HomeMy WebLinkAboutCarteret_Well Abandonment_20220817 (4) WELL ABANDONMENT RECORD For Internal Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS Thomas J. Benthall, Jr. 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30 its needed. Indicate TOTAL NUMBER of 4508-B wells abandoned:NA NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): 1'82 (gal.) Eastern Carolina Environmental Services, Inc. FOR WATER SUPPLY WELLS ONLY: Company Name 7c.Type of disinfectant used: NA 2.Well Construction Permit#: N/A List all applicable well construction permits(i.e.UIC,County,State,Variance,etc)ifknown NA 7d.Amount of disinfectant used: 3.Well use(check well use): Water Supply Well: 7e.Seating materials used(check all that apply): ❑Agricultural ❑Municipal/Public ❑Neat Cement Grout @ Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout j ❑ Dry Clay ❑Industrial/Commercial ❑Residential Water Supply(shared) @ Concrete Grout ❑ Drill Cuttings ObTigation ''-: ' " ❑ Specialty Grout ❑ Gravel Non-Water Supply Wei ❑ Bentonite Slurry ❑Other(explain under 7g) @Monitoring very Injection Well: - 7E For each material selected above,provide amount of materials used: ❑Aquifer Recharge R lcc VftWr Remediation approx.25.4 Ibs (0.3815 cu.ft) Bentonite Chips ❑Aquifer Storage and fi•CeriLery Ol/i;ajB(3jGalinity Barrier ❑Aquifer Test ❑StormwaterDrainage approx. 12.5 Ibs. Concrete Grout ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer Tagged well depth;Poured bentonite chips in well from bottom to the ❑Geothermal(Heatin Coolin Return) ❑Other(explain under 7g) top using a 1.5"diameter tremie pipe at a rate of about 2 Ibs.per minute 4.Date well(s)abandoned: 7/21/2022 using a funneling device and hydrated bentonite with potable water; 5a.Well location: placed concrete grout in well vault around wellhead Town of Emerald Isle Incident No. 16270 Facility/Owner Name Facility ID#(i£applicable) 8.Certification: 7500 Emerald Drive 7/22/2022 Physical Address,City,and Zip Signature o Contractor or Well Owner Date Carteret 539306390689000 By signing this form, I hereby certify that the wells) was (were)abandoned in County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: i (ifwell field,one lat/long is sufficient) 9.Site diagram or additional well details: 34.66730 N -77.02770 µ You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction record(s)ifavailable.For multiple injection or non-water supply wells ONLY with the same construction/abandonment,you can submit one form. 10a. For All Wells: Submit this form within 30 days of completion of well 6a.Well ID#: M W-4 abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 17.50 (ft) 1617 Mail Service Center,Raleigh,NC 27699-1617 10b.For Infection Wells: In addition to sending the form to the address in 10a 6c.Borehole diameter: Not Known (in) above,also submit one copy of this form within 30 days of completion of well abandonment to the following: 6d.Water level below ground surface: 6.15'from TOC(ft.) Division of Water Resources,Underground Injection Control Program, 1636 Mail Service Center,Raleigh,NC 27699-1636 6e.Outer casing length(if known): 0.50 (ft.) 10c.For Water Supply&Infection Wells: In addition to sending the form to the address(es)above,also submit one copy of this forth within 30 days of completion of well abandonment to the county health department of the county where 6E Inner casing/tubing length(if known): NA (ft) abandoned. i 6g.Screen length(if known): 17.00 (ft.) i i Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016 z 0 z \ I 0 a O F— ITa-' a I Q WV) LLJ 0 W 'dU30wQ cD c� W J a. >Z zaZ J wZ I LLJ w o 0 0 Z W o3 p � I0 H N 3 0 C IJ z W FE O a 0 U~ I I LLJ w = Z —� tY I 0 W 0 iL (AWC �= W Q a N Z d W m Z J 0 w I " O 0 i QO M0to w I z �'U N f— I� Lal z Qw I(x m a r- w LL N W a�� w iN OwN a I a O�Na I W W_jL,0 I W J Q d Fat I G 35�0 o I 6 N(n—col W N I F ]GC CL 00 33 3 Z I 0 I m;d W QO J I Y 2 a 0 N a I 0 m ®114 ate W Q w I x c CL p m I N W Q I I a a 0 : I a I 4, s I z o W 0 w I W C Y Lo a U Q M Z I In J I a 00 W I I � W i VI I 0 I I ' I : I I N 0 � 2 � J D13.' J COZm�N Z Yp r aZ cn U • I I • I ' I I • Y I ' W I Z w I w U IZ U la Z U W I O In a Z s I �^ a w_j CXi i0 Q IIn ONnOdOAVId a m , � I I • � I E I r WELL ABANDONMENT RECORD For Internal Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS Thomas J. Benthall, Jr. 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30'is needed. Indicate TOTAL NUMBER of 4508-B wells abandoned:NA NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): 2'1$ (gal.) Eastern Carolina Environmental Services, Inc. FOR WATER SUPPLY WELLS ONLY: Company Name 7c.Type of disinfectant used: NA 2.Well Construction Permit#: N/A List all applicable well construction permits(i.e.U/C,County,State, Variance,etc.)ijknown 7d.Amount of disinfectant used: NA 3.Well use(check well use): Water Supply Well: 7e.Sealing materials used(check all that apply): ❑Agricultural ❑Municipal/Public ❑ Neat Cement Grout a Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout i ❑ Dry Clay ❑industrial/Commercial ❑Residential Water Supply(shared) a Concrete Grout ❑ Drill Cuttings OIrrigation ❑gSecialty Grout ❑ Gravel Non-Water Supply Well: Re tonite Slurry ❑Other(explain under 7g) IlMonitoring ❑Recovery f Y, C !� Injection Well: /^�II�''( 2� f f.For each material selected above,provide amount of materials used: tAW 11 / ❑Aquifer Recharge ❑Groundwater Re of approx. 29.1 IbS(0.436 CU.ft) Bentonite Chips ❑Aquifer Storage and Recovery ❑Salinity Barrier �r0.�.�„,}� ❑Aquifer Test ❑Stormwate>1�a naig ;�tscPProx. 12.5 Ibs. Concrete Grout ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer ❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) Tagged well depth;Poured bentonite chips in well from bottom to the top using a 1.5"diameter tremie pipe at a rate of about 2 lbs.per minute 4.Date well(s)abandoned: 7/21/2022 using a funneling device and hydrated bentonite with potable water; 5a.Well location: placed concrete grout in well vault around wellhead Town of Emerald Isle Incident No. 16270 Facility/Owner Name Facility ID#(if applicable) 8.Certification: 7500 Emerald Drive 7/22/2022 Physical Address,City,and Zip Signature of ifie ell Contractor or Well Owner Date Carteret 539306390689000 By signing this form, /hereby certify that the wells) was (were) abandoned in County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (ifwell field,one lat/long is sufficient) 9.Site diagram or additional well details: 34.66722 N -77.02741 W You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction records)ifavailable.For multiple injection ornon-water supply wells ONLY with the same construction/abandonment,you can submit one form. 10a. For All Wells: Submit this form within 30 days of completion of well 6a.Well ID#: M W-3 abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 20.00 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617 10b.For Infection Wells: In addition to sending the form to the address in 10a 6c.Borehole diameter: Not Known (in) above, also submit one copy of this form within 30 days of completion of well abandonment to the following: 6.40'from TOC Division of water Resources,Underground Injection Control Program, 6d.Water level below ground surface: (ft) 1636 Mail Service Center,Raleigh,NC 27699-1636 6e.Outer casing length(if known): 10.00 (ft.) 10c.For Water Supply&Injection Wells: In addition to sending the form to the address(es)above,also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where 6E Inner casing/tubing length(if known): NA (ft.) abandoned. 6g.Screen length(if known): 10.00 (ft.) i Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016 FFm W z W F— N� L?0 3 i- r7 �' H 0 W J � I Z Z z a z ,� -� w Z I O N W J W w J pN 2 3 03 0 I �_~ � QJ Z Li (Az W o a V~ 1 9 Q W W Z JJ W I V) WJ �+- � 0 wow �N W I z (Y= OWJ W o W I o O N z 0 NQ I OZ M30W 8 ® 0x In �a �� ai � � W I� m L 0 0 r w W j� 1 0) N W 0 W Q w I(A � N ix _jLf)z I 4 V 3 N a I W C J V I W �Ha WF-C I n_ c 30 �o c a Hcc X� � N a� � ui z 2 3 z I W Wg< oar c _ � I Y {z`� D V v0 0 W I C J 0 >. m I04 cc 3 I m haw I x a N W Q I a 4 I a I V s t+1 ( C O I W VI I c Y : W I a U Z I H m : I a ix w I i D 3 NLLJ I a L I 3 I � I � I I I : I I N o � z � Y �Jn0 Q iZ O Z N U im IIII a • I I • I ' I • I I • Y I • W I Z w U : w 1 Iz U Z� W Ic N Q Z a w� P 1ix ~- Q 10 N ONnodoArd a m , y