Loading...
HomeMy WebLinkAboutNC0063321_Authorization to Construct_19981009NPDES DOCIMENT SCANNING COVER SHEET NC0063321 Cashiers WWTP #3 NPDES Permit: Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) Permit Modification Complete File - Historical Engineering Alternatives (EAA) Correspondence Owner Name Change Meeting Notes Instream Assessment (67b) Speculative Limits Environmental Assessment (EA) Document Date: October 9, 1998 Thies document is printed on reuse paper. - igiuore :my content on the reirerese side rs State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary A. Preston Howard, Jr., P.E., Director Mr. Jerry R. King Executive Director Tuckaseigee Water & Sewer Authority Post Office Box 1051 Sylva, North Carolina 28779 October 9, 1998 e�� DENR Subject: Permit No. NC0063321 Authorization to Construct ATC No. 063321ACC Cashiers WWTP Jackson County Dear Mr. King: On August 20, 1998, the Division of Water Quality received your request for Authorization to Construct (ATC) in accordance with NPDES Permit Number NC0063321. The plans and specifications for adding a standby generator capable of powering the Cashiers WWTP and for building an enclosure to house the existing blowers have been reviewed and it was determined that they are satisfactory. Authorization is hereby granted for the installation of a standby generator and an enclosure to house the existing blowers. The enclosed copy of the approved plans and specifications must be maintained on file for the life of the facility. This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NC0063321 issued April 21, 1998, and shall be subject to revocation unless the proposed residuals storage tank is constructed in accordance with the conditions and limitations specified in Permit No. NC0063321. Please be advised of the deadlines associated with the special conditions included in permit NC0063321 issued on April 21, 1998: • Automatic Standby Power Requirement It is a requirement of Title 15A of the North Carolina Administrative Code, Subpart 2H.0219 (j) (3)(A) that dual source/dual feed or automatically activated standby power capable of powering all essential treatment components under design conditions is required for all treatment works. The Permittee is required to install an automatic backup power system within 90 days of the effective date of the permit. P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-0719 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper Permit No. NC0063321 Cashiers WWTP Page 2 of 4 • Noise Reduction Requirement The Permittee is required to prepare and submit a proposed design of an enclosed structure for the blowers or other noise reduction equipment within three (3) months of the effective date of the permit and final installation within six (6) months. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Asheville Regional Office, telephone number (828) 251-6208, shall be notified at least forty- eight (48) hours in advance of operation of the installed facilities so that an in -place inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion and prior to the operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit. Mail the Certification to the following address: Department of Environment and Natural Resources Division of Water Quality NPDES Unit, 9th Floor Post Office Box 29535 Raleigh, North Carolina 27626-0535 The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and is a condition of this Permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by G. S. 143-215.6 for violation of or failure to act in accordance with the terms and conditions of this Permit. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division of Water Quality in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. In closing, I would like to state that it is the Division's ultimate goal to provide quality service to the public.' Please take a moment to review the procedures you followed in applying for this Authorization to Construct in addition to the Division's response to your project needs. If we can improve our service to you in any manner, please bring it to our attention. We appreciate your cooperation during the review process and we look forward to working with you in the future. Permit No. NC0063321 Cashiers WWTP Page 3 of 4 If we can be of further assistance to you or if you would like to suggest any improvements we can make to strengthen our customer service efforts, please do not hesitate to contact Jeff Myhra of my staff at (919) 733-5083, extension 597. Preston Howard, Jr. cc: Central Files NPDES Unit, Permit File Asheville Regional Office, Bill Anderson Technical Assistance and Certification Unit Ms. Jane Gorsline P.O. Box 272 Cashiers, NC 28717 Mr. John Druffus Brookings P.O. Box 1069 Cashiers, NC 28717 e Permit No. NC0063321 Cashiers WWTP Page 4 of 4 Engineer's Certification I, , as a duly registered Professional Engineer in the State of North Carolina, was authorized to observe (periodically, weekly, full time) the construction of the for the Permittee. Project Name Location I hereby state that, to the best of my abilities, due care and diligence was used in the observation of construction at the Cashiers Wastewater Treatment Plant. Installation of the standby generator and the enclosure for the blowers was observed to be within substantial compliance and intent of the approved plans and specifications: Signature: Registration No. Date: t J. Wayne Craig Stewart W. Hubbell Sam H. McGhee. III Gene R. Cress Edwin K. Mattern. Jr. 1949-1982 Mr. Jeffrey T. Myhra Environmental Engineer NCDENR P.O. Box 29535 Raleigh, NC 27626-0535 SINCE Mattern & Craig 1978 CONSULTING ENGINEERS • SURVEYORS September 16, 1998 Re: Cashiers WWTP Permit No. NC0063321 Comm. No. 1457P Dear Mr. Myhra: The following are our responses to your comments of February 5, 1998: 1) See Sheet 3 as revised. 2) See Sheet 8 for details of chlorination/dechlorination. 3) Baffle (Sect. 8.3) and serpentine design will prevent short circuiting in the tarilc'- 4 ,:.Underflow baffle in Section 8.1 will prevent. SO2om enteringcontact tank. ; . P z ,�r4"t Wm. James Jones Michael S. Agee Steven A Campbell Kyle D. Austin Randy W. Beckner 5) CL2 is added to system in manhole adjacent to CL2/SO2 chamber. The requirement of 2H.0219(j)(6) is for "seasonal or resort facilities". This treatment facility is for the entire Town of Cashiers and the surrounding area. It does not serve a "facility". Furthermore, the design flow is for the highest expected "seasonal" flow with a peak factorof 2.5. 429 Clay Street, Kingsport, Tennessee 37660 (423) 245-4970 Fax (423) 245-5932 Mr. Jeffrey T. Myhra September 21, 1998 Page 2 7) See Sheet 3 as revised and Sheet 4 as submitted. 8) These are existing units. 9) This unit is a single tank with reinforcing brace. Tank is field welded together. 10) Overflow from the backwash tank and the backwash holding tank goes into the CL2 manhole, not on the ground. 11) This design is identical to existing. There is no mixing in the existing tank and no operational problem. 12) A hand -off -auto (HOA) switch is provided for each pump. Piping arrangement (See Sheet 7) allows for manual by-pass. 13) See Sheet 8 as revised. 14) See Sheet 7 as revised. 15) See Sheet 9 as revised. 16) The pump is a rotary positive displacement. Therefore, backflow is impossible. The line is routed such as to avoid freezing. 17) See Sheets 9, 10 & 11 as revised. 18) See Sheets 4 & 14 as revised. 19) See Sheet 4 as revised. 20) Specified CL2 and SO2 injectors require a minimum supply pressure of 25 psi. This is being verified and will be supplied to you shortly. - sy. 21) The plans as submitted contained a new emergency generator capable of runni g the ` entire plant. However, this unit is now shown`as existing as the Owner is currently pursuing the installatiori of the generator. 22) The hydraulic grade calculations are included in the enclosed design calculations. Mr. Jeffrey T. Myhra September 21, 1998 Page 3 23) 30,000 gallons of residual storage is provided which meets the requirement of 2H.0219(j)(9). Also, enclosed, please find a $200 check for the review fee. If you have any questions, please feel free to call. Sincerely, MATTERN & CRAIG, INC. 4J• za„, Randy W. Beckner, P.E. Principal RWB/alf