Loading...
HomeMy WebLinkAbout820188_Routine Inspection_20220803Type of Visit: 0 Compliance Inspection 0 Operation Review 0 Structure Evaluation 0 Technical Assistance Reason for Visit: 0 Routine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access Date of Visit: 0-1.0 / Arrival Time: Farm Name: f (f"N/ n/YNJ/ Owner Name: rn' go...tntf Mailing Address: Physical Address: Facility Contact: riff - Departure Time: Owner Email: Phone: County: Region: a'V �% :Ka Pea; Onsite Representative: Certified Operator: Back-up Operator: Location of Farm: Title: Trd/ra- Phone: rcifit Latitude: Integrator: Certification Number: Certification Number: Longitude: Wean to Finish ® "° Layer 1.1 l ar ut IIIi• tcif • eac i Dairy Cow r n a lit 3 €€ h Wean to Feeder 1,, Non -La er Dairy Calfj. ceder to Finish f Dairy Heifer Farrow to Wean rr y '�p 1u�3,. f' Dry Cow I! Farrow to Feeder t • ftldt °,t „ tl Non -Dairy Farrow to Finish tl - Beef Stocker Gilts -- Non -Layers Beef Feeder Boars -- j j Pullets i Beef Brood Cow Turkeys r# Turkey Poults ]# gg other I Other Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (If yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? d. Does the discharge bypass the waste management system? (If yes, notify DWR) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverse impacts or potential adverse impacts to the waters of the State other than from a discharge? ❑ Yes Q'ICo ❑ NA ❑ NE ❑ Yes ❑ No ❑ NA ❑ NE ❑ Yes ❑ No ❑ NA ❑ NE ❑ Yes ❑ No ❑ NA ❑ NE ❑ Yes 20 ❑ NA ❑ NE ❑ Yes �No ❑ NA ❑ NE Page 1 of 3 2/4/2015 Continued 12. Crop Type(s): 13. Soil Type(s): Facility Number: - - /O D IDate of Inspection: gr,2 Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? ❑ Yes RIo ❑ NA ❑ NE a. If yes, is waste level into the structural freeboard? ❑ Yes ❑ No ❑ NA ❑ NE Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: Spillway?: Designed Freeboard (in): Observed Freeboard (in): 30 5. Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes []No ❑ NA ❑ NE (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a ❑ Yes Q'No ❑ NA ❑ NE waste management or closure plan? If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR 7. Do any of the structures need maintenance or improvement? 8. Do any of the structures lack adequate markers as required by the permit? (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes []'No ❑ NA ❑ NE ❑ Yes [] No ❑ NA ❑ NE ❑ Yes [3 No ❑ NA ❑ NE ❑ Yes Ilffo ❑ NA 0 NE ❑ Yes E \ elo ❑ NA ❑ NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground 0 Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved- Area BidYJlnetal �9vCr5Ytt) lN: s✓�c tdinmre✓A—A" arn—Wia --d-- 4✓, rfr(K 94914DPO 14. Do the receiving crops differ from those designated in the CAWMP? ❑ Yes [i]'No 0 NA ❑ NE 15. Does the receiving crop and/or land application site need improvement? larYt ❑ No ❑ NA ❑ NE 16. Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes IfiNo ❑ NA ❑ NE acres determination? 17. Does the facility lack adequate acreage for land application? ❑ Yes El'i Io ❑ NA ❑ NE 18. Is there a lack of properly operating waste application equipment? ❑ Yes al(o ❑ NA ❑ NE Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes Q No ❑ NA ❑ NE 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes No ❑ NA ❑ NE the appropriate box. ❑ WUP ❑ Checklists ❑ Design ❑ Maps ❑ Lease Agreements ❑Other: 21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes ErNo ❑ NA ❑ NE ❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code ❑ Rainfall ❑ Stocking 0 Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes [XNo ❑ NA ❑ NE 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes dNo ❑ NA ❑ NE Page 2 of 3 2/4/2015 Continued Date of Inspection: 53' 3-2 2 2- 24. Did the facility fail to calibrate waste application equipment as required by the permit? 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the appropriate box(es) below. ❑ Failure to complete annual sludge survey 01Von-compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: ❑ Yes allo es ❑ No ❑ Failure to develop a POA for sludge levels / 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ Yes 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? 34. Does the facility require a follow-up visit by the same agency? ❑ Yes ❑ Yes ❑ Yes ❑ Yes ❑ Yes ❑ Yes ❑ Yes ❑ Yes ❑ NA ❑ NE ❑ NA ❑ NE z ErI o El NA No ❑ NA RNo 1210 Ro ❑ NA ❑ NA ❑ NA all.° ❑ NA ❑ NA ❑ NA ❑ NA ❑ NE ❑ NE ❑ NE ❑ NE ❑ NE ❑ NE ❑ NE ❑ NE ❑ NE 441 r1-4gok- raav(190 fr it e +wt-'- War% Pi trfr e-r✓i % n- Reviewer/Inspector Name: Reviewer/Inspector Signature: Page 3 of 3 Phone: »'0 'l- 0157 Date: 5/12/2020