HomeMy WebLinkAboutSW8051045_APPROVED PLANS_20190401STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO SWS 6510`FS DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 2 O 1 c 1 D'i o) YYYYMMDD 1 c t POND No.1 OUTLET STRUCTURE DATA BASIN # BOTTOM INLET (ORIFICE) WEIR OUTLET OUTLET INV. IN/ ELEEV. SIZE/INVERT SIZE/INVERT INV. OUT 1 38.00 30.75 2.50/37.0 N/A 24 inch 30.25/30.05 NOTE: WHILE SKIMMER IS FUNCTIONING, CLOSE ALL OPENINGS OF THE OUTLET STRUCTURE EXCEPT THE TOP AND THE INLET (ORIFICE). OUTLET 5" INLET (ORIFICE) PLAN GALV. BAR GRATING - 1"xt/8" BEARING BARS (MAX OPENING 4"). FASTEN WITH TYPE J TOP OF BANK 3 CUPS. ATTACH TO 1-1/4"xt-1/4"xt/4" �1 GALVANIZED ANGLE FRAME. MORTAR FRAME TO TOP OF OUTLET STRUCTURE. -- PVC ORIFICE STUBBED INTO OUTLET STRUCTURE (1) PVC SCREW TYPE PLUG (TOP) (1) PVC TEE OUTLET * L6% 4'-0" �6% *SEE WET DETENTION BASIN & FOREBAY SECTION FOR SLOPE SECTION A - A POND No.2 OUTLET STRUCTURE DATA BASIN # TOP BOTTOM INLET (ORIFICE) WEIR OUTLET OULET INVT IN/ ELEV. ELEV. SIZE/INVERT SIZE/INVERT INV. OUT 2 32.00 25.70 3.00/30.0 N/A 30 inch 25.72/25.29 NOTE- WHILE SKIMMER IS FUNCTIONING, CLOSE ALL OPENINGS OF THE OUTLET STRUCTURE EXCEPT THE TOP AND THE INLET (ORIFICE). ,lllw:ll f7I_1:1 WEIR INLET (ORIFICE) GALV. BAR GRATING - 1"xl/8" BEARING BARS (MAX OPENING 4"). FASTEN WITH TYPE J CUPS. ATTACH TO 1-1/4%1-1/4"x1/4" GALVANIZED ANGLE FRAME. MORTAR FRAME TO TOP OF OUTLET STRUCTURE. -�---- -i PVC ORIFICE STUBBED INTO OUTLET STRUCTURE (1) PVC SCREW TYPE PLUG (TOP) (1) PVC TEE WEIR OUTLET *SEE WET DETENTION BASIN & FOREBAY SECTION FOR SLOPE SECTION A - A WET DETENTION BASIN DATA BASIN # TOP OF BANK TEMPORARY PERMANENT SHWT EMERGENCY I BOTTOM SEDIMENT B''TOM TOP VEG BTM VEG ELEV. POOL ELEV. POOL ELEV. SPILLWAY EL. MAIN/FOREBAY MAIN/FORD AY SHELF SHELF 2 34.00 31.00 30.00 29.50 33.00 25.0/25.0 24.0/2410 31 29 WET DETENTION BASIN DATA TOP OF BANK TEMPORARY PERMANENT EMERGENCY BOTTOM SEDIMENT BOTTOM TOP VEG BTM VEG BASIN # ELEV. POOL ELEV. POOL ELEV. SHWT SPILLWAY EL. MAIN/FOREBAY MAIN/FOREBAY SHELF SHELF 1 40.00 39.00 37.00 36.50 1 39.00 32.0/32.0 31.0/31.0 38.5 36.5 rn :r . : a•d VEG. TOP OF BANK 3 FOREBAY -h .� i - t 3 SHWT $ 3 3 BOTTOM SEDIMENT BOTTOM * POND SLOPE TO BE SEEDED IN ACCORDANCE TO SEEDING SPECIFICATIONS * 3:1 VEGETATED SHELF TO BE PLANTED MATH DROUGHT TOLERANT PLANTS, SEE UST ON SHEET C3 * A PUMP WILL BE PROVIDED TO DRAIN THE BASIN FOR MAINTENANCE AND EMERGENCIES WET DETENTION BASIN & FOREBAY SECTION NTS 8' POND No.3 OUTLET STRUCTURE DATA BASIN # TOP BELEVO.M INLET (ORIFICE) OUTLET OUTLET INV. IN/ ELEV. SIZE/INVERT SIZE/INVERTI S SIZE INV. OUT 3 23.00 14.00 2"/22.0 N/A 30 inch 19.97/19.74 NOTE: WHILE SKIMMER IS FUNCTIONING, CLOSE ALL OPENINGS OF THE OUTLET STRUCTURE EXCEPT THE TOP AND THE INLET (ORIFICE). o j A OUTLET INLET (ORIFICE) 19UN GALV. BAR GRATING - 1"xl/B" BEARING BARS (MAX OPENING 4"). FASTEN WITH TYPE J CLIPS. ATTACH TO 1-1/4"xt-1/4"xl/4" GALVANIZED ANGLE FRAME. MORTAR FRAME TO TOP OF OUTLET STRUCTURE. --, PVC ORIFICE STUBBED INTO OUTLET STRUCTURE (1) PVC SCREW TYPE PLUG (TOP) (1) PVC TEE 4,-0* *SEE WET DETENTION BASIN & FOREBAY SECTION FOR SLOPE SECTION A - A WET DETENTION BASIN DATA BASIN # TOP OF BANK TEMPORARY PERMANENT SHWT EMERGENCY BOTTOM SEDIMENT BOTTOM TOP VEG [BTM VEG ELEV. POOL ELEV. POOL ELEV. SPILLWAY EL. MAIN/FOREBAY MAIN/FOREBAY SHELF SHELF 3 25.00 23.00 22.00 19.00 24.00 17.0/17.0 16.0/16.0 23 21 TOP OF BANK I TOP OF BANK TC R' 0 AARRYY MW --f1 t L_ 3 3 OF�IEG�--------- FOREBAY MAN POOL tL- 3 SHWT $ BOTTOM SEDIMENT BOTTOM 3 3 '.�. BOTTOM I (SEDIMENT BOTTOM * POND SLOPE TO BE SEEDED IN ACCORDANCE TO SEEDING SPECIFICATIONS i * 3:1 VEGETATED SHELF TO BE PLANTED WITH DROUGHT TOLERANT PLANTS, SEE UST ON SHEET C3 f * A PUMP WILL BE PROVIDED TO DRAIN THE BASIN FOR MAINTENANCE AND EMERGENCIES I WET DETENTION BASIN & FOREBAY SECTION NTS I is TOP OF BANK MTTOt7 OF SRELF - - - - - - - - - MAIN POOL 1 FOREBAY 3 SHWr •_ __ -_ 3 3 _- BOTTOM SEDIMENT BOTTOM * POND SLOPE TO BE SEEDED IN ACCORDANCE TO SEEDING SPECIFICATIONS * 3:1 VEGETATED SHELF TO BE PLANTED WITH DROUGHT TOLERANT PLANTS, SEE UST ON SHEET C3 * A PUMP WILL BE PROVIDED TO DRAIN THE BASIN FOR MAINTENANCE AND EMERGENCIES WET DETENTION BASIN & FOREBAY SECTION NTS r MAR 2 8 2111l C5" M o REVISIONS ate I Description I By W C W� w>E zw0 A � E-1 w��p AE-4114p U 0 d' CO W O W Q) U zFrri 0 co \.J Ul o tn O I la co. P4 z W ^ on O O a W W Z N O Oa Q N W 0) 0 N" E+ r 0, ��``UltfuUrrrri��i A SEAL 17374 (� X/''•�1GINEEf� OREGORyo``, DATE 03-27-19 DESIGN PGT DRAWN EJW SHEET 4 OF 4 16029 2' MP^lun P r`n%/f7P 8' PIPE SECTION -S !UNCTION BOX ELEVATIONS BOX# RIM INVERT OUTLETSIZE PIPESECTION 1 35.00 31.50 24" 24" 2 35.00 31.50 24" 24" 3 32.00 29.00 24" 30" 4 34.00 31.00 24" 24" PIPE SECTION SECTION RIP RAP AT END OF PIPE SECTIONS ARE 5' X 10' JUNCTION BOX DETAIL NTS OUTLET T NOTE WHILE SKIMMER IS FUNCTIONING, CLOSE ALL OPENINGS OF THE OUTLET STRUCTURE EXCEPT THE e 6' 0* I' TOP AND THE INLET (ORIFICE). PLAN GALV. Hot GRATING - 1"xt/5" BEARING BARS (MAX OPENING 5"). FASTEN WITH TYPE J CUPS. ATTACH TO 1-1/4"x1-1/4"x1/4" 1 GALVANIZED ANGLE FRAME MORTAR FRAME TO TOP OF OUTLET STRUCTURE. NOTE 1) ALL MATERIALS TO BE NON -CORROSIVE Trom 2) OUTLET STRUCTURE TRASH RACK TO COVER I TOP, SIDES AND WEIR OPENINGS I *SEE WET DETENTION BASIN k FOREHAY SECTION FOR SLOPE SECTION A — A WET DETENTION BASIN OUTLET STRUCTURE NTS ARM ASSEMBLY \ "C" ENCLOSURE I UF' VILvv WATER ENTRY UNIT SCEHDULE 40 PVC PIPE VENT \ / PVC PIPE PVC END CAP , PVC ELBOW SCHEDULE 40 PVC TEE PVC END CAP PVC PIPE PVC PIPE J" HOLES IN UNDERSIDE FLEXIBLE HOSE CONNECTED TO ORIFICE \ / END VIEW e FRONT VIEW ` ORIFICE PLATE PVC TEE POND No. 1: 3" SKIMMER W/2" ORIFICE POND No. 2: 3" SKIMMER W/2 ORIFICE POND No. 3: 3" SKIMMER W/2 ORIFICE POND No. 4: 3" SKIMMER W/2" ORIFICE BAFFLE CONSTRUCTION SPECIFICATION: 1. GRADE THE BASIN SO THAT THE BOTTOM IS LEVEL FRONT TO BACK AND SIDE TO SIDE. 2. INSTALL THE COIR FIBER BAFFLES IMMEDIATELY UPON EXCAVATION OF THE BASINS. 3. INSTALL POSTS ACROSS THE WIDTH OF THE SEDIMENT TRAP. 4. STEEL POSTS SHOULD BE DRIVEN TO A DEPTH OF 24 INCHES AND SPACED A MAXIMUM OF 4 FEET APART. THE TOP OF THE FABRIC SHOULD BE 6 INCHES HIGHER THAN THE INVERT OF THE SPILLWAY. TOPS OF BAFFLES SHOULD BE 2 INCHES LOWER THAN THE TOP OF THE EARTHEN EMBANKMENT. 5. INSTALL AT LEAST THREE ROWS OF BAFFLES BETWEEN THE INLET AND OUTLET DISCHARGE POINT. BASINS LESS THAN 20 FEET IN LENGTH MAY USE 2 BAFFLES. 6. ATTACH A 9 GAUGE HIGH TENSION WIRE STRAND TO THE STEEL POSTS AT A HEIGHT OF 6 INCHES ABOVE THE SPILLWAY ELEVATION WITH PLASTIC TIES OR WIRE FASTENERS TO PREVENT SAGGING. IF THE TEMPORARY SEDIMENT BASIN WALL BE CONVERTED TO A PERMANENT STORMWATER BASIN OF A GREATER DEPTH, THE BAFFLE HEIGHT SHOULD BE BASED ON THE POOL DEPTH DURING USE AS A TEMPORARY SEDIMENT BASIN. 7. EXTEND 9 GAUGE MINIMUM HIGH TENSION WIRE STRAND TO SIDE OF BASIN OR INSTALL STEEL T-POSTS TO ANCHOR BAFFLE TO SIDE OF BASIN AND SECURE TO VERTICAL END POSTS. 8. DRAPE THE COIR FIBER MAT OVER THE WIRE STRAND MOUNTED AT A HEIGHT OF 6 INCHES ABOVE THE SPILLWAY ELEVATION. SECURE THE COIR FIBER MAT TO THE WARE STRAND WITH PLASTIC TIES OR WARE FASTENERS. ANCHOR THE MATTING TO THE SIDES AND FLOOR OF THE BASIN 'NTH 12 INCH WIRE STAPLES, APPROXIMATELY 1 FT APART, ALONG THE BOTTOM AND SIDE SLOPES OF THE BASIN. 9. DO NO SPLICE THE FABRIC, BUT USE A CONTINUOUS PIECE ACROSS THE BASIN. 10. ADJUSTMENTS MAY BE REQUIRED IN THE STAPLING REQUIREMENTS TO FIT INDIVIDUAL SITE CONDITIONS. SUPPORT ROPE, TO WIRE TO //-SUPPORT POST -,STAKE TO SUPPORT PREVENT SAGGING /24" INTO BOTTOM WIRE OR SIDE \-COIR MESH OR SIMILAR, STAPLES OR TRENCHED INTO BOTTOM OR SIDE CROSS SECTION OF POROUS BAFFLE NTS POROUS BAFFLE DATA BASIN # # OF BAFFLES SPACING BETWEEN BAFFLES 1 3 20' 2 3 15' 3 3 30' 4 3 hamb r e n.'. mbe f'Id,:.eu $11 ct. .eart: •il-t mne ,, , of ;wa,, or Sbpn Drnr, rt fir st bltd } Babb, I Figure 6.66a Porous bafllea in a sedirnerri basin. The 11, s f1bYr0.1ev evenly aron's the basin to reduce now rates one wrUulence, resulting in greeter sedrma eta�n OUTLET STRUCTURE DATA BASIN / E EPV BOTTOM INLET SI (ORIFICE) OUTLET OUTLET IINV NV. OUT 1 35.00 3200 24"/320 24" 32.0 2 35.00 3200 24"/320 24" 32.0 3 33.00 30.00 24"/30.0 W. 3G0 4 35.00 32.00 24"/32.0 24" 320 �r POND No. 1 SCALE 1"=30' POND No. 3 SCALE 1"=30' POND No. 2 SCALE 1"=30' I I I I POND No. 4 SCALE 1"=30' REVISIONS Descriptior REVISE POND Off REVISE POND DUfF z 1-4 1.4 �\4 O o 0 FT H Vl a o F2 Ld 0 11 r , r� O N Q cd z O O CO P-4 L CO / y O I Ia a I 3 _ a �ooW. o � CID M M� 1- a Q) E­4 ^y O a AINJ . cm \ S E A L - 17374 GREGOR6\\`\ /unn111� DATE 03-14-19 DESIGN PGT DRAWN EJW Z c 9 SHEET 9 OF 15 17030 F N C G S_ mnN[JMFNT / N.C.G.S. MONI "POLE" N 89171.8722 E 2237525.1 E rI r r c 0 { r r rr l LINE I BEARING DISTANCE L46 I S09'19'59"W 24.57 CURVE BEARING CHORD LENGTH RADIUS C1 N08-42-10"E I 53.80 53.94 215.00 C2 N12'37'01"E 117.05 117.12 1025.00 N/F SIMMONS / / i / i / / / / / / / / I EaEN c EXISTING IRON PIPE W W W W WETLAND W W OWNER - PALMETTO CREEK, LLC 6740 NETHERLANDS DRIVE SUITE F WILMINGTON, NC 28405-0000 PHONE: (910)452-7175 DRAWN : PROJECT 150-00 NUMBER DESIGN : CHECK : SCALE : 1'=100' APPROVED : DATE : 20 Feb 06 FlLE NAME The Reserve at Palmetto Creek Wetland Map JOB NUMBER SHEET NUMBER 150— 00 1 1 for r-40 �. - Am bmitta/ Brunswicl� County, North Caro/ina coastal hand Desi PLLC Civil Engineering / Landscape Architecture / Construction Management P.O.Box 1172 Wilmington, NC 28402 Phone: 910-254-9333 Fax:910-254-0502 OWNER: PALMETTO CREEK, L.L.C. 6740 NETHERLANDS DRIVE, SUITE F WILMINGTON, NC 28405 (910) 452 - 7175 (910) 452 - 2135 (FAX) BRUNSWICK COUNTY NORTH CAROMNA 211 � Supply JSN �t NORTH Concord Church kNood Fo\\y R��er \ hoc Old on Rd ' S ,1504 SITE oo�ponsu °pIYRd,A,C2 II LOCATM MAP B#K#AMWk'aK 001b IY, NIOIH'M CARi01lM NOT TO SCALE / SHEETINDEX SWA STORMWATER SYSTEM MANAGEMENT PLAN: SHEET 1 SW-2 STORMWATER SYSTEM MANAGEMENT PLAN: SHEET 2 SW-3 STORMWATER SYSTEM CONSTRUCTION DETAILS: SHEET 1 SW-4 c;TORMWkTER S YSTEM CONSTRUCTION DETAILS: SHEET 2 (C� VED � A AppRO NOAINCA EMENTOOMMISSION AL MANAG DMS I 0� Sw CREVREV-3 NCDENR—DWQ. SWS 051045 JR C —STORMWATER COMMENTS 1 04/13/08 SW8 051TSS JRC REV—2 NSTO04 RMWATER 03/06/06 NCDENR—DWQ: SW8 051045. JRC REV—i STORMWATER COMMENTS 02/14/06 NpO1MyNIb �3/Ob — 6 e4A 0H4.,, ISSUED NCDENR-DWO FOR REVIEW iy'� �FEssio� 31- JAWAW-2006 SEAL 028858 u NCDENR-LOS APPROVAL -098 21-OCTOBER-2005 1-OCTOBM PRELIMINARY DESIGN NOT RELEASED FOR CONSTRUCTION A v ) 1 I-- Q:�. � ;CD J o / ,z i whau GRAPHIC SCALE I , I I-4 ( IN FEET) 1 inch = 50 ft —ff PRELIMINARY DESIGN NOT RELEASED FOR CONSTRUCTION_ 187' TT0 to F RF . . . w z R / lei .C 107• 2 Cx Yr�O =43 _ � ` 107' _ l - 187' �'� / / 18T �> > POND-1 F01RE13AY- 32 120 F I / 0, 30 I.J`{aBtD� APPROXIMATE • WETLAND LOCATION -- -- EXIST. MAJOR CONTOUR - -- EXIST. MINOR CONTOUR --C1UL-kt44.- EXIST. PROPERTY BOUNDARY 38 PRO. CONTOUR ----------- PRO. LOT LINE PRO. EDGE OF PAVEMENT PRO. BACK OF CURB ------- PRO. ROAD CENTERLINE -"- -"- - - PRO. RIGHT OF WAY - - - - - - - - - - PRO. EASEMENTS PRO. STORMWATER LINE PRO. SIDEWALK PRO. DRAINAGE BASINS PRO. HIGH / LOW POINTS (---. PRO. FLOW DIRECTION C1341 PRO. DRAINAGE BASINS BUILT UPON CALCULATIONS OVERALL AREA: TOTAL PROJECT AREA = 42.41 AC. DEDUCTED WETLAND = —0— TOTAL USABLE AREA = 42.41 AC. IMPERVIOUS AREA: RESIDENTIAL BUILDINGS = 10.59 AC. STREETS AND ROADWAY = 3.25 AC. EXTRA PARKING = 1.52 AC. SIDEWALK = 0.58 AC. AMENITY CENTER = 0.04 AC. TOTAL = 15.97 AC. PROJECT DENSITIES: 15.97 AC. 42.41 AC. REV. — S 04 OJ RC 3 STORMWATER COMMENTS 04/13/06 REV. NCDENR—DWO: SW8 051045 JRC 2 STORMWATER COMMENTS 03/08/06 REV. NCDENR—DWO: SW8 051045 JRC 1 STORMWATER COMMENTS 02/14/O6 REV. DESCRIPTION Y DA REVISIONS OWNER: PALMETTO CREEK, L.L.C. 6740 NETHERLANDS DRIVE, SUITE F WILMINGTON, NC 28405 (910) 452 — 7175 (910) 452 — 2135 (FAX) Coastal Land Design, PLLC Civil Engineering / Landscape Architecture / Construction Management P.O.Box 1172 Phone: 910-254-9333 Wilmington, NC 28402 Fax: 910-254-0502 DRAWN : J. CARMINE PROJECT - �, DESIGN J. CARMINE NUMBER : 150-01 ��-, - -- A � // . � CHECK : J. PETROFF SCALE : 1' = 50' APPROVED : J. PETROFF DATE : 31-JAN-2006 FlLE NAME 55 ?3 NOTE: NORMAL CROWN OF 1/4" PER PAVEMENT DESIGN FOOT UNLESS OTHERWISE DIRECTED. 2• 1-2 6" A.B.C. TYPICAL STREET SECTION NOT TO SCALE 24" ROLL CURB St GUTTER ( IN FEET ) I inch = 50 ft. LINE TABLE LINE LENGTH I BEARNIG L17 337.87 N7432'24'W Ll e. N153325-E L79 N3524744-E L20 30.23 N15b325"E L21 67.54 N01'30'55-E L22 59.58 NO13O'38'E L23 54.48 N15W25-E N2412 20 E L25 349.01 N25-14'18-E L26 4522 N6523'41'E N45-0916E 97.70 N3112'2/'E L29 &71 N1411'12-E L30 244. N201407-E L31 53Z77 S69'43'S3'E 60. 502'29 DYW L33 340.40 N74.3224W L34 20295 N0017'32E L35 137.7 N602/'32'W N25V 59-W N512857-W L38 135.42 SSWOfl9"W L39 73.88 S3822'07-W S165P5YW 41 1. 512'0fO9-W L116 202.98 N0017'31'E L117 137.73 N60'21'32'W L118 158.72 N25ro559-W 11 4 N51 57'W L1 135.42 S89W'19'W L721 73. 53822'07'Y/ L12 9.37 515'31'5YW LIZ4 1 121.50S12101'09^M CURVE TABLE CURVE DELTA RADIUS i ARC CHORD I TANGENT CHORD ORO 19'3116' 15.0000 28.9611 20.11212 14.6223S25391V 193118 11 .1 4 1 . N2S39'E C3 1422.30" 215.0000 53.9416 53.8002 27.1132 NO8'42'E C4 14M'47' 20. 20.7860 /0.4716 50852W 6'32475' 1 11 .1 6 N1237E 133023 1 98ro6W C7 71373B- 0000 50237 470.0055 2W4068 70-4 VV GENERAL NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING UTILITIES, ABOVE AND BELOW GROUND, PRIOR TO COMMENCING CONSTRUCTION. 2. CONTRACTOR IS RESPONSIBLE FOR DISPOSAL OF ALL WASTE MATERIALS GENERATED THROUGH DEMOLITION AND GRUBBING ACTIVITIES. 3. THE AREAS OF ENVIRONMENTAL CONCERN AS SHOWN ON THIS MAP WERE DELINEATED BY GARY MITCHEL OF THE CLARK ENVIRONMENTAL GROUP AND DELIVERED TO COASTAL LAND DESIGN IN OCTOBER, 2005. 4. THE DISTURBANCE FOR THIS SITE IS TO BE KEPT TO A MINIMUM. 5. ALL DISTURBED AREAS NOT WITHIN THE PROPOSED BACK OF CURB (BOC) TO BE SEEDED, FERTILIZED, AND MULCHED WITHIN 15 CALENDAR DAYS OF GRADING ACTIVITIES. 6. ALL STORMDRAIN DEVICES ARE TO PROVIDE POSITIVE DRAINAGE. 7. EROSION AND SEDIMENTATION CONTROL PRACTICES ARE TO REMOVED IN THE LOCATION THAT THE STORMWATER SYSTEM IS BEING INSTALLED AT THAT TIME. 8. STORMWATER PUMPS ARE TO BE PROVIDED FOR OPERATION AND MAINTENANCE AND EMERGENCY DRAINAGE OF EACH POND. TYPICAL CUL-DE-SAC NOT TO SCALE I ! ' I I r I 1 � l i i I I Ao, as l i i i RTW ! I I I i OFFSET CUL-DE-SAC NOT TO SCALE Su% APPROXIMATE WETLAND LOCATION - --- ---- EXIST. MAJOR CONTOUR - - - `-' - -- EXIST. MINOR CONTOUR --ML-LW4-- EXIST. PROPERTY BOUNDARY 38 PRO. CONTOUR --- PRO. LOT LINE PRO. EDGE OF PAVEMENT PRO. BACK OF CURB ------- PRO. ROAD CENTERLINE - -...... - PRO. RIGHT OF WAY - - - - - - - - - - PRO. EASEMENTS PRO. STORMWATER LINE PRO. SIDEWALK PRO. DRAINAGE BASINS PRO. HIGH / LOW POINTS PRO. FLOW DIRECTION C841 PRO. DRAINAGE BASINS OVERALL AREA: TOTAL PROJECT AREA = DEDUCTED WETLAND = 42.41 AC. -0- TOTAL USABLE AREA = IMPERVIOUS AREA: 42.41 AC. RESIDENTIAL BUILDINGS = STREETS AND ROADWAY = EXTRA PARKING = SIDEWALK = AMENITY CENTER = 10.59 AC. 3.25 AC. 1.52 AC. 0.58 AC. 0.04 AC. TOTAL = PROJECT DENSITIES: 15.97 AC. 15.97 AC. (100) = 37.7 42.41 AC. REV. 3 - 04 STORMWATER COMMENTS C 04/13/06 REV. 2 NCDENR-DWQ: SW8 051045 STORMWATER COMMENTS JRC 03/08/06 REV. 1 NCDENR-DWQ: SW8 051045 STORMWATER COMMENTS JRC 02/14/06 R#V. DESCRIPTION Y DATE REVISIONS OWNER: PALMETTO CREEK, L.L.C. 6740 NETHERLANDS DRIVE, SUITE F WILMINGTON, NC 28405 (910) 452 - 7175 (910) 452 - 2135 (FAX) Coastal sand Design, PLLC Civil Engineering / Landscape Architecture / Construction Management P.O.Box 1172 Phone: 910-254-9333 Wilmington, NC 28402 Fax: 910-25"502 DRAWN : J. CARMINE PROJECT DESIGN : J. CARMINE NUMBER ; 150-01 CHECK : J. PETROFF SCALE : 1" = SO, APPROVED : J. PETROFF DATE : 31-JAN-2006 FlLE NAME : t THE RESERVE AT PALMETTO CREEK STORMWATER SYSTEM MANAGEMENT PLAN JOB NUMBER SHEET NUMBER 150-01 SW-2 OUTFLOW PIPE FRAME & GRATE FOOTING (TYP.) FRAME & GRATE OUTFLOW PIPE FOOTING - #4 BARS ® 12"O.C. EACH WAY 6" #57 WASHED STONE PLAN i %i ,/. rn w /10 j % 1i fy > 10 SECTION CATCH BASIN NOT TO SCALE a 0 30" RING & COVER -BIT. PAVEMENT & BASE COURSE ECCENTRIC CONE ,,-MANHOL STEP (TYP.) RUBBER GASKET MID.) 4'-0" 1'-0" MIN. CRUSHED-,*% STONE PRECAST JUNCTION BOX NOT TO SCALE Pipe Number Upstream Basin Downstream Basin UBasin-DBasin Pipe Name Pipe Len th Pipe Slope Downstream Inv. In Upstream Inv. Out Upstream Rm Pipe Size Upstream Pi e Cover no name [name] name it /o ft ft 1 1#1 11-ni [ft 1 JB02 FES01 JB02-FES01 37.5 0.20 35.87 35,94 44.0 24 6.1 2 JB03 JB02 JB03-JB02 51.5 0.20 35.94 36.04 43.5 24 5.5 3 CB04 JB03 CB04JBO3 175.8 0.20 36.04 36.39 43.5 24 5.1 4 JB05 CB04 JB05-CB04 159.5 020 36.39 36.71 43.0 24 4.3 5 CB06 JB05 CB06JB05 116.0 0.20 36.71 36.95 41.0 24 2.1 6 CB07 CB06 CB07-CB06 22.3 0.20 36.95 36.99 41.0 24 2.0 7 CB08 JB02 CB08JBO2 127.1 0.20 35.94 36.19 41 24 3.3 8 CB14 JB03 CB14JB03 134.8 0.20 36.04 36.31 1 40.5 24 2.2 9 CB18 CB04 CB18-CB04 27.7 0.20 36.39 36.45 43.5 24 5.1 10 CB10 CBO8 CB1O-CB08 158.7 0.20 36.19 36.51 43.0 24 4.5 11 CB15 CB14 CB15-CB14 22.3 0.20 36.31 36.36 405 24 2.1 12 CB19 CB18 C619-CB18 183.1 0.20 36.45 36.82 42.5 24 3.7 13 CB12 CB10 CB12-CB10 125.3 0.20 36.51 36.76 42.0 24 3.2 14 CB16 C815 CB16-CB15 49.1 1 0.20 36.36 36.46 39.0 24 0.5 15 CB13 CB12 CB13-CB12 29.9 020 36.76 36.82 42.0 24 3.2 16 CB17 CB16 CB17-CB16 22.3 0.20 36.46 36.50 1 39.0 24 0.5 17 CB09 CB08 CB09-CB08 22.3 0.20 36.19 36.24 1 41.5 24 3.3 18 CB11 CB10 CB11-CB10 22.3 0.20 36.51 36.56 42.0 24 3.4 19 JB21 FES20 JB21-FES20 147.0 0.25 29.00 29.37 35.5 24 4.1 20 JB22 JB21 JB22-JB21 184.6 0.25 29.37 29.83 37.9 24 6.1 21 JB23 JB22 JB23-JB22 74.2 0.50 29.83 30.20 39.5 24 7.3 22 SWP1 JB23 SWPiJB23 109.4 0.50 30.20 30.75 38.0 24 5.3 23 JB25 FES24 JB25-FES24 2242 2.75 24.00 30.17 41.3 30 8.6 24 CB26 JB25 CB26JB25 60.7 1.00 30.17 30.77 40.0 30 6.7 25 CB28 CB26 CB28-CB26 127.5 1.00 30.77 32.05 1 37.8 30 3.2 26 CB30 CB28 CB30-CB28 90.1 0.75 32.05 32.72 37.8 24 3.0 27 CB32 CB30 CB32-CB30 110.8 0.50 32.72 33.28 39.0 24 3.7 28 CB34 CB32 CB34-CB32 147.0 0.50 33.28 34.01 40.8 24 4.7 29 CB36 CB34 CB36-CB34 122.0 1 0.50 34.01 34.62 42.0 24 5.4 30 CB37 CB36 CB37-CB36 22.6 0.50 34.62 34.74 42.0 24 1 5.3 31 CB38 JB25 CB38J825 141.7 0.50 30.17 30.87 40.8 24 1 7.9 32 CB27 CB26 CB27-CB26 22.3 0.50 30.77 30.88 40.0 24 1 7.1 33 CB29 CB28 CB29-CB28 22.1 0.50 32.05 32.16 37.8 24 1 3.6 34 CB31 CB30 CB31-CB30 22.4 0.50 32.72 32.84 1 37.8 24 1 2.9 35 CB33 CB32 CB33-CB32 22.3 0.50 33.28 33.39 40.8 24 1 5.4 36 CB35 CB34 CB35-CB34 22.3 0.50 34.01 34.12 42.0 24 1 5.9 37 CB39 CB38 CB39-CB38 22.2 0.50 30.87 30.99 40.8 24 1 7.8 38 JB41 FES40 JB41-FES40 167.3 1.00 24.00 25.67 34.0 30 1 5.8 39 CB42 JB41 CB42-JB41 147.2 0.75 25.67 26.78 38.0 24 9.2 40 CB43 CB42 CB43-CB42 22.3 0.75 26.78 26.94 38.0 24 9.1 41 CB44 CB43 CB44-CB43 113.6 0.75 26.94 27.80 42.0 24 12.2 42 CB46 CB44 CB46-CB44 136.6 0.75 27.80 28.82 43.0 24 12.2 43 CB48 CB46 CB48-CB46 147.9 0.50 28.82 29.56 41.5 24 9.9 44 CB50 CB48 CB50-CB48 1912 1 0.50 29.56 30.52 41.0 24 8.5 45 CB52 CB50 CB52-CB50 112.1 1 0.50 30.52 31.08 40.5 24 7.4 46 CB55 CB43 CB55-CB43 116.2 0.50 26.94 27.52 35.0 24 1 5.5 47 CB45 CB44 CB45-CB44 22.3 0.50 27.80 27.91 42.0 24 1 12.1 48 CB47 CB46 CB47-CB46 22.3 0.50 28.82 28.93 43.0 24 1 12.1 49 CB49 CB48 CB49-CB48 22.3 0.50 29.56 29.67 41.5 24 9.8 50 CB51 CB50 CB51-CB50 22.3 0.50 30.52 30.63 41.0 24 8.4 51 CB53 CB52 CB53-CB52 104.1 0.50 31.08 31.60 39.0 24 1 5.4 52 CB56 CB55 CB56-CB55 22.3 1 0.50 27.52 27.64 35.0 24 1 5.4 53 CB54 CB53 CB54-CB53 22.3 1 0.50 31.60 31.71 39.0 24 1 5.3 54 CB59 FES58 CB59-FES58 143.9 3.50 17.00 22.04 30.5 30 6.0 55 CB60 CB59 CB60-CB59 23.0 1.00 22.04 22.27 30.5 30 5.7 56 CB61 CB60 CB61-CB60 112.3 1.00 22.27 23.39 34.0 24 8.6 57 JB63 CB61 J663-CB61 96.3 1.00 23.39 24.35 35.0 24 8.6 58 CB64 J863 CB64JB63 90.8 1.00 24.35 25.26 32.0 24 4.7 59 CB66 CB64 CB66-CB64 132.7 0.50 25.26 25.92 30.8 24 2.8 60 CB67 CB66 CB67-CB66 22.1 0.50 25.92 26.03 30.8 24 2.7 61 CB68 CB67 CB68-CB67 226.1 0.50 26.03 27.16 31.8 24 2.6 62 CB69 CB68 CB69-CB68 22.4 0.50 27.16 27.28 31.8 24 2.5 63 CB70 CB60 CB70-CB60 115.0 1.00 22.27 23.42 34.1 24 8.7 64 C862 CB61 CB62-CB61 22.2 1.00 23.39 23.61 34.0 24 8.4 65 CB65 CB64 CB65-CB64 22.3 1.00 25.26 25.48 32.0 24 4.5 66 CB72 CB70 CB72-CB70 166.6 1.00 23.42 25.08 36.0 24 8.9 67 CB73 CB72 CB73-CB72 22.2 1.00 25.08 25.30 36.0 24 8.7 68 CB71 CB70 CB71-CB70 1 22.2 1.00 23.42 23.64 34.1 1 24 1 8.5 PIPING SCHEDULE DETAIL NOT TO SCALE 34.00 3 20' 11111111111�1 .32.50 34.00 EMERGENCY SPILLWAY NOT TO SCALE TYPICAL CONC. FLARED END SECTION L DO = PIPE DIA LA = APRON LENC W = APRON WIDTH 3 X PIPE 4 MIN D = APRON DEPTH PIPE DIA. i ISOMETRIC VIEW PLAN E NOTE: HORIZONTAL STAPLE SPACING SHOULD BE ALTERED IF NECESSARY TO ALLOW STAPLES TO SECURE THE CRITICAL POINTS ALONG THE CHANNEL SURFACE. REFER TO GENERAL STAPLE PATTERN GUIDE FOR CORRECT STAPLE RECOMMENDATIONS FOR CHANNELS. 2 1. PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING APPLICATION OF LIME, FERTILIZER, AND SEED. 2. BEGIN AT THE TOP OF THE CHANNEL BY ANCHORING THE BLANKET IN A 6" DEEP X 6" WIDE TRENCH. ' BACKFlLL AND COMPACT THE TRENCH AFTER STAPLING. • • • • • • • • _ :. • ' :::::: 3. ROLL CENTER BLANKET IN DIRECTION OF WATER FLOW ON BOTTOM OF CHANNEL. r ' • • ' 4. PLACE BLANKETS END OVER END (SHINGLE STYLE) WITH A 6" OVERLAP. USE A DOUBLE ROW OF' }�"' i• r�� rr3 ::: • STAGGERED STAPLES 4" APART TO SECURE BLANKETS. •� . •. 5 5. FULL LENGTH EDGE OF BLANKETS AT TOP OF SIDE SLOPES MUST BE ANCHORED IN 6" DEEP X 6" WIDE • r ' TRENCH. BACKFlLL AND COMPACT THE TRENCH AFTER STAPLING. , , ,� t :::: • •, �•� t 6. BLANKETS ON SIDE SLOPES MUST BE OVERLAPPED 4" OVER THE CENTER BLANKET AND STAPLED W i ; ; ; , •• ••• (2" FOR C350 MATTING). �* ^�:� •� •• 7. IN HIGH FLOW CHANNEL APPLICATIONS, A STAPLE CHECK SLOT IS RECOMMENDED AT 30 TO 40 FOOT INTERVALS. USE A ROW OF STAPLES 4" APART OVER ENTIRE WIDTH OF THE CHANNEL. PLACE A " ,i�'ra „ a+'3',� �'� �•- _ SECOND ROW 4" BELOW THE FIRST ROW IN A STAGGERED PATTERN. ry'•.. ' ::::.... 7 8. THE TERMINAL END OF THE BLANKETS MUST BE ANCHORED IN A 6" DEEP X 6" WIDE TRENCH. �. ' ' ' ' • BACKFlLL AND COMPACT THE TRENCH AFTER STAPLING. 9. CHANNEL INSTALLATION GRAPHICS AND NOTES ARE FROM NORTH AMERICAN GREEN. 4 A B C CRITICAL POINTS SPILLWAY MATTING INSTALLATION A. OVERLAPS AND SEAMS NOT TO SCALE B. PROJECTED WATER LINE `..x::>': NOTES: SEE APPROPRIATE SCHEDULE FOR DIMENSIONS 1. LA IS THE LENGTH OF THE RIPRAP APRON. 2. D = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6" 3. A FILTER BLANKET OR FILTER FABRIC SHOULD BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. RIP -RAP AT FLARED END SECTION NOT TO SCALE NOTES: 1. CONCRETE 4,000 PSI MINIMUM. 2. REINFORCING STEEL ASTM A-615 GRADE 60. 3. MEETS N.C.D.O.T. APPROVAL TO 10' DEPTH. 4. SOLID BOXES MEET H-20 LOADING TO 15' DEPTH, 5. PRECAST BOXES APPROVED FOR N.C.D.O.T. STANDARDS: 840.01, 840.02, 840.04, 840.05, HEIGHT 840A1, 840.12, 840.14, 840.15, 840.17, VARIES 840.18, 840.19, 840.26, 840.27, 840.28, 840.31, 840.32, and 840.41. 6. ANY MODIFICATION TO BOX MAY NULLIFY H-20 LOADING ABILITY. I--12' NG HOLES (4 each) 4S' x 480 PRECAST CONCRETE WAFFLE BOX NOT TO SCALE L REVERSE SECTION NOT TO SCALE F L STANDARD SECTION ROLL CURB AND GUTTER NOT TO SCALE C. CHANNEL BOTTOM/SIDE A SLOPE VERTICES B C PRELIMINARY DESIGN i NOT RELEASED FOR CONSTRUCTION n e n,i nr n„nn PLAN STANDARD 24" ROLL CURB FRAME AND GRATE to SECTION X-X �i SECTION Y-Y CURB INLET NOT TO SCALE 4.25" LFMEND APPROXIMATE WETLAND LOCATION - - - EXIST. MAJOR CONTOUR - - EXIST. MINOR CONTOUR -SYAi-1194 - EXIST. PROPERTY BOUNDARY 38 PRO. CONTOUR PRO. LOT LINE PRO. EDGE OF PAVEMENT PRO. BACK OF CURB - - - - - - - PRO. ROAD CENTERLINE -' - - - - - PRO. RIGHT OF WAY - - - - - - PRO. EASEMENTS PRO. STORMWATER LINE PRO. SIDEWALK PRO. DRAINAGE BASINS PRO. HIGH / LOW POINTS - PRO. FLOW DIRECTION C641 PRO. DRAINAGE BASINS BUILT UPON CALCULATIONS OVERALL AREA: TOTAL PROJECT AREA = 42.41 AC. DEDUCTED WETLAND = -a- TOTAL USABLE AREA = 42.41 AC. IMPERVIOUS AREA: RESIDENTIAL BUILDINGS = 10.59 AC. STREETS AND ROADWAY = 3.25 AC. EXTRA PARKING = 1.52 AC. SIDEWALK = 0.58 AC. AMENITY CENTER = 0.04 AC. TOTAL = 15.97 AC. PROJECT DENSITIES: 15.97 AC. (100) = 37.7 42.41 AC. REV. - S 104 RC 3 STORMWATER COMMENTS 04/13/06 REV. NCDENR-DWQ: SW8 051045 JRC 2 STORMWATER COMMENTS 03/08/06 REV. NCDENR-DWQ: SW8 051045 JRC 1 STORMWATER COMMENTS 02/14/06 REV. DESCRIPTION Y SATE RFVICI(1MC 1 OWNER: PALMETTO CREEK, L.L.C. 6740 NETHERLANDS DRIVE, SUITE F WILMINGTON, NC 28405 (910) 452 - 7175 (910) 452 - 2135 (FAX) Coastal Land Design, PLLC Civil Engineering / Landscape Architecture / Construction Management P.O.Box 1172 Phone: 910-254-9333 Wilmington, NC 28402 Fax: 910-254-0502 DRAWN a CARMINE PROJECT 150-07 NUMBER ; DESIGN J. CARMINE CHECK : J. PETROFF SCALE : NOT TO SCALE APPROVED : J. PETROFF DATE : 31-JAN-2006 FILE NAME : THE RESERVE AT PALMETTO CREEK STORMWATER SYSTEM CONSTRUCTION DETAILS JOB NUMBER SHEET NUMBER 150-01 SW-3 } FORESLOPE - FG: 40.00' FORESLOPE - - FG: 34.00' FORESLOPE FG: 24.00' SEDIMENT FOREBAY TEMP. POOL ELEV: 38.50' TOP OF n cv. t-r nn' MAIN POND .r Y rr • r rr ,uuu.�,�1.ur� r • i A firfirfidilrrJri�-i. 0- WATER LEVEL: 38.00' FOREBAY WEIR J�/\\/ AP APRON /�\\//\\/ ,�/`//� /\ PERMANENT POOL 24- HDPE SPILLWAY PIPE E'A ELEV: Y BOOTOTOM �\/ /{�/i`%/�/%/\\�\/�\Y/ /i/%/ \\\\\�\\\� /.\\/n\n\\\\/\y/ /�\��// /\y POND BOTTOM ANTIO�FLOATATION / /\�//\\//T\/\y/ /<�C\\!� y�\\% ANTI-SEEI •.•�....^.,^�^v,��'. / \Y / / /\ /� ELEV: 33.00' COLLARS U' SPILLWAY ELEV: 39.25' ROAD 'A' AR �--- 170' 10.0' APPROX. 450/✓Y FOREBAY VEGETATED BOTTOM SHELF POND-1 PATH OF FLOW CROSS-SECTION NOT TO SCALE SEDIMENT FOREBAY WEIR MAIN POND POND EMBANKMENT 10.0' EMERGENCY SPILLWAY RISER TOP OF BERM SPILLWAY ELEV: FG: 28.00' ELEV: 31.00' ELEV: 34.00' 32.50' REVERSE -SLOPED 2.0" TOP OF BERM ORIFICE ELEV: 30.00' TEMP. POOL ELEV: 31.0' TEMP. POOL ELEV: 31.0' 36- HDPE 36' HDPE NORMAL WATER LEVEL: 30.00' FG: 27.00' SPILLWAY PIPE SPILLWAY PIPE 3'l 3'1 `3.1///\\/,\(/\FOREAY WEIR\//\/\// //�.10:1\ PERMANENT POOL 3:,/�\y/ n \ \�\\ �\ \ \ p) I RAP APRON / y/�x/�\\y/\y/� ELEVS2\8'00' y/\Y/�\ �\�!/�\�//vim//\,� / CONCRETE \//\yT%ANTI-SEEP / // FOREBAY BOTTOM \// / / / \/ \�\\//\�\%�\Y///V\/\Y\�\�\j%/�% . ANTI-FLOATA110N�j '%� COLLARS \✓//\\Y/!�`\\//\/\`\</\\��%\\// % ELEV: 25.00' "/ //\//.\//�i'C�\\7T\��/?j'\\J.. 'C\\�\/\\�\\�\\ j% a�\ �/�\\iPOND BOTTOMS\\\/ //\\�\�\\E COLLAR \\ ;C\\�\;C\\ ELEV:'25.00'.j�Yl.\ z 95' 10.0' APPROX. 290' FOREBAY VEGETATED BOTTOM SHELF POND-2 PATH OF FLOW CROSS-SECTION NOT TO SCALE SEDIMENT FORE13AY WEIR MAIN POND POND EMBANKMENT 10.0' EMERGENCY SPILLWAY RISER TOP OF BERM SPILLWAY ELEV: FG: 20.00' ELEV: 23.35' ELEV: 24.75' 24.00' REVERSE -SLOPED 2.0' ORIFICE TEMP. POOL ELEV: 23.35' TOP OF BERM ELEV: 21.00' TEMP, POOL ELEV:ELEV: 22.00' 23.35' - •-• --- NORMAL WATER LEVEL: 22.00 FG: 19.00' NORMAL WATER LEVICE-777= 3.1 PRAP APRON C 3:1 \� jY WEIR \\/�/�\/�, E EVBA20. 0' �YWFIR�\j/\\%// /\y/\\it0:1 PERMANENT POOL /3. n\ \ \//\ POND BOTTOMY�\�,\\/,\\/\ /\/\\\j-\� ANTI COLLAR T �/j\/\/\//\/// //\\/ / ELEV: 17.00'..\ /\.<\ \ \//.� /%/%` /i> /i�/i�•/i\/a /,✓,(\/ \z Z>/,tC\/C\\_ELEV: 17.00'.;tC\'<C\'<C\ 35' 10.0' APPROX. 110' FOREBAY VEGETATED BOTTOM SHELF POND-3 PATH OF FLOW CROSS-SECTION NOT TO SCALE -tom- - - _ FOREBAY BOTTOM 32.00' MSL 171' o c, 60' \0 MAIN POND BOTTOM 32.00' MSL P40ND-1 PLAN SCALE: 1" = 50' fr/4 /f5/646 io' PRELIMINARY DESIGN NOT RELEASED FOR CONSTRUCTION /4 \ 187 f 92' FOREBAY BOTTOM 25.00' MSL 116' --.. of 1011 VEGETATED SLOPE 000, FOREBAY WEIR 85' MAIN POND BOTTOM 25.00' MSL 270' 10:1 POND-2 PLAN SCALE: 1" = 50' RIPRAP APRON 1DPE (2) 30' HDPE PIPE SPILLWAY PIPE 3.1 RIPRAP APRON \ \ \// ANTI-SEEP(�\/ /,(\/,(\/,< ,(\/iC\•C\ \ \�\ ,\// COLLARS APRON 4' CONCRETE SQUARE RISER WITH TRASH RACK TEMP. STORAGE ELEV: 38.50' ELEV: 38.50' TEMP. STORAGE ELEV: 38.50' PERMANENT POOL ELEV: 38.06 PERMANENT POOL ELEV: 38.00' 2.0" REVERSE SLOPED ORIFICE t. • WITH SCREEN < ELEV: 38.00' USE ELASTOMETRIC BOOT AND ';- SEAL WITH NON -SHRINKING GROUT ON BLEEDDOWN AND s. PRINCIPAL SPILLWAY ORIFICES 24" CPP SPILLWAY BARREL INV. IN: 34.00' T•�� _ - _ . ■• 1 1 1 1•• 1• 1 1 1 1•• �%/\\�/�\//Q!/Q//\\//\\i/Q//Q//Qi/Q//�\i/Q Will twiltlialmWIM0 GROUT ON BLEEDDOWN AND PRINCIPAL SPILLWAY ORIFICES (7' BASE. V THICK) POND-2 RISER WITH ORIFICE DETAIL NOT TO SCALE 5' CONCRETE SQUARE RISER WITH TRASH RACK TEMP. STORAGE ELEV: 23.35' ELEV: 23.35' PERMANENT POOL ELEV: 2 .00' 12.0" REVERSE SLOPED ORIFICE WITH SCREEN USE ELASTOMETRIC BOOT AND �s• ELEV: 22.00' SEAL WITH NON -SHRINKING ;? GROUT ON BLEEEDDOWN AND PRINCIPAL SPILLWAY ORIFICES i (2) 30" CPP SPILLWAY BARRELS INV. IN: 21.50' "'A'/N! ANTI -FLOATATION COLLAR'�,�­ (7' BASE. V THICK) P43ND-3 RISER WITH ORIFICE DETAIL 31, 81' 33' j MAIN POND BOTTOM FOREBAY 17.00' MSL Rr��\WEIR \\\ FOREBAY BOTTOM Q \ \ 17.00' MSL r POND-3 PLAN SCALE: 1" = 50' `Vw lbil 54' 18'i AMENITY AREA PLAN SCALE: 1" = 40' i� m IIIUI LEGEND: APPROXIMATE WETLAND LOCATION - - - - EXIST. MAJOR CONTOUR EXIST. MINOR CONTOUR - 4191-L1Dl - EXIST. PROPERTY BOUNDARY 38 PRO. CONTOUR - - -- PRO. LOT LINE PRO. EDGE OF PAVEMENT PRO, BACK OF CURB ------- PRO. ROAD CENTERLINE - - '-"-' - - PRO. RIGHT OF WAY - - - - - - - - - - PRO. EASEMENTS PRO. STORMWATER LINE PRO. SIDEWALK PRO. DRAINAGE BASINS PRO. HIGH / LOW POINTS ��- PRO. FLOW DIRECTION c"I PRO. DRAINAGE BASINS BUILT UPON CALCULATIONS OVERALL AREA: TOTAL PROJECT AREA = 42.41 AC. DEDUCTED WETLAND = -0- TOTAL USABLE AREA = 42.41 AC. IMPERVIOUS AREA: RESIDENTIAL BUILDINGS = 10.59 AC. STREETS AND ROADWAY = 3.25 AC. EXTRA PARKING = 1.52 AC. SIDEWALK = 0.58 AC. AMENITY CENTER = 0.04 AC. TOTAL = 15.97 AC. PROJECT DENSITIES: 15.97 AC. 42.41 AC. (100) = 37.7 % REV. - S 0 RC 3 STORMWATER COMMENTS 04/13/06 REV. NCDENR-DWQ: SW8 051045 JRC 2 STORMWATER COMMENTS 03/08/06 REV. NCDENR-DWQ: SW8 051045 JRC 1 STORMWATER COMMENTS 02/14/06 REV. DESCRIPTION Y DA� REVISIONS OWNER: PALMETTO CREEK, L.L.C. 6740 NETHERLANDS DRIVE, SUITE WILMINGTON, NC 28405 (910) 452 - 7175 (910) 452 - 2135 (FAX) Coastal ]Land design, PLLC Civil Engineering / Landscape Atchitectum / Construction Management P.O.Box 1172 Phone:910-254-9333 Wilmington, NC 28402 Fax: 910-25"502 10 DRAWN : J. CARMINE PROJECT NUMBER 150-01 DESIGN J. CARMINE CHECK : J. PETROFF SCALE : NOT TO SCALE APPROVED : J. PETROFF DATE : 31-JAN-2006 FILE NAME : THE RESERVE AT PALMETTO CREEK STORMWATER SYSTEM CONSTRUCTION DETAILS JOB NUMBER SHEET NUMBER 150-01 SW- 4 j!1