Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW8060806_HISTORICAL FILE_20060922
STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO SW8 �Oho DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS wNe HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 20010 0(111 YYYYMMDD Michael Easley Governor William Ross Jr, Secretary North Carolina Department of Environment and Natural Resources Alan W Klimek P E Director Division of Water Quality Coleen H Sullins Deputy Director Division of Water Quality September 22, 2006 Mr Brian D Dodd, Member Sea View Investment Group, LLC P O Box 745 Kure Beach, NC 28449 Subject Stormwater Permit No SW8 060806, Sea View High Density Subdivision Protect, New Hanover County Dear Mr Dodd The Wilmington Regional Office received a complete Stormwater Management Permit Application for Sea View on August 2, 2006, and additional information on September 21, 2006 Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H 1000 We are forwarding Permit No SW8 060806 dated September 22, 2006, for the construction of the subject project This permit shall be effective from the date of issuance until September 22, 2016, and shall be subject to the conditions and limitations as specified therein Please note that the construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-2151 and is subject to enforcement action pursuant to NCGS 143-215 6A Please pay special attention to the Operation and Maintenance requirements in this permit Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within sixty (60) days following receipt of this permit This request must be in the form of a written petition, conforming to Chapter 150E of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P O Drawer 27447, Raleigh, NC 27611-7447 Unless such demands are made this permit shall be final and binding If you have any questions, or need additional information concerning this matter, please contact Mary Jean Naugle, or me at (910) 796-7215 Sincerely, Edward Beck Regional Supervisor Surface Water Protection Section ENB/mjn S \WQS\STORMWAT\PERMIT\060806 sep06 cc Luke Menius, Stroud Engineering Tony Roberts, New Hanover County Building Inspections Beth E Wetherill, New Hanover County Engineering Division of Coastal Management Wilmington Regional Office Central Files w N C Division of Water Quality 127 Cardinal Drive Extension (910) 796-7215 Customer Service Wilmington Regional Office Wilmington NC 28405 (910) 350-2004 Fax 1-877-623-6748 NO DEN'R State Stormwater Management Systems Permit No SW8 060806 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY SUBDIVISION DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Brian D Dodd, Member and Sea View Investment Group, LLC Sea View 637 Fort Fisher Blvd North, Kure Beach, New Hanover County FOR THE construction, operation and maintenance of one (1) underground infiltration trench in compliance with the provisions of 15A NCAC 2H 1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit This permit shall be effective from the date of issuance until September 22, 2006, and shall be subject to the following specified conditions and limitations I DESIGN STANDARDS This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data 2 This stormwater system has been approved for the management of stormwater runoff as described in Section 17 on page 3 of this permit The subdivision is permitted for nineteen (19) lots, each allowed built -upon area as follows Number of Lots Lots Numbered Built -upon area (square feet 1 8 694 8 2,4,6,10,11,13,16,18 875 10 1,3,5,7,9,12,14,15,17,19 911 The stormwater control has been designed to handle the runoff from a total of 34,000 square feet of impervious area The infiltration trench was oversized to collect a 3 inch storm water event, therefore does not require a 30 foot vegetated filter 4 The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans This permit provides no allocation for any future built - upon area Page 2 of 8 State Stormwater Management Systems Permit No SW8 060806 5 6 7 All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans The runoff from all built -upon area within the permitted drainage areas of this project must be directed into the permitted stormwater control system The following design criteria have been provided in the infiltration trench and must be maintained at design condition F b c d e f 9 i 9 m n 0 p Drainage Area, acres 1 543 acres Onsite, ft2 66,832 Offsite, ft2 0 Total Impervious Surfaces, ft2 34,000 Design Storm, inches 3 Trench Dimensions, L x W x H, ft 241 x 4 x 2 Perforated Pipe Diameter/Length 8 in dia x 241 ft Bottom Elevation, FMSL 13 Bypass Weir Elevation, FMSL 977 Stormwater pumped from storage area (located in 36" pipe) To trench Permitted Storage Volume, ft3 8485 (1200 If of 36" pipe) prior to being pumped Type of Soil Expected Infiltration Rate, in/hr Seasonal High Water Table, FMSL Time to Draw Down, hours Pump model Zoeller # 264 Receiving Stream/River Basin Stream Index Number Classification of Water Body II SCHEDULE OF COMPLIANCE Newhan 20 11 48 hours 30 gpm @ 14 ft TDH Atlantic Ocean 99-3 "SB„ 1 The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface 2 During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately 3 The facilities shall be constructed as shown on the approved plans This permit shall become void unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data Page 3 of 8 State Stormwater Management Systems Permit No SW8 060806 4 If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility 5 The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to a Semiannual scheduled inspections (every 6 months) b Sediment removal c Mowing and re -vegetation of slopes and the vegetated filter d Immediate repair of eroded areas e Maintenance of all slopes in accordance with approved plans and specifications f Debris removal and unclogging of bypass structure, filter media, flow spreader, catch basins, piping and vegetated filter g A clear access path to the outlet structure must be available at all times Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ The records will indicate the date, activity, name of person performing the work and what actions were taken Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation Any deviations from the approved plans and specifications must be noted on the Certification A modification maybe required for those deviations The certification form is included on pages 7 and 8 of this permit Access to the stormwater facilities shall be maintained via appropriate easements at all times The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below a Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc b Protect name change c Transfer of ownership d Redesign or addition to the approved amount of built -upon area or to the drainage area e Further subdivision, acquisition, lease or sale of all or part of the protect area The protect area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought f Filling in, altering, or piping of any vegetative conveyance shown on the approved plan 10 The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction 11 A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction Page 4 of 8 State Stormwater Management Systems Permit No SW8 060806 12 The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made 13 Prior to the sale of any lot, the following deed restrictions must be recorded a The following covenants are intended to ensure ongoing compliance with State Stormwater Management Permit Number SW8 060806, as issued by the Division of Water Quality under NCAC 2H 1000 b The State of North Carolina is made a beneficiary of these covenants to the extent necessary to maintain compliance with the Stormwater Management Permit c These covenants are to run with the land and be binding on all persons and parties claiming under them d The covenants pertaining to stormwater may not be altered or rescinded without the express written consent of the State of North Carolina, Division of Water Quality Alteration of the drainage as shown on the approved plans may not take place without the concurrence of the Division of Water Quality The maximum built -upon area per lot is as follows Number of Lots Lots Numbered Built -upon area (square feet 1 8 694 8 2,4,6,10,11,13,16,18 875 10 1,3,5,7,9,12,14,15,17,19 911 These allotted amounts include any built -upon area constructed within the lot property boundaries, and that portion of the right-of-way between the front lot line and the edge of the pavement Built upon area includes, but is not limited to, structures, asphalt, concrete, gravel, brick, stone, slate, coquina and parking areas, but does not include raised, open wood decking, or the water surface of swimming pools g Lots and common areas within CAMA's Area of Environmental Concern may be subject to a reduction in their allowable built -upon area due to CAMA regulations All runoff from the built -upon areas must drain into the permitted system This may be accomplished through a variety of means including a piped collection system, which ultimately discharges into the storm water facility, appropriate grading such that the built -upon surfaces drain into the storm water facility, or graded swales which collect runoff and direct it into the storm water facility, or infiltration where applicable Built -upon area in excess of the permitted amount will require a permit modification 14 A copy of the recorded deed restrictions must be submitted to the Division within 30 days of the date of recording the plat, and prior to selling lots The recorded copy must contain all of the statements above, the signature of the Permittee, the deed book number and page, date and the stamp/signature of the Register of Deeds Page 5 of 8 State Stormwater Management Systems Permit No SW8 060806 III GENERAL CONDITIONS This permit is not transferable except after notice to and approval by the Director In the event of a change of ownership, or a name change, the permittee must submit a formal permit transfer request to the Division of Water Quality, accompanied by a completed name/ownership change form, documentation from the parties involved, and other supporting materials as maybe appropriate The approval of this request will be considered on its merits and mayor may not be approved The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215 6A to 143-215 6C 3 The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction 4 In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems 5 The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility 6 The permit may be modified, revoked and reissued or terminated for cause The filing of a request for a permit modification, revocation and re -issuance or termination does not stay any permit condition 7 Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual 8 Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit 9 The permittee shall notify the Division of any name, ownership or mailing address changes within 30 days Permit issued this the twenty-second day of September 2006 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION (�A'Ib yta 4a, 00� Vr fia— n W Klimek, P E , Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number SW8 060806 Page 6 of 8 State Stormwater Management Systems Permit No SW8 060806 Sea View Stormwater Permit No SW8 060806 New Hanover Countv Designer's Certification I, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/ weekly/ full time) the construction of the protect, (Protect) for (Protect Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the protect construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications The checklist of items on page 2 of this form is included in the Certification Noted deviations from approved plans and specification Signature Registration Number Date SEAL Page 7 of 8 State Stormwater Management Systems Permit No SW8 060806 Certification Requirements 1 The drainage area to the system contains approximately the permitted acreage 2 The drainage area to the system contains no more than the permitted amount of built -upon area 3 All the built -upon area associated with the protect is graded such that the runoff drains to the system 4 All roof drains are located such that the runoff is directed into the system 5 The bypass structure elevations are per the approved plan 6 The bypass structure is located per the approved plans 7 A Trash Rack is provided on the outlet/bypass structure 8 All slopes are grassed with permanent vegetation 9 Vegetated slopes are no steeper than 3 1 10 The inlets are located per the approved plans and do not cause short-circuiting of the system 11 The permitted amounts of surface area and/or volume have been provided 12 All required design depths are provided 13 All required parts of the system are provided 14 The required system dimensions are provided per the approved plans cc NCDENR-DWQ Regional Office Permit No SW8 060806 Tony Roberts, New Hanover County Building Inspections Page 8 of 8 OFFICE USE ONLY Date Received I Fee Paid Permit Number $ Z Dl0 Azq ow Do O w eQ SO State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an ongmal I GENERAL INFORMATION 1 Applicants name (specify the name of the corporation individual etc who owns the project) Sea View Investment Group, LLC (member managed) 2 Print Owner/Signing Official s name and title (person legally responsible for facility and compliance) 3 Mailing Address for person listed in item 2 above PO Box 745 City Kure Beach State NC Zip 28449 Telephone Number ( 910 ) 612-8605 4 Project Name (subdivision, facility or establishment name - should be consistent with project name on plans specifications letters operation and maintenance agreements etc ) 5 Location of Project (street address) 637 Fort Fisher Blvd. North City Kure Beach County New Hanover 6 Directions to project (from nearest major intersection) From intersection of Dow Rd. and Fort Fisher Blvd , take Fort Fisher Blvd. north 6 blocks Project is on the left before Kure Village Way. 7 Latitude 340 00 i 28" Longitude 770 54 i 12" of project 8 Contact person who can answer questions about the project Name Luke Menws 0 Stroud Engineering Telephone Number ( 910 1 815-0775 II PERMIT INFORMATION I Specify whether project is (check one) _XNew Renewal Modification Form SWU-101 Version 3 99 Page 1 of 0 2 2006 AUG7BY 2 If this application is being submitted as the result of a renewal or modification to an existing permit list the existing permit number and its issue date (if known) 3 Specify the type of project (check one) _Low Density X High Density _Redevelop _General Permit _Other 4 Additional Project Requirements (check applicable blanks) _CAMA Major X Sedimentation/Erosion Control 404/401 Permit _NPDES Stormwater Information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748 III PROJECT INFORMATION 1 In the space provided below, summarize how stormwater will be treated Also attach a detailed narrative (one to two pages) describing stormwater management for the project The first 3" of stormwater will be collected in 36" RCP and DumDed to an infiltration trench sited in soils capable of infiltrating over 20 in/hr A detailed narrative is attached. 2 Stormwater runoff from this project drains to the Cape Fear River basin 3 Total Project Area 1.93 acres 4 Project Built Upon Area 50.9 % 5 How many drainage areas does the project have? 1 6 Complete the following information for each drainage area If there are more than two drainage areas in the project attach an additional sheet with the information for each area provided in the same format as below Basin Information Drainage Area 1 Drainage Area 2 Receiving Stream Name Atlantic ocean Receiving Stream Class SB Drainage Area 1 66832 5 F c Existing Impervious` Area 0 Proposed ImpervioustArea 34000 - % Impervious' Area (total) 50.9 f Impervious` Surface Area Drainage Area 1 Drainage Area 2 On -site Buildings 15540 On -site Streets 10100 On -site Parking 6865 On -site Sidewalks 0 Other on -site 1495 reserve Off -site 0 Total 34000 Total ` Impervious area is defined as the built upon area including, but not limited to buildings roads parking areas sidewalks gravel areas, etc C�VQ D- Form SWU-IOl Version 3 99 Page 2 of AUG 0 2 2006 BY L__ How was the off -site impervious area listed above derived? IV DEED RESTRICTIONS AND PROTECTIVE COVENANTS The following italicized deed restrictions and protective covenants are required to be recorded for all subdivisions, outparcels and future development prior to the sale of any lot If lot sizes vary significantly a table listing each lot number size and the allowable built -upon area for each lot must be provided as an attachment 1 The following covenants are intended to ensure ongoing compliance with state stormwater management permit number as issued by the Division of Water Quality These covenants may not be changed or deleted without the consent of the State 2 No more than 34000 square feet of any lot shall be covered by structures or impervious materials Impervious materials include asphalt gravel, concrete brick, stone, slate or similar material but do not include wood decking or the water surface of swimming pools 3 Swales shall not be filled in piped or altered except as necessary to provide driveway crossings 4 Built -upon area in excess of the permitted amount requires a state stormwater management permit modification prior to construction 5 All permitted runoff from outparcels or future development shall be directed into the permitted stormwater control system These connections to the stormwater control system shall be performed in a manner that maintains the integrity and performance of the system as permitted By your signature below you certify that the recorded deed restrictions and protective covenants for this project shall include all the applicable items required above that the covenants will be binding on all parties and persons claiming under them, that they will run with the land that the required covenants cannot be changed or deleted without concurrence from the State and that they will be recorded prior to the sale of any lot V SUPPLEMENT FORMS The applicable state stormwater management permit supplement form(s) listed below must be submitted for each BMP specified for this project Contact the Stormwater and General Permits Unit at (919) 733-5083 for the status and availability of these forms Form SWU-102 Wet Detention Basin Supplement Form SWU-103 Infiltration Basin Supplement Form SWU-104 Low Density Supplement Form SWU-105 Curb Outlet System Supplement Form SWU-106 Off -Site System Supplement Form SWU-107 Underground Infiltration Trench Supplement Form SWU-108 Neuse River Basin Supplement Form SWU-109 Innovative Best Management Practice Supplement ' EC �� r , Form SWU-101 Version 3 99 Page 3 of G 0 220 66 - --- - VI SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ) A complete package includes all of the items listed below The complete application package should be submitted to the appropriate DWQ Regional Office Please indicate that you have provided the following required information by initialing in the space provided next to each item Initials • Original and one copy of the Stormwater Management Permit Application Form t^ • One copy of the applicable Supplement Form(s) for each BMP • Permit application processing fee of $420 (payable to NCDENR) 4, • Detailed narrative description of stormwater treatment/management • Two copies of plans and specifications including - Development/Project name - Engineer and firm -Legend - North arrow - Scale - Revision number & date - Mean high water line - Dimensioned property/project boundary - Location map with named streets or NCSR numbers - Original contours proposed contours spot elevations finished Floor elevations - Details of roads drainage features collection systems and stormwater control measures - Wetlands delineated or a note on plans that none exist - Existing drainage (including off -site) drainage easements pipe sizes runoff calculations - Drainage areas delineated - Vegetated buffers (where required) VII AGENT AUTHORIZATION If you wish to designate authority to another individual or firm so that they may provide information on your behalf please complete this section Designated agent (individual or firm) Luke Menius @ Stroud Engineering, P A Mailing Address 102—D Cinema Drive City Wilmington Phone ( 910 ) 815-0775 VIII APPLICANT'S CERTIFICATION State NC Zip 28403 Fax ( 910 ) 815-0593 I (print or type name of person listed in General Information item 2) Brian D. Dodd, member , certify that the information included on this permit application form is to the best of my knowledge correct and that the project will be constructed in conformance with the approved plans that the required deed restrictions and protective covenants will be recorded and that the proposed project complies with the requirements of 15A NCAC 2H 1000 Signature Form SWU-101 Version 3 99 Date I' I - O (o FRECEYN 7-- Page 4 of 4 AUG 0 Z 2006 BY. - Permit No JW8 060SO(2) (to be provided by DWQ State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied for use as an anginal DWO Stormwater Management Plan Review A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details I PROJECT INFORMATION Project Name Sea View Contact Person Luke Menius @ Stroud Engineer > nlffione Number (310 ) 815-0775 For projects with multiple infiltration systems, a supplement form must be completed for each system This worksheet applies to Trench in Drainage Area (from plans) (from Form SWU-101) II DESIGN INFORMATION (attach supporting calculations/documentation) Soils Report Summary (based upon an actual field investigation and soil borings) Soil Type Newhan Infiltration Rate 20+ cf/hr/sf (circle appropriate units) SHWT Elevation 11.0 fmsl (Seasonal High Water Table elevation) Trench Design Parameters Design Volume 8485 c f Design Storm 4 inch event (1 S inch event for SA waters, I inch event for others) Drawdown Time 2 days STO P,465- I�GLCJ/-1 E Perforated Pipe Size 8 inch diameter Perforated Pipe Length 241 It No Observation Wells 0 Stone Type (if used) ll 57 washed Stone Void Ratio 40% Trench Elevations (infect mean sea level) (may be required on a case -by -case basis) Bottom Elevation 13 0 fmsl Storage/Overflow Elevation 9.77 fmsl (see narrative) Form SWU-107 Rev 3 99 Page 1 of 4 AUG 0 2 2006 BY ___ J Trench Dimensions Height Width 2 ft Length 4 ft Volume Provided III REQUIRED ITEMS CHECKLIST 241 It 8485 cu ft (see narrative) The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N C Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section If A NCAC 2H 1008 Initial in the space provided to indicate that the following design requirements have been met and supporting documentation is attached If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below Attach justification if a requirement has not been met Applicants Initials a System is located 50 feet from class SA waters and 30 feet from other surface waters b System is located at least 100 feet from water supply wells c Bottom of system is at least 2 feet above the seasonal high water table d Bottom of the system is 3 feet above any bedrock or impervious soil horizon (see narrative) e Off-line system, runoff in excess of the desi)gn volume bypasses the system (bypass detail provided) (3" d�¢515n S{CX h. us0 f System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration through the bottom only (a hydrogeologrc evaluation may be required) g Soils have a minimum hydraulic conductivity of 0 52 inches per hour h System is not sited on or in fill material or DWQ approval has been obtained i Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized Ir 3 System is sized to take into account the runoff at the ultimate built -out potential from all surfaces draining to the system, including any off -site drainage Lk System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way (see narrative) System captures and infiltrates the runoff from the first 1 0 inch of rainfall (1 5 inch event for areas draining to SA waters ) ( -j t dB 5j�)n 5{orrn Usea �^ in Drainage area for the device is less than 5 acres (see narrative) n A pretreatment device ( filter strip, grassed Swale, sediment trap, etc ) is provided L o Trench bottom is covered with a layer of clean sand to an average depth of 4 inches p Sides of the infiltration trench are lined with geotextile fabric q Rock used is free of fines (washed stone) and has a large void ratio r Side to bottom area ratio is less than 4 1 Form SWU-107 Rev 3 99 Page 2 of 4 AUG tl 2 2006 BY NA s Observation well(s) are provided (case -by -case bans) (see narrative) t Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans (51 Cie -Sign sbr w% USQci.) u A benchmark for checking sediment accumulation is provided IV UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT 1 After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition 2 Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance 3 Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth Restore depth to original design depth without over -excavating Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed 4 The water level in any monitoring wells will be recorded after a 1 inch rainfall event and at least once a month Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately 5 If DWQ determines that the system is fading, the system will immediately be repaired or replaced to original design specifications If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H 1000 must be designed, approved and constructed 6 Remove accumulated sediment from the infiltration system annually or when depth in the unit is reduced to 75% of the original design depth The system shall be restored to the original design depth without over - excavating Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i e stockpiling near a stormwater treatment device or stream, etc ) A benchmark shall be established in the infiltration system The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken The measuring device used to determine the depth at the benchmark shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments When the depth at the benchmark reads 4.5" , the accumulated sediment shall be removed from the system. (see narrative) RECETNT71D AUG (i 2 2006 Form SWU-107 Rev 3 99 Page 3 of 4 BY I acknowledge and agree by my signature below that I am responsible for maintaining the stonnwater collection system in accordance with the six maintenance procedures listed above 1 agree to notify DWQ of any problems with the system or pnor to any changes to the system or responsible party Print Name and Title &IRtA �). D Address Phone 910-612-8605 Signature Date 8/1/06 Note The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president t,,'^1,t 1 m e "A � 6 Yd" a Notary Public for the ,,State 1of II County of IV-I,U N"t1flGVt — , do hereby certify that �,h �t3pt� personally appeared before me this ,� day of , ZO%to , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements Witness my hand and official seal, U , �pTAq� SEAL i U My commission expires O RLC�T� rr,� Fomi SWU-107 Rev 3 99 Page 4 of 4 5 2 2006 I� AUG7BY----._- -J ccA» INFORMATION PERTAINING TO DEED RESTRICTIONS AND PROTECTIVE COVENANTS In accordance with Title 15 NCAC 2H 1000, the Coastal Stormwater Management Regulations, deed restrictions and protective covenants are required for High Density Residential Subdivisions where lots will be subdivided and sold Deed restrictions and protective covenants are necessary to ensure that the development maintains a "built -upon" area consistent with the design criteria used to size the stormwater control facility The following deed restrictions and covenants must be recorded prior to the sale of any lot 1 The following covenants are intended to ensure ongoing compliance with State Stormwater Management Permit Number as issued by the Division of Water Quality under NCAC 2H 1000 2 The State of North Carolina is made a beneficiary of these covenants to the extent necessary to maintain compliance with the Stormwater management permit 3 These covenants are to run with the land and be binding on all persons and parties claiming under them 4 The covenants pertaining to stormwater may not be altered or rescinded without the express written consent of the State of North Carolina, Division of Water Quality 5 Alteration of the drainage as shown on the approved plan may not take place without the concurrence of the Division of Water Quality 6 The maximum allowable built -upon area per lot is as follows Lot #'s 1, 3, 5, 7, 9, 12, 14, 15, 17, 19 BUA = 911 sf Lot #'s 2, 4, 6, 10, 11, 13, 16, 18 BUA = 875 sf Lot # 8 BUA = 694 sf SEE ATTACHED DIMENSIONED MAP These allotted amounts Include any built -upon area constructed within the lot property boundaries, and that portion of the right-of-way between the front lot line and the edge of the pavement Built upon area Includes, but is not limited to, structures, asphalt, concrete, gravel, brick, stone, slate, coquina and parking areas, but does not include raised, open wood decking, or the water surface of swimming pools 7 All runoff from the built -upon areas on the lot must dram into the permitted system This may be accomplished through a variety of means including roof drain gutters which drain to the street, grading the lot to drain toward the street, or grading perimeter swa/es to collect the lot runoff and directing them into a component of the stormwater system Lots that will naturally drain into the system are not required to provide these additional measures ByTitles �% wlva�fli4 bit Signature _ Date I, OD11-nP 4, `T_ n a notary public for the State of North Carolina, County of New Hanover, do hereby certify that Y1 1�c�. personally appeared before me this 2l`5i day of t , 2(ZL0 and acknowledge the due execution of this document Witness my hand and official seal, SEAL : *e �o•A9� *: My commission expires June .>;A?J8 T LG;'2�� 7SEP 2 ti''• • • o .� 1 2006 i4�gNVE � i uP 00 ```` ^ - — V •�i1� STROUD ENGINEERING, P A 102-D Cinema Drive WILMINGTON, NC 28403 // ;;�� (910) 815-0775 �vL TO E-Im WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via ❑ Shop drawings ❑ Prints ❑ Plans ❑ Copy of letter ❑ Change order ❑ D.1244NE @IF 4G3LQGrl��rt]�44LQ� DATE V ATTENTION wt. � RE I/ P ei( the following items ❑ Samples ❑ Specifications COPIES DATE NO DESCRIPTION 12 THESE ARE TRANSMITTED as checked below ❑ For approval ❑ For your use ❑ As requested ❑ For review and comment ❑ FORBIDS DUE _. REMARKS COPY TO ❑ Approved as submitted ❑ Approved as noted ❑ Returned for corrections ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return corrected prints ❑ PRINTS RETURNED AFTER LOAN TO US 4 SIGNED T If enclosures are not as noted kindly notify us at once 1 °T 1 Le I 1 6 1 -- i i I - T 1 1 , 1 , ' ' J L — — [Home use only] sw dgn 9/21/2006 11 31 18 AM STROUD ENGINEERING, P A 102-D Cinema Drive WILMINGTON, NC 28403 (910) 815.0775 TO ^,(-il6A/P\ WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via ❑ Shop drawings ❑ Prints ❑ Plans ❑ Copy of letter ❑ Change order ❑ �L�44C�G3 OCR 4G3L^al�l�[��44La� ^ GATEJIg JOB N t,✓` C'3 ATTEN N RE VI` C'�15�o^S �,,g D6fl�os the following items ❑ Samples ❑ Specifications COPIES DATE NO DESCRIPTION uM L<)Cf w jPa/ 2- THESE ARE TRANSMITTED as checked below ❑ For approval ❑ For your use ❑ As requested ❑ For review and comment ❑ FORBIDS DUE ❑ Approved as submitted ❑ Approved as noted ❑ Returned for corrections ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return corrected prints ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS I, m EN 5ieo C) oe x-1 I &)L L- c cry COPY TO SIGNED If enclosures are not as noted kindly notify us at once STROUD ENGINEERING, PA. CONSULTING ENGINEERS 102 D CINEMA DRIVE WILMINGTON, NORTH CAROLINA 28403 (910) 815-0775 September 8, 2006 NCDENR Attn Mary Jane Naugle 127 Cardinal Drive Wilmington, North Carolina 28405 Re Sea View SW8 060806 New Hanover County Dear Mary Jane, Please find the attached revised stormwater plan for Sea View per your comments 1 have addressed all of your concerns as follows The ground elevation in the immediate vicinity of the infiltration basin will be 15 5' to provide 0 5' of cover over the trench The buildings are located on individual lots whose Imes are within 5' of the building Areas on the property outside of the individual lots are common area and are utilized as private drainage easement All drainage infrastructure is located within said easement The lot lines and drainage infrastructure have been added to the Dimension Detail on page 2 of the plans for clarity 3 Existing catch basins located along Kure Village Way will be left in place in the gutter to catch runoff from the road New paved parking surface beyond this existing gutter flow line will be graded towards new catch basins 4 A 4" layer of clean sand is included in the trench cross section detail 5 Sealed calculations are included 6 Further investigation by the sod consultant indicates that our proposed site improvements will allow for adequate separation, as verified by Vincent Lewis The report is attached 7 The requested pump specifications have been added to the Junction Box/Sump Detail on page 2 Thank you for you assistance in this matter If you have any further questions or concerns, please do not hesitate to call Respectfully Yours, RECMNTRD SEP 0 S 2006 Luke Memus BY F t t' / RC653/w d/MJ2 t� d P P 102 D CINEMA DRIVE HESTRON PLAZA TWO 151 A HWY 24 GREENVILLE NC 27858 WILMINGTON NC 28403 MOREHEAD CITY NC 28557 (252) 756 9352 (910) 815 0775 (252) 247 7479 ''RF, S�-"�, September 1, 2006 Residential Foundation Testing Services PLLC Taylor Custom Homes r _ fF„ `c/o Stroud Engtneenng, PA- 5• �'V ,lY4I 102D Cinema Drive Wilmington, North Carolina 28403, ; - Attention 'Mr'LukelvMemus`} ? _ Reference . " Soils Infiltration Evaluation ` Sea Vi6w Project't South Foit Fisher Boulevard ; {; Kure Beach;,North Carolina RFTS,Job No 072-06' Dear Mr Memus • z ,As requested, RFTS has recently completed field46rk foi•the purpose of evaluating` soil irifiltration rates,withm an,area,proposed for use as a storm'water infiltration stricture on the above-r"eferenced project' Thts=letter summanzes.our field activities and'provtdes ; conclusions and recommendations relating to SinfiltrahonI rates PROJECT INFORMATION ,As we understand from our conversations °with,you, the" -area of the proposed infiltration structure will be prepared by removing organic soils,occumng in'the upper two feet•of„ 'grade and replacing -them with clean "sands -The infiltration structure will'then introduce. water into the on -site soils at a,depth of 6 to 12 inches below;the restored grade i,Asrthe _ site grade Will be raised approximately 2 feet dunng site grading operations, taus depth of--' ^ introduction will_correspond to a depth of 3'/s to 4'feet below final site grade ' 4' ' ' a ', ,f r ,> '♦_ "DESCRIPTION OF FIELD ACTIVITIES In'order to obtain data relevant to the evaluation of the infiltration' charactensties' of the in-place:soils, our representative visited the site ,on two occasions and perfoimed the ` ,r . following field work , t • I ' (July 12; 2006) Conducted infiltration testing using a Guelph Permeameter at a -test depth of 6 inches�`below,the'restored grade withm,an aiea`prepared'm % -, "accordance,with the procedures,`outimed'm Projectslnformation above (this ,corresponding to,a depth of,approximately'3% feet below the proposed firial'site ; grade) The permeameter is a constant -head device operating onz the '^ 1305 3A Carolina Beach Ave N _ Office 910-458-1377 .y Carolina Beach, North Carolina 28428 Fax 910-458-5261 i ' - ' CE 17 . . ` .5 «1, ' ♦ Y Y ar '*i Y f t, 1 'a' ✓ _ ;� t�ia �' r 1`h.' 1't . $ ,,., .'•, a ;3.. � y�r � �,. ' _ 7 ° x ti ^. `1' r ✓1 . � 'vi', .. Y114 to H ♦vV `�. nll �� .Ur: 1iT K ! rh = ~ • '•,y, �1 - Ir l �a • _(vta v a n ' ^4 ; J ' f '( � t .a ,•y n • .`I„{c \vt a ♦!+.} ` ` f 1 . l s C v"YI r .n , i r \ r -♦ � ♦ r t , � ♦ ?)c a rl „ \�'�• ' � � °+ �n � ' ar a l Y v -�Yfr „ J♦✓ � ,i fie � ' ' ��, •r- a .Fa � � -. p - hk air ., •a r ♦ ., ✓: .� ti[r, 'F� " - � r ^ ter' '�v , ' J r Vb v I L� r`vv yt f •F 'l !' 1 J a Rn r )lv _ Y t, t {«. _ _ 'tl i` r) rV vd .��.., u , `r rKf•� i a c `I) .r". r a f ,iv + �m:.� ."'�^+ ice, )', " � tom. >.� ♦fix ' +v+ t, � n,lr,. h. � i I 1 ..` r 9 ` `'1 r r 1 t 'Y' S ♦ , �� t Y , � rF �_ J ' s ' � � , rl � ^l v 3, �, � � .� r . _ r �� nt � ��+ � � r'� �� rt,� v" ��! J`�4.a �1A �,� �.3 � rrk �•�� -ir i� Ir � r_ ,,tr .v I, , , V ,� 'Le Nt _.)1 a ♦i - � ' v ~ 1 ` yM ' r « l x, v _ 1 , • ,l'r , 1� 1 r _s'f r',' a . , r , A . ♦ r, l .S ., \ 4V,,*f i . f� •'��r'\�2'_ al a, }' 1 ' a ,\��� , rl ` �s t rt ♦ .. - r a r ' ♦ a i , - ys ,, . '�♦ 1 T. i%^ ' rjy;r-r ,,� tfr.^ ^,1_ ' Taylor Custom Homes September 1; 2006 RFTS Job No ,672-06 Page Two, . . Manotte'siphon principle ' It'is described m'ASTM D5126 The permeameter is 'used to determine field,saturated hydraulic conductivity in centimeters per second - for soil at a specified depth This testing involves advancing,a borehole to the' : Y P desired mfiltration'depth and mtroducmg water at a constant head to determine'a'' ` steady-state flow rate from)which hydraulic conductivity can be calculated 2 (August 14,12006) Advanced a hand auger-bonng to a'depth of 64 inches - a"`' below site grade at an undisturbed location (i e; a location which had uot'been y ' :E prepared m.accordance,with the procedures outlined in Projeah4onnation above) _ y for.the piupose of identifying the soil profile occumng pnor,to construction of the " infiltration structure ; The soils, encountered in the boring were ` logged and visually classified by depth, and their coloration was compared to'a Munsell Soil Color Chart to estimate their rkelative degree of aeiation r } 'FINDINGS AND'R_ECOMMENDATIONS ' ' "Our field -data is -shown -in detail m=the' attached tables -Based on our permeameter, testing; the soils' -within- anarea prepared- as -proposed above exhibit a, stabilized infiltration rate inexcess of 300 inches per hour 'The soil stratigraphy shown'in our hand auger'bonng indicates that ohcejhe oigamc soils occurring m,the upper 2;feet have been -' removed, the underlying soil`s' exhibit coloration indicative of;adequate drainage to`a' + depth of 46'inches' ,We recommend•that the, site of the infiltration.structuie,be prepared 1 as you have 'proposed and that the system be sized on the.basts of an infiltration"rate not exceeding the rate'given above li , CLOSURE ` RFTS appreciates the opportumiyIto b`e�of service to you on this` project tf you should have questions or,if we may be of addinonal assistance, please do`not hesitate to cohtact r ,us Sincerely, �RFTS;M1j'LLC �.!M.G.✓- �� , ° David L Winstead Steven' E Field Operations Manager ; _ Senior Engineer, e.••`°��-CAR ~��• DLW SDK/dlw • o�°°_'��F�J����.✓ 9 �. Attachments o I2ECE�VED /SEAL , 11fi38. , f 3 _SEP 0 �'2006 FL `�tiS! E�`�f •�f z _ N.«.� BY a OALTTk" r —= emu««u„�"`. _ �v I r a -�.. 3 Y r - - � , / n y. � v - ^ r h 1 t t r rl. t Y i } ' ~ � � � _ � � r r rY \ n � � . n ) •1. �, r . rFl • J n ; 1 . _ t r `, ' n . r`W , • ~' y'trr�` r _. t rl , r `f` • ti ,. s� 1 r r ' `- nyY n"1� ;'y-�J' '1 fr r rYn Y ' ,' 4 � r• 1 r 1 1 n - 1 i l • n `±I ly + s r ' A r R 6 / ( �t �. - ti � � i J r � h 1 t . r ..f - ) f e 1 . yt r ; _ r ^ � - y e. �- r .. n� � 1 n ..r _ y • 4 a r y� � t i } _ {.t Y Y 1 f � t r 1 n y 1 r t 4 t' ` y r �! S t •• .` � 4° u� 1 ` t " F f I ' •� Y Y rY - a. , _Y y - r �4 � / i � / Jn • ' �, � a L4�+ � t f t _' n �/ �'�I���r r • - �iry � � Y 'ff'� rn r ry ���n�'1 � � -+^pry � r - It. t'r-. � �� n -r� � t� •f 'h ' � . nix- .In y /\A' t'i \� If y. ri 4 � xl r-�'K� •i ... e" 1' _Y kr'£ t� ." a Y 1_ •�I n � .. 1 J v� 1 r s et � t! � +r �. T f'A�, f ti r l r Y ..c^ r ` ±� 4 ,. ,' .. _ � - t r, - ern �r �r r1 <• rft° �r � N✓ �'r r t. `f� f.-. tr��r -+n {`.' n I rr Ar}`J �. .r , `''Vv�'. J r ,Y Y ,)� `-nl v` h^r I ♦In �alyr4 )'y�\� _ - ♦� ♦ -T`i'Y' � rr it 1 r V y♦ 'Yt 1rr!` r , t r, fr.J nIr} r r , '' ♦ r•+ , V_ r+' `• nt n - •Y)•� ♦ Y r r � t , r V . t r ._� • 1 r .'�ljr y � .`' ' .l ♦ . t t _ I •n t ' f.j� �/ ' - a r y Y l t i n fly y 1 r ' n ' .�. aty` / rt � .$ yy4r �\ 'Y � .t t rY. a' Y• _> a � i •.,, .� 1 �r r r � f r 1 _ r � t ,' � � r Y e . ,�� �:1 � �'t r ' 'la ° Y1 • ' , ' Y f r _ rr .. 1 r ' ^` '°' ''rt rt� � r YJ' � ) / } xY.. •^rc • le. nr 'f M1 r.'1 - f n`l - r 1 °,� ,},'fr n !' •f '! `il i . P 4 r _ � • r ' f . t -,. f y` , ` ., = `u }. ;~ 'ft t/ y _ i /{rt ar f r ♦ t� «..� � 1 .- rit rl ` � . 1 ^Y. ! ''♦ r •rIRY \HMV; . �+ r. ,y.r r ; l� ' r n .Y V \ � n Irµ ,� "r 1 / 1 � If r' h t fy � .>> �x f n r ,t �.1 i. r . � r .f . ' 1 r . i r4. 1 � fin 'nl n ° 1 �1 r e ] r Y. . yt / .r �. 1 r Yr � y-" s _••� "rtt ti i � - '�.� °-� � r n� r i 1 >, s � ,�` �.. r ,r ` r �+ ' y'. rr' .'t r. n ' 1 r = � - r.5 * }r f f• '\r ' ,. ,t.. _ d, 4 f•Y � • �4 �����'r �/ - � rr� y � 1 y � 'J � , 0, � � yr t y r r u r y A 44 r � t � r �' y � e y r y � . r D' ° y 1 1 d 'F I • f .. Y' 't '. r, •' n � r 1 - f� r n 1 n � •• � z F r r I r ` - r 1. ' � 1 - � t t .� � r Page 1 of 2 PUMPS TH �p PROS USE � � PLliLJP !O- BackF,.. Known Capacity Dewatering r________-______ _,__ ____ vM r • s 6 U ®w% Flow System Curve GPM TT) 000 1300 21 00 1351 4200 1486 6300 1693 8400 1970 10500 2313 12600 27 19 Entered GPM 2200 TDH at Entered GPM (ft) 1366 Suggested Pumps ■ Curve \ Equilibrium GPM 30 22 TDH 1401 Pumps 264 , Sizing ID 36595 Job Number PW-653 Modified 8/1/2006 4 24 00 PM Job SEA VIEW Address Customer Phone Contact Contractor Address Phone ■ Curve Equilibrium GPM 4714 ��"au,enr„•• TDH 1530 �.``' ZoOL.IN, •4,� Pumps : Q�'k(a5$1ON��♦ 266 ;6 267 L �h �4% ENO% •ice S H F ��` T�k�\ 9�q:avx� C- RECP-:TlrP--D SEP 08 2006 BY http //www zoeller com/pumpproselect/webpp_isaT_ll/EXEC/36_/ 8279107F96D26525502 8/l/2006 diµ �Y�iq r�,e J n � t 1+ .'per �r� �. 5 s,',� y3, his ;ci aid ,.'' ,VJ� � ��y1�y�� F4,�a`�'� ,�'thn��epdn• Page 2 of 2 Electrical 220 volt, 1 phase, 60 Hertz Physical Dischage Size (IPS) 200 Pipe Size (IPS) 200 Pipe Length (ft) 250 Type of Pipe Plastic Solids Handling (in) 038 Static Head (ft) 1300 Discharge Press 0 00 psi Fittings Thru Tees Branch Tees 450 Elbows - 90° Elbows 4 Gate Valves 1 Check Valves 1 7SEP 0 8 2006 http //www zoeller com/pwnpproselect/webpp_rsapi dll/EXEC/36/98279107F96D26525502 8/1/2006 rip11//L777 SECTION 230015 QUdL/TY PUMPS SNCE �PiJp /, O ` FM5 030 305 Product intonation presented �\ Z� Supersedes here reflects conditions at time — /PUMP CO ® 0404 of pubticaUon Consult fac tory regarding discrepancies or Inconsistencies MAIL TO PO BOX 16347 Louisville KY 40256 0347 visit our web site SHIP TO 3649 Cane Run Road • Louisville KY 40211 1961 www zoeller com (502) 778 2731 1(800) 928 PUMP • FAX (502) 774 3624 COMPARE THESE FEATURES • Non -Clogging Vortex Impeller Design 264 SERIES • Float operated, submersible (NEMA 6) 2-pole switch • Durable cast iron construction Cast Iron switch cap, motor, and pump housing • Engineered plastic base • Stainless steel screws, bolts, handle, guard, arm and seal assembly • Engineered, glass -filled, plastic Impeller with metal insert • UL Listed 3 wire cord and plug 15 ft cord standard for auto- matic & nonautomatic Corrosion resistant powder coated epoxy finish • Motor - 4 HP 115V & 230V,1 Ph , 60 Hz,1725 RPM, oil filled PSC motor, hermetically sealed, automatic reset thermal overload protection • Upper and lower sleeve bearings running in bath of oil Carbon and ceramic shaft seal • Passes 2 inch spherical solids • 2" NPT Discharge On point 12'/2' Off point - 4Yz" Note The sizing of effluent systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles or dosing timers with nonauto- matic pumps SIMPLEX AND DUPLEX SYSTEMS AVAILABLE Z� PUMP !O "WASTE -MATE" (For Pump Prefix Identification see News & Views 0052) SUBMERSIBLE SEWAGEIEFFLUENT* U� OR DEWATERING PUMP rm"emuranw,emm 2" NPT DISCHARGE 6LM,el IO LSA SbtivOCMW 10 SSPMA POWDER �MSEMW�AGE .COATED TOUGH" PUMP MiR$ RSSN MODELS AVAILABLE Automatic Nonautomatic (for variable level systems) BE & BN264 available packaged with Manufacturers of Piggyback variable level Moat switch �. Pip � T�TT TTTT QVOL/TY PUMPS SNCE ��J�/ May be used m those states where codes do not restrict solids sl a In effluent systems -- © Copyright 2005 Zoeller Co All rights reserved S E P 0 3 2006 co LL PUMP PERFORMANCE CURVE MODEL 264 15 10 GALLONS LITERS 320 FLOW PER MINUTE TOTAL DYNAMIC HEADIFLOW SEWAGE AND DEWATERING MODEL 264 Feet Meters Gallonsff22 5 15 90 10 30 6015 46 23 Shut-off Head 18 R (5 5 m) 1 0UA31 100 1a 3u 413116 r 821I64 B1Na - CONSULT FACTORY FOR SPECIAL APPLICATIONS Electrical alternators for duplex systems available with variable level float switches Minimum recommended basin size Simplex-18"x30" Duplex-30"x36" Standard Automatic - Weight 34 51bs 4 H P High water alarms available Mechanical alternators available for duplex systems A CAUTION Maximum temperature of sewage or dewatering must be limited to 130°F (54°C) For over 130°F (54°C) special quotation required 413116 1 s3W SN1643 For "M" and "D" models, the approximate gallons pumped out per cycle are Tank Diameter Gallons Pumped 18" Simplex 8 Gallons 24" Simplex 15 Gallons 30" Duplex 22 Gallons 36" Duplex 33 Gallons 48" Duplex 60 Gallons 264 MODELS CONTROL SELECTION Model Volts Ph Mode Amps Simplex Duplex M264 115 1 Auto 94 1 4 N264 115 1 Non 94 2 or 3 4 D264 230 1 Auto 47 1 4 E264 230 1 Non 47 2 or 3 4 SELECTION GUIDE 1 Integral float operated mechanical switch, no external control required 2 For automatic use single piggyback variable level float switch or double piggyback variable level float switch Refer to FM0477 3 See FM1228 for correct model of simplex control panel 4 See FM0712 for correct model of duplex control panel or FM1663 for a residential alternator system A CAUTION For mforeni on additional Zoeller prcdude refer to clelog on Piggyback vanade Level Float Smi FI00477 Alllnstallabon of controls protection devices and wiring should be done by aqualdied licensed Electrical Ntemater F140466 Medanlal AWmeWr FMi Sump/Sewage Barns FIAW7 and Single Phase electrician All electrical and safety codes should be followed Including the mostrecent National Sunplea Pump CunW FM1596 Aa. SysNm FWM2 Electric Cade (NEC) and the Occupational Safety and Health Act (OSHA) RESERVE POWERED DESIGN For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump MAILTO PO BOX16347 �y , � ® SHIP TO le 49 one Ru Road ManWacfvrers of SHIPTO 3649 Cane Run Road pp ® LomsWlle KY 40211 1961 QUd(/TY PUMPS SNLE �Pjp v www zoeller com PUMP !O. (502)776X(5 1(PUMP FAX (02) 7743 624 r` © T_ Copyright 2005 Zoeller Co All rights reserved - SEP 0 8 2006 Michael F Easley, Governor \O�OF W ATF9oG August 11, 2006 Mr Brian Dodd, Manager Member Sea View Investment Group, LLC P O Box 745 Kure Beach, NC 28449 Subject Request for Additional Information Stormwater Protect No SW8 060806 Sea View at Kure Beach New Hanover County Dear Mr Dodd, William G Ross Jr Secretary North Carolina Department of Lnvironment and Natural Resources Alan W Klimek P E Director Division of Water Quality The Wilmington Regional Office received a Stormwater Management Permit Application for Sea View at Kure Beach on August 2, 2006, with supplement drawing revisions on August 4, 2006 The project is scheduled for an Express permit review on August 7, 2006 A preliminary review of that information has determined that the application is not complete The following information is needed to continue the storm water review t/1 If the bottom of the trench is at elevation 13, and it's 2' high, the top of the stone in the trench will be at elevation 15 The proposed ground elevations in the area of the trench are between 14 5 on the west side and 15 on the east side The proposed ground elevations indicated do not allow for any cover depth over the trench era ftk+Jf tic�,S ca2ounkP 2 Please show and label the proposed drainage easements for access to the nearest public right-of-way [re Infiltration supplement, item no III (k)) 3 The application indicates that there is no offsite drainage, however, it appears that runoff k from the existing Kure Village Way may be entering the system This runoff must be accounted for in the trench system unless it can be separated from and bypassed around G this project ,/4 Please show the four (4) inch layer of clean sand in the bottom of the infiltration trench on the plan detail This is in accordance with item no III (o) on the Infiltration supplement MmP (-"JF 5 Please seal the trench and pump design calculations rzco tom, 6 The soils report must•contain an estimate of the seasonal high water table elevation The Soils Scientist is sent to the site to verify the information reported in the soils report for the kefo l benefit of the Division You may not use the information that he obtained in that site visit to take the place of a full soils investigation Please have your soils consultant make a determination of the SHWT and revise the soils report to contain this information 7 Please provide specific information on the plans regarding the chosen pump to include the model number and letter, gpm, TDH, voltage, etc Please note that this request for additional information is in response to a preliminary review The requested information should be received by this Office prior to August 25, 2006, or the application will be returned as incomplete The return of a project will necessitate resubmittal of all required items, including the application fee N�°o�cn Carolina " A(ra!!y North Carolina Di, ision of Water Quality 127 Cardinal Dnve Extension Wilmington, NC 28405 Phone (910) 796 7215 Customer Service Wilmington Regional Office Internet www ncwaterauahty ore Fax (910) 350-2004 1-877-623-6748 An Equal Opportunity/AKrmalive Action Employer— 50% Recycled/10% Post Consumer Paper Mr Dodd August 11, 2006 Stormwater Application No SW8 060806 If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter, to the attention of Mr Cameron Weaver — Express Permitting The request must indicate the date by which you expect to submit the required information The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215 1 and is subject to enforcement action pursuant to NCGS 143-215 6A Please reference the State assigned protect number on all correspondence Any original documents that need to be revised have been sent to the engineer or agent All original documents must be returned or new originals must be provided Copies are not acceptable if you have any questions concerning this matter please feel free to call me at (910) 796-7303 Sincerely, Mary Jean Naugle NC DWQ Express Permitting WiRO ENB/m1n S\WQS\STORMWATER\ADDINFO\2006\060806 aug06 CC Luke Menws, Stroud Engineering, 910-815-0775 [fax 0593) M J Naugle SM 060806 Sea View Express Review Comments f Subject: SW8 060806 Sea View Express Review Comments From. Linda Lewis <Imda lewis@ncmail net> Date: Fn, 11 Aug 2006 13 04 55 -0400 To: Luke Menius <Imenms@stroudengmeer com> CC: Mary Naugle <Mary Naugle@ncmail net> Luke On behalf of Mary Jean Naugle, attached please find her Express Review comments for this project Linda )60806.aug06 Content -Type: applicatlon/msword doc Content -Encoding: base64 I of 1 8/28/2006 7 56 AM STROUD ENGINEERING, P.A. 102-D Cinema Drive WILMINGTON, NC 28403 (910) 815-0775 TO /t L &'j1 WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via ❑ Shop drawings ❑ Prints ❑ Plans ❑ Copy of letter ❑ Change order ❑ dIEVVIEn O[� 4QH@W0VVRJL DATE b I 6 JOB NO _- I '!mow/ ATTENTION g q,n GM M T RE CC JC4 ��e W the following items ❑ Samples ❑ Specifications COPIES DATE NO DESCRIPTION Z /� I - ,, / le V i i frbw� � +-z L o Q AF TS e A- A9 JQA--� �@ ecQ 0(9 THESE ARE TRANSMITTED as checked below ❑ For approval ❑ For your use ❑ As requested ❑ For review and comment ❑ FORBIDS DUE ❑ Approved as submitted ❑ Approved as noted ❑ Returned for corrections ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return corrected prints ❑ PRINTS RETURNED AFTER LOAN TO US Ple�k. �.�d *-fie ei-a, coed 1%)to-..s 4 V..✓- COPY TO SIG /f enclosures are not as noted, kindly notify us at once CLIENT NCDENR EROSION CONTROL AND STORMWATER PLAN SEA VIEW AUGUST 2, 2006 SEA VIEW INVESTMENT GROUP, LLC PO BOX 745 KURE BEACH, NC 28449 STROUD ENGINEERING, P.A. 102 D CINEMA DRIVE WILMINGTON, N.C. 28403 (910)815-0775 File f \master\pw-653\wpd\ecpcov wpd 1�CFl`s� 775 AUG 0 4 2006 BY ��� , ...., rrr -. O•,Si '-� jh.ar p. ?� � �' p r, ...�iunui`. Erosion Control and Stormwater Protect Narrative Sea View PW-653 8/2/06 Proiect Summa The purpose of this project is to construct residential homes on 1 53 acres of land located Kure Beach, NC at the corner of US 421 and Kure Village Way Nineteen homes are planned in this development Site Description The topography of the site is essentially flat Existing drainage on site is generally from west to east, towards Fort Fisher Blvd Adiomma ProDe Adjoining property is primarily residential The site is bordered to the East by Fort Fisher Blvd and to the north by Kure Village Way Sods Soils in the project area are mapped in the New Hanover County Soil Survey as Urban A site visit revealed a coarse, sandy spoil type material underlain by material consistent with Newhan Fine Sand This material is afforded rapid (>20 in/hr) infiltration The SMHW was located at a depth of 24" (elev 11 00) by Vincent Lewis Planned Erosion and Sedimentation Control Practices Silt fence will be used extensively around the perimeter of the project to control offsite sedimentation All stormwater inlets will be protected with silt fence as well A temporary gravel construction entrance will be located on the northwestern corner of the project, off Kure Village Way Planned Stormwater Management Practices The collection system on this site consist of 1215 LF of 36" RCP graded towards a centrally located junction box This box will contain an automatic pump which will dewater the 8485 CF of water impounded within the RCP collection system in 2-5 days The adjacent infiltration trench consists of 241 LF of 8 perforated polyethylene pipe situated in a 4' wide by 2' deep trench filled with washed #57 stone The bottom of the trench is at elevation 13 00' and has a SA of 964 SF The required volume for the system is wholly contained by the 1215 LF of 36" RCP and the infiltration rate will be set by the pump's gate valve The 20+ in/hr infiltration rate only requires 107 SF of trench bottom The additional trench has been provided in an effort to reduce the risk of system failure The system is designed to collect the 1" 3" of rainfall due the lack of both a vegetative filter and a bypass Outfall for water in excess of 3" is provided by a weir located in catch basin 1 This weir is set at elevation 9 77', which is the elevation of the top of the 36" RCP Upon overtopping this weir, water flows into the existing storm drain and into the Atlantic Ocean The invert of the 36" RCP at the sump is 6 00' The invert of the sump itself is 5 63' This 0 37' space is the required operating depth of the pump The pump will switch on at an elevation of 6 60' This 0 6' space above the pipe invert is provided to allow the pump time between cycles AUG 0 4 2006 BY SOSID 713675 Date Filed 2/26/2004 4 13 00 PM Elaine F Marshall North Carolina Secretary of State C200405700114 ARTICLES OF ORGANIZATION OF SEA VIEW INVESTMENT GROUP, LLC The undersigned hereby submit these Articles of Organization for the purpose of forming a limited liability company under the laws of the State of North Carolina ARTICLE 1 NAME The name ofthe limited liability company is "SEA VIEW INVESTMENT GROUP, LLC"(the "Company") ARTICLE II PERIOD OF DURATION The latest date on which the limited liability company is to dissolve is January 1, 2054 ARTICLE III PURPOSE The Company is organized for the purpose of constructing and developing real estate The Company shall have authority to take any actions allowed by law, which are necessary to effectuate the above purpose, both within or without the State of North Carolina The Company shall also have the authority to engage in any other activity allowed under the laws of North Carolina ARTICLE IV INDEMNIFICATION A To the fullest extent permitted by the North Carolina Limited Liability Company Act as it exists or may hereafter be amended, no person who is serving or who has served as a manager of the Company shall be personally liable to the Company or any of its members for monetary damages for breach of duty as a manager No amendment or repeal of this article, nor the adoption of any provision to these Articles of Organization inconsistent with this article, shall eliminate or reduce the protection granted herein with respect to any matter that occurred prior to such amendment, repeal or adoption rpz E9CFT�:� AUG 0 4 2006 BY B Each person who is serving or who has served as a manager of the Company shall have a right to be Indemnified by the Company against any payments made or personal liabilities reasonably incurred by such manager in the authorized conduct of the Company's business or for the preservation of the Company's business or property C The Company may, by action of its managers, provide indemnification to such ofthe officers, employees, and agents of the Company to such extent and to such effect as the managers shall determine to be appropriate and authorized by applicable law D The rights and authority conferred in this Article shall not be exclusive of any other right which any person or the Company may have or hereafter acquire tinder any statute, provis,on of the Articles of Organization or Operating Agreement of the Company, agreement, vote of members or disinterested managers or otherwise ARTICLE V MEMBERS AS MANAGERS ('All members, by virtue ofiheir status as members, shall be managers of the Company `i ARTICLE VI INITIAL REGISTERED AGENT AND REGISTERED OFFICE The street address and county of the initial registered office of the Company is 509 Princess Street, Wilmington, North Carolina 28449, County of New Hanover The name of the initial registered agent at the registered office is Lawrence S Craige ARTICLE VII ORGANIZERS The name and address of the organizer executing these Articles of Organization is NAME ADDRESS Lawrence S Craige 509 Princess Street Wilmington, NC 28401 2 RECEIVED AUG 0 4 2006 BY ARTICLE VIII EFFECTIVE DATE These Articles of Organization shall be effective upon filing with the office of the Secretary of State of the State of North Carolina This the 23rd day of February, 2004 (Seal) Laµrence S Craige, Orghnizer FF,CG'F-T r ,� AUG 0 4 2006 BY - LIMITED LIABILITY COMPANY ANNUAL REPORT(42) C200508900530 SOSID 0713675 Dale Filed 3/30/2005 2 58.00 PM Elaine F Marshall North Carolina Secretary of State C200508900530 NAME OF LIMITED LIABILITY COMPANY Sea View Investment Group, LLC STATE OF INCORPORATION NC SECRETARY OF STATE L L C ID NUMBER 0713675 NATURE OF BUSINESS Real Estate REGISTEREDAGENT Lawrence S. Craige REGISTERED OFFICE MAILING ADDRESS P 0 BOX 745 Kure Beach REGISTERED OFFICE STREET ADDRESS 701 Market Street Wilmington New Hanover SIGNATURE OF THE NEW REGISTERED AGENT \ !� FEDERAL EMPLOYER ID NUMBER 20-0962756 NC 28449 NC 28401 SIGNATURE CONSTITUTES CONSENT TO THE APPOINTMENT PRINCIPAL OFFICE TELEPHONE NUMBER 910-815-0085 PRINCIPAL OFFICE MAILING ADDRESS P 0 Box 745 Kure Beach NC 28449 PRINCIPAL OFFICE STREET ADDRESS 701 Market Street Wilmington NC 28449 MANAGERS/MEMBERS/ORGANIZERS Name Lawrence S Craige Tide Member/manager Name Brian -D- -Dodd , Tide Member/manager Name Title Address P 0 Box 745 city Kure Beach Address P.O. Box 745 city Kure Beach Address City Slate NC Zip 28449 state NC zip 28449 State Zip CERTIFICATION OF ANNUAL REPORT MUST BE COMPLETED BY ALL LIMITED LIABILITY COMPANIES J6J.4 C U C7 FORM MUST BE SIGNED BY A MANAGER/MEMBER DATE G4%w, ,,cc S Cru,tL /1fn�C`/^Ac btr TYPE OR PRINT NAME TYPE OR PRINT TITLE ANNUAL REPORT FEE $200 00 MAIL TO Seuetary of State 0 Corporations Division 0 Post Office Box 29525 0 Raleigh, NC 27626-0525 20096275W LIMITED LIABILITY COMPANY ANNUAL REPORT M00611900450 SOSID 0713675 Date Filed 4/29/2006 1 28 00 PM Elaine F Marshall North Carolina Secretary of State C200611900450 NAME OF LIMITED LIABILITY COMPANY Sea View Investment Group, LLC STATE OF INCORPORATION NC SECRETARY OF STATE R L L P ID NUMBER 0713675 NATURE OF BUSINESS Real Estate FEDERAL EMPLOYER ID NUMBER 20-0962756 REGISTEREDAGENT Lawrence S. Craige REGISTERED OFFICE MAILING ADDRESS P.O. BOX 745 NC 28449 Kure Beach REGISTERED OFFICE STREET ADDRESS 701 Market Street NC 28901 Wilmington New Hanover SIGNATURE OF THE NEW REGISTERED AGENT SIGNATURE CONSTITUTES CONSENT TO THE APPOINTMENT PRINCIPAL OFFICE TELEPHONE NUMBER 910-815-0085 PRINCIPAL OFFICE MAILING ADDRESS PRINCIPAL OFFICE STREET ADDRESS MANAGERS/MEMBERS/ORGANIZERS P 0 Box 745 Kure Beach 701 Market Street Wilmington Name Lawrence S. Craige Title Member/manager Name FBrian -D Dodd, Tide Member/manager Name Tide NC 28449 NC 28449 Address P.0 Box 745 City Kure Beach Address P 0 Box 745 city Kure Beach Address City CERTIFICATION OF ANNUAL REPORT MUST BE COMPLETED BY ALL LIMITED LIABILITY COMPANIES state NC zip 28449 State NC zip 28449 co 0 0 N Stale zip !N Q FORM MUST BE SIGNED BY A MANA EMBER DATE LF,,.-rr,.E j C1, rimer, 4r1v`IC-^tlfr TYPE OR PRINT NAME TYPE FOR PRINT TITLE ANNUAL REPORT FEE $200 MAIL TO Secretary of State • CorporaWns Division 9 Post Office Box 29525 0 Raleigh, NC 27626-0525 R F7 Residential Foundation Testing Services, PLLC Taylor Custom Homes C/o Stroud Engineering, P A 102 D Cinema Drive Wilmington, North Carolina 28403 Attention Mr Luke Menius July 18, 2006 Reference Infiltration Testing Sea View Project South Fort Fisher Boulevard Kure Beach, North Carolina RFTS Job No 072-06 Dear Mr Memus NUG 0 4 2006 ;w$ O(oosoG RFTS is pleased to provide testing services during the construction of the residential structure off South Forth Fisher Boulevard located in Kure Beach, North Carolina The site currently has an unoccupied retail structure and site grade is relatively flat with gentle slopes Specific site grading plans had not been provided to us at the time this report was prepared DESCRIPTION OF ACTIVITIES AND FINDINGS As requested, our staff visited the site on July 12, 2006, to perform infiltration testing at one location identified on a drawing faxed to our office from you The purpose of this testing was to provide the civil designer soil parameters for stormwater infiltration design It is our understanding that a representative of the state previously determined the depth to the seasonal high watertable, therefore we did not make an estimate during our testing It was noted that the area in which our testing was performed had previously been disturbed Based on our observations, the area had been undercut approximately three feet below the existing ground surface and backfilled with a clean sand The spoils from the excavation work had been stockpiled near the test area and appeared to contain a significant amount of organic matter As we understand, it is proposed that the area of on -site soil infiltration structures will be prepared by an identical undercutting and backfill operation and that site grade will then be raised by filling an additional two feet Infiltration structures will then introduce runoff water into the ground at a depth of two feet below the raised site grade 1305 3A Carolina Beach Ave N Office 910-458-1377 Carolina Beach, North Carolina 215428 Fax 910-458-5261 ,, Taylor Custom Homes RFTS Job No 072-06 Infiltration Testing July 18, 2006 Page Two Infiltration testing was performed using a model 2800 Guelph Penneameter which is a constant -head device operating on the Manotte siphon principle It is descnbed inASTM D-5126 The penneameter is used to determine field saturated hydraulic conductivity in centimeters per second for soil at a specified depth This testing involves advancing a borehole to the desired infiltration depth and introducing water at a constant head to determine a steady state flow rate from which the hydraulic conductivity can be calculated It was requested that this testing be performed at or near the ground surface in the prepared area so as to match the elevation at which runoff water will be introduced into the ground from infiltration structures Testing was performed at 6 inches below the ground surface The results of our permeameter testing are presented in Table 1 FINDINGS Based on the results of our field testing and soil classifications at the test locations, it is our opinion that in order to achieve the steady state flow rates obtained during our testing, areas of infiltration galleries or other infiltration structures should be undercut and backfilled as in the prepared test location area For purposes of sizing the structures we recommend an ultimate application rate of 300 inches per hour for water introduced at a depth of two feet below grade These recommendations should be reviewed by appropriate regulatory authorities before finalizing the details of any civil design CLOSURE Please find attached our field data and a sketch showing the approximate test locations If you have any questions after reviewing this letter, please do not hesitate to contact us at your convenience Sincerely, RFTS,PLLC � Z David L Winstead Field Operations Manager Steven D KeTI, PE Senior Engmee DLW SDK/dlw _ Attachments '-' — "+�— �' _�' D 1'`.. any c ALI'1 n 7^OF BY DLt7Q- SEAL r 17638 �f NE•�� )ALTON ti.•r Table 1 Guelph Penneameter Test Results Sea View Project South Fort Fisher Boulevard Kure Beach, North Carolina RFTS Job No 072-06 Location 1 Depth (m) 6 H, (cm) 5 Ri (cm/mm) 497 Rls (cm/sec) 0 828 H2(cm) 10 Rz (cm/mm) 700 Res (cm/sec) 12 Kf, (cm/sec) 0 662 (Dm (cm/sec) 41 6 a (cm) 00159 Definition of Terms Rt,z — Rate of water level change (cm/mm) in meter established as constant over three or more readings RI s zs — Calculated steady state flow rates (cm/sec) HI 2 — Maintained Head of H2O (cm) K& — Calculated field saturated hydraulic conductivity (cm/sec) 0m — Matnc flux potential (cm/sec) a — Alpha parameter Depth — Depth of well hole (in) Location — Test location identification number Note Diameter of well is 3 0 cm RECEIVED AUG 0 4 2006 BY: STROUD ENGINEERING, P.A. 102-D Cinema Dnve WILMINGTON, NC 28403 (910) 815.0775 TO WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via ❑ Shop drawings ❑ Prints ❑ Plans ❑ Copy of letter ❑ Change order ❑ IIE LJ LJ Nn @0 LJ �UHQMVVII oATE4FJoe Z o6 NO W ATTENTI N _ Q A _ _ GY RE SW V Ci1�i ❑ Samples the following items ❑ Specifications COPIES DATE NO DESCRIPTION C� I OOO.O D Gt �j OS�S THESE ARE TRANSMITTED as checked below ❑ For approval ❑ For your use ❑ As requested ❑ For review and comment ❑ FORBIDS DUE ❑ Approved as submitted ❑ Approved as noted ❑ Returned for corrections ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return corrected prints ❑ PRINTS RETURNED AFTER LOAN TO US COPY TO SIGNED"-- /{ enclosures are not as noted, kindly notify us at once STROUD ENGINEERING, P.A CONSULTING ENGINEERS 102 D CINEMA DRIVE WILMINGTON, NORTH CAROLINA 28403 (910) 815 0775 August 2, 2006 NCDENR Attn Mary Jane Naugle 127 Cardinal Drive Wilmington, North Carolina 28405 Re Sea View New Hanover County Dear Mary Jane, Please find the attached submittal package regarding the stormwater plan for Sea View We are proposing a infiltration system to dispose of stormwater runoff from driveways, residences, and parking for 19 units A detailed narrative is attached to aid in your review, but please feel free to contact me with any questions or concerns Respectfully Yours, Luke Menius Attachments File F /master/Pw653/wpd/MJ wpd AUG 0 2 2006 BY -1 107 COMMERCE ST HESTRON PLAZA TWO SUITE B 102 D CINEMA DRIVE 151-A HWY 24 GREENVILLE NC 27858 WILMINGTON NC 28403 MOREHEAD CITY NC 28557 (252) 756-9352 (910) 815 0775 (252) 247 7479 TOTAL AREA (AC) = PROPOSED IMPERV AREA (AC)= % IMPER AREA = PROPOSED PERVIOUS AREA (AC)= % PERVIOUS = PROJECT SEAVIEW PROJECT# PW-653 DATE 06/22/06 1 53 66832 SF 078 34000 SF 0 509 075 0 491 STATE REQUIRED STORAGE FOR 1ST 3 0 IN OF RAINFALL RUNOFF = 0 05 + 0 009 X %IMPERV = RUNOFF = 0507864496 REQUIRED VOLUME = 3 0 IN X RUNOFF X AREA X 43560 SF/AC/12 IN/HR VOLUME (CF)= 8485 PIPE DIA CF PER LF REQUIRED LF 36 707 1200 PROVIDE 1215 LF DRAWDOWN TIME (2 5 DAY) TOTAL STORAGE = 2 DAY PUMP RATE 5 DAY PUMP RATE INFILTRATION RATE= REQUIRED 2 DAY AREA= 8485 CF 63475 GAL 220 GPM 8 8 GPM 20 IN/HR 1 67 CF/HR/SF 106 SF PROVIDE 964 SF 7��Cl�i�`��7'�,� AUG 0 2 2006 I BY------ Page 1 of 2 PUMPS THE PRO$ USE PUMP !O. Known Capacity Dewatering ---------------- 0 E rvF_______--________� ____-I____ m l ZNEWS Plow (GPM) System Curve GPM TDH 000 1300 21 00.— 13 51 4200 1486 6300 1693 8400 1970 10500 23 13 12600 27 19 Entered GPM 2200 TDH at Entered GPM (tt) 1356 Suggested Pumps ■ Curve Equilibrium GPM 30 22 TDH 1401 Pumps 264 , Sizing ID 36595 Job Number PW-663 Modified 8/1 /2006 4 24 00 PM Job SEA VIEW Address Customer Phone Contact Contractor Address [at - M ■ Curve Equilibrium GPM 47 14 TDH 1630 Pumps 266 267 Back LyBY G 5j 12006 I I _ http //www zoeller com/pumpproselect/webpp_isapr dll/EXEC/36/98279107F96D26525502 8/1/2006 Page 2 of 2 Electrical 220 volt, 1 phase, 60 Hertz Physical Dischage Size (IPS) 200 Pipe Size (IPS) 200 Pipe Length (ft) 250 Type of Pipe Plastic Solids Handling (in) 038 Static Head (ft) 1300 Discharge Press 0 00 psi Fittings Thru Tees Branch Tees 45° Elbows 900 Elbows 4 Gate Valves 1 Check Valves 1 RECET%7 9:`D AUG 07 2 2006 BY http //www zoeller com/pumpproselect/webpp_rsapi dll/EXEC/36/98279107F96D26525502 8/1/2006 rLWITY PUMP6 SNC6 IS�7 N Product infonnaton presented here reflects conditions at time of publication Consult fac tory regarding discrepancies or inconsistencies COMPARE THESE FEATURES Non -Clogging Vortex Impeller Design MAIL TO PO BOX 16347 • Louisville KY 40256 0347 SHIP TO 3649 Cane Run Road Louisville KY 402111961 (502) 778-2731 • 1(600) 926 PUMP FAX (502) 774 3624 • Float operated, submersible (NEMA 6) 2-pole switch • Durable cast iron construction Cast iron switch cap, motor, and pump housing • Engineered plastic base • Stainless steel screws, bolts, handle, guard, arm and seal assembly • Engineered, glass -filled, plastic Impeller with metal insert • UL Listed 3-wire cord and plug 15 fit cord standard for auto- matic & nonautomatic • Corrosion resistant powder coated epoxy finish • Motor - 4 HP 115V & 230V,1 Ph , 60 Hz,1725 RPM, oil filled PSC motor, hermetically sealed, automatic reset thermal overload protection • Upper and lower sleeve bearings running In bath of oil • Carbon and ceramic shaft seal • Passes 2 inch spherical solids • 2" NPT Discharge • On point -12'W Off point - 4'/z" Note The sizing of effluent systems normally requires variable level Float(s) controls and propedyslzed basins to achieve required pumping cycles or dosing timers with nonaulo matic pumps SIMPLEX AND DUPLEX SYSTEMS AVAILABLE SECTION 2 30 015 FM1495 0305 Supersedes 0404 visit our web site www zoeller com 264 SERIES "WASTE -MATE" (For Pump Prefix Identification see News & trews 0052) SUBMERSIBLE SEWAGEIEFFLUENT* V� OR DEWATERING PUMP nesed minsmeac tine 2" NPT DISCHARGE &C .CSP SvgsEcmt!w he SSPMA POWDER MEMBER/ " COATED / TOUGH" sEw p SEW PUW6RS ISW MODELS AVAILABLE • Automatic • Nonautomabc(for variable level systems) BE & BN264 available packaged with Manufacturers of pp I Piggyback variable level float snitch QNLUTY PaMP6 glV- ���,/i] May be used in those states where codes do not restrict solids © Copyright 2005 Zoeller Co All rights reserved AUG 0 2 2006 x a i 0 1< R I - PUMP PERFORMANCE CURVE MODEL 264 TOTAL DYNAMIC HEAD/FLOW SEWAGE AND DEWATERING MODEL 264 Feet Meters Gg23877 iters 5 15 341 10 30 22 15 46 Shut-off Head 18 ft (5 5 m) 6 CM31 20 40 60 80 100 GALLONS LITERS 0 160 320 14 3/4 FLOW PER MINUTE 413116 r 821164 BM2 - CONSULT FACTORY FOR SPECIAL APPLICATIONS Electrical alternators for duplex systems available with vanable level float switches Minimum recommended basin size Simplex-18"00" Duplex-30"x36" Standard Automatic - Weight 34 5 Ibs 4 H P High water alarms available Mechanical alternators available for duplex systems A CAUTION Maximum temperature of sewage or dewatenng must be limited to 130°F (54°C) For over 130°F (54°C) special quotation required 4 13116 I s 35M SK1643 For "M" and "D" models, the approximate gallons pumped out per cycle are Tank Diameter Gallons Pumped 18" Simplex 8 Gallons 24" Simplex 15 Gallons 30" Duplex 22 Gallons 36" Duplex 33 Gallons 48" Duplex 60 Gallons 264 MODELS CONTROL SELECTION Model volts Ph Mode Amps Simplex Duplex M264 115 1 Auto 94 1 4 N264 115 1 Non 94 2or3 4 D264 230 1 Auto 47 1 4 E264 230 1 Non 47 2 or 3 4 SELECTION GUIDE 1 Integral float operated mechanical switch, no external control required 2 For automatic use single piggyback variable level float switch or double piggyback variable level float switch Refer to FM0477 3 See FM1228 for correct model of simplex control panel 4 See FM0712 for correct model of duplex control panel or FM1663 for a residential alternator system For infomalon on adddeal Zoeller products refer to atabg on Pggybeck Vanable level Float Swches FMM77 Ewonal Mannar FM0486 MBdiaral Altemabr FMSump'Serage Sa. FM0437 " Soge Prow Simpler Nr COMrd FM15M Alarm System FM0732 A CAUTION All installation of controls protection devotes and wiring should be done by a qualified licensed electrician All electrical and safety codes should be followed including the most recentslationai Electric Code (NEC) and the Occupational Safety and Health Act (OSHA) RESERVE POWERED DESIGN For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump As MAIL TO PO 025 16347 ` SHIP TO le 49 Cane Ru Re Manufacturers of SHIP is le K Cane Run Road 7182le K 731 1(800) 28 P QuurrPuvae Sezr /939~—` wkvw Zoeller com PUMP !O. (502)7 AX(502)7743624 PUMP I E-4,C F`T' AUG r NCDENR North Carolina Department of Environment and Natural Resources Division of Land Resources James D Simons, PG, PE Land Quality Section Michael F Easley, Governor Director and State Geologist William G Ross Jr , Secretary July 24, 2006 LETTER OF RECEIPT OF EROSION CONTROL PLAN Sea View Investment Group, LLC Brian Dodd, Member 701 Market Street Wilmington, NC 28401 RE Project Name Seaview Project ID Newha-2007-030 County New Hanover, Federal Point, US 421 River Basin Cape Fear Submitted By Stroud Engineering Date Received by LQS July 20, 2006 Plan Type NEW Dear Mr Dodd This office has received a soil erosion and sediment control plan for the protect listed above which was submitted as required by the North Carolina Sedimentation Pollution Control Act (G S 113A-57 (4)) The Act requires that all persons disturbing an area of one or more acres of land must obtain approval of a soil erosion control plan prior to the commencement of the land -disturbing activity (G S 113A-54(d) (4)) The Act further states that this plan must be filed a minimum of 30 days prior to the activity and the approving authority must approve or disapprove the submitted plan within 30 days of receipt Failure of the approving authority to approve or disapprove the submitted plan within the 30-day period will be deemed approval of the plan Commencement or continuation of a land -disturbing activity under the jurisdiction of this Act prior to the approval of an erosion and sediment control plan is a violation of the Act (optional if submittal is not complete) We have performed a preliminary review of your submitted plan and have determined that additional information will be necessary before a final review can be completed Enclosed is a checklist of items that must be submitted before we can complete the review process Failure to provide the additional information may result in disapproval of your plan The approval of an erosion and sediment control plan is conditioned on the applicant's compliance with Federal and State water quality laws, regulations and rules' If you have questions please do not hesitate to contact this office Your cooperation in this matter is appreciated and we look forward to working with you on this project Sincerely, Schuyler Snowdon Env Tech V Land Quality Section cc Luke Menius, Stroud Engineering, P A LQS-WiRO, SWS-WIRO Wilmington Regional Office 127 Cardinal Drive Ext , Wilmington, North Carolina 28405-3845 - Phone 910-796-7215 / FAX 910 350-2004 NORTH CAROLINA DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES LAND QUALITY SECTION EROSION and SEDIMENTATION CONTROL PLAN PRELIMINARY REVIEW CHECKLIST PROJECT NAME Seaview PROJECT NO Newha-2007-030 DATE 7/20/2006 COUNTY New Hanover To expedite the approval process a cursory review of your submitted Erosion and Sediment Control Plan application has been made and has shown the need for additional information as specified below To meet our review schedule, any additional information should be received by this office no later than August 9, 2006 Failure to meet this schedule may result in disapproval of your plan The following Items shall be incorporated with respect to specific site conditions, in an erosion and sediment control plan LOCATION INFORMATION Project location (roads streets landmarks) North arrow and scale GENERAL SITE FEATURES (Plan elements) Legend North arrow scale etc Property lines Existing contours (topographic lines) Proposed contours Limits of disturbed area (provide acreage total delineate limits and label) Planned and existing building locations and elevations Planned & existing road locations & elevations Lot and/or building numbers Geologic features rock outcrops seeps springs wetland and their limits streams lakes ponds dams etc Easements and drainageways Profiles of streets utilities dltchlines etc Stockpiled topsoil or subsoil locations If the same person conducts the land disturbing activity & any related borrow or waste activity the related borrow or waste activity shall constitute part of the land -disturbing activity unless the borrow or waste activity is regulated under the Mining Act of 1971 or a landfill regulated by the Division of Waste Management If the land -disturbing activity and any related borrow or waste activity are not conducted by the same person they shall be considered separate land -disturbing activities and must be permitted either thin the Sedimentation Pollution Control Act as a one use borrow site or through the Mining Act Required Army Corps 404 permit and Water Quality 401 certification (e g stream disturbances over 150 linear feet) EROSION CONTROL MEASURES (on plan) Legend Location of temporary measures Location of permanent measures Constructon drawings and details for temporary and permanent measures Maintenance requirements of measures Contact person responsible for maintenance SITE DRAINAGE FEATURES Existing and planned drainage patterns (include off -site areas that drain through project) Method of determination of and calculations for Acreage of land being disturbed Size and location of culverts and sewers Soil information type special characteristics Soil Information below culvert storm outlets Name and classification of receiving water course (only where stomrwater discharges are to occur) Comments Please include a detail drawing for temporary inlet protection STORMWATER CALCULATIONS Pre -construction runoff calculations for each outlet from the site (at peak discharge points) Design calculations for peak discharges of runoff (including the construction phase & the final runoff coefficients of the site) Design calcs of culverts and storm sewers Discharge and velocity calculations for open channel and ditch flows (easement & n9htof ways) Design calcs of cross sections and method of stabilization of existing and planned channels (include temporary linings) Design talcs and construction details of energy dissipators below culvert and storm sewer outlets (diameters & apron dimensions) Design talcs and dimension of sediment basins Surface area and settling efficiency information for proposed sediment traps and/or basins VEGETATIVE STABILIZATION Area & acreage to be vegetatively stabilized Method of soil preparation Seed type & rates (temporary & permanent) Fertilizer type and rates Mulch type and rates NOTE Plan should include provisions for groundcover on exposed slopes within 15 calendar days, following completion of any phase of grading, permanent groundcover for all disturbed areas within 15 working days or 90 calendar days (whichever is shorter) following completion of construction or development FINANCIAL RESPONSIBILITY/OWNERSHIP FORM Completed signed & notarized FR/O Form Accurate application fee (S50 00 per acre rounded up the next acre with no coiling amount) Certificate of assumed name if the owner is a partnership Name of Registered Agent (if applicable) Copy of the most current Deed for the site NOTE For the Express Permitting Option inquire at the local Regional Office for availability NARRATIVE AND CONSTRUCTION SEQUENCE Narrative describing the nature and purpose of the construction activity Construction sequence related to erosion and sediment control (including installation of critical measures prior to the initiation of the land -disturbing acbvity & removal of measures after areas they serve are permanently stabilized) Bid specifications related only to erosion control AMA NCDENR t r North Carolina Department of Environment and Natural Resources 127 Cardinal Drive, Wilmington NC 28405 (910) 796-7307 FAX (910) 350-2004 ell o PtZt= A-P Request for Express Permit Review FILL-IN all information below and CHECK required Permit(s) FAX or email to Cameron Weaver(ftcmafl net along with a narrative and vicinrtv map of the project location. Projects must be submitted by 9 00 A M of the review date, unless poor arrangements are made. APPLICANT Name Company SEA VIEW INVESTMENT GROUP LLC Address PO BOX 745 City/State KURE BEACH, INC Zip 28449 County NEW HANOVER Phone 910-612-8605 Fax Email PROJECT Name SEA VIEW PROJECT SYSTEM(S) TRIBUTARY TO ATLANTIC OCEAN (STREAM NAME) Cape Fear RIVER BASIN ENGINEERICONSULTANT Company. _ Luke Menufs (7a Stroud Engineering PA Address 102 D Cinema Drive City/State—Wilmington, NC Zip 28403 County New Hanover Phone 910-815-0775 Fax 910-815-0593 Email Imeniusastroudengineercom State or National Environmental Policy Act (SEPA, NEPA) — EA or EIS Required ❑ Yes ® No ❑ STREAM ORIGIN Determination; _# of stream calls, Stream Name ❑ STORMWATER ❑ Low Density ❑ High Density -Detention Pond ❑ High Density -Other Wetlands MUST be addressed below ❑ Low Density -Curb & Gutter ® High Density -Infiltration ❑ Off Site ❑ COASTAL ❑ Excavation & Fill ❑ Bridges & Culverts ❑ Structures Information MANAGEMENT ❑ Upland Development ❑ Marina Development ❑ Urban Waterfront -----------------------------------------------------------------------------------------------------------------------------------------------------------^---�,-p----------- ❑ LAND QUALITY ❑ _ Erosion and Sedimentation Control Plan with acres to be disturbed /�' - ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ WETLANDS (401) Wetlands on Property ❑ Yes ® No Isolated Wetlands on Property ❑ yes ® No Check all that apply Wetlands Will Be Impacted ❑ Yes ® No Wetland Impacts _0_ Acre(s) Wetlands Delineation has been completed ElYes ® No ❑ Buffers Impacted Acre(s) USA COE Approval of Delineation completed ❑ Yes ® No 404 Application in process wIUSACOE ❑Yes ®No 1 Permit received from USACE ❑Yes ®No 401 Application required ❑Yes ® No If Yes, ❑ Regular ❑ Express ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Additional fees, not to exceed 50% of the original Express Review permit application fee, may be charged for subsequent reviews due to the insufficiency of the permit applications For DENR use only SUBMITTAL DATES Fee Split for multiple permits SW $ CAMA $ LQS $ 401 $ Total Fee Amount $ will be infiltrated in 2-5 days via pumping to an infiltration trench The infiltration rate o so is given as >20 inches per hour determine the rate of disposal Erosion Control and Stormwater Project Narrative Sea View PW-653 7/20/06 Project Summary The purpose of this project is to construct residential homes on 1 53 acracr Hof land located Kure Beach, NC at the corner of US 421 and Kure Village Way Nineteen homes ale planned in this development Site Description The topography of the site is essentially flat Existing drainage on site is generally from west to east, towards Fort Fisher Blvd Adjomina Property Adjoining property is primarily residential The site is bordered to the East by Fort Fisher Blvd and to the north by Kure Village Way -- Sods Soils in the project area are mapped in the New Hanover County Soil Survey as Urban A site visit revealed a coarse, sandy spoil type material underlain by material consistent with Newhan Fine Sand This material is afforded rapid (>20 in/hr) infiltration The SMHW was 24" per Vincent Lewis _ Planned Erosion and Sedimentation Control Practices Silt fence will be used extensively around the perimeter of the project to control offsite sedimentation All stormwater inlets will be protected with silt fence as well A temporary gravel construction entrance will be located on the northwestern corner of the project, off Kure Village Way ctices you will be collected and stored in large RCP This volume located in Newhan Fine Sand The pump will ultimately TopoZone - The Web's Topographic Map Page 1 of 1 1wone I � � A5ry NN�Yab. bate ti t i� • • • • 1 • a Into sea so _ ..... ■ . f I A .. . • • S • • -rtgm was ,. i t I �Y �LRIV 4� K ti EACH rf r --= —= ; ;me s ua.4{,6Ig Y l.• :• M1 IQ M, 0 01 02 03 04 05kin t;l 0 0 09 0 18 ' 0 27 0 36 0 45 mi �1pYp1 Map center is 340 00' 28"N, 770 54' 13"W (WGS84/NAD83) Carolina Beach quadrangle M=-8 938 Projection is UTM Zone 18 NAD83 Datum G=-1 625 http //www topozone com/print asp9z=18&n=3766815&e=231848&s=24&size=l&u=6&d 7/20/2006 • $1 MX, - Jun 9 2006 12 22PM : ' STROUD ENGINEERING, P A No 5227 P 1 ,s STROUD ENGINEERING, P.A. Date: 6/9/06 Number of Pages 3 (including cover) To: NC DENR ATTN : VINCENT LEWIS Telephone Number: Facsimile Number: 910-350-2004 E-Mail Address: Reference: SEA VIEW ❑Original will follow via mail Comments: FACSEMnE TRANSMMAL Ey'frass From: LUKE MENIUS Telephone Number: 910-815-0775 Facsimile Number: 910-815-0593 E-Mail Address: lmentuS@stroudengmeer coin ■Original will NOT follow via mail Please find the attached vicinity map and aerial photo of the site. I will plan on meeting you onstte on 6/13 at 9:00. Please let me know if you have any further questions. Luke SeX4V,P,w Sui h as q L # , SLji 11 stioul) bc, rent&vcd S,q„X._ rop 1-k -t IS UAS(d4lc 4rtl k 4 J ?'iiltfi QIY4 -Please call if you experience trouble with this transmittal- VINarir NC MPF-1 6z I L'5 ' pKC1Aus1- ■ 102 D Cinema Drive, Wilmington, NC 28403 910-815-0775 FAX 910-815-0593 0 Jun 9 2006 12 22PM STROUD ENGINEERING, P A No 5227 P 2 I VICINITY, m) don 6/9/9nn6 1 1d 6A PM o� C.00kk lc He Edit View Fayorltes; Tools Help 0 each - 0 Favorites Lj Address In http:/Iwww.googic.comimaphp?hl-en&tab=wl&q= Search X N I WN are fora' Type yoUr ques balo; For be reel Lisa ,a se Salog Was 1] 1 You May also want to'. jmg�= QLLuU News Fro I Maps more QU 1637 Fort Fisher Blvd N, Kure Beach, NC 28449 Search Maps Go 0—b ma4e '-'L - P Search the map FFind businesses Get directions Maps 637 Fort Fisher Blvd PI, Kure Beach. It( 28449 - Gooc le (daps - Microsott Internet Explorer start 6 rl ONE .gyp. `K4 t � y. F a e •- .� !fir d C§ `+^ ��' �' - �. � ' 7 �j zmC�.,�ai;;.ri,- t ,, _iata ri0nF t G o' _ ymantec Anti aus -