Loading...
HomeMy WebLinkAbout20070018 Ver 2_General Correspondence_20070917August 31, 2007 Mr. Gary Lynch 42 East, LLC PO Box 20012 Raleigh, NC 27619 ~~~Qb ~~ SEP 1 7 2007 DENR - Wgp~ER 411 W A~tD SPO~@'~AI~iN RANCH Re: 42 East Development Main Entrance Road and Sections I & J Stormwater Management Statement and Plan Dear Mr. Lynch: We have reviewed the revised Stormwater Management Plans and Calculations submitted for the proposed 42 East Development Main Entrance Road and Sections I & J. Based upon the information submitted, the stormwater management plan has been approved with the following stipulations: Please. address the following with respect to the Total Nitrogen calculations: a. The calculations indicate a 25% nitrogen reduction for Bioretention Area/Pond #5. However, the NC DWQ BMP Manual allows a 35% credit for bioretention nitrogen reduction. Please revise the nitrogen export calculations as appropriate. b. Please provide an offset payment in an amount to be determined to the "North Carolina Ecosystem Enhancement Fund" (formerly known as the Wetland Restoration Fund) to buy down Nitrogen export. The payment and a copy of the final stormwater management plan approval letter should be sent to the attention of Kelly Williams at the following address: NC DENR EEP 1652 Mail Service Center Raleigh, NC 27699-1652 Please address the following comments with respect to the attenuation analysis (Pond #1, Pond #2, Pond #3, Pond #4, and Pond #5): a. Please provide pre-development calculations for the 1, 10, 25, and 100 year storm events, as the design drainage area has been modified from the previously submitted calculations. b. Provide a detailed profile sheet with elevations for Pond # 1 and Pond #2. c. Provide the proposed landscaping plans. d. Provide label the level spreader at the outlet for Pond #3. e. Please provide recorded drainage and access easements to and around each pond. f. Please provide recorded Inspection and Maintenance Agreements for each device. Draft copies of the Inspection and Maintenance Agreements should be provided prior to recordation. Please provide a 5' drainage easement on all interior lot lines as part of the final plat to address any future cross lot run-off . Page 2 August 31, 2007 Mr. Lynch 4. Please be advised that the proposed storm sewer system located within the future NCDOT ROW has not been reviewed. It is the responsibility of the design engineer and the developer to verify that the system has been designed adequately. 5. The 30.56 acres proposed for land dedication must be recorded in a permanent conservation easement in order to comply with Johnston County's Land Dedication requirement. 6. Future sections of the development must comply with the fill areas shown in the 20% fill calculations for the onsite floodplain areas as currently submitted. Any changes to the areas of fill in the future development will require the overall development readdress the floodplain fill calculations. 7. Please provide copies of all 401/404 permits required for the proposed development once received. 8. Please provide a copy of the recorded restrictive covenants (for each section, as applicable) and a note on each Final Plat limiting the impervious area on each of the 177 lots in Section I to 2,681 square feet and the each of the 106 Lots in Section J to 2,810 square feet. 9. Please provide a copy of the recorded restrictive covenants noting who will be responsible for maintenance of all drainage facilities located outside of the proposed NCDOT right of way. 10. Please provide a note on the Final Plat indicating that all lots located within the 100-year Fooodplain must adhere to the Johnston County Flood Damage Prevention Ordinance. 11. Prior to recordation of the Final Plat, please provide a stormwater certification stating that all stormwater facilities were constructed in accordance with the approved stormwater management plan. 12. Please indicate all drainage easements, riparian buffers, jurisdictional wetlands, and flood hazard areas on the Final Plat. Please be reminded that a detailed stormwater management plan must be approved for each subsequent phase of the proposed development, including the proposed commercial areas site plans. This approval is valid for the Main Entrance Road, Section I, and Section J only. A copy of this letter will be forwarded to the Planning Office for their files. If you have any questions or need additional information, please contact me at (919) 209-8333 or by email at chandra.coats@j ohnstonnc.com. Sincerely, Chandra C. Coats, PE Utilties and Environmental Engineer cc: Berry Gray, Planner Kirk Rightmyer, PE