITE WITHIN DRAINAGE AREA TO STORMFILTER area to basin = 24 513 sf = 0 56 acres Asphalt 12 061 sf 0 28 ac building = 10 493 sf 0 24 ac concrete pool deck = 810 sf 0 02 ac future = 1 000 sf 0 02 ac total = 24,364 sf 0 56 ac total imp = 24 364 sf 0 56 ac percent imp = 99 4 % 1 0" VOLUME DETERMINATION DETERMINE IMPERVIOUS PERCENTAGE TO CARTRIDGE SYSTEM DETERMINE RUNOFF COEFFICIENT (Rv) I = 994 percent impervious Rv = ?(runoff coefficient inches per inch) Rv= 005+0009(1) Rv = 094 infin DETERMINE VOLUME design storm = 1 inch Rv = 094 mlm drainage area = 056 acres volume = 9 volume = (design storm)(Rv)(drainage area) volume = 0 04 acre-ft 1 0" volume = 1,911 cf of required storage volume Adjusted Water Quality Volume = 1,433 cf that must be contained PIPE STORAGE - STORAGE TABLE pipe size (in) = 24 pipe length (ft) = 470 pipe invert elevation (ft) = 3 TOTAL PIPE WD area/DA2 STAGE ELEVATION STORAGE (FT) (CF) 0 0 0 000 300 - 0 1 00409 0200 320 77 02 01118 0 400 340 210 03 01982 0 600 360 373 04 02934 0 800 380 552 05 03927 1 000 400 738 06 04920 1200 420 925 07 - 05872 1 400 440 1 104 08 06736 1 600 460 1 266 09 07445 1 800 480 1 400 1 07854 2000 500 1 477 1 0" VOLUME STORAGE (elev 5 0) = 1,477 cf CSD ENGINEERING PO BOX 4041 WILMINGTON NC 215408 DRAWDOWN TIME reference CONTECH Discharge Flow Rate Spreadsheet (attached in calcs) Discharge = 0 058 CFS or 5 011 CIF/DAY Storage Required =1,433 CF or 1 433 / 5 011 = 0 29 days CSD ENGINEERING PO BOX 4041 WILMINGTON NC 28406 w���%u�ewu• y i � - &vr■ .i 4► � _ ■ ram►.. - CONSTRUCTION PRODUCTS INC. Pelican Point Carolina Beach, NC Discharge Flow Rate from StormFilter Volume StormFilter Restrictor Disc — Dia = 0 43" = 0 037' At 10' of Head The Volume StormFilter restrictor disc is calibrated to flow at 7 5 gpm at 10' of head (1 gpm/sf or less for all cartridge sizes) Q = M 2Gh r 0 037 2 l )( ) Q = (0 61) 4 � 2(32 2 10 Q = 0 017cfs = 7 5GPM Pelican Point Wont Case During the worst case scenario, there is 2 5' of head available on the orifice when the water quality elevation is reached at elevation 5 0' Q = cA 2Gh Q = (0 61)r 0 0372 )TJ 2(32 2)(2 5) Q = 0 008cllfs = 3 74GPM So, with 2 5' of head available, each cartridge will discharge 3 74GPM, or 0 008 cfs Since 3 74GPM is less than the 1 GPM/sf flow rate of 7 5 GPM for the 18" Cartridge, the mass loading calculations are preserved and 7 cartridges are suitable for this site With 7 cartridges, the total StormFilter discharge outflow rate is 0 058 cfs during the worst case scenario www contechstormwater com CoNli CMPDM � n.s��..e.w.r.. T1 orte is- CON SPAN' cMv oEhinro" SYSTEMStorm Filter OUTENTIDN H''gTE9� A��%uTCAU' Sk CONSTRUCTION PRODUCTS INC. Equivalent Orifice Diameter Sometimes it is desirable to establish an equivalent orifice diameter to represent the StormFilter in routing calculations The following equations back -calculate from the total worst case StormFdter flow rate and head to determine an equivalent orifice diameter that can be used to represent the StormFdter when designed on a volume basis Q = cA 2Gh z 0 058 = (0 61) n 2(32 2)(2 5) D=0098'=117" This equivalent orifice however is not a physical orifice It is simply a method for accounting for the flow through the Volume StormFdter in routing calculations when required www contechstormwater corn AMMO.0V YUrt�S- CON SPA11r o� ��+ Stormhlter M�eYBTMIM (ATE Ip, RD O PO "&F TRAIL O mS I SEAFARER DR MILITARY OCEAN IAR11111 1AII)l 11 TML SUNNY POINT MN 63 MILS GN 1 ' 39 29 MILS UTM GRID AND 2013 MAGNETIC NORTH DECLINATION AT CENTER OF SHEET 9Ir CAROLINA BEACH, NC 2013 11000 0 HIM "vx 4()',Ll 300 MW Kaj 900] Iff,W Sud Ma�New Hanover Counfy North Carolina IPobcnn Pomp F a �' lty�Smk-1.Wlf Mxm ma tiitgx(11"x 2.Sl n+ai r r AMn.'m;a^m Vt^FY-sv Cmiv mM-aS ✓vGSW ;J�03 li1MG 1'YlNL 4: 1 y n Natural Resources Web Soil Survey 54 2017 Conservation Service Nations! Cooperative Sea Survey Page 1 of 3 May 9, 2017 Christine Hall N C Department of Environment And Natural Resources DEMLR 127 Cardinal Drive Extension Wilmington, NC 28405 Re Stormwater Permit Modification Pelican Point (SW8 070817) New Hanover County CSD Project No 17-0395 Dear Christine CSD ENGINEERING ECEI E MAY r m 2017 BY II qJ This submittal is for a modification to the existing stormwater permit for Pelican Point Enclosed please find — Two (2) copies of revised sheets ECl — EC4, Drainage Area and Grading Plan — One (1) copy of the Stormwater Calculations — One (1) original and one (1) copy of the Stormwater Management Permit Application Form — One (1) copy of the Contech Stormfilter Supplement — One (1) original and one (1) copy of the Deed Restrictions — One (1) original O & M form — $4,000 Review Fee, Check #1001 Thank you for your assistance Please contact us if you have any questions or require any additional information Sincerely, Mike Broyhill cc Pelican Point CB, LLC 3805 Cherry Avenue - Wilmington, NC 28403 - 910 7914441- www csd-engineering com — License # C-2710 (`_^)/,■ CSD V- I FNGMEENNO Coastal Management ENVIRONMENTAL QUALITY MEMORANDUM TO Heather Coats DCM Major Permit Assistant Coordinator, Wilmington FROM Courtney Spears 0 DCM Field Representative, Wilmington THRU Debra D Wdson�)Ll ) DCM District Manager, Wilmington DATE April 4, 2017 ROY COOPER Governor MICHAELS REGAN Secretary BRAXTON C DAVIS Director 1z 1W E APR 05 2017 SUBJECT Permit Modification Request to State Permit No 20.16, HDI Holdings, LLC, 402 N Lake Park Blvd, Carolina Beach, in New Hanover County Mr Michael White acting agent for HDI Holdings, LLC, is requesting a minor modification to State Permit No 20-16, for the expansio_and repositioning of thin .rmlttP wt bnlldmg, removal of a portion driveway, reconfiguration of the pier, floating dock, and walkway, reduction of the pool deck, and extension of the bulkhead State Permit No 20-16 was originally issued February 8,2016 for construction of a docking facility adjacent to Myrtle Grove Sound, a bulkhead, excavation, and upland development This permit is currently due to expire on December 31, 2019 This office has no objection to the modification of State Permit No 20-16 Mr White has submitted a check (check No 1011) in the fee amount of $100 By copy of this memo, DCM is requesting that the USACE, DWR, and DEMLR provide any comments that your agency may have on the proposed project to Heather Coats of DCM's Wilmington office within 14 days of receipt of this memo Enclosures cc DCM-MHC Tyler Crumbley, USACE Robb Mars, DWR Linda Lewis, DEMLR Jeremy Hardison, LPO State of North Carolina I Environmental Quality I Coastal Management Wilmington Office' 127 Cardmal Drive E#enswn I Wilmington Vorth Carolina 28405 9107%7215 To NCDEQ Division of Coastal Management Attn Courtney Spears 127 Cardinal Drive Ext Wilmington, NC 28405-3845 From RHI Holdings, LLC C/O Michael White (Agent) 6 Sandpiper St Wrightsville Beach, NC 28480 Re Pelican Point #20-16 / CAMA Minor Modification Date April 4, 2017 Via Hand Delivery Ms Spears, On behalf of my client and owner of the proposed "Pelican Point" project, HDI Holdings LLC, we are requesting a minor modification to our existing CAMA permit #20-16 The original srteplan with noted changes, the plans depicting the changes and copy of certified mailing of notification/waiver sheet provided by Division of Coastal Management have been included The proposed changes under this minor modification are highltted in yellow and notated in red on the original The proposed building changes include • The expansion of the footprint of the building by approximately 3' in width through the main body of the building • The building will also be repositioned in the center of the property creating new setbacks from the side property lines of approximately 17' each on the north and south side of the building • The driveway extending along the north side of the building has been eliminated and the new end of pavement line is noted • Moved storm -water storge from under building and into parking area with slight modification to parking layout In addition to the change in the building footprint and setbacks, there have been some minor modifications to the water -dependant structures as well • A separate drawing has been provided (Bulkhead and Pier Layout Schematic) which details these changes • The modifications shown include the reconfigured pier head which was previously long and narrow and vaned in width which is now square in shape • The floating dock has been extended in an "L" shape alongside of the pier head and connecting back to the original floating dock RECEIVED DCM WILMINGTON, NC APR 0 4 2017 • The previously shown wooden walkway running parallel to and behind the bulkhead wall has been eliminated and the wooden walkway to the pier from the pool area has been re- aligned to connect the wood pool deck directly to the pier with no offset as previously shown • The bulkhead wall has also been extended north at an angle to terminate at the adjecent property, this wall was previously shown as "future bulkhead wall" with a dashed line • A new detail has been provided on the engineered Bulkhead and Pier Plan (A/S2 0) showing the option for contractor to place rip -rap at the base of the bulkhead to reduce sheet pile length to 14' • The size of the wood pool deck within the 30' MHWL Setback has been reduced in size to be less than 200 square feet within the setback (187 sq ft ) NOTE The 30' MHWL setback has been confirmed and platted from the basin bulkhead on the adjeacent property (south) Notices of these proposed changes were sent via certified mail with return reciept to the adjacent riparian owners listed here Mr Dennis Barbour c/o CB Marina 620 St Josephs St Carolina Beach, NC 28428 Mr and Mrs Don Greeson 400 N Lake Park Blvd Carolina Beach, NC 28428 If you have any questions or concerns regarding these changes please contact me directly, my email address is michaelwaurbansmartgrowth net and phone (910) 612-1202 Sincerely Michael C White Hollingsworth & White, Inc General Contractors RECEIVED DCM WILMINGTON, NC APR 0 4 2017 r Hall, Christine From Howard Resnik <howard@csd engineering com> Sent Wednesday, March 22 2017 1118 AM To Hall, Christine, Charles Poindexter Cc Weaver Cameron, Rodney Wright Contact Subject RE Pelican Point - SW8 070817 1995 rules We should remain at or under the originally permitted BUA Thanks Howard Resnik, PE, LEED® AP CSD tl 3805 Cherry Avenue Wilmington, NC 28403 910 791 4441 office 910 540 0959 mobile 910 791 1501 fax www csd-engineering com PLEASE NOTE THAT OUR EMAIL ADDRESSES HAVE CHANGED My new email address is howard@csd- engineering com Please update my contact information for future correspondence Thank you It is the professional opinion of CSD Engineering that this electronic information provides design information current as of the date of its release It is the responsibility of the receiver of this document to examine it and determine whether it is the information requested In the deliverance of this file we make no promise as to the usability or compatibility of this file This file shall not be considered a certified document From Hall, Christine [mailto Christine Hall@ncdenr gov] Sent Wednesday, March 22, 2017 10 55 AM To Howard Resnik <howard@csd-engineering com>, 'Charles Pomdexter' <ccpii@mac com> Cc Weaver, Cameron <cameron weaver@ncdenr gov>, Rodney Wright Contact <rodney@csd-engineering com> Subject RE Pelican Point - SW8 070817 This permit was originally approved under the 1995 version of the rules As long as you are not increasing the BUA or size of the stormwater measure, then the project can remain vested to those rules However, there is the option of applying under the 2008 set or the 2017 set Which set will this project be attempting to apply under? Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct chnstine hall(@ncdenr gov 127 Cardinal Drive Ext Wilmington NC 28405 -% Nothtng Compares... Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties From Howard Resnik [mailto howard csd-engineering com] Sent Wednesday, March 22, 2017 10 52 AM To Hall, Christine <Christine Hall@ncdenr gov>, 'Charles Poindexter' <ccpit@mac com> Cc Weaver, Cameron <cameron weaver@ncdenr gov>, Rodney Wright Contact <rodnev@csd-engineering com> Subject RE Pelican Point - SW8 070817 Christine, Are you asking new/recent rule change new rules vs old rules, or older rule change? We are redesigning utilizing a Contech Storm Filter So we want to go with whichever rules require less storage, hence minimizing underground storage of stormwater upstream of the filter vault Howard Resnik, PE, LEED" AP O I csd 3805 Cherry Avenue Wilmington NC 28403 910 7914441 office 910 540 0959 mobile 910 791 1501 fax www csd-engineering com PLEASE NOTE THAT OUR EMAIL ADDRESSES HAVE CHANGED My new email address is howard@csd- engineering com Please update my contact information for future correspondence Thank you It is the professional opinion of CSD Engineering that this electronic information provides design information current as of the date of its release It is the responsibility of the receiver of this document to examine tt and determine whether it is the information requested In the deliverance of this file we make no promise as to the usability or compatibility of this file This file shall not be considered a certified document From Hall, Christine [mailto Christine Hall@ncdenr gov] Sent Wednesday, March 22, 2017 9 58 AM To Howard Resnik (howard@csd-engineering com) <howard@csd-engineering com>, Charles Poindexter <ccpii@mac com> Cc Weaver, Cameron <cameron weaver@ncdenr gov> Subject Pelican Point SW8070817 Howard, Cameron approached me with the express request for a modification to the subject project Can you confirm which set of rules are you attempting to apply under? Thanks] Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality , 910 796 7215 office 910 796 7335 direct chnstine hallCc ncdenr gov 127 Cardinal Drive Ext Wilmington NC 28405 0- --:'"Nothing Compdres <_ Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties No virus found in this message Checked by AVG - www av g com Vernon 2016 0 8007 / Virus Database 4767/14162 - Rcicase Date 03/22/17 No virus found in this message Checked by AVG - www av g com VLrsion 2016 0 8007 / Virus Ddtabast, 4767/14162 - Rcicase Dale 03/22/17 3 0 Fo DEO Use ONLY / Rev e«e North Carolina Department of Environmental Quality aQ1 see Request for Express Permit Review mein,.EO. onf,� FILL IN all the information below and CHECK the Permits) you are requesting for express review Call and Email the completed form to the Permit Coordinator along with a completed DETAILED narrative, site plan (PDF file) and vicinity map (same items expected in the application package of the project location Please include this form in the application package • Asheville Region Alison Davidson 828 296 4698,ahson davidson(i ncdenrgov related to this Project • Fayetteville or Raleigh Region David Lee 919 791 4203, davd lee(iilncdenr goy • Mooresville or Winston Salem Marcia Allocco 704 235 2107, marcia alloccofaMcdenr goy SW 070817 Washington Region Lyn Hardison 252 948 3842 orlon hardisonncdenrgov Sw (d SW A[Csz • Wilmington Region Cameron Weaver 910 796 7303 or Cameron weavertgncdenr goy NPDES NOTE Project application received after 12 noon will be stamped in the following work day wQ NPDES _ f2 I\ 1 Project Name PELICAN POINT County NEW HANOVER 'Ai0_ Applicant CHARLES POINDEXTER Company HDI HOLDINGS LLC E&S_ Address PO BOX 1489 City WRIGHTSVILLE BEACH, State NC Zip 28480 E&S Phone 910 620 4672 Fax _ _ Email cc n@mac com Other Physical Location 400 N LAKE PARK BLVD CAROLINA BEACH NO Project Drains into SB waters - Water classification 18 87 312 (DWR Surface Water Classifications Mao) Project Located in WHITE OAK River Basin Is project draining to class ORIN waters? n within X, mile and draining to class SA waters N or within 1 mile and draining to class HOW waters? N EngmeerlConsultant HOWARD RESNIK Company CSD ENGINEERING Address PO BOX 4041 City WILMINGTON Stale NO Zip 28406 _ Phone 910 791 4441 Fax 910 791 1501 Email howard@csd engineering com PLEASE PROVIDE ESTIMATED INVESTMENT AND EXPECTED EMPLOYMENT, IF AVAILABLE 1 3 JOBS SECTION ONE REQUESTING A SCORING MEETING ONLY ❑ Scoping Meeting ONLY ❑ DWR ❑ DCM ❑ DEMLR ❑ OTHER SECTION TWO CHECK ONLY THE PROGRAM IS) YOU ARE REQUESTING FOR EXPRESS PERMITTING ❑ 401 Unit ❑ Stream Origin Determination _ # of stream calls - Please attach TOPO map marking the areas in questions ❑ IntermitlentlPerennial Determination _ # of stream calls - Please attach TOPO map marking the areas in questions ❑ 401 Water Quality Certification ❑ Isolated Wetland (_linear fl or _acres) ❑ Riparian Buffer Authorization ❑ Minor Variance ❑ Major General Vanance ® State Stormwater ❑ General ❑ SFR ❑ SFR < 1 ac ❑ Bkhd & Bl Rmp, ❑ Clear & Grub, ❑ Uldity ❑ Other ❑ Low Density ❑ Low Density Curb & Gutter _ # Curb Outlet Swales ❑ Off site [SW (Provide permit #)) ❑ High Density Detention Pond _ # Treatment Systems ❑ High Density Infiltration _ #Treatment Systems ❑ High Density Sio Retention _ # Treatment Systems ❑ High Density -SW Wetlands _ # Treatment Systems ® High Density Other _ # Treatment Systems/® MOD ® Major ❑ Minor ❑ Plan Revision ❑ Redev Exclusion SW (Provide permit #) ❑ Coastal Management ❑ Excavation & Fill ❑ Bridges & Culverts ❑ Structures Information ❑ Upland Development ❑ Marina Development ❑ Urban Waterfront ❑ Land Quality ❑ Erosion and Sedimentation Control Plan with acres to be disturbed (CK # & Amt (for DEC use)) SECTION THREE - PLEASE CHECK ALL THAT IS APPLICABLE TO YOUR PROJECT (for both scopinq and express meeting request) Wetlands on Site ® Yes ❑ No Wetlands Delineation has been completed ® Yes ❑ No US ACOE Approval of Delineation completed ® Yes ❑ No Received from US ACOE ® Yes ❑ No I ni DI D u.e Fee Split for multiple permits Check# Buffer Impacts ❑ No ❑ YES acre(s) Isolated wetland on Property ❑ Yes ❑ No 404 Application in Process wl US ACOE ❑ Yes ❑ No Permit Fee Amount SUBMITTAL DATES Fee I SUBMITTAL DATES Fee CAMA $ Variance (❑ Mal ❑ Min) S SW (❑ HD, ❑ LD, ❑ Gen) $ 401 S Los $ Stream Deter S NCDEQ EXPRESS March 2016 CSD ENGINEERING Storm Water Narrative March 2017 PROJECT NAME Pelican Point (SW8070817) PROJECT DESCRIPTION This submittal is for a major modification to change the approved infiltration trench BMP to a CONTECH Stormfilter Currently the permitted design has the infiltration trench located underneath the proposed building The owners would like to change the design so the stormwater system is not located underneath the building The project will have direct access onto DOT maintained North Lake Park BLVD The project is not located within % mile of SA waters and water and sewer will be available through the Town of Carolina Beach Stormwater from the site will drain to Carolina Beach Yacht Basin, SB located in the White Oak River Basin (Index # 18 87-31 2) The project is high density and will be treated with a high density BMP The site will utilize a collection system that discharges into an underground chamber system designed to contain the required Water quality volume then release the water through a CONTECH Stormfilter Chamber system for treatment Proposed impervious for the site is 58% PROJECT BMP CONTECH Stormfilter STORMWATER ENGINEER/CONSULTANT CSD Engineering PO Box 4041 Wilmington, NC 28406 Rodney Wright rodnev@csd engineering com 910 7914441 office 910 7911501 fax 3805 Cherry Avenue Wilmington NC 28403 9107914441 www csd engineering com—License#C 2710 ! ICSD �vEvnxes�na AL LATE PARK IRO • r f0�x`Q1SE HgT�Rf TRAIL LO 1 X`1 r`I 25 2 / 421 ti /+— Swfe+e Wtor Qeallimbom 1 'T.[j, 25. / '+�. !, _sr it 18 87 3 _ f��� �I o I%/^....,,,� 97E Ca of Del: -25i CI_ ® POr ..r ^e DC2^cD nSr -c ant .^rmc_ - /' / (.AROI INJ �' 1 tl rem,�es cc ass r< 1311,A(A1 PC n Of nc e5 rar Ce o11. Inn i[•e / % „�A hOT�re O �'le CE(Cl ne 1 t ATIAN�j`-ti �r'9Ct ra,hr BZS r ♦O 3 ' - �f tt po^ nr 4esaa� ic-m - t ` '�Giliil I"ITIV r Sa Jane 30 �037— __ ( 7 h to 1 5CAFAR� F R� e i MILI fARY OCII AN 1 `~ CARDLINA SANDS DR -/ 1M1 SUiVNYY0111 I_ tf 47ilrw/�>i M, 9 11 163 MILS GN 1 39 29 MILS CAROLINA BEACH, NC 2013 UTM GRID AND 2013 MAGNETIC NORTH DECLINATION AT CENTER OF SHEET 1000 0 1000 2000 3000 4000 50�fi000 7000 80N 9000 10000 FEET LOCATION MAP I FI /� i LEGEND ®- n O�ouu�rmw� vmura 511E h BUl(D NG OA iA a Its 4 Pilo lx4' % + GENERAL NOTES �uOMAPE NO2C PAF G NOES