Loading...
HomeMy WebLinkAboutNCG551792_Application_20220824 f t ROY COOPER Governor dG ELIZABETH S.BISER 4.94. /M Secretary - RICHARD E.ROGERS,JR. NORTH CAROLINA Director Environmental Quality August 25, 2022 Richard Beck 2656 Findlay Ave Palm Bay, FL 32908 Subject: Permit Application Application No. NCG551792 2656 Findlay Ave Clay County Dear Applicant: The Water Quality Permitting Section acknowledges receipt of your application for a new NPDES WW permit, including supporting documentation and your check number 4164 in the amount of$60.00 as payment of the application fee.These items were received in our offices on August 24, 2022. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. The permit writer will contact.you if additional information is required to complete evaluation of your application. Your timely and direct response to any such request will help to expedite the review process. Please note that acceptance of the application does not guarantee a NPDES permit will be issued for the proposed activity. A permit will only be issued following a complete review of the application, concluding the proposed discharge is allowable per applicable statutes and rules. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deq.nc.gov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sincerely, .3CParCISIC\ Wren Thedford Administrative Assistant Water Quality Permitting Section cc: Michael Lash, PE.-Lash Engineering ec: WQPS Laserfiche File w/application -DE Q l North of m Qali I Dif W vAsheville RegionalCarolinaDepartment Office 12090 US.Environ Highwayental 70u I ty Swannanoa.ivison No CarolaterinaResourc 28es78 7 +r,�•�.o_.ee� 828.2964500 TRANSMITTAL Date: August 19, 2022 LASH ENGINEERING Attention of: John Hennessey Consulting Engineers Civil,Planning,Wastewater Company: NPDES-DWR 1104 Cindy Carr Drive Matthews,NC 28105 From: Michael Lash, PE. Phone: 704-847-3031 mikelajashenqineering.com Project: Beck - Direct Discharge Wastewater Application Special Instructions: Please find enclosed is the initial submittal package for a Direct Discharge Permit for the Beck Residence: RECEIVED 1. 1 set of plans 2. 1 sets of the submittal package in bound form. -•; ; 2 4 2022 3. 1 copy of the Letter of Authorization, 4. 2 copies of the Request for the Permit NCDEQ/DWR/NPDES 5. 2 copies of the signed Application form. 6. The bound package have these forms as well. 7. A check for $60.00 is paper clipped to this transmittal. Thank you. If you have any questions, please call me at: 704-847-3031. Thanks ichael Lash, PE. '� r Beck Direct Discharge Wastewater Facility National Pollutant Discharge Elimination System FOR AGENCY USE ONLY (NPDES) Division of Water Resources Date Received Application for SURFACE DISCHARGE Year Month Day Environmental Certificate of Coverage(COC)Under a V O D S a y Quality General Permit NCG550000 Certificate of Coverage(COC) For Single-Family Residences and Similar Discharges N C G 5 5 1 1 9 a 100%-domestic wastewater-<1,000 gallons per day Check# Amount This existing 8-bedroom house was constructed in 2005. Unfortunately it was permited as a 3-bedroom and the disposal system was installed as a 3-bedroom. C20 0� Current Owner is renovating the house and needs all 8-bedrooms. The Health Assigned to: Department cannot find enough available land for the full 8-bedrooms. The Health Department recommended this NCG550000 Direct Discharge permit. The Division of Water Resources will not accept an application package unless all instructions are followed. Failure to submit all required items may result in the application being returned. For more information, visit the Water Quality Permitting Section's NPDES Permitting Unit website. (Press TAB to navigate form) 1. Regional Office Contact: Please contact your DWR Regional Office before submitting this application. If you have not met with your appropriate DWR Regional Office Representative,the application will be returned. - Please list the DWR Regional Office representative(s)with whom you have discussed this project: Name(s): Mikal Wilmer Asheville Regional Office Office: 828-296-4686 Cell: 82 �,9��ift�5.'��D Mikal.Wilmer@NCDENR.GOV Date: Date not available. tt ���� 2 4 2022 2. Owner's Contact Information: Applicant Type: ® Individual ❑Corporation ❑Partnership NCDEQIDWR/NPDES Owner Name and Title: Richard Beck Street Address: 2656 Findlay Avenue FL- City: Palm Bay State: 14G, Zip:32908- Telephone#(1-1): 585-746-1515 Telephone#(W): Cell/Mobile#: 585-746-1515 Email:info@mitchellcountyanimalrescue.org 3. Location of Facility Producing the Discharge: Please list the address of the facility.If facility is not yet constructed,give street address or lot number. Street Address: 51 Compass Creek Drive • City: Hayesville State: NC Zip: 28904- County: Clay Telephone#: 585-746-1515 Cell/Mobile#: Website: There is no website for this facility 4. Site-Location Narrative: Please describe how to get to the facility from the nearest town,major highway or identifiable roadway intersection(use street names,state road numbers,and/or distances and directions). Heading East on Tusquittee Road, continue past Taxi Drive, Cold Branch Road,and Compass Meadows Drive until you reach Compass Creek Drive. Take a left onto Compass Creek Drive, and the site will be on your left. Page 1 of 6 Revised:A. Orlando NPDES 21 Sept2017 Application for Certificate of Coverage(COC) and/or Authorization to Construct(ATC) under General-Permit NCG550000 5. Describe the nature of the project. ["New"means has not yet been physically constructed,"existing" means system already physically exists.Please see 15A NCAC 02H.0103(11) for further clarification]. ❑ Installation of a New Wastewater Treatment System(If yes, skip to Number 9.) ❑ Expansion of an Existing Wastewater Treatment System(for example,adding bedrooms)(If yes, skip to Number 9.) • Replacement of an Existing Wastewater Treatment System(If yes,go to Number 6.) 6. Describe the Existing Wastewater Treatment System: ❑ Conventional Septic Tank/Leach-field—Discharge to Sub-Surface Soils.If previously permitted, please attach a copy of the permit or enter the permit number Permit issued 2-24-1982. If you are not aware of an existing permit,check here. ® included in submittal book ❑ Sandfilter—Discharge to Surface Waters [or other,as defined 15A NCAC 02H.0103(11)].If previously permitted,please attach a copy of the permit or enter the permit number If you are not aware of an existing permit,check hem. ❑ ❑ Filter Media System(Pod System)—Discharge to Surface Waters [or other,as defined 15A NCAC 0211.0103(11)J. If previously permitted, please attach a copy of the permit or the permit number.If you are not aware of an existing permit,cheere. ❑ Other ❑ Check here if submitting proposal for a new system or if no treatment system exists. 7. Check all EXISTING wastewater treatment components: ®Septic tank ❑Dosing tank ❑ UV disinfection ❑Primary sand filter ❑ Secondary sand filter ❑ Recirculating sand filter(s) ❑Chlorination ❑Dechlorination ❑ Other components: ❑ Self-Contained POD system [describe] ®Leach Field ❑Post Aeration (sped type) 8. Provide Details of Single-Family Residence(SFR)or Similar Facility: a) Type of facility: ®Residential ❑Commercial ❑Other: b) Amount of wastewater discharged: Existing house has 8-bedrooms. - Residential:Number of bedrooms 8 x 120 gallons per bedroom= 960 gallons per day(flow) - Commercial: How many employees?(25 gpd/person) Page 2 of 6 Revised:A. Orlando NPDES 21 Sept2017 Application for Certificate of Coverage(COC) and/or Authorization to Construct(ATC) under General-Permit NCG550000 c) Is your existing treatment system failing? Yes ® No ❑ d) Has the Health Department formally condemned your existing system "unsuitable for repair?" Yes ® No ❑ If yes,please name the Health Department[local,county,or state],and provide the site- inspection date [attach Health Department's judgement letter, if available]: Clav County Health Department 10/28/2021 Denial Letter is included in submittal book. If previously permitted[local,county,or state],provide permit number and date issued [attach copy, if available]: Not Available 9. Check all PROPOSED new system components ❑ Septic tank ❑Dosing tank ® UV disinfection: ❑Primary sand filter ❑ Secondary sand filter ❑ Recirculating sand filter(s) ❑Chlorination ❑Dechlorination ® Other components: AquaSafe PreTreat Unit ❑ Self-Contained POD system [describe] ❑Post Aeration(specify type) ❑ Proposed Modifications to Existing Treatment System-Explain in detail the nature of the modification. Attach all site maps,plans and specifications,signed by an NC Certified Engineer. If prepared by others,plans must conform to 15A NCAC 02H.0139. Only the existing septic tank will be used. The rest of the system is proposed. Proposed New Treatment System for Surface Discharge(not constructed)-Attach all site maps, plans and specifications,to be signed by an NC Certified Engineer. If prepared by others,plans must conform to 15A NCAC 02H.0139. The existing 800g precast tank will be used behind a new 1,000g septic bank that will gravity feed to a pretreat tank with an UV • light.Plans are attached and also part of the Submittal Book Expanding Flow?-Do you propose to increase permitted or existing flow? {]Yes ❑ No Provide details of the Proposed NEW Discharge[Flow and Source Water]: Technically the answer is yes but only because it wasn't permitted for 8- ® Check if same as 6. bedrooms originally. The existing house is not being expanded from its original construction. Existing:Amount of wastewater currently discharged: Number of bedrooms 8 x 120 gallons per bedroom= 960 gallons per day to be permitted(design flow) Expanding: Amount of wastewater proposed to be discharged:Number of bedrooms 8 x 120 gallons per bedroom= 960 gallons per day to be permitted(design flow 10. Evaluate Alternatives to Discharge to Waters of the State.Please address the feasibility of discharge alternatives as instructed in the NCDEQ Engineering Alternatives Analysis(EAA) Guidance Document found here. (Note:Evaluation for endangered species is not required.) There is an EAA Section in the submittal book with all of these reports. a) Connection to an Existing Wastewater Treatment System-Provide the distance to the nearest connection,such as a regional or municipal sewer system,and the Page 3 of 6 Revised:A. Orlando NPDES 21Sept2017 Application for Certificate of Coverage (COC) and/or Authorization to Construct(ATC) under General-Permit NCG550000 estimated cost per foot to connect including fees. This is part of submittal package. b) Land Application—Assess the land application disposal alternatives such as spray irrigation,drip irrigation, individuaUcommunity onsite subsurface systems, and/or innovative ground-absorption. Questions to consider: This is part of the EAA submittal package. (1) Are on-site soils suitable for land application? Yes ❑ No (2) Is there sufficient area on-site? Yes ❑ No 1 c) Wastewater Reuse—Evaluate reusing all or a portion of the wastewater generated, such as for golf course irrigation, crop irrigation(e.g.,hardwood or pine plantation, grasses), athletic field irrigation, landscape uses, and/or commercial/industrial uses. This is part of the EAA submittal package. d) On-Site Soil Evaluation—Submit an evaluation of the soils on-site, documented by a certified report from a NC Professional Soil Scientist, or by your local or county health department report(if available). The Local Health Department made an evaluation and is part of their"Denial Letter". e) Cost of Alternatives—Provide an estimation of the cost of each discharge alternative or combination of alternatives.Included in submittal package along with b-d. This is part of each report and the summary sheet. 11. Provide Regional Information: Ple ase ease provide the following information. If you need assistance in obtaining this information,please contact your local DEQ regional office. a) Stream Classification-Verify the stream classification for the nearest downgradient named waterbody. The NC Surface Water Classification map can be found by clicking here. Classification: C;Tr b) Is it a High-Quality Water?If so, check if it is by definition or by designation?In order to check this,ask the Planning Unit. No. c) Map-Provide a map locating the nearest downstream waters-of-the-State(i.e. where the effluent reaches an unnamed tributary,creek, stream,river,or lake via any surface-water conveyance). Part of Submittal Package A section of the Submittal Book has this information. d) Site Evaluation -Contact DEQ's local Regional Office for a site evaluation to confirm the proposed discharge flow path to the nearest waters-of-the-State. The wastewater/stream confluence and stream class must be verified in the field by DEQ's Regional Staff. Please list the Regional Office staff member you contacted for the inspection. A package was mailed. Mikal Wilmer Cell: 828-989-9695 Office: 828-296-4686 Mikal.Wilmer@NCDENR.GOV e) Flow Path-Display graphically the flow path of the discharge to the nearest surface Waters of the State. Document any potential hydrologic trespass or right-of-way infringement on any neighboring property(i.e. note all properties encountered prior to reaching waters-of-the-State). Part of Submittal Package A Site Plan created on a boundary survey shows that the creek is on this property and is part of the plans included with this submittal. Page 4 of 6 Revised:A. Orlando NPDES 21Sept2017 Application for Certificate of Coverage (COC) and/or Authorization to Construct(ATC) under General-Permit NCG550000 f) 7Q10/30Q2 Estimate-Contact USGS J. Curtis Weaver(919-571-4043)to provide the estimated 7Q10 and 30Q2 stream-flow estimates for the first downstream point-of-contact with waters- of-the-State. The Project has been accepted for review but has not been completed. The report will be forwarded when received. 11. Certificates of Coverage/Notices of Intent to Discharge/Authorizations to Construct-Check ALL of the following information has been provided. Incomplete Applications will be returned. ® An original letter[two(2)copies] requesting coverage under NCG550000. ® This application [two(2)copies].Your signature on this application,certifies that you are legally responsible for the proposed treatment system(see page 6 of 6)for the COC/NOI/ATC. ® A check or money order for$60.00 permit fee made payable to NCDEQ. 12. Additional Application Requirements a) Narrative Description of the treatment system.This narrative should present treatment components in order of flow—influent to outfall, including anti-erosion structures and sample-port location(s). An Engineers Summary Report is included in the application along with a Maintenance Form. b) Final Plans and Specifications for a wastewater treatment system shall be signed by a North Carolina-registered Professional Engineer, or if prepared by others,must conform to I 5A NCAC 02H .0139. All_documents are to be stamped "Final Design-Not Released for Construction." Submittal shall include a site map showing the proposed outfall and the effluent proposed path to surface waters-of-the-State.(see Item 1 for location verification by DWR Regional Office staff) c) Submittals by a Consulting Engineer or Engineering Firm shall include: 1. A copy of your written authorization to represent, signed by the legal permit Applicant; and Included in Submittal. 2. Upon completion of proposed work,a signed copy of DWRs Engineer's Certification form attesting that the project was completed in accord with the DWR approved COC/ATC,as issued. This will be completed when it is appropriate. ******************************************************************************* CERTIFICATION I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true,complete, and accurate. Printed Name of Person Signing: ?1 c/IA(j j�G G 1 Title: 1-g6 5i.„ eI , ✓m ✓�ifr-c, (Please review 15A NCAC 02H.0106(e)for defmition of authorized signing officials) t a- 919/Z — Click here to enter a date. (Signature of Applicant) (Date Signed) Page 5 of 6 Revised:A. Orlando NPDES 21Sept2017 • Application for Certificate of Coverage (COC) and/or Authorization to Construct(ATC) under General-Permit NCG550000 NOTE: Treatment System Maintenance is Required -Upon receiving a Certificate of Coverage/Authorization to Construct(COC/ATC),the Division recommends that the Permittee solicit manufacturer-certified training,or solicit a qualified contractor or service to regularly inspect and maintain this treatment system. The Permittee is responsible under this COC/ATC to maintain all components of the approved treatment system,designed to meet Surface Water Quality Standards [see attached Operation and Maintenance Agreement]. Compliance duties include: • paying your annual fee [due on the anniversary of COC/ATC effective date], • following the manufacturer's guidelines, • conducting and documenting inspections, in compliance with General Permit NCG550000, • establishing sources for OEM spare parts and supplies, • taking discharge samples for analysis,and logging the results, • making necessary repairs, documenting said maintenance in logs,and • keeping logs onsite for the life of the permit,available for DWR inspection. North Carolina General Statute& 143-215.6B provides that: Anyperson who knowingly makes anyfalse statement representation,or certification in any application,record, gY report,plan,or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the Commission implementing this Article,shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars($10,000). 18 U.S.C. Section 1001 provides a punishment by a fine or imprisonment not more than 5 years,or both,for a similar offense. Application must be accompanied by a check or money order for$60.00 made payable to: NCDEQ • • • • • Mail this application and one copy of the entire package (with check) to: NCDEQ/DWR/NPDES Attention: John Hennessy, Supervisor Compliance and Expedited Permitting Unit 1617 Mail Service Center Raleigh,North Carolina 27699-1617 Attn: John Hennessy Note: Submission of this document insures DWR's consideration, but does not guarantee issuance of a Certificate of Coverage/Authorization e/Authorization to Construct.g Page 6 of 6 Revised:A. Orlando NPDES 21 Sept2017 I CUENT: Richard Beck N -p�, c) 2656 Findlay Avenue mo •o - NI Palm Bay, Fl. 32908 o o 7USQU/TIES RD 0-. Contact Person: . o (585) 746-1515 6 rbeck001 @rochester.rr.com __ _--) 2 COLD SPRING LN Date: 5-12-22 Scale: 1' =50' VICINITY MAP not to scale PROPERTY LINE .41001, DI Not a AQUASAFE A s UNIT y'fS��"p'q�,j F; ' "` Direct Discharge Wastewater Faclitty for: s ,t a,- Richard Beck 51 Compass Creek Dr. `& a Hayesville,NC. 28904 y . ill . __ N N 1072.W " 1• o , _`, 21.54' 1.oet.C1� I '" / I,1& A W CREEK 4. aK. xac.ix, / W z' / „ HOUSE TBAC . land SETBACK C-. 4 \ 3 1/1I ,��i' `f \ ‘4,0Idr ��' � LASH N ' J K g j I n...., ENGINEERING / '" 1 j Consulting CM!Engineer/Planner 0 1104 Cindy Cam Drive I ,- 4 Matthews,N.C. 28105 $2 4M, Phone:704/847-3031 g w email:mikeIO m laehenginee 1ng.co a `ry License#C-2433 0 BRAND BK.444 Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews,NC 28105 Phone: 704-847-3031 mikeqLashEngineering.com Lash Engineering, Inc. TABLE OF CONTENTS (for all submittal) General Submittal Information 1. Cover Sheet 2. Table of Contents 3. Beck—Owner Authorization Letter 4. Beck- Request Permit Letter 5. Engineer's Project Summary 6. Health Department Site Report(Denial) 7. Health Department (original permit) 8. NC.DWR—Permit Application General Permit 9. Copy of Check for Permit($60.00) 10. Lash Engineering as Authorized Designer(AquaSafe) EAA/EPA 11. Table of Contents 12. EAA Summary 13. EAA Alternative"A" Public Sewer Availability a. Email from Clay County b. Alternative"A" Public Sewer Evaluation 14. EAA Alternative"B" Land Application Option a. Alternative"B" Subsurface Evaluation b. Subsurface Sketch c. Alternative"B" Surface Evaluation 15. EAA Alternative"C"Wastewater Reuse Evaluation 16. Health Department Evaluation 17. EAA Alternative"D" Direct Discharge 18. EAA Summary Alternatives Report 19. NPDES Form 1 20. NPDES EPA Form 2a Watershed &Additional Information 1. Table of Contents 2. NC Surface Water Classification Report 3. NC Residential StreamStats Report with Watershed 4. Full FIRM Floodway Map 5. USGS Map NC Shooting Creek 6. Results of USGS Low Flow analysis General Page 2 7. Endangered Species Report 8. Endangered Species Report Fee Operation & Maintenance 1. Table of Contents 2. Operator Checklist—Engineer Supplied for Direct Discharge 3. AquaSafe Brochure 4. AquaSafe Septic &Aerobic 5. AquaSafe Cut-Away 6. AquaSafe Operation & Maintenance 7. AquaSafe UV Installation & Maintenance 8. AquaSafe UV Light Letter 9. AS1100 EZ with UV Post Aeration 10. UV-TUD Bulb Efficiency Engineering Plans 1. Plan for Setbacks and variances 2. Engineering Plan for Construction General Page 3 Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews,NC 28105 Phone:704-847-3031 mikelQLashEngineering.com Lash Engineering, Inc. May 25, 2022 John Hennessey NPDES Permitting Program Division of Water Quality Raleigh,NC.27699-1617 Re:Richard Beck Residence; Clay County Letter of Authorization Gentlemen: I have engaged Michael Lash, PE. with Lash Engineering, Inc. to assist me in preparing and filing a National Pollution Discharge Elimination System application for the above captioned existing single-family residence. This letter will serve to certify that I have designated him as my authorized representative for this application. Very truly yours, Prrittft A. Beck R,a 104 At, A , i3ci c Btesient r.eer.4,e4 4 Nomad Mountain Properties (828) 283-0430 General Page 4 Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews,NC 28105 Phone:704-847-3031 mikel@LashEngineerins.com Lash Engineering, Inc. May 11, 2022 John Hennessey NPDES Permitting Program Division of Water Quality Raleigh,NC. 27699-1617 Beck Property Request for General Permit This property is located near the town of Hayesville,NC off Compass Creek Drive in Clay County. Their existing septic system has failed, and they are looking for solutions to their timely problem. The existing house cannot acquire public sewer. The land on all sides is not available for lack of space. The soil has been"turned down"by the Health Department for any repairs and has requested the Owner to pursue a Direct Discharge Permit. The Owner is requesting a General Permit(NCG550000)and"Authorization to Construct" for a direct discharge system. The Watershed classification for Compass Creek is Class"C, Tr". If I can be of any further service,please do not hesitate to call. Sincerely, Michael Lash, PE. General Page 5 Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews,NC 28105 Phone:704-847-3031 mikel@LashEngineering.com Lash Engineering, Inc. Project Summaryfor: Beck Residential Direct Discharge 51 Compass Creek Drive Clay County, N.C. The project is located at 51 Compass Creek Drive, close to the town of Hayesville, NC. in Clay County. It is an existing 8-bedroom building (1982) with an existing septic tank and leaking (overwhelmed) disposal system. This lot is surrounded by homes in a residential area. The existing disposal system was originally permitted in 1982. According to the Clay County Health Department Permit and verified in the field, the existing disposal consists of a gravel type drain field on the side of the house with three lines at 30' long by 15'wide. This system seems to be suitable for a 3-bedroom house, but the house was built with 8- bedrooms (no one can explain how this happened). The house was sold to Mr. Beck and he is fixing the place up, and renovating the property. Mr. Beck went to the Health Department to have them upgrade the permit to match the number of bedrooms. The Health Department made a soil's evaluation and turned down the nearby soils for a subsurface repair system due to lack of space. The Health Department then recommended investigating a direct discharge permit. The Health Department report is included in this application. The proposed discharge point is on the property— so no easements will be required. This is shown on the plan. A direct discharge system for the wastewater effluent was proposed because of the lack of adequate available soils either on or nearby. The Watershed Classification for this area is "C-Tr", as a tributary of the Tusquitee Creek watershed. The watershed is 3.17 sq.mi. and has been submitted to the USGS. The system will consist of adding a new Aqua-Safe PreTreat unit, and an Ultraviolet disinfection unit outside the Aqua-Safe unit to sterilize the effluent before it is discharged into the creek. The system will operate by gravity. There is no need for a pump. The TS II treatment will be facilitated by a new Aqua-Safe Model AS 1100L EZ TOP unit with an Ultraviolet disinfection unit as the last step to sterilize the effluent before it is discharged into the creek. The Aqua-Safe Treatment system has the Onsite Water Protection Section Approval numbers RWTS-83 & 87 and can be supplied in fiberglass. The proposed system will be designed for a total flow of 1100 gallons per day. This Aqua- General Page 6 Safe facility typically treats residential effluent to close to single digits so acquiring the States requirements of 20, 20, 20 should be easily facilitated. The AquaSafe unit is at the house with a grade change of about 10' to the discharge location at the creek so a pump should not be necessary. The system will be able to function by gravity. A 4" Sch.40 PVC Discharge Line with a few cleanouts (for directional changes) are proposed to assist with alignment, cleaning, and maintenance. The head losses of the effluent passing through the UV light are very minor (negligible) as it works with gravity flow. Should the UV light fail to operate, a voltage signal is sent to the control panel and an alarm is sounded. The system utilizes an Aqua-Safe Control Panel that has been designed to work for these units. The panel is housed within a NEMA 4X enclosure that is setup for the agitator and internal monitoring of the system. The processor constantly evaluates the water usage and meters out the effluent discharge to the disposal area at the appropriate interval to assure proper effluent treatment. The major system components (AquaSafe & pump tank, chambers, etc.) have been reviewed and approved for this application by the State of North Carolina, and many systems of this type have already been installed and certified. The system shall be installed by a certified contractor, and the entire system shall be certified as complete and operational by Lash Engineering, Inc. The wastewater system must be inspected twice a year to check for leaks, make sure the control panel and the alarms are working, run the system through a manual cycle, and verify valves and filters are working properly. The system should be checked thoroughly for leaks, ponding, or erosion, which could indicate. The Engineer has provided the Owner a Check Sheet for evaluating the system on a monthly basis. Any issues should be brought to the attention of the Operator. Certification & Final: Lash Engineering, Inc. in conjunction wi th Tim Barbee (operator), and the installer will provide a final certification packet including a letter stating that the system was installed properly, and that all connections and programming have been checked. If significant changes have occurred during the construction process, then a final "As-Built" drawing showing those changes made due to site-specific conditions will be supplied to the Owner along with the Certification. Please contact Lash Engineering, Inc. if you have any questions or concerns at 704-847-3031. General Page 7 J1~ • ez of • -='-: a PUBLIC HEALTH DEPARTMENT x . _ K A CAR-, December 6th.2021 Property Owner: Richard Beck 2656 Findlay Avenue SW Palm Bay FL 32908 Property Address/Location: 51 Compass Creek Dr. Hayesville,NC 28904,Parcel#558200815136 Re: property owners request to October 28th,2021 application denial of improvement permit for above property address. Dear Mr.Beck, The Clay County Health Department,Environmental Health Division on October 28th,2021 denied your application from an improvement permit for the expansion of the existing 3-bedroom 360 gallons per day on-site wastewater system installed in 1982 to an 8-bedroom 960 gallons per day on-site wastewater system.The residence currently has 8 bedrooms as referenced and taxed as such by the Clay County Tax Office.Our office nor the Clay County Building Department has no record of when the residence was expanded from a 3 bedroom to an 8 bedroom.The residence is currently undergoing a remodel to upgrade and improve the residences 8 bedrooms. If you have any questions,please contact the office at 828-389-8326. i Sincerely,� ) / ( /z oe J c Sellers, REHS Environmental Health Program Coordinator Clay County Health Department joesellers@clayhdnc.us General Page 8 Beck Direct Discharge Wastewater Facility National Pollutant Discharge Elimination System FOR AGENCY USE ONLY (NPDES) Date Received Division of Water Resources Application for SURFACE DISCHARGE Year Month Day Environmental Certificate of Coverage(COC)Under Quality General Permit NCG550000 Certificate of Coverage(COC) For Single-Family Residences and Similar Discharges N C G 5 5 100%-domestic wastewater-<1,000 gallons per day Check# Amount This existing 8-bedroom house was constructed in 2005. Unfortunately it was permited as a 3-bedroom and the disposal system was installed as a 3-bedroom. Current Owner is renovating the house and needs all 8-bedrooms. The Health ,Assigned to: Department cannot find enough available land for the full 8-bedrooms. The Health Department recommended this NCG550000 Direct Discharge permit. The Division of Water Resources will not accept an application package unless all instructions are followed. Failure to submit all required items may result in the application being returned. For more information, visit the Water Quality Permitting Section's NPDES Permitting Unit website. (Press TAB to navigate form) 1. Regional Office Contact: Please contact your DWR Regional Office before submitting this application.If you have not met with your appropriate DWR Regional Office Representative,the application will be returned. Please list the DWR Regional Office representative(s)with whom you have discussed this project: Name(s): Mikal Wilmer Asheville Regional Office Office: 828-296-4686 Cell: 828-989-9695 Mikal.Wilmer@NCDENR.GOV Date: Date not available. 2. Owner's Contact Information: Applicant Type: ®Individual ❑Corporation ❑Partnership Owner Name and Title: Richard Beck Street Address: 2656 Findlay Avenue FL City: Palm Bay State: Zip:32908- Telephone#(H): 585-746-1515 Telephone#(W): Cell/Mobile#: 585-746-1515 Email:info@mitchellcountyanimalrescue.org 3. Location of FacilityProducingthe Discharge: Please list the address of the facility.If facilityis not yet � ty constructed,give street address or lot number. Street Address: 51 Compass Creek Drive City: Hayesville State: NC Zip: 28904- County: Clay Telephone#: 585-746-1515 Cell/Mobile#: Website: There is no website for this facility 4. Site-Location Narrative: Please describe how to get to the facility from the nearest town,major highway or identifiable roadway intersection(use street names,state road numbers,and/or distances and directions). Heading East on Tusquittee Road, continue past Taxi Drive, Cold Branch Road, and Compass Meadows Drive until you reach Compass Creek Drive. Take a left onto Compass Creek Drive, and the site will be on your left. Page 1 of 6 Revised:A. Orlando NPDES 21 Sept2017 General Page 9 Application for Certificate of Coverage(COC) and/or Authorization to Construct(ATC) under General-Permit NCG550000 5. Describe the nature of the project. ["New"means has not yet been physically constructed,"existing" means system already physically exists.Please see 15A NCAC 02H.0103(11) for further clarification]. ❑ Installation of a New Wastewater Treatment System(If yes, skip to Number 9.) ❑ Expansion of an Existing Wastewater Treatment System(for example,adding bedrooms)(If yes, skip to Number 9.) ® Replacement of an Existing Wastewater Treatment System(If yes, go to Number 6.) 6. Describe the Existing Wastewater Treatment System: ❑ Conventional Septic Tank/Leach-field—Discharge to Sub-Surface Soils.If previously permitted, please attach a copy of the permit or enter the permit number Permit issued 2-24-1982. If you are not aware of an existing permit,check here. ® included in submittal book ❑ Sandfilter—Discharge to Surface Waters [or other,as defined 15A NCAC 02H.0103(11)].If previously permitted,please attach a copy of the permit or enter the permit number If you are not aware of an existing permit,check here. ❑ ❑ Filter Media System(Pod System)—Discharge to Surface Waters [or other,as defined 15A NCAC 02H.0103(11)]. If previously permitted, please attach a copy of the permit or the permit number.If you are not aware of an existing permit,chec Jere. ❑ Other ❑ Check here if submitting proposal for a new system or if no treatment system exists. 7. Check all EXISTING wastewater treatment components: ® Septic tank ❑Dosing tank ❑ UV disinfection ❑Primary sand filter ❑ Secondary sand filter ❑ Recirculating sand filter(s) ❑Chlorination ❑Dechlorination ❑ Other components: ❑ Self-Contained POD system [describe] ®Leach Field ❑Post Aeration (sped type) 8. Provide Details of Single-Family Residence(SFR)or Similar Facility: a) Type of facility: ®Residential ❑Commercial ❑Other: b) Amount of wastewater discharged: Existing house has 8-bedrooms. - Residential:Number of bedrooms 8 x 120 gallons per bedroom= 960 gallons per day(flow) - Commercial: How many employees?(25 gpd/person) Page 2 of 6 Revised:A. Orlando NPDES 21 Sept2017 General Page 10 Application for Certificate of Coverage(COC) and/or Authorization to Construct(ATC) under General-Permit NCG550000 c) Is your existing treatment system failing? Yes ® No ❑ d) Has the Health Department formally condemned your existing system "unsuitable for repair?" Yes ® No ❑ If yes,please name the Health Department[local,county,or state],and provide the site- inspection date[attach Health Department's judgement letter, if available]: Clay County Health Department 10/28/2021 Denial Letter is included in submittal book. If previously permitted[local,county,or state],provide permit number and date issued [attach copy, if available]: Not Available 9. Check all PROPOSED new system components ❑ Septic tank ❑Dosing tank ® UV disinfection: ❑Primary sand filter ❑ Secondary sand filter ❑ Recirculating sand filter(s) ❑Chlorination ❑Dechlorination ® Other components: AquaSafe PreTreat Unit ❑ Self-Contained POD system [describe] ❑Post Aeration(sped type) ❑ Proposed Modifications to Existing Treatment System-Explain in detail the nature of the modification. Attach all site maps,plans and specifications,signed by an NC Certified Engineer. If prepared by others,plans must conform to 15A NCAC 02H.0139. Only the existing septic tank will be used. The rest of the system is proposed. Proposed New Treatment System for Surface Discharge(not constructed)-Attach all site maps, plans and specifications,to be signed by an NC Certified Engineer. If prepared by others,plans must conform to 15A NCAC 02H.0139.The existing 800g precast tank will be used behind a new 1,000g septic bank that will gravity feed to a pretreat tank with an UV light.Plans are attached and also part of the Submittal Book Expanding Flow?-Doyou propose to increasepermitted or existingflow? X Yes No P g P P ❑ ❑ Provide details of the Proposed NEW Discharge [Flow and Source Water]: Technically the answer is yes but only because it wasn't permitted for 8- ® Check if same as 6. bedrooms originally. The existing house is not being expanded from its original construction. • Existing:Amount of wastewater currently discharged: Number of bedrooms 8 x 120 gallons per bedroom= 960 gallons per day to be permitted(design flow) Expanding: Amount of wastewater proposed to be discharged:Number of bedrooms 8 x 120 gallons per bedroom= 960 gallons per day to be permitted(design flow 10. Evaluate Alternatives to Discharge to Waters of the State.Please address the feasibility of discharge alternatives as instructed in the NCDEQ Engineering Alternatives Analysis(EAA) Guidance Document found here. (Note: Evaluation for endangered species is not required.) There is an EAA Section in the submittal book with all of these reports. a) Connection to an Existing Wastewater Treatment System-Provide the distance to the nearest connection,such as a regional or municipal sewer system,and the Page 3 of 6 Revised:A. Orlando NPDES 21Sept2017 General Page 11 Application for Certificate of Coverage (COC) and/or Authorization to Construct(ATC) under General-Permit NCG550000 estimated cost per foot to connect including fees. This is part of submittal package. b) Land Application—Assess the land application disposal alternatives such as spray irrigation,drip irrigation,individual/community onsite subsurface systems, and/or innovative ground-absorption. Questions to consider: This is part of the EAA submittal package. (1) Are on-site soils suitable for land application? Yes ❑ No (2) Is there sufficient area on-site? Yes ❑ No c) Wastewater Reuse—Evaluate reusing all or a portion of the wastewater generated, such as for golf course irrigation,crop irrigation(e.g.,hardwood or pine plantation, grasses), athletic field irrigation, landscape uses,and/or commercial/industrial uses. This is part of the EAA submittal package. d) On-Site Soil Evaluation—Submit an evaluation of the soils on-site, documented by a certified report from a NC Professional Soil Scientist, or by your local or county health department report(if available). The Local Health Department made an evaluation and is part of their"Denial Letter". e) Cost of Alternatives—Provide an estimation of the cost of each discharge alternative or combination of alternatives.Included in submittal package along with b-d. This is part of each report and the summary sheet. 11. Provide Regional Information: Please provide the following information. If you need assistance in obtaining this information,please contact your local DEQ regional office. a) Stream Classification-Verify the stream classification for the nearest downgradient named waterbody. The NC Surface Water Classification map can be found by clicking here. Classification: C:Tr b) Is it a High-Quality Water?If so,check if it is by definition or by designation?In order to check this,ask the Planning Unit. No. c) Map-Provide a map locating the nearest downstream waters-of-the-State(i.e. where the effluent reaches an unnamed tributary,creek, stream,river,or lake via any surface-water conveyance). Part of Submittal Package A section of the Submittal Book has this information. d) Site Evaluation-Contact DEQ's local Regional Office for a site evaluation to confirm the proposed discharge flow path to the nearest waters-of-the-State. The wastewater/stream confluence and stream class must be verified in the field by DEQ's Regional Staff. Please list the Regional Office staff member you contacted for the inspection. A package was mailed. Mikal Wilmer Cell: 828-989-9695 Office: 828-296-4686 Mikal.Wilmer@NCDENR.GOV e) Flow Path-Display graphically the flow path of the discharge to the nearest surface Waters of the State. Document any potential hydrologic trespass or right-of-way infringement on any neighboring property(i.e. note all properties encountered prior to reaching waters-of-the-State). Part of Submittal Package A Site Plan created on a boundary survey shows that the creek is on this property and is part of the plans included with this submittal. General Page 12 Page 4 of 6 Revised:A. Orlando NPDES 21 Sept2017 Application for Certificate of Coverage (COC) and/or Authorization to Construct (ATC) under General-Permit NCG550000 f) 7Q10/30Q2 Estimate-Contact USGS J. Curtis Weaver(919-571-4043)to provide the estimated 7Q10 and 30Q2 stream-flow estimates for the first downstream point-of-contact with waters- of-the-State. The Project has been accepted for review but has not been completed. The report will be forwarded when received. 11. Certificates of Coverage/Notices of Intent to Discharge/Authorizations to Construct-Check ALL of the following information has been provided. Incomplete Applications will be returned. ® An original letter[two(2)copies] requesting coverage under NCG550000. ® This application [two(2)copies].Your signature on this application,certifies that you are legally responsible for the proposed treatment system (see page 6 of 6)for the COC/NOI/ATC. ►1 A check or money order for$60.00 permit fee made payable to NCDEQ. 12. Additional Application Requirements a) Narrative Description of the treatment system.This narrative should present treatment components in order of flow—influent to outfall, including anti-erosion structures and sample-port location(s). An Engineers Summary Report is included in the application along with a Maintenance Form. b) Final Plans and Specifications for a wastewater treatment system shall be signed by a North Carolina-registered Professional Engineer, or if prepared by others,must conform to I 5A NCAC 02H .0139. All documents are to be stamped "Final Design-Not Released for Construction." Submittal shall include a site map showing the proposed outfall and the effluent proposed path to surface waters-of-the-State.(see Item 1 for location verification by DWR Regional Office staff) c) Submittals by a Consulting Engineer or Engineering Firm shall include: 1. A copy of your written authorization to represent, signed by the legal permit Applicant;and Included in Submittal. 2. Upon completion of proposed work,a signed copy of DWRs Engineer's Certification form attesting that the project was completed in accord with the DWR approved COC/ATC,as issued. This will be completed when it is appropriate. ******************************************************************************* CERTIFICATION I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true,complete, and accurate. Printed Name of Person Signing: ?/e//l4.0 P 8 c' Title: '1g6.4Sy,e4-Al vm Vet V,t 5 d-L (Please review 15A NCAC 02H.0106(e)for defmition of authorized signing officials) 919/z Z Click here to enter a date. (Signature of Applicant) (Date Signed) General Page 13 Page 5 of 6 Revised:A. Orlando NPDES 21 Sept2017 Application for Certificate of Coverage (COC) and/or Authorization to Construct(ATC) under General-Permit NCG550000 NOTE: Treatment System Maintenance is Required-Upon receiving a Certificate of Coverage/Authorization to Construct(COC/ATC),the Division recommends that the Permittee solicit manufacturer-certified training,or solicit a qualified contractor or service to regularly inspect and maintain this treatment system. The Permittee is responsible under this COC/ATC to maintain all components of the approved treatment system, designed to meet Surface Water Quality Standards [see attached Operation and Maintenance Agreement]. Compliance duties include: • paying your annual fee [due on the anniversary of COC/ATC effective date], • following the manufacturer's guidelines, • conducting and documenting inspections, in compliance with General Permit NCG550000, • establishing sources for OEM spare parts and supplies, • taking discharge samples for analysis,and logging the results, • making necessary repairs, documenting said maintenance in logs,and • keeping logs onsite for the life of the permit,available for DWR inspection. North Carolina General Statute 4 143-215.6B provides that: Any person who knowingly makes any false statement representation,or certification in any application,record, report,plan,or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the Commission implementing this Article,shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars($10,000). 18 U.S.C. Section 1001 provides a punishment by a fine or imprisonment not more than 5 years,or both,for a similar offense. Application must be accompanied by a check or money order for$60.00 made payable to: NCDEQ • • • • • Mail this application and one copy of the entire package (with check) to: NCDEQ/DWR/NPDES Attention: John Hennessy, Supervisor Compliance and Expedited Permitting Unit 1617 Mail Service Center Raleigh,North Carolina 27699-1617 Attn: John Hennessy Note: Submission of this document insures DWR's consideration, but does not guarantee issuance of a Certificate of Coverage/Authorization to Construct. General Page 14 Page 6 of 6 Revised:A. Orlando NPDES 21 Sept2017 , ., • . • ,. . . , , ,, .. , ., • , . _ ...,. 4164 LASH ENGINEERING, INC. ?)ZEgriVD") 1104 CINDY CARR DRIVE MATTHEWS, NC 28105 DATE 66-7783i2531 _ Z- Z. <2. ,-V4A-i TO rti;7 1 2, AX 1HE ORDER OF $ 5 la/ - el sge“aty Fm.ares DOLLARS CID CD .7 uiTRULIANT FEDERAL CREDIT UNION 800-822-0382 WWW.TRULIANTFCU.ORG FOR IIII 0 0 Li L 6 1-i II° 1 gs 253 1 ? ?Eli 3 2g: Le 0 0 0 5 240893 LH° .!- i r:*rd Ecological Tanks, Inc. Certificate of Completion Michael Lash, PE Lash Engineering, Inc. Has completed the requirements of Aqua Safe® and is certified to design treatment and disposal systems using the Aqua Safe® line of wastewater products. Granted: April 16, 2020 George E. Johnson, III President, Ecological Tanks, Inc. Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews,NC 28105 Phone: 704-847-3031 m ikel(cr�LashEn gineering.com Lash Engineering, Inc. TABLE OF CONTENTS EAA/EPA 1. Table of Contents 2. EAA Summary 3. EAA Alternative"A" Public Sewer Availability a. Email from Clay County b. Alternative"A" Public Sewer Evaluation 4. EAA Alternative"B" Land Application Option a. Alternative"B" Subsurface Evaluation b. Subsurface Sketch c. Alternative"B" Surface Evaluation 5. EAA Alternative"C"Wastewater Reuse Evaluation 6. Health Department Evaluation 7. EAA Alternative"D" Direct Discharge 8. EAA Summary Alternatives Report 9. NPDES Form 1 10. NPDES EPA Form 2a EAA Page 1 Mr Beal My name is Eh Rubaakc anon am oori a rdtb Mischael Lash Enaireamg Fm an ammeee that a m the process of subnumne an appheanae fora Direct Daschaee pesmt for SE Berk to the State He bas poor soil qualm foe ern'mrf a subo,aface aaluam and needs to agmre a Daect Mechem Pearna.We/rave been m close contact earth the Clan Conn,Health Department Part of the application concerns haw he away the public sea Is available 1 need to Include 0sx amh-srs m no report. Lot rnromrataon a: Compass Creek Dr. Tax Parcel.658200815126 I realh oM need too thwas:t e fmt a a map that shows the al adable sewer that n closest to the properly(even if Ws far away)The second theta can be written m the reply anal and that is that there is m seer available at the sae and an plans for an esteesice ae currently beme planned. If you have ern'questions.please let me know. Thanks for vow torn CP Ihstl 'o:Elin TruGMalnsk,; Thanks for your email We do not nave any waterer sewer services near mat area nor i5 there any plans m the near future of running lines out that way The closest sewer line we have runs down Hwy 6110 ltay 175 end the closest water availability we have is at the McGlaeenry Farms subdivision on Hwy 61.It will be neat week before I can get you any actual maps snowing our closest infrastructure as I'maul of the office until next week In the mean while let me know if there s anything else 1 can help you with Thanks Dusty EAA Page 2 Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews,NC 28105 Phone:704-847-3031 mikel@LashEngineering.com Lash Engineering, Inc. Engineering Alternatives Analysis (EAA) Facility Name: Wastewater Facility for Beck Residence for Non-Municipal Applicant 51 Compass Creek Dr., Hayesville,NC. Clay County Alternative B; Public Sewer Extension Dustin Beal from Clay County was contacted for the availability of sewer for this property. Dustin points out that the nearest sewer is currently very far from the site and located within the Town of Hayesville. A map was provided that shows the approximate locations for the proposed Public Sewer. The distance to acquire this proposed public sewer is approximately 7 miles away. Approximate cost for sewer main: 36,960'/8" gravity sewer laid adjacent to the existing road @ $140.00/ft. for pipe, manholes, surveying and installation » $5,174,000. The City could require the extension to go past the property to the end of the road,which is required for developments but for this example we will assume that it stops at the house. In addition to the cost of installation,the costs of maintaining a 36,960 ft. of 8"main with 40 manholes over a 30-year period could potentially be devastating. So,the sewer main would need to be turned over to the City for ownership and maintenance. Tap fees» $800.00; Connection fee» $1,000.00 Total Approximate Cost for installation» $5,175,800 The Present Cost Analysis is included: Present Value Cost Analysis: PV = Co+ C[(1+r)n-1 /r(1+r)"] PV=Present Value of Costs Co=Costs occurred in Present Year. $5,175,800(installation costs) C=reoccurring costs The City would take over maintenance costs. $0.00 Yearly Sewer Bill @$50/mth=> 12 x 50= $600.00 Total outlay of funds per yr.= $600.00 EAA Page 3 t=time in years. (t=0 is the first year) n=Ending year of the Facility(use 20 years) r=current EPA discount rate(this value could be determined by the website provided or Google search)therefore,we used the value from the example of 5.625% PV=$5,175,800+$600.00[(1+0.05625)20-1 /0.05625(1+0.05625)20] PV=$5,175,800+600.00[1.9877/0.1889] PV=$5,175,800+$600.00[10.520] PV=S5,182,112 Conclusion: Because the existing sewer is far away from the house the costs are cost prohibitive for a single homeowner. Extending these costs over a 30-year period and the costs of providing sewer to a single residence is cost prohibitive. EAA Page 4 L Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews,NC 28105 Phone:704-847-3031 mikel@LashEngineering.com Lash Engineering, Inc. Engineering Alternatives Analysis (EAA) Facility Name: Wastewater Facility for Beck Residence for Non-Municipal Applicant 51 Compass Creek Dr.,Hayesville,NC. Clay County Alternative B; Land Applications- Subsurface The land around the site is occupied by existing owners. The properties with homes were built in the 2000's and have no available land with good soils for repair. According to the Clay County Health Department,the Beck household has insufficient space for a proper repair area, and low-quality soils. Each of the adjacent homeowners have their own existing sewer systems. There is no other available land onsite for subsurface (or surface drip). There are no golf course type businesses that could use a treated effluent for irrigation or something similar. Unfortunately none of the Soil onsite or nearby is available. However, should land become available,the following would apply: Similar land in this area is being sold for approximately $50,000 per acre. Access to the property would need to be by current road rights-of-way. The closest land to the lot is approximately 580' away. Per aerial photography an area of land up Compass Creek Dr. and upslope was at a reasonable slope for a disposal area. The same wastewater treatment system would be utilized at the house with the same design for collection and treatment. The effluent from the treatment process would then need to be pumped to the available site approximately 580 feet away. The existing soils on the property (three)and adjacent land according to the U.S.Dept of Agriculture and the associated Soils Maps, consist of Ud(Loamy Udorthents). This soil map unit has good permeability and depth,but unfortunately does not provide a large enough space for a wastewater system on the property. Another soil nearby is a RsA EAA Page 5 (Rosman Sandy Loam), 1 to 2%slopes. This soil type also has good permeability and depth,but is only on a small portion of the property. The final soil type is classified as DgB (Dellwood gravelly loam), 5% slopes.This soil is moderately drained,and is occasionally susceptible to flooding. Overall,these soil types can be considered Class III,allowing us to use an assumed LTAR of".5". Therefore,using an LTAR of"0.50", the 1000 gpd disposal requirement would require 1000/.5 =2,000 sf. of disposal area. Also,need an equivalent Repair Area =>2,000 x 2=4,000 sf or 0.1 acres. Utilizing setbacks and required land geometry to install the drip tubing on contour the required land for disposal would be approximately 0.23 acres. Additional Costs for such a system above what would be required for the Direct Discharge are summarized below: Additional Equipment at House(over what is required for the Direct Discharge): Pump Tank= 1,750-gal tank(for a couple days storage) 1,750g tank+pump, floats,control panel, etc. _ $15,000 Distribution System: 1. 2"Force Main to get effluent to disposal site which would be offsite. Using 580 feet of 2"PVC Force Main @ $35/ft= $20,300 Disposal/Nitrification Field would utilize a drip system disposal and an associated Headworks unit. Headworks Unit @ $2,500 each plus$1,500 in appurtenances= $16,500 2,000sf of area would require 1,000 ft. of drip tubing @ $3.20/ft= $ 3,200 Land Acquisition: 0.25 acres of land @$50,000/ac= $12,500 Access Road=200' @ $150/ft. _ $30,000 Total Rough Costs for initial installation=> $97,500 Present Value Cost Analysis: PV = Co + C[(1+r)n-1 / r(1+r)nJ PV=Present Value of Costs Co=Costs occurred in Present Year. $162,340(installation costs) C=reoccurring annual costs Annual Inspections: $600 Sample Collection: $100 Tank Pump Out: $100 Lab Work: $100 Pump Replacement: $300 EAA Page 6 Drip Tubing Repair: $200 Access Road Repair: $200 Total outlay of funds per yr. =$1,600 t= time in years. (t=0 is the first year) n=Ending year of the Facility (use 20 years) r=current EPA discount rate(this value could be determined by the website provided or Google search)therefore,we used the value from the example of 5.625% PV=$97,500+$1,600[(1+0.05625)20-1 /0.05625(1+0.05625)21 PV=$97,500+ 1,600[1.9877 /0.1889] PV=$97,500+ $1,600[10.520] PV=$114,332 Comparatively,this cost is prohibitive as the land is worth $42,000 EAA Page 7 Disposal • --.,Site 170' 410 .00 Nel EAA Page 8 % Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning ut 1104 Cindy Carr Drive Matthews,NC 28105 Phone:704-847-3031 mikel@LashEngineering.com Lash Engineering, Inc. Engineering Alternatives Analysis (EAA) Facility Name: Wastewater Facility for Beck Residence for Non-Municipal Applicant 51 Compass Creek Dr.,Hayesville,NC. Clay County Alternative B; Land Applications—Surface Drip or Spray The land around the site is occupied by existing owners. The properties with homes were built in the 2000's and have no available land with good soils for repair. According to the Clay County Health Department,the Beck household has insufficient space for a proper repair area,and low-quality soils. Each of the adjacent homeowners have their own existing sewer systems. There is no other available land onsite for subsurface (or surface drip). There are no golf course type businesses that could use a treated effluent for irrigation or something similar. Unfortunately,none of the Soil onsite or nearby is available. However, should land become available,the following would apply: Typical reasons for utilizing a surface system are when a subsurface solution is not available. These would include but not be limited to a high seasonal water table, less than 18" of permeable earth,or the residual material is full of clays or impermeable material. Similar land in this area is being sold for approximately $50,000 per acre. Access to the property would need to be by current road rights-of-way. The closest land to the lot is approximately 580' away. Per aerial photography an area of land up Compass Creek Dr. and upslope was at a reasonable slope for a disposal area. The same wastewater treatment system would be utilized at the house with the same design for collection and treatment. A pump tank would have to be added or a Septitech type treatment system utilized that had a pump tank built into the system. The effluent EAA Page 9 from the treatment process would then need to be pumped to the available site approximately 580 feet away. The existing soils on the property (three)and adjacent land according to the U.S. Dept of Agriculture and the associated Soils Maps, consist of Ud(Loamy Udorthents).This soil map unit has good permeability and depth,but unfortunately does not provide a large enough space for a wastewater system on the property. Another soil nearby is a RsA (Rosman Sandy Loam), 1 to 2%slopes. This soil type also has good permeability and depth, but is only on a small portion of the property. The final soil type is classified as DgB (Dellwood gravelly loam), 5%slopes. This soil is moderately drained, and is occasionally susceptible to flooding. Overall,these soil types can be considered Class III, allowing us to use an assumed LTAR of".5". Therefore,using an LTAR of"0.50",the 1000 gpd disposal requirement would require 1000/.5 =2,000 sf. of disposal area. Also,need an equivalent Repair Area =>2,000 x 2=4,000 sf or 0.1 acres. Utilizing setbacks and required land geometry to install the drip tubing on contour the required land for disposal would be approximately half an acre. Additional Costs for such a system -above what would be required for the Direct Discharge are summarized below: It would be an advantage to minimize the amount of land that would need to be acquired. Surface Drip and Spray require wide setbacks to protect the adjacent property owners. Spray systems require the most of the two. The drip option would be utilized to minimize the amount of land required for a surface system. Land requirements for surface systems are sized based upon the use of a water balance. Such a system calculates on an imaginary acre of land an estimation of the amount of rainfall (input into the soil)and an associated amount of output being evaporation,plant uptake and soil permeability. The difference between the two {outputs—the input (assuming a positive number)) is the amount of effluent that the acre parcel of land can receive. An assumption for the results of a water balance will be to choose a value that is appropriate for the DgB Soil Type,which is a type of soil with a high seasonal water table, so the value is not a minimum but a midrange value. The amount of effluent from the project is 1000 gpd. The amount of area required is approximately: 1000 gals 365 days 12 in. 1 cf 1 yr. = 14,281 sf. day yr. ft. 7.48-gals 41 in. Tubing requirement for area is: 14,281 sf./(50 /12 )spacing=3,427 feet of driptubing g This amount of drip tubing would require the standard residential Headworks unit. A Repair area for a surface drip system is not required. The 14,281 sf of space is the useable size for the disposal. Assuming a square, it would equate to a 120' x 120' area. EAA Page 10 Applying the required 50' setbacks to property lines and needing a 25' work area on one side equates to an area approximately 220' x 245' or 1.24 acres. The system would need to be treated to TS II standards and further treated with chlorine or UV Light for pathogens. Additional Costs for such a system above what would be required for the Direct Discharge are summarized below: Additional Equipment at House: Pump Tank=4,000-gal tank(surface drip requires storage) 4,000g tank+pump, floats, control panel,etc. = $ 8,000 UV Light&Control Panel, Gauges, Sensors, Valving etc.= $18,000 Distribution System: 1. 2"Force Main to get effluent to disposal site which would be offsite. Using 5801f. of 2"PVC Force Main @ $35/ft= $20,300 Disposal/Nitrification Field would utilize a drip system disposal and an associated Headworks unit. Headworks Unit @ $2,500 plus $1,500 in appurtenances= $ 4,000 14281sf. of area would require 3,427 ft. of drip tubing @ $3.20/ft= $ 10,970 Land Acquisition: 1.24 acres of land @ $50,000/ac= $ 62,000 Access Road=200' @ $150/ft. _ $ 30,000 Shed&Equipment=>$5,000+$1,000= $ 6,000 Total Rough Costs for initial installation=> $159,270 Present Value Cost Analysis: PV = Co + C[(l+r)n-1 / r(1+r)'J � PV=Present Value of Costs Co=Costs occurred in Present Year. $191,965(installation costs) C=reoccurring annual costs Annual Inspections: $600 Sample Collection: $300 Tank Pump Out: $100 Lab Work: $200 Pump Replacement: $300 Drip Tubing Repair: $200 Access Road Repair: $200 Total outlay of funds per yr. =$1,900 t= time in years.(t=0 is the first year) EAA Page 11 n=Ending year of the Facility (use 20 years) r=current EPA discount rate(this value could be determined by the website provided or Google search)therefore,we used the value from the example of 5.625% PV=$159,270+$1,900[(1+0.05625)20-1 /0.05625(1+0.05625)20] PV=$159,270 + 1,900[1.9877/0.1889] PV=$159,270+ $1,900[10.520] PV= $179,258 Comparatively,this cost is prohibitive. EAA Page 12 v Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning L1104 Cindy Carr Drive Matthews,NC 28105 Phone:704-847-3031 mikel@LashEngineering.com Lash Engineering, Inc. Engineering Alternatives Analysis (EAA) Facility Name: Wastewater Facility for Beck Residence for Non-Municipal Applicant 51 Compass Creek Dr., Hayesville,NC. Clay County Alternative C; Wastewater Reuse The land around the site is developed and/or occupied by existing owners. Each of the adjacent owners have their own existing sewer systems. Water Reuse is a wonderful way of utilizing a resource that otherwise would be discarded. Unfortunately,there are just a few ways that treated wastewater effluent can be used as a reusable resource. Common avenues of reusable options would include irrigating with the effluent at a plant nursery, a golf course, landscaping or even a county park. Another avenue of reuse could involve the residential property itself. The effluent could be used as grey water for flushing toilets within the house which would not eliminate the effluent, but it would significantly reduce the amount of water used by the home. In a practical way however,the proposed house will have its plumbing built into the house. Therefore,the use of the effluent as grey water is not an option. There are also no nurseries or golf courses available for use. The proposed house does have landscaping areas,but the underlying soils are not suitable for any type of permeability. However, should an area become available within proximity (within 1 mile)then the option could become available, and the following would apply for a Water Reuse Option: The same treatment system could be utilized for the reuse option. A pump tank would have to be added or a Septitech type treatment system utilized that had a pump tank built into the system. The effluent from the treatment process could be pumped to the facility that will utilize the treated effluent. EAA Page 13 The amount of effluent from the house is 960 gpd. A facility that could utilize this amount of effluent on a daily basis would need to be able to utilize the extra effluent/water on a daily basis and would probably be currently supplied by a water well system or metered water from the City. The effluent from the house would supplement their usage but probably not replace it and there would only be certain aspects of their water demand where a treated effluent could be utilized. This report will assume that such a facility exists as a golf course as that is the simplest and most inexpensive way of reuse. The effluent will be used to supplement their sprinkler/irrigation system for their greens and fairways. Some golf course facilities have an onsite pond that is fed by rainfall but is also water well subsidized as needed. Their irrigation system is fed by pumping from this pond on almost a daily basis. Metered water from the City would be expensive to use for irrigation. The house effluent would need to be treated to at least TS II standards and further treated with an ultraviolet light for pathogen protection. Once treated the effluent would need to be pumped through a 2" force main to the holding pond of the golf course facility so that it could supplement the golf course facility. The golf course would probably be located near an onsite pond(utilizing the golf course pond landscapes)and be within 1 mile of the house. The force main will need to be installed through some property but predominantly adjacent to existing highways within the City/State Right-of- Ways and be installed according to DOT Standards. Costs for such a system are summarized below: Additional Equipment at House: Pump Tank=4,000-gal tank(needs required storage) 4,000g tank+pump, floats,control panel,etc. = $8,000 Additional Pumps, Valving, etc. for Reuse Rules= $15,000 UV Light&Control Panel, Gauges,etc.= $8,000 Distribution System: 1. 2"Force Main to get effluent to disposal site which would be offsite. Using 5,280 If. of 2"PVC Force Main @ $30/ft= $158,400 2. Asphalt Repair(3,000'x 4')_> 12,000sf. of asphalt paving @$10/sf= $120,000 Golf Course Pond Improvements: Repair/Landscape Force Main installation in Golf Course= $30,000 Pond Improvements for outlet of pipe= $15,000 Backflow Prevention, Valving, & appurtenances $5,000 Total Rough Costs for initial installation=> S3$9,4Q0 EAA Page 14 Present Value Cost Analysis: PV = Co + C[(l+r)n-1 / r(1+r)1 PV=Present Value of Costs Co=Costs occurred in Present Year. $359,400(installation costs) C=reoccurring annual costs Annual Inspections: $600 Sample Collection: $750 Tank Pump Out: $100 Lab Work: $500 Pump/Parts Replacement: $600 Access Road Repair: $500 Total outlay of funds per yr.=$3,050 t= time in years. (t=0 is the first year) n=Ending year of the Facility (use 20 years) r=current EPA discount rate(this value could be determined by the website provided or Google search)therefore,we used the value from the example of 5.625% PV=$359,400+$3,050[(1+0.05625)20-1 /0.05625(1+0.05625)201 PV=$359,400+ 3,050[1.9877/0.1889] PV=$359,400+ $3,050[10.520] PV= $391,486 Comparatively,this cost is prohibitive. EAA Page 15 dal d �aG t y PUBLIC HEALTH DEPARTMENT CA� October 28th,2021 Property Owner: Richard Beck 2656 Findlay Avenue SW Palm Bay FL 32908 Property Address/Location: 51 Compass Creek Dr. Hayesville,NC 28904,Parcel#558200815136 Re: Application for Improvement Permit for an on-site wastewater system located at above referenced property address. Dear Mr.Beck, The Clay County Health Department,Environmental Health Division on October 28,2021 evaluated the above referenced property at the site designated on the site plan that accompanied your improvement permit application. According to the application the site is to serve an 8 bedroom home with a design flow of 960 gallons per day.The evaluation was done in accordance with the laws and rules governing wastewater systems in NC General Statute 130A-333 including related statutes and Title 15A,Subchapter 18A,of the NC Administrative Code,Rule.1900 and related rules. Based on the criteria set out in Title 15A,Subchapter 18A,of the NC Administrative Code,Rule .1940 through.1948,the evaluation indicated that the site is UNSUITABLE for a sanitary system of sewage treatment and disposal.Therefore,we must deny your request for an improvement permit. The site is unsuitable based on the following: Insufficient space for septic system and repair area(Rule.1945) Unsuitable for meeting required setbacks(Rule.1950) These severe soil and site limitations could cause premature system failure,leading to the discharge of untreated sewage on the ground surface,into surface waters,directly to ground water or inside your structure. EAA Page 16 �v A. �(G x _t 14 PUBLIC HEALTH DEPARTMENT sIiiii The site evaluation included consideration of possible site modifications,as well as use of modified, innovative,or alternative systems. However,the Health Department has determined that none of the above options will overcome the severe conditions on this site. A possible option might be a system designed to dispose of sewage to another area of suitable soil or off-site to additional property. For the reasons set out above,the property is currently classified UNSUITABLE,and no improvement permit shall be issued for this site in accordance with Rule.1948(c). Note that a site classified as UNSUITABLE may be classified as PROVISIONALLY SUITABLE if written documentation is provided that meets the requirements of Rule.1948(d). A copy of this rule is enclosed. You may hire a consultant to assist you if you wish to try to develop a plan under which your site could be reclassified as PROVISIONALLY SUITABLE. You may also explore under GS 130A-336.1,(Engineer Option Permit) GA 130A-336.2 (Alternative Wastewater System Approvals for Nonengineered Systems)and SL 2020-97 (LSS Permitting During Cornovirus Emergency)for the property. You have a right to an informal review of this decision. You may request an informal review by the soil scientist or environmental health supervisor at the local health department. You may also request an information review by the NC Department of Health and Human Services regional soil scientist. A request for informal review must be made in writing to the local health department. You also have a right to a formal appeal of this decision. To pursue a formal appeal,you must file a petition for a contested case hearing with the Office of Administrative Hearings,6714 Mail Service Center,and Raleigh,NC 27699-6714. To get a copy of a petition form,you may write the Office of Administrative Hearings or call the office at(919)431-3000 or download it from the OAH web site at http://www.ncoah.com/forms.html. The petition for a contested case hearing must be filed in accordance with the provision of NC General Statutes 130A-24 and 150E-23 and all other applicable provisions of Chapter 150B. NC General Statute 130A-335 (g) provides that your hearing would be held in the county where your property is located. Please note:If you wish to pursue a formal appeal,you must file the petition form with the Office of Administrative Hearings WITHIN 30 DAYS OF THE DATE OF THIS LETTER. The date of this letter is October 28th,2021.Meeting the 30 day is critical to your formal appeal. If you file a petition for a contested case hearing with the Office of Administrative Hearings,you are required by law(NC General Statute 150B-23)to serve a copy of your petition on the Office of General Counsel,NC Department of Health and Human Services,2001 Mail Service Center,and Raleigh,N.C.27699-2001. EAA Page 17 tiE ct Wit: ;° PUBLIC HEALTH DEPARTMENT •t Do not serve the petition on your local health department. Sending a copy of your petition to the local health department will not satisfy the legal requirement in NC General Statute 150B-23 that you send a copy to the Office of General Counsel,NC Department of Health and Human Services. If you have any questions,please contact the office at 828-389-8326. Sincerely, /114:4_ Justin Mintz,REHS Environmental Health Specialist Clay County Health Department justinmintzftclayhdnc.us EAA Page 18 L Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews,NC 28105 Phone:704-847-3031 mikel@a,LashEngineering.com Lash Engineering, Inc. Engineering Alternatives Analysis (EAA) Facility Name: Wastewater Facility for Beck Residence for Non-Municipal Applicant 51 Compass Creek Dr.,Hayesville,NC. Clay County Alternative B; Land Applications—Direct Discharge 4.Alternative D; Direct Discharge to Surface Waters. 1.The house is existing with the existing wastewater disposal system failing and all of the existing system is located on the property. The existing house has 8 bedrooms with a design flow of: 960 gpd.An Outfall was chosen that produces the least amount of disturbance to property and recreation,but can be visually"hidden"with landscaping. 2.This Direct Discharge system is designed utilizing the required TS II discharge with an UV disinfection process. 3.A Project Summary is included in this application with a complete set of revised plans showing the correct discharge location. 4.Present Value Cost Analysis: PV = Co+ C[(1+r)n-1 /r(1+r)n] PV=Present Value of Costs Co=Costs occurred in Present Year. $20,000(installation costs) C=reoccurring costs Annual Inspections: $400 Sample Collection: $100 Tank Pump Out: $50 Lab Work: $200 PreTreat Maintenance: $100 Pumps&UV Bulb replacement: $350 Total outlay of funds per yr.=$1,200 t=time in years.(t=0 is the first year) n=Ending year of the Facility(use 20 years) r=current EPA discount rate(this value could be determined by the website provided or Google search)therefore,we used the value from the example of 5.625% PV=$20,000+$1,200[(1+0.05625)20-1 /0.05625(1+0.05625)20] PV=$20,000+ 1,200[1.9877/0.1889] PV=$20,000+$1,200[10.520] PV = $32,624 This initial cost has been approved by the Owners for this facility. These annual costs(reoccurring)are acceptable parameters for this type facility. EAA Page 19 __ Lash Engineering, Inc. L Civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews,NC 28105 Phone:704-847-3031 mikel@LashEngineerina.com Lash Engineering, Inc. Summary for Engineering Alternatives Analysis (EAA) Facility Name: Wastewater Facility for Richard Beck for Non-Municipal Applicant 51 Compass Creek Dr., Hayesville, NC. Clay County This project is located at 51 Compass Creek Dr. near the City of Hayesville in Clay County. This is an existing commercial building originally built in 1982. The County and Regional office has investigated the property and surrounding areas. This house has an original "Block"septic tank with a disposal which has failed and is seeking a Direct Discharge Permit. The EAA is used to provide guidance to the regulating community for the evaluation of the proposed wastewater disposal alternatives. This report is focused on summarizing the Steps which are written in reports more detailed format as separate sections of the application. The EAA is divided into several steps: STEP 1: 1. Zero Flow Stream Restrictions. The treated effluent would be discharged into a creek with positive flow. Based upon in-field analysis, review of drainage basin, and past projects, we expect the USGS report to have 7Q10 and 7Q30 approvable results. Mr. Weaver has been sent a package for his official review. 2. Stream Classification for the Receiving Waters. This information was received and verified through the USGS office. The information is more detailed presented in the Watershed Classification Report of this application. The following is a summary information from the USGS: The outfall discharge is to Compass Creek. The surface water classification for this area is "C Tr"within the Hiwassee River Basin. 3. Basin wide Water Quality Plans: There does not appear to be any limitations on the Hiwassee River Basin that would limit the residential wastewater discharges. 4. Impaired Waters and TMDL's There were currently no TMDL projects listed for this part of the Hiwassee River Basin. EAA Page 20 5. Presence of Endangered Species. The project was submitted to the following: Rodney Butler Conservation Data Manager NC Natural Heritage Program Division of Land and Water Stewardship North Carolina Department of Natural and Cultural Resources A response letter from the Heritage Foundation is included in this application. The findings are summarized below: "there are no records for rare species, important natural communities, natural areas, and/or conservation/managed areas within the proposed project boundary." STEP 2: 1. Reasonable Projections for Population&Flow The Project is an existing house. After accounting for 8 bedrooms, a design flow of 960 gpd was decided upon. This design flow was calculated with 120 gpd per bedroom x 8 bedrooms for 960 gpd. This design flow was used in the analysis and in conformance with 15A NCAC 2H.0219(1). STEP 3: Evaluate technologically feasible alternatives: See individual Reports for Alternatives. Summary in Tabular Form is included below: TABULAR FORM FOR EAA SUMMARY: EAA Alternative Reports are included in this submittal that fully explores the options of Subsurface and Surface Drip systems. In summary: 1. Alternative A; Connection to Public Sewer Extension of Public Sewer=> PV= $5,182,112 2. Alternative B; Land Applications Subsurface Drip System=> PV= S114,332 Surface Drip System=> PV=S179,258 3. Alternative C; Wastewater Reuse Wastewater Reuse System=> PV= S391,486 4. Alternative D; Direct Discharge to Surface Waters. Direct Discharge System=> PV=$32,624 If there are any questions related to this Engineering Alternative Analysis(EAA),please contact: Engineer Owner Michael Lash,PE Richard Beck Lash Engineering,Inc. Residential 1104 Cindy Carr Drive 2656 Findlay Avenue Matthews,NC. 28105 Palm Bay,Fl. 32908 Ph: 704-847-3031 Contact: 585-746-1515 Email: mikel@a,lashengineering.com Email:rbeck001@rochester.rr.com EAA Page 21 Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews,NC 28105 Phone: 704-847-3031 mikel@LashEngineering.com Lash Engineering, Inc. TABLE OF CONTENTS • Watershed & Information 1. Table of Contents 2. NC Surface Water Classification Report 3. NC Residential StreamStats Report with Watershed 4. Full FIRM Floodway Map 5. USGS Map NC ShootingCreek 6. Results of USGS Low Flow analysis 7. Endangered Species Report 8. Endangered Species Report Fee Watershed&Add Info Page 1 Surface Water Classifications: Stream Index: 1-21-7 Stream Name: Compass Creek Description: From source to Tusquitee Creek Classification: C;Tr,HQW Date of Class.: July 31 1990 What does this More info Class. mean? River Basin: Hiwassee Watershed&Add Info Page 2 Beck StreamStats Report Region ID: NC Workspace ID: NC20220122220307275000 Clicked Point (Latitude, Longitude): 35.08964, -83.72041 Time: 2022-01-22 17:03:25 -0500 • 44,‘ 1. • r_ Basin Characteristics Parameter Code Parameter Description Value Unit BSLDEM30FT Mean basin slope, based on slope percent grid 59 percent BASINPERIM Perimeter of the drainage basin as defined in SIR 2004-5262 12.1 miles CSL10_85fm Change in elevation between points 10 and 85 percent of length along 582.24 feet main channel to basin divide divided by length between points ft per per mi mi DRNAREA Area that drains to a point on a stream 3.17 square miles ELEV Mean Basin Elevation 3560 feet LC01 WATER Percentage of open water, class 11, from NLCD 2001 0 percent LCO1WETLND Percentage of wetlands, classes 90 and 95, from NLCD 2001 0 percent Watershed&Add Info Page 3 PROTECTED Percent of area of protected Federal and State owned land 1 percent Parameter Code Parameter Description Value Unit SSURGOA Percentage of area of Hydrologic Soil Type A from SSURGO 20.4 percent SSURGOB Percentage of area of Hydrologic Soil Type B from SSURGO 74.8 percent SSURGOC Percentage of area of Hydrologic Soil Type C from SSURGO 3.8 percent SSURGOD Percentage of area of Hydrologic Soil Type D from SSURGO 1 percent USGS Data Disclaimer: Unless otherwise stated,all data,metadata and related materials are considered to satisfy the quality standards relative to the purpose for which the data were collected.Although these data and associated metadata have been reviewed for accuracy and completeness and approved for release by the U.S.Geological Survey(USGS),no warranty expressed or implied is made regarding the display or utility of the data for other purposes,nor on all computer systems,nor shall the act of distribution constitute any such warranty. USGS Software Disclaimer:This software has been approved for release by the U.S.Geological Survey(USGS).Although the software has been subjected to rigorous review,the USGS reserves the right to update the software as needed pursuant to further analysis and review. No warranty,expressed or implied,is made by the USGS or the U.S.Government as to the functionality of the software and related material nor shall the fact of release constitute any such warranty. Furthermore,the software is released on condition that neither the USGS nor the U.S.Government shall be held liable for any damages resulting from its authorized or unauthorized use. USGS Product Names Disclaimer:Any use of trade,firm,or product names is for descriptive purposes only and does not imply ndorsement by the U.S.Government. Application Version:4.6.2 StreamStats Services Version: 1.2.22 NSS Services Version: 2.1.2 Watershed&Add Info Page 4 Nation Flood Hazard Layer FI RMette `� FEMA Legend 83°43'32"W 35°5'38"N _.. .. SEE EIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT _ .111(111 Without Base Flood Elevation(BFE) Tone A.V.499 SPECIAL FLOOD With BFE or Depth Zone AE,A0,AN,FE,AR * • HAZARD AREAS Regulatory Floodway ; iio VI w • 0.2%Annual Chance Flood Hazard,Areas of 1%annual chance flood with average Not v depth less than one foot or with drainage areas of less than one square mile �*` Future Conditions 1%Annual 1 Chance Flood Hazard :one?. * Area with Reduced Flood Risk due to r x Levee.See Notes.zone x .. a OTHER AREAS OF 0 FLOOD HAZARD Area with Flood Risk due to Leveezone o IllrNO SCREEN Area of Minimal Flood Hazard Zonex r1 Effective L0MRs Ilk R OTHER AREAS Area of Undetermined Flood Hazard 'ne0 d AREA OF MINIMAL FLOOD HAZARD M GENERAL -—-- Channel,Culvert,or Storm Sewer • s- W` STRUCTURES I I i I I I I Levee,Dike,or Floodwall r 4 e ZDPX - k iti r - r Cross Sections with 1%Annual Chance e rp ' ilk °` 1T8 Water Surface Elevation a .III► .. ., • y e— — — Coastal Transect / V3---- Base Flood Elevation Line(BFE) ../0-" , Limit of Study Jurisdiction Boundary el' w:& . --- Coastal Transect Baseline OTHER _ Profile Baseline FEATURES 4 (, Hydrographic Feature I ,, i r 44,... 13,�"'-"�-,� � Digital Data Available N ego EI No Digital Data Available MAP PANELS ® Unmapped "� Q r _ The pin displayed on the map is an approximate �'' point selected by the user and does not represent w411 V" iti w �1 an authoritative property location. .4 - T. -` q O� `/ This map complies with FEMA's standards for the use of oir- y a �— p digital flood maps if it is not void as described below. D © T� -- 'r �� The basemap shown complies with FEMA's basemap n r ,�"'...one AE v� ��1" N..1 4` s accuracy standards r-' t '" The flood hazard information is derived directly from the ,, 18 u �� �. authoritative NFHL web services provided by FEMA.This map P �.,.�r�r�'w s was exported on 5/10/2022 at 6.23 PM and does not ,^;,rrMsl r� 'oil w` ,R reflect changes or amendments subsequent to this date and aw'- * _-- (� / time.The NFHL and effective information may change or r „// ' 4 become superseded by new data over time. r j . f �. R This map image is void if the one or more of the following map f_ ,n , elements do not appear:basemap imagery,flood zone labels, �(1 - fir-1% 1-- �\ f. µ legend,scale bar,map creation date,community Identifiers, 83°42'S4"W 35°5'8"N FIRM panel number.and FIRM effective date.Map images for Feet 1•6 00o unmapped and unmodernized areas cannot be used for 0 250 500 1,000 1,500 2,000 regulatory purposes. Basemap:USGS National Map:Ortholmagery:Data refreshed October,2020 E = _ b 8 E E Y E & 9 ■ S Fll \ , / i �r C r Ili Cq i III! HIN th'lIt(t .. \' .\' ' .k er7-1-------*---yy-- 5 �{t6eft 6 f'4 '.7 ki :C `D` IIr( P ( c^`: V� �Itiil III`III 4 . ;` ttt� _ =. c.r ; ` $.bo u>it — i " icy r.�� �^ • � ; —� r 4 1-"77S441,`I :''''`N-,t, ,„,re- 01 - \V° • '--- ' ,----A a , ,,,, "'^i i--. .----0,---- ---c„,--- ,_..„ ) - (I �) ;!;),- t a g"1� ~ ---- .�+,A,,,.,,,....., 1 4.rn ' _ i „1 , ,,,.....,„,, .,... a f o'., �,5,-{ r- l v T. f -,- S w:fl r IL. vim. 00".." , ` AA- ;''''''‘'' ' - il 111 d . "/a°, �.,:� 1 / (= g am,.��<c ,„,S Y _, 'v ids ,�� y\'^-) \v Cklfq ,-;---)-.-,'-_,.;-\,l\ , ram- ,< ' , Y � � �. O1 / O �� F 1��� '� li r,' ! L,��� Z u' I� bl J �� 0 � _ l: / � ,. '�7//i,,. t�. o �1. Il r `! „,)J �1���!119 �•11�--,..:-.. .)1 i ) L.',,{,... _ IS'N, .."7.-Ro to 3,(A ii„,„).-f,,It 10..,-.A,.„-,---.. ..4,,,avit'7�" I ``� �,�' ,rAl: i0:1 Jr � /*, � (13 ,Z `-,,.a .tf�« Y fit , ���)�«;lv�n ,�� -� i k ll,--r,,�fl� )} „f/.,� ,i, Lam, ^�w/�Ir�� �rl �� ��r�� ui �1" �' (ptA (re, f t.. t - )-----'lam t , ( r,` Z l �� , 1---,, �,�� Y C `'1 ,�l ( � �LZ�3SctCc,��� fS l4 _..a • �, _ 7 f t =, g If t � i ►�a 1 _� �����}� til f{i a { _ �r�/ 4(�� l a� �5��� l�L07 _ //C tit L ` co)i a ))/ L----, \ i;.(,44 .----,.--,,,•,. .,:s(t,i...7.,._,.____. 8 E€ e {. Rr. ]}� `� ti t s E[ ` 1� `��111`� "`• \`, b ��1L` f`j / 7 t � ` �"" u -,,,,„.,..* ,„„,,,.. _.... € 1 ti t } Q ai `� -'', if.,„ .„ a , �4�j�� f' ii '' m s 8 i' Fi:= `! 1 (\ ., . .? r'/ ��)j �• _ r ;� /�--) ;�/�Gr r ((l4. ° m E E Y,,i �E 8 Y S 8Y� i 3 i Firefox https://outlook.office365.com/mail/deeplink?popoutv2=1&version=202... USGS response to DWR USGS Low Flows request # 2021-113 (dated 2021/03/17) for Cane Branch Yancey County...RE: [EXTERNAL] Low-flow request approval Weaver, John C <jcweaver@usgs.gov> Thu 3/18/2021 5:25 PM To: Michael Lash <mikel@lashengineering.com> Cc: Hill, David A <david.hill@ncdenr.gov>;adugna.kebede@ncdenr.gov <adugna.kebede@ncdenr.gov>;Montebello, Michael 1 <Michael.Montebello@ncdenr.gov>;Albertin, Klaus P <klaus.albertin@ncdenr.gov>;Weaver,John C <jcweaver@usgs.gov> Mr. Lash, In response to your inquiry about the low-flow characteristics for a location on Cane Branch adjacent to Cane Branch Road (SecondaryRoad 1146) in the vicinityof Micaville in east central YanceyCounty,the following information is provided: A check of the low-flow files here at the USGS South Atlantic Water Science Center(Raleigh office) does not indicate a previous low-flow determination for the point of interest, identified by the lat/long coordinates (35.89221, -82.23696) provided via email dated 03/17/2021 from the DWR USGS Low Flow portal following your request submission. No USGS discharge records are likewise known to exist for the point of interest. In the absence of site-specific discharge records sufficient for a low-flow analysis, estimates of low- flow characteristics at ungaged locations are determined by assessing a range in the low-flow yields (expressed as flow per square mile drainage area, or cfsm) at nearby sites where estimates have been determined. A basin delineation completed using the online USGS StreamStats application for North Carolina (https://streamstats.usgs.gov/ss/) indicates the drainage area for the point of interest (StreamStats adjusted coordinates 35.89222, -82.23689 NAD83) is 0.57 sqmi. For streams in Yancey County,low-flow characteristics published by the USGS are provided in the following reports: (1)The first is a statewide report completed in the early 1990's. It is USGS Water-Supply Paper 2403, "Low- flow characteristics of streams in North Carolina" (Giese and Mason, 1993). An online version of the report is available at https://pubs.usgs.gov/wsp/2403/report.pdf. The report provides the low-flow characteristics (based on data through 1988)via regional relations and at-site values for sites with drainage basins between 1 and 400 sqmi and not considered or known to be affected by regulation and/or diversions. (2)The second is a statewide report published in March 2015. It is USGS Scientific Investigations Report 2015-5001, "Low-flow characteristics and flow-duration statistics for selected USGS continuous-record streamgaging stations in North Carolina through 2012" (Weaver, 2015). The report is available online at hops://pubs.usgs.gov/sir/2015/5001/. The report provides updated low-flow characteristics and flow- duration statistics for 266 active (as of 2012 water year)and discontinued streamgages across the state where a minimum of 10 climatic years discharge records were available for flow analyses. Low-flow characteristics estimated for point of interest: Watershed&Add Info Page 7 1 of 4 3/19/2021,7:36 AM Firefox https://outlook.office365.com/mail/deeplink?popoutv2=I&version=202... Inspection of the reports indicates the presence of eight(8) nearby selected USGS partial-record sites(5)and continuous-record streamgages(3) in the general vicinity of the point of interest where low-flow characteristics were published. Among these 8 index sites,the low-flow discharge yields for the indicated flow statistics are as follows: Annual 7Q10 low-flow yields=_>from 0.23 to 0.52 cfsm (average about 0.36 cfsm, median about 0.33 cfsm) Annual 30Q2 low-flow yields==>from 0.45 to 1 cfsm (average about 0.73 cfsm, median about 0.76 cfsm) Winter 7Q10 low-flow yields==>from 0.29 to 0.7 cfsm (average about 0.5 cfsm, median about 0.52 cfsm) Annual 7Q2 low-flow yields==>from 0.36 to 0.78 cfsm (average about 0.58 cfsm, median about 0.6 cfsm) Average annual discharge yields==>from 1.8 to 3.4 cfsm (both average and median about 2.6 cfsm) for Application of the above range in yieldsthe to the drainage area (0.57 sqmi) t e point of interest results in the following estimated low-flow discharges: Annual 7Q10 low-flow discharges==>from 0.13 to 0.3 cfs (average about 0.21 cfs, median about 0.19 cfs) Annual 30Q2 low-flow discharges==>from 0.26 to 0.57 cfs(average about 0.42 cfs, median about 0.43 cfs) Winter 7Q10 low-flow discharges==>from 0.17 to 0.4 cfs (average about 0.29 cfs, median about 0.3 cfs) Annual 7Q2 low-flow discharges==>from 0.21 to 0.44 cfs (average about 0.33 cfs, median about 0.34 cfs) Average annual discharge discharges==>from 1 to 1.9 cfs(both average and median about 1.5 cfs) Please note: (1)The estimated flows are provided in units of cubic feet per second (cfs). (2)The low-flow yields provided above are rounded to 2 significant figures. Estimated low-flow discharges less than 1 cfs are rounded to 2 significant figures. If between 1 and 100 cfs,then rounded to 1 decimal place; if greater than 100,then rounded to the nearest whole number(zero decimal places). (3)The information provided in this message is based on a preliminary assessment and considered provisional,subject to revision pending collection of future data and further analyses. These provisional streamflow statistics are provided via the DWR USGS Low Flows cooperative agreement between the USGS and the N.C. Department of Environmental Quality, Division of Water Resources. Hope this information is helpful. Thank you. Curtis Weaver J.Curtis Weaver,Hydrologist, PE Email:jcweaver@usgs.gov USGS South Atlantic Water Science Center Online:https://www.usgs.gov/centers/sa-water North Carolina-South Carolina-Georgia 3916 Sunset Ridge Road Raleigh,NC 27607 Phone:(919)571-4043 // Fax:(919)571-4041 Watershed&Add Info Page 8 2 of 4 3/19/2021,7:36 AM Firefox https://outlook.office365.com/mail/deeplink?popoutv2=1&version=202... From:Albertin, Klaus P<klaus.albertin@ncdenr.gov> Sent:Wednesday, March 17, 2021 1:32 PM To: mike) lashen ineerin .com g g Cc:Albertin, Klaus P<klaus.albertin@ncdenr.gov>; Hill, David A<david.hill@ncdenr.gov>; adugna.kebede@ncdenr.gov;Weaver,John C<jcweaver@usgs.gov>; Montebello, Michael J <Michael.Montebello@ncdenr.gov> Subject: [EXTERNAL] Low-flow request approval This email has been received from outside of DOI-Use caution before clicking on links,opening attachments,or responding. Your request has been approved and will be forwarded to USGS. A response from USGS usually takes 7 - 10 business days. Request Flow Statistic Approval Request ID: 113 Requestor: Michael Lash, PE. - Lash Engineering, Inc. Requestor e-mail: mikel@lashengineering.com Requestor Phone: 704-847-3031 Local Government: Public Water Supply: Consultant: Lash Engineering, Inc. Contact: Michael Lash Reason: Permit River/Stream: Cane Branch Drainage Area (sq. mi.): 0.66 sq.mi. Latitude: 35.89221 Longitude: -82.23696 Watershed&Add Info Page 9 3 of 4 3/19/2021,7:36 AM Firefox https://outlook.office365.com/mail/deeplink?popoutv2=1&version=202... Other Information: 1489 Cane Branch Road, Burnsville, NC. - parcel is small with 2 structures. North structure is the house. Statististics: ["7Q10","30Q2'} Approved by: Albertin, Klaus P Watershed&Add Info Page 10 4 of 4 3/19/2021,7:36 AM Roy Cooper,Governor a •al NC DEPARTMENT OF D.Reid Wilson,Secretary NATURAL AND CULTURAL RESOURCES Misty Buchanan 1 Deputy Director,Natural Heritage Program NCNHDE-18118 May 30, 2022 Michael Lash Lash Engineering, Inc. 1104 Cindy Carr Drive Matthews, NC 28105 RE: Beck Wastewater Direct Discharge Dear Michael Lash: The North Carolina Natural Heritage Program (NCNHP) appreciates the opportunity to provide information about natural heritage resources for the project referenced above. A query of the NCNHP database indicates that there are records for rare species, important natural communities, natural areas, and/or conservation/managed areas within the proposed project boundary. These results are presented in the attached 'Documented Occurrences' tables and map. The attached 'Potential Occurrences' table summarizes rare species and natural communities that have been documented within a one-mile radius of the property boundary. The proximity of these records suggests that these natural heritage elements may potentially be present in the project area if suitable habitat exists. Tables of natural areas and conservation/managed areas within a one-mile radius of the project area, if any, are also included in this report. If a Federally-listed species is documented within the project area or indicated within a one-mile radius of the project area, the NCNHP recommends contacting the US Fish and Wildlife Service (USFWS) for guidance. Contact information for USFWS offices in North Carolina is found here: httos://www.fws.gov/offices/Di rectory/ListOffices.cfm?statecode=37. Please note that natural heritage element data are maintained for the purposes of conservation planning, project review, and scientific research, and are not intended for use as the primary criteria for regulatory decisions. Information provided by the NCNHP database may not be published without prior written notification to the NCNHP, and the NCNHP must be credited as an information source in these publications. Maps of NCNHP data may not be redistributed without permission. Also please note that the NC Natural Heritage Program may follow this letter with additional correspondence if a Dedicated Nature Preserve, Registered Heritage Area, Land and Water Fund easement, or an occurrence of a Federally-listed species is documented near the project area. If you have questions regarding the information provided in this letter or need additional assistance, please contact Rodney A. Butler at rodney.butler@ncdcr.gov or 919-707-8603. Sincerely, NC Natural Heritage Program DEPARTMENT OF NATURAL AND CULTURAL RESOURCES 1 121 W Jti?NES',MEET.RALEIC,H.NC 27€70 • Ifi51 MAIL SERVICE CENTER.PAL: ICJ OFC',.! 7 ' • FAX`1 7r;7,-4;?; Watershed&Add Info Page 11 Natural Heritage Element Occurrences, Natural Areas, and Managed Areas Intersecting the Project Area Beck Wastewater Direct Discharge May 30, 2022 NCNHDE-18118 Element Occurrences Documented Within Project Area Taxonomic EO ID Scientific Name Common Name Last Element Accuracy Federal State Global State Group Observation Occurrence Status Status Rank Rank Date Rank Crustacean 24105 Cambarus parrishi Hiwassee Headwaters 2019-08-08 E 3-Medium --- Special G2 Si Crayfish Concern Natural Areas Documented Within Project Area Site Name Representational Rating Collective Rating HIW/Upper Hiwassee River Aquatic Habitat R1 (Exceptional) C2 (Very High) No Managed Areas Documented within the Project Area Definitions and an explanation of status designations and codes can be found at httos://ncnhde.natureserve.org/helo.Data query generated on May 30,2022;source:NCNHP,Q1,April 2022.Please resubmit your information request if more than one year elapses before project initiation as new information is continually added to the NCNHP database. I Page 2 of 4 Natural Heritage Element Occurrences, Natural Areas, and Managed Areas Within a One-mile Radius of the Project Area Beck Wastewater Direct Discharge May 30, 2022 NCNHDE-18118 Element Occurrences Documented Within a One-mile Radius of the Project Area Taxonomic EO ID Scientific Name Common Name Last Element Accuracy Federal State Global State Group Observation Occurrence Status Status Rank Rank Date Rank Amphibian 38943 Cryptobranchus Eastern Hellbender 2017-07-12 E 3-Medium --- Special G3T2 S3 alleganiensis Concern alleganiensis Crustacean 33801 Cambarus Valley River Crayfish 2019-08-08 E 3-Medium --- Significantly G3G4 S2 brimleyorum Rare Crustacean 24105 Cambarus parrishi Hiwassee Headwaters 2019-08-08 E 3-Medium --- Special G2 S1 Crayfish Concern Dragonfly or 33719 Somatochlora elongataSki-tipped Emerald 2004-Pre H? 5-Very --- Significantly G5 S2 Damselfly Low Rare Vascular Plant 23931 Hackelia virginiana Virginia Stickseed 1968-Pre H 5-Very --- Significantly G5 S2 Low Rare Peripheral Natural Areas Documented Within a One-mile Radius of the Project Area Site Name : . Representational Rating Collective'Rating HIW/Upper Hiwassee River Aquatic Habitat R1 (Exceptional) C2 (Very High) Managed Areas Documented Within a One-mile Radius of the Project Area Nantahala National Forest - Tusquitee Ranger US Forest Service Federal District Definitions and an explanation of status designations and codes can be found at httos://ncnhde.natureserve.org/help.Data query generated on May 30,2022;source:NCNHP,Ql,April 2022.Please rksubmit your information request if more than one year elapses before project initiation as new information is continually added to the NCNHP database. CD CD a 90 n n 5 0 CD CD w Page 3 of 4 NCNHDE-18118: Beck Wastewater Direct Discharge ` t, t, ra 1'v. USCI1 11a R.ti / N N,, ; X WL 0 0.25 05 1 Miles co (; S — — I I I 1 I I I I J m May 30.2022 Q, Managed Area(MAREA) n NHP Natural Area(NHNA) Buffered Project Bounds Sources Esn Airbus DS USGS NGA NASA.CGIAR.N Roonson lit E.SS Boundary NLS. OS. NMA Geodatastyretsen Rijkswaterstaat GSA. Geoiand FEMA Intermap and the GIS user community 0 Project Boundary Sourcescontributors and the GE GarmIn FAO TS User Cammun. NOAA USGS OpenStreetMap (0 (D .A Page 4 of 4 NC Natural Heritage Program: Payment: Receipt https://checkout.globalgatewaye4.firstdata.com/payment/final_receipt?m... NC Natural Heritage Program Your Order Print This Page Quantity Item Unit Price Id: NCNHDE-18118 Title: Beck Wastewater Direct 1 $100.00 USD 100.00 Discharge Project Type: Other Total USD 100.00 This order is now complete. Transaction approved! Here is your receipt: TRANSACTION RECORD NC NATURAL HERITAGE PROG 121 W JONES ST RALEIGH, NC 27699 United States WWW.NCNHP.ORG TYPE: Pre-Authorization ACCT: Visa $ 100.00 USD CARDHOLDER NAME : Michael Lash CARD NUMBER : ############7121 DATE/TIME : 30 May 22 18:24:44 REFERENCE # : 001 0244830 M AUTHOR. # : 351718 TRANS. REF. : 1066 Approved - Thank You 100 Please retain this copy for your records. Cardholder will pay above amount to card issuer pursuant to cardholder agreement. NC Natural Heritage Program Secure Payment provided by First Data Corp. Watershed&Add Info Page 15 1 of 1 5/30/2022,6:25 PM _ , , • , : Lash Engineering, Inc. E Civil/Consulting/Wastewater/Planning , , 1104 Cindy Carr Drive Matthews,NC 28105 Phone: 704-847-3031 mi ke I na,Lash Engineering.com Lash Engineering, Inc. TABLE OF CONTENTS Operation & Maintenance 1. Table of Contents 2. Operator Checklist— Engineer Supplied for Direct Discharge 3. AquaSafe Brochure 4. AquaSafe Septic &Aerobic 5. AquaSafe Cut-Away 6. AquaSafe Operation & Maintenance 7. AquaSafe UV Installation & Maintenance 8. AquaSafe UV Light Letter 9. AS1100L EZ with UV Post Aeration 10. UV-TUD Bulb Efficiency O&M Page 1 OPERATOR CHECK-LIST INSPECTION OF ENGINEERED WASTEWATER SYSTEMS Operator Company Name of Establishment Permit/Project No. Location Type of Establishment Design Flow Owner/Agent Address Phone Operator's Name Address Phone Date, Purpose of Inspection & Remarks Yes No REMARKS 1. ESTABLISHMENT: Type, size, and sewage flow in accordance with permit? 2. COLLECTION SYSTEM: No evidence of leaks into or out from sewer lines/manholes? Free of blockages/solids buildup in lines or manholes? Manholes/Clean-outs: visible, maintained, &at grade? 3. OVERALL GENERAL CONDITION: Structurally sound, protected from corrosion, watertight? Floats/pipes/valves/disconnects in good working condition? Grounds maintained in a safe, sanitary condition? Control panel enclosures/components in good condition? Facility meeting flow and quality limits? 4. TANKAGE (Grease Traps/Lift Stations/Septic/Dosing Tanks): Tank risers accessible and surface water diverted Tanks and access manholes structurally sound, watertight? Sanitary tee(s) in good working condition Tanks pumped, cleaned out as needed? Surface water being effectively diverted away? 5. EFFLUENT DOSING SYSTEM: Effluent appears clear, free of excess solids? _ PUMP SYSTEMS: Required pumps present, operating, and cycling properly? High-water alarm present and operating properly? Floats/pipe/valves/disconnects in good working condition? Control panel enclosure/components in good condition? Elapsed time readings: 7. HEADWORKS: Interior clean, free of debris, adjusted to grade? Valves operational, Filters functional, Flow Meter _ Working, Pressure Gauges functional? Timed doses at required time. Control Panel operating Zones properly. 8. UV SYSTEM: Working, operating and maintained properly? UV Light working properly? _ O&M Page 2 Yes No REMARKS 9. FLOW MONITORING DEVICE: Present and in good working condition-if required? 10. EFFLUENT DOSING TANK: Effluent appears clear, free of suspended solids? Required pumps present, operating and cycling properly? High-water alarm present and operating properly? _ Elapsed time readings: 11. Force Main & Discharge: No evidence of effluent surfacing/reaching surface waters Diversions/ditches/swales/tile drains properly maintained? Line cover/vegetation maintained as needed? Clean outs of discharge pipe are adjusted and vertical? Discharge location showing signs of erosion or sediment? Discharge pipe is free of debris &open? OVERALL CONDITION AND OPERATION OF SYSTEM: SUMMARY OF IMPROVEMENTS NEEDED: Improvements Repair Within (Days) DATE: SIGNED: AGENT O&M Page 3 s . - --.i. ',.. . . -46 , '-- - Wrallill rill4:11111114 . .„ % ,,_:;,,_, .. ' . . :- :', f;: ' . '''''. '''''. .. ' , ' ' ::'''. ' . ' r . , ,. . , . . . ...„, _ , ,, _ ,_ . , : _._ _ ,,, .., ._,..„....,...„ ..:, ,, . __. .,_„...,.., ___T,.,., . „ ,, „,..„, - series o 1 Advanced Aero 1 ic TreanSy as A'A ccess & Maintenance -, - of Components • b. 1 . A�-c �fidy j; ,, AS 50E1 I, AIJA 4):: . 4 r Short Height 5ft. Easy Install v , _`° r'- MANUFACTURED B • Y' OLOGICAL TANKS 247 HW1'1'. 151 N. •• DOWNSV Il LE,1 4 7_ _ .��qqus Patera ticm ea: •:�51%iit 96D4236386.666: 1-800-277-8179 . Other Patents Pending www.etiaquasafe.com • aquasafe(kbayo ,,:i,.,. , A RISER ACCESS COVER Q �[YTOR COV[R r AVIATOR RR } cG oISER r< b/ 79" ).1 5y' A 6" 8.5" O LL C < D to 0 W < -n 0 rn < 72" > 60" • 9" 10" J � TOP VIEW NOTES: Total Tank Volume: 908 Gallons to flow line LIMITED WARRANTY Ecological Tanks,Inc.,Aqua Safe„(hereinafter identified as manufacturer)warrants each Aqua Safe€wastewater treatment plant to the original purchaser only to be free from defects in materials and workmanship from the date of installation by an authorized dealer/installer for the following periods:Manufacturer warrants system aerator for a limited.prorated five(5)year period as follows:First two(2)years- 100%:2nd to 3rd year-75%: 3rd to 4th year-50%;and 4th to 5th year-25%of list price. Third.fourth and fifth year limited.prorated portion of this warranty applies only if the system owner carries a continuous maintenance policy provided by a manufacturer authorized dealer/installer and proof thereof is provided with the return.Aerators on Models AS750,AS800,AS1000,AS1100 and AS1500 are warranted for two(2)years. Manufacturer warrants fiberglass tanks.for a limited period of five(5)years.to be free from defects in material and workmanship. Electrical controls.float switches and application pumps are warranted for two(2)years. Concrete tanks are limited to two(2)years from date of installation.When properly installed and registered with the manufacturer.the manufacturer's sole obligation under this limited warranty is as follows: To repair or exchange any components.F.O.B.factory.that in the manufacturer's judgment is defective.provided that said component part has been paid for and is returned through an authorized dealer.prepaid. The warrantee must specify the nature of the defect in writing to the manufacturer. The limited warranty makes no provision for any informal dispute settlement agreement. The limited warranty does not cover any Aqua Safe„wastewater treatment plant that has not been properly installed.damaged due to altered installation or improper wiring or overload protection.flooded by any external means.disassembled by any unauthorized person.filled with anything other than normal household wastewater or damaged by an act of nature. The limited warranty does not cover damages or defects caused by ants. insects or rodents to any component part of the Aqua Safe,wastewater treatment plant. No warranty is made as to the field performance of any system. The limited warranty applies only to the Aqua Safe,wastewater treatment plant itself and does not include any of the purchaser's plumbing.drainage and/or disposal system.house wiring or the installation of the Aqua Safe, treatment plant. The manufacturer reserves the right to replace any component part covered under this limited warranty with a component part.which in the • judgment is equivalent to thepart beingreplaced. The manufacturer claims no responsibility for any delays or damages caused by manufacturer's1u L q defective components or materia ls is which cause losses incurred by interruption of service or for repairs or replacements of component parts covered by the limited warranty. Distributed By O&M Page 5 7 ' I( )1 .., A . .,, ., . ..: , . .. . .. . ,,. , ,,,..,:. . , 4 „.... . . ... ,., ,.-,,„0. ,;;_. ._,: ,,,...:,% ....;,... .•.. :,. : , ..__..„,,,._:,.,..,„:„,,_. ,. ,.„,,,,,...,., .„: ,..a,...,_:.,, ..,„ ,. 4-, :. 4;-- .. ' v.. , ....,...,.„ , „..,. „ -,: `,Nitro en Reduction series of A vanced Aerobic Treatment Units _ .i..,,. _ ' ,.,. ,.. .._:. , 0 ,, _____ , __.:„__:-_-_._:--------.„ rt, . ......._ . _____ ___ ., . . _______:___ , :_--------..: . -,-.,„.. ....,,•:- . ,,......_,. ,. . .....,._ ,..., _... ,. __ _....,___ _ . ... „...._ __ _.,. ..: _ • ..:„...„,„, _.,„,..„ .. _ .. , . ...... ... . ., . .„ ...„, ... ...„ ••• •.,,, ra. .. • , ._ nk - " --- ,..,•: - ,.- . . ._. S6i00 +4.KR AQUA 4 SAFE \1ANUFAC TLJRE() BY STANDARD ECOLOGICAL TANKS INC. U.S.Patent Numbers, 4 `� 2247 HWY. 151 N. • UO��NSVILLE,LA 712345,549,818;6,096.203;D426,866; QQ �7�/ Q �J D424,659;D423,638;D539,382 STANDARD I-OOO-Z/ /�$I /9 O&M t g e®ts Pending 245 vkNv .etiaquasafe.com • aquasafe(a bayou.com Ecological Tanks, I .nc Aqua Safe NR series dimensions 124.5' -- - —, ti__�h _ o �Esso`a / vF]:T 27' e - ; F19PANEASS tt ll ' .^'. 1 PANEL 15 x,... 7 4a III -, g]/ P��Ra: 1 �'A'ItT y PVGPO...EY .. qp p • 4'OVfILT 1e \ s GAL5 \'MANE / 0 24 ' P UNK, 1 D GALL[N 1: \ I9k.\nMTT TAI:K. / •r +��+ fM nPD:e �i • 24' I 76 70 48'Center.i 66' CenteUn e / •:- f_ 9' PANE I. TOP VIEW AE9Anon�OEU E mod" ,. era c.vs. \ ..J cti 28' ^� H �gJ H 1 1 / \ / *AS600NR series include both 400 or 500 gallon pre-tanks as approved models. LIMITED WARRANTY Ecological Tanks,Inc.,Aqua Safe*(hereinafter identified as manufacturer)warrants each Aqua Safe*wastewater treatment plant to the original purchaser only to be free from defects in materials and workmanship from the date of installation by an authorized dealer/installer for the following periods:Manufacturer warrants system aerator for a limited,prorated five(5)year period as follows:First two(2)years-100%;2nd to 3rd year-75%; 3rd to 4th year-50%;and 4th to 5th year-25%of list price. Third,fourth and fifth year limited,prorated portion of this warranty applies only if the system owner carries a continuous maintenance policy provided by a manufacturer authorized dealer/installer and proof thereof is provided with the return.Aerators on Models AS750,AS800,ASI000,AS1100 and AS1500 are warranted for two(2)years. Manufacturer warrants fiberglass tanks,for a limited period of five(5)years,to be free from defects in material and workmanship. Electrical controls,float switches and application pumps are warranted for two(2)years. Concrete tanks are limited to two(2)years from date of installation.When properly installed and registered with the manufacturer,the manufacturer's sole obligation under this limited warranty is as follows: To repair or exchange any components,F.O.B.factory,that in the manufacturer's judgment is defective,provided that said component part has been paid for and is returned through an authorized dealer,prepaid. The warrantee must specify the nature of the defect in writing to the manufacturer. The limited warranty makes no provision for any informal dispute settlement agreement. The limited warranty does not cover any Aqua Safe®wastewater treatment plant that has not been properly installed,damaged due to altered installation or improper wiring or overload protection,flooded by any external means,disassembled by any unauthorized person,filled with anything other than normal household wastewater or damaged by an act of nature. The limited warranty does not cover damages or defects caused by ants. insects or rodents to any component part of the Aqua Safes wastewater treatment plant. No warranty is made as to the field performance of any system. The limited warranty applies only to the Aqua Safe*,wastewater treatment plant itself and does not include any of the purchaser's plumbing,drainage and/or disposal system,house wiring or the installation of the Aqua Safe,_; treatment plant. The manufacturer reserves the right to replace any component part covered under this limited warranty with a component part,which in the ' manufacturer's judgment is equivalent to the part being replaced. The manufacturer claims no responsibility for any delays or damages caused by defective components or materials which cause losses incurred by interruption of service or for repairs or replacements of component parts covered by the limited warranty. Distributed By t A - >f O&M Page 7 i C+. ,„, ,; R ,_ ,,,,,,,,,. Design maximizes owner's benefit and minimizes installer's labor & t installation costs Design uses versatile top-of-the-line ~` parts for simplicity and , adaptability for the onsite installer x pu Design includes all-in-one multi-tank . : 4' configurations with one-box controls for pumps, aerators, and k' y` `� � other accessories Diffusers never have to be cleaned 7 ECOLOGICAL TANKS, INC. AQUA i SAFE ® "The standard by which the performance of other units is compared"® Class I Wastewater Treatment Plants Installation, Operation, Maintenance and Trouble-Shooting Manual for Distributors, Installers, and Maintenance Providers MODELS AS500 AS600 AS750 AS1000 AS1500 ,S500EZ AS600EZ AS750EZ AS1000EZ AS1500EZ AS500-CU AS600-CU AS500-3DUO AS600-3DUO AS500-P5CU AS500+5DUO AS500+5PRE AS500-4+75 AS500+5TRIO AS500+75TRIO "Copyright Notice" No part of this publication may be reproduced, stored in any retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise without the prior written permission of Ecological Tanks, Inc. Mfg. By r --- . Ecological Tanks, Inc. 2247 Hwy 151 North NSF Downsville, LA 71234 ..___y PH (318) 644-0397 * FAX (318) 644-7257 Certified to NSF/ANSI Standard 40 O&M Page 9 ©2007 I. INTRODUCTION Ecological Tanks,Inc.was founded in 1994 by people with combined experience in installation, pre-casting and the building industry. At Ecological Tanks, Inc. our main goal is to provide products to professionals engaging in the business of distributing, installing and servicing home wastewater treatment plants. To continue our service,we have dedicated ourselves to manufacturing versatile products to simplify the task of installation and maintenance. This will include all-in-one aerobic systems,the first one box control for the operation of pumps and compressors, unique up- size controls and other products that are first in the on-site sewage industry. With this unique diversity and know how, we can provide the help you need with your on-site sewage treatment business. Ecological Tanks,Inc.Model AS500,and larger,wastewater treatment plants have been tested by Baylor University Department of Environmental Studies according to requirements listed in NSF/ANSI Standard 40 and meets or exceeds Class 1 plant characteristic requirements. Some states require the use of a trash trap independent of this test. Ecological Tanks, Inc. recommends strongly the use of a trash trap or pre-treatment tank, especially in all cases where a garbage disposal is being used or may be used. Additionally, Ecological Tanks, Inc. strongly recommends the use of a trash trap when using sprinklers, drip systems, or pressure dosing as a means of effluent disposal. A minimum recommended size for a trash trap is one-half the daily rated capacity of the unit. This recommendation enables enough capacity to store non-biodegradable materials over an extended period of time (several years)to minimize pumping requirements and overall maintenance on sprinkler,drip and dosing effluent disposal systems. This size is also small enough not tQ interfere substantially with the aerobic performance of the unit or to raise cost excessively. For purposes of the unit certification,a trash trap is treated as an approved upgrade. II. AQUA SAFE®WASTEWATER TREATMENT PLANT PROCESS DESCRIPTION Aqua Safe® series models of wastewater treatment plants are made with an outer mixing compartment and a center settling or clarifier compartment. They are in many ways similar to large township or municipality sewage treatment plants. They employ an extended aeration, activated sludge process. This type of treatment depends primarily upon the use of air that is introduced by air passing from the aerator compressor to four air lines located around the perimeter of the aeration mixing compartment. As wastewater enters the aeration mixing compartment simple hydraulic displacement is accomplished by the introduction of air which promotes the growth of aerobic organisms in much larger quantities than would occur naturally. These bacteria break down the organic solids in the wastewater. From the aeration mixing compartment,mixed liquid enters the cone shaped settling or clarifier compartment from the bottom. No mixing occurs in this quiet zone where solids separate from the liquid and settle to the bottom of the clarifier and re-enter the mixing compartment. The liquid that separates from the solids in the clarifier continue to flow upward to the discharge pipe. The Aqua Safe® models AS500, AS500EZ, AS600, AS600EZ, AS750, AS750EZ, AS1000, AS1000EZ,AS1500 and AS1500EZ(Figures 1 -3)are round tank configurations comprised of an aeration mixing compartment and a center clarifier compartment. The Aqua Safe® models AS500-3 Duo and AS600-3 Duo (Figure 4) are a fiberglass round tank configuration comprised of an aeration mixing compartment, a center settling or clarifier O&M Page 10 compartment and a 300 gallon attached pump tank with optional chlorination device and effluent filter. Wastewater first enters the aeration mixing zone. The mixed liquid next enters the clarifier compartment and continues to flow upwards to the discharge pipe. From the plant's discharge pipe, the final effluent passes through a chlorination device and the pump tank effluent filter into the pump tank compartment for storage and chlorine contact mixing. The treated and disinfected effluent is then safely discharged,via an application pump,to a surface spray,overland flow or other disposal area. The Aqua Safe® models AS500CU and AS600CU (Figure 5) are fiberglass round tank configurations comprised of an aeration mixing compartment and a center clarifier compartment. Additionally,they both have an attached 68 gallon chlorine contact tank with a chlorination device. The Aqua Safe® model AS500-P5CU (Figure 6) is a four compartment fiberglass tank configuration. It is comprised of a forward 500 gallon pre-treatment tank,an aeration mixing zone,a settling or clarifier compartment and a 68 gallon chlorine contact tank with a chlorination device. Wastewater first enters the pre-treatment tank compartment of the plant,then gravity flows through a 4" SDR 35 PVC inlet to the aeration mixing zone. The mixed liquid next enters the clarifier compartment and continues to flow upward to the discharge pipe. From the plant's discharge pipe, the final effluent passes through a chlorination device into the chlorine contact tank. The treated and disinfected effluent is then safely discharged in the disposal area. The Aqua Safe® model AS500 + 5 Duo (Figure 7) is a three compartment fiberglass tank configuration. It is comprised of a forward 500 gallon pre-treatment tank,an aeration mixing zone and a settling or clarifier compartment. Wastewater first enters the pre-treatment tank compartment of the plant, then gravity flows through a 4" SDR 35 PVC inlet to the aeration mixing zone. The mixed liquid next enters the clarifier compartment and continues to flow upward to the discharge pipe. The Aqua Safe® models AS500 + 5 Trio (Figure 8) and AS500 + 75 Trio (Figure 9) are four compartment fiberglass tank configurations with a chlorination device. They are comprised of a forward 500 gallon pre-treatment tank,an aeration mixing zone,a settling or clarifier compartment and a rear pump tank compartment. Model AS500+5 Trio has a pump tank flow line capacity of 500 gallons and model AS500+75 Trio has 750 gallons. Wastewater first enters the pre-treatment tank compartment of the plant, then gravity flows through a 4" SDR 35 PVC inlet to the aeration mixing zone. The mixed liquid next enters the clarifier compartment and continues to flow upward to the discharge pipe. From the plant's discharge pipe, the final effluent passes through a chlorination device into the pump tank compartment for storage and contact mixing. The treated and disinfected effluent is then safely discharged,via an application pump,to a surface spray,subsurface drip, low pressure dose, absorptive mound or other disposal area. The Aqua Safe® model AS500+5 Pre (Figure 10) is a three compartment concrete tank configuration. It is comprised of a forward 500 gallon pre-treatment tank,an aeration mixing zone and a settling or clarifier compartment. Wastewater first enters the pre-treatment tank compartment of the plant,then gravity flows through a 4" SDR 35 PVC inlet to the aeration mixing zone. The mixed liquid next enters the clarifier compartment and continues to flow upward to the discharge pipe. The Aqua Safe®model AS500-4+75(Figure 11)is a four compartment concrete tank configuration with a chlorination device. It is comprised of a forward 400 gallon pre-treatment tank,an aeration mixing zone,a settling or clarifier compartment and a rear 750 gallon flow line capacity pump tank compartment.Wastewater first enters the pre-treatment tank compartment of the plant,then gravity O&M Page 11 flows through a 4" SDR 35 PVC inlet to the aeration mixing zone. The mixed liquid next enters the clarifier compartment and continues to flow upward to the discharge pipe. From the plant's discharge pipe, the final effluent passes through a chlorination device into the pump tank compartment for storage and contact mixing. The treated and disinfected effluent is then safely discharged, via an application pump, to a surface spray, subsurface drip, low pressure dose, absorptive mound or other disposal area. The results of the Aqua Safe®process are a clear, odorless effluent discharge, which meets and exceeds state and national water quality standards. O&M Page 12 Aqua Safe Flow Diagram r"« 1S00tFlo Gatw Line Capaciyy 12"Dia.Insp.Port Dia.Rise ^w� 12 / \ / III __ 1 11 'I ��, 4''Wet '�* �1 i f T-Baf f 4"Int. , -Battle • N4"Outlet '1111111111111111111111111111111116. 4"90 BI -Baf11e/i } / 1 1 / • —•_ • "Outlet Optional / 1 } / >, i f i , k,t } ! 1 i : T 1 /"}'♦ 1 f i 4"PVC f .1/ 1 f / 1 1.� i:pa 1 li f }} .l i !MILM11110 }} i 1 f} 1 1 } f } f 1 } Pre Tank} if i f l 14 i ! 1 1 }1 1 ! i 516 Gal.f .i 1 } } f 1 f ! i } i 1 f I f ! 1 1 }I f ! r AS500+5 Pre AS500-5 Pre AS500,AS600,AS750,ASI000,AS1500 16"Riser w/Cap 12"Dia.Insp.Port "Di'Riser _ r, r,�,s, I_ hlorinator with 3" \ / i1 I \ ! I I_Drop Tube Lii T Bamr<' y 4"Inlet 1-Baffle I 1 1 Chlorinator with —;�/ 1 I 1 3"Drop Tube } 1 f 1 . fr f I }1 T uo cal. f} 1 INNIIIMI 1 Damp Tank 1 Pre Tank 1 1 I }} 1 + Pump Tank 1 IT 1 516 Gal. 1 1f 516Ga1. i i1 I f 1� - ,.1 l` a' 1 1 1 ` l, 1 1 AS500+5 Pump AS500 5+5 20"Riser w/Chlorioator Within Riser to ,"Dia.Riser �{ 12"Dia.Insp.Port . hlorinaWr with 3" 500 Gal Capac .._ iiiiiii. .11. . , a I I _ I' Drop Tube At Flow Line I J , ,6 II /11 �_� • 4"Inlet- II r I I T-B'` �•� T-BafllSI f 1 I / 1 } S chlorinator with 1 f I 4 I 1 } 1 3"Drop Tube : Pre Tank,'If r (Pump Tank i } f } 516 Gal.f �i f 580 Gal. 1 1 T /_f} N. i —ti�� /w1} 4 enac t f i i 4 T f 41 f rti50 Gat I f fl f . } P 'i i 1 f 1 } } } f1 T 1 f} 1 ! i f -+, 1 T ! . ! 1 I 1 \ ^ 1 � s.s. EIMMINO 1 `1 ! 1s , AS500 4+75 AS500 5+5 E el 16"Riser w/Cap ® :-6"Dia.Rises I i�� ,iiimmiiiir,tw JIB * =1 ", Ill mil p 4"Inlet P- • �4°Outlet 4"1n1 4"90E11 T-tattle /I • Optional / } 1 , / 1 T-BnDI / , { f 1 1 1 1 1 / 1 ar�IfI " ! 1 / 1 : I Filter Media Pipe f} (Optional) } f} 1 1 I I / 4 166 Gal.Pump Tank i f f 1 f 1 f (Attached) 1 I T ! 1 , 11 1 ! AS500,AS600,AS750,AS1000,AS1500 AS500-166 EZ Models -6"Dia.Riser /--16"Riser w/Cap 12"Dia.Insp.Port '"Dia.Riser �16"Riser w/Cap a 411111114111111.111 JIB II t�� 11 t _� 4"Inlet • - 111. ■ --I 4"Inlet �:� • / 1 LTIBaftle • ♦ •.wca.+n m l LT-Baffle / 4 •.C Bafll- I 1 } 1 ai 68�i rank ii ,,,, r 68 Cal �f� 4 / Iff >, 1 i _ 1 1 II 1 } 4 Pre Tankl .44 f f f 1 T ' 1 f 1 f } ! i 516Ga1.f 1 1 I . 66"for 500 GPD 70"for 600 GPD O&M Page 13 AS500-PSCU AS500-CU 04/2003 AQUA SAFE® PRODUCT SPECIFICATIONS INDIVIDUAL HOME WASTEWATER TREATMENT PLANT MODELS AS500, AS600, AS750, AS1000, & AS1500 Including EZ Models A.S. 500 A.S. 600 A.S. 750 A.S. 1000 A.S. 1500 Treatment Capacity 500 GPD 600 GPD 750 GPD 1000 GPD 1500 GPD Volumetric Capacity 1000 GAL. 1190 GAL. 1516 GAL. 2008 GAL. 2918 GAL. Aeration Zone Capacity 848 GAL. 1000 GAL. 1288 GAL. 1706 GAL. 2349 GAL. Clarifier Capacity 152 GAL. 190 GAL. 228 GAL. 302 GAL. 569 GAL. BOD5 Loading 1.25#/DAY 1.50#/DAY 1.85#/DAY 2.50#/DAY 3.75#/DAY Aerator-Aqua Safe Compressor ASC2532 ASC3342 ASC3352 ASC5082 ASC7510 DESIGN COMPONENTS AND MATERTIALS \eration Tank& Cover fiberglass or concrete Clarifier polyethylene or fiberglass Compressor Housing polyethylene, fiberglass, or concrete PARTS LIST Aeration Tank Fiberglass or Concrete item #1 Clarifier Fiberglass 2 Air Distribution System 3 Access Cover 20" Polyethylene or Concrete 4 Discharge Piping Assembly 5 Compressor Housing 6 DIMENSIONS MODEL A (I.D.) B (HEIGHT) AS500 5'6" 6'4" AS600 6'0" 6'4" AS750 6'9" 6'4" AS1000 6'9" 8'2" AS1500 8'2" 8'2" O&M Page 14 Aqua Safe AS 500 - 1500 With EZ Top *-20"Bot----).-i 25"Bo' y Q Jop i__ gil<5'' 1 20"Tu e Riser 1-<-1 2.5" / Aerator \ I Cover 12 g tJJJ. 11��6 C , _hit 1 FG Riser FG Riser i J 4"PVC Pipe " Inlet, ___.(-- 4 SDR x 4 DMV Coupling Baffle , B„ Clarifier -F A" Mixing Zone -E �R3 • - A 10"- \. v J Ecological Tanks, Inc. Patented 4/2002 O&M Page 15 FIBERGLASS e PANEL 0 .7 • . 0 ' A e a 0 119" 600GPD 113"500GPD VENT O AERATOR COVER 27" . � - �' _ I BASE I 16" E • FG RISER 4ii7...i. 9 i . _j� 4"PVC Pipe r 8._51" 4'PVC Pipe P. Outlet with 4" 4"INLET PRE TANK, \Soil Gasket `� / E OOl Coupling S IL GASKET 300 GALLON \ / \ TREATMENT TANK, / 500 GPD or 600 GPD 76" 70" I - \ 66" 500GPD \72" 600GPD/ FIBERGLASS \ / PANEL \ *— Fiberglass Clarifier 1 O&M Page 16 FIBERGLASS e PANEL a , T • . 0 _, __ 0 O\ / A m m 150" with UV Light I 20'RISER VENT r: E4'PVC C ilorinator ACCESS COVER with 3"Dip Tube _ nER•roR fwvn 271116 rr 1I .I Ie 1 I 1 Tf �F i11111111 FG RISER -_ -iiI r6r, i r i i t 1 1- 4"PVC Pipe __y 4'PVC Pipe& / „�T F ^O„ 4'INLET Soil Gasket IL,,., 3 SOIL GASKET ' \ / \ TREATMENT TANK, / r 500 GPD PRE TANK, 76" 500 GALLONI i ' 70" I-- \—66" 24" ` FIBERGLASS \ / PANEL \ `/ 28" ' /``/` Ciberglrss JClarifier 1 �_ / \ / O&M Page 17 AQUA SAFE TREATMENT PLANTS AIR LINE DIFFUSION 1/2" Ell 3/4"Spa Flex Pipe Air Inlet —N.N4,.' 1/2"x1/2"x3/4"Tee /00000011111=1111 Az_ 1/2. Tee a) 1/2"PVC Drop Line a a U > Q. 0 v I cn CV Spa Flex Pipe Size as required per chart A wv. • If Air Diffuser Distribution '_ 1/2"ELL i Hole Size & - I Quantity per ` i Chart Drop Line Design Chart DROP LINE(A) NO.HOLES PATTERN HOLE SIZE SPA UNIT O 3/8" SIZE&LENGTH SIDE BOTTOM DISTRIBUTION 3/4 , 3/8" 500 1/2"-64" 12 1 3/4x3/8 Stag 3/32" 1/2"Loop J4,' 3/8" 600 1/2"-64" 15 1 3/4X3/8 Stag 3/32" 1/2^Loop II II O3/8" Aso 1/z^64" 1z 1 3/4x3 B Stag 1/8" 1/2^Loop^3/8" 1000 1/2"-86" 15 1 3/4X3/8 Stag 1/8" 3/4"Loop • 3/8" 1500 1/2"-86" 18 1 3/4X3/8 Stag 1/8" 3/4"Loop 3/8" • S Mg NOTE: Holes Face Clarifier 2" 1/2"Cap 1 IleSIV \\_____1/811 Hole in Bottom ECOLOGICAL TANKS, INC. 01/2007 O&M Page 18 III. AQUA SAFE® RECOMMENDED PLANT INSTALLATION INSTRUCTIONS 1. Inspect entire treatment plant and component parts. 2. Select location of plant site which is accessible to the home sewer discharge line,at least ten(10) feet from the home foundation, in an area that will not receive vehicular traffic. Prepare an excavation site by digging a hole at least one (1) foot larger than the treatment plant and a depth that will allow for sufficient coverage leaving approximately three(3)inches of the inspection port to extend above normal ground level. The depth of the plant will be controlled by the depth of the building sewer outlet line plus the amount of proper fall required from the building sewer outlet to the inlet invert of the plant. The prepared excavation should have a solid, level bottom that will eliminate plant settling. Additionally,the bottom of the excavated hole should be free of rocks or sharp objects. Aqua Safe® plants should be installed on a bed of sand on undisturbed soil to provide a solid flat base. 3.Utilizing lifting lugs provided,carefully place the plant in the excavation. The inlet line should slope down toward the plant and the outlet line should slope down away from the plant. The plant should be level to within one (1) inch, edge to edge. Aqua Safe® wastewater treatment plants should only be connected to properly trapped and vented plumbing systems in compliance with state and local plumbing codes. 4. Position the inlet and outlet lines and make the necessary connections. Clean-outs should be installed at building sewer tie-in, any changes in direction of flow and at maximum intervals of seventy(70)feet when using four(4) inch piping. The inlet line should be inserted and glued into the inlet elbow and the discharge line should be inserted and glued into the outlet coupling. Open the inspection port on top of the plant and make sure the discharge tee assembly in level and centered in the clarifier prior to connecting discharge piping. Fill the tank with water to the point of flowing discharge before backfilling. Backfill evenly around the plant,up to the bottom of the inlet and outlet piping,taking care not to damage the tank or dislodge the piping. Backfill material must be void of rocks, gravel, heavy clay or any type of material which might damage the tank. 5. The aerator compressor must be installed in a well ventilated,relatively clean and dry location. Install the aerator compressor on the treatment plant's tank top or at a remote location no more than one hundred(100)feet from the treatment plant. The aerator compressor is supplied complete with all discharge fittings. Install 3/4"Sch.40 PVC piping(supplied by others)between the aerator and treatment plant. Be careful not to allow any debris,dirt or mud in the airline during installation.A minimum of twelve(12)inches ground cover is recommended over the 3/4"Sch.40 PVC air piping. 6. The electrical controls for the aerator compressor, visual and audible alarms for compressor failure and high water conditions, dose/spray pump and/or timer are contained in a weather proof enclosure. (See Figures 15-34). It may be installed in any above ground area where the warning light is visible to the owner during the course of a normal day activities. It is recommended that the control box be at least six (6) inches above ground level and in view of the aerator compressor housing. All electrical wiring must comply with applicable standards and shall conform to the requirements of the most current revision of the National Electrical Code.All electrical components not supplied must comply with U.L. standards. We recommend that all electrical connections be made by a licensed electrician. 7. Install electrical wiring(provided by others)to interconnect the aerator compressor and alarms to O&M Page 19 the electrical control panel. (See Figures 16-33). A minimum of twelve(12)inches of ground cover is recommended over underground electrical conduit and wiring. 8. If required, install the application pump in the pump tank. (See the Aqua Safe®effluent pump manual). Most aerobic system designs that include as a method of effluent disposal surface spray, subsurface drip, or low pressure dosing should include the proper sized pump for the job. If not, once the pumping conditions are determined,selection of the right pump will be determined by two factors, pump capacity and total head needed. You must match the pump as closely to your conditions as possible to get maximum pump efficiency and dependable operation. Install and set the float switches to the appropriate level to comply with design and state requirements.(See Figures 20&21). 9. Run approved conduit and wiring to the pump tank from the control panel and have a qualified electrician make wiring connections. (See figures 26-33 and Aqua Safe® pump manual). All conduit running from the pump tank to control panel must be sealed with conduit sealant to prevent moisture or gases from entering the panel. 10. The aerator compressors used on Aqua Safe®wastewater treatment plants run continuously. They provide relatively quiet, energy efficient operation. Once properly connected,the electrical control box is to be closed. Operate the aerator compressor by placing the on/off electrical circuit (provided by others) in the ON position. 11. Turn on aerator compressor and check all air piping and fittings for leaks. This can be accomplished by preparing a saturated solution of soap and water and applying to entire run of pipe and fittings. If a leak is detected,effect repairs. 12. Carefully backfill all underground lines and the rest of the plant's excavation in a manner which will not cause damage to the completed installation. 13. The Aqua Safe®plant is ready to receive incoming sewage. IV. AQUA SAFE PLANT START UP Initially the Aqua Safe® wastewater treatment plant is filled with clean water, usually from an owner's water supply. As stated in the installation instructions, once all proper connections have been completed and it is filled with water and the aerator compressor turned on,the system is now in operation.For the treatment plant to be biologically stable,it will take from four(4)to twelve(12) weeks after first using the plant to develop a population growth of microorganisms(bacteria). It is these bacteria which make the treatment system operate. V. OWNER MAINTENANCE CARE AND OPERATION INSTRUCTIONS Aqua Safe®home wastewater treatment plants have been designed and built by Ecological Tanks, Inc.to provide long term,reliable and cost efficient service. Our treatment plants will operate with a minimum amount of attention. If service is required, reference the system's DATA PLATES located on the Aqua Safe®control panel or aerator compressor for the plant's model number,the name,address and phone number of the local service person that can provide service. The following procedures should be performed on a routine basis to insure proper plant operation: O&M Page 20 DAILY:Check warning light and audible alarm located on the plant's control panel for air supply malfunction or in system high water indication. If an alarm on condition is observed, it is an indication of malfunction. First check the electrical circuit providing power to the system to insure the circuit is closed. Check the aerator compressor to be sure it is operating. Check for over heating,excessive vibrations and unusual noises. If aerator compressor failure is observed,call your service provider for service. After a power outage,an alarm condition may exist. Should an alarm remain on for more than thirty (30) minutes after power is restored, you should call your local service provider to report the alarm. WEEKLY: Check the treatment plant for offensive odor. If present call for service. PERIODICALLY:Check and clean the air filter on aerator compressor. Rinse with warm water to clean if necessary. Make sure filter is dry and re-install on aerator compressor. RECOMMENDED: Frequency of solids removal is no more often than every two (2)to five (5) years. Determination of the need for pumping can be made only by a trained service person by testing the tank contents and/or effluent. The Aqua Safe® wastewater treatment plant should be pumped when the settled solids are approximately sixty (60) percent of the total volume. WARNING -Hydraulic displacement and tank flotation may occur whenever tanks are pumped. Upon completion of pumping,tank must be refilled with water.Additionally,care should be taken not to damage internal componentparts. A certified Aqua Safe®service technician should oversee P q tank pumping. VI. OWNER'S RESPONSIBILITY It is the owner's responsibility to operate the Aqua Safe®wastewater treatment plant to the best of their ability. To keep maintenance to a minimum and insure high effluent quality, the following items should not be permitted to enter the treatment plant: 1. Strong disinfectants or bleaches,other than small amounts used in day to day house cleaning and laundries. Recommended detergents are low-sudsing, low phosphates and biodegradable. Recommended cleaning products are non-chlorine, non-toxin, non-corrosive and biodegradable. Anti-bacteria soaps should be avoided. 2. Backwash discharge from any type of water softeners. 3. Citrus products,coffee grounds,chemical wastes,paint or paint thinners,oils or grease(such as used cooking grease),pet shampoo,pet dip disinfectant,pesticides,herbicides,automotive fluids or any other toxins. 4. Disposable diapers, tampons, sanitary napkins, large quantities of paper products, tobacco products, or similar items. Home brewery waste, strong medicines and antibiotics. 5. Waste material from a garbage disposal is not recommended without the use of a trash trap or pretreatment tank preceding the Aqua Safe®plant. Food waste represents additional loading the aerobic treatment unit would have to digest, increasing pump out intervals. 6. The Aqua Safe® wastewater treatment plant is designed for the treatment of domestic wastewater and nothing else should go into it. During extended periods of intermittent or non-use, such as vacation time,the aerobic bacteria inside the plant will decrease due to no food in the form of incoming wastewater. The treatment plant will become biologically stable again soon after the resumption of normal loading. The aerator compressor should be left on during periods of vacation O&M Page 21 time. During extended periods of absolute non-use (3 months or longer) the aerator compressor should be removed,cleaned and stored with the compressor's inlet and outlet sealed. Additionally, the air line piping should also be capped to prevent debris from entering the air distribution system. The Aqua Safe®plant will not perform to its fullest capabilities if subject to hydraulic overloading. This condition exists whenever excessive water, above the plants designed treatment capacity, is allowed into the plant. Leaking plumbing fixtures or excessive water use may cause this condition. Hydraulic overload may also occur on wash days, when multiple loads of laundry are washed in succession. Ecological Tanks, Inc. is not responsible for the infield operation of our plants. The proper operation of this wastewater treatment plant depends upon proper organic and hydraulic loading of the plant. We cannot control the loading of substances in our plants that may upset its biological balance. We can only provide a complete owner's manual which outlines materials that should be kept out of the treatment plant. User operation instructions must be followed or warranties are subject to invalidation. WARNING! Ants and rodents are destructive to the mechanical and electrical equipment on wastewater treatment plants. Care should be taken to prevent infestation of ants near the plant. Damage or destruction of mechanical or electrical equipment by ants or rodents is not covered under manufacturer's warranty. Any and all safety requirements such as the electrical wiring, blower operation or plant discharge concerning the owner,their families,friends,or guests is the sole liability of the owner(see warranty and service policy). The electrical control panel contains a schematic for the system. However, the electrical control panel is sealed and contains no user serviceable parts. Test and alarm silence switches are located on the outside of control panel. WARNING! Service to the electrical control panel by a non-qualified person may result in a electrical shock hazard resulting in serious injury or death. If service is required contact your local authorized installer representative or maintenance provider. Many states already require the use of a chlorination unit behind all mechanical treatment plants for total effluent disinfection prior to fmal discharge. Ecological Tanks,Inc.recommends the use of a disinfection device behind its mechanical plants for total effluent disinfection prior to final discharge. VII. INSTALLER/MAINTENANCE PROVIDER OPERATION, REPAIR AND TROUBLESHOOTING Previous sections in this manual have covered the Ecological Tanks,Inc.,Aqua Safe® system's functions, specifications, design,proper installation procedure, start up, owner care and operation instructions. If at this point you are not totally familiar with the material already covered, you should read it again. Please payparticular attention to the precedingsection titled Owner's Responsibility. This section P covers information critical to the plants proper loading and function. You will find that this same information is listed in the Ecological Tanks,Inc.,Aqua Safe®Owner's Manual. Your assurance of the owner's receipt of their manual and the explanation of it's contents is most critical to the O&M Page 22 plant's proper operation. You will find, in the following sections of this manual, the Initial Service Policy. It covers information required of you as a maintenance provider in order for you to provide service in compliance with NSF/ANSI Standard 40. Additionally,most states have added to the requirements of this policy. You must know and adhere to all other regulatory agency requirements concerning mechanical plant service/maintenance standards.Ecological Tanks,Inc.,Aqua Safe®wastewater treatment plants should be inspected every six months for proper operation. Two years of maintenance is provided as a part of the systems certification requirements. Ongoing maintenance is usually part of a service agreement maintained between an owner and maintenance provider. Inspections should include any necessary adjustment of electrical controls and servicing of the component parts and should include a visual check of hoses, wires, leads, contacts, cleaning of i filters, removal of organic particles, and testing of alarms to ensure proper function. An effluent quality inspection consists of a visual check for color,turbidity,scum overflow,and an examination for odors. A mixed liquor inspection may be necessary if the plant is not performing properly or if offensive odors are present. If any improper operation is observed which cannot be corrected at that time,the user shall be notified in writing immediately. This notification shall advise the owner of the problem, if it is covered by the warranty, if not,the cost related to correcting the problem and estimated date for correction of said problem. VH-1. EXAMPLE OF A ROUTINE MAINTENANCE SERVICE CALL First check the system's control panel for any alarm or failure indication. Check the panel to insure proper incoming power by testing the incoming power supply. If you know power is incoming into the control panel, check the circuit feeding the control panel. Next, check the aerator simply to insure that it is running and then go directly to the treatment plant for an effluent quality inspection as outlined in the service policy section. At this point pay particular attention to odors you notice at the plant(or pump tank if applicable). You may notice an earthy smell which is nothing more than carbon dioxide gas emitted by the aerobic bacteria in the plant. There may be a sweet smell or no smell at all and that's good. Should you experience an obnoxious odor,something is wrong. Access the aeration mixing compartment,if necessary,to examine the mixed liquid and air diffusion system. Return to the control panel, check for proper functions as outlined in this manual (See figures 15- 24), note the troubleshooting and repair guidelines covered in the referenced figures. Before servicing the control panel and alarm system, disconnect power to the control panel. Clean or replace the aerator compressor air filter at this time. If you experienced an offensive odor when at the plant and heard little or no bubbling,finding a clogged or extremely dirty air filter may be the problem. Turn on the aerator at this time and check for any air leak between the aerator and the 3/4" Sch. 40 PVC piping. If a leak is detected, effect repair. If a leak is not detected, the following steps should be taken. Remove the aerator from the rubber hose connection and install a low pressure gauge between the PVC piping and aerator. Turn on the aerator and note the pressure. If the line pressure is below 1.5 P.S.I.then there is a leak between the aerator and the air distribution system in the treatment plant or the aerator's diaphragm is ruptured.(See the aerator compressor repair section)Determine the cause and effect repairs at this time. If a pressure above 3.5 P.S.I. is noted, the air system piping or diffuser assembly is blocked. You can clear the air distribution system's blockage by charging the air distribution piping with compressed air(no more than 80 P.S.I.) Re-check the line pressure after any maintenance procedure to the plant's air distribution piping to insure the correct pressure range. O&M Page 23 The normal line pressure should be between 1.83 PSI and 2.85 PSI. The Aqua Safe®aerobic treatment plant was designed and tested with a specific aerator compressor for each of its plant models (See Figure 35). Use only the specified aerator for each plant model provided by Ecological Tanks,Inc. in accordance with NSF Standard 40. If this particular system uses a gravity flow overland discharge,check to insure the discharge pipe or manifold is open. Should the system employ spray irrigation or some other method of pumped effluent disposal,you should check that method at this time. While at the chlorination or pump tank,if applicable,note the condition of the chlorination or other type of disinfection devise. Make sure that the disinfection devise is designed to insure effluent contact with the disinfection agent during periods of final effluent flow into the pump tank. Note the chlorine supply and check to insure that chlorine tablets are not caking inside the chlorinator resulting in no tablet to effluent contact. Effect necessary repairs if needed. Continue at the pump tank by checking the condition of the application pump and it's electrical connections. Note the positions of the pump on,off,override and high water float switches. Make sure they are properly positioned, operable and secured. Note the condition of the application pump's inlet screen. Clean or replace as necessary. Check to insure the pump is properly seated in the pump tank and note the condition of the pump's drop pipe as it extends from the pump discharge opening to the exit point out of the pump tank. Refer to Troubleshooting Guide found on the back page of the Aqua Safe® effluent pump manual if application pump problems warrant corrective action or repair. Some counties require the use of a spin or disc filter in line between the pump tank and spray application area. If subsurface drip application is used,you should always have a filter assembly in line between the pump tank and drip field. Counties that require the use of in-line spin or disc filters,as well as drip tubing manufactures alike,prescribe the use of the filter size and micron rating (normally 100 microns). Only approved filters should be used. If spin or disc filters are used they should be removed and cleaned or replaced and re-installed at this time. Continue by next checking the condition of the final effluent distribution piping system to include the surface spray or subsurface drip application area. Be sure that the distribution piping system and any repairs to the system conform to the applicable rules governing the construction of that system. Note any ponding or run off from the disposal area;determine the cause if either of these conditions exist. Probable cause would be either hydraulic overload of system or improperly sized disposal area. If water is ponding in the disposal area, it may flow back into the pump tank if the in-line check valve between the pump tank and disposal area is not completely closing after each pump cycle. Note any non-compliance conditions that may exist in the effluent disposal area and arrange for corrective measures. Activate the application pump and check the spray pattern and condition of the spray heads in the surface application area. Strainer screens if used in the spray heads may require cleaning. Any irregular spray pattern or damaged spray head must be noted on the reporting record and repaired. Also note the condition of the vegetation growth in the surface application area. Tall grass,weeds or bushes should be cut or trimmed.Notify the person responsible for performing that task and insure that it is done. If a subsurface drip application field is used,the system should be flushed at each regular service visit. Systems must be equipped to flush the contents of the lines back to the pretreatment tank when O&M Page 24 intermittent flushing is used. If continuous flushing is used during the pumping cycle,the contents of the lines must be returned to the pump tank. Check the atmospheric vents in the drip field to insure that they will open to vent and are readily accessible for inspection or service. Recommended procedures for taking effluent samples are outlined in Section VIII of this manual, titled Effluent Sampling Requirements. Be sure to follow the steps outlined in the Initial Service Policy,number 3,should you observe any improper condition affecting the plants proper operation which cannot be readily repaired. VII-2 AERATOR COMPRESSOR REPAIR Linear aerator compressors(See Figure 36-38)are used on all models of the Aqua Safe®wastewater treatment plants. They provide quite energy efficient operation. Additionally, rotary vane compressors(See Figures 39-42)are provided upon request, in-lieu of linear aerator compressors. All aerator compressors on all models of the Aqua Safe®aerobic wastewater treatment plants run continuously. Periodical aerator compressor maintenance will help you to operate the aerator in the optimum condition and insure longer aerator life. Air filters should be cleaned every four months and replaced as necessary. Ecological Tanks,Inc.recommends that the air filters be replaced once a year. The plant's air distribution piping pressure should be measured at least once per year. Aerator compressors should be operated at the recommended output pressure range which is between 1.5 and 3.5 P.S.I. Aerator life is shortened if operations outside of the specified pressure ranges occur. Ecological Tanks, Inc. recommends the diaphragm blocks on linear aerator compressors be replaced every three years. We also recommend that the vanes be replaced every four years on rotary vane aerator compressors. Referring to figures 36-42,note the following text for diaphragm block and vane replacement procedures: LINEAR COMPRESSOR HEAD AND DIAPHRAGM REPLACEMENT 1. Remove linear blower from electrical power and move to a well lit spot. 2. Remove the top plastic cover and discard the filter element. 3. Turn the blower over and remove(4)screws using either a#2 Phillips screwdriver or a 10 mm socket. 4. Remove the top housing and internal filter. 5. On Secoh,Thomas,and Gast HP series,remove the drive cover by taking out(4)Phillips screws. 6. Carefully,inspect the shuttle assembly and electric coils. Any damage to these components will require replacing the linear blower. 7. Using a pair of pliers, slide the hose clamp down the discharge hose and remove the hose from the head assembly. 8. Remove the head assembly by taking out(4)Phillips screws and separating the head from the O&M Page 25 diaphragm casing by prying the two pieces apart at the notch in the head. 9. Remove the diaphragm lock nut and washer. Slide the diaphragm block off the shuttle stud. NOTE: On the Gast units only,the diaphragm ring will also be removed during this operation. 10. Install the new diaphragm and casing by sliding the diaphragm over the shuttle stud and centering the diaphragm casing in the housing. Install the washer. Place(1)small drop of Loctite thread lock on the end of the stud and install the nut. Tighten to 14 in. lbs. 11. Install a new head assembly by locating the head over the diaphragm casing and tightening the (4)Phillips screws. 12. Slide the discharge hose back on the head and replace the clamp. 13. Follow procedure#7 thru 12 for the opposite side. 14. Install the internal filter and replace the blower cover. 15. Install the (4)Phillips screws,replace the filter element,and replace the filter cover. 16. Return unit to service. ROTARY COMPRESSOR VANE REPLACEMENT 1. Unplug compressor, disconnect piping and move to a suitable work area. 2. Remove(5) 7/16" hex bolts and remove front cover and gasket(if present). 3. Remove vanes while paying particular attention to the proper orientation of vanes in the rotor. 4. Using low pressure compressed air,blow out any dust or carbon particles from rotor and cylinder. (Always use safety glasses when performing this procedure). 5. Inspect the rotor,cylinder, and front cover for any signs of metal contact or cracks. 6. Rotate the rotor by hand to be sure the motor and bearings are free. 7. Install a new set of(4)vanes into the rotor slots. 8. With the motor resting on its base,rotate the rotor by hand to insure the vanes move freely. 9. Install the front cover and torque the (5)hex bolts to 10 ft.-lbs. 10. Replace the felt washers on the inlet filter. 11. Prior to installing compressor back on system, plug the unit in and let it run for a couple of minutes. Unit should have a constant hum and should not exhibit any excess vibration. 12. Unplug the unit and listen for the coast down of the compressor. The compressor should coast down to a dead stop. If the unit stops immediately,go back to step#2 and check for any metal to metal rubbing. 13. Install unit back on plant. O&M Page 26 VII-3. METHODS FOR EVALUATION OF EFFLUENT AND MIXED LIQUOR Problem Possible Cause Corrective Action Offensive odor from Aerator or air piping Check aerator, air plant and effluent. defective, leaking or piping and alarm system. or clogged Murky to gray mixed Plant starving due to Confer with homeowner liquor with semi-clear infrequent loading, hydraulic regarding loading. effluent having a sour overloading, or oversized Remember it may take 4 to odor. pretreatment tanks resulting 12 weeks for a new plant in totally anaerobic,or low to start. BOD influent. Black colored mixed Plant receiving little or no Check aerator,air piping liquor&effluent having aeration due to defect in &alarm system. a totally septic odor aerator or air piping. void of dissolved oxygen, having a approximate pH between 6.5 & 8. Black colored mixed Plant loaded or dosed with Confer with homeowner liquor&black tinted influent that prohibits growth regarding loading. Adjust effluent having an of aerobic bacteria pH to between 6.5 & 8.5 offensive odor&acidic dose system with approved pH bacterial additives to help restart micro- bacterial growth or pump tank for fresh start. Brown mixed liquor Developed population of Confer with homeowner with a viscous, brown filamentous microorganisms regarding proper plant foam having an in aeration zone due to low loading. Adjust pH to obnoxious odor in the food to microorganism ratios, 6.5 & 8.5. Dose plants mixing zone with semi- the presence of toxins or im- mixing zone with approved clear effluent high in proper pH level. bacterial additive. TSS Problem Possible Cause Corrective Action Plant workingproperly with None required Chocolate brown mixed p pe y q liquor with clear effluent effluent pH between 6.5 & quality having only a 8.5 and D.O. level between slight earthy smell in 1 and 5.5 mg/L. mixing zone. O&M Page 27 VIII. EFFLUENT SAMPLING REQUIREMENTS When properly loaded,operated and maintained the Aqua Safe®wastewater treatment plant should provide an effluent quality consistent with the E.P.A. secondary treatment guideline parameters. The expected final discharge from the plant should provide an effluent quality of: less than 25 mg/l. CBOD5 less than 30 mg/1. TSS pH of 6to9 Test results conducted by Baylor University's Department of Environmental Studies in accordance with NSF/ANSI Standard 40 requirements showed the Aqua Safe®wastewater treatment plant to have a 30 day effluent average of: 2.37 mg/1. CBOD5 2.11 mg/I. TSS Ecological Tanks, Inc. recommends that ALL final effluent samples be taken in the effluent discharge line or the effluent pump discharge line at a sampling port designed for that purpose,but always after the chlorine contact tank. We recommend allowing the effluent to flow through the discharge pipe for a minimum of two (2)minutes before taking the sample. VIII-1. SAMPLING AND TESTING PROCEDURE FOR BODS OR TSS 1. Effluent grab samples to be analyzed for BODS or TSS should be done by a certified testing lab. The certified lab should provide you with information concerning proper sample collection to include volume,storage and labeling of sample. For a fee,most labs will provide the glass or plastic bottles to be used. 2. Always follow your testing lab's instructions concerning proper sample labeling,collection,and storage. For the referenced sample collection in this section,the testing lab's minimum instructions should be: A)Label each sample to include: *Name and physical address of owner * Time and date of collection * Desired test *Name of person collecting sample B)Collect samples only in clean glass or polyethylene bottle or jar at a volume specified by the lab. C) Store samples in a cooler to near freezing temperature as soon as samples are collected. D)Deliver samples for analysis within six(6)hours of collection. 3. Activate the application pump and collect the sample from the sample port in the pump tank or from fresh flow in the effluent discharge line after the disinfection devise. O&M Page 28 VIH-2. TESTING FOR SOLIDS REMOVAL 1. As previously noted in other sections of this manual a sample of mix liquor should be taken from the aerobic plant's aeration mixing compartment to determine the suspended solids content of the aeration compartment. 2. Using a clear glass or plastic graduated cylinder,let the sample settle for thirty(30)minutes. If the settled amount of suspended solids is greater than sixty percent(60%)after thirty(30)minutes, the aerobic tank should be pumped out. VIII-3. OTHER TESTING 1. To determine the composition of the aerobic plant's influent wastewater strength,collect a grab sample from the flow between the pre-treatment tank and aerobic treatment plant. 2. Samples should be taken from fresh flow directly out of the pre-tank's outlet baffle. Refer to information covered earlier in this section for proper handling of a sample from the job site to a certified testing lab. 3. Influent grab samples,at a minimum,should be analyzed for BOD5,TSS,COD,and pH. A pH test can be done on the job site by following the simple instructions with your pH test kit. However, BOD5, TSS, and COD tests should be conducted by a certified lab. 4. The need to determine the concentration of other influent contaminates may arise. Collect, handle and test the samples in the same manner as outlined in this section. 5. The typical composition of untreated residential wastewater for the suggested parameters is: BOD5 180 to 200 mg/1 TSS 180 to 200 mg/1 COD 75 to 150 mg/1 pH 6 to 9 IX. ORDERING OF SYSTEMS, PARTS, AND MANUALS Ecological Tanks,Inc.,Aqua Safe®maintains ample supplies of parts to meet the needs of new sales, replacement parts, warranty parts, and manuals. Please feel free to call us or your local distributor so we can help meet these needs. O&M Page 29 SOURCES FOR OBTAINING REPLACEMENT PARTS OR COMPONENTS Replacement parts or components may be obtained from your local installer/distributor or from: Ecological Tanks, Inc. 2247 Hwy 151 N. Downsville, LA 71234 Office: 318-644-0397 Fax: 318-644-7257 PARTS LIST Refer to system, aerobic control and aerator compressor schematics. DATA PLATE / SERVICE LABELS INFORMATION AQUA SAFE Ecological Tanks,Inc. NSF 2247 Hwy 151 N. Downsville,LA 71234 318-644-0397 COMPONENT Model#ASXXXX-XXX Class 1 Size XXXX GPD For service call your local service provider The above weatherproof vinyl label is permanently affixed to the front of the electrical control panel. AQUA SAFE Ecological Tanks,Inc. 2247 Hwy 151 N. Downsville,LA 71234 NSF318-644-0397 Serial#ASXXXXXXX Model #ASXXXX-XXX Class 1 Size XXXX GPD For service call your local service provider The above weatherproof vinyl label is permanently affixed to the aerator compressor O&M Page 30 HIBLOW HP80-01 3A Compressor Alarm Module Operating Instructions A Danger: Do not attempt to open the alarm module. If the unit is connected to electricity, opening of the alarm module can result in a risk of electric shock. A Danger: Service of the alarm module should only be done by a qualified electrician or serviceman. A Danger: If the outside of the alarm module or light lens becomes cracked or damaged, unplug or shut-off the electric power immediately and contact an electrician or serviceman. 0 Caution: Do not carry the unit by the alarm module or electrical cord. It could damage the alarm module. Light Lens Alarm Module INS „Immili , = ,\ - L IttkUM=MMITFAM viLAvang - ,• Toggle Switch - apgThe three position toggle switch is clearly labeled on the alarm module. /RUN\ `� �j R UN : During normal operation the switch is in the PANE TEST MITE TEST "RUN" or center position. MUTE : The "MUTE" position will silence the audible alarm while leaving the visual alarm operational. TEST : The "TEST" position will activate both the audible and visual alarms to check to see if they are working. In Case of an Alarm : The alarm module audible alarm (buzzer) and visual alarm (light) are intended to signal a system malfunction. Contact your service provider whenever you hear or see the alarm when the switch is in the "RUN" or center position. The "MUTE" position can be used to silence the audible alarm until the service provider arrives. Ecological Tanks,Inc. Patent Pending 03/2004 0&M Page 31 Aerobic Control AQUASAFE® Installation Instructions and Operation/Troubleshooting Manual Control panels must be installed and serviced by a licensed electrician in accordance with the National Electric AWARNING! Code NFPA-70, state and local electrical codes. All conduit running from the tank to the control panel must be all SHOCK HAZARD , sealed with conduit sealant to prevent moisture or gases from servidng_Failure to do so could result entering the panel. lirin serious injury or death. Installation The aerobic treatment system panel is designed to operate an air compressor and effluent pump, in addition to providing air com- pressor fail and high water level alarm functions. NOTE: Options ordered may affect the number of floats and their functions. Please reference the schematic provided with the control panel for proper installation. Installation of Floats CAUTION: If float switch cables are not wired and mounted in the correct order, the pump system will not function properly. WARNING: Turn off all power before installing floats in pump chamber. Failure to do so could result in serious or fatal electrical shock. 1. Label floats for specific operation (high water alarm, pump on/ off and timer override). See schematic for float options. 2. Determine your normal operating level as illustrated in Figure 1. 3. Mount float switches at appropriate levels via stationary device as illustrated in Figure 2 & 3. Be sure that floats have free range of motion without touching each other or other equip- ® ment in the basin. AQuA SAFE Mounting the Control Panel 1. Determine mounting location for panel. if distance exceeds the length of either the float switch cables or the pump power cables, splicing will be required. For outdoor or wet installation, we recommend the use of a liquid-tight junction box with liquid- tight connectors to make required connections. O&M Page 32 FIGURE 20 Installation Instructions 2. Mount control panel. 8. Determine location for mounting junction box according to state and local code requirements. Mount junction box to 3. Route 1/8"airline tubing from"T'at compressor manifold to proper support. Do not mount the junction box inside the control panel. tank. 4. Slide 1/8"airline tubing over bulkhead connector on bottom g, Run conduit to junction box. Drill proper size holes for the of control panel. type of conduit used. Attach connectors to junction box. 5. Determine conduit entrance locations on control panel. 10. Identifyand label each wire before pullingthrough conduit g Be sure the power supply voltage and phase are the into control panel and junction box. Make wire splice con- NOTE: same as the motors being installed. If in doubt,see the nections at junction box. identification plates for voltage/phase requirements. 11. Firmly tighten all fittings on junction box. 6. Knock out proper size holes for type of connectors being 12. If a junction box is not required, identify and label pump cable used. before pulling through conduit into control panel. NOTE: If usimg conduit, be sure that it is of adequate size to pull the pump and switch cables through. 13. Connect pump and switch wires to terminals as seen on wiring diagram. 7. Attach cable connectors and/or conduit connectors to control panel. 14. Connect"power-in"conductors to proper locations: 120 volt FOR INSTALLATION REQUIRING A SPLICE, AC power(Hot(Li)and Neutral (N))to terminals as seen on FOLLOW STEPS 8-11; wiring diagram provided with control panel. FOR INSTALLATION WITHOUT A SPLICE, GO TO STEP 12. VERIFY CORRECT OPERATION OF CONTROL PANEL AFTER INSTALLATION IS COMPLETE. NOTE: The compressor fail alarm will sound until the system has reached normal operating pressure. secure cable under / strop , HIGH WATERC, 'I' ALARLAR M 3.5 inch(9 cm) minimumON f$y tether length /--'',..i. 11 secure cabie p I Name) t i W5 and pipe V operating •^�e . l 1, '1 Sea FIGURE oincn Ito cm) 01 A for mounting - '�7 ' minimum . l e tamp detail ( I%�t /41 46, tether length , Ali; \ a I ' , I� (2.5 cm) apart headstrap two releasable tab FIGURE 1 -SJE wide angle*float system FIGURE 2-Pipe clamp mounting detail FIGURE 3-Pipe clamp mounting detail `Junior Super Single® for high water alarm float for pump on/off float. (See chart below to determine pumping range) Determining Pumping Range in Inches (1 inch = 2.5 cm) Use only as a guide.Pumping ranges are based on testing in non-turbulent conditions.Range may vary due to water temperature and cord shape_ Note:As the tether length increases,so does the variance of the pumping range. Pr s' lam S..,P. '''_ .. 3 :i 10 4 15 -. .. . Junior Super Single® tether length f n 6 ) ��� , , k pumping range pumping 4, �` 8 5 �� 13 I. p 17 w range IE Vito.�- ° a Fi C)RM Patna T1 Installation Instructions Setting the timer (optional) O O The timer is a 24 hour time clock with 15 minute increment settings. The captive trippers change the 1 1Z ill /� / SPDT relay state when pushed toward the outside. �� 1. Setting time of day `It ' 12 (a) Synchronize the timer by aligning arrow at the 2:00 e� ,,► position of inner face with the corresponding time of day printed on the outer ring. NOTE: Power must be ON to ` "- ( ‘:= 1 0'lr V keep time synchronization. -It)- 9 cl All -V1- 2. Setting ON time and duration Ilm . i�1 Locate desired activation time(s) on outer ring (b) and � '.4- push trippers to the outside(c).Each tripper represents , 15 minutes activation time. Push as many trippers back ,� 4,, as desired for duration time.When the timer reaches the isi6 A, first tripper, the timer SPDT contacts will change state and tum ON.It will remain ON for as longas the following 9 6 I ` trippers arepushed out. When timergoes past last � �, � PP ll Z tripper,the timer will return to the OFF mode.The timer has a selector ford OFF O AUTOMATIC(blank),and O 0 MANUAL OVERRIDE (I) modes. FIGURE 3 -Timer detail Operations The Aqua Safe aerobic control was designed to The alarm circuit, compressor circuit,and effluent pump operate a single-phase air compressor and effluent pump. circuit each contain a thermal-magnetic circuit breaker for The control incorporates an audio/visual alarm for high branch circuit protection and disconnect. water conditions and air compressor fail. A test/normal/ Certain models of the aerobic control utilize a 24-hour silence switch, which is located on the side of the enclo- timer to control the effluent pump.The effluent pump is sure, allows the user to test the alarm horn and light, or controlled by a pump switch for dosing sizes and a timer for silence the horn while keeping visual indication. The alarm selecting periods of the day to allow dosing or spraying.A indication will remain active until the condition is cleared. timer override float may be included as an option to allow The high water alarm is activated via a normally open float dosing/spraying in high demand situations. switch. The air compressor fail alarm is activated either by a circuit breaker trip or a low air pressure condition. NOTE: If the horn is silenced in an alarm condi- tion, the switch must be returned to the `normal" or center position once the problem has been cleared. 0&M Page 34 Model 103 Field Wiring Diagram CONTROL PANEL r r Bare Copper . .,•CI Black W I— O_ w Q Q g a. a CI White Isolated Z S 5 0 D m Chassis Neutral = I U o- a Ground Incoming Power — from ❑N © ;U El ElCI 0. TB1 Service Entrance Panel -ps--- ----- ---- ---- ---- r -1 % '. '•. ;' Branch Circuit rating: . . '•. .• 120/60/1,20 Amps •'•• ��'''... ..•• ' • ratingof5kArms '•. symmetrical (BLACK) '''•... .: ALARM HITS FLOAT SWITCH CONTACT RATED 120/60/1 VAC, AM 1 AMP MIN (BLACK) AERATOR ULAPPROVED RATED 120/60/1 VAC PUMP (WHITE) FLA-5 AMPS MAX. FLOAT THERMALLY RATED 120/60/1 VAC PROTECTED 1/2 HP MIN PUMP ULAPPROVED RATED 120/60/1 VAC, 1/2 HP MAX, THERMALLY PROTECTED Notes for field installed components: 1. Main Disconnect, Branch Circuit Protection, wiring and external components to be provided by installer. 2. Field wiring -#12—#10 AWG, 60°C min, use copper conductors only. 3. Field installed conduit fittings must be rated for use with Type 3R Enclosure. 4. Torque Terminal Block, Neutral and Ground screws to 15—20 in-lbs. 5. Conduit openings must be sealed around wiring with an electrical grade(non-corrosive)sealant to prevent potentially harmful vapors from entering the control panel. O&M Page 35 Model 103 Schematic Diagram "PUMP" f 20A CB "COMP" •—•'-' 15A CB "ALRM" •—•%- 15A CB TEST/MUTE • SWITCH ALARM • _1 LAMP O PUMP TEST ALARM SWITCH HORN Chassis Ground r N L 1 I Y © CI5 : TB1 n Isolated W < Q a CL I- Neutral Z 5 2 2 co 11 I I 0 0 a a D a. O&M Page 36 Model 105 (Metal Demand) Field Wiring Diagram CONTROL PANEL r � QBare Copper CI Black • .' d d w d Q White W Q Q 2 2 S' 2 Isolated Z 5 5 0 o Chassis Incoming Power • Neutral I U a. z a- Ground • from [ 1i AI © © fl TB1 Service Entrance - • Panel .'�` : Branch Circuit rating: �•, ••.• • 120/60/1,20 Amps '• • •• W/Short Circuit �••� '••� ••••• Current �••� •.� •••••• rating of 5kA nns • � •, •.....: ■...• •....•••••••. ••�•�.° symmetrical (BLACK) -0........... ALARM ITE FLOAT SWITCH CONTACT, RATED 120/60/1 VAC, 1 AMP MIN • AERATOR (BLACK) UL APPROVED PUMP RATED 120/60/1 VAC FLOAT (WHITE FLA-5 AMPS MAX. RATED 120/60/1 VAC THERMALLY 1/2 HP MIN PROTECTED PUMP ULAPPROVED RATED 120/60/1VAC, 1/2 HP MAX, THERMALLY PROTECTED Notes for field installed components: 1. Main Disconnect, Branch Circuit Protection, wiring and external components to be provided by installer. 2. Field wiring -#12—#10 AWG, 60°C min, use copper conductors only. 3. Field installed conduit fittings must be rated for use with Type 3R Enclosure. 4. Torque Terminal Block, Neutral and Ground screws to 15—20 in-lbs. 5. Conduit openings must be sealed around wiring with an electrical grade(non-corrosive)sealant to prevent potentially harmful vapors from entering the control panel. O&M Page 37 Model 105 (Metal Demand) Schematic Diagram "PUMP" —' 20A CB "COMP" 1)-0 - 15A CB "ALRM" .—.��• 15A CB TEST/MUTE • SWITCH ALARM LAMP O • AIR • • SWITCH PUMP TEST ALARM SWITCH HORN O w Chassis Ground C EL' 2 © 0 5 6 ' TB1 n Isolated w < QCl_ CL Neutral Z 5 W _ = 0 D U d 2 a. O&M Page 38 Model 106 (Metal Timed) Field Wring Diagram CONTROL PANEL r r Bare Copper Lu +.•a Black 0 W • W Q Q 2 2 cc w g 41 White Isolated Z 5 O > > > Chassis Neutral —I 2 = U 0- O 0- Incoming Power Ground from 4N �L �1 I II CI El ©, TB1 'A. :•% Service Entrance -- -------- - — • :• Panel •� •� �. Branch Circuit • •• •• rating: ALARM FLOAT '•.. • • •.••• 12o/60/1,20 Amps SWITCH CONTACT, "•.. ' ►•. ••' •••' W/Short Circuit RATED 120/60/1 VAC, •' �..... ■. ..... ..... ........... ...... Current '• rating of 5kA rms 1 AMP MIN .... .....�........... (BLACK) symmetrical (WHITE) (BLACK) OVERRIDE FLOAT (WHITE) RATED 120/60/1 VAC 1/2 HP MIN (BLACK) AERATOR ULAPPROVED (WHITE) RATED 120/60/1 VAC PUMP FLOAT • FLA-5 AMPS MAX. RATED 120/60/1 VAC THERMALLY PROTECTED 1/2 HP MIN rI PUMP ULAPPROVED RATED 120/60/1VAC, 1/2 HP MAX, THERMALLY PROTECTED Notes for field installed components: 1. Main Disconnect, Branch Circuit Protection, wiring and external components to be provided by installer. 2. Field wiring -#12—#10 AWG, 60°C min, use copper conductors only. 3. Field installed conduit fittings must be rated for use with Type 3R Enclosure. 4. Torque Terminal Block, Neutral and Ground screws to 15—20 in-lbs. 5. Conduit openings must be sealed around wiring with an electrical grade(non-corrosive)sealant to prevent potentially harmful vapors from entering the control panel. O&M Page 39 Model 106 (Metal Timed) Schematic Diagram "PUMP" —' 20A CB "COMP" •—✓• 15A CB "ALRM" •—•�.--• 15A CB • ALARM • ; LAMP • A • A 1 • — O • OOD AIR 24Hr. SWITCH • • TIMER TEST/MUTE SWITCH ALARM HORN 1 PUMP TEST SWITCH Chassis Ground El C C 14 5 6 F TB1 Isolated uJ < Q a d W - Neutral _Z 2 a w J I I 0 U - Lu > 2 0 a O&M Page 40 Model 202 (Poly Demand) Field Wiring Diagram CONTROL PANEL r r aBare Copper ~ / I Black cn w .. 2 2 a a W a- : .. C white w tY tY 2 g S' g : Isolated Z O D b D Chassis • : Incoming Power —i Neutral < < 0 d Z 0_ Ground . • • • from ❑N : 1� ❑2 L3 0 05 © 7❑; TB1 Q Service Entrance -- - Panel • • • �• .•,• ; •• Branch Circuit rating: '� ••• ......• • . 120/60/1,20 Amps Current ..... ••• • rating of 5kA rms .�.■■.■••••'•� .• symmetrical (BLACK) •••••� `••....•..„ ..... • ,,,,„.....• ,,,„ . ' (WHITE) ALARM FLOAT SWITCH CONTACT, RATED 120/60/1 VAC, • 1 AMP MIN IAERA(BLACK) ( TOR ULAPPROVED RATED 120/60/1 VAC (WHITE) FLA-5 AMPS MAX. PUMP FLOAT THERMALLY PROTECTED RATED 120/60/1 VAC 1/2 HP MIN PUMP ULAPPROVED RATED 120/60/1VAC, 1/2 HP MAX, THERMALLY PROTECTED Notes for field installed components: 1. Main Disconnect, Branch Circuit Protection,wiring and external components to be provided by installer. 2. Field wiring -#12—#10 AWG, 60°C min, use copper conductors only. 3. Field installed conduit fittings must be rated for use with Type 4X Enclosure. If used, metal conduit fittings must provide means to bond conduit to ground terminal. 4. Torque Terminal Block, Neutral and Ground screws to 15—20 in-lbs. 5. Conduit openings must be sealed around wiring with an electrical grade(non-corrosive)sealant to prevent potentially harmful vapors from entering the control panel. O&M Page 41 Model 202 (Poly Demand) Schematic Diagram "PUMP" 20A CB "COMP" 10A CB "ALRM" •-��+ 10A CB • ALARM • LAMP •n T M O AIR • • SWITCH PUMP TEST TEST/MUTE SWITCH SWITCH ALARM HORN w Chassis Ground c 4 ©© � , TB1 n Isolated al CL CL F Neutral J CC O 1-1-1U Q Q a a_ 0_ O&M Page 42 Model 203 (Poly Timed) Field Wiring Diagram CONTROL PANEL r QBare Copper .• 1 • u j I i.G Black W • • g g a a ° °- Q White Isolated Z .. _I 0 > > D Chassis ' Neutral — < < 0 Q- 0 EL Ground Incoming Power from Service Entrance Panel r i •• ■ El : 1 ❑2 1 0 ❑5 III 7❑: TB1 Q • Branch Circuit rating: • . 120/60/1,20 Amps •: W/Short Circuit Current • •.•• •• rating of 5kA rms ALARM FLOAT ••.•.. ....... ••.y ••.•• • symmetrical •� SWITCH CONTACT, • RATED 120/60/1 VAC, �•••• •• •••• •••• ••• •.•••• 1 AMP MIN ( )BLACK) ••...... I'•..■. . ...a (BLACK) OVERRIDE FLOAT (WHITE) RATED 120/60/1 VAC 44 1/2 HP MIN (BLACK) AERATOR ULAPPROVED PUMP FLOAT (WHITE) . RATED 120/60/1 VAC RATED 120/60/1 VAC FLA-5 AMPS MAX. 1/2 HP MIN I THERMALLY PROTECTED I PUMP ULAPPROVED RATED 120/60/1 VAC, 1/2 HP MAX, ;, THERMALLY PROTECTED Notes for field installed components: 1. Main Disconnect, Branch Circuit Protection,wiring and external components to be provided by installer. 2. Field wiring -#12—#10 AWG, 60°C min, use copper conductors only. 3. Field installed conduit fittings must be rated for use with Type 4X Enclosure. If used, metal conduit fittings must provide means to bond conduit to ground terminal. 4. Torque Terminal Block, Neutral and Ground screws to 15—20 in-lbs. 5. Conduit openings must be sealed around wiring with an electrical grade(non-corrosive)sealant to prevent potentially harmful vapors from entering the control panel. O&M Page 43 Model 203 (Poly Timed) Schematic Diagram "PUMP" —• • 20A CB "COMP" •—•% 10A CB "ALRM" �.�.--• 10A CB • ALARM • i i� LAMP O • � AIR 24 H r. • • SWITCH TIMER TEST/MUTE SWITCH ALARM • HORN PUS WMPITCH TEST • Chassis Ground N ' 1 2 E. I5 6 7 ; TB1 rG Isolated uJ d 0_ p I— Neutral Z C O 2 > Q Q 0 a 0 a. O&M Page 44 MODEL 206 Field Wiring Diagram CONTROL PANEL TB2 (For In Coming Telephone Line CC 2 g Hookup) X < g g ;T 1❑ El R; CIBare Copper w Q Q w TB1 a cc i— I- n 0 ;.-0 Black a Q • w OJ O I— z O 1_ E 2 = a. a w a. O O C white Isolated z j 0 D D _ = Chassis • Neutral -' < 2 0 a H a- 0 0 Ground Incoming Power •t • from [N :El E2 f 0 Q El Iii ® g❑ CI Service Entrance : •• • • Panel . —...*„ens ` ; Branch Circuit rating: •. •••en•; •i• 120/60/1,20 Amps W/Short Circuit • .. • .•'��• •: Current •.• •. rating of 5kA rms ----r- -.- •......... \ ••••• ••• symmetrical ALARM • "i. FLOAT • •..... OVERRIDE AERATOR FLOAT UL APPROVED RATED 120/60/1 VAC FLA-5 AMPS MAX. THERMALLY PROTECTED PUMP FLOAT ' GREEN 2 BLACK 3 PUMP WHITE 1 ULAPPROVED RATED 120/60/1VAC, PUMP 1/2 HP MAX, THERMALLY PROTECTED CHLORINE LEVEL SENDING UNIT Notes for field installed components: 1. Main Disconnect, Branch Circuit Protection,wiring and external components to be provided by installer. 2. Field wiring -#12—#10 AWG, 60°C min, use copper conductors only. 3. Field installed conduit fittings must be rated for use with Type 4X Enclosure. If used, metal conduit fittings must provide means to bond conduit to ground terminal. 4. Torque Terminal Block, Neutral and Ground screws to 15—20 in-lbs. 5. Conduit openings must be sealed around wiring with an electrical grade(non-corrosive)sealant to prevent potentially harmful vapors from entering the control panel. O&M Page 45 917 abed W'80 0 LINE Q on ALARM 0 • POWER • r n I LA - I. HIGH WATER O • H ALARM • • p\i O COMP •• •Amal • t •PUMP ❑n II TIMER Q jjjjj` OVRD • PUMP ❑� TEST I I - C HLOR. LOVy ALARM ,- • C,- C HLOR. OUT El ALARM TIP 0 �, R I N GLiv Model 227 / RDPA Field Wiring Diagram ALARM UNIT CONTROL UNIT (INDOOR UNIT) (OUTDOOR UNIT) (Section 1 of 2) (Section 2 of 2) m a O a) 2 V Y ` N al la ° m CO a)CO -1 I Ce o o z z g z g Z Lu z --J 0 z Z < 1.1 Z - < U TB1 ;� El Q3 4 Twist Nut - y_ Connections ti Incoming Power 0 in from n Branch Circuit Service Entrance C0 U rating: Panel 120/60/1,20 Amps m m Notes for field installed components: 1. Main Disconnect, Branch Circuit Protection,wiring and external components to be provided by installer. 2. Field wiring-#12—#10 AWG, 60°C min, use copper conductors only. 3. External components(compressor and/or pumps) supplied by others and must be U. L. approved thermally protected motors. 4. Torque Terminal Block, Neutral and Ground screws to 15—20 in-lbs. 5. Conduit openings must be sealed around wiring with an electrical grade(non-corrosive)sealant to prevent potentially harmful vapors from entering the control panel. O&M Page 47 Model 227 / RDPA Schematic Diagram (Section 2 of 2) (Section 1 of 2) ALARM UNIT CONTROL UNIT (INDOOR UNIT) (OUTDOOR UNIT) ALARM • •r; i itMP 10A PUSH TO / • • RESET CB -ter DISCONNECT (� NO NC SWITCH DUAL AIR SWITCH TEST/MUTE El RECEPTICAL SWITCH ALARM HORN c N t N N v M© 0M0M Twist Nut TB1 ;0 la © 0 4 M V Ground V V V Connections Y ii i Y 'p N -,(L.)' _� Y 'p m 3 m m m 5 m z J E- ct Z Z Q Z Z I- O < =O =O I- Z J W Z Q 0 0 w < Z —J Z O&M Page 48 Model RAB BASIC Field Wiring Diagram REMOTE ALARM UNIT r ill: LINE IN (Black) 7'1 ALARM (Red) NEUTRAL (White) TB1 (Section 2 of 2) CONTROL PANEL r (Section 1 of 2) i a 2 a- Z (6 Q i r/� m JQ CC Q \ I Bare Copper Z CC w U Z W RECEPTACLE Q a� *.•o� Black z U m TB1 ; 2❑ E [�� White • Incoming Power •• -::::••••.' from • .••. •• Service Entrance Panel 4 AERATOR UL APPROVED RATED 120/60/1 VAC FLA-5 AMPS MAX. THERMALLY PROTECTED Notes for field installed components: 1. Main Disconnect, Branch Circuit Protection, wiring and external components to be provided by installer. 2. Field wiring -#12—#10 AWG, 60°C min, use copper conductors only. 3. Field installed conduit fittings must be rated for use with Type 4X Enclosure. 4. Torque Terminal Block, Neutral and Ground screws to 15—20 in-lbs. 5. Conduit openings must be sealed around wiring with an electrical grade (non-corrosive)sealant to prevent potentially harmful vapors from entering the control panel. O&M Page 49 Model RAB BASIC Schematic Diagram (To Remote Alarm Unit) LINE IN(Black) ALARM(Red) NEUTRAL(White) (Section 1 of 2) (Section 2 of 2) CONTROL PANEL REMOTE ALARM UNIT r —.1 ALARM 10A PUSH TO LAMP RESET CB • • I • � , ♦ DISCONNEC I NO•"•' NC SWITCH --- -- O t DUAL AIR SWITCH TEST/MUTE SWITCH ALARM RECEPTICAL HORN • 0 E �3 []2 Q; TB1 T61 ;0 2❑ 30: N W 0 ast asm w s co co m Z —1Z Z Et --I 0 I— z Z LLJ _1I— 0 W J Q D Z W Z O&M Page 50 L_ MODEL DRP-1, 120VAC DRIP CONTROL PANEL, SINGLE FIELD, Field Wiring Diagram Software version DRP-0001-0000 r r w ; CI Bare Copper cc W J W 1 TB1 O > ¢ .�� Black W ¢ 0 ¢ Q 3 Z Q White 0 O > O O O J • o- u_ O LL w o Incoming Power 1 2 0- a o- o 0- > W p a •Illfrom z � � p j � > > ¢ � w CHASIS Service Entrance < c� d o- 0 o- > LL II GROUND ; : Panel. '� 000 ©©00 EI „ : [al �_a . •• • Branch Circuit • �• - - •-- :• 120/60/1�0 Amps ' • ••' W/Short Circuit ALARM FLOAT ••.. •••' Current RATED 120/60/1 VAC, ••• •• rating of 5kA rms 1 AMP MIN (BLACK) ���" .......�..,.. ■••••• - -', symmetrical (WHITE) (BLACK) OVERRIDE I FLOAT " (WHITE) RATED 120/60/1 VAC, 1 AMP MIN \ BLACK) (WHITE) PUMP FLOAT AERATOR RATED 120/60/1 VAC, UL APPROVED 1 AMP MIN RATED 120/60/1 VAC (BLACK) FLA-5 AMPS MAX. THERMALLY PROTECTED (WHITE) (BLACK) FILTER FLUSH SOLENOID PUMP REDUNDANT OFF FLOAT UL APPROVED RATED 120/60/1 VAC, .,........ • (WHITE) RATED 24 VAC 15 AMPS MIN (BLACK) PUMP UL APPROVED (BLACK) HELD DRAIN SOLENOID RATED 120/60/1VAC, 1/2 HP MAX, UL APPROVED THERMALLY (WHITE) RATED 24 VAC PROTECTED Notes for field installed components: 1. Main Disconnect, Branch Circuit Protection,wiring and external components to be provided by installer. 2. Field wiring-#12—#10 AWG, 60°C min, use copper conductors only. 3. Field installed conduit fittings must be rated for use with Type 4X Enclosure. If used, metal conduit fittings must provide means to bond conduit to ground terminal. 4. Torque Terminal Block, Neutral and Ground screws to 15—20 in-lbs. 5. Conduit openings must be sealed around wiring with an electrical grade(non-corrosive)sealant to prevent potentially harmful vapors from entering the control panel. O&M Page 51 Z9 abed VIVO ® I_N z� _ I g r LINE — • b ? I °� v ALARM \ b\ b POWER • • • ) ) ) 0 0 0 7 o ALARM w • n COMPn Q X PUMP/OVRD FLOAT POWER lull 1 0 PUMP FLOAT C) • 6 Z Z OVRD FLOAT HJ1 °� . - X • 0 n I 1 1 • - r . to PUMP Z G) r rn a- - 1 VALVE POWER ILI FILTER FLUSH VALVE ----- FIELD DRAIN VALVE I-1 TROUBLESHOOTING NOTE: Power must be on to test horn and alarm light. Alarm Horn Pressing the alarm test switch,turning the compressor circuit breaker OFF,or activating the alarm float should turn on the alarm horn. If the horn does not sound, replace with horn of same type. Alarm Li2ht Pressing the alarm test switch, activating the alarm float,or turning the compressor circuit breaker off should turn on the alarm light. If the light does not activate, replace bulb with the same type. Circuit Breakers Check the circuit breaker for proper resistance reading using the following procedure. 1. With power OFF, isolate the circuit breaker by disconnecting the load side wires. 2. Place the ohmmeter leads across the corresponding line and load terminals. 3. With the ohmmeter on the R X 1 scale and the breaker in the OFF position,the reading should be infinity (very high resistance). With the breaker in the ON position, the reading should be nearly zero ohms (very low resistance). If the readings are not as stated, replace the circuit breaker with one of the same ratings. NOTE: Readings may vary slightly depending on the accuracy of the measuring device. Air Switch If lamp and horn are on and pump in pump tank is performing normal: 1. Disconnect air line at fitting at bottom of control panel and feel for air coming out of line. 2. If air supply is normal,then air switch is malfunctioning. Replace switch through manufacturers stock. 24 Hr. Clock Timer Clock not running 1. Check for input power to the control panel. 2. Check all terminals for secure connections. 3. Check breaker for on position. 4. If no circuit fault is evident, replace clock. Clock may be obtained through manufacturers immediate stock. Pump Test Switch Switch not working 1. Turn OFF power. Disconnect both leads to the switch. 2. Connect one test lead from an OHM meter set on RX1 to one post on the pump test switch. 3. Connect the other lead from the same OHM meter to the other post of the pump test switch. 4. Pull on the toggle of the pump test switch. Note: The meter needle should deflect across the entire scale. If the needle does not deflect or O&M Page 53 reads open,replace the switch with one of the same type and rating. Test/Mute Switch Switch not working. 1. Turn OFF power. Disconnect all leads from the test/mute switch. 2. Connect one lead from an OHM meter set on RX1 to the center post on circuit 1. 3. Connect the other lead from the OHM meter to the lower or second post in circuit 1. A. With the toggle in the off or mute position there should be no deflection of the needle on the OHM meter. B.With the toggle in the center position,the needle on the OHM meter should deflect across the entire scale. C. By pulling the toggle into the"test"position the needle on the OHM meter should stay in the full deflection position. 4. Disconnect both leads from the switch 5. Connect one lead from an OHM meter set to RX1 to the center post of circuit 2 on the"test/mute" switch. 6. Connect the other lead from the same OHM meter to the lower or second,post of circuit 2. A. With the toggle on the off or mute position there should be no deflection of the needle on the OHM meter. B. With the toggle in the center or normal position there should be no deflection of the needle on the OHM meter. C. By pulling the toggle into the "test"position, the needle on the OHM meter should deflect across the entire scale. NOTE: If results other than those just described are attained,replace the test/mute switch. Float Controls Check the floats throughout their entire range of operation. Clean,adjust,or replace damaged floats. Check the float resistance - The float resistance can be measured to determine if the float is operating correctly or is defective. Use the following procedure to measure the float resistance: 1. Isolate the float by disconnecting one or both of the float leads from the float terminals. 2. Place one Ohmmeter lead on one of the float wires, and the other ohmmeter lead on the other float wire. 3. Set the ohmmeter dial to read ohms and place on the RX1 scale. With the float in the OFF position the scale should read infinity (very high resistance). Replace the float if you do not get this reading. With the float in the ON position the scale should read nearly zero (very low resistance). Replace float if you do not get this reading. NOTE:Readings may vary slightly depending on the length of wire and accuracy of the measuring device. O&M Page 54 CAUTION: IT IS IMPORTANT TO CONNECT LINE(1) IN THE JUNTION BOX TO THE H.W.A.(1) IN THE CONTROL PANEL AND LINE(2) IN THE JUNTION BOX TO THE H.W.A.(2) IN THE CONTROL PANEL. INSTRUCTIONS FOR Chlorine EWDS (Early Warning Detection System) 0 Patent Pending ©q Support Junction Box !! PP At Pump Tankf.I‘. Cor� Drop Tube y m,_ I � -A, c \ w 0 \I U 'lidm�Ar�nht �l m N Chlorine/Aids ll C N D I T TOa 0 U f- BOTTOM OF o CONTROL PANEL a. [-.... ! Control ,,- ; 1 Panel I Tr- ..=w_ ; H.W.A. 1 . LI FLOAT 1 1 Terminal Block#2 lllll l l l l 11 I I I I ��' dil 1 / i i W tx _ ' 0 2 o w a Cl. g W O . I i O a O a O 1 1 i REREiEiR ! 1 L all 1 I6......�.r I 1 • I Low of•IIIiIIIIIIIillli 1i1 Sending Chlorine Unit DIAGRAM # 2 O&M Page 55 AERATOR SPECIFICATIONS tiqua Safe®aerators for use with all models: All aerators listed are 115 Volt, 60 Hertz and Single Phase Models: AS500,AS500-5 Pre,AS500-5 Pump, AS500-4+75,AS500EZ AS500 TRIO,AS500CU,AS500-300, AS500+5 pre,AS500+5 pump,AS500-300CU Aqua Safe®500 gpd Designation -ASC2532 HiBlow Model HP80- Linear- 2.0 amps/76 watts/ 3.9 CFM open flow SECOH Model EL80-15 -Linear-2.6 amps/ 106 watts/3.4 CFM open flow GAST Model RVO3 - Rotary—3.0 amps/ 120 watts/3.8 CFM open flow Model AS600, AS600CU,AS600-300,AS600EZ; AS600 TRIO Aqua Safe®600 gpd Designation -ASC3342 HiBlow Model HP80-Linear- 2.0 amps/76 watts/3.9 CFM open flow SECOH EL80-17 - Linear- 1.8 amps/ 131 watts/4.6 CFM open flow GAST Model RVO3 - Rotary—3.0 amps/ 120 watts/3.8 CFM open flow Models AS750,AS750EZ Aqua Safe® 750 gpd Designation -ASC3352 SECOH Model EL 100 - Linear- 2.5 amps/ 174 watts/5.3 CFM open flow GAST Model RV05 - Rotary—3.0 amps/ 120 watts/4.8 CFM open flow "''glow Model HP120- Linear- 2.1 amps/105 watts/5.6 CFM open flow Model AS1000,AS1000EZ Aqua Safe® 1000 gpd Designation -ASC5082 SECOH Model EL 150 - Linear- 3.6 amps/262 watts/9.7 CFM open flow GAST Model 0823 -Rotary - 8.6 amps/700 watts/7.2 CFM open flow HiBlow Model HP150-Linear-2.1 amps/ 125 watts/6.4 CFM open flow Model AS1500,AS1500EZ Aqua Safe® 1500 gpd Designation -ASC7510 HiBlow Model HP200- Linear-4.3 amps/225 watts/ 8.3 CFM open flow GAST Model 1023 - Rotary - 10.0 amps/950 watts/ 10 CFM open flow SECOH Model EL200 -Linear- 5.2 amps/350 watts/ 11.6 CFM open flow O&M Page 56 EAST Spare Parts HP SERIES GJL, GJH SERIES UPPER •� -COVER HOUSING �� /Cover ,ti \ is --- --0 j i Cover Gasket FILTER-, 1,, Filter COVER 2.< % GASKET � aa .,,�/ 0,444 • ~ ` ,N. �Upper Housing • , i44iF,ILTERHEAD , ASSEMBLY ^ K 41I1;II' S4N.-• ''\ , 1 i ;' �� Filter �� i'C:� Head \ `i '..a DIAPHRAGM/ 6,.4 '(,, '� I '!/ ASP SAFETY Assembly 'r� , _Ay R`/ 1 RING I _ DIAPHRAGM �� • SWITCH I,` \\ t a+'•^'^!"�_lI' DIAPHRAGM/ / 90 n` \4 e, CASING /i: �� ���Diaphragm till'-;-1- Ring %'1'JJ / .' 7%1 1 Diaphragm � i V # ' !. ' . (61° r." 0, 4* Orra9m / . Ilk tl, / =,,, . - • o 00 -P!* 4 $4 r . r. ;,...., O DESCRIPTION 80GJL 150GJH,200GJH HP100 Q. K FILTER PAD K701 K702 K631 HEAD ASSEMBLY K621 K711 K652 m cn — DIAPHRAGM ASSEMBLY K620 K710 K653 SAFETY SWITCH BAR/SCREW NA K703 K654 EXPLODED PRODUCT VIEW, PARTS & ORDERING INFORMATION REF DESCRIPTION QTY RV03-101 RV05-101 1 BODY 1 AK504 AK500 10 U/1 1 2* VANE 4 AH850A AH850A 9 3 SHROUD 1 AK502B AK502B fatiat/ ' 8 ti 6 . 4 END PLATE 1 AK501 AK501 `' I/ 5 5* GASKET 1 AK521 AK521 1 6 MUFFLER BOX 1 AK519 AK519 / 7* 0-RING 2 AK473 AK473 7 1 i 1 8* FELT 2 AK524 AK524 * 14 0 ill 9 END CAP 2 AK510 AK510 � 2 ''1 � 10 END CAP FILTER 2 AK526 AK526 ASSEMBLY41 ` 11 FILTER I MUFFLER 1 B343B B343B 12 FOOT SUPPORT KIT 1 AC136 AC136 3/ / , // i lir,4111, fft:-.:,-, 13 FELT SUPPORT 1 B347 6347 1 17 goti. oJf N 14* FELT FILTER 2 B344A B344A p 0, d 15 SCREEN CAP 1 AJ571 AJ571 r 16 ROTOR 1 AH775B AH775B 1 '���4LL.�JJ�' 17 TOLERANCE RING 1 AF105 AF105 }` SERVICE KIT 1 K882 K882 s i Intake Filter * Denotes parts included in the Service Kit. Parts listed are for stock models. Assembly ** No Service Kit available, order parts separately. For specific OEM models, please consult the factory. When corresponding or ordering parts, please give complete model ..1 r, 12 9 pd serial numbers. , , JD 14 tv "' ft)14 ETI OWNER'S MANUAL 4" Submersible AQUA SAFE, High-Pressure Effluent Pump Ecological Tanks. inc. Downsviile, LA 71234 ETI AQUA iSAFE. If % installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1 -318-644-0397 O&M Page 59 PRINTED IN U.S.A. 1000000510(01/31/02) TABLE OF CONTENTS tape when sealing joints in plastic pipe. Safety Instructions 2 Warranty is void in the following conditions: • Water is highly corrosive. General 2 • If entrained gas or air present in water being pumped reduce the Electrical 2-3 flow and cause cavitation(which can damage the pump). Operation 3 • Pump has been operated with discharge valve closed (severe internal damage will result). Troubleshooting Guide 4 ELECTRICAL Warranty 4 Carefully read and follow all safety instructions in this manual WIRING/GROUNDING or on pump. AWARNING Can shock, bum, or cause death. Permanently AThis is the safety alert symbol. When you see this symbol Hazardous ground pump, motor and control box before on your pump or in this manual, look for one of the following voltage connecting power supply to motor. signal words and be alert to the potential for personal injury! Ground pump and motor in accordance with all codes and ordi- A DANGER DANGER wams about hazards that will cause seri- nances that apply.All wiring must meet National Electrical Code and ous personal injury,death or major property damage if ignored. Canadian Electrical Code (whichever applies). Use copper ground A WARNING wire at least as large as wires carrying current to motor. WARNING warns about hazards that can cause Motor is supplied with copper ground wire.Splice to copper conduc- serious personal injury,death or major property damage if ignored. tor that matches motor wire size specified in Table 2. Use only cop- A CAUTION CAUTION warns about hazards that will or can per wire for connections to pump. cause minor personal injury or property damage if ignored. Permanently ground pump and motor before connecting power The word NOTICE indicates special instructions which are impor- cable to power supply. Connect ground wire to approved ground tant but not related to hazards. first,then connect to equipment being installed. To avoid serious or fatal personal injury and possible property Do not ground to a gas supply line. damage,carefully read and follow the safety instructions. Float switches or any other approved motor control must match 1. AWARNING Under certain conditions,submersible pumps motor input in full load amperes. Hazardous can develop extremely high pressure. Install For more information,contact your local code officials. pressure a pressure relief valve capable of passing entire pump flow at 75 PSI. INSTALLATION WIRING INSTRUCTIONS ADo not allow pump, piping, or any other system compo- Single Phase, 2 Wire nent containing water to freeze. Freezing may damage 2-Wire pumps have two power supply wires (Red/Black) and one system,leading to injury or flooding.Allowing pump or system ground wire(Green). components to freeze will void warranty. 1.Fasten power supply wire leads securely to pump discharge sec- 2 AWARNING Can shock, burn or cause death. To avoid tion; leave 4-5" of slack in leads at this point. Securely fasten leads to plastic pipe within 6"of the pump discharge section. Hazardous dangerous or fatal electric shock hazard, use voltage pump only in an effluent system. DO NOT 2.Ground wire must be as large as wires supplying current to install pump in an open body of water ( a motor. Consult current National Electrical Code or Canadian lake,swimming pool,etc.). Electrical Code (as applicable) and local codes for grounding information. AInstall, ground and wire pump according to local and Cana- 3.Use only submersible power supply wires supplied by pump man- dian Electrical Code or National Electrical Code requirements ufacturer.When installing pump,secure supply wires to discharge 1 that apply. pipe with Scotch #33 electrical tape. DO NOT damage pump ADisconnect electrical power supply before installing or servic- wires. ing pump. NOTICE: To avoid dropping pump or damaging wires or splices, 1 AMake sure motor nameplate voltage and frequency match NEVER allow pump wires to support weight of pump. line voltage and frequency of power supply. EFFLUENT APPLICATIONS 1.Install pump according to all plumbing, pump and well code Effluent applications must meet the following: requirements. 2.Install an all leg disconnect switch in the power supply near the AWARNING Risk of electrical shock. Do not remove cord and pump. strain relief.Do not connect conduit to pump. 3.Two-wire motors are equipped with automatic thermal overload 1.Only qualified personnel should install the pump and associated protection which will open the circuit and stop the motor when a control equipment. thermal overload (excessive heating) exists. When motor cools, 2.Vent sewage tank according to local code. overload will reset and motor will restart automatically. This can 3. Do not install pump in any location classified as hazardous by cause the motor to start unexpectedly and without warning. National Electrical Code,ANSI/NFPA 70-1984. GENERAL 4.These pumps are intended for permanent connection only. Provide strain relief at control box for power supply cord connec- Inspect pump and motor for delivery damage. Report any damage tion to box.All control components must be UL listed and suitable immediately to shipping carrier or to Aqua Safe®immediately. for end use application. Have any installation, repair, or service work done by your Aqua Safe® PUMP INSTALLATION dealer. Never run pump dry. 1.Make sure that pump and motor are free to rotate by turning the NOTE: Install pump in the effluent or pumping chamber of vault— shaft by hand. NOT in the sewage chamber.Pump is designed to pump filtered 2.To prevent dropping pump, lower it by the drop pipe, not by the effluent or clear water only.It is not a sewage pump. cables.The electrical cables will not hold the pump weight. During system operation,pump must be submerged at all times. 3.Discharge outlet is 1-1/4"NPT threaded. Pipe joint compound can cause cracking in plastics. Use only teflon O&M Page 60 NOTICE: Pump discharge is left-hand thread into pump shell. If OPERATION installing external check valve,hold discharge with pipe wrench to 1.The pump must be submerged at all times during normal opera- prevent loosening discharge in shell. tion.Do not run pump dry. 4. If pump is to be operated with an open discharge, a discharge 2.Make sure that the float switches are set so that the pump stops valve must be installed."Before startup,open this valve about 1/3 before the pump runs dry or breaks suction. If necessary, adjust open.Start pump. Slowly open valve until the desired flow rate is float switches to achieve this. reached. Final setting must be within pump's recommended oper- ating range. 3.The motor bearings are lubricated internally. No maintenance is required or possible on the pump or the motor. Table 1: Recommended Fusing Data 60 Hz/1 Phase 2-Wire Cable Motor Winding Max Locked Fuse Size Voltz/Hz/ Resistance Load Rotor Standard/ HP Phase Ohms Amps Amps Dual Element 1/2 115/60/1 1.4-1.6 10.5 33.4 35/20 Table 2: Power Supply Wire (Cable) Length in Feet 1 Phase,2 Wire Cable,60 Hz (Copper Wire Size-Service to motor) Volts HP 14 AWG 12 AWG 10 AWG 8 AWG 6 AWG 4 AWG 3 AWG 2 AWG 1 AWG 0 AWG 115 1/2 100 160 250 390 620 960 1190 1460 1780 2160 NOTE:Sizes given are for copper wire. For aluminum wire go two sizes larger (i.e., if table lists #12 copper wire, use #10 aluminum wire.) Motor Insulation Resistance Readings Normal Ohm/Megohm readings for all motors, between all leads and ground. Set ohmmmeter to 100K scale. Condition of Motor and Leads Ohm Value Megohm Value New motor,without power cable 20,000,000(or more) 20.0 Used motor,which can be reinstalled in tank 10,000,000(or more) 10.0 Motor in Tank—Readings are Power Cable plus Motor Do not pull pump for these reasons: New Motor 2,000,000(or more) 2.0 Motor in reasonably good condition 500,000 to 2,000,000 0.5-2.0 Motor which may be damaged or have damaged power cable 20,000 to 500,000 0.02-0.5 Pull pump;replace pump or cable: Motor definitely damaged or with damaged power cable 10,000 to 20,000 0.01-0.02 Failed motor or power cable Less than 10,000 0-0.01 Important Electrical Grounding Information A WARNING Hazardous voltage.Can shock,burn, pump housing,or an equipment-grounding lead.The equipment- or kill.To reduce the risk of electrical grounding lead,when provided,will be the conductor having green shock during pump operation,ground and bond the pump and insulation;it may also have one or more yellow stripes. motor as follows: C.Ground the pump,motor,and any metallic conduit that carries power A.To reduce risk of electrical shock from metal parts of the assembly cable conductors.Ground these back to the service by connecting a other than the pump,bond together all metal parts accessible at the copper conductor from the pump,motor,and conduit to the ground- tank top(including metal discharge pipe,metal tank top,and the ing screw provided within the supply-connection box wiring compart- like).Use a metal bonding conductor at least as large as the power ment.This conductor must be at least as large as the circuit conduc- cable conductors running down the well to the pump's motor. tors supplying the pump. B. Clamp or weld(or both if necessary)this bonding conductor to Save these instructions. the grounding means provided with the pump,which will be the equipment-grounding terminal,the grounding conductor on the O&M Page 61 3 TROUBLESHOOTING GUIDE PROBLEM CHECK CORRECTIVE ACTION Motor will not start but fuses do not blow No voltage. No voltage at disconnect switch. Replace blown fuses or bad cable,reset circuit breakers. Electrical cable bad. Consult licensed electrician or serviceman. Fuses blow or overload protector trips when motor starts Wrong size fuse, Check fuse or circuit breaker size against chart,Page 2. Install correct fuse,time delay fuse,or circuit breaker. time delay fuse. or circuit breaker. Wire size too small. Check wire size against chart,Page 3. Install correct size wire. Low or high voltage. Check that line voltage is within±10%of nameplate If voltage variation is greater than±10%.call power rated voltage while motor is running. company or local hydro authority to adjust voltage. Pump or motor stuck or Check for locked shaft in pump. If necessary,pull pump(make all possible above ground binding. checks first).If pump is locked,replace it.Clean tank of all sand,lime,and solids before reinstalling pump. Power supply wires or Consult licensed electrician or qualified serviceman. Have a qualified serviceman or electrician make motor leads grounded, necessary cable repairs. shorted,or open. Fuses blow or overload protector trips when motor is running Low or high voltage. Check that line voltage is within±10%of rated nameplate If voltage variation is more than±10%,call power voltage while motor is running. company to adjust voltage. High ambient(atmospheric) Check temperature of tank Protect tank from direct sunlight. temperature. Wire size too small. Check wire size against chart,Page 3. Install correct wire size. Pump starts too frequently Leaks in system. Check plumbing for leaks. Level switch. Check for defective switch or switch out of adjustment. Re-adjust or replace level switch. Check valves leaking. Make sure check valves are not leaking back. Replace check valves if necessary. Little or no water delivered Check valve stuck. Examine valve. If stuck,free valve. Low voltage. Check voltage at circuit breaker with pump running. Install larger wire from meter to circuit breaker.Install Check incoming wire size and power supply wire size larger wire from circuit breaker to pump.If necessary, against chart.Page 3. have power company raise supply voltage. Plugged intake screen. Pull pump and check condition of screen. Clean or replace as necessary. Check valve at pump Pull pump and examine check valve. Free check valve. discharge stuck. Worn impellers and Make sure system is clear of obstructions and pump is in Replace pump. diffusers. solid water and operating normally. Pump doesn't develop Check pump curve against operating conditions. Replace pump with"higher head"pump. enough pressure("head"). Plugged impellers. Pull pump. Replace pump. O&M Page 62 INITIAL SERVICE POLICY The local dealer/installer from whom you purchased your Aqua Safe®wastewater treatment plant is responsible for routine inspections for the first two years from the original date of installation. The plant will be checked for proper operation at each inspection. If a problem exists, service shall be performed at no charge to the owner unless the required maintenance is not warranty related. These service call/inspections shall include at least four inspections over the two year period and shall include the following: 1. Adjustment of the electrical control, if applicable, and servicing of the mechanical component parts to ensure proper function. 2. An effluent quality inspection consisting of a visual check for color,turbidity, scum overflow, and an examination for odors. 3. Immediate notification to the owner/warrantee in writing of any improper observation which cannot readily be repaired. This notification will or shall advise said owner of the problem, if it is covered by warranty and estimated date for correction of said problem. Pumping of sludge build up from the treatment plant, if necessary, IS NOT INCLUDED in the initial service policy. An annually renewable service policy affording the same coverage as the initial service policy is available. Consult your local dealer for pricing information. O&M Page 63 LIMITED WARRANTY Ecological Tanks,Inc.,Aqua Safe®(hereinafter identified as manufacturer)warrants each aerobic wastewater treatment plant to be free from defects in workmanship and materials from the date of installation by an authorized dealer/installer for the following periods: Manufacturer warrants system aerator for a limited prorated 5 year period thus: First two years - 100%, 2nd to 31-d year- 75%,3`d to 4th year 50%and 4th to 5 year period 25%of manufacturers list price. Third,fourth and fifth year limited prorated portion of this warranty applies only if system owner carries a continuous maintenance policy in full effect and proof is provided with return. Electrical controls, float switches and application pumps are warranted 2 years.Manufacturer warrants fiberglass tanks to be free from defects in material and workmanship for a limited period of 5 years, concrete and metal tanks: limited 2 years from date of installation. When properly installed and registered with the manufacturer,the manufacturer's sole obligation under this limited warranty is as follows: To repair or exchange any components, F.O.B. factory, that in the manufacturer's judgment is defective,provided that said component part has been paid for and is returned through an authorized dealer,prepaid. The warrantee must specify the nature of the defect in writing to the manufacturer. The limited warranty makes no provision for any informal dispute settlement agreement. The limited warranty does not cover any aerobic wastewater treatment plant that has not been properly installed,damaged due to altered or improper wiring or overload protection,flooded by any external means, disassembled by any unauthorized person, filled with anything other than normal household wastewater or damaged by an act of nature. The limited warranty does not cover damages or defects caused by ants, insects or rodents to any component part of the aerobic wastewater treatment plant. No warranty is made as to the field performance of any system. The limited warranty applies only to the aerobic wastewater treatment plant itself and does not include any of the purchaser's plumbing, drainage and/or disposal system,house wiring or installation of the plants. The manufacturer reserves the right to replace any component part covered under this limited warranty with a component part, which in manufacturer's judgment is equivalent to the part replaced. The manufacturer claims no responsibility for any delays or damages caused by defective components or materials which cause losses incurred by interruption of service or for repairs or replacements of component parts covered by the limited warranty. O&M Page 64 MANUFACTURER'S WARRANTY REGISTRATION CERTIFICATE It is the authorized dealer/installer's responsibility to fill out the registration certificate and mail it within 30 days of installation to the address below. The owner/purchaser should verify that this is done to insure proper registration for warranty purposes. ECOLOGICAL TANKS,INC. 2247 HIGHWAY 151 NORTH, DOWNSVILLE, LA 71234 OFFICE: 318-644-0397 FAX: 318-644-7257 PLEASE PRINT AQUA SAFE®PURCHASER'S RECORD Serial# Model# Installation Date Installer's Name Mailing Address Phone AQUA SAFE®INSTALLER'S RECORD Serial# Model# Installation Date Owner's Name Physical Address/City Phone AQUA SAFE®REGISTRATION CERTIFICATE (Must be returned to manufacturer) Serial# Model# Installation Date Owner's Name Physical Address/City Phone Dealer's Name Mailing Address Phone Installer's Name Mailing Address Phone O&M Page 65 f orR The "UV Disin ect o By Ecological Tanks, Inc. Installation, Operation and Maintenance Instructions System Description: The UV system disinfects the effluent by exposing it to a powerful ultraviolet light in a confined space. A flow restrictor ensures that the effluent is exposed to the UV light for a sufficient period of time to complete the disinfection process. A control panel is provided that supplies power to the UV system and has an audible/visible alarm that activates if the bulb fails or the UV current drops below a minimum level. The control panel is housed in a weatherproof enclosure and has separate circuit breakers for the UV system and the alarm system. A layout of the system is shown in Figure 1. Caution: During installation and servicing make sure that power is disconnected from the system any time the UV bulb is exposed. The majority of the energy emitted by the bulb is invisible and is powerful enough to burn eyes and skin in a very short exposure time. Ensure that during installation and service that no fingerprints or oily materials are left on the bulb. If necessary,the bulb can be cleaned with a soft cotton cloth soaked with alcohol. Installation: Mount the UV unit as close to the pump tank as possible(or inside the pump tank). It is advisable to remove the UV lamp before installing this unit. The unit shall be installed in a vertical position. Make sure the inlet connection is level to the outlet side. (A 1/4" vent hole may be drilled into the inlet 90 for pressure release if tank settling is expected.) The inlet 4" 90 is not cemented in place to allow for final alignment. After alignment has been completed cement 4" 90 in place. The riser shall be at ground level when the unit is completely backfilled. Cut off the bottom end of the 6"riser making sure not to cut end with electrical penetration.After cutting end off, glue in place. Do not glue cap. The electrical connector(in the 6 x 4 reducer) should not be flooded. 1 O&M Page 66 Electrical: Mount the electrical panel provided by manufacturer as close to UV unit as possible. Pull the open end of the 40 feet direct burial wire through the hole in the side of the 6"riser(top of UV unit). Do not add more wire to the 40 feet. Bury the wire underground from the unit to the electrical control panel,cut to length. Connect the two wires to the terminal strip in the panel. Connect the power side of the control panel to the 120 VAC source from the house or main system control panel. Do not turn on the power from the house or main control panel until the installation and wiring is complete. Make sure all connections are watertight including the electrical penetration through the 6"riser. Operation: The system will operate continuously without intervention other than scheduled maintenance. If the alarm activates,the homeowner should contact their service provider. Maintenance: When doing maintenance/inspection(every six months)remove cap,unplug and slowly lift lamp out of the unit by pulling straight up on electrical cord. Carefully wipe clean the quartz crystal,then gently slide the lamp back into the unit until the top seal on the lamp is next to the 7/8"hole. Plug lamp back together and replace cap. Every two (2) years replace the complete lamp. It comes with the quartz crystal and lamp in place. Just remove as above and replace. When inspecting,check for settlement in bottom of unit and flush with water hose if necessary. 2 O&M Page 67 Figure 1. System Layout CONTROL PANEL I �J GL GROUND LEVEL DIRECT BURIAL CABLE PRETREATED DISINFECTED EFFLUENT EFFLUENT FLOW RESTRICTOR (INTERNAL) UV BULB (INTERNAL) L I Copyright Notice All information contained on this page is proprietary to Ecological Tanks,Inc. and no part of this information may be reproduced, stored in a retrieval system or transmitted in any form or by any means, electronic, mechanical,photocopying,recording or otherwise without the prior written permission of Ecological Tanks, Inc.. 3 O&M Page 68 Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews,NC 28105 Phone:704-847-3031 mikel(a,LashEngineering.com Lash Engineering, Inc. John Henessey NPDES Permitting Program Division of Water Quality Raleigh,NC. 27699-1617 Re: UV Light Analysis UV lights of a low flow nature are typically a low-pressure type, short wave, mercury vapor discharge tube that produces ultraviolet wavelengths lethal to microorganisms. The low pressure allows the units to run with less power and thereby generating less heat for longer life of the bulbs. The Aqua-Safe UV"Disinfector(Model TUD)"Light has been specified for this project. Different microorganisms are extinguished at different doses. The larger"pests"take longer. Fecal Coliforms are extinguished at near 6600 µWs/cm. This lamp has a range up to 30,000 µWs/cm. Although there is a wide spectrum of bacteria,viruses and protozoa, most of the"pests" are extinguished between 2,000 and 20,000. Having a range up to 30,000 µWs/cm, assures that the germicidal action is most effective across this wide range. For this application, fecal coliforms are most important,which have a dose requirement of about 6600 µWs/cm. This is well within range. The Aqua-Safe UV Light has been submitted for review because of its ability to be installed in the vertical or horizontal position. It clearly has the UV qualifications to be effective. The requirements for vertical placement are spelled out in the installation guidelines with a warning to ensure the power head is above the water line. The power unit cannot be submerged. This note has been added to the plans. This unit is acceptable for use in this application and is accepted for use on this project. Ecological Tanks, Inc. uses a germicidal preheat bulb that is rated for 10,000 hours of functionality combined with a ballast that is strong enough for instant startup. In the 1.5 gallon treatment chamber the UV output is rated at 2,470 mw/sec/sq. cm at 65%transmittance. Calculating a three gallon per minute free-flow rate (i.e. 30 second exposure time),the UV exposure measures 74,100 microwatt/second doses(30 seconds x 2,470mw/sec on disinfected effluent.After 7,500 hours of operation UV output may drop 20%. This would indicate doses of 59,280 mw/sec (20%of 2,470mw/sec= 1,976mw/sec x 30 seconds). However,the"UV Disinfector" system contains a flow restrictor that the UV bulb rests in to ensure a maximum dosage of effluent during peak use times. The controls current sensor is designed to signal an alarm when the current of the ballast dips below a nominal operating threshold. Sincerely, Michael Lash,PE. O&M Page 69 • • a C TOP VIEW 88" 20"RISER AC eBASE ACCESS COVER VENT AERATOR COVER 33" III 1 FG IdBER { 19" 1 1 I 4 " 4"INLET OUTLET SOIL GASKET 4"SDR X DWJ COUPLING 98" 81" 92" 89.5" SIDE VIEW LitSI Fd'IION: ueaoOS..� MODELAS1100L EZ TTrm.n1CptllF 1100 GPD Row Line*Law 1965GAL WYC REF.DTh1100 [REV:0 IRATE:08'12/200E ISGILE.FLL1 ENG:ACE ' ECOLOGICAL TANKS,INC HORaralNSORNMONvecNmou�. 3347 HWY 151 NORTH SOREOM nREITOPM. a ae DIMI'45 HIE.LA 71234 ar No . O&M Page 70 3166440197 OFFICE 3166147257 FM M1mRN M.RAISSY Of M.O..WW1 PG CONTROL PANELS AND ALARM A Division of Ecological Tanks Inc. 2247 Hwy 151 North,Downsville,LA 71234 (318)-644-5480 The UV Disinfector (Model TUD) Bulb Efficiency Information Ecological Tanks, Inc. uses a germicidal preheat bulb that is rated for 10,000 hours of functionality combined with a ballast that is strong enough for instant startup. In the 1.5 gallon treatment chamber the UV output is rated at 2,470 mw/sec/sq cm at 65% transmittance. Calculating a three gallon per minute free-flow rate (i.e. 30 second exposure time), the UV exposure measures 74,100 microwattlsecond doses (30 seconds x 2,470 mw/sec) on disinfected effluent. After 7,500 hours of operation UV output may drop 20%. This would indicate doses of 59,280 mw/sec (20% of 2,470mw/sec = 1,976mw/sec x 30 seconds). However, the "UV Disinfector" system contains a flow restrictor that the UV bulb rests in to ensure a maximum dosage of effluent during peak use times. The controls current sensor is designed to signal an alarm when the current of the ballast dips below a nominal operating threshold. CONTROL PANEL It I It II! IIII II NNW GROUND LEVEL I W DIRECT BURIAL CABLE M S- Ital -� N III IICI Nc PRETREATED me ■'■ --J DISINFECTED EFFLUENT �'y EFFLUENT LOW RESTRICTOR (INTERNAL) UV BULB (INTERNAL) iHp NOTE: Image above depicts a ground installation.The system is compatible with interior tank installations. Copyright Notice: All information contained on this page is proprietary to Ecological Tanks,Inc.and no part of this information may be reproduced,stored in a retrieval system or transmitted in any form or by any meanMeRierrat, mechanical,photocopying,recording or otherwise without the prior written permission of Ecological Tanks,Inc. MU BK.203 N S V p 9 BK.2B3 iJ N 61ro6'E414hi n¢ 91 PG.174 /A 30. , ` ' \ -mot A I 1 \� I ENE 1 Da. DdS1MG(9ARi£1D \ I \ \ /ervvsAKer 4A t• soROA g5POsAl I C. / / ADJACENT PSRMPOUFRTY Is ro I1E ABA2OUwD.4b xis LL' \ i DIVING DRAW FIELD BP / \ a I PROPOSED 1000g ,�, / Y\ / SEPTK TAN( W�\ A / \ q..\ / S PRETREAT wTN Y\\ �Gf 1d3 \ !nII,IIIL'INlfill. UV ,he l� FS51111D 0N 6�506 \ `.� i J� SF►11L'T / u e \ PROPERTY UN£SETBACKS OF 59 CAN NOT BE NET. CLASuiveY COUNTY;ONE PARCEL Cf LAND.. \--... ti v I `\`� USING 5O SETBACKS WOULD EXCLUDE EASING CREEK. TAX PARCEL/58200615136 I.O90. Bk1263/Pg.174 �, // 2 Mdrev 51 CCNIPASS CREEK DR.;HMESVALE,NC. 25904 y / ( A' . \ THE 1005ETBACK OFF THE CREEK CANNOT BE YET. 3.AL CORNERS ARE LPNI0)UNLESS OTHERWISE NOTED. is:,. \ ` \\ IlL IS'FONDATCN S SNOYN. 1.AL CORNERS WERE RECENTLY RUGGED Wp S• \ R£WATER WELL IS 60'FRO/THE EJXSTING SEPTIC TAW AM THE AOIASAFE 5.AL DISTANCES ARE HORIZONTAL DISTANCES UNLESS OTHERWSE NOTED. WBY•. 'Ji• .{ \ \\\ki,\ \ iA \ PRETREAT UNIT. 6.AREAS BY GIS DISTANCE d BEARING PER SURSEY. DISCHARGE LOCATOR \\\ , yRK9IT WAS C 7.PROPERTY S RECYND SIK7IN pR NOT�SIOM.CEABLE FAalMN1S.RESIRIC710NS d,� .*a4 \ B SUI5ECT PROPERTY IS RAT RATEIAR IN A 00749 0J00 HAZARD AREA AS Y��"4OEILRIMED PR ROOD IS NOTCE RARE SO 13A 5/COAg0OJ. Q,� \� 9.MS LOT IS NOT LOCATED SAWN AN EXISTING SUBDIVISION Cf LAND. O44 \\ \ Y1y_CiS \ ll 10.WATERS£D TOPO WI:SHRED ERMA NC.00T IG 1RAF19ADED 10 PLANS \ J JA 11.POTABLE WATER IS SUPPIAED BY AN COSTING CNSITE WATER METER AS SHOWN OR W.IS'SEIBACN OFT \\\ JY \ \ TYE RAMS. 1 BUILDING WAS BAT IN I96a t7H---' HOUSE FOINDATION. CR51NG CREEK FLOWS YEAR ROUND. ,�' \ \\ y \ 1.NO1RY ILL AVGD PLANTING TREES WMN 7(Y OF TANKS OR PIPING OF m+�YY WASTEWATER SYSTEM. '\ > 2 GRADE AROUND UNITS SHOULD DRAIN STORMWAIER AWAY FROM TANKS * I I 3 ALL PIPE TO BE SCH.40 PVC.(GLUED JOINTS), — 44''tltl 4.ALL PIPE TO HAVE WATERTIGHT CONNECTIONS. likkilik � S CONTROL PANEL IS TO MONITOR UV AND AOUASAFE UNIT. IN CASE OF L) its„/ \ FAILURE THE SYSTEM IS TO SOUND ALARMS. LASH N/0'32'W \\ l AP w N ENGINEERING '� THE SETBACJ(REI]UNEMENTS FOR A DRIP SYSTEM ARE APPLICABLE TO Con.... 'iLens 21.54' I I1 1.09tACRES \`1,/ �� TNIS SYSTEM THE SETBACK REQUIREMENTS FOR A SPRAY SYSTEM Pn4'! Lor+A N ) WLL NOT BE USED. YI/ h .. / 20M812'W51 ISA NucnT.NRf SETBACKS/ / NC 40 Pa.IN / -/ l (a)lia esWads kr Flplbn saw rial M w Idiom. RmwNuwen C-]AW/ 5a Gryh..../ ICOBETBACK OFi // •�cVMY neMweN r.leerh«a IAaw oI paw auarar rise ewaoU.naWhW (+«)(I.t) o /` C}� _l not to De mowlairee w pst of 1M pmjwi Ale Alb j&S rN/ (;, a Mr Wm11We rams a Mos al park awenOlr owed tY M pwmKlw4\ / MY PKcleto be maittaimd as a park cols emsart a pro}cl rie1 115 _3 e Surface wtee(meow-Mama.and men.,perennial.m.rma a 6+trxL�'cc V N arammemmom ���iii+++ vM.etlaMs) 1 Too W V�l ` vraew I 0 aarnd.lot loerswi dlcnw(Anse ins Behan a no diM Marmots to NWT)I Tao R W ��•£ 1 '•� 0� •M a.wwpikn Seem vats Men*c acti eeleakonerd s,salereap,Ma) 25 1 250 rROlvr h qoJ' .MY 4!229.Awe 1 II MIQRA tr wMMarrreewerw 1 ` w 1 t) I Tee al MN ai mea,EmwN a ww or 1.Net a mac w wnm nNy�t +5 MIGAAEL LASH.P.E. werwweMrree n I My eala I. Nan o Mama spleen _ M wa.gaMder lamMg Crone eplms 1 I10 ••r N y aeInmina 1 1W -ro+ •• •• S 1wwr-ww.reew I J a Phalle�l of r Sa 01111i ;",r.wrr.,..,�,.r, wmmaat Awe 15 w^^e'e -�•e•r'rr •Mr Niacin foundation a basement 2 Rt1YW Wt WWw11rpAB.s. MS4',Re91 m •Setbacks for the We one slam in Pion. 011. 1111 I) 3 SEIBACX REDUWEMENT3 i I arm hors N 4 • I.Rime eater Well 250'WIRES P9551m jIatlWlwedw.amn I y Mb 2 Fwnesnon Ea Solana 15' 15' Property Ma(halt a R/Y} 5a 20. a! I .Property Line(rear): 1ANSIww+aMY FaCsly Wr. 5 Me (re In pv raab) RIMW btlt () 1 m sM Nmroso.ao. BRAND A lna naves.awe IawUon,wklvg wptk AS ae w metingdeWM.1.w.N .I No NMmrntale for Me loco.of the treatment salts 1 BK.444 B.Name locator set to sad wleroc.Alp ewer. Non.SSNC.•CloyCote 1 PG.171 C.See*.Kiss eR be reeked for TS/w1Y.fiBWlslse PrivetsYaler WO 25WreairS sefi0'owWk Fronf Property lies 50'ram.va 2a'powRHe awC�IOA a Ith CICreek ICO'marred vs 21.61.l. �t T SSYSTEY DISCHARGE WASTEWATER m cf ARu41YQSQf MIA 1WRI61t9r ,r.weeammenar M M 9111DTCA SIM&OMR s.w r-v zo W NM S��1e 20 9111.. 1 OF 2 MooEE 224 CONSTRUCTION SEQUENCE A N>�•�a ow.n n=n m.i,.+M 571131 NOES .e.va.0 .,d w.r r,,,xw7wm t t IIILJI I.NATE TO EINSTALLEDREQUIRED) ED) PEA STOW WED.18 A 11M PLIN s i0 SNOW THE LOCATION MID DEOPN 7 ME P { sue- _ EXISTING USE: I DDIAM/INC Rt V REBMED) WASTEWATER MIN MO gPOYl HE1D ONLY CR All OREA IL 1 - 2 USE NAME IEEE FOR BAODAI wM W DRDAN05 IDWOWEXIS CONSULT THE AACWIECI OR OVER ®a _: 1ASOVAf[LINE S TO BE NSTAILD BETDW FROST DEPTH N A Yes 11— EXISTING 8 BEDROOM HOUSE PROPERLY PLACID AND NfACTED.KEEP MUTTON N 1 ELECTRICAL COMM,WNW MO a6TAUADON S 10 BEN «' I�� FREE Of WA.Al ALL TAES Cbi•aeMR MN THE[LECnxCAL[M(. 7... __ I S e-F fu N e'LETS IIMEE L MUST BE ABLE 10 A 9 �, - \11 GILL-7 BEMFN WALLS Of TANK.f4 1 SOES iw$i, ___.—_� 4 MM WE NLWEADS .�WNW_ 1 _ FI111 L WWI BIADML SNEIALL COMPACTION WR4WICIg1 LADIES h ^• " '+�..,...... j S N� �, .... i �111�II REQUIRED FLOW CALCULATIONS: 2 St L I- S 9DEl1ILL CONRESSOX 4 ESSENTIAL RR MEWL Siff 5 EASBY ACQ558f fOC LNDAOwG A EXCAVATED ['m +•. II 'L�II® •�y_T:,y I e BEDROOMS%120 d.=860 RESTRµi. EgmMS ME TDOYPO ST BE wslDum USE.AN EACAVAONC NT �•,W _ _ e.eAacnu eElxEnl RISERS FIRST.COMPLETE eApnlwxc, HI SYSTEMS un mlwmwrz SHALL a INSTALLED IN AccaRDM1a NTH �r.RrruA.r V .�.� D B iva ROM DRAINAGE AWAY FROM LAwI. ALL.CONSTRUCTION ITIP DEALT M9 ACCORDMANUFA NIEFS INSTRUCTIONS. ."TY .. II -®ate• �T^ — =T �' 1_jk e��P� TOTAL FLOW FOR SYSTEM.9B0 9Dd Not[ uwREAcnaIVE,O c NEN APPROM7 1877MANUFACTURERSw1176 _ _ I.All.ihYl'J,Q AXO CONTROL PANELS ALLLL E SECURED REPRESENTATIVE,OR MEN IPPxOIfD RfTMfcxiAnlf. \ L� "V. O :�'0 NTH LOCKS 1 77071 CONTR..4 NOT TO CESTADDE 7677 SLOPE 2 77 SHALL M SLOPED NM OMER AND SERWQ A.MPS CAE NO.1S TO H IBA1VDFE0. TIC COSIES WDL AS ," —_ T_ REAESENTAnIE. SHORE(M PLAN 4 MR A APPLY(f DOESLE wAmL �r'�• a°"� 6 �^ 1 uerro ,— 3.6 ND NAME A DATABLE 11 MAMMAL 6 N®f0 NOT SUITABLE MAUPFD MR FIL-THEN 8IINTAUFR 6 SYS.IS ID DOKIRST AE NW0EY ME A8E a MSTAl1NC M4 SYSTb. mme. ,D a MomemoGw eN.T EZTOP.W RAB LDu,nclL .,....�.� lor'� N.L.awr.mew 4'CHECK VALVE `\\ / \/ \ �'—.ms.TW . 19AYIAQUA SAFE CONTROL PANEL AM (......__10.0 it 'T .x� I �ENL�E '�-- --yam i ANYI� --r-j-e f! 0 El to e ,.._ Raw Cr W. x » O fro X S I/1(� \\ Tow. NEI. OPRENFS E AND RAPPER. 1 W�" Lli I.ONTED wM NETAL BACKINGHEAVY sSTANLESS STEEL STEEL RIVET J.REDUCES MOTOR DE LASE D PUMP NOISE ++ YROM PLUMBING STEEL CLAMPS FaxLOW PRESSURE BOw11NFi0 % i"i GE STRESS ti 23 ill C.�CaxNA, �AIIEL'OC \ . //^\ \ wwM.NN NTG 4 AWA SAFE . \ .- .f _ i� xFaix'NM8A2a0D1 CONTROL Mw"'"°NN,w,"„n — _ �-•,.- -----1v- - .mw:mmr6.""*"wWml NAM oTe MO w Non A®o �' ILLIWITI WET ( • // \ \ / DIPICT WEAL • F lU56 19 11� 11�11 N9wEDEn >' \\ gu �O \\ \\ ,` � I P�Ex.� DILUENT \\ \ \ ' \ \ PPS (NmaALT \ \ �O /p \ MICHAEL LASH,PE NESTINOTOR .WIIEEN.L Cr AT1C PPE m E SET\\ /� lilt", � AT 1S ABM wVRT OF CREEK \\ \ 'CA' •,W„.nnwu.u�.o® STONES ^ s 01 PROa uo rxEcuTlmmalm \\\ \ �/s Y/^/� RIchod Bock .......... �4•N� MODEL FEUD �Q, �� \ \\ \\ 9,,, Ups TO BE 3'l0 8'ABOVE (nm¢N oaN GRADE.GRADE GROUND TO O. \ \ \ A��FACILITY LEN.=20.,.0 SLOPE AWAY FROM UNITS. 0 O \\ \\ \ p nLiooa.A.w� / 10p (-woo moo amBAN \ \ \ PAom, "k�R P DISIN0 C6aEM 0 \ \ \ NMwwal'wr racily/01: \ \K ill Capsf..171. • Na•\we.NC•Ow Cave, MAGI SOK LARGE �� %l.D...55�m15154 PM.cownorro7m GOM PROPOSED 1000R SEPTIC TANK >sNA aO9O'ro°1m'6' crnrv"crop m nrlo Nmrr Properly Thee ore from a referenced sumo Durhq MetdMbn CONTRACTOR i0 COORgNAiE NTH DIRECT dNSCIIAR(f WASTEWATER ,:., mow oAc'eot OP ER ON TRANSFERRING OVER TO THE " 1C 607 ALk eee elevation. Theme moat be allleael j;Mat eM,len•N function oe 1REA71ENT MIEN 2081.w. A�rl . Se ma0 to Narero Unit and tD Oy a creek. hom House NEW WASTEWATER SYSTEM CND ABANDONING WASTEWATER DOSING EM SYSTEM. TOWS/WORSHIP SCHEMATIC LAYOUT(LAYS) aNORTH CPROLPIA OLD glum M rn > N """ee®q a 1.800.632.4949 TOT STMIE\a•^ 2r NO MMwANA,GWL 7.MIER TO D AD 20 CONCRETE BLOCK Pow. c -�m�-���: 61482 Scale 1"=10' 2a2