Loading...
HomeMy WebLinkAboutNC0025879_Authorization to Construct_20150115NPDES DOCUMENT SCANNIN` COVER MEET NPDES Permit: NC0025879 Robbinsville WWTP Document Type: Permit Issuance Wasteload Allocation Authorization to Construct'. (AtC) Permit Modification Complete File - Historical Report Speculative Limits Instream Assessment (67b) Environmental Assessment (EA) Permit History Document Date: January 15, 2015 This document is printed on reuse paper - ignore any content on the rezrerse side JP06 Town of Robbinsville Robbinsville Wastewater Treatment Plant Wastewater Treatment Plant Relocation A To C No. No. 025879A02 Issued February 28, 2012 Engineer's Certification I, i) a v cic Lyyr. 1-�' , as a duly registered Professional Engineer in the State of North Carolina, hdving been authorized to observe (periodically/ ) the construction of the modifications and improvements to the Robbinsville WWTP, located at the corner of OId Hwy 129 and Knight Street, Robbinsville in Graham County for the Town of Robbinsville, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following construction: Construction of anew dual -train 0.63 MGD wastewater treatmentplant, with each train consisting of a 85,000 gallon flow equalization zone with dual 2,7 Hp submersible mixers and dual 550 gpm pumps, two (2)) 6 3..6 gallon anaerobic zone with each zone having a 3 Hp submerged mixer, a)'fl,500 gallon pre -anoxic zone with dual 3 Hp submerged mixers, a 2.6%400 gallon aeration zone with coarse bubble diffusers, dual 1,312 gpm internal recycle (NRCY) pumps, a 53,125 gallon post -anoxic zone with a 3 Hp submerged mixer, a 4,430 gallon re -aeration zone, a 37-foot diameter clarifier, an airlift WAS pumping system, a 93,000 gallon sludge digester/storage tank with coarse bubble diffusers and decanter; three (3) 327 gpm RAS pumps; three (3) 1,625 scfm blowers (2) automatic backwash disc filter units; backwash pumpgati}ticonsisting of dual gpm pumps; a dual bank UV disinfection system with each bank rated for 1.58 MG ultrasonic flow meter; I6-inch ravity outfall to new outfall in Cheoah River; a laboratory/office building; kW standby generator; and associated air and yard piping, electrical control systems, in conformity with the project plans, spe ati , and other supporting data subsequently filed and approved by the ____ D'epartment of Environment and Natural Resources. r certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and specifications. Signature Registration No. () 3 y 999 Date VI SAS. Mail this Certification to: Attn: Joseph Gyamfi, P.E. Tnfrastructure Finance Section DENR/D WQ 1633 Mail Service Center Raleigh,, NC 27699-1633 t-Ca-1k -lg\Q Ci (S2) d'S?c- 14;e1." ttttttttttttttttttttttttttt ttttt I..: i ;1' -g -'4O'`Cd'G!Ne, , ), f ern NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Wakild, P.E. Dee Freeman Governor Director Secretary February 28, 2012 The Honorable Bobby Smith, Mayor Pro-Tem Town of Robbinsville P. O. Box 129 Robbinsville, North Carolina 28771 SUBJECT: Authorization to Construct A to C No. 025879A02 Town of Robbinsville Robbinsville WWTP Relocation Graham County Dear Mayor Smith: • A letter of request for an Authorization to Construct was received October 4, 2011, by the Division of Water Quality (Division), and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 0.63 MGD Wastewater Treatment Plant, with discharge of treated wastewater into the Cheoah River in the Little Tennessee River Basin. This authorization results in no increase in design or permitted capacity and is awarded for the construction of the following specific modifications: Construction of a new dual -train 0.63 MGD wastewater treatment plant, with each train consisting of a 85,000 gallon flow equalization zone with dual 2.7 Hp submersible mixers and dual 550 gpm pumps, two (2) 26,560}gallon anaerobic zone with each zone having a 3 Hp submerged mixer, a 80,500 gallon pre -anoxic zone with dual 3 Hp submerged mixers, a 244,250 gallon aeration zone with coarse bubble diffusers, dual 1,312 gpm internal recycle (NRCY) pumps, a 53,125 gallon post -anoxic zone with a 3 Hp submerged mixer, a 4,430 gallon re -aeration zone, a 37-foot diameter clarifier, an airlift WAS pumping system, a 93,000 gallon sludge digester/storage tank with coarse bubble diffusers and decanter; three (3) 327 gpm RAS pumps; three (3) 1,625 scfm blowers; two (2) automatic backwash disc filter units; backwash pump station consisting of dual 350 gpm pumps; a dual bank UV disinfection system with each bank rated for 1.58 MGD; ultrasonic flow meter; 16-inch gravity outfall to new outfall in Cheoah River; a laboratory/office building; a 600 kW standby generator; and associated air and yard piping, electrical work and control systems, in conformity with the project plans, 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX: 919-807-6492 Internet: www.ncwaterqualitv.org An Equal Opportunity \ Afrmative Action Employer North Carolina Naturally The Honorable Bobby Smith, Mayor February 28, 2012 Page 2 specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NC0025879 issued December 2, 2011, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0025879. • The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the Division. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by the Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Asheville Regional Office, telephone number (828) 296-4500, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to: Infrastructure Finance Section, DWQ/DENR, 1633 Mail Service Center, Raleigh, NC 27699-1633. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of T15A:8G.0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III and IV facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of T15A:8G.0202. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, The Honorable Bobby Smith, Mayor February 28, 2012 Page 3 and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and when applicable, the North Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction, the recipient must have obtained all applicable permits from the State. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. One (1) set of approved plans and specifications is being forwarded to you. If you have any questions or need additional information, please contact Seth Robertson, P.E. at telephone number (919) 707-9175. Sincerely, di Charles Wakild, P.E. jg:sr cc: David Honeycutt, P.E, McGill Associates, 55 Broad Street, Asheville, NC 28801 Graham County Health Department DWQ Asheville Regional Office, Surface Water Protection DWQ, Technical Assistance and Certification Unit DWQ, Point Source Branch, NPDES Program Joe Gyamfi, P.E. AtoC File 025879A02