Loading...
HomeMy WebLinkAboutWQ0043594_Application (FTSE)_20220627DocuSign Envelope ID: F9467F61-094F4IW91CF-CC373E5D24CC -W Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 06-21 & SUPPORTING DOCUMENTATION Application Number: WO D (to be completed by DWR) NC Dept of Environmental Quality All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Cat of Sanford (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: Paul Weeks per 15A NUAC 02T .Ill M Title: Utilities and Engineering Director 4. Applicant's mailing address: 225 E. Weathers oon Street City: Sanford State: NC Zip: 27331 5. Applicant's contact information: Phone number: 919 777-1122 Email Address: paul.weeks()sanfordnc.net 11. PROJECT INFORMATION: JUL 012022 Raleigh Regional Office ❑ Privately -Owned Public Utility ❑ Other 1. Project name: Elite Storage (Broadway) 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: __, For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Lee 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.4622� Longitude:-79.1377' 5. Parcel ID (if applicable): 9652-92-1997 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Jeff Foster License Number: 028291 Firm: CE Group, Inc Mailing address: 301 Glenwood Ave., Suite 220 City: Raleigh State: NC Zip: 27603-� Phone number: (919) 367-8790 Email Address: jeff(a�cegroupinc.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Big Buffalo W WTP Permit Number: NCO024147 Owner Name: City of Sanford V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ22556 2. Downstream (Receiving) Sewer Information: 8 inch ® Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00047 Owner Name(s): City of Sanford FORM: FTA 06-21 Page I of 5 DocuSign Envelope ID: F9467F61-094F-4160-91CF-CC373E6D24CC VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [:]No ® N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreemcnt (FORM: DEV j been attached? [--]Yes [--]No ® N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/P(:)A Operational A, pe!ment (FUR.t: HOAI and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): ❑ Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ® Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: % Domestic 100 % Commercial _.. % Industrial (Sec 15 q NC C 02t,0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .01141 t)? ❑ Yes ❑ No ➢ If yes, provide a coipy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow "s No. of Units Flow Warehouse — Self Storage I gaWnit 265 265 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC 02T .0l l4().[d}_ (e){ 1.1 and ic1[2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G. S. 42A-4). b Per ISA NCAC 02T .01 14(c), design flow rates for establishments not identified [in table 15A CAC i12T.0l 14J shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: _ GPD (per 15A NCAC 02T.0 1141 ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 DocuSign Envelope ID: F9467F61-094F4160-91CF-CC373E5D24CC VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity, Sewers): L Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 210 DIP ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) D Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01 C.l .b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A Ni'AC. 02T .0305(h)t l ): ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 bocuSign Envelope ID: F9467F61-094F-4160-91CF-CC373E5D24CC IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .03[)5(f) &ice-' ® Yes ❑ No 15A NCAC 02T.0305(f) contains minimum separations that shall be nrnvided fnr sewer cvsremv Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 'Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 'Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water Iines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches y If noncompliance with 02T.0305ft) or (a) , see Section X.I of this application * 5-1 NCAC 02T.0305jg) contains alternatives where separations in 02T.03051f! cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Clag�itications webpa�,e 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N. A ➢ If no, please refer to 15A NCAC 18C.0406(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ❑ Yes ❑ No ®N+A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's tlra eparation tyquirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: ® No If yes, does the project comply with setbacks found in the river basin rules per .15A Nc.'AC 02B .0200? ❑ Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 2B4O202 5. Does the project require coverage/authorization under a 404 Nationwide: individual permits ❑ Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.OI 05(cN6) (additional permits. -certifications)? ® Yes ❑ No Per ISA NCAC 02T_0105(.c)(61 directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 13 A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 DocuSign Envelope ID: F9467F61-094F-4160-91CF-CC373E5D24CC X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimilm Design Cri—ria for the Petm[tiin& o1' Pump Stattow, and Force Mains latest yersionl, and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Annroval of the reauest will be issued concurrently with the a roval of the ipermit, and proiects reouirine a variance aipproval may be subject to longer review times. For tnroiects reauirint< two or more variances or where the variance is determined by the Division to be a si nificant ortion of the pr9jeF1 the full technical review is re uired. 2. Professional Engineer's Certification: I, Jeffrey R Foster Jr attest that this application for Elite Storage (Broadway) (Professional Engineer's name from Application Item III 1 ) (Project Name from Application Item II 1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteri, . fart Gravi!y Sewers (latest versionl, and the Minimum 12csign Criteria. for the Fast-Tra;:k Permitting gMmp Stations and Force Mains flatest ver i n . Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: 0610?12� •� - Applicant's Certification per 15A NCAC 02T .0106(b): I, Paul Weeks attest that this application for Elite Storage (Broadway) (Signature Authority Name from Application Item 13.) (Project Name from Application Item II 1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-21.5.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. EP88C39E55G7844B9 DocuSigned by: $A h. u1UIS Jr. P.f,. Signature: Date: 6/30/2022 FORM: FTA 06-21 Page 5 of 5 DocuSign Envelope ID: DBA7E3B7-342D-4F54-864A-11CA05OF6502 NC Dept ofEDvitonmcntal Quality State of North Carolina JUL 0 12022 Department of Environmental Quality Division of Water Resources Raleigh Regional Offing Tracking for Sewer Extension Applications Division of Water Resources (FTSE 10-18) Application Number: FT-337 Entity Requesting Allocation: City of Sanford Project Name for which flow is being requested: Elite Storage_Broadway Rd More titan one FTSE maybe required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility name: Big Buffalo Wastewater Treatment Plant b. WWTP Facility Permit #: NCO024147 AU flows are in MGD c. WWTP facility permitted flow: d. Estimated obligated flow not yet tributary to the WWTP: e. WWTP facility's actual average flow: 12.0000 1.8010 4.1390 f. Total flow for this specific request: 0.00027 g. Total actual and obligated flows to the facility: 5.9402 h. Percent of permitted flow used: 50% II. Complete this section for each pump station you are responsible for along the route of this proposed List pump stations located between the project connection point and the WWTP. (A) (B) (C) (D) - (B+C) (E)=(A-D) Pump Pump Firm Design Approx. Obligated, Total Current Available Station Station Capacity, Average Current Not Yet Flow Plus Capacity' (Name or Permit Daily Floe Avg, Daily Tributary Obligated Number) Number tFirmintl Flow, Daily Flow Flow 11IGD MGD MGD MGD MGD MGD Kelly . Drive #005 02880 0 1 152 00360 00060 00420 0.0732 Little Buffalo 6 3648 25459 1 3.`146 06602 19648 0.5811 zBig_Buffalo #N:'A #N A #N A MA #NrA #NIA x #Nr'A #N+A #N A #NIA MA MA x #N:A #N.'A #N A #N)A #NrA #NrA x #N A #N.:A #N. A MA #N.'A #NIA I. The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. 2. Design Average Flow is the firm capacity of the pump station divided by the peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. 3. A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is 5 0. Downstream Facility Name (Sewer): City of Sanford Collection System Downstream Permit Number: WQCS00047 Page 1 of 6 FTSE 10-18 DocuSign Envelope ID: DBA7E3B7-342D-4F54-864A-1 I CA05OF6502 III. Certification Statement I, Paul Weeks, Jr. PE, certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. E 0 Signed by: aul, M WUkS Y. P.f'. 99C79EBBB784409 Signing Official Signature City Engineer Title of Signing Official §dd"2JZ Date Page 2 of 6 FTSE 10-18 CE GROUP June 30, 2022 NCDEQ/DWR Water Quality Section Fast Track Unit 3800 Barrett Drive Raleigh, NC 27609 Re: Elite Mini -Storage (Broadway) Sanitary Sewer Extension NC DePt of Environmental Quality JUL 012022 Rzdcigla Regional Office Please find attached the following information for the requested extension permit: - Application Fee: $480 - Fast Track Sewer System Extension Application (FTA 06-21) — Original and Copy - Flow Tracking/Acceptance Form (Form: FTSE 10-18) - USGS Topographic Map - Vicinity Map - Electronic Thumb Drive (Above Info) This information is provided as required for processing of the requested permit application for the 8" Public Sanitary Sewer Extension for Elite Mini -Storage on Broadway Road in Sanford, Lee County, North Carolina, consisting of a Mini -Storage facility. Immediately downstream of this project is a gravity sanitary sewer system currently owned by and serving the City of Sanford that flows to the Big Buffalo WWTP Facility. The total estimated Daily Design Flow at buildout is listed as 265 GPD (1 gallon / unit). Respectfully Submitted, CE Group, Inc_ Jeff Foster, PE Project Manager 301 Glenwood Avenue I Raleigh, NC 27GO3 1 (919) 3G7-8790 I wv w.cegroupinc.com NC Dept of Environmental Quality JUL 012022 MUSGS %"T US bpo SMFM QUAORWQE SEW Raleigh Regional Office 4t A v INK 7, !rW, J SIT 1V A /W, J a ZftAft co Z TO: NCDEQ — DWQ Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 ATTENTIOW Permitting — Fast Track Sewer CE GROUP 301 GLENWOOD AVENUE, SUITE 220 RALEIGH, NC 27603 Phone: (919) 367.8790 E-Mail: 'eff ce rou inc-com Transmittal DATE, June 30, 2022 PROJECT NO: 265_008 Broadway Self -Storage Quantity Drawing No. Description 1 1 original Fast Track Sewer System Extension Application 1 Project Narrative/Cover Letter 1 Check $480 Application Fee 1 Copy USGS Overall Area Maps 1 Copy Vicinity Location Map NC Dept of Environmental Quality Raleigh Regional Office REMARKS Please let us know if you require any additional information. CC: , CE Group, lnc Signed oster, PE