Loading...
HomeMy WebLinkAboutSW8070226_HISTORICAL FILE_20100916STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO SW8 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS IV HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 2 o I o 001 I u YYYYMMDD NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor September 16 2010 Wright Holman Member Cypress Coex LLC 7036 Wrightsville Ave Suite 101 Wilmington NC 28403 Division of Water Quality Coleen H Sullins Director Subject State Stormwater Management Permit No SW8 070226MOD Cypress Station High Density Commercial Wet Detention Pond Project Pender County Dear Mr Holman Dee Freeman Secretary The Wilmington Regional Office received a complete Stormwater Management Permit Application for Cypress Station on August 30 2010 Staff review of the plans and specifications has determined that the protect as proposed will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H 1000 and Session Law 2008 211 We are forwarding Permit No SW8 070226MOD dated September 16 2010 for the construction of the subject protect This permit shall be effective from the date of issuance until March 16 2017 and shall be subject to the conditions and limitations as specified therein Please pay special attention to the Operation and Maintenance requirements in this permit Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems If any parts requirements or limitations contained in this permit are unacceptable you have the right to request an adtudicatory, hearing upon written request within thirty (30) days following receipt of this permit This request must be in the form of a written petition conforming to Chapter 150E of the North Carolina General Statutes and filed with the Office of Administrative Hearings P O Drawer 27447 Raleigh NC 27611 7447 Unless such demands are made this permit shall be final and binding If you have any questions or need additional information concerning this matter please contact Chris Baker or me at (910) 796 7215 Sincerely �d orgette cott Stormwater Supervisor Division of Water Quality GDS/csb S\WQS\STORMWATER\PERMIT\070226MOD sep10 cc James Holland P E The Clark Group Pender County Building Inspections Wilmington Regional Office Central Files Wilmington Regional Office 127 Cardinal Drive Extension Wilmington North Carolina 28405 One NorthCarolina Phone 910 796 72151 FAX 910 350 20041 Customer Service 1-877-623 6748 a � Internety navaterqualty org /V(7h1.r17LLt1 State Stormwater Management Systems Permit No SW8 070226MOD STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY COMMERCIAL DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143 General Statutes of North Carolina as amended and other applicable Laws Rules and Regulations PERMISSION IS HEREBY GRANTED TO Cypress Coex LLC Cypress Station 14985 US Hwy 17 Hampstead Pender County FOR THE construction operation and maintenance of 2 wet detention ponds in compliance with the provisions of 15A NCAC 2H 1000 and Session Law 2008 211 (hereafter collectively referred to as the stormwater rules ) the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit This permit shall be effective from the date of issuance until March 16 2017 and shall be subject to the following specified conditions and limitations I DESIGN STANDARDS 1 This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data 2 This stormwater system has been approved for the management of stormwater runoff as described in Section 17 on page 3 of this permit The stormwater control has been designed to handle the runoff from 278 110 square feet of impervious area 3 A 50 wide vegetative buffer must be provided adjacent impounded structures streams rivers and tidal waters 4 The tract will be limited to the amount of built upon area indicated on page 3 of this permit and per approved plans 5 All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements The final plats for the project will be recorded showing all such required easements in accordance with the approved plans 6 The runoff from all built upon area within the permitted drainage area(s) of this project must be directed into the permitted stormwater control system Page 2 of 8 State Stormwater Management Systems Permit No SW8 070226MOD 7 The following design criteria have been provided in the wet detention ponds and must be maintained at design condition Basin A Basin B a Drainage Area ac (1) Onsite ft2 (2) Offsite ft2 288 125 397 None 772 336 241 None b Total Impervious Surfaces ft2 (1) Onsite ft2 (2) Offsite ft2 (3) Parcel ft2 (4) Parcel 2 ft2 (5) Parcel 3 ft2 69 764 69 764 None 208 346 208 346 None 61 870 49 417 38 014 c Pond Depth feet 5 3 d Design Storm in 1 5 1 5 e Permanent Pool Elev FMSL 44 44 f Perm Pool Surface Area ft2 9 631 15 306 g Permitted Storage Volume ft 14 458 30 881 h Temporary Storage Elev FMSL 4538 4567 i Pre dev 1 yr 24 hr discharge rate cfs N/A 1424 I Controlling Orifice 0 pipe 1 5 2 k Orifice flowrate cfs N/A 007 1 Permitted Forebay Volume ft 11 132 10 465 m Max fountain horsepower 1/8 1/6 m TSS removal efficiency % 90 g0 n Receiving Stream / River Basin Harrisons Creek/Cape Fear o Stream Index Number 18 74-49 p Classification of Water Body C SW II SCHEDULE OF COMPLIANCE The stormwater management system shall be constructed in its entirety vegetated and operational for its Intended use prior to the construction of any built upon surface During construction erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately The permittee shall at all time provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency The approved Operation and Maintenance Plan must be followed in Its entirety and maintenance must occur at the scheduled Intervals including but not limited to a Semiannual scheduled Inspections (every 6 months) b Sediment removal c Mowing and re vegetation of slopes and the vegetated filter d Immediate repair of eroded areas e Maintenance of all slopes in accordance with approved plans and specifications f Debris removal and unclogging of outlet structure orifice device flow spreader catch basins and piping g Access to the outlet structure must be available at all times Page 3 of 8 State Stormwater Management Systems Permit No SW8 070226MOD 4 Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ The records will indicate the date activity name of person performing the work and what actions were taken Decorative spray fountains will be allowed in the stormwater treatment system subject to the following criteria a The fountain must draw its water from less than 2 below the permanent pool surface b Separated units where the nozzle pump and intake are connected by tubing may be used only if they draw water from the surface in the deepest part of the pond c The falling water from the fountain must be centered in the pond away from the shoreline d The maximum horsepower for a fountain in this pond A and B are 1/8 and 1/6 horsepower respectively The facilities shall be constructed as shown on the approved plans This permit shall become void unless the facilities are constructed in accordance with the conditions of this permit the approved plans and specifications and other supporting data Upon completion of construction prior to issuance of a Certificate of Occupancy and prior to operation of this permitted facility a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit the approved plans and specifications and other supporting documentation Any deviations from the approved plans and specifications must be noted on the Certification A modification may be required for those deviations If the stormwater system was used as an Erosion Control device it must be restored to design condition prior to operation as a stormwater treatment device and prior to occupancy of the facility Access to the stormwater facilities for inspection and maintenance shall be maintained via appropriate recorded easements at all times 10 The permittee shall submit to the Director and shall have received approval for revised plans specifications and calculations prior to construction for any modification to the approved plans including but not limited to those listed below a Any revision to any item shown on the approved plans including the stormwater management measures built upon area details etc b Project name change c Transfer of ownership d Redesign or addition to the approved amount of built upon area or to the drainage area e Further development subdivision acquisition lease or sale of any all or part of the project area The project area is defined as all property owned by the permittee for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought f Filling in altering or piping of any vegetative conveyance shown on the approved plan Page 4 of 8 State Stormwater Management Systems Permit No SW8 070226MOD 11 Prior to the construction of any permitted future areas shown on the approved plans the permittee shall submit final site layout and grading plans to the Division for approval 12 A copy of the approved plans and specifications shall be maintained on file by the Permittee at all times 13 The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit Within the time frame specified in the notice the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made III GENERAL CONDITIONS This permit is not transferable to any person or entity except after notice to and approval by the Director In the event of a change of ownership or a name change the permittee must submit a completed Name/Ownership Change Form signed by both parties to the Division of Water Quality accompanied by the supporting documentation as listed on page 2 of the form The approval of this request will be considered on its merits and may or may not be approved 2 The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request Neither the sale of the project nor the transfer of common area to a third party constitutes an approved transfer of the stormwater permit 3 Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality in accordance with North Carolina General Statute 143 215 6A to 143 215 6C 4 The issuance of this permit does not preclude the Permittee from complying with any and all statutes rules regulations or ordinances which may be imposed by other government agencies (local state and federal) having jurisdiction 5 In the event that the facilities fail to perform satisfactorily including the creation of nuisance conditions the Permittee shall take immediate corrective action including those as may be required by this Division such as the construction of additional or replacement stormwater management systems 6 The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility 7 The permit remains in force and effect until modified revoked terminated or renewed The permit may be modified revoked and reissued or terminated for cause The filing of a request for a permit modification revocation and re issuance or termination does not stay any permit condition 8 Unless specified elsewhere permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual 9 Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit Page 5 of 8 State Stormwater Management Systems Permit No SW8 070226MOD 10 The permittee shall notify the Division of any name ownership or mailing address changes at least 30 days prior to making such changes 11 The permittee shall submit a permit renewal request at least 180 days prior to the expiration date of this permit The renewal request must include the appropriate documentation and the processing fee Permit issued this the 16th day of September 2010 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION ror uoieen z�iumns uirector Division or Water Quality By Authority of the Environmental Management Commission Page 6 of 8 State Stormwater Management Systems Permit No SW8 070226MOD Cypress Statin Stormwater Permit No SW8 070226MOD Pender County Designers Certification I as a duly registered in the State of North Carolina having been authorized to observe (periodically/ weekly/ full time) the construction of the protect (Project) for (Project Owner) hereby state that to the best of my abilities due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications The checklist of items on page 2 of this form is included in the Certification Noted deviations from approved plans and specifications Signature Registration Number Date SEAL Page 7 of 8 State Stormwater Management Systems Permit No SW8 070226MOD Certification Requirements 1 The drainage area to the system contains approximately the permitted acreage 2 The drainage area to the system contains no more than the permitted amount of built upon area 3 All the built upon area associated with the project is graded such that the runoff drains to the system 4 All roof drains are located such that the runoff is directed into the system 5 The outlet structure elevations are per the approved plan 6 The outlet structure is located per the approved plans 7 Trash rack is provided on the outlet structure 8 All slopes are grassed with permanent vegetation 9 Vegetated slopes are no steeper than 3 1 10 The inlets are located per the approved plans and do not cause short circuiting of the system 11 The permitted amounts of surface area and/or volume have been provided 12 Required drawdown devices are correctly sized and located per the approved plans 13 All required design depths are provided 14 All required parts of the system are provided such as a vegetated shelf and a forebay 15 The required system dimensions are provided per the approved plans 16 All components of the stormwater BMP are located in either recorded common areas or recorded easements cc NCDENR DWQ Regional Office Pender County Building Inspections Page 8 of 8 DWQ USE ONLY Date Received Fee Paid Permit Number �/ SD ao Applicable Rules ❑ Coastal SW -1995 ❑ Coastal SW - 2008 ❑ Ph II Post Construction (select all that apply) ❑ Non Coastal SW HQW/ORW Waters ❑ Universal Stormwater Management Plan ❑ Other WQ Mgmt Plan State of North Carolina Department of Environment and Natural Resources Division of Water Quality DECEIVED STORMWATER MANAGEMENT PERMIT APPLICAT N F,8N 2010 This form may be photocopied for use as an original I GENERAL INFORMATION LBY 1 Project Name (subdivision facility or establishment name should be consistent with project name on plans specifications letters operation and maintenance agreements etc ) CYPRESS STATION 2 Location of Project (street address) City Hampstead County Pender Zip 28443 3 Directions to project (from nearest major intersection) From intersection of NC Hwy 210 W & US Hwy 17 proceed north on US 17 for 0 40 to the project site on the 4 Latitude 34 22 15 30 N Longitude 77 42 29 87 W of the main entrance to the project II PERMIT INFORMATION 1 a Specify whether project is (check one) ❑New ®Modification b If this application is being submitted as the result of a modification to an existing permit list the existing permit numberSW8 070226 its issue date (if known)3/16/07 and the status of construction ❑Not Started ®Partially Completed ❑ Completed provide a designer s certification 2 Specify the type of project (check one) ❑Low Density ®High Density []Drains to an Offsite Stormwater System ❑Other 3 If this application is being submitted as the result of a previously returned application or a letter from DWQ requesting a state stormwater management permit application list the stormwater project number if assigned and the previous name of the project if different than currently proposed 4 a Additional Project Requirements (check applicable blanks information on required state permits can be obtamed by contacting the Customer Service Center at 1 877 623-6748) ❑LAMA Major ®Sedimentation/Erosion Control ac of Disturbed Area ❑NPDES Industrial Stormwater ❑404/401 Permit Proposed Impacts b If any of these permits have already been acquired please provide the Project Name Project/Permit Number issue date and the type of each permit Form SWU 101 Version07July2009 Page I of 4 III CONTACT INFORMATION 1 a Print Applicant / Signing Official s name and title (specifically the developer property owner lessee designated government official individual etc who owns theyro�ect) Applicant/Organization Cypress Coex, LLC Signing Official & Tale Wright Holman, Managing Member b Contact information for person listed in item la above Street Address 7036 Wrightsville Ave Suite 101 City Wilmington State NC Zip 28403 Mailing Address (if applicable) Same City State Phone (910 ) 256-4209 Fax Email wrrght h@hotmad com Zip Please check the appropriate box The applicant listed above is ® The property owner (Skip to Contact Information item 3a) ❑ Lessee (Attach a copy of the lease agreement and complete Contact Information item 2a and 2b below) ❑ Purchaser (Attach a copy of the pending sales agreement and complete Contact Information item 2a and 2b below) ❑ Developer (Complete Contact Information item 2a and 2b below ) 2 a Print Property Owner s name and title below if you are the lessee purchaser or developer (This is the person who owns the property that the project is located on) Property Owner/Organization Cypress Coex, LLC Signing Official & Title Wright Holman, Managing Member b Contact information for person listed in item 2a above Street Address 7036 Wrightsville Ave Suite 101 City Wilmington State NC Zip 28403 Mailing Address (if applicable) City Phone Email State Zip Fax 3 a (Optional) Print the name and title of another contact such as the project s cbRs�'trf$on'suPeW1 person who can answer questions about the project I JUN 9 Other Contact Person/Organization L ZO)� Signing Official & Title b Contact information for person listed in item 3a above Mailing Address City Phone Email State Fax Zip 4 Local jurisdiction for building permits Pender County Point of Contact Mike Harrison Phone # (910 ) 2705009 Form SWU 101 Version 07July2009 Page 2 of 6 IV PROJECT INFORMATION 1 In the space provided below briefly summarize how the stormwater runoff will be treated Storm water runoff will be conveyed from guttered buildings to roads with curb and gutter to catch basins which will convey the water through pipes to the storm water wet pond 2 a If clamung vested rights identify the supporting documents provided and the date they were approved ❑ Approval of a Site Specific Development Plan or PUD Approval Date ❑ Valid Budding Permit Issued Date ❑ Other Date b Identify the regulation(s) the project has been designed in accordance with ❑ Coastal SW -1995 ❑ Ph II - Post Construction 3 Stormwater runoff from this project drains to the Cie Fear River basin 4 Total Property Area 14 60 acres 5 Total Coastal Wetlands Area 0 acres 6 Total Surface Water Area 133 acres 7 Total Property Area (4) - Total Coastal Wetlands Area (5) - Total Surface Water Area (6) = Total Project Area 13 27 acres Total project area shall be calculated to exclude the following the normal pool of impounded structures the area between the banks of streams and rivers the area below the Normal High Water (N� line or Mean High Water (MHW) line and coastal wetlands landward from the NHW (or MHM line The resultant project area is used to calculate overall percent built upon area (BUA) Non coastal wetlands landward of the NHW (or MHW) line may be included in the total project area 8 Project percent of impervious area (Total Impervious Area / Total Project Area) X 100 = 4811 % 9 How many drainage areas does the project have?2 (For high density count 1 for each proposed engineered stormwater BMP For low density and other projects use 1 for the whole property area) 10 Complete the following information for each drainage area identified in Project Information item 9 If there are more than four drainage areas in the project attach an additional sheet with the information for each area provided in the same format as below Pond A Pot 4 (` Basin Information Drainage Area 1 Drainage Area 2 Drainage Area _ Drainage Area _ Receiving Stream Name Harrison creek Harrison Creek Stream Class C Sw C Sw Stream Index Number 18-74-49 18 74-49 Total Drainage Area (so 125 397 4 336 241 On site Drainage Area (so 125 397 4 336 241 Off site Drainage Area (sf) 0 1 0 Proposed Impervious Area (so 9 764 3 208 346 / Impervious Area total 556 6196 Im ervious' Surface Area Drama e Area 1 Drainage Area 2 Drainage Area _ Drainage Area _ On site Buddmgs/Lots (so 29 220 31110 On site Streets (so 31040 33 672 On site Parkmg (so 8 220 8 9 945 On site Sidewalks (so 1 283 5 1 792 JUN 2 9 2010 Other on site (so 0 0 Future (so 0 0 0 131927 Existing BUA (so 0 0 Total (so 69 764 3 208 346 Stream Class and Index Number can be determined at http //h2o cur state nc us/btms/reports/reportsWB html Impervious area is defined as the built upon area including but not limited to buildings roads parking areas sidewalks gravel areas etc Report only that amount of existing BUA that will remain after development Do not report any existing BUA that is to be removed and which will be replaced by new BUA Form SWU 101 Version 07July2009 Page 3 of 6 11 How was the off site impervious area listed above determined? Provide documentation N/ A Pro iects in Union County Contact DWQ Central Office staff to check if the project is located within a Threatened & Endangered Species watershed that maybe subject to more stringent stormwater requirements as per NCAC 02B 0600 V SUPPLEMENT AND O&M FORMS The applicable state stormwater management permit supplement and operation and maintenance (O&M) forms must be submitted for each BMP specified for this project The latest versions of the forms can be downloaded from http //h2o enr state nc us/su/bmp_forms htm VI SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ) A complete package includes all of the items listed below A detailed application instruction sheet and BMP checklists are available from http / /h2o enr state nc us/su/bmp forms htm The complete application package should be submitted to the appropriate DWQ Office (The appropriate office may be found by locating project on the interactive online map at http //h2o enr state nc us/su/msi_maps htm ) Please indicate that the following required information have been provided by initialing in the space provided for each item All original documents MUST be signed and initialed in blue ink Download the latest versions for each submitted application package from http //h2o enr state nc us/sic/bmp_forms htm 1 Original and one copy of the Stormwater Management Permit Application Form 2 Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants Form (if required as per Part VII below) 3 Onginal of the applicable Supplement Form(s) (sealed, signed and dated) and O&M agreement(s) for each BMP 4 Permit application processing fee of $505 payable to NCDENR (For an Express review refer to http //www envhelp org/pages/onestopexpress html for information on the Express program and the associated fees Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required application meeting) 5 A detailed narrative (one to two pages) describing the stormwater treatment/managementfor the project This is required in addition to the brief summary provided in the Project Information item 1 6 A USGS map identifying the site location If the receiving stream is reported as class SA or the receiving stream drams to class SA waters within th mile of the site boundary include the 1/2 mile radius on the map 7 Sealed signed and dated calculations 8 Two sets of plans folded to 8 5 x 14 (sealed signed & dated) including a Development/Project name b Engineer and firm c Location map with named streets and NCSR number:77 d Legend 2010e North arrow f Scale g Revision number and datesh Identify all surface waters on the plans by delineating the normal a of impounded structures the banks of streams and rivers the MHW or NHW line of tidal waters and any coastal wetlands landward of the MHW or NHW lines Delineate the vegetated buffer landward from the normal pool elevation of impounded structures the banks of streams or rivers and the MHW (or NHW) of tidal waters i Dimensioned property/project boundary with bearings & distances I Site Layout with all BUA identified and dimensioned k Existing contours proposed contours spot elevations finished floor elevations I Details of roads drainage features collection systems and stormwater control measures in Wetlands delineated or a note on the plans that none exist (Must be delineated by a qualified person Provide documentation of qualifications and identify the person who made the determination on the plans n Existing drainage (including off site) drainage easements pipe sizes runoff calculations o Drainage areas delineated (included in the main set of plans not as a separate document) p Vegetated buffers (where required) Initials JwA JW4 Jc✓l1 JW4 JW4 Jwq Jwt( Form SWU 101 Version 07July2009 Page 4 of 6 4 9 Copy of any applicable soils report with the associated SHWT elevations (Please identify VIA elevations in addition to depths) as well as a map of the boring locations with the existing elevations and bormg logs Include an 8 5 x11 copy of the NRCS County Sods map with the project area clearly delineated For projects with infiltration BMPs the report should also include the soil type expected infiltration rate and the method of determining the infiltration rate (Infiltration Devices submitted to WiRO Schedule a site msit for DWQ to verify the SHWT pnor to submittal (910) 796 7378 ) 10 A copy of the most current property deed Deed book 3665 Page No 255 & 259 Jwt( 11 For corporations and Imuted liability corporations (LLC) Provide documentation from the NC Jw8 Secretary of State or other official documentation which supports the btles and positions held by the persons listed in Contact Information item 1a 2a and/or 3a per NCAC 2H 1003(e) The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State otherwise the apphcabon will be returned http / /www secretary state nc us/Corporations/CSearch aspx VII DEED RESTRICTIONS AND PROTECTIVE COVENANTS For all subdivisions outparcels and future development the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot If lot sizes vary significantly or the proposed BUA allocations vary a table listing each lot number lot size and the allowable built upon area must be provided as an attachment to the completed and notarized deed restriction form The appropriate deed restrictions and protective covenants forms can be downloaded from htto //h2o enr state nc us/su/bmp forms htm#deed restrictions Download the latest versions for each submittal In the instances where the applicant is different than the property owner it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded By the notarized signature(s) below the permit holder(s) certify that the recorded property restrictions and protective covenants for this project if required shall include all the items required in the permit and listed on the forms available on the website that the covenants will be binding on all parties and persons clairrung under them that they will run with the land that the required covenants cannot be changed or deleted without concurrence from the NC DWQ and that they will be recorded prior to the sale of any lot VIII CONSULTANT INFORMATION AND AUTHORIZATION Applicant Complete this section if you wish to designate authority to another individual and/or firm (such as a consulting engineer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional information) Consulting Engineer Michael L Tackett, PLS Consulting Firm The Clark Group Mailing Address City Wilmmgton Phone (910 ) 6023900 Email mtackett@clarkgroup us State NC Zip 28404 Fax (910 ) 6023975 IX PROPERTY OWNER AUTHORIZATION (if Contact infonnahon item 2 has been filled out complete this section) I (print or type name of person listed in Contact Informahon item 2a) Wright Holman certify that I own the property identified in this permit application and thus give permission to (print or type name of person listed in Contact Informahon item la) Wnght Holman with (print or type name of organization listed in Contact Informahon item 1b) Citpress Coex, LLC to develop the project as currently proposed A copy of the lease agreement or pending property sales contract has been provided with the submittal which indicates the party responsible for the operation and maintenance of the stormwater system RECEIVED JUN 2 9 2010 Ry Form SWU 101 Version 07July2009 Page 5 of 6 As the legal property owner I acknowledge understand and agree by my signature below that if my designated agent (entity listed in Contact Information item 1) dissolves their company and/or cancels or defaults on their lease agreement or pending sale responsibility for compliance with the DWQ Stormwater permit reverts back to me the property owner As the property owner it is my responsibility to notify DWQ immediately and submit a completed Name/Ownership Change Form within 30 days otherwise I will be operating a stormwater treatment facility without a valid permit I understand that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statue 143-2151 and may result in appropriate enforcement action including the assessment of civil penalties of up tip $25 900 Fier y p rsuant to NCGS 143 215 6 Signature Date t, I 1 I the State of ,t4 ftA County of /YF,ttJ 94NOVEa- do hereby certify that��Fir{ WMA� personally appeared Ll before me this I & day of f. 7-010 and acknowledge the due execution of the application for a stormwater permit Witness my hand and official seal SEA My commission expires / -&-0013 X APPLICANTS CERTIFICATION I (print or type name of person listed in Contact Information item 2) Wright Holman certify that the information included on this permit application form is to the best of my knowledge correct and that the project will be constructed in conformance with the approved plans that the required deed restrictions and protective covenants will be recorded and tl ert'tl proposed project complies with the requirements of the applicable stormw ter under 5A C C 100 SL 2006 246 (Ph 11- Post Construchon) or SL 2008-211 SignaturDate I a Notary Public for the State of NIO � LJA: County of NL !d :JA401/E,& , do hereb certify that J Wu GIA'f" 4/M f: N personally appeared �i before in � de this ay of O and acknowledge the due exec on f the application for a stormwater permit Witness my hand and official sea'h<zJ—VaA1 Ltn c�A SEAL My commission expires Zo -Zo 1-3 RECEIVED JUN 2 9 2010 Form SWU 101 Version 07July2009 Page 6 of 6 w F"A ..� r NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H Sullins Dee Freeman Governor Director Secretary STATE STORMWATER PERMIT NAME/OWNERSHIP CHANGE FORM I CURRENT PERMIT INFORMATION 1 Stormwater Management Permit Number sw A O ?022 6 2 Project Name S 3 Current Permit Holder s Company Name/Organization Cypress CWJe- %wnL%?es L4C 4 Signing Officials Name Immy f/fir n5r%r , Title Oisna/,?$ Ael!? (person leg, Ily respgnsib a for permit) 5 Mailing Address City tkiymps�eoo' State-,A),I— Zip 23 6 Phone /0 ) ZZq tf.?k% Fax 11 PROPOSED PERMITTEE / OWNER / PROJECT / ADDRESS INFORMATION This request is for (please check all that apply) ® Name change of the owner (Please complete Items 1 2 and 3 below) Name change of project (Please complete Item 5 below) ® Change in ownership of the property/company (Please complete Items 1 ❑ Mailing address / phone number change (Please complete Item 4 below) ❑ Other (please explain) 2 3 and 4 below) 1 Proposed permittees company name/organization C AEfSs (20ex , LLC 2 Proposed permittees signing officials name-A&C,�Innq , /9 3 Proposed permittee s Title Y)0 091�: 0!o— Me r 4 Mailing Address 7V 3 Wr, test/, I,11'se City O m, f 1p r�- State J✓✓�Zlp z 43 yD 3 Phone 910 ) 42 Sb -- yzo 9 Fax ( ) 5 New Project Name to be placed on permit ��r�A4, 5��7aY-� Please check the appropriate box The proposed permittee listed above is ❑ HOA or POA (Attach a copy of the deed transferring ownership of all common areas Print Name of HOA or POA in #1 above and provide name of HOA(POA) president in #2 above) The property owner ❑ Lessee (Attach a copy of the lease agreement and complete Property Own ion on page 4) 1 g 1%%" ❑ Purchaser (Attach a copy of the pending sales agreement and compl b Prop�CJwner Information on page 4) \\ ❑ Developer (Complete Property Owner Information on page 4) VC SSW N/O Change Rev16Nov2009 Page 1 of 4 III REQUIRED ITEMS This application package will not be accepted by the Division of Water Quality unless all of the applicable required items listed below are included with the submittal This completed and signed form Legal documentation of the transfer of ownership (For Permit Transfers Complete Current Permittee and Proposed Permittee Sections) A copy of the recorded deed restrictions if required by the permit The designers certification if required by the permit and if not already submitted to DWQ If the Proposed Permittee is a corporation LLC or General Partnership provide documentation from the Secretary of State office which supports the named president vice president member manager or General Partner The $40 00 processing fee If this is an initial transfer from the original permittee to the property owner or other responsible party such as an HOA the processing fee is not required Subsequent ownership transfers will require the $40 00 processing fee IV CURRENT PERMITTEE S CERTIFICATION Please check one of the following statements FCheck here if the Current Owner is only changing the owner name company name or project ame or the mailing address and will retain ownership of the permit Y LJr-), 1�ojma ,or• CrAr<cs Coex U4he current owner hereby notify the Division of Water Ouality that I am changin y name or company name and/or I am changing my mailing address and/or I am changing the name of the permitted project I further attest that this application for a name/ownership change is accurate and complete to the best of my knowledge I understand that if all required parts of this application are not completed and that if all required supporting information and attachments as outlined above are not included this application package will be returned as incomplete ❑ Check here if Current Owner Is transferring (selling) the property to a new owner and will not retain ownership of the permit I the current owner am submitting this application for a transfer of ownership for permit # I hereby notify DWQ of the sale or other legal transfer of the stormwater system associated with this permit I further acknowledge and attest that I have transmitted a copy of the most recent permit a copy of the Designers Certification a copy of the DWQ approved plans and/or approved as built plans a copy of the approved Operation and Maintenance agreement and copies of past maintenance records to the Proposed Permittee named in Sections II and V of this form at the mailing address listed in Section 11 of this form I further attest that I assign all rights and obligations as permittee to the Proposed Permittee named in Section V of this form I understand that this transfer of ownership cannot be approved by the Division of Water Quality unless and until the facility is in compliance with the permit and the Proposed Permittee signs this form I understand that in the event the facility is not in compliance or the Proposed Permittee does not sign this form the responsibility to bring the facility into compliance and to comply with the terms and conditions of the pe it remai svw me until such time as the Proposed Permittee signs this form and the Dw n app ve it Signature //J�- Date L I %72A fJ l— t }IJ,I E2SorJ a Notary Public for the State of % day of County of NEW -HAt-IZVEK� do hereby certify that personally appeared before me this the 20 10 and acknowledge the due forgoing instrument Witness my hand and official seal Notary Signature SSW N/O Change Rev16Nov2009 Page 2 of 4 V PROPOSED PERMITTEE CERTIFICATION (This section must be completed by the Proposed Permittee for all transfers of ownership) awi,Ak A)mo n t1/r-- r ag refs 40! ue hereby notify the Division of Water Quality that I have acquired through sale leastf or legal transfer the responsibility for constructing and/or operating and maintaining the permitted stormwater management system I have examined the permit and inspected the permitted facility and agree to assume the rights and liabilities contained in the permit and to comply with the terms and conditions of the permit I attest that I have reviewed this application for an ownership change and it is accurate and complete to the best of my knowledge I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included this application package will be returned as incomplete I further acknowledge and attest that in the event the required facility inspection reveals that the project is not in compliance with the permit I understand this transfer of ownership will not be approved until the project is brought into compliance I acknowledge and attest that I have received a copy of the most recent permit a copy of the Designers Certification a copy of the DWQ approved plans and/or approved as built plans a copy of the approved Operation and Maintenance agreement and copies of past maintenance records from the previous permittee I further acknowledge and agree that I will construct and/or operate and intain the system per the requirements listed in the permit and in the OpIrat on and M I to an gr ement Signature"" I f�� �1Gc3 /lam 1+�i p J " a Notary Pu he for the State of NOO-4 OA(Cobt44 County of NEtJ �y++`io��- do hereby certify that (,c)wc�Azk �/tK4&J personally appeared before me this the 41t' day of � Lu le 2010 and acknowledge the due execution of the forgoing instrument Witness my hand and official seal i'�/%QiYI[ta C��Lne r-- (Notary Seal) Notary Signature Additional copies of the original permit and the approved Operation and Maintenance plan can be obtained from the appropriate Regional Office of the Division of Water Quality This completed form including all supporting documents and processing fee should be sent to the appropriate Regional Office of the North Carolina Department of Environment and Natural Resources Division of Water Quality as shown on the attached map Please note that if the Proposed Permittee listed above is not the property owner the property owner must complete and sign page 4 of this document Both the lessee / developer and the property owner will appear on the permit as permIttees RECEIVED JUN 2 9 2010 gv SSW N/O Change Rev16Nov2009 Page 3 of 4 VI PROPERTY OWNER CONTACT INFORMATION AND CERTIFICATION If the Proposed Permittee listed in Sections 11 and V of this form is not the Property Owner the Property Owner must provide his/her Contact Information below and sign this form Printed Name (jj- "t Mvy10YAr111 Organization CYOrrsS CpP_>C L.L C- Title within the Organization ! as /TeC Street Address City 4) jvni ng 4o✓^ V State IJ Zip 'Z 19 �/O 3 Mailing Address City (if different from street address) State Phone 9/O - Z S'6 - 4 ZD 9 Fax WN," Zip I certify that I own the property identified in this permit transfer document and have given permission to the Proposed Permittee listed in Sections II and V to develop lease or purchase the property A copy of the lease agreement or pending property sales contract has been provided with the submittal which indicates the party responsible for the construction and/or operation and maintenance of the stormwater system As the legal property owner I acknowledge understand and agree by my signature below that I will appear as a permittee along with the lessee/developer and that if the designated Proposed Permittee dissolves their company and/or cancels or defaults on their lease agreement or pending sales contract responsibility for compliance with the DWQ Stormwater permit reverts back to me the property owner As the property owner it is my responsibility to notify DWQ by submitting a completed Name/Ownership Change Form within 30 days of procuring a developer lessee or purchaser for the property I understand that failure to operate and maintain the stormwater treatment facility in accordance with the permit is a violation of NC General Statue 143 215 1 and may result in appropriate enforcement action including sessment of civil penalties of up to $25 000 per day pursuant to NCGSI 1 (Y-,215 6 A f Signature of the property owner day of ;— Oate LO 1i 1 a Notary Public for the State of County of /V Et,J PAt1 o 05L do hereby certify that personally appeared before me this the 20 10 and acknowledge the due execution of the forgoing instrument Witness my hand and official seal otary Signature RECEIVED JUN 2 9 2010 (Notary Seal) , SSW N/O Change Revl6Nov2009 Page 4 of 4 k State Stormwater Management Systems Permit No SW8 070226MOD Cypress Statm Stormwater Permit No SW8 070226MOD Pander Countv Designers Certification 1 JAws W rlecc. 0> as a duly registered Whotu.,#. rv(vAgvr, in the State of North Carolina having been authorized to observe (ReIlBdtI;Pliy/ weekly/ full time) the construction of the protect CIPAW Sr&lpq (Protect) for Gist• Coat u,c (Protect Owner) hereby state that to the best of my abilities due care and diligence was used in the observation of the protect construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications The checklist of items on page 2 of this form is included in the Certification Noted deviations from approved plans and specifications Signature JAµEs &j Registration Number 0I39ib Date X, Zen Pone 7 of 91 k State Stormwater Management Systems Permit No SW8 070226MOD Certification Requirements 1 The drainage area to the system contains approximately the permitted VV acreage 2 The drainage area to the system contains no more than the permitted (J amount of built upon area 3 All the built upon area associated with the project is graded such that the runoff drains to the system 4 All roof drams are located such that the runoff is directed into the system 5 The outlet structure elevations are per the approved plan 6 The outlet structure is located per the approved plans f 7 Trash rack is provided on the outlet structure V 11 -8 All slopes are grassed with permanent vegetation (/ 9 Vegetated slopes are no steepeLthan-3-t _ WI 10 The inlets are located per the approved plans and do not cause short circuiting of the system The permitted amounts of surface area and/or volume have been provided � 12 Required drawdown devices are correctly sized and located per the approved plans marl 13 All required design depths are provided ( Ad 14 All required parts of the system are provided such as a vegetated shelf and a forebay ,444 15 The required system dimensions are provided per the approved plans � 16 All components of the stormwater BMP are located in either recorded common areas or recorded easements cc NCDENR DWQ Regional Office Pander County Building Inspections Panes R of R State Stormwater Management Systems Permit No SW8 070226MOD Cypress Stalin Stormwater Permit No SW8 070226MOD Pender Countv Designers Certification I ,1A4[FS w .416UA�,o as a duly registered Veo&_w wy_ in the State of North Carolina having been authorized to observe ( o t y/ weekly/ full time) the construction of the protect CCIIIe5S' S7¢Poy - D/CAiN4Gc A26A /i auu (Protect) for Cc/P2ess 69 y_ LLC (Protect Owner) hereby state that to the best of my abilities due care and diligence was used in the observation of the protect construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications The checklist of items on page 2 of this form is included in the Certification Noted deviations from approved plans and specifications Signature Registration Number 033�/6 Date M44y 2, p 20� i LJU VFD SEAL C ARO(���% �rQ oFESS/0* 4,SEAL P hw 14� �f/2 (PJ/ /fririnwa �Fc� SUN 0 12�11 Dnno 7 of A State Stormwater Management Systems Permit No SW8 070226MOD Certification Requirements -pR ,NAGE 8 p�JL'17 JW11 1 The drainage area to the system contains approximately the permitted acreage Jw/( 2 The drainage area to the system contains no more than the permitted amount of built upon area J&J9 3 All the built upon area associated with the protect is graded such that the runoff drains to the system jto�L_4 All roof drains are located such that the runoff is directed into the system JW9 5 The outlet structure elevations are per the approved plan ��6 The outlet structure is located per the approved plans Jw!l 7 Trash rack is provided on the outlet structure -koll 8 All slopes are grassed with permanent vegetation 9 Veaetated slopes are, no stee eg r than 3.1 Jwl/ 10 The inlets are located per the approved plans and do not cause short circuiting of the system 11 The permitted amounts of surface area and/or volume have been provided ,A,ad 12 Required drawdown devices are correctly sized and located per the approved plans ,lW,4 13 All required design depths are provided a _14 All required parts of the system are provided such as a vegetated shelf and a forebay J,dW 15 The required system dimensions are provided per the approved plans Jw,l 16 All components of the stormwater BMP are located in either recorded common areas or recorded easements cc NCDENR DWQ Regional Office Pender County Budding Inspections pana R of R ,T- High Density Developments with Outparcels Deed Restrictions & Protective Covenances In accordance with Title 15 NCAC 2H 1000 and S L 2006 246 the Stormwater Management Regulations deed restrictions and protective covenants are required for High Density Developments with Outparcels where outparcel lots will be subdivided from the main tract and sold Deed restrictions and protective covenants are necessary to ensure that the development maintains a built upon area consistent with the design criteria used to size the stormwater control facility I_i.Wr wh+ 40)mo/n� /// acknowledge affirm and agree by my signature below that I will cause t following deed restrictions and covenants to be recorded prior to the sale of any outparcel or future development area The following covenants are intended to ensure ongoing compliance with State Stormwater Management Permit Number Su) g 070 ZZ(� as issued by the Division of Water Quality under the Stormwater Management Regulations 2 The State of North Carolina is made a beneficiary of these covenants to the extent necessary to maintain compliance with the stormwater management permit 3 These covenants are to run with the land and be binding on all persons and parties claiming under them 4 The covenants pertaining to stormwater may not be altered or rescinded without the express written consent of the State of North Carolina Division of Water Quality 5 Alteration of the drainage as shown on the approved plan may not take place without the concurrence of the Division of Water Quality 6 The maximum built upon area for the outparcel(s) shown on the approved plans is as follows Outparcel # BUA Outparcel # BUA / 6J, S 70 3 Z22 Y/ 7 These allotted amounts include any built upon area constructed within the property boundaries and that portion of the right of way between the lot Imes and the edge of the pavement Built upon area includes but is not limited to structures asphalt concrete gravel brick stone slate coquina and parking areas but does not include raised open wood decking or the water surface of swimming pools 7 The runoff from all built upon area within the outparcel or future development area must be directed into the permitted stormwater control system 8 Built upon area in excess of the permitted amount will require a permit modification 9 The connection from the outparcel s collection system into the stormwater control shall be made such that short circuiting of the system does not occur 10 For those outparcels or future development areas whose ownership is not retained by the permittee the new owner shall submit a separate offsite stormwater permit application to the Division of Water Quality and receive a permit prior to construction 11 The project and each outparcel will maintain a 30** foot wide vegetated buffer between all impervious areas and surface waters * 50 foot for projects located in the 20 coastal counties RECEIVED JUN 2 9 2010 �v Form DRPC 2 Rev 2 05Nov2009 Page t of 2 High Density Developments with Outparcels Deed Restrictions & Protective Covenances Signature —r�o a Nota� Public in the State of IVOlt h CAA.Db, J A/� County✓V of EO C.J (.yt7�1/�a✓�� do hereby certify that &A4--Al otl personally appeared before me this the day of 2010 and acknowledge the due execution of the foregoing instrument Witness my hand and official seal SEAL My Commission expires / ,& 2,013 Form DRPC 2 Rev 2 05Nov2009 Page 2 of 2 The Clark Group POST OFFICE BOX 10136 WILMlNGTON NC 28404 0136 Ito] RECD AUG 3 0 2010 LETTER OF TRANSMITTAL DATE PROJECT NO ®� ATTENTION RE C Pis - Glo✓�Tac�� horn WE ARE SENDING YOU X ATTACHED UNDER SEPARATE COVER OTHER (SPECIFY) SHIPPED VIA THE FOLLOWING NO COPIES DATE DESCRIPTION 'z :!�O THESE ITEMS ARE TRANSMITTED AS CHECKED BELOW _ FOR APPROVAL _ FOR YOUR USE _ AS REQUESTED _ FOR REVIEW/COMMENT 9 I NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor July 27 2010 Wright Holman Managing Member Cypresss Coex LLC 7036 Wrightsville Ave Suite 101 Wilmington NC 28403 Division of Water Quality Colleen H Sullins Director Subject Request for Additional information Stormwater Project No SW8 070226MOD Cypress Station Pender County Dear Mr Holman Dee Freeman Secretary The Wilmington Regional Office received and accepted a modified State Stormwater Management Permit Application for Cypress Coex on June 29 2010 A preliminary in depth review of that information has determined that the application is not complete The following information is needed to continue the stormwater review Please provide boundary lines with bearings and distances for the proposed lots 1 2 and 3 In addition to the acreage already called out on the plans add the impervious surface area to be allowed for development Please provide basic dimensions for all planed built upon area (BUA) i e the roads parking area etc shown on the plan sheet A landscape plan and/or specifications calling for the number and type of plants for the littoral shelf is required please provide 4 Inconsistencies related to the average depth were noted between the calculations provided and the wet pond supplemental form Keep in mind that changes to the plans and permit that require the wet pond to be resized (made larger) also require the wet pond to meet all current standards The only allowance is the design storm (1 in this case) for the drainage area and BUA already permitted may remain the same Please note that this request for additional information is in response to a preliminary review The requested information should be received in this Office prior to August 28 2010 or the application will be returned as incomplete The return of a project will necessitate resubmittal of all required items including the application fee If you need additional time to submit the information please mail email or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter The request must indicate the date by which you expect to submit the required information The Division is allowed 90 days from the receipt of a completed application to issue the permit Wilmington Regional Office OtlC 127 Cardinal Drive Extension Wilmington North Carolina 28405 NorthCaroltna Phone 910 796 7215 1 FAX 91035020041Customer Service 1877-623-6748 ort hUiiroli 1 Internet v rimaterquality org Wright Holman Managing Member July 27 2010 Stormwater Application No SW8 070226MOD The construction of any impervious surfaces other than a construction entrance under an approved Sedimentation Erosion Control Plan is a violation of NCGS 143 2151 and is subject to enforcement action pursuant to NCGS 143 215 6A Please reference the State assigned project number on all correspondence Any original documents that need to be revised have been sent to the engineer or agent All original documents must be returned or new originals must be provided Copies are not acceptable If you have any questions concerning this matter please feel free to call me at (910) 796 7215 or email me at chris baker@ncdenr gov Sincerely Chris Baker Environmental Engineer II GDS/csb S\WQS\STORMWATERWDDINFO\2010\070226MOD ju110 cc Michael L Tackett P L S The Clark Group Wilmington Regional Office Stormwater File Page 2 of 2 Reviewer Received Location I Rule(s) Subject (check all that apply) Symbols for completing form ✓ = Yes/OK x = No/Deficient n/a or \ or f R" 1995 Coastal (i18,9Daiq 4'2008 Coastal (tea 16A) ❑ Phase II ❑ Universal Paperwork Check for $505 (must be no older than 6 months) Q 1 O- Application form with correct/original signatures (original plus 1 copy) If Corporation or LLC also Jip� eif'rint the Info from the NCSOS o Either 1 ) The applicant is listed on the NCSOS with his/her correct title or 2 ) A notarized letter of authorization has been provided q Mob 5 `t0 col\\ J Ci-tupplements (1 original per BMP) BMP type(s) /0 0wcls r( 0011F1F�� M,"O&M with correctloriginal signatures (1 original per BMP except level spreaders/felt trips and ales) 31—Beed restrictions (If outparcel or subdividing) (original plus 1 copy) o Deed restriction template (signed and notarized) or o Proposed Declaration of Covenants and Restrictions (signed and notarized) Sods report identifying the SHWT Ct E upporting calculations signed & sealed (If necessary) � Receiving stream classification (2 )5-0 if SA or ORW also ' o SA USGS topo map with the site the receiving waters and the A mile radius shown to scale o ORW 575 ft of MHWL for Area of Environmental Concern and max BUA per rule - �C] Modifications 1 ) If built Designer's Cent f partially built Partial Cert 3 ) If not built No Cert needed Development Type (check all that apply) Lk'Residential or ❑ Commercial ❑ Deed restrictions match? &Q Subdtvision or ❑ Single Lot ❑ Deed restrictions match? High Density or ❑ Low Density ❑ Deed restrictions match? ❑ Offsite project ❑ Redevelopment ❑ Modification 67( j ro ❑ Exempt NA ❑ NCG02 (bulkhead) ❑ NCG03 (clear/grade) ❑ NCG04 (linear) Density Lwl.-� BUA calculations include common areas clubhouse sidewalks etc UP BUA % 1,G \\ -"-Matches high/low density requirement for rule and receiving stream class ❑' No obvious mathierrors Uk"If High Density Design storm correct for rule and receiving stream class t ea Plans se ned and sealed (2 sets) UJ�Tvvo sets received ❑ Layout (with proposed BUA dimensions) ❑ Grading O�Drainage area map (all HD systems & curb outlet swales) 611"Vicinity map 6J' Project Boundaries ❑ Legend ❑ Wetlands o Delineated on plans o No wetlands onsite on plans ❑ Details o Roads o Cut de sacs o Curbing o Sidewalk o BMPs/ Level spreaders/ Filter strips/ Curb outlet swales o Buildings (Apts or Condos) Offsite Projects ❑ Designe s Certification has been submitted for the Offsite BMP receiving the runoff from the project ❑ D restrictions have been recorded and a copy submitted for the Offsite BMP permit Lot size has not changed from what was approved under the Master Plan ❑ Correct lot number is referenced on the supplement form ❑ Offsite system is in compliance with its permit if known Infiltrate rojects Soils report SHWT soil type and expected infiltration rate are provided ❑ DWO has conducted a site visit? Date Wet Ponds Permanent Pool Meets One of the Following ❑ Is located no lower than 6 below the estimated SHWT ❑ Incoming groundwater is quantified and evaluated AND Storage volume verified AND Outlet evaluated for free drainage to the receiving waters under SHWT conditions Decision (check one) ❑ Complete Return file to admin (Jo Casmer) to log in (Stamped in received date = BIMS date) ❑ Slightly incomplete E mail consultant request information to be returned within one business day (24 hours after request Info requests on Friday allow a return on the following business day) If info not returned issue an application return letter and give everything to admin (Add info received date = BIMS date) ❑ Substantially incomplete Issue an application return letter and give everything to admin Q "O,&ed ul 20 -31 (oo y 3co 3 Q �rPo`ae 1. 17 hl save. 331o3 ay 3 CN Aw��) �aH't1ST roi Spac��'.aa � A� �v�cj�vmr /pTSS 0}p go"Io CJ ,�6tl �04\0 3q o 0 38 0 o NE )� i Q m S(-v y0 2s 39 Oo ) WD lE-DE516 TOivJ (0 } vE ^(11) 1 Sl�l� eiC> �ha54W'�- •urAd 0.v4""t"j-�\calC REC'n JAL 0 9 2010 The Clark Group POST OFFICE BOX 10136 WILMINGTON NC 28404 0136 Ito] LETTER OF TRANSMITTAL DATE 7/5/,/ PROJECT N O Og ATTENTION RE L' <SS �`ta O✓L WE ARE SENDING YOU X ATTACHED UNDER SEPARATE COVER OTHER (SPECIFY) SHIPPED VIA THE FOLLOWING NO COPIES DATE DESCRIPTION Z 6e4) % TIIO eu sad see Swm I, 2, 9 R io io ( 71`d /o Sco�nel1 h ,z �6,k Lae ce THESE ITEMS ARE TRANSMITTED AS CHECKED BELOW FOR APPROVAL _ FOR YOUR USE iOAS REQUESTED _Ki OR COPY TO FILE SIGNATURE /n l Needham Environmental Inc RobertN Needham PWS 9100 Charlestowne Rd SE Wmnabow NC 28479 Office/Fax (910)371 6082 needhambud@ec rr corn Mike Tackett The Clark Group 5000 Blue Clay Rd Castle Hayne NC 28429 Tom Gulley NCLSS#1256 P O Box 960 Wilmington NC 28402 Office/Fax (910)795 0319 tgulley@gmad com July 8 2010 RE Seasonal High Water Table and infiltration Rate Determination for Cypress Station Pender County North Carolina Dear Mike Today i performed a seasonal high water table determination adjacent to an existing stormwater pond for the potential expansion of that pond The site is adjacent to Pansy Lane in Hampstead and is part of the Cypress Station Project The boring was made approximately 20 due south of the power pole located near the northern edge of the existing pond and along the northeastern property line A stake with blue ribbon and labeled X3 was placed at the boring location Below is the detailed soil profile description with an estimated seasonal high water table of 96 below existing grade Location Horizon Depth Color Texture Structure Notes/Mottles X3 Fill 020 2 5Y 4/2 V Fine Sand Single grained Ab 20 22 2 5Y 4/1 Fine Sand Single grained E1 22 78 2 5Y 7/1 Fine Sand Single grained w/ few fine faint 2 5Y 6/8 mottles E2 78 88 10YR 7/1 Fine Sand Single grained estimated water table = 96 Bt 88 104 + 10YR 4/3 Fine Sand Single grained w/ man med distinct 10YR 4/2 if you have any questions or concerns please contact me at (910)297 1282 (910)795 0319 or by e mail at tgulley(ii,gmad coin Sincerely -1b-1l,I J Tom Gulley Jr North Carolina Soil Scientist # 1256 e E E E < J j ( E <f I < { .JE�s c E/ D s { A E E i t Y[ I I / $ / � I / a I f / I 9 / I / I � I I c �tl.e.r 9 ——________________ ---_----ten' _--_ Pansy Lane(24 a ci R/w) (r I R I, d s o) g5 c g$ @ q iP 1 zoo, 41 JUL 09 2010 U S ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Action Id SAW 2006 32402 071 County Pender US G S Quid Hampstead NOTIFICATION OF JURISDICTIONAL DEPERMINATION Applicant Mr limmv Elhn2ton, jr Addr ss 14921 US H vv 17 H imnstead NC 28443 Telephone No (910) 270 9576 Property description Size (acres) 8 acres Newest Wateiwiy Mill Creek USGS HUC 03010007 A ent Wes Fry ir, Land Mgna2em nt Group, I I C Address P O Box 2512 Wilmmt,tt n, NC 28402 f dephone No (910) 4�2 0001 Nearest Town Hampstead River Basin Cgpe Fe it River Coordinates N 34 3705 W 77 706 Locquon description Theft) icre site is located in he idwaters of Ilarnsons Creek on the west side of Hviv 17, off of Pansv Lane north of the mtei section of Hwv 210 West qnd Hwy 17 in H imustead, Pender County, North Cirolmi Indicate Whith of the Following Apply _ Based on preliminary mtormition there may be wetlands on the above described property NAe strongly suggest you have this property inspected to determine the extent of Department of the Army (DA) jurisdiction To be considered finil a junsdictiongl determination must be verified by the Coi ps This prehmmiry determination is not an appealable action under the Re,ulitory Proeram Administrative Appeal Process (Reference 33 CFR Part 331) _ There ire Navigable Waters of the United States within the above described propertv subject to the permit requirements of Section 10 of the Rivers qnd Harbors Act and Section 404 of the Clean Water Act Unless there is a chinge in the law or our published regulations this determination may be relied upon for i period not to exceed five years from the date of this nottftcgtion X _ We strongly suogcst you have the wetlands on your piopeity delineated Due to the size of your property indlot our present workload the Corps may not be able to accomplish this wetland delineation in a timely manner For a more timely delineation you mqy wish to obtain a consultant To be considered fin it any delineation must be verified by the Coi ps The waters of the U S on yom property have been delineated and the delmcinon has been verified by the Corps We strongly suggest you hive this delmcinon suiveyed Upon completion this survey should be reviewed and veufied by the Corps Once veufied this survey will provide qn gecutate depiction of all arees subject to CWAjunsdiction on yout property which provided there is no chinge in the liw m our published regulations may be relied upon for i period not to exceed five years _ The wetlands hive been delineated and surveyed and ire iccuratcly depicted on the plat signed by the Corps Re,ulatory Officigl identified below on Unless there is a chgnoc in the law or our published regulations this detei mmition may be relied upon for a period not to exceed five veers from the date, of this notification _ Thete are no waters of the U S to include wetlands present on the above described property which are subject to the permit requirements of Section 404 of the Clean Water Act (33 USC 1344) Unless there is i chinge in the, law of out published regulations this determination may be relied upon tot q period not to exceed five years from the dite of this nolifrcition The property is located in one of the 20 Cogstgl Comities subject to reaulition undet the Cogstgl Arci Management Act (CAMA) You should contact the Division of Cogstgl Mini.emcnt in Wilmm,ton NC it (910) 796 7215 to detertmne their iegmrements JUL 09 2010 Page 1 of 2 Action ID SAW 2006 32402 071 Placement of dredged or fill in itenal within waters of the US and/or wetlands without a Department of the At my peimit may constitute a %tolation of Section 301 of the Clean Water AU (33 USC § 1311) If you have any questions regarding this determination and/or the Corps regul story program please contact Emdv Burton at (910) 251 4630 Basis For Determination The subject area exhibits wetland criteria as described in the 1987 Corps Wetland Delineation Manual Wetlands are adjacent to Harrisons Creek a tributary to the Northe ist Cape Fear River, a Section 10 navigable water This determination was made by former Reeul itory Specialist I dletteGranade on Mav 31, 2006 Remarks Coops Regulatory Offival A `" ' "'r Date September 17, 2007 Expiration Date September 17, 2012 Corps Regulatory Offival (Initial) FOR OFFICE USE ONLY A plat or sketch of the propei ty and tha wetland data form must be ntached to the ]de copy of this fot in A copy of the Notification Of Administrative Appeal Options And Pioci,ss And Request For Appeal form must be tr insmitted with the propert) owner/agent copy of this form II the property contains isolated wetlands/waters please indicate in Remarks section and attach the Isolated Determination Information Sheet to the file copy of this form Page 2 of 2 US Army Corps of Engineers* N/11mmAton Distrfct Date September 17. 2007 ATTENTION PROPERTY OWNER New Guidance on Jurisdictional Determinations On June 5 2007 the U S Army Corps of Engineers (COE) implemented a new method for performing Jurisdictional deteimmations (JD) pursuant to the Clean Water Act (CWA) This new process is a result of the recent Supreme Court decisions (United States v Rapanos and United States v Carabell) and now requires the COE to conduct extensive reviews when deteimimng if ceitain waterbodies including wetlands haze a stgnificant nexus (connection) to Traditional Navigable Waters Since this Office has reviewed and verbally approved a Jurisdictional determination fot your property prior to June 5 2007 we have finalized this JD using the preN sous process However if you is the property owner are interested in having your property evaluated under the new guidance or have any questions regarding this mltter ple ise contact Emily Burton at 910 251 4635 f-.<-- S Kenneth Jolly Chief Regulatory Division �f�N"^'t.'#»P pto,r Tnr t+���fi$�E��¢ ��7�'�l.�pt�ilt ;.I.c� a,`4,' "i.3%x,ny'AR'a I�5'�#a?t i�� 7,j x t�' I i3Js?1.iL �i "I ��A '"4t,'87'�d{i3wr}��'a° Iw £R9,�& 4ki3l rfunAf'er T x`t61+L���'!Y is 8.r(i4i^!� y 14 NOTIFICATIONJOF�ADMINISITRATIV� "APPEAI OPTIONS#Ah�D PROCESS AND � e�tr stg1REQUEST9FORIAPPtEAL',p'rpf�' sir itt * , a v�q, ��7wa a a"a Y 1 94 xr,,i"5iu' rc t ar i rf,�'s .ti+!•' 9 G4'i I WI'I ! ih#9t'srFlk..€{r A hcant Mr Jimmy Ellington, Jr File Number 2006 32402 071 Date September 17, 2007 Attached is See Section below INITIAL PROFFERED PERMIT (Standard Permit or Letter of A permission) PROFFERED PERMIT (Standard Permit or Letter ofpermission) B PERMIT DENIAL C X APPROVED JURISDICTIONAL DETERMINATION D PRELIMINARY JURISDICTIONAL DETERMINATION E SECTIONhxJ fiThe'following identgifics�your rights and options4reg irdmggan administrative appeallof the,above ' decision YAdditio al mformahonlmaytbeffound(( at http //www usace at my mil/inet/functions/cw/cecwo/reg orl,,i r i '.';^' "'4 1; t f i "� I ! i G4 t f it F" U, r f i i .S`s 1 Co 331CFR Part 33) [1 � t" Ik r i (�.�'i't' i 4111 - r s regulations at lVi u i +' asp rMt � 'c" A INIrml, PROFFERED PERMIT You may accept or oblcct to lht permit ACCEPT If you received a Standard Pei mit you may sign the permit document and ieturn it to the district engineer for final authorization It you received a Letter of Permission (LOP) you may accept the LOP and your woik is authorized Your signature on the Standard Permit or acceptance of the LOP meam th it you accept the pet mrt in its entirety and waive all rights to appeal the permit including its terms and conditions and approved Jurisdictional determinations associated with the permit OBJECT If you object to the permit (Standard or LOP) because of certain terms and conditions thetun you in ty request that the permit be modified accordmaly You must complete Section II of this form and ieturn the form to the district engineer Your objections must be received by the district engineer within 60 clays of the date of this notice or you will forfeit your right to appeal the permit in the future Upon teceipt of your letter the disulct en ineer will evaluate your objections and may (a) modify the permit to address all of your concerns (b) modify the permit to address some of your objections or (c) not modify the permit having determined that the permit should be issued as previously «ritten Aftei evaluating your objections the district engineer will send you a proffered permit for your reconsideration as indicated in Section B below B PROFFERED PERMIT You may accept or appeal the permit ACCEPT If you received a Standard Permit you may sign the permit document and return it to the district engineer foi final authorization If you received a Letter of Permission (LOP) you may accept the LOP and your work is authorzed Your signature on the Standaid Permit or acceptance of the LOP means that You accept the permit in its entirely and waive all rights to appeal the permit including its terms and conditions and approved jurisdictional determinations associated with the permit APPEAL If you choose to decline the proffered permit (Standard or I OP) because of certain terms and conditions therein you may appeal the declined permit under the Corps of Engineers Administmuic Appeal Process by completing Section II of this form and sending the form to the division engineer This form must be received by the do ision engineer within 60 days of the date of this notice C PERMIT DENIAL You may appeal the denial of a permit under the Corps of Engineers Admrmstrztive Appeal Process by completing Section II of this form and sending the form to the division engmeer This form must be iecerved by the division engineer within 60 days of the date of this notice D APPROVED JURISDICTIONAL DETERMINATION You may acceptor appeal the approved JD or piovide new information ACCEPT You do not need to notify the Corps to accept an approved JD Failure to notds the Corps within 60 days of the date of this notice means that you iccept the approved JD in its entirety and wane all rtehts to appeal the approved JD APPEAL 11 you dis agree with the ipproved JD You in iy appeal the approved JD under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer This foi in must be received by the division engineer within 60 d iys of the date of this notice E PRELIMINARY JURISDICTIONAL DETERMINATION You do not need to respond to the Corps reglydmg the preliminary JD The Preliminary JD is not appealable If you wish you may request an approved JD (which may be appealed) by contacting the Corps district for further instruction Also you may provide new information further consideration by the Corps to reevaluate the JD yfor PERMIT 1 SECTION II REQUESTsFOR-APPEALlor OBJECTIONS TO AN INITIAL PROFFERED REASONS FOR APPEAL OR OBJECTIONS (Descube your re isons for appealing the decision or your objections to an initial proffered permit in cleat concise statements You may att ich additional information to this form to clarify where your reasons or objections are addressed in the administrative record ) ADDITIONAL INFORMATION The appeal is limited to a review of the administrative record the Corps memorandum for the record of the appeal conference or meeting and any supplemental information that the review officer has determined is needed to clarify the administrative record Neither the appellant nor the Corps m-iy add new information or analyses to the record However you m-iy provide additional infoimation to clarify the location of Information that is already in the tdmmistrative record POINTLOF CONTACT FOR QUESTIONS "OR&INFORMATION t-J If you have questions regarding this decision If you only have questions regarding the appe-il process you ma} and/or the appeal process you may contact also cont ict Emily Burton Regull[ory Specialist Mr Mike Bell Administrative Appeal Review Officer U S Army Corps of Engineers Wilmington CESAD ET CO R District U S Army Corps of Engineers South Atlantic Division 69 Darlington Ave 60 Forsyth Street Room 9M15 Wilmington NC 28402 Atlanta Georgia 30303 8801 RIGHT OF ENTRY Your signatute below grants the right of entry to Corps of Engineers personnel -ind and government consultants to conduct investigations of the project site during the course of the appeal process You will be provided a 15 day notice of any site investigation and will have the oppoitumty to participate In all site investigations Date Telephone number Signature of ippellant or agent E PRELIMINARY JURISDICTIONAL DETERMINATION You do not need to respond to the Corps regaidmg the pielimmary JD The Preliminary JD is not appcilable If you wish you may request an approved JD (which may be appealed) by contacting the Coips district for further instruction Also you may provide new information for further consideration by the Coips to reevalu ite the JD is s€ E l Y h i a u i a� �, tf tit l F 3iir } ;4 a Nr 4 $ 11 F ¢ v I � 7 ' i # �1 SECTION II -REQUEST FOR AP EAL'oi OBJECTIONS'TO AN INITIAL PROFFEREDIPERmmT tk REASONS FOR APPEAL OR OBJECTIONS (Desciibe your reasons toi appe ilmg the decision or your objections to an initial proffeied permit in cleai concise statements You m1y attach addition it information to this foim to clarify wheie youi reasons or objections are addressed in the administrative recoid ) ADDITIONAL INFORMATION The appeal is limited to a review of the ldmmistrative record the Corps memorandum foi the record of the appeal conference or meeting and any supplemental information that the review officer has determined is needed to clarify the idministrative iecoid Neither the appellant nor the Corps may add new information or analyses to the record However you miy piovide additional infoim-ition to clarify the location of information that is alieady in the idministrative record POINTt10FCONTACToFOR tQUESTIONS'ORiNFORMATION' If you have questions regarding this decision if you only have questions regarding the appe-il process you may and/or the appeal process you may contact also contact Emily Burton Regulatory Specialist Mr Mike Bell Administrative Appeal Review Officer U S Army Corps of Engineers Wilmington CESAD ET CO R District U S Army Corps of Engineers South Atlantic Division 69 Darlington Ave 60 Forsyth Street Room 9M15 Wilmington NC 28402 Atlanta Georgia 30303 8801 RIGHT OF ENTRY Your signature below grants the right of entry to Coips of Engineers personnel -ind any government consultants to conduct investigations of the project site during the course of the appeal process You will be provided 2 15 d ty notice of 1ny site investigation and will have the oppoitunity to participate in all site investigations Date Telephone number Signature of ippellant or lgent J U S ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Action Id 200401021 County Pender NOTIFICATION OF JURISDICTIONAL DETERMINATION Applicant Jimmy Ellington Address Post Office Box 214 Hampstead NC28443 Telephone (910) 200 8375 Agent Kurt Evens Land Management Group Inc Post Office Box 2522 Wilmington NC 28402 (910) 452 0001 Quad Hampstead Size and Location of Property (waterbody Highway name/number town etc ) The site is located in headwaters of Harrison Creek on the west side of Hwy 17 on Pansy Lane north of the intersection of Hwy 210 West and Hwy 17 in Hampstead Pender County North Carolina Indicate Which of the Following Apply Based on preliminary information there may be wetlands on the above described property We strongly suggest you have this property inspected to determine the extent of Department of the Army (DA) junsdiction To be considered final a junsdictional determination must be venfied by the Corps X There are wetlands on the above described property subject to the permit requirements of Section 404 of the Clean Water Act (CVIA)(33 USC § 1344) Unless there is a change in the law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification _ We strongly suggest you have the wetlands on your property delineated Due to the size of your property and/or our present workload the Corps may not be able to accomplish this wetland delineation in a timely manner For a more timely delineation you may wish to obtain a consultant To be considered final any delineation must be verified by the Corps _ The wetlands on your property have been delineated and the delineation has been verified by the Corps We strongly suggest you have tlus delineation surveyed Upon completion, this survey should be reviewed and verified by the Corps Onceverified this survey will provide an accurate depiction of all areas subject to CWA Jurisdiction on your property which provided there is no change in the law or our published regulations may be relied upon for a period not to exceed five years a X The wetlands have been delineated and surweyed and are accurately depicted on the plat signed by the Corps Regulatory Official identified below on August 6, 2004 Unless there is a change in the law or our published regulations, this determination may be relied upon for a period not to exceed five wears from the date of this notification _ There are no waters of the U S to include wetlands present on the above described property which are subject to the permit requirements of Section 404 of the Clean Water Act (33 USC 1344) Unless there is a change in the law or our published regulations this determination may be relied upon for a period not to exceed five years from the date of this notification X The property is located in one of the 20 Coastal Counties subject to regulation under the Coastal Area Management Act (CAMA) You should contact the Division of Coastal Management in Wdmmeton NC at (910) 395 3900 to determine their requirements Corps Regulatory Official �� Date August 6, 2004 Expiration Date August 6, 2009 Page 1 of 2 Action Id 200401021 Placement of dredged or fill material within waters of the US and/or wetlands without a Department of the Army permit may constitute a violation of Section 301 of the Clean Water Act (33 USC § 1311) If you have any questions regarding this determination and/or the Corps regulatory program, please contact Ldlette Granade at (910) 251 4829 Basis For Determination This site exhibits wetland criteria as described by the 1987 Corps Wetland Delineation Manual and is part of a broad continuum of wetlands connected to Hamsons Creek, a tributary to the Northeast Cape Fear River Detemunatron is based on information provided by Kurt Evers of Land Management Group Inc and a field visit by Lillette Granade on July 7 2004 Corps Regulatory Official (Initial) FOR OFFICE USE ONLY A plat or sketch of the property and the wetland data form must be attached to the file copy of this form A copy of the Notification Of Administrative Appeal Options And Process And Request For Appeal form must be transmitted with the property owner/agent copy of this form If the property contains isolated wetlands/waters please indicate in Remarks section and attach the Isolated Determination Information Sheet to the file copy of this form Page 2 of 2 r p j Y k FM M Jimmy Ellington File Number 200401021 Date August 6 2004 Applicant Attached is See Section below INITIAL PROFFERED PERMIT (Standard Permit or Letter of A ermission PROFFERED PERMIT Standard Permit or Letter ofpermission) B PERMIT DENIAL C X APPROVED JURISDICTIONAL DETERMINATION D PRELIMINARY JURISDICTIONAL DETERMINATION E �SEG�FT©N� "�Pherfallorvlii ��denii&es�ouiinghts"andlopho�is�regardingian�a",d�rus(rafii�e��ap �� oath �a�io e tix,il{�, t ��/ lnnd la �et�wb��e { l�i � � t� �det � �t� ��d� ltti°l n1alf�rnfojiiiiat tE�ij uia�t�b�e fo ht �'�ww�v usceEe�� mil/me�ifimtcti ris�lc�� f A INITIAL PROFFERED PERMIT You may acceptor object to the permit ACCEPT If you received a Standard Permit you may sign the perni t document and return it to the district engineer for final authorization If you received a Letter of Permussion (LOP) you may accept the LOP and your work is authorized Your signature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety and waive all rights to appeal the permit including its terms and conditions and approved jurisdictional determinations associated with the permit • OBJECT If you object to the permit (Standard or LOP) because of certain teams and conditions therein you may request that the permit be modified accordingly You must complete Section II of this form and return the form to the district engineer Your objections must be received by the district engineer within 60 days of the date of this notice or you will forfeit your right to appeal the permit in the future Upon receipt of your letter the district engineer will evaluate your objections and may (a) modify the permit to address all of your concerns (b) modify the permit to address some of your objections or (c) not modify the permit having determined that the permit should be issued as previously written After evaluating your objections the district engineer will send you a proffered permit for your reconsideration as indicated in Section B below B PROFFERED PERMIT You may accept or appeal the permit ACCEPT If you received a Standard Pemut you may sign the permit document and return it to the district engineer for final authorization If you received a Letter of Pemussion (LOP) you may accept the LOP and your work is authorized Your signature on the Standard Permit or acceptance of the LOP means that you accept the pemut in its entirety and waive all rights to appeal the perrrut including its terms and conditions and approved jurisdictional determinations associated with the permit • APPEAL If you choose to decline the proffered permit (Standard or LOP) because of certain terms and conditions therein you may appeal the declined permit under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer This form must be received by the division engineer within 60 days of the date of this notice C PERMIT DENIAL You may appeal the denial of a permit under the Corps of Engineers Administrative Appeal Process by completing Section 11 of this form and sending the form to the division engineer This form must be received by the division engineer within 60 days of the date of this notice D APPROVED JURISDICTIONAL DETERMINATION You may accept or appeal the approved JD or provide new information ACCEPT You do not need to notify the Corps to accept an approved JD Failure to notify the Corps within 60 days of the date of this notice means that you accept the approved JD in its entirety and waive all rights to appeal the approved JD • APPEAL If you disagree with the approved JD you may appeal the approved JD under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer This form must be received by the division engineer within 60 days of the date of this notice E PRELIMINARY JURISDICTIONAL DETERMINATION You do not need to respond to the Corps regarding the preliminary JD The Preliminary JD is not appealable If you wish you may request an approved JD (which maybe appealed) by contacting the Corps district for further instruction Also you may provide new information for further consideration by the Corps to reevaluate the JD 15� I ON4 xx nit} i � lfa �17 1 G Is � S UNIX [ 1INO�A)i tl Ql C TIO TjO iAIV F � 1 olr S li jPRO� E I P PEI TI REASONS FOR APPEAL OR OBJECTIONS (Describe your reasons for appealing the decision or your objections to an initial proffered permit in clear concise statements You may attach additional information to this form to clarify where your reasons or objections are addressed in the administrative record ) ADDITIONAL INFORMATION The appeal is limited to a review of the administrative record the Corps memorandum for the record of the appeal conference or meeting and any supplemental information that the review officer has determined is needed to clarify the administrative record Neither the appellant nor the Corps may add new information or analyses to the record However you may provide additional information to clarify the location of information that is already in the administrative record O li®k,CON� A@ qIFOR b ES �lONSIO.>ZIlINFORIATTQN Ilk i l �II4�li I�i�`[ili�� I sll° 3iik�il13 1 If you have questions regarding this decision If you only have questions regarding the appeal process you and/or the appeal process you may contact may also contact Lillette Granade Mr Arthur Middleton Administrative Appeal Review Officer U S Army Corps of Engineers Wilmington Dist CESAD ET CO R 69 Darlington Avenue U S Army Corps of Engineers South Atlantic Division Wilmington North Carolina 28402 60 Forsyth Street Room 9M15 Atlanta Georgia 30303 8801 RIGHT OF ENTRY Your signature below grants the tight of entry to Corps of Engineers personnel and any government consultants to conduct investigations of the project site during the course of the appeal process You will be provided a 15 day notice of any site investigation and will have the opportunity to participate in all site investigations Date Telephone number Signature of appellant or agent Johnson, Kelly From Johnson Kelly Sent Thursday July 08 2010 10 38 AM To mtackett@clarkgroup us Subject Cypress Grove Townhomes Michael We received this application and I went through it this morning I have a few questions for you 1 SHWT I do not see the soil boring data in this submittal? This pond will be deepened from what was previously permitted The PP is still at 44 00 and the TP is still at 45 67 but the bottom of the pond went from 39 00 to 38 00 in order to accommodate the increase in BUA and DA Since the pond is being deepened it must be designed per the latest design requirements including determining the SHWT [Under Section 2 (d)(5) of Session Law 2008 211 which replaced Section 1005 in the stormwater rules minor modifications to a project are exempt from having to comply with the newer rules A minor modification in the 2008 rules is defined as one that does not increase the net amount of built upon area or does not increase the overall size of the previously permitted stormwater controls If a previously permitted pond can accommodate additional BUA (both in the pond area and volume) without having to be increased in size (i a no enlargement of the surface area is needed or the pond doesn t have to be deepened) then the pond doesn t have to provide all the new requirements such as the determination of the SHWT Tweaking the elevations of the orifice and temporary pool slightly without having to excavate the pond to gain extra area and/or design volume is OK But if you have to increase the pond surface area via excavation or deepen the pond or if the existing elevations had to be more than just tweaked a bit then the pond would have to be redesigned per today s standards ] Please submit the SHWT boring information 2 Designer's Certification Please submit a partial designer's certification for the portions of the site that have been completed 3 Plans I have not gone through the plans thoroughly but I did not see a note that there were no wetlands present and I also did not see any delineated Please provide one of these two if you have not already Please also ensure that the project boundary BUA dimensions grading details etc are included if you have not already As you may know we go through each application when it comes in to ensure that we have all of the necessary paperwork If something is missing such as the SHWT boring info or the designer certification we ask that that be submitted by COB the next day so that we can log it in to the system and it can be assigned to a review engineer If the information will take longer to compile then we return the application Please forward this information by COB tomorrow (Via email is fine ) Thanks Kelly *** My email has changed to kelly a iohnson@ncdenr gov K.6LW0hws0w Kelly Johnson Environmental Engineer Division of Water Quality Stormwater Permitting 227 Cardinal Drive Extension Wilmington NC 28405 3845 Office 910 796 7345 Fax 910 350 2004 E mad correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties The Clar oup POST OFFICE B X1 POST OFFICE BOX 10136 WILMINGTON NC 28404 0136 r LETTER OF' RANSNUTTAL [Co] Al L �L-N r J wjm n n e o w OT %/c /Z I �r sr h W, Ivn wIOr1 /t!L Z g S WE ARE SENDING YOU X ATTACHED_ SHIPPED VIA THE FOLLOWING DATE G Z v PROJECT NOD96oe ATTENTION AnA 1r � RE Pec'" 4-Modcakoh Z- SW oY�ZZG UNDER SEPARATE COVER OTHER (SPECIFY) NO COPIES DATE DESCRIPTION Z Piz S%!o Plops A( rtss S4 ors Z 21 110 ticn, 6--- P-r-k4f.- Pe C rn k ApeI G THESE ITEMS ARE TRANSMITTED AS CHECKED BELOW FOR APPROVAL _ FOR YOUR USE _ AS REQUESTED _ FOR REVIEW/COMMENT CYPRESS STATION (CYPRESS GROVE TOWNHOMES) STORM WATER MODIFICATION For SW8 070226 NARRATIVE RECEIVED JUN 2 9 2010 BY Cypress Station is a mixed use High Density Development consisting of Townhomes and Commercial properties Cypress Station is a new addition to Cypress Grove Townhomes Development The purpose of this modification to NCDWQ permit No SW8 070226 is to revise the Wet Detention Basin Pond B and add three commercial outparcel lots to Pond B s drainage area No other modifications or changes to the site or existing plans for Cypress Grove Townhomes will take place All previous storm water sedimentation & erosion control and grading plans will remain as approved with the exception of the modifications to Pond B CYPRESS STATION LIST OF LOTS AND PROPOSED BUA LOT # LOT SIZE ALLOWABLE BUA (AC / SF) (SF) 195 / 85 136 61 870 1 42 / 61 768 49 417 1 23 / 53 472 38 014 CYPRESS GROVE TOWNHOMES PREVIOUSLY APPROVED BUA LOT 4 LOT SIZE ALLOWABLE BUA (AC / SF) (SF) 600 / 261 261 128 808 (Lot size and BUA per SW8 070266 for Ponds A & B) 2 CYPRESS STATION A�� w NC NORTH CLARK PROJECT NO 09608 A Oct. • `-� PROJECT SITE d •• ampsteae �- ,�W�`-�llL-_-/\/ / ` ff 1 f f i ♦ Imo( i ^ � "FOR ILLUSTRATIVE D PURPOSES ONLY THIS MAP IS NOT A CERTIFIED SURVEY AND HAS NOT BEEN REVIEWED BY A LOCAL t GOVERNMENTAGENCYFOR • ` COMPLIANCE WITH ANY APPLICABLE , LAND DEVELOPMENT REGULATIONS • :. • • r HAMPSTEAD QUADRANGLE EXHIBIT MAP \V THE CLARK NORTH CAROLINA PENDER COUNTY GROUP 7 5 MINUTE SERIES (TOPOGRAPHIC) 1997 DRAWNBY DATE W R D 1 6/8/10 WET DETENTION BASIN DATA SHEET DE51GN CALCULATIONS FOR POND B DRAINAGE AREA (Ad) = IMPERVIOUS AREA (A1) 33G 241 5Q PT BUILDINGS 31 110 SQ PT ROADS 33 G72 5Q IT 51DEWALKS 1 792 5Q IT PARKING 9 845 SQ FT FUTURE (RESERVE) 131 927 5Q FT TOTAL 208 34G 5Q FT PERCENT IMPERVIOUS (1) I = AI/Ad = G 19G% CALCULATE AVERAGE DEPTH (Davg) DATE G/2/ 10 PROJECT NO 9GO8 DESIGNED BY MLT SEE AVERAGE DEPTH CALCULATION SPREADSHEET FOR POND B CALCULATE REQUIRED SURFACE AREA AT PERMANENT POOL �`�\, \A1CAR0/// 6 OREss/0y�y�� �� EA CT 7 GINO; W cN CAo WTIK�� v L 4556 p:7 9p03URV��a11 F�LEE I PF 11111 POND B 5HALL HAVE AN AVERAGE DEPTH OF 5 00 AND BE DESIGNED TO REMOVE 90% T55 INTERPOLATION Of TABLE 10 4 IN NCDENR STORMWATER BMP MANUAL IMP AVERAGE DEPTH (PT) 45 500 55 GO 450 430 390 GI 9G 494 444 402 70 5 50 500 4 50 5A/DA= 4 44% 5AREQ = 14 920 SP = 034 AC SURFACE AREA PROVIDED AT PERMANENT POOL (ELEV 44 00) = 15 30G 5P SA PROV D= 15 30C > 14 920 =SA REQ D OK POND #B DATA 5HEET PAGE I OF 4 POND CALC CYPRE55 5TATION REV OGO410 1 MINIMUM REQUIRED VOLUME (SIMPLE METHOD BY TOM 5CHUELER) Rv=O 05+0 009 (1) Rv= 0 G07G7 VOLUME= 1 5 Rv Ad = 0 58G327G AC FT 25 540 FT^3 VOLUME PROVIDED AT TEMPORARY POOL INCREM TOTAL EL. 5A (5F) VOL, (CF) VOL (CF) 44 15 30G 0 0 445 18 184 8 373 8 373 45 19 080 9 3 I G 17 G59 45 G7 20 302 13 193 30 881 4G 20 913 G 800 37 G82 MINIMUM TEMP POOL ELEVATION (FROM SIMPLE METHOD VOLUME) REQ D EL = 4540 VOL REQ D = 25 540 CF TEMP POOL ELEVATION OUTLET EL = 45 G7 VOL PROV D = 30 881 CF NOTE SINCE THE ELEVATION OF THE NEXT AVAILABLE OUTLET ABOVE THE NORMAL POOL 15 GREATER THAN THE MINIMUM TEMP POOL ELEVATION THE OUTLET ELEVATION 15 THE TEMPORARY POOL ELEVATION VOL PROVD= 30881 > 25 540 =VOL REQD OK POND #15 DATA SHEET PAGE 2 OF 4 POND CALC CYPRE55 5TATION REV 00041 0 15 FOREBAY SIZING PERMANENT POOL VOLUME EL. 39 G 14G 40 7 4G4 41 8 847 42 10 255 43 1 1 809 43 5 12 590 44 15 30G 445 18 184 45 19 080 45 G7 20 302 4G 20913 47 22 803 REQD VOLUME = 20%TOTAL = CHECK POREBAY VOLUME (3 1 CONTOURS) INCREM TOTAL 0 0 G 805 G 605 8 I5G 149G1 9 57 1 24 532 1 1 052 35 584 G 100 41 C83 G 974 48 G57 8 373 57 030 9 3 1 G GG 34G 13 193 79 539 G 800 8G 339 21 858 108 107 9 73 1 CP (2 1 CONTOURS) INCREM TOTAL EL, SA (5E) VOL, (CE) Vim_( 39 0 0 0 40 0 0 0 41 2 390 0 0 42 3 27G 2 833 2 833 43 3 808 3 542 G 375 44 4 372 4 090 10 4G5 45 4 9G8 4 G70 15 135 45 G7 5 595 3 539 18 G74 4G G 254 1 955 20 C29 47 G 943 G 599 27 227 48 7 GG3 7 303 34 530 PROV D VOLUME = 10 4G5 CF (3 DEEP FOREBAY) 4-- (SA PEQT MET1) VOL PROV D= 1 0 4G5 9 73 1 =VOL REQD OK POND #B DATA 5HEET PAGE 3 OF 4 POND CALC CYPRESS STATION REV 00041 O X15 ORIFICE 51ZING REQD DRAWDOWN TIME = 2 5 DAYS NOTE ORIFICE SIZED TO DRAWDOWN THE TEMPORARY POOL IN 2 5 DAY5 Q2= 0 14750 CF5 (FOR 2 DAY DRAWDOWN) Q5= 0 059 12 CF5 (FOR 5 DAY DRAWDOWN) ORIFICE EL = 44 00 (PERM POOL EL ) TEMP POOL EL = 45 G7 (OUTLET EL) ORIFICE DIAMETER = 200 IN Q PROV D= Cd A (2gh) ^ 112 Q PROV D= 007838 WHERE Cd= 0 G A= 0 02182 5F g= 322 FPS/5 h= (TEMP POOL NORMAL POOL)/3 = 0 55GG7 Q2> 0 07838 >Q5 OK DRAWDOWN TIME TIME = VOLUM = Q PROV D 377 DAYS POND #B DATA SHEET PAGE 4 OF 4 POND CALC CYPRE55 5TATION REV 000410 15 GROUPTHE CLARK 5000 Blue Clay Road DRAINAGE COMPUTATIONS FOR CYPRESS STATION SUBMITTED BY Castle Hayne North Carolina ly www ... ..- maa®gym®m���®� • mmmm maa��mmm���®��mmmm® mmm��mm����m��mmmm■�■ AVERAGE DEPTH CALCULATION DESIGN CALCULATIONS FOR POND B Option # I DEPTH (FT) SURFACE AREA AT DEPTH (5F) INC VOL AT DEPTH (CF) TOTALVOL AT DEPTH (CF) Option #I (FT) 00 15 3OG 0 0 000 05 12 590 G 974 G 974 0 4C 1 0 1 1 809 G 100 13074 085 1 5 1 1 044 5 713 18 787 123 20 10 295 5 335 24 122 158 25 9 5G3 4 9G5 29 08G 190 30 8 547 4 G03 33 G59 220 3 5 8 147 4 249 37 937 246 40 7 4G4 3 903 41 840 273 45 G 797 3 5G5 45 405 297 50 G 14G 3 23G 48 G41 3 18 55 5512 2915 51 55G 337 GO G5 70 75 80 85 Depth of 0 0 ft = perm Pool elev Of 44 00 Depth of 5 0 ft = Bottom Pond elev Of 39 00 POND CALC CYPPE55 5TATION REV 060410 1 DATE 8/ 1 0/ 1 O PROJECT NO 9GO8 DE51GNED BY MLT Option #2 Abut h If = 12590 51' A , = 15 30G SF Ab t d = G 1 4G 5F Depth = 50 FT D = 4 18 FT AUG 302010 POND #B AVG DEPTH PAGE I OF I SOSID 1087445 Date Filed 3/9/2009 2 30 00 PM Elaine F Marshall ARTICLES OF ORGANIZATION North Carolma Secretary of State OF C200906800526 CYPRESS COEX LLC Pursuant to 57C 2 20 of the General Statutes of North Carolina the undersigned Organizer herebv submits these Articles of Organization for the purpose of forming a limited liability company I The name of the limited lability company is CYPRESS COEX LLC 2 If the limited lability company is to dissolve by a specific date the latest date on which the limited liability company is to dissolve is (Ifno datefor dissolution is specified there shall be no limit on the duration ofthe limited liability company) 3 The name and address of each person executing these articles of organization is as follows (State whether each person is executing these articles of organization in the capacity of a member organi er or both) James B Snow III Organizer 101 South Third Street Wilmington North Carolina 28401 4 The street address and county of the initial registered office of the limited liability company is 7036 Wrightsville Avenue Suite 101 Wilmington North Carolina 28403 located in New Hanover County North Carolina 5 The mailing if different from the street of the initial registered office is 6 The name of the initial registered agent is J Wnght Holman Ill LJUN 7 Pnncipal office information (Select either a orb) Xq2010a ®The hmned lability company has a pnncipal officeThe street address and county of the principal office of the hmned liability company Number and Street 7036 Wrightsville Avenue, Suite 101 City State Zip Code Wilmington, NC, 28403 County New Hanover The mailing address tf different from the street address of the principal office of the limited liability company is b ❑ The limited liability company does not have a principal office 8 Check one of the following Member managed LLC all of the members by virtue of their status as members shall be managers of this limited liability company X Manager managed LLC except as provided by NCGS §57C3 20(a) the members of this limited liability company shall not be managers by virtue of their status as members 9 These articles will be effective upon filing /ice n This the b day of �Ux^ Z S UBSIMEII EI J mmyW ym1R\Cypm C LLC OpAgm M Mvug dW thA i s ( 1111111111111111111111111111111111111r Fms8 Pop' 3 �aoea PIN # 3;aa-gB-SY5q Tr )9-(o'o9 INT - Prepared by & returned to MCGUIREWOODB LLP(DEH) 300 Nart dStreet, rte 400 mgum North Carolina I Revenue Stamps — r 3262 98 6489 0000 STATE OF NORTH CAROLINA GENERAL WARRANTY DEED COUNTY OF PENDER THIS GENERAL WARRANTY DEED (this Deed ) made and entered into this I st day of August 2009 by and between Buckeye Capital LLC a Connecticut limited liability company (the Grantor ) and Cypress Coex LLC a North Carol na I in ted habil ty company (the Grantee ) whose address s 7036 Wrightsville Ave.. c„its 101 Wilmington NC 28403 WITNESSETH THAT the Grantor for and in cons deration of the sum of Ten Dollars (S 10 00) and other good and aluable co s d anon the receipt and suffieie y f whi h h reby ack owledged does grant bargain sell and convey unto the G antee in fee simple all of that certain property situated in Topsa I Township Pender County North Carol na and more pamcularly described as follows Se Exhibit A attached hereto and incorporated herein by reference as if fully set forth TO HAVE AND TO HOLD the aforesa d p op rty together w th all easeme is t in t pr vtleges a d ppurt ances the eunto belonging to the Grantee in fee simple fore e And the Grantor covenants with the Grantee that Granto s s zed of the said premises in fee simple and has the right to convey the same n fee s mple that t tic to the same is marketable and free from encumbrances except those set forth below a d that the Gra to w II warrant and defend the title aga nst the cla ms of all persons whatsoe er except for the exceptions h re aft r stat d �lJk gkt cote" -,, 3 RECEIVED JUN 2 9 M0 BY iiiiiiiuiiiiiiiiiiiii�igiiiir3665 P0260o z3 paooa Title to the property here nabove described is subject to the following exceptions 1 2009 ad valorem taxes 2 Easeme is restnctions and rights -of way of record 3 Applicable ord nances statutes regulations and other laws and 4 Matters which would be rev led by a cuff t and accurate survey IN WITNESS WHEREOF the Grantor has duly executed th s Deed all as of the day and year first above written Buckeye Capital LLC (SEAL) By ZC� �(Seal) Name M ullry }� T tic Ma ag By %�(Se 1) N an Da CS Su van Title Manage STATE OF NORTH CLAROLINNA� COUNTY OF�✓� � 1 v a Notary Public do hereby certify that Mark D Sulli an d Dan el J Sull an p rsonally appeared before me this day and acknowledged that they are Managers of Buckeye Capital LLC a Connecticut limited I ab I ty company and that by authorityduly g en and as the act of the company the foregoing instrument was signed and sealed in its name by them as is Ma age s WITNESS my hand and notarial seal th s 30 day of 2009 Notary bl c� PrintarTypeName L[7m SQ p''Tl Al Seery :P My Commisson Expires \9r090r4i IIIIIIIIIIIIIIIIIIIIIIII1IIIIIIIIIIII, 83665 P0261P =3,�maeo Exhibit A Lying and being in Topsail Township Pender County North Carolina and more particularly described as follows Being that Tract of land containing 4 5994 Acres as the same is shown on a map entitled Survey of Property for Jerry Sullivan recorded in Map Book 48 at page 065 slide 650 of the Pender County Registry reference to which said map is hereby made for a more particular description t97 N0741 t ee III IIIIIIIIII IIIIIIIIIIII IIIIIIIII III e366� P0255Pa mail aaa Vend C unty NC R 91 t f e d V O I f 4 3049-Be-13sa— gaga qg rdk Oem �Iv 3?ea ss- visa, P epmed by & returned to MCGuiREWOODS LLP(DEH) 300 North Third Street Suite 400 wdmm o t_Ca as 28401 Revenue Stamps-$ v Tax Parcel Number Tract 1 3282 88 7389 0000 & 3282 884226 0000 Tract 2 3282 98 4294 0000 STATE OF NORTH CAROLINA GENERAL WARRANTY DEED COUNTY OF PENDER THIS GENERAL WARRANTY DEED (this Deed ) made and ente ed nto this I st day of August 2009 by and between Cyp ess Grove Townhomes LLC North Carolina limited I b i ty company (the Grantor ) and Cypress Coex LLC a North Carolm 1 in t d I ability comp y (the Grantee ) whose ddress is 7036 HrIgbitsizille Aye - cnl ee 101 Wilming[ n NC 28403 WITNESSETH THAT the Grantor for and in consideration of the sum of Te Dollars ($10 00) nd other good and valuable consideratio the receipt and sufficiency of wh ch are hereby cknowledged does g in bargain sell and convey unto the Grantee in fee simple all of that certain property situ ted Topsail Township Pende County North Ca of na and more part c larly described as follows Se E h b t A attach d hereto a d e co In ated here by Terence a f f Ily s t forth TO HAVE AND TO HOLD the afo esa d property together with II aseme is tenem nts privileges and app rienanc s thereunto belonging to the Grantee n fee s mple to eve A d the G antor cc e a is w th the Gra to that Grantor s seized of the sa it p emises in fe s mple and has the right to onv y the same in fe s mpl that title to the same is marketable and free ✓WR+,Y tolef) JUN 2 9 2010 d�ty NC R gi t,3665 P0256Pf°.,t°oo from encumbrances except those set forth below and that the Grantor will warrant and defend the title against the claims of all persons whatsoever except for the a cept ons hereinafter stated Title to the property heremabove described is subject to the following exceptions 2009 ad valo em taxes 2 Easements restr coons and rights of way of re o d 3 Appl cable ordinances statutes egulauons and other laws and 4 Matters which would be revealed by a current and accurate survey 5 The ben of a Deed of Trust from Cypress Gro a Townhomes LLC to Frederick Wdletts III Trustee and Cooperative Bank recorded September 26 2007 in Book 3324 Page 159 of the Pender Co my Registry the terms of wh ch are hereby assumed by the Grantee 6 An Assignment of Leases and Rents from Cypress Grove Townhomes LLC to Cooperative Bank recorded in Book 3324 Page 171 in the Pender County Registry IN WITNESS WHEREOF the Grantor has duly executed this Deed all as of the day and year first above written Cypress G ove Townhomes LLC (SEAL) By Keys & Holman Family Pr ies C ember Manager (Seal) By ea N e J Wright rtle Manager By Buckeye Properties LLC Member Manager (Seal) By Gat,,,g— — \ 7, Z (Seal) Name Daniel J Sul[ van Title Me ager� W7088% I Rev seE F..T with m.TO . IIIIIIIIIIIIIIIIIIIILIII1IIIIIIIIIIII 13665 PM7P � 9ooa P d C.t, yl t f o d P W a f Exhibit A Lying and being in Topsail Township Pender County North Carolina and more particularly described as follows TRACT 1 (Tax Parcels 3282 88 7389 0000 & 3282 88 4226 0000) BEING all of Tract 2 contacting 10 00 Acres and shown on a Recombination plat for owners Jimmy W Ellington Jr and James W & Geraldine D Nelson Jr by Talbot Land Surveying P C recorded in Map Book 42 Page 67 of the Pender County Registry reference to which plat is hereby made for a more complete description TRACT 2 (Tax Parcel 3282 98 4294 0000) BEING all of Lot Nos Twenty Three (23) Twenty Four (24) Twenty Five (25) Twenty Six (26) of the A B Crumpler Property in the Town of Hampstead as shown by plat recorded in the office of the Register of Deeds for Pender County in Book 72 at Page 491 and being part of the property conveyed to the Board of Education by a Deed dated March 26 1912 recorded in Book 84 at Page 270 in the records of Pender County W7088901 R dne dF omT M. ToCoe III I IIIIIIIIIIIIIIIIIII11IIIIIIIIIIII 8356; P6258 °a ea ssamma F iW C only Nc 91 ! ( a d P o IPf 1!! STATE OF NORTH CAROLINA COUNTY OF NEW HANOVER I Elizabeth B Lamkm a Notary Public do hereby certify that 1 Wright Holman and J Daniel Sullivan personally appeared before me this day and acknowledged that they are Managers of Cypress Grove Townhomes LLC a North Carolina limited liability company and that by authority duly given and as the act of the company the foregoing instrument was signed and sealed in its time by them as its Managers WITNESS my hand and notarial seal this the 30 day of July 2009 414 i/, a /J / ;e C7 Notaryryblic ' Print o ype Name Elizabeth B Lamkin My Commission Expires SOSID 1087445 Date Filed 3/9/2009 2 30 00 PM Elaine F Marshall ARTICLES OF ORGANIZATION North Carolina Secretary of State OF C200906800526 CYPRESS COEX LLC Pursuant to 57C 2 20 of the General Statutes of North Carolina the undersigned Organizer hereby submits these Articles of Organization for the purpose of forming a limited Lability company I The name of the limited liability company is CYPRESS COEX LLC 2 If the limited liability company is to dissolve by a specific date the latest date on which the limited liability company is to dissolve is (lfno date for dissolution is specified there shall be no limn on the duration of the limited liability company) 3 The name and address of each person executing these articles of organization is as follows (State whether each person is executing these articles of organization in the capacity of a member organi er or both) James B Snow III Organizer 101 South Third Street Wilmington North Carolina 28401 4 The street address and county of the initial registered office of the limited liability company is 7036 Wrightsville Avenue Suite 101 Wilmington North Carolina 28403 located in New Hanover County North Carolina 5 The mailing if different from the street of the initial registered office is 6 The name of the initial registered agent is 1 Wright Holman 111 =A.:,. 7 Principal office information (Select either a or b) a ® The limited liability company has a principal office The street address and county of the principal office of the limited liability company is Number and Street 7036 Wnehtsville Avenue, Suite 101 City State Zip Code Wilmmeton, NC, 28403 County New Hanover The mailing address If different from the street address of the principal office of the limited liability company is b ❑ The limited liability company does not have a principal office 8 Check one of the following Member managed LLC all of the members by virtue of their status as members shall be managers of this limited liability company X Manager managed LLC except as provided by NCGS §57C3 20(a) the members of this limited liability company shall not be managers by virtue of their status as members 9 These articles will be effective upon filing o This the !—� y of / / t�� cz S VBSIII CII g 1 mmyW y 1R\Cyp C LLC OpAgm Ma Manage W hA I e ( LIMITED LIABILITY COMPANY o ANNUAL REPORT NAMF Oh LIMI lED I [ABILITY COMPANY CYPRESSCOEX LLC SECRETARY OI S f A rE L I C ID NUMBER 1087445 NAIUREOFBUSINFSS RealFstate REGIS rERED AGI N F Holman J Wright III F Filed Annual Report 1-09071539 For year 2009 Do not data enter manually STA1 F OF INCORPORATION NC REGIS rERED OFFICE MAILING ADDRESS 7036 Wrightsville Avenue Suite 101 Wilmington NC 28403 REGISTFRI, DOFI ICI SIREEI ADDRESS 7036 Wrightsville Avenue Suite 101 Wilmington NC 28403 New Hanover County PRINCIPAI OFFICE rEf EPHONh NUMBER 910 256 4209 PRINCIPAL OI FICE MAILING ADDRESS PRINCIPAI OFFICE STREET ADDRESS MANAGERS/WMBERS/ORGANI/ERS 7036 Wrightsville Avenue Suite 101 Wilmington NC 28403 7036 Wrightsville Avenue Suite 101 Wibmington NC 28403 None Cypress Grove Townhomes LLC Name Roundhouse Properties ILC Name buckeye Capital LIC Title Member Title Member I itle Member Address Address Address 7036 Wrightsville Ave Suite 101 14921 USHwy 17 4 Spruce Meadow Court Wilmington NC 28403 Honpstead NC 28443 Wilton C7 06897 CERTIFICATION OF ANNUAL RFPOR7 MUST BE COMPLETED BY ALL LIMI IED LIABff ITY COMPANIES Cypres Grove 1 wnh m s LI C FORM MUS 1 BE SIGNED 13Y A MANAGLR/MEMBLR J Wright Holman III TYPE OR PRINT NAMF ANNUAL REPORT FEF $200 MAIL TO S c tart' f Stat C rpomt as Ih 05/26/2010 DATE Member TYPF OR PRINT I IrLE P st OfFc Bo 29525 R I gk NC 27626-0525 8K3552FG060 " 9I_FD 08 DEC 5 Aft 10 10 FAYETEACHEY PREVATTE crlSirR OF DEEDS PIN 0 3aSa-98-3Y88 o0 INWR COUNTY 4C �_INTu Excise Tax $0 00 Parcel Identi ica ion Number STATE OF NORTH CAROLINA COUNTY OF PENDER NON WARRANTY DEED This Non Warranty Deed is made and entered into this the 17 h day of November 2008 by and between L C Ellington and wife Debra S Ellington (hereinafter referred to as Grantor ) and Roundhouse Properties LLC a North Carolina limited liability company (hereinafter referred to as Grantee ) WITNESSETH WHEREAS Grantee has requested that Grantor convey all of their right title and interest in the real property as hereinafter described and WHEREAS Grantors do hereby consent to conveying all their right title and interest in the real property as hereinafter described to Grantee NOW THEREFORE Grantor for valuable consideration paid by Grantee the receipt of which is hereby acknowledged has and by these presents doe grant bargain sell and convey unto the Grantee in fee simple all that certain lot or parcel of land situated in Topsail Township Pender County North Carolina and being more fully described as follows Beginning at the easternmost comer of the property acquired by Veri e F Wells by deed recorded in Deed Book 211 at Page 311 of the Pender County Registry being the same property acquired by Ada Jane Hines and Gail Bowden Hines by deed recorded in Deed Book 144 at Page 94 of the Pender County Registry said comer also being the northwestern line of the former right of way of CSX Railroad (also known as the Wilmington and New Bern Railroad) said point also being the southernmost comer of the L E Howard Tract D as shown on map recorded in Map Book 17 at Page 62 of the Pender County Registry running thence from the point of BEGINNING with the extension of the northeastern line of Tract 2 described in a deed recorded in Deed Book 1144 at Page 47 of the Pender County Registry South 39 / degrees East 4 L' .y BK3552FG06I (or South 41 degrees 20 minutes 27 seconds East as shown on a plat recorded in Map Book 42 a Page 67 of the Pander County Registry using N C Grid [NAD 831 bearings) 125 feet, more or less to a point in the southeastern line of the aforesaid abandoned railroad right of way also being the northwestern line of Railroad Street, also known as Pansy Lane (24 foot public right of way) running thence with the southeastern line of the aforesaid abandoned railroad right of way and with the northwestern line of Railroad Street, also known as Pansy Lane 50 / degrees West (or South 48 degrees 38 minutes 07 seconds West as shown on said plat) 417 40 feet more or less to a point lying at the intersection of said right of way lines and the extension of the southwestern line of property acquired by Vemre F Wells by deed recorded in Deed Book 211 at Page 311 of the Fender County Registry running thence North 39 / degrees West (or North 41 degrees 20 minutes 27 seconds West as shown on plat recorded in Map Book 42 at Page 67 of the Fender County Registry using N C Grid [NAD 831 bearings) to the southernmost comer of the property acquired by Venire F Wells by deed recorded in Deed Book 211 at Page 311 of the Pender County Registry said comer also being in the northwestern line of the former right of way of said railroad running thence with the southeastern line of Tract 2 described in the deed recorded in Deed Book 1144 at Page 47 of the Pender County Registry and also with the northwestern line of said abandoned railroad right of way North 50 / degrees East (or North 48 degrees 38 minutes 07 seconds East as shown on said plat) 417 40 feet more or less to the point of BEGINNING same being 120 acres more or less TO HAVE AND TO HOLD the aforesaid tract of real property and all privileges and appurtenances thereto belonging to the Grantee in fee simple The Grantor makes no warranty express or implied as to title to the above described tract of real property IN WITNESS WHEREOF the Grantonhave caused this instrument to be duly executed and delivered on the day and year first above written aaiolduea uo°av aeaeautgy ICpmgioddp lenba ad • S IZL 96L (0I6) • gMZ DM A 170OZ OS£ 016 xva 9££L 96L auogd i �j or moll (zanoa laze) sa8ad ON 'Us3aaa2s ubulawl aaa is XHS HIA03 XV3 i aowo lsuolUd oo38mulj!&l sawaosag Iuja3sH Pas 3uamaomAua;o 3aouwudaq sugowsj 9momjo 33s3S aAUG IBUIPMO LZI 00 Z p *'uG anpiad s AVO 6)Ja409F 8 S30dd S8£ 2 HMI � IN NO X1 XU 8 1861Z 9Lun96 Wd bb 60 a-,L00 d0 dW RON 3dAl S39dd Mi X1 NIA1303N INVIS 32a � ON3S POH WV Lb 60 Ini 60H-Ld-100 180d 10 d 096 016 38 NOI, MNval NN30ON 803 State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Beverly Eaves Perdue Governor FAX COVER SHEET Date /771,!�7 To Co 61 Fax Re Dee Freeman Secretary No Pages (excl cover)_ From Jo Casmer Phone (910)796 7336 Fax (910)350 2004 .01 e5--�0.oy ov, /05 - �j des �� a/ 127 Cardmal Dnve Extension Wilmington NC 28405 (910) 796-7215 An Equal Opportunity Affirmative Action Employer EXISTING OUTLET —� STRUCTURE 0' 80, 160' ' • ' 484 WETLANDS ' - l PANSY LANE —�� -- -- -- -- 7---7 N N Smith Lea (Eta/) NSF, I 11 Roundhouse Properties, LL� \ Cypress CoOx, LLC D.B. 2887, PG: 058 D.B. ]047, PGA 318 (�! D.B. 3665, PG: 255 / I i � I I J \ UI \ 1 00 V - HOWARD AVE. Nh I I / N/F Jeremiah Reeves I I 'cbo^ P �rties DCE Holdings, LLC Roundhouse `o D.B. 2752, PG: 36 Topsoil D.B. 3546 PG: 271 P^�Peft1BS ON D.B. 1051, PG: 297 LLC D.B. 263,C ' s PG: 272 I I ' 240' r5 I / I I / / / N/F / Jerry Bums Smith D.B. 717, PG: 272 / / N/F D.B. 121, PG: 453 / N/F Jerry Bums — Smith-(Eta1 D.B. W PC; US tiwy 17 PUB�O R/W lVnR1RS) F� i / / / / / Joseph E D.B. 312, LC.W.W VICINITY MAP NOT TO SCALE i ry l „n bpi j V I � � N/F Fred R.K. Albrelght (£tal) D.B. 1793, PG: 36 / W w aIr ISM Z 0Z zw R 0 1; OC'3XZ 2 Z REVISIONS: O 51 2. REVISED 8/11/10 PER COMMENTS w 0) FROM DWO July 27, 2010. Z j a 1. REVISED JULY 8, 2010—ADDED ' U WETLANDS h SHWT BORE LOCATION v� � o o �.. ) op N co �� 0 1RN CHIEF.• M.TACKETT PAWN BY: AATACKETT/W!DOYLE iECKED BY: M.TACKETT 17E: February 1, 2010 l /O1 09608_007 PAWING: 09ti0& 007_ STORM PLMdwg 4a7.- SWM2 OF 10 lu N/F Smith Leo (Etol) D.B. 1047, PG., 318 74 72 70 68 66 64 62, 60 .0 58 a 0 F 56 0 ID m o 54 wn. r a 52, oo /\ / of 0,w / z' / - / N/F Cypress Coex, LLC D.B. 3665, PG. 255 I' PANSY LANE Roundhouse Pi D.B. 2887. I I I N/F N/F Cemetery Jerry Bums D.B. 121, PG: 453 D.S. (Eta .B. 6B4, PG: 164 443 0 0.60% 0 44, 42 40 38 36 DATUM ELiTY 35.00 Joseph Bgan Lea D.B. 312, PG. 368 REVISIONS: 2. REVISED 8/11/10 PER COMMENTS FROM DWQ July 27, 2010. 1. REVISED JULY 8, 2010—ADDED WETLANDS & SHWT BORE LOCATION FSSS16 - ?.moo .4 SEAL r: r L-4556 z' N/F Terry Roy Colton (EtaO — D.B. 543, PG: 5 b 1 �? Scale: 1'=40' HORZ. Q / Scale: 1 '=4' VERT. / rk 4W. 0. p�m N/F Fred R.K. Albreight (Etol) D.B. 1793, PG. 36 w w a w z_ z 19 N o gW£�o, oc�xz x z 3�0� w 55 a ¢ 6 z e Q0 0' m to 0 N a ao uj W) < to N N N to a N Q to to �0p vi to tG 0 ui in Ln o N n U a) 0 n h 0 In n 9) n In 0 In fop to o 0 v) in m N a N w N to t I to t 1 to tf n in 0 tf m in in o a n n tIn 80. W v �— O V) DO N N d- v Z N Q) _ 4 Q� 0 PARTY CHIEF., M.TACKETT DRAWN BY: M.TACKEI7/W.DOYLE CHECKED BY: M.TACKETT DATE- February 1, 2010 PROJECT No.: 09608_007 DRAWING. 09606-007— STORM PLAN.dwg SHEET.• SWM3 OF 10 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 1 74 74 72 j 72 70 •n - _._70 tLo t000' z:) am»> 68 _. FrZZZ -- __ se I p cl� tOp so -. +A tap Wipe _. 03a; t D 01Z0 i> 64 go nmgo 00 <m>> mZ 84 �» RZZ 62 52 60 .... ._ _. :—_ :_ — - 60 PR P S D GRADE56 ---- - 58 EXISTING GROUN --- 1 56 48.88' O 1.00x 3 52 - O.115% OF 1 B" RCP 52 �' 18•.RCP50 50 m 23.50' O M 01.25$ ! o 48 .. - __OF 18" RCP I to 48 l> 46 148 44 42 --. -__: 42 40 _. - __— 40 38 • i JB D.2R=V 0+00 0+50 1+00 p Scale.' 1=40' HORZ. Scale: 1 *-4' VERT. 0' 40' 80, 6-W TAPPIN SLEEVE 6' WV - p I S - .- a j 62 a a _ z+ at C%I I 60 Wo �- O WOD (41) ,.. E AD 5 i — '— '. rn PRO �-� � � ,. � - - -.\ / — ✓ _ GROUND - - ` — 54 - --- .. .---_ 6'WA TER LINE sz do -. -I _. amfn ui - - i m N' O +- + ____ - tD N • + a}} ! � _ to a sumr oar L � *aaa I I 0+00 0+50 1+00 - 1+50 2+00 2+50 3+00 3+50 4+00 REVISIONS: 2. REVISED 8/11/10 PER COMMENTS FROM DWO July 27, 2010. 1. REVISED JULY 8, 2010-ADDED WETLANDS do SHWT BORE LOCATION mnw to J. i Ww a w Z� 9 N N o j W N U 0(7xz z Co w a:¢ s z QO �a C A'RO�i'% \�oQ•• •,��SSIp • . 9�, o SEAL = 9 L-4556�0.`' �)fo 1; U 01 I U W W ZCl- Q ZZ CLCL - 0 --Ij �•. O N O °' v�zN CL vN M.TACKEFF DRAWN BY: M.TACKEFF/W.DOYLE CHECKED BY. M.TACKEFF DATE February 1, 2010 PMECT No.: 09608_007 DRAWING: 09608_007_ STORM P(AN.ewg SWM4 OF 10 3:1 SIDE SLOPE TO TOP OF VEGETATIVE `SHELF FOR MAIN - �, POND TEMPORARY POOL ELEV. 45.67 i TOP OF VEGETATIVE SHELF 44.5 LIMITS OF EXISTING POND-----, EXISTING OUTLET STRUCTURE REPLACE EXISTING 1.5" CONTROL PIPE WITH 2" CONTROL PIPE AT SAME ELEVATION (44.0). TOP OF STRUCTURE 44.75 INVERT 39.00 ELEVATION VIEW SHEETS OF 4'X8'X1/2" EXTERIOR (PRETREATED) 6"1 [SHEETS EQUIVALENT( TO EXTEND TO BOTTOM OF PERMANENT POOL) L- POSTS: MINIMUM SIZE = 4" SQUARE (PRETREATED) SET AT LEAST 3' INTO THE GROUND SHEETS OF 4'X8'X1/2" EXTERIOR (PRETREATED) OR EQUIVALENT POSTS: MINIMUM SIZE = 4" SQUARE (PRETREATED) SET AT LEAST 3' INTO THE GROUND PLAN VIEW BAFFLE DETAIL NOT TO SCALE WOODEN BAFFLE SCHEDULE ADD 3' FOR TEMP. POOL BAFFLE POST POND # ELEVATION DEPTH DEPTH (FT) (FT) (FT) B 45.67' 6.67' 9.67' --_ - 47 4.5 aF _ AREA 8E � 2 D RE: E HAND DUG L. RE:52.89 ..- - ..._ DUE TO CROSSING \ INV. --2.20 FIBER OPTIC LINES \ \ \A\ I I '` �� 2:1 SIDE SLOPE FROM NORMAL OOL ELEVATION VEGETATIVE END 1 TO BOTTOM OF m SHF.L'F-4M--- INV: 42.00 FOREBAY BOTTOM OF - ------ - _ Potp "B" MAIN POND NORMAL POOL 39.0 ELEV. 44.0 ' 37. ' 38 39 40 BOTTOM OF 41 FOREBAY 39.0 42 - -4 EX. OUT 15 --44- pl- I 47 `- 3:1 SIDE SLOPE FROM BOTTOM -OF-VEGEIATIvE_ FLOW -PATH SHELF TO ELONGATION BOTTOM OF BAFFLES (TYP.) I MAIN POND 20' Scale: 1-=20' HORZ. D' 1 20' d EX. JCT 14 3:1 SIDE SLOPE TO NORMAL POOL ELEVATION FOR FOREBAY FOREBAY AND POND SECTION N TS NOTE: 1. POND TO BE SEEDED WITH BERMUDA GRASS 2. VEGETATED SHELF TO BE PLANTED WITH WETLAND SPECIES SEE POND DETAIL PLANTING SPECIFICATIONS FOR POND "B": 1. THE VEGETATIVE/LITTORAL SHELF ABOVE THE PERMANENT NOTES: POOL ELEVATION SHALL BE PLANTED WITH A MIX OF THE FOLLOWING PLANT SPECIES; 1. POND "B" ORIGINAL DESIGN BY MICHAEL C. CHELONE GLABRA (WHITE TURTLEHEAD) GALLANT PE,PA. AS PART OF STORMWATER HIBISCUS COCCINEUS (SCARLET ROSE MALLOW) PERMIT SW8 070226 FOR CYPRESS GROVE LOBELA CARDINALIS (CARDINAL FLOWER) TOWNHOME PROJECT. A MINIMUM OF 550 PLANTS SPACED 24" TO 36" APART WITH 2. THE ONLY REVISION TO SW8 070226 IS THE EACH SPECIES ACCOUNTING FOR A OF THE PLANTS. ADDITIONAL DRAINAGE AREA & IMPERVIOUS AREA INTO POND "B", WITH NO OTHER 2. THE VEGETATIVE/LITTORAL SHELF BELOW THE PERMANENT CHANGES TO THE EXISTING PLANS. POOL ELEVATION SHALL BE PLANTED WITH A MIX OF THE FOLLOWING PLANT SPECIES; IRIS VIRGINICA (BLUE FLAG IRIS) PONTEDERIA CORDATA (PICKERELWEED) ZIZANIOPSIS MILIACEA (GIANT CUTGRASS) A MINIMUM OF 504 PLANTS SPACED 24" TO 36" APART WITH EACH SPECIES ACCOUNTING FOR A OF THE PLANTS. 3. THE SLOPES OF THE POND ABOVE THE VEGETATIVE SHELF SHALL BE PLANTED WITH CENTIPEDE GRASS. 3:1 cln3:1 c 3' .,., n OUTLET STRUCTURE DETAIL NOT TO SCALE � 'oQE 10,�,•�-y ? •a 9 . _ SEAL 56io,� NOTE: A. 24' CMP (ALUMINIUM) RISER WITH SCREEN AND SCUM BAFFLE TYP, 2_0' CONTROL PIPE AT 44,00. RISER INVERT 39,00. RIM ELEVATI❑N 45.67 SCREEN TO HAVE MINIMUM 4' X 4' ❑PENINGS. B. 12' CMP ❑UTFALL INVERT 42,00, OUTLET INV, 42.00, C. LEVEL SPREADERS TO EXTEND DOWN SLOPE, SEE LEVEL SPREADER DETAIL, D. EMERGENCY OVERFLOW WIER-5' WIDE, INV POND 'A'= 47.55. INV POND 'B'= 46.00 E. 4' EMERGENCY DRAIN AT INV 42.00 W/ GATE VALVE, F. ANTI SEEP COLLARS G. 6' ABC STONE UNDER PAD, H. 12' CONCRETE PAD 3' X 31,CAST WITH CMP BOTTOM OF CMP 6' BELOW TOP OF PAD, I, 6' RIP RAP 9' THICK, 3' ABC STONE WITH FILTER FABRIC UNDERLAYMENT, Level Spreader, Design Flow = 13.51 cfs Entrance width = 16 ft Depth = 0.6 ft End width = 3 ft Length = 20 ft Level Spreader Cross Section 2' PVC WEIR nts ACROSS E D MoWid VARIABLE' stapled in place \ Lerel III/ �I-�-� -_ MIN of spreader i-III-III-III -1 I I (-III-� I-� III-� I -III_ eprien III -III_ I I- � fi mn LTI _ i Construction Specifications, 1. The matting should be a minimum of 4 feet wide extending 6' over the lip and buried 6' deep in a vertical trench on the lower edge. The upper edge should butt against smooth cut sod and be securely held in place with closely spaced heavy duty wire staples at least 12' long, 2. Ensure that the spreader lip Is level for uniform spreading of storm runoff. 3. Construct the level spreader on undisturbed soil (not on fill), 4. Construct a 20-foot transition section from the diversion channel to blend smoothly to the width and depth of the spreader. 5. Disperse runoff from the spreader across a properly stabilized slope not to exceed 10%. Make sure the slope is sufficiently smooth to keep flow from concentrating. 6. Immeadiately after Its construction, appropriately seed and mulch the entire disturbed area of the spreader. Maintenance, 1. Inspect level spreaders after every rainfall until vegetation is established, and promptly make needed repairs. After the area has been stabilized, make periodic Inspections, and keep vegetation in a healthy, vigorous condition. TRASH RACK OF EXPANDED METAL W/ MINIMUM ❑PENING LESS THAN z , " v i tN 10 //1 1 1 1 ll1111� 4; Uj " a- d tty� %r7z m N z () N o' g LU 00Xz� REVISIONS: x z O 2. REVISED 8/11/10 PER COMMENTS 3 O U FROM DWQ July 27, 2010. a LL s 1. REVISED JULY 8, 2010-ADDED ul Z ¢ j WETLANDS do SHWT BORE LOCATION Q O Z) i 1 O v� O �^ Cn 00 N O � ( v�zLn CN C Q) O O7 zzc O ARTY CHIEF.. M.TACKETT RAWN BY: M.TACKET I•/W DOYLE HECKED BY. M.TACKETT ATE. February 1, 2010 OJ C No.: 09608_007 RAWING. 0960E_007 STORM PIAIll HEET.• SWM5 OF 10 TACK COAT 1 1/2" TYPE 1-2 2" TYPE H BINDER 1 I r' 8- ABC COMPACTED SI HEAVY DUTY PAVEMENT NTS 2" TYPE 1-2 LIGHT DUTY PAVEMENT NTS 1/4 1 1/4:1 6N BASE C❑URSE AND 2" ASPHALT ROAD TYPICAL ROAD CROSS SECTI❑N NTS NOTE JLL.IIUIN A —A U _w taAN FRAME AND GRATE TO BE STANDARD CITY OF 1MLMINGTON CAST PION FRAME AND GRATE PER SD 14-04 GRILL BASIN SD 2-02 NOT TO SCALE _ .. r-I. t -tt t 0.875 i. e 1�25� I'-1 1/Y k_L25'1 4.615' 0.1i76' SECSEC "A -Am "A-A"A-A" SECTION '8-B" MINIMUM AVERAGE WEIGHT FRAME 195 LBS MATE 145 LOS �00000�o� 00000060 B PLAN VIEW 1 GRILL BASIN CASTINGS SD 14-04 NOT TO SCALE A PL/ NOTE RING h COVER CONTACT SURFACES SHALL BE MACHINED TO INSURE EVEN BEARING OF COVER AND RING OR REQUIRED COVER MINIMUM WEIGHTS: " " 51 LBS. 120 LBS. SECTION "A -A" STANDARD MANHOLE RING & COVER SD 14-02 NOT TO SCALE PLAN FRAME, GRATE & HOOD ASS'Y I., i a• 1 .1 HOOD ELEVATION 0. PVMT 'ICK WALLS CEMENT PLASTER 3L1.1 lulN f-i—H- 5'-10' MIN, 5' - 4' PVMT, PB CURB & GUTTER LB PLAN '-6' 0,625' 1 � SECTI❑N 'B—B' NOTE: 1. 4' DEEP X 8' WIDE CONCRETE C❑PING ALL AROUND BASIN CASTING, 2. ALL CONCRETE TO BE CLASS 'A' 3, FOR CASTING DETAIL SEE SD 14-03 CATCH BASIN SD 2-01 NOT TO SCALE 75' P PP 1 1 1 N ' ' 2.12N , SECTION - LL SECTION - MM SECTION - BB 4 SECTION - PP SECTION - RR SECTION - JJ SECTION - KK REFERENCE TO NCDOT DETAIL MEL 840.n NOTE, USE TYPE 'E','F',& 'G' GRATE UNLESS OTHERWISE INDICATED CATCH BASIN CASTING FOR PRE -CAST SD 2-19 NOT TO SCALE Y { a W Z F3 N 04 3 :5 W 21 C) m X Z A 2 Z m Y O U Lu � Ni Er o Z Q 0 !A a DETAIL SHOWING TYPES OF GRATES TO BE USED ACCORDING TO WATER FLOW. 35.75' 2.75' TYPE 'G'ffE 'E' ffE 'F' 1.5' WATER FLOW SAG WATER FLOW A 00 0 A 1, CID — I — — — o0 j m 1.5' 1.5' 0.62' SECTION - BB it - WATER FLOW SAG WATER FLOW 1.75' -.11' jUL 2.25' SECTION - AA TYPE 'F'TYPE 'E'TYPE 'G' TYPE - E RAISED FLOW RROW 1/16' HIGH RAISED FLOW A 22,,7}5'' A RROW 1/16' HIGH O 1.5. I I O 2.75' ° D n 1.5' N 1.5' n 1v 1.5' 1.75' 1.5' i 1 1.75 �— 3�5.75' Ln TYPE - F win 0.88' SECTION - AA F '15-.��SECTION - AA TYPE - G+ CATCH BASIN GRATE FOR PRE -CAST SD 2-20 NOT TO SCALE 1.50'R ✓uNZ�1G ZG�O E7 v� _J N (n � N v O r Z N V S c� O h RTY CHIEF: ALTACKETT AWN BY: MJACKE7T/W.DOYLE IECKFD BY. M.TACKETT TE. February 1, 2010 'OJECT No.: 09608_007 AWING. 09608_007_ STORM PLAN.dwg IEET. SwM6 nF 10 PLASTIC METER BOX WITH CAST IRON COVER PER TOWN OF SURF CITY SPECIFICA TONS. ROW 17' MIN.--2' EXIST. GRADE CMy „ 2„ TEMPORARY L PLUG 45' io z i B `V A 314" P.E. PLAS77C 3/4" BRASS CORP. STOP 3408 (SDR9) 6" PVC/DIP WATER MAIN NOTES: A. METER BOX TO BE SUPPORTED ON BRICK OR BLOCK. B. ALL BRONZE SINGLE STRAP SERVICE CLAMP. C. METER YOKE WITH LOCK STOP 9" RISER, 5/8"x3/4". D. CONTRACTOR SHALL PURCHASE & INSTALL RADIO -READ TYPE METERS PER THE TOWN OF SURF CITY. EACH RESIDENTIAL LOT SHALL CONTAIN SEPARATE WATER AND IRRIGATION METERS, METER BOXES AND SERVICE CONNECTIONS. E. CONTRACTOR SHALL FURNISH AND INSTALL TWO METERS PER LOT, ONE DOMESTIC & ONE IRRIGATION, IF IRRIGATION IS DESIRED. STANDA.f?N ^JA1-EP ")MVICL DETAIL- . ---- -- SCALE: _ NOT 10 S(:AI F c 2 1 FINISH GRADE THRUST COLLAR 5' MIN. 1/4" STEEL PLATE MIN. COVER 3.5' 5' MIN. 3/4" THREADED STEEL RODS (TYP.) 3" 3" 3" 3" CONCRETE THRUST BLOCK ROD REQUIREMENTS (TYP•) SIZE OF 45 DEGREE BEND STATIC THRUST IN POUNDS NUMBER OF RODS REQUIRED 6" 4,328 2 8" 7,694 2 12" 17,312 2 16" 30,779 4 20" 48.091 6 24" 69,252 8 NOTES: 1. ONCE INSTALLED AND TIGHT, THE STEEL RODS AND BOLTS SHALL BE COATED WITH 2 COATS OF BITUMINOUS BASE PAINT. 2. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL JOINT BENDS. 3. TYPICAL MIN. CLEARANCE BETWEEN CONCRETE AND END OF BOLT MUST BE 3". 4. APPROVED OFFSETS CAN BE USED IN THIS APPLICATION. TYPICAL__ VERTICAL BEND I)[� I_AIL_ f BLI ,(',Al I: NOT TO SCAII r A C2.1 0.5' 6,69'DIA 5' O 0.5' 0.32' 0.5' A N 6.5'DIA � pp 0.5 11,88' MINIMUM WEIGHTS; T C N i TOP 10 LBS. - - - BOX 40 LBS. EXTENSION 40 LBS. NOTE, VALVE BOX LID NOT FOR USE IN ROADWAY LOCATIONS. HEAVY DUTY LID REQUIRED. WATER VAI-VI= CA ) I INC DETAIL__ / F SCALE: NOT To SCAI I \ (, Z. >EC I 11lN C V-RIBS B WATER A METER FRAME MINIMUM AVERAGE WEIGHT 40 LBS. 10.75" 0.2° SEC_T111IJ -D COVER MINIMUM AVERAGE WEIGHT 20 LBS. 1'-7 3/8" 9.625" N 2.25" - gg" 25' o 1.75" *.75 5.75" 5.75" V-6 5 8" 0.375" n SECT1�_N A SE_C-T111Ll--- WATER METER BOX DETAIL DETAIL- SCALE: NOT TO SCALE ALL CONCRETE SHALL BE 3,000 PSI MIN. C 2.1 TAPPING SLEEVE FLANGE NOTES: 1. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL JOINT FITTINGS. 2. SEE STANDARD THRUST BLOCKING TABLE EXISTING FOR AREA OF CONCRETE REQUIRED, 1/C2.1 MAIN TRENCH BOX Q ROAD n 1 _ II (I 5' MIN. uT Q ROAD w � I z a m 0 W TOP OF CASING PIPE „A„ �-- C -� Q ROAD 8' MIN. BORE FIT SECTION VIEW 130PI PIT _PLANVIEW LAYOUT SCHEDULE (FT.) "A" 5 6 7 8 9 10 11 12 8 9 1101 11112 rL DITCH SHOULDER OF ROAD 5' MIN 36" MINIMUM COVER EDGE OF PAVEMENT NOTE: "A" IS THE MINIMUM DISTANCE FROM THE EDGE OF PAVEMENT ALLOWABLE BY NCDOT, BASED ON THE DEPTH OF THE BORE PIT (-D-) AND A RATIO OF 1: 1 SLOPE CONTRACTOR SHALL FOLLOW NCDOT SAFETY REQUIREMENTS BY FENCING OFF OPEN PIT AND WORKING AREA. FOREPIT I�ETAII (LYRICAL) w cr a w v z 3 N N o' J Qwz NU°-', oqxz xzm?�j 3t]05$ U) s w z ¢ ii Q0 V)a � U - -- . �. -- DETAIL_ Dxx C�coSCALE: NOT TO SCALE�Obd a� ����II111111�1��\ (L ROAD SHOULDER OF ROAD \s�Iluulr rTOE OF SLOPE �� P 210 I�� w, c 36" MINIMUM SEPARATION "JILLL UADINU F'IYL PI�(0 D) WALL THICKNESS 4"-12 3/4" .188" 16" 250" 18" .250" 24" .250" 30" .312" 36" .375" 48" .500" hOPE &_-JA-CK UNDER Tr1 TC ROAD -(f JCDO_[) DF TAIL- X SCAI E: NOT TO SCALE C �1. X/ , EXIST. 8" DIP POTABLE SHORE DRIVE VALVE GATE VALVE J. RESTRAINED FITTINGS PROPOSED 8" WATER LINE 8> X_ S 1 ANI)f' M TAPPING- SLEEVE EVE AND VALVE AS`;f MBLY DETA11- _ 5 SCM E: N01 TO SCALE J� 0'W- �P > ?; S� u 86 \.P* 5' MINIMUM \-MASONRY ENCLOSURE AT EACH END OF CASING PIPE (TYP•) NOTE: ALL ENCASEMENTS SHALL EXTEND FROM DITCH LINE TO DITCH LINE IN CUT SECTIONS, 5' BEYOND THE TOE OF SLOPES IN FILL SECTIONS, AND 10' BEYOND THE EDGE OF PAVEMENT IN SECTIONS WITH NO DITCH OR FILL AREA (PER NCDOT) SPIDERS MIDDLE SPIDER (OPTIONAL) AS DIRECTED BY ENGINEER j � l NOTES. • CARRIER PIPE ENCASEMENT PIPE 1. NORMAL SPACING FOR SPIDERS IS 3 PER 18 FOOT LENGTH OF PIPE, ONE SUPPORT AT EACH END AND A SUPPORT AT 9 FOOT CENTER. 2. ENTIRE SPIDER ASSEMBLY TO BE BITUMINOUS COATED AFTER FABRICATION 3. FIELD MODIFY AS REQUIRED TO PROVIDE DESIGN SLOPE IN CAR; STAINLESS STEE ON EACH FOOT SPIDER CARRIER PIP El ELEI BORII'll C DET/',11 SCALE: NMI 10 E �C � cli O20 NN Z 0 O Z Q �C Z `` U � o0 t0 LQ m � X �oz rn U I Q) M c7) tX1 ` V U J L{ Cl::z� S ; o Cp Q'J Q) PARTY CHIEF M.7AC.Kt i7 DRAWN BY. M. rACKETT/6.00YLE CHECKED BY: M.TACKL0 OATF: f eoruory 1, 2010 PROJECT No.: 09608_OL'7 DRAWING: 09608007_ STORM PIAN.dwg SHEET: `'WV-7 10 80, • • • 1 404,WETLAND • . ' • • \�� t a • • ' ` LEGEND CONT. � R^EoPI�EE �' • LEGEND ' (FIR) EXISTING IRON ROD QSG SWEET GUM �� t \• •�� • � • 404�WETiANDS• 2' HPnt:` ' ' . • 4 • PM PARCEL IDENTIFICATION NUMBER I (EIP) EXISTING IRON PIPE '�p C Hl1i' • ` ' • aP/ PINE TREE ?In • D PROPERTY BOUNDARY I Sediment and Rewia Control Moaere • • (EIPT) EXISTING IRON PINCHED TOP �/ 2. Silt Fens. / / • • • - _ ADJOINNG PROPERTY LINES lam- BLACK JACK 1.Temporary(ravel ConsWction Entrance / Fsit. _ • ` 3. Sediment Trap. ❑—GTO TURKEY OAK' 4. Tempo aryarilPermanentseeding. `•• 1'EI�ORARY SEDII��NT FENCE (SIP) SET IRON PIPE C�� ��• LIMITS OF DISTURBANCE (L.OD)•••—_(EMN) EXISTING MAG NAIL IyObtam ail necessary permits. \ 57 PROPOSED CONTOURS I HICKORY E 2. Imtall temporary gravel construction entrance / exit • 3. Install silt fence, sediment traps.•EXLS lYD1G CONTOURS R^y RIGHT OF WAY CHERRY EE 4. Rough grade site. 5. Tostall utility connections n required. - �' TREE REQUIRING PROTECTION BENCHMARK 6. Seed and mulch areas disturbed during utility connections. - a ® 7. Complete grading and paving n designed. / PECAN �REE 8. Apply soil amendments ad sow grass seed R mulch on all wren not surfaced POWER POLE I I during tnaatruction. Reference vegetative plan. ' t, TREE LANE 9. Remove temporary sneas�sres once vegetative cover is fully established and LIMIT, OF n TEMPORARY SEDIIIIIENT TRAP (TST) SHE OVERHEAD ELECTRIC WIRE approval DISTl1R{3 ANCE r♦I from NCDENRis given. ® WA METER F— GUY WIRE ® Film CAT H BASIN Mum erasion control meawres shell be inspected ;/LIMITS OF EXI NG POND ` I �each repam,shoulno d be madthan e eweek«after SEDIPNT BASIN (SB) NIF- 7atLO LIVE OAK "in allram �prol measures rent Any epai s should b<made immediately to \ TOTAL DISTURBED Jerry Bums Smith MAY I 2. Maintain the gravel pad in a condition to prevent mud or sediment from leaving �0 11 i AREA = 6.53 AC. - D.B. 717, PG: 272 VICINITY / �/ MAP / ) the construction amretion site. This may require periodic topdrening with I inch smnc. y I CI NI T 1 IV Ar AM h fall � N 1 *Latitude N 34*22'15.34" (N 34.3709') NOTES: r 1. SEE SHEET SWM3 OF 10 FOR ALL DRAINAGE INFORMATION. / *Longitude W 77'4229.37" (W 2. POND 'B'TOBEUSED ASSEDIMENT TRApDUIIING EXISTING I 77.7082') CONSTRUCTION. ONCE CONSTRUCTION IS COMPLETE, OUTLET The latitude & longitude are taken SEDIMENT IS TO BE REMOVED AND POND RESTORED TO STRUCTURE ,� from the Hampstead Quad -Map. DESIGN ERIAWILL ONLY 8E DONE rnTHOSE AREAS SHOWN , HEREON. 1 4. THE REMAINDER OF THE SITE WILL BE CLEARED AND GRUBBED ONLY, NOT GRADED. A 1 I.C.W.W es ram , trespect a grave canstnreiwn entrance and clean it out as necessary. Immediately, remove all objectionable materials spillecl, washedor NOT TO SCALE Checks onto public insroachany& after e 3. Check sediment basins after each rainfall. Remove admRmt and restore the trap / to its original dimensions when the sediment has accumulated to one-half the \ design depth of the trap. Place the sediment that is removed to the designated disposal area and replace the contaminated pert of the gravel fitting. Check the structure fee damage from erosion or piping, periodically check the depth of the I to it is 1.5 feet below \ spillway ensure a minimum of the low point of the \ embankment Immediately fill any settlement of the embankment to slightly above design grade. Any npmp displaced ham the spillway must be replaced \ immediately. 4. Inspect sediment/silt fences at least once a week and after rainfall event Make any required tepees immediately- Should the fabric of a sediment fence \ \ / collapse, tin, decompose or become ineffective, replace it promptly., if the fabric of a sediment fence collapses, ten deco becomes itteff ' I reposes« . replace immediately with appropriate synthetic filth fabric,. Remove sediment deposits as needed to provide adequate storage volume fee the neat min rent n - and to reduce preasme on eta fencing material. 5. All disturbed areas will be reseeded rekrtlized and mulched n necessary to lly a stand of on cannot be determined two be fullyevegetative established =it] snail cover has been rob rained for are / ' year pas p� full t rang. Inspect all mulches each rainfall b cheek for rill Boson and dislocation. G i I Where erosion in witnessed, apply additional mWcic Continua insputia s, until vegetation is fully established. 4(j MIT., OF oi>ruRSANCE J i A / NIF ( \ i Roundhouse Properties, LLC I t % D.B. 3552, PG: 060LV - NIF NIF - - Cemetery NSF NSF ry _ _ - _ Smith Bum _ - Joseph Bryon Leo Terry Ray Coston (Etal) _ �•� J s D.B. 121, PG: 453 Etal �- D.B. 312, PG: 368 D.B. 543, PO: 5 h J .- / / _ D.B. 684, PG: a7 t I 1 o Jam, '. �BJ T LIMITS OF j NIF DISTURBANCE / ( Roundhouse Properties, LLC - - D. . . 060 I _ D.B. 355 2 PO• , I 5B P -4F _ - — _ _Y Y Y r r Y - ,. � Y I - - - - - - ' - - _ J _ - -` _ _ - - - - s� - i -- v / ro 20 - - wow E - -,1 - _ ,.- ._. / Y 55 b y Y Y �" Y 1' Y SIL' FENCC1 i' SILT FENCE \ / i - - k -\\ �_ - '' - - __ WOODED ARFA _ / - i �AREA ?_- ` \� SIANDARD �sR, •i T ' - - - INLET 5695 I I S " 2 75 TO 4 8� TO 28' CH T Z TV p HI PANSY LANEad 0'` A �i ' o ran 11 FU1X1R ti5E ! _ _ - g \ F ♦� __. J N 2 / NIF SG 8 TRIO 24' NLO 18' j I yam} �2 60 \ \' �\� 7Q 5&95�T T— I I cp �F - -jl l i A��� 1� II � Smith Leo (Etnl) ( Cypress NCoEx, LLC I \ Roundhouse Properties, LLC - B _ - - _ -- D.B. 1047, Po' 318 D.B. 2887, Po: 058 i °' 58 r ` b� �, P1 22- D.B. 3665, PG. 255 I 8 LO 29' I1 _ / i LO n 1 rLNCE T LO : i +�m / 2J' 1 t 04 \ S, 1 P7 M( h ARY l GRAbh I ` � ' `^: C�.N II ruliN INIIAIUI ( �IN I THIS AREA TO BE CLEARED AND GRUBBED NIF CV ONLY -'� Fired D.B.K. Albrer93. ig3 t(Etal) �,�-n��\, t;20 24- J L �• 0 22' THIS AREA TO BE CLEARED AND a ( I V GRUBBED ONLY- C OaO NN aC NO U 4i s o uuftj a1 U U Q jz c C) _ U CL br� Z O O 3 ti oLLJ 4 1.92 PI-12Aa CARO7* I \ - LO 2 - _ ` �� Co o N HOWARD AVE 66.00 - -- T0. �'if •:�ti1NE��.� $ N �1 — — — — — — t p� - - , m ` • O W " - z N To - - 4 3T° $ o ° o 0 m I N/F Jeremiah Reeves NIF I NIF NIF'\ LIMITS OF I I Roundhouse TEMPORARY DISTURBANCE J &0 o' " `.�o��HES8oi,�i (EtaQ I I Action Properties DCE Holdings, LLC ,- T.FMPOL a D.B. 2752, PG: 36 Of Topsail D.B. 3546, Po: 271 Properties, CONSTRUCTIONOF 2 D.B. 1051, PG: 297 LLC ENTRANCE w - - _ D.B. 2634, 'tea, SILT FENCE = Q� SEA 7': _= PG: 272 235'x5o' - = it"a _9 L-4556 �, ci Q) o - - - -- - - >-a K'OF UR f7 0o i'o PARTY CHIEF. M-TACKEIT in (4 —. W cc DRAWN BY. M.TACKE7T/W.DOYL£ Z CHECKED BY. ( _ (Was) -- Z 3 CIDci N o M.TACKETT DATE: P��O R _ _ g W ci ' February 1, 2010 x Z PROJECT No.: Sco%: 1"=80' �QS Z Z Om 09606 007 O U DRAWING: 09608_007- STORM PLAN ding 0' 80' 160' 240' R VI I Q 0 aUd SHEET REVISED JLY 8, 2010-ADDED U �I/I/�/�Q O� 1 O WETLANDS& SHWT BORE LOCATION r I� l v/ V 1 iW W j 0:0 wI Z Th NOTES: GROUND 1. WIRE SHALL BE A MINIMUM OF 32' IN WIDTH AND SHAL4 HAVE A MINIMUM OF 6 LINE WIRES W/12 STAY SPACING 2. FILTER FABRIC SHALL BE A MINIMUM OF 36' IN WIDTH AND SHALL BE FASTENED ADEQUATELY TO THE WIRE AS DIRECTED BY THE ENGINEER 3. STEEL POSTS SHALL BE 5' 0' IN HEIGHT AND BE OF SELF FASTENER ANGLE STEEL TYPE 6• MIN. STEEL POST ANCHOR FILTER FABRIC AS DIRECTED BY THE ENI TEMPORARY SEDIMENT FENCE .TER FABRIC ALL SLOPE. 6• NERGY DISSIPATER ELEVATION SUPPORT WIRE FILTER FABRIC 9511 STANDARD PROCTOR 1' MAX SPILLWAY HEIGHT POST 18" DEEP MIN. A6TM CAD ,,,-CLASS •A' RIP -RAP ENERGY DISSIPATOR MIN. SECTION FILTER FABRIC SFDIMA, _i !.:�i=OUTLFT- z ONE FOOT FOR EAC INCH OF TRUNK DIA. 16' MIN. WIDTH 0 11 of l DEAD TREES & SCRUB GROWTH ") SHALL BE CUT FLUSH WITH ADJACENT GRADE. NO GRUBBING ALLOWED UNDER DRIP LINE. REMOVE ALL BARRIERS UPON COMPLETION OF PROJECT NOTES: 1. BARRIERS SHALL EXTEND AROUND TRUNK AS SHOWN AND SHALL ENCOMPASS TREE WITH A RADIUS OF NO LESS THAN ONE FOOT (1') FOR EVERY ONE INCH (1') OF TRUNK DIAMETER. 2. ALL BARRIERS SHALL BE INSTALL PRIOR TO GRADING. 3. BARRIER POST SHALL BE CONSTRUCTED FROM 2%4' STANDARDS, SILT FENCING ECT. 4. NO FILL OR GRUBBING IS PERMITTED IN THE PROTECTED ROOT ZONE. 5. REMOVE ALL BARRIERS UPON COMPLETION OF PROJECT AND FILL POST HOLES. 6. TREE PROTECTION SHALL BE PLACED AROUND ALL TREES 4' IN DIAMETER AND LARGER WITHIN 25 FEET OF THE PROPOSED ROADWAY BACK OF CURB. I?I PROW FC !'ION *NOTES*: 113A 5 7 paragraph 2 & 3 General Statute ( ). 1. Pursuant to Ge P 9 P ( ) the angle for graded slopes and fills shall be no greater than the angle that can be retained by vegetative cover or other adequate erosion -control devices or structures. In any event, slopes left exposed will, within 21 calendar days of completion of any phase of grading, be planted or otherwise provided with temporary ground cover, devices or structures sufficient to restrain erosion. Permanent ground cover will be provided for all disturbed areas within 15 working days or no more than 90 calendar days. 2. All erosion measures are based on information in the NCDENR Erosion and Sediment Control Planning and Design Manual dated September 1, 1998 book number 6498. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE EXI '-----•" METAL POSTS 2•-0• IN GROUND GALVANIZED HARDWARE WIRE EXTENDS TO TOP OF BOX 57 WASHED STONE PLACID TO A HEIGHT OF IY-18• MINIMUM ABOVE TOP OF BOX STANDARD DROP _INLET YARD INLET PROTECTION 12" MIN. OF NCDOT #5 OR #57 WASHED STONE 3600 cu ft / acre CROSS SECTION TEMPORARY SEDIMENT TRAP DESIGNED REFER TO NCDENR SEDIMENTATION MANUAL SEC 6.6 SETTLED OVERFILL 6" TOP FOR SETTLEM 21" min. , 5' max. fill FILTER FABRIC 4' min. 1 3' min. 1 f l STONE SECTION CONSTFUCTION SPECIFICATION 1. CLEAR, GRUB AND STRIP THE AREA UNDER THE EMBANKMENT OF ALL VEGETATION AND ROOT MAT. REMOVE ALL SURFACE SOIL CONTAINING HIGH AMOUNTS OF ORGANIC MATTER AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL ALL OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL AREA 2. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY VEGETATION, ORGANIC MATTER AND OTHER OBJECTIONABLE MATERIAL PLACE THE FILL IN LIFTS NOT TO EXCEED 9 INCHES AND MACHINE COMPACT IT, OVER FILL THE EMBANKMENT 6 INCHES TO ALLOW FOR SETTLEMENT. 3. CONSTRUCT THE OUTLET SECTION IN THE EMBANKMENT. PROTECT THE CONNECTION BETWEEN THE RIPRAP AND THE SOIL FROM PIPING BY USING FILTER FABRIC OR A KEYWAY CUTOFF TRENCH BETWEEN THE RIPRAP STRUCTURE AND THE SOIL A) PLACE THE FILTER FABRIC BETWEEN THE RIPRAP AND SOIL EXTEND THE FABRIC ACROSS THE SPILLWAY FOUNDATION AND SIDES TO THE TOP OF THE DAM; OR B) EXCAVATE A KEYWAY TRENCH ALONG THE CENTERLINE OF THE SPILLWAY FOUNDATION EXTENDING UP THE SIDES TO THE HEIGHT OF THE DAM. THE TRENCH SHOULD BE AT LEAST 2 FT DEEP AND 2 FT WIDE WITH 1:1 SIDE SLOPES. 4. CLEAR THE POND AREA BELOW THE ELEVATION OF THE CREST OF THE SPILLWAY TO FACILITATE SEDIMENT CLEANOUT. 5. ALL CUT AND FILL SLOPES SHOULD BE 2:1 OR FLATTER SEEDING MIXTURE SPECIES RATE (LB/ACRE) TALL FESCUE 80 PENSACOLA BAHIAGRASS 50 KOBE LESPEDEZA 40 SEEDING DATES TIME BEST POSSIBLE EARLY SPRING FEB. 15 - MAR, 20 FEB, 15 - APR. 30 FALL SEPT. 1 - SEPT. 30 SEPT. 1 - OCT. 31 NURSE PLANTS BETWEEN APR, 15 AND AUG. 15, ADD 10 LB/ACRE GERMAN MILLET OR 15 LB/ACRE SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUG. 15, ADD 25 LB/ACRE RYE (GRAIN). SOIL AMENDMENTS APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 3,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER. UL H APPLY 4,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCH. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, ROVING, OR BY CRIMPING WITH A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE IF GROWTH IS LESS THAN FULLY ADEQUATE, REFERTILIZE IN THE SECOND YEAR ACCORDING TO SOIL TESTS OR TOPDRESS WITH 500 LB/ACRE 10-10-10 FERTILIZER. RESEED, FERTILIZE, AND MULCH DAMAGED AREA IMMEDIATELY. PERMANENT SEEDING SCHEDULE 2:1 side slope max. 1:1 side slope max. FILTER FABRIC NATURAL GROUND DESIGN OF DRAINAGE AREA SPILLWAY WEIR LENGTH (ACRES) (Fr) 1 4.0 2 6.0 3 8.0 4 10.0 5 12.0 EMERGENCY BYPASS 6" BELOW SETTLED TOP OF DAM 6. ENSURE THAT THE STONE SECTION OF THE EMBANKMENT HAS A MINIMUM BOTTOM WIDTH OF 3 FEET AND MAXIMUM SIDE SLOPES OF 1:1 THAT EXTEND T THE BOTTOM OF THE SPILLWAY SECTION. 7. CONSTRUCT THE MINIMUM FINISHED STONE SPILLWAY BOTTOM WIDTH, AS SHOWN ON THE PLANS, WITH 2:1 SIDE SLOPES EXTENDING TO THE TOP OF THE OVER FILLED EMBANKMENT. KEEP THE THICKNESS OF THE SIDES OF THE SPILLWAY OUTLET STRUCTURE AT A MINIMUM OF 21 INCHES. THE WEIR MUST BE LEVEL AND CONSTUCTED TO GRADE TO ASSURE DESIGN CAPACITY. 8. MATERIAL USED IN THE STONE SECTION SHOULD BE A WELL -GRADED MIXTURE OF STONE WITH A d50 SIZE OF 9 INCHES (CLASS B EROSION CONTROL STONE IS RECOMMENDED) AND A MAXIMUM STONE SIZE OF 14 INCHES. THE STONE MAY BE MACHINE PLACED AND THE SMALLER STONES WORKED INTO THE VOIDS OF THE LARGER STONES. THE STONE SHOULD BE HARD, ANGULAR AND HIGHLY WEATHER RESISTANT. 9. ENSURE THAT THE STONE SPILLWAY OUTLET SECTION EXTENDS DOWNSTREAM PAST THE TOE OF THE EMBANKMENT UNTIL STABLE CONDITIONS ARE REACHED AND OUTLET VELOCITY IS ACCEPTABLE FOR THE RECEIVING STREAM. KEEP THE EDGES OF THE STONE OUTLET SECTION FLUSH WITH THE SURROUNDING GROUND AND SHAPE THE CENTER TO CONFINE THE OUTFLOW STREAM. 10. DIRECT EMERGENCY BYPASS TO NATURAL, STABLE AREAS. LOCATE BYPASS OUTLETS SO THAT FLOW WILL NOT DAMAGE THE EMBANKMENT. 11. STABILIZE THE EMBANKMENT AND ALL DISTURBED AREAS ABOVE THE SEDIMENT POOL AND DOWNSTREAM FROM THE TRAP IMMEDIATELY AFTER CONSTRUCTION. 12. SHOW THE DISTANCE FROM THE TOP OF THE SPILLWAY TO THE SEDIMENT CLEANOUT LEVEL (ONE HALF THE DESIGN DEPTH) ON THE PLANS AND MARK IT IN THE FIELD. SEEDBED PREPARATION: RIP THE AREA TO BE SEEDED TO A MINIMUM DEPTH OF 4-6 INCHES. REMOVE ALL LOOSE ROCK, ROOTS, ETC. LEAVING SURFACE SMOOTH AND UNIFORM. TEMPORARY SEEDING SCHEDULE: SEED MIXTURES PLANTING RATE/ACRE PLANTING DATES GERMAN MILLET 50 LBS/AC APR 15 TO AUG 15 RYE GRAIN & 120 LBS/AC AUG 15 TO APR 15 KOBE LESPEDEZA* 50 LBS/AC *OMIT KOBE LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE. SOIL AMENDMENTS: AGRICULTURAL LIMESTONE 2000 LBS/AC, FERTILIZER 750 LBS/AC MULCH: GRAIN STRAW 2500 LBS/AC PROVIDE FRESH, CLEAN, NEW -CROP GRASS SEED COMPLYING WITH TOLERANCE FOR PURITY AND GERMINATION ESTABLISHED BY OFFICIAL SEED ANALYSTS OF NORTH AMERICA. ANCHOR GRAIN STRAW MULCH MATERIAL BY TACKING WITH ASPHALT, NETTING OR ROVING OR CRIMPING WITH A MULCH ANCHORING TOOL. HYDROSEEDING: MIX SPECIFIED SEED, FERTILIZER AND PULVERIZED MULCH IN WATER, USING EQUIPMENT SPECIFICALLY DESIGNED FOR HYDROSEEDING APPLICATIONS. CONTINUE MIXING INTO A HOMOGENEOUS SLURRY SUITABLE FOR HYDRAULIC APPLICATION. APPLY SLURRY UNIFORMLY TO ALL AREAS TO BE SEEDED. RATE OF APPLICATION SHALL BE THAT REQUIRED TO OBTAIN SPECIFIED SOWING RATE. TEMPORARY SEEDING SCHEDULE EARTH BERM BOTTOM ANCHORED WITH STAPLES •.. i�'..i tcy�7 STEEL POST CARO���i 0"�FESS% /may L ,y 4 SEAL �; 7 •r I -A Fkc JUTE NETTING JUTE SUPPORTED WITH TOP HARE BETWEEN STEEL POSTS PERSPECTIVE PROTECT WEIR WITH FILTER 5' rRETRIEVAL MER (�') FABRIC AND RIP -RAP I ROPE IIEI1 A` SEDIMENT PIT JUTE NETTING (TYPICAL) a FILTER FABRIC 3� - - -6'_ PVC - - - 5'x3'xl8' NOTES: V STONE APRON 1. USE FOR DRAINAGE AREAS NOT EXCEEDING 5 (FIVE) ACRES. 2. EARTH BERM SHALL BE STABILIZED w/SEEDING ACCORDING TO TOWN SPECIFICATIONS. DESIGN OF SPILLWAYS DRAINAGE AREA WEIR LENGTHI (ACRES) (FT) 1 4.0 2 6.0 3 8.0 4 10.0 5 12.0 1 DIMENSIONS SHOWN ARE MINIMUM FILTER FABRIC LENGTH WEIR DETAIL LINE WEIR WITH /- RIP -RAP I I WEIR LENGTH TOP OF DAM DITCH AND BURY FILTER FABRIC EDGE (MIN. 12' OF FABRIC) MAINTENANCE INSPECT TEMPORARY SEDIMENT TRAPS AND EMPTY SKIMMER OF ALL DEBRIS AFTER EACH PERIOD OF SIGNIFICANT RAINFALL REMOVE SEDIMENT AND RESTORE TRAP TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN A DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING. CHECK THE STRUCTURE FOR DAMAGE FROM EROSION OR PIPING. PERIODICALLY CHECK THE DEPTH OF THE SPILLWAY TO ENSURE IT IS A MINIMUM OF 1.5 FT BELOW THE LOW POINT OF THE EMBANKMENT. IMMEDIATELY FILL ANY SETTLEMENT OF THE EMBANKMENT TO SLIGHTLY ABOVE DESIGN GRADE. ANY RIP RAP DISPLACED FROM THE SPILLWAY MUST BE REPLACED IMMEDIATELY. STABILIZE THE EMBANKMENT AND ALL DISTURBED AREAS ABOVE THE SEDIMENT POOL AND DOWNSTREAM FROM THE TRAP IMMEDIATELY AFTER CONSTRUCTION WITH SEEDING. SEDIME.N T BASIN CAR077/i - -- - SEDIMENT BASIN (SBY1) `�rO qw�FE$$%p �� Z Wet Pond 'B' to be used as Sediment A AEosin during construction. W7Drainage Area = 7.72 Acres .Q = 33.50 cfs (7.75i*O.56c*7.72ac)%��.� Req. Surface Area 14,573 SF Storage Volume = 13.896 CF .fN ,.Req. � S a: wDesign Area at Bottom - 6,146 SF Design Area at Top = 15,306 SF A/ II11 \ WV1 to W z z ao N (-I i Design Storage Volume = 48,657 CF rn Design Size of Bottom =see Wet Pond � W x Z detail Design Size at Top = see Wet Pond O Q O LL = Z DO Detail �S ti O U S Design Depth = 5' r co 7 a LL s Weir Length = 5' ��� W Z cc ie O Cn a no O a V _J O DO CN I�^ CN v Q U N �Z 07 Q� o y c.p Q N, PARTY CHIEF.. W TACKETT DRAWN BY: M.TACKEIT/WDOYLE CHECKED BY.- M.TACKETT DATE: February 1, 2010 PROJECT No.: 09608_007 DRAWING: 09606_007_ STORM PLAN.dwg SWM9 OF 10 80' -to,• too i to. too t �\� •,. .�•J/�.,;�>' ' 'I / .at��y;. •' •',•', •',.•'.•,.•,.;,, I GPO •/' ,� II I , • • ' ' • "�A• • • , , ' ' ' '; • ' • ; ; • • ' • ' ' ' • • ' • ' ' to �- �' --- ill I .• .• .•' .•,.• ;•.• •' - I • . • ' ; : • ' : • ' : • ; : • ' . • •: • ' ' ' ; : ; ' : 404 werGAi4D�; • ' . ; NI / f I • . • ' . • ' ' '4od:WEiLAnR�. ' . • ' . • ' ' ' . Jerry D. Randall (Etol) / • to -' • •. • ' . • ' . D.B. 509, PG 156 \ � ,`1, ;.• •• • to. A4 to. ,• too NIF �(� i • ' .. • ' Roundhouse , • , . Jerry Bums Smith I / i \ : ' • • ' D.B. 3582, z • '; , . .. ' D.B. 717, PG 272 to. � A � .40A.WEI1J�MdS / N14F/ / / \ ,. Nam- I� I A I m� tttt 4preea Cow. GtC j;t:1NIF Terry Ray Coston (Etol) / o� N/F Joseph Bryan Leo D.B. 543, PG: 5 ,� / Joek Ingram N/F >° Fr8 D.B. 312, PG: J66 / t D.B. 19J, PG: 489 D.B. 1221 453 etery �Qf S �� i \ I I I I I I I I i I I I I I Scale: 1 "=80' 0' 80' 160, 240' .� a �M '.-O _ ___ -__ _� .r •�.i tears pie a _a z _ _ _ �. - i .Z�IIbL ry X../hL LH. i Jr- eta �i ii iuuwrr­ $- 11i�i`.k f/%l4f/r s �--_ QI�►i/1J�1 - - - - - . a 3lsr � Y ii�uiiiii - Zvi ,.•a l •'" . NIF E C Smith Leo (Etal) \ \ D.B. 1047. PG 318 \ \ \ \ � Cy�sC %-.LLC I A D.B. 36 PG: 255 N/F LLC M dRoundh O a D.B. D.e. z8e7, W HOWARD AVE F_ AID p ��eii try � N I I I o I Ilk xh 1 I ts • sa_ UW ry I L e m o0 O II J- Q1 — - V-1414-7 OY 17 -- vs -- T 1 1 J (v00S) _ Oa rra A, Ar / NIP P R-K Albreight (Etal) ).B. 1793, PG. 36 a•u- LC.WW VICINITY MAP NOT TO SCALE LEGEND (EIR) EXISTING IRON ROD (EIP) IXIS7ING IRON PIPE (EIPT) EXISTING IRON PINCHED TOP (SIP) SET IRON PIPE (EMN) EXISTING MAG NAIL —52— EXISTING CONTOUR LINE W/ELEV. R/W RIGHT OF WAY — — LINE NOT SURVEYED BENCHMARK POWER POLE � ffE OVERHEAD ELECTRIC WIRE E GUY MIRE OLD LAE OAK OSG SWEET GUM PI PINE TREE O"" BLACK JACK OAK GTO TURKEY OAK HICKORY TREE CHERRY TREE ® PECAN TREE J TREE LINE ® WATER METER ® CATCH BASIN HEBSRO'/ 4 SEAL L-4556 �• /D z 0 Z 0 U Z W v� O O � op N O ---- v QZ N (^ C O CL_ ^�^ iRE`C`Tr7 v o JUL 0 9 2010 PARTY CHIEF. M.TACKETT DRAWN BY: M.TACKETT/WDOnE -- --- uj W w CHECKED BY M.TACKETT _ L7 CMN S W R Lj a a4TE • February 1, 2010 Z x Z PROJECT No.: 09608_007 DRAWING: 09608_007- STORM PLO.de9 J O U REVISIONS: tn�liu-a w Z Cr> SHEET REVISED JULY 8. 2010-ADDM 5o 5_ U c �/�/A A 0 O C 1 O YY /VI r I WETLANDS dt SHWT BORE LOCATION .J Ad 6£ MZI, LOOMM u6p u0lslnaJ anoj6 ssajdAo� 8 17 16 54r,4 3 2 1 D C Ill I _.._.._ ._.._.._.._ �, j I I I � • i IL I i 14 ( 77 47 is z►—CLOS add / / \ / /, Q d5 00 9 ` \ i i — S=3 d ` \ T // i — - I / w,• V Tog qw loa weer iI vJry \ I OS = dd / ' d.ki N tS'LL l �, T ?— l — ,£0'8Z ! d!1 10401 f8�'96Z M 11�5141 N 4) Ln M$I 30t1d �Ib'13Q 33S '33d31f10 H1IM EdnO 3H1 31Vd J130d d9 A1133dia W31SAS NOI133-1-100 631dMW2101.S 3H1 01 SONIQ-InE -13d 30 aV36 3H1 W06J S6311n0 HWn3d '31DN N �o O N Fz LO (J 4 co 20 I LD V) 61 v I J N I � 00 71 1 � zr� / � �-- ail/• I � � r : �, �7� T � =4 � yam'•,-! % � C\ -- F 27 CP Y SEC ! L f%t/ $ a% - — — — — -6Y— _ _ �— —• -\ 1 I I T:yECG,q�',� C._J /`Gil For e'ypre-s.s S l4f �.ti � 5-0041, 0 341 is _ 9 �I S= �)24 J»fit' l> �r1a All . _ �y9 9 SEAL —_ 9 L-4556 1r t', SUR.• LEE ZPG ` 1 v AV W N Lov I ' 1 • I _ • N ; Z^ I I u 4 , u x � Z O = N R o Z Z ti W G m H w N O 4 t 2 Y 1 w > O W C w Y r 4 C a Li � 4 � Lj K A �l O H a I W N J r > W J Z q O ti W n I r APPROVED 4"' NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DIVISION OF WATER QUALITY 3,/!4/v7 L/) W M oZ pCot�- C-4 V z z J = V J W .. W i CL U Q � a o co N v cd c b �zo � '� 2 u o• co C cQ • 1 Go V c a z can N cd N C o n, ,� •_ Ln o . V WraO a v\ W N VI U m 0 I. Q cc uj {ZIT tn A 8 7 16 5 lq% 4 I 3 2 Wd Ll LtaL LOOTJVLJE u6p uosina; 9na6 sea1dA7 I I N ,1� all me I N J � to I AV \ \ ID10i ,22'96Z M „�S,I N _t �. MS 39Vd _1Id13Q 33S '33d31(10 H1IM adm 3H1 31VK31bd dg �,_U33VI W31SAS NOI133-1-103 �131VMWaOiS 3H1 01 S3NIQ3If1H 33d 30 NV3d 3H1 WONJ S831ino gwn-ld :31ON 7 0 LU 3-J 47 3: 48 as M w 51 Ln O 52 N O 75 't 0 Z (,tJ 00 N O r� V n 1 r. 7 n 5 ,bG 1juy j „�:S, L6.lt S 0 N (D M c0 co i� O 00 t�)M W fi0 A3 Toe IA 04 A ! W • N N n ON Z 0\ � I I ' I I I - _. ❑ a u Z ai Y W % x f~ = w , W q L1 Z to Q O Ib Q W ❑ Q W W � w H G N Z per,, V Z J y� 1QQ7 2 �I w J F 0 W � � Q m ❑ 0- ❑ Ix N H d N W J O N W F ✓&41 29 APPROVED eAb NORTH CAROUNA BCO OISANX MANAGEMENT�1 DMSION OF WIM QLKff 3/1L /07 3 I 2 w OZ M O N N (� V Z Z J = J W W Q CL off LU bb.0 h �Q W � O M \ tJ V N N �w� U to V • \ Qi Q� O M •� �i.l Q J Q VI 0 u m ., w 0 u w 0 LU Vf r A 1 >,recea 3/:=a 5 4„ 4 13 I 2 I 1 B A )-ur<, rune" �s s�G pL r`i jvs -ey riE cL.�I )?,K CoZOV P �d� GytoF'LSS sT�T,�,✓ Au- 0TyE� 16 A-rl Z. Z_ l4lU �S S FiOwn% c ,iJ 7-bE_ I 30' 0' 30' 60' 90' - 30' A ,y9.9 L.4556 EE\�Pv" \ Q © CO (D fl- CD m CO m cr 45 23. 00 40 0+00 1 + 0 0 2+00 2+87 � RAUUC GRADE UNE N � � - FINIS ED GRADE r- EXISTING RAD a) .r 3LF OF C9P�4 ]24.08LF OF 900 �- _ _ 111.03E OF C900 25.85LF OF C 24" RCP � O�i;C. 2 'RCP 27' RCP L �i 7 POND "A" LINK STATISTICS- RCP, n=.01 T LINK ID UPSTRM ID DWNSTRM ID Q LENGTH SLOPE_ INV UP NV DOWN 7 7 8 16.393 75.9 0.15 43.32 43.21 4 4 7 7.327 80.5 0.94 44.08 43.32 6 6 7 4.565 81.3 0.52 44.75 44.32 3 3 4 4.636 23.9 0.29 44.65 44.58 5 5 6 2.218 24.1 0.19 44.79 44.76 2 1 3 1.775 70.7 0.3 45.12 44.9 1 2 1 0.872 24.1 0.29 45.19 45.12 POND "B" LINK STATISTICS- RCP, n=.012 LINK ID UPSTRM ID DWNSTRM ID Q LENGTH SLOPE INV UP NV DOWN 13 14 15 12.55 25.9 0.15 43.34 43.3 12 13 14 12.55 111 0.15 43.51 43.34 _ 9 10 13 9.63 100.6 0.06 44.37 43.76 11 12 13 2.93 124 0.15 43.94 43.76 8 9 10 4.96 22.8 0.15 44.4 44.37 10 11 12 2.68 23.6 0.15 43.98 43.94 m m m C� 0' r. � (`"' co- EXISTING GRADE 4c 22.. HYD GRAD UNE NISHED 'LF OF C900 100.61LF C900 � 24' CID 24' 24' RCP c4 0:15% ;j t? 0.60% _ 40 0+Q0 (.D DE Ln 1 +00 1 + 25 Q U N u u E m W 3 O M O t-, V Z � V Z LCL u w W i u N W a U Lij T N I 1 6 5 4 3 2 I 1 8I b 5 4 3 2nor 1 HE = 50 LAI - - 366 SF D a z o 1q0 OUTLET STRUCTURE DETAIL 6 z z - A77 Oro dOH LZ .30 NOT TO SCALE .11 d1 EO [ D I I /- rn N� \ BERM ! .Iq i [ D m� obi ERRESTRI BE u ���9.3 A I �C ELF. 48.D5 ERR IA N TOP) n w (^) 'T R RI BE (BOT) o0 00 v I i E. 6 ATIC 4' AOU IC E N ( P) / CONTROL PIRG ELL aam 0 A H n 9 ELE. V EL H E W _ • 4 i � �, DND BOTTON � / -^--� �.O � V .fLE. 39 / �+ - I¢i// ^+] U G F ERR EL 42.0 A ELE. 45.38 CIOi' OJ NOTE: zk A. 24• CMP (ALUMINIUM) RISER WITH SCREEN AND SCUM BAFFLE TYP. 1,54 CONTROL PIPE AT 44.00. RISER INVERT ' l ♦ ♦ 3 W Q r - ♦ _ _ _ / \' 39.00, RIM ELEVATION 44.75 SCREEN TO HAVE MINIMUM 4' X ♦ p� j ! ! 1 \ I♦ / �\ % 4' OPENINGS. CT / ♦ 3 r I' 30 /'� 0 0 ��0 B. 12' CMP OUTFALL INVERT 42.00, OUTLET INV. 42.00. a C w1 / \ C. LEVEL SPREADERS TO EXTEND DOWN SLOPE. SEE LEVEL �m \*301 01 30' 6 901 Ta O M \\ SPREADER DETAIL. H ":] er I 111 301 \� / / D. EMERGENCY OVERFLOW WIER-5' WIDE. INV POND 'A'= oC ♦ z ao j ' 47.55. INV POND 'B 47.84 brr� 1 w/ 11 __ E. 4' EMERGENCY DRAIN AT INV 42.00 W/ GATE VALVE. 'v r = h N \ F. ANTI SEEP COLLARS ��� ~ G. 6' ABC STONE UNDER PAD. _ (� z H. 12' CONCRETE PAD 3' X 3'.CAST WITH CMP BOTTOM OF V z z II �' CMP 6' BELOW TOP OF PAD. POND I 6 RIP RAP 9' THICK, 3' ABC STONE WITH FILTER FABRIC "All UNDERLAYMENT. V 1 uWJ POND,A �ON� POND NOTES: w - Q )7 7) � a- A•�. I}�T rp,,I ,SR POND „A„ GROSS DIMENSIONS 247' X 75' �" W .R•orl TO O Cown YOI, TM RpRI RYLOMO IV � �CTION'A-A Tsa+ B-B LITTORAL SHELVES TO BE PLANTED WITH W 4 4NK[TIR:,. �1a4 d WETLAND SPECIES SUCH AS THE FOLLOWING "'R ► A aa A 1 ACORUS CALAMUS SWEET FLAG i n• • wtl HYDROCOTYLE UM LLATE WAT R PENNYWORT) - -- R !'lEtl SE t'lAtl 7/0 - r so• wnc NARrm I.. � OonON or w1RA I -I - AUY a idol our Rnrrp �uonm urr .orz. SECTION 'A -A• '.' O'lIC .:,n °,.T uTI I IRIS VERSICOLOR BLUE FLAG) 0 5 A CO R TACT IRIIRKRI �KMT4 - j m 120 ul 1•-111 GUTTER PLUMBING DETAIL �=�� �p/Vb S��- f LA.✓ S �� 62ozlP F/o� R r INSTAL MANIFOLDT TSYSTEM IN REAR (p ✓r �.�,(1%[, D % y�� �Y/ 7,6to NIS1 IS S% /LL ,4S AfS/ 6,</�� �L - l%(.✓.✓ O� / /j�L� (�•�/��✓S ,`` � J��1�'% ►• •I PLAN VIEW a• OF BUILDINGS • � C/o y4L 0 .- Z- GRI BASIN CASTINGS r:0 \\ SD 14-04 �/Rpl NI ifJ1[ • - Q J. SECTION 'A -A' ' o < STANDARD MANHOLE RING & COVER I -Z;a Sg656 p SD 14-02 = '. < �fJam• .,,, NOT TO WAlf ///�•Ii�HAEL `�II^' TRASH RACK OF EXPANDED METAL W/ �CURB GRAD : - 0.625• ---- --- 11 MINIMUM OPENING LESS THAN !'. G PVMT - tP 11, I '^ BRICK WALLS 3/4' CEMENT PLASTER Level Soreader: IrtAI SMDv NG NIG OF RATES W. Desi n Flow = 13.51 cfs Entrance width = 16 ft P Be USED ACC&DIMG TO WA PLOW. 35.7 275' g Ali y (TYPE •G'ITYPE •E't;YPE •F• 'm Depth = 0.6 ft End width = 3 ft 1'TLET 1.51 Length = 20 ft 4 ,b+0 41 SECTION - LL SECTION - MM WATER FLOW SAG WATER FLOW w A A . SECTION *A -A• H O 1' 36 DIA $ECI ❑N 'B-B' N • MIN. ���+�.111 Q c 4 ° N � PLAN l.y' 1 Z' FRAME, GRATE ► MOOD ASS'Y Level Spreader •�,,,� 2• sccnON - B ` 1' Cross Section o EuaB ► currER Q SECTION - PP LS• 0.62' SECTION - BB 2' PVC WEIR ntS AM 24 I �. 1.. ACROSS D 1, WATER FLOW SAG WATER FLOW 1.73' VARIABLE' I 36 S 1.37.� 137• SECTION - AA UulMitl K K t¢ ,\� TYPE -F' TYPE 'E' YP£ 'G' TYPE - E Rl°pIW N lQ j SECTION - AA 11 i AISj[[D FLOW P1otR I V V T,n ROV 1/16' HIGH _ 1' 6 ' ` b�4 z Q 3' SECTION - NN AISEED FLOW -111 .''I - - - - 'E 00 MIN 1 - 00 FRAME PLAN 6 , A 2.75• A OW I/16' HIGH - '�I I_I ITII IFIt �I' ��� 1� _ 275• - uTLW iftal I0I I LLL-iL.L-�I Bwk01 "'-1-1L'-I� �T4EL#J' DEEP X 8. WIDE CCiNfRETE COPING C N J 11-� I I II I I' 8' min I _ TTT 2, ALL CONCRETE TO 6E CLASS 'A• X 0.5. O II IrII -II�• ALL AROUND BASIN i:.:S'1NG � L c6 0. `P 3. FOR CASTING DETAIL SEE SO 14-03 ai .�, ENvT F 4� _ 2i2' V ° 1. 75• 4.6 ' 6' m Ly a \ O °J I .754.63' 1.7 I- 9' A .�.I.� Construction Specifications: ATCH BAS N b.0 m -- I SECTION - RR 15" t75' Ly 1. The matting should be a minimum of 4 feet wide extending 6' over SO 2-01 •-., a 9' s• the lip and buried 6' deep in a vertical trench on the lower edge. NOT TO SCALE U1j HOOD ELEVATION p75' n5 9• 069¶- I s12• 1 LSD•k The upper edge should butt against smooth cut sod and be securely - o �< SECTION 0.t9" la• 13 held in place with closely spaced heavy duty wire staples at least INLET0'7 1.30g lon CHANNEL - JJ-• 19' 1 3-S' 75' TYPE - F 1-.Si-1.1 2. Ensure that the spreader tip Is level for uniform spreading Of TEMPORARY POOL ELE/ WATER QUALITY N SECTION - KK 1. storm runoff. POND •A' - 45.38 P MQ=ar OUTLET K;K14T� SECTION - AA 3. Construct the level spreader on undisturbed soft (not on fill). 3:i 5" SINUCTuRE \ SEE DETAIL 4. Construct a 20-fOOt transition section from the diversion channel S+EEt 3 ° ♦`� SECTION - AA to blend smoothly to the width and depth of the spreader. 6: I NOTE: USE TYPE 'E'.'F•,► •c• GRATE UNLESS K' S. Disperse runoff from the sprender across n properly stabilized 6 T LEVEL OTHERWISE INDICATED -I Y '2• PERNA MIT POOL EL N.Oa SPREADER CATCH BASIN CASTINC FOR PRE -CAST TYPE - G slope not to exceed 10%. Make sure the slope is sufficiently smooth TERRESTRIAL ti' SEE DETAIL SD 2-19 CATCH BASIN GRATE FOR PRE -CAST to keep flow from concentrating. BENCH WATER 6:1 ti1 _ NOT r0 SCALE SD 2-20 6. Immeadiatety after its construction, appropriately seed and mutch OAULITY ?� 390o ti NOT TO SCALE the entire disturbed area of the spreader. AQUATIC INV _. BENCH INV 42.0 / Maintenance: 4200 } I 1. Inspect level spreaders after every rainfall unt:t vegetation is established, and promptly make needed repairs. After the area has been stabilized, make periodic inspections, and keep vegetation in a healthy, vigorous condition. FOREBAY AND POND SECTION ✓'JL NOTE: NTSIr 1. POND TO BE SEEDED MTN BERWJOA GRASS 2. VEGETATED SHELF TO BE PLAN fEJ arm WETLANp SPECIES SEE POND DII g 7 6 5 4 3 2 1 _, �::: �I:�.ro r�: yl�n nqn 3'14'^b'7 ^• 1 17 43 AM