Loading...
HomeMy WebLinkAboutWQ0005247_Compliance Evaluation Inspection_20220823ItOY COOPER Governor ELIZABETH S. BISER sea Cory RICHARD E. ROGERS, JR. Director NORTHLINA E�nrMr+n:aettaRlOQuality August 19, 2022 Jerry Howerton — Maintenance Manager NC Department of Natural and Cultural Resources 13304 Creedmoor road Wake Forest, NC 27587 Subject: Compliance Evaluation Inspection Permit # WQ0005247 Facility: Falls Lake SRA - Rollingview WWTF/WW Irrigation system Durham County Dear Mr. Mumford: On August 16,2022 Jim Westcott from the Raleigh Regional Office visited your wastewater treatment and irrigation system and met with David Mumford, Vincent Shea, and Joel Valentine to evaluate compliance with the subject permit. Your collective cooperation and comprehensive tour of your facility was informative and greatly appreciated. You are permitted to operate a 9,999 gallon per day (GPD) wastewater collection, treatment and irrigation facility consisting of ten influent pump stations at the Rolling view park; a grit chamber and piping to connect to the existing shower at Pump station 2; a septic tank; a pump station with two 22 gallon per minute (GPM) effluent pumps and high water alarms; approximately 500 linear feet (LF) of 2-inch force main to discharge collected wastewater from the Superintendents' residence to the existing wastewater facilities; approximately 345 linear feet (LF) of 8-inch gravity sewer; approximately 225 LF of 6-inch gravity sewer; a 2 horsepower (hp) pump station with duplex pumps and high water alarms; eight 5 hp pump stations each with duplex pumps and high water alarms (as upgraded); two 7.5 hp booster pump stations (as upgraded) each with duplex pumps and high water alarms; approximately 17,650 LF of 2,3 and 4-inch force main; a 7 million gallon (MG) stabilization lagoon; a tablet chlorinator; a 3200 gallon chlorine contact chamber; a 150 GPM irrigation pump station with dual submersible pumps; two 3.55 acre irrigation zones; and all associated piping, valves, controls and appurtenances with no discharge of wastes to surface waters. North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office l 3800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 The permit, which was issued January 23, 2017, expired December 31, 2021. Section I (1) of the subject permit requires the permittee to request renewal of the permit no later than six months prior to the expiration of the permit on official division forms. At the time of inspection, the permittee presented a receipt of acknowledgement of the application renewal letter by the division dated July 25, 2022. Please ensure that future renewal applications are completed and submitted no later than six months prior to expiration to the division as required At the time of inspection, required logbook, maintenance, flow, calibration records and annual standard soil fertility analysis was available for review. Each lagoon freeboard level was clearly marked, identified, and recorded weekly, including discharge pump run hours and spray application rate(s). The treatment lagoon was secured and proper signage on the perimeter fencing. The two 3.55-acre spray field(s) were in good condition with consistent vegetative cover in each zone. The schedule of application to each of the spray fields is recorded each day to ensure even distribution. Spray nozzles are inspected for proper operation are the facility grounds were clean and structured. Each spray field/zone discharge nozzle(s), piping connections were inspected while on site. A section of the aluminum discharge line on the east side entrance of the spray field had become dislodged from a tree branch and will need to be repaired. The section was secured at the main line with a valve cap to ensure the area is receiving adequate pressure and an even spray -distribution pattern in each zone. 1. OPERATION AND MAINTENANCE REQUIREMENTS: Section I (1) of the permit Monitoring and Reporting requirements state that the facilities shall be properly maintained and always operated. The facilities shall be properly maintained and always operated. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the discharge of any wastewater resulting from the operation of this facility. The permittee shall maintain an Operation and Maintenance Plan, which at a minimum shall include operations functions, maintenance schedules, safety measures and a spill response plan. [15A NCAC 02T .0507] Within 30-days of receiving this letter, please forward a document showing the repaired line and the inspection schedule for the spray field to this office. 2. MONITORING AND REPORTING REQUIREMENTS: Records were not available for the requirements of section 8 [15A NCAC 02T.0108(b)(1)] of the permit regarding residuals disposal. No material has been removed from the site. Records indicating the sludge level in the lagoon were not available at the time of inspection although the previous estimate was two years ago. Within 30-days of receiving this letter, please forward a plan for evaluating the solids levels in the lagoon to this office. North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 11611 Mail Service Center 1 Raleigh, North Carolina 27699-1611 919 707 9000 3. The non -discharge monitoring reports (NDMR's) for the subject facility were reviewed for the period January 2021 — July 2022, and the following observations were detected [see attached Monitoring Report (MR) Violations Report for details]; (a) Monitoring Violations — The facility reported the following limit exceedances during the 2-year review period: Two CL2 residual and two pH. (b) Reporting Violations — Four Total Nitrogen as N The wastewater treatment system should be periodically inspected to ensure the treatment components are always maintained and in good operating order. You are also reminded to maintain all monitoring data and associated maintenance records onsite for a minimum of three years and available for inspection. Within 30-days receipt of this letter, please submit a written response to this office indicating the actions you will take or have taken to comply with or resolve the issues noted in items 1 and 2 above. The office will address the monitoring report violations under a separate cover. If you have questions or comments about this inspection or the requirements to take corrective action (if applicable), then please contact Jim Westcott at tames.westcott!ancdenr.gov or (919- 791-4247). Sincerely, Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Attachment(s): Compliance Inspection Report Staff Report Cc: Laserfiche North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 11611 Marl Service Center I Raleigh, North Carolina 27699-1611 919.707.9000 • • ■ ■ VI■ .■ ■ ■ r • • J� • I. ` I 1 ` ` 1 1 ' All 1 -', 1 r 1 1111 1 I I I lr�, w T1A1 - r.11 . ,1rxt '..= �..1 ,fill I 1 1 I� •■. 1 ly • ■ 1 -■ 1 �11 11 1 11•I ■ II _ •■1 �, III LAl • �IA .A I. I ' ` :� - 1•• 1 '.n_i I..mi • am. .1 . �1 1'' 1 F 1 .11 �11 1 1 1 11 _ ,- ■ - I ly ik I k - iir. . 1 1 iim I, .. • • "I � 1 1 - , i ii II 1 I 1 • 1• #• 1 �I 1 1 •I I 1 1 1 :: • 1 1. • lii ■ ■ 1 II 1 II : 1 I• ■ N. I • e +. • r •1-. • .a• , , I ji 1 i 1 •• 1 .• 1.0 1 , • ;• r • ••••-1 ora•, ri a• 41EL r . * • 11.1:11 1 .111 • -91W r 1 1 f- L■ • Ell I. I I r - 11 + 11 "i - k • r r 1111111 *40 ■■ • • • _ Wm1 ■ ■ • • • II • 1 Compliance Inspection Report Permit: WQ0005247 Effective: 01/23/17 Expiration: 12/31/21 SOC: Effective: Expiration: County: Durham Region: Raleigh Contact Person: David Mumford Title: Owner : North Carolina Department of Natural and Cultural Resources Facility: Fails Lake SRA- Rolling View WWTF 4201 Baptist Rd Durham NC 27707 Phone: 984-867-8000 Directions to Facility: Six Forks Rd. north to Hwy. 98. West on Hwy. 98 to Baptist Rd. At end of road, tum left onto Boyce Mill Rd. Guard gate is straight ahead. System Classifications: SI, Primary ORC: Christopher E McGee Certification: 1009635 Phone: 919-859-0669 Secondary ORC(s): Vincent Joseph Shea 998524 919-604-3989 On -Site Representative(s): Related Permits: Inspection Date: 08/16/2022 Entry Time 09:30AM Primary Inspector: James Westcott Secondary Inspector(s): Reason for Inspection: Routine Permit Inspection Type: Wastewater Irrigation Facility Status: • Compliant 0 Not Compliant Question Areas: ▪ Treatment Flow Measurement -Effluent • Treatment Flow Measurement -Water Use Records • Record Keeping In Treatment Influent Pump Station (See attachment summary) Exit Time: 11:OOAM Phone: 919-791-4247 Inspection Type: Compliance Evaluation 111 Treatment Flow Measurement -Influent ▪ Treatment ▪ Treatment Lagoons ▪ Treatment Disinfection • Miscellaneous Questions ▪ Treatment Barscreen ▪ End Use -Irrigation ▪ Treatment Flow Measurement Page 1 of 6 penult: WQ0005247 Owner - Facility: North Carolina Department of Natural and Cultural Resources Inspection Date: 08/16/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: At the time of inspection,required logbook, maintenance, flow and calibration records, annual standard soil fertility analysis was available for review. Lift station was clear of buildup and pumps and controls were in good working order. Pump run times are recorded each day. Each lagoon freeboard level was clearly marked, identified, and recorded weekly, including discharge pump run hours and spray application rate(s).The treatment stabilization/faculative and storage lagoon were secured and proper signage on the perimeter fencing and well maintained. The two 3.55-acre spray field(s) were in good condition with consistent vegetative cover in each zone. The schedule of application to each of the spray fields is recorded each day to ensure even distribution. The facility grounds were clean and structured. Each spray field/zone discharge nozzle(s), piping connections were inspected while on site. Page 2 of 6 permit: WQ0005247 Owner - Facility: North Carolina Department of Natural and Cultural Resources Inspection Date: 08/18/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Yea No NA NE Reuse (Quality) ❑ Infiltration System ❑ Single Family Spray, LR ❑ Activated Sludge Spray, HR ❑ Activated Sludge Spray, LR ❑ Activated Sludge Drip, LR ❑ Recycle/Reuse 0 Single Family Drip ❑ Lagoon Spray, LR Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? •❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) •❑ ❑ ❑ Comment: Treatment Influent Pump Station Yea No NA NE Is the pump station free of bypass lines or structures? 11000 Is the general housekeeping acceptable? M000 Are all pumps present? •❑ ❑ ❑ Are all pumps operable? • ❑ ❑ ❑ Are floats/controls operable? •❑ ❑ ❑ Are audio and visual alarms available? •❑ ❑ ❑ Are audio and visual alarms operational? • ❑ ❑ ❑ # Are SCADA/Telemetry alarms required? ❑ ❑ ❑ Are SCADA/Telemetry available? ❑ ❑ ❑ Are SCADA/Telemetry operational? ❑ ❑ ❑ Comment: Treatment Flow Measurement -Influent Yes No NA NE Is flowmeter calibrated annually? U 000 Is flowmeter operating properly? M ❑ ❑ ❑ Does flowmeter monitor continuously? 11000 Does flowmeter record flow? •❑ ❑ ❑ Does flowmeter appear to monitor accurately? M000 Comment: Treatment Flow Measurement -Water Use Records Yes No NA NE Page 3 of 6 Permit: WQ0005247 Owner - Facility: North Carolina Department of Natural and Cultural Resources Inspection Date: 08/16/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is water use metered? Are the daily average values properly calculated? Comment: Treatment Flow Measurement -Effluent Is flowmeter calibrated annually? is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Comment: Treatment Barscreen Is it free of excessive debris? Is disposal of screenings in compliance? Are the bars spaced properly? Is the unit in good condition? Comment: Treatment Disinfection Is the system working? Do the fecal coliform results indicate proper disinfection? Is there adequate detention time (>=30 minutes)? Is the system properly maintained? If gas, does the cylinder storage appear safe? Is the fan in the chlorine feed room and storage area operable? Is the chlorinator accessible? If tablets, are tablets present? Are the tablets the proper size and type? Is contact chamber free of sludge, solids, and growth? If UV, are extra UV bulbs available? If UV, is the UV intensity adequate? # Is it a dual feed system? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- ) 1f yes, then when was the RMP last updated? Comment: • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ■ ❑❑❑ • ❑❑❑ • ❑❑❑ • ❑❑❑ • ❑❑❑ Yes No NA NE ■ ❑❑❑ ■ ❑❑❑ ▪ ❑❑❑ • ❑❑❑ Yes No NA NE ▪ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑❑❑ ■ ❑❑❑ ❑ ❑•❑ ❑ ❑O❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑❑❑ ❑ ❑•❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑•❑ ❑ ❑•❑ Page 4 of 6 Permit: WQ0005247 Owner - Facility: North Carolina Department of Natural and Cultural Resources Inspection Date: 08/16/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Record Keeping Yes No NA NE Is a copy of current permit available? MOOD Are monitoring reports present: NDMR? • ❑ ❑ ❑ NDAR? ❑ ❑ ❑ Are flow rates Tess than of permitted flow? El ❑ ❑ ❑ Are flow rates less than of permitted flow? • ❑ ❑ ❑ Are application rates adhered to? •❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? ❑ ❑ •❑ Are all samples analyzed for all required parameters? ❑ ❑•❑ Are there any 2t. GW quality violations? 0 ❑• ❑ Is GW-59A certification form completed for facility? ❑ ❑ II ❑ Is effluent sampled for same parameters as GW? ❑ ❑ • ❑ Do effluent concentrations exceed GW standards? ❑ ❑ • ❑ Are annual soil reports available? ■ ❑ ❑ ❑ # Are PAN records required? ❑ • ❑ ❑ # Did last soil report indicate a need for lime? ❑ • ❑ ❑ If so, has it been applied? ❑ ❑•❑ Are operational logs present? MOOD Are lab sheets available for review? MOOD Do lab sheets support data reported on NDMR? • ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? ❑ ❑ • ❑ Are Operational and Maintenance records present? •❑ ❑ ❑ Were Operational and Maintenance records complete? • ❑ ❑ ❑ Has pemiittee been free of public complaints in last 12 months? in ❑ ❑ ❑ Is a copy of the SOC readily available? • ❑ ❑ ❑ No treatment units bypassed since last inspection? ❑ ❑•❑ Comment: End Use -Irrigation Yes No NA NE Are buffers adequate? • ❑ ❑ ❑ Is the cover crop type specified in permit? • ❑ ❑ ❑ Is the crop cover acceptable? • ❑ ❑ ❑ Is the site condition adequate? • ❑ ❑ ❑ Is the site free of runoff / ponding? • ❑ ❑ ❑ Is the acreage specified in the permit being utilized? MOOD Is the application equipment present? • ❑ ❑ ❑ Is the application equipment operational? •❑ ❑ ❑ Page 5of6 permit: WQ0005247 Owner - Faclllty: North Carolina Department of Natural and Cultural Resources Inspection Date: 08116/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is the disposal field free of limiting slopes? Is access restricted and/or signs posted during active site use? Are any supply wells within the CB? Are any supply wells within 250' of the CB? How close is the closest water supply well? Is municipal water available in the area? # Info only: Does the permit call for monitoring wells? Are GW monitoring wells located properly w/ respect to RB and CB? Are GW monitoring wells properly constructed, including screened interval? Are monitoring wells damaged? Comment: • ❑❑❑ • ❑❑❑ • ❑❑❑ ❑ ❑1111❑ ❑ ❑N❑ ❑❑M❑ ❑ ❑ . ❑ ❑ ❑•❑ ❑ ❑M❑ ❑ ❑ ❑ Page 6 of 6 0 0 O 0 2 2 1-00 ZZ0Z-CO (N se) Ielol 'ae6oal!N 40 O 0 0 JL N 1 1 1 1 1 1 N N N N IV N N N N N N 0 CD CA CD N i i i Al i O 0 0 0 0 0 (N se) lelol `ua6o llN (N se) lelol 'ua6OJU!N (N se) imol `ue60.11!N 0 0 0 0 0 -a Oro v w .Li CD CD CD CD GO CD CD -I, 0 -3.J i N i S -I.N -1 s -IL lenplsaa Ielol 'euuolgo 0 0 O O CD CD CD CD 0 0 0 2 2 $ 2 2 mmmm mm 'm 3 -, 1 1 a a a a n 6uissi1A1Ja;awemed c3 to 3 3 co 13 sue) 0�1 03 N 3 3 m CD m 0 W m 03 03 03 iA 3 3 3 (0 a CO CO z 0 m AON of Paaoad 6uisslyy Ja;aweJed 6u!sslyy JelaweJed 6ulsslyy JalaweJed 6u!sslyy Ja101118Jed z Z Z 0 0 0 > > > Z Z m 0 m 0 N O W t39. 3 ? 7 w_ `03 m a a 0. 0 0 a 00C m� 0 z 0 C m z 0 z_ C 0 m le m r ij 3dA1 NOIJY1OIA NO110V NOUN-OIA uolleloln bu!podaJ Z cai, 2 2 2 2 m? 0 N N N N N N 0 0 NJ 0 0 0 0 0 XI 2 N N N N 0 0 0 0 0 0 1 ! 1 J lenpisaH len 'auuoIy3 lenplseN I>rlol'auuoiLo VIA A (34 A A A O_ O A O_ o mN N'1.4 CP CD 0 x i x x ID CD x x a< a< a< cn 0 'e .< .< i 2 3 )) 0CS) 0 0 0 C C 4 C S S O 0 0 0 0 0 �". 6) so o.. O O 0 O 0 0 z Z 0 0 D D 0 O m 0 0 O W O 0 3 3 3 3 P3 CD = 0 CD= W i C v m G) r O 0 Z a rn i rn v0a ma z 0 C z 0 { 0 { c O 'n 0 C C) cc m� m v 0 0 z m m N0113Y NOIJY1OIA uolleloi buuolluoyy m 3 9 L$ S000OM 0 5 O 3- 03 3 461elekl :NOI93i1 % :JOUIIN JO!BIN %:eKueN A IIPBd %kUeN =Med Permit WQ0005247 MRs Betweei 1 - 2021 and 7 - 2022 0 co O c 0 0• —. Q w 0 MONITORING REPORT(MR) VIOLATIONS for: Bupsnry Ja;awBJed z 0 -0 0 0 g m 0 0 0 z rn rn 73 ij NOIlOV NOI1V1OIA uogelo!A ouJoaatl 9 LPZSO00DM O C 3 1161011611 :N010311 • % :mum Jofeyy %:BUJBN A11110eA % weN waled 73 0 0 0 0 c m 0 ID cio 7 eE MONITORING REPORT(MR) VIOLATIONS for: CD 0 0 rn 0 co 0 N N m CO CD N O_ IV