Loading...
HomeMy WebLinkAboutNC0025496_Authorization to Construct_20010628NPDES DOCUMENT SCANNING. COVER SHEET .a► ANN NPDES Permit: NC0025496 Lincolnton WWTP Document Type: Permit Issuance Wasteload Allocation i._ Authorization to Construct (AtC) Permit Modification Complete File - Historical Correspondence Speculative Limits Instream Assessment (67b) Environmental Assessment (EA) Permit History Document Date: June 28, 2001 Tizis document is printed on reuse paper - ignore any content on the reirerse side jaPirA WCDErR Michael F. Easley Govemor William G. Ross, Jr., Secretary Department of Environment and Natural Resources Kerr T. Stevens Division of Water Quality June 28, 2001 Mr. Jeff Emory, City Manager City of Lincolnton P.O. Box 617 Lincolnton, North Carolina 28093-0617 SUBJECT: Authorization to Construct ATC No. 025496ACB City of Lincolnton Lincolnton WWTP Lincoln County Project No. CS370456-04 Dear Mr. Emory: A letter of request for Authorization to Construct was received by the Division and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 6 MGD Lincolnton Wastewater Treatment Plant, with discharge of treated wastewater into the South Fork Catawba River in the Catawba River Basin. This authorization results in no increase in design or permitted capacity and is awarded for the construction of the following specific modifications: Modifications to the influent pump station including the replacement of existing pumps with one (1) 3125 GPM pump, and two (2) 6250 GPM pumps; modifications to the influent screening structure to provide a new mechanical bar screen with screening wash, compactor and manual bar screen bypass channel; a dual vortex grit removal system; the construction of a new concentric oxidation ditch with four (4) 50 HP rotors to replace the existing primary clarifiers and trickling filters; installation of fine bubble diffused aeration in the existing aeration basins; two (2) new 100-foot diameter 14-foot sidewater depth secondary clarifiers to replace the existing clarifiers; a new return sludge pump station with dual 90 HP submersible pumps controlled by VFDs; a new chemical storage and feed building with sodium hypochlorite feed equipment, sodium bisulfite feed, and acetic acid feed; a new chlorine contact tank; modifications to two (2) existing anaerobic digesters to include new mixing equipment, two (2) new floating digester covers, one (1) new floating gas holder cover, and heat exchanger equipment; a new 12-foot by 65-foot dissolved air flotation thickener; modifications to generator Customer Service Construction Grants & Loans 1633 Mail Service Center Raleigh, NC 27699-1633 (919) 733-6900 1 800 623-7748 FAX (919)715-6229 Internet Address: www.nccgl.net sets G-1 and G-3, plus the addition of a new 750 KW generator set G-4 with automatic transfer switches; a 5673 square foot laboratory building all associated yard pipe, site work and electrical work. This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NC0025496 issued July 24, 1995, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0025496. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the North Carolina Division of Water Quality. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Mooresville Regional Office, telephone number (704)663-1699, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, the Authorization to Construct the approved plans and specifications. Mail the Certification to Cecil G. Madden, Jr., P.E., Construction Grants & Loans, DWQ / DENR, 1633 Mail Service Center, Raleigh, NC 27699- 1633. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified :back-up operator of the appropriate type and grade to comply with the conditions of Title 15A, Chapter 8A, .0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III and IV facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of Title 15A, Chapter 8A, .0202. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and, when applicable, the North Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division of Water Quality in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. One (1) set of approved plans and specifications is being forwarded to you. If you have any questions or need additional information, please contact Cecil G. Madden, Jr., P.E. at telephone number (919) 715-6203. Sincerel Kerr T. Stevens Director CGM:dr cc: Pease Associates Lincoln County Health Department Mooresville Regional Office, Water Quality Section Technical Assistance and Certification Unit Daniel Blaisdell, P.E. Dave Goodrich, NPDES Permitting Unit Cecil G. Madden, Jr., P.E. SRF " ° CITY OF LINCOLNTON WWTP ATC No. 025496ACB ENGINEER'S CERTIFICATION I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the modifications and improvements to the Lincolnton WWTP, located on North Carolina Highway 150 in Lincoln County for the City of Lincolnton, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following construction: Modifications to the influent pump station including the replacement of existing pumps with one (1) 3125 GPM pump, and two (2) 6250 GPM pumps; modifications to the influent screening structure to provide a new mechanical bar screen with screenings wash , compactor and manual bar screen bypass channel; a dual vortex grit removal system; the construction of a new concentric oxidation ditch with four 50 HP rotors to replace the existing primary clarifiers and trickling filters; installation of fine bubble diffused aeration in the existing aeration basins; two (2) new 100-foot diameter 14-foot sidewater depth secondary clarifiers to replace the existing clarifiers; a new return sludge pump station with dual 90 HP submersible pumps controlled by VFD's; a new chemical storage and feed building with sodium hypochlorite feed equipment, sodium bisulfite feed, and acetic acid feed; a new chlorine contact tank; modifications to two existing anaerobic digesters to include new mixing equipment, two (2) new floating digester covers, one (1) new floating gas holder cover, and heat exchanger equipment; a new 12-foot by 65-foot dissolved air flotation thickener; modifications to generator sets G-1 and G-3 plus the addition of a new 750 KW generator set G-4 with automatic transfer switches; a 5673 square foot laboratory building all associated yard pipe, site work and electrical work. I certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and specifications. Signature Registration No. Date Mail this Certification to the Cecil G. Madden, Jr., P.E. Construction Grants & Loans DENR/DWQ 1633 Mail Service Center Raleigh, NC 27699-1633