Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20200779 Ver 2_More Info Received_20220622
Strickland, Bev From: Trone, Rick <rtrone@withersravenel.com> Sent: Wednesday, June 22, 2022 9:24 AM To: Cohn, Colleen M; Lastinger, James C CIV USARMY CESAW (USA) Subject: [External] Bharat Forge Phase 2 revised impact maps, SAW-2019-01659/DWR# 20200779v2 (WR#211466.00) Attachments: 02211466-Wetland Impact Maps-V6.pdf Importance: High CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Good morning, The designer for this project accidentally used the GIS stream line instead of the surveyed stream channel so the alignment of culvert/impact location changed slightly, but the actual impacts did not, except slight change in square footage, so we are submitting the revised impact maps for inclusion with the application/permit. This error came to my attention after we had submitted the application. If you have any questions, please let me know. Thanks, Rick Trone 115 MacKenan Drive I Cary, NC 27511 Office: 919.469.3340 I Direct: 919.538.8184 rtrone@withersravenel.com CONFIDENTIALITY AND NONDISCLOSURE 1 WETLAND A I VICINITY MAP NTS — — — — � \•-. ^� 310 M305 � � \ C � J rr � r/ ✓� �� ,�&� M ,O l _ = - 1 \ ' 300%/ 300 300— 9cr'� �' `� I I I la ) r—' a �.:�••'• e o L -= �_ \ \� � � fWETLANDB -.� "� \\\�\ •�`� sy� ll�1Z � � IIII I -'• ' �-- ��� _ �., �L EXISTING o o' � \ � 1 f �\� Y ���•.. '� ,,,- e � � � � WETLAND C �Z � �°� / 1��ti� .� ti• �g � ) I1 ; . EXISTING •BUILDING - o � }1�� ,!�1 ^�� ..• � / I �� �f I ���Z �1, \ 4 f Q e DING / _ �` cho /,� /f ��� (L �`..� M_ — �\\` `" '� _'✓ -/ `� �, IC,�\ �'—`�\\\\\\ \ \ c?So PROTEc IIiIIII PROPOSED ?''• ��-_�� _ a BUILDING PROPOSED , ����1 �� t �!c, r STREAM 1 1 \ znl` ; `�� BUILDING 2� li ���- PERENNIAL I ( j�, cN n 330 1 % 1 �� �c r �� }��%i//' =` ; II ' (Ili i{lo� I� N \ ti sJ ✓�/ % -� \.� Jfl N�Nt'NIj}i� 4BITHA LANE - D = II ° Nll nuawfln z II M/ J \ 1 (c II WETLAND Grs �0�_�v�j % �� �o` �,\.IIII' I J 1 M �- v-�= �. y` -�—�� -J �C �✓ . " \-��400- `\� �NI -` �:,.✓ ` �l •,SI O o o PROPOSED 1 i o �� r - S , _ ZBS \ L �� croN�p I - 1Z�i } Ilaoll,, IM- N� L 1 1 P PROPOSED �� i1 l PLANT C `�� n� s� r� 1 N �� �\ N II �� �� / 5 ram-- N \ 1 W _ J BUILDING 1� \ _� C \ SCM (POND) L I�liljl 295 3Q\�\\�1M% �v \� 305TFFK \\\\_ EXISTING SCM— - n o o t — a rn (POND) TO BE 3�p 325= ' y. r.30*3( U�g�' 295 � � r90=� 280 / /J{ �> RELOCATED 11 32 III �� 30 n�l� ( �� \°t, 5� `29 M 2 V1 i N,�� 85_280 \ j �3 I% P' �t o r �� N �r J l //\ zs�� I{�} f II ItL.( � ti� ' - 2� 1 tt 5� 1 � I M I � � \ WETLAND D ` �-- -� ,._ �. 25 _ \ =`r ti t PROPOSED 320 \�A� _= = �_ SCM (POND),'K�i rf \\ i \��� ✓ �rf f�t�\( I ��//r/ i� N co PROPOSED f s 310 ` �if�j� / �� IIN RELOCATED EXISTING PUBLIC o I- SANITARY SEWER MAIN { �310 i1 0, SCM (POND) 05 0 305 SHEET B �� — J �� ���_— — V r ?2013153 �4 \\\ f ! 300 \ �J! )/ \� - �I t �= c'oj j�ti 4>� / STREAM 1 N / PERENNIAL s )WETLAND H \ r' \ J I M PACTS: STREAM 4 y r' 1 z .� �� , —N N�. 5 v t / l WETLAND H ( �� ., %, J \ \�� 1 ` INTERMITTENT - / j STREAM 3 N o 1 l�`�'IINTERMITTENT ! 0_ L WEND E J// WETLAND C. jJ 4 SHEET C F i� /� _ WETL L f ,'/,i ss r — _ s%i — 5✓i AND f7E�crL�o9�. IMPACTS: . .\1Z OVERALL STREAM AND WETLAND IMPACT SUMMARY —��-< =-C� t X — X — X �iN 2�0- N j/ 1 \ �',\\ 11) STREAM 2 "j� M INTERMITTENT m PERMANENT PERMANENT /.� \�\��\�����, �1\ i IMPACT SPECIFICATION TEMPORARY PERMANENT (NO FUNCTIONAL LOSS) (FUNCTIONAL LOSS) WETLAND &STREAM F STREAM WETLANDS STREAM STREAM SHEET A I I IMPACT LEGEND (LF) (SF) (AC) (SF) (AC) (LF) (SF) (AC) (LF) (SF) (AC) IMPACTS FOR ACCESS ROAD IMPACTS: I I PERMANENT IMPACTS s1 CULVERT INSTALLATION s 57 0.001 I AUTHORIZED BY USACE NWP 39 I / (SAW-2019-01659) IN 2020 AND ❑ WETLAND S2 ROAD CROSSING - - - - - - - - 53 321 0.007 I NCDWR(PR0 w9O_07791 S3 RIP -RAP DISSIPATOR - - - - - 28 134 0.003 - - - I I I I ❑ STREAM FUNCTIONAL LOSS W1 GRADING - - - 190 0.004 - - - - - - STREAM NO W2 BUILDING & GRADING - - - 5,990 0.138 - - - - - - I I GRAPHIC SCALE ❑ FUNCTIONAL LOSS W3 FIRE LANE & GRADING - - - 3,653 0.084 - - - - - - I I I I I 200 0 100 200 400 TEMPORARY IMPACTS W4 BUILDING & GRADING 9,715 0,223 I I I STREAM 9 57 0.001 19,546 0.449 28 134 0.003 53 321 0.007 1 inch = 200 ft. No. Revision I Date I Bv IjInj. Scale III STREAM &WETLAND M0 Wit ersRavene sneer WR AS NOTED No. Drawn By Date BHARAT FORGE PHASE 2 1/ Engineers I Planners I Surveyors BZ WR 06/09/22 B Y Checked By lob N. IL IMPACTS 115 MacKenan Drive I Cary, NC 27511 WR 02211466.00 t: 919.469.33401 license #: F-1479 I—withersravenel.com PROPOSED f J SCM (POND) — / 270 / � J � 04 \ EXISTING PUBLIC - — `4*11 SANITARY SEWER MAIN . ` J ' clj WETLANDE zz _ I � \ N — \ \ \ IMPACT #S1 — \ TEMPORARY STREAM ~ CULVERT INSTALLATION L - 0.001 AC (9 LF/57 SF) l S J "/� STREAM1�� / 1 PERENNIAL r r o S IMPACT#S2 \x \/ PERMANENT STREAM o C\l (FUNCTIONAL LOSS) x I ROAD CROSSING / I 0.007 AC (53 LF/321 SF) X'\LO i F IMPACT SPECIFICATION OVERALL STREAM AND WETLAND IMPACT SUM TEMPORARY PERMANENT PERMANENT (NO FUNCTIONAL LOS STREAM WETLANDS STREAM (LF) (SF) (AC) (SF) (AC) (LF) (SF) S1 CULVERT INSTALLATION 9 57 0.001 - - - - S2 ROAD CROSSING - - - - - - - S3 RIP -RAP DISSIPATOR - - - - - 28 134 W1 GRADING - - - 190 0.004 - - W2 BUILDING & GRADING - - - 5,990 0.138 - - W3 FIRE LANE & GRADING - - - 3,653 0.084 - - W4 BUILDING & GRADING - - - 9,715 0.223 - - 9 57 0.001 1 19,548 1 0.449 1 28 1 134 _ — — :L;�k WETLAND IMPACT#S3 PERMANENT STREAM (NO FUNCTIONAL LOSS) f RIP RAP DISSIPATOR 0.003 AC (28 LF/134 SF) STREAM 2 ( INTERMITTENT x MARY PERMANENT S) (FUNCTIONAL LOSS) \ \ II \ I STREAM (AC) (LF) (SF) (AC) 53 321 0.007 1 0.003 L \ l 0.003 53 CULVERT UPSTREAM CULVERT DOWNSTREAM 260 260 260 260 255 255 84" RCP 250 250 245 245 0+00 0+50 1+00 r• •rr r• r �. �.'►�! ='. �.� ice. �+:` fir, •������ v TO MATCH PRE —CONSTRUCTION STREAM CONTOUR RIPRAP APRON DETAIL 0+00 0+50 1+r NTS I GRAPHIC SCALE 50 0 25 50 100 1 inch = 50 ft. SCALE: 1 " = 50' HORIZ. 1"=5'VERT. WETLAND & STREAM IMPACT LEGEND PERMANENT IMPACTS WETLAND STREAM FUNCTIONAL LOSS STREAM FUNCTIONAL LOSS TEMPORARY IMPACTS STREAM No. Revision Date I Bv Illn_j_., Scale III WR AS NOTED erS avene sneetuo. Drawn By Date STREAM &WETLAND Engineers I Planners Surveyors WR 06/09/22 BHARAT FORGE PHASE 2 IMPACTS 1/ A Checked By Job No. 115 MacKenan Drive I Cary, NC 27511 WR 02211466.00 t: 919.469.3340 1 license #: F-1479 I www.withersravenel.com G) I o PROPOSED 7 / ) 1 I I _ n\ v l i / i ti \ J Z/ i/ BUILDING l / l / I / )J ! JrJ l l t � IT / 5 Cl) WETLAND G\ i __ f l\ IMPACT#W2 —\���_ J�—'��) 1 N PERMANENT WETLAND BUILDING & GRADING 5,990 SF (0.138 AC) _ \ _ ~ AI- 00 --------------- \ II \\\\ \\ \\\\\ 295 _ r ��\��ti ` moo\ ` `� ✓� i �r / III \\\\\\ \\\\\\\\\�o� 300 �\ ��\�� ^\ \ ���� — ��— \`L — ~l �\ �co Lis-= 300— \ \ 310 305 ._.-- �,-- IMPACT#W1 \ 1 305 300 GRADING WETLAND D — _ _ �- �— OVERALL STREAM AND WETLAND IMPACT SUMMARY 1 \ \ '70 1 I I I ) 190 SF (0.004 AC) 295 _ P A _ \ _ 'l ` 1 -A y r ( ) m — _ \ PERMANENT PERMANENT \ \ ) \tro ` ( 290 TEMPORARY PERMANENT � (NO FUNCTIONAL LOSS) (FUNCTIONAL LOSS)— U IMPACT SPECIFICATION \ ` 1 I ) \ 1 \I ` 1 \ 285 a STREAM WETLANDS STREAM STREAM 280�- PROPOSED / \ (LF) (SF) (AC) (SF) (AC) (LF) (SF) (AC) (LF) (SF) (AC) \ 1 \ ` \ , RELOCATED \ 1 \ I (� ) �� SCM (POND) jI S1 CULVERT INSTALLATION 9 57 0.001 - - - - - - - - \ ; { I ` \ � � � — S2 ROAD CROSSING - - - - - - - - 53 321 0.007 WETLAND & STREAM S3 RIP -RAP DISSIPATOR - - - - - 28 134 0.003 - - - ) I M \ ) / I \ 1 J ( I r ` \) ) � \ \ IMPACT LEGEND W1 GRADING - - - 190 0.004 I \ I J I \ PERMANENT IMPACTS W2 BUILDING & GRADING - - - 5,990 0.138 - - - - - - / I \ \ l \ \ \ ` GRAPHIC SCALE 1 I I ) I J \ WETLAND 50 0 25 50 100 [ — W3 FIRE LANE &GRADING - - - 3,653 0.084 - - - - - - �� I / r e) I / \ I ❑ ` W4 BUILDING & GRADING - - - 9,715 0.223 STREAM 9 57 0.001 19,546 0.449 28 134 0.003 53 321 0.007 1 / �/J ` El FUNCTIONAL LOSS 1 inch = 50 ft. / / I No. Revision Date Bv Designer Scale STREAM & WETLAND �� Wit ersRavene WR AS NOTED Sheet No. Drawn By Date BHA RAT FORGE PHASE 2 1 0 11 I Planners Surveyors11 B WR 06/09/22EngineersY Checked By lob No. IMPACTS 115 Mken. n Drive Cary, NC 27511rs WR 02211466.00 t: 919.469.3340 license #: F-1479 www.withersravenel.com \ /_ -- —` __ 330� — \ ----- ____ _—_------------------ i--- _----- — EXISTING SCM PROPOSED / / ( I I I / (POND) TO BE PLANT / 1 I I RELOCATED BUILDING Cl) 1 \ 1` ���� ���� \_, 1\�� ��J`�� M 3�0- IMPACT #W4 r \ PERMANENT WETLAND BUILDING &GRADING 9,715 SF (0.223AC) 320 315 IMPACT#W3 / 315 \ i / r / / / / / / PERMANENT WETLAND \ FIRE LANE & GRADING r /J 3,653 SF (0.084 AC) \00, � 310 305 LOP, \ \ \ \ \ I 305 295 OVERALL STREAM AND WETLAND IMPACT SUMMARY °1 PERMANENT PERMANENT TEMPORARY PERMANENT (NO FUNCTIONAL LOSS) (FUNCTIONAL LOSS) IMPACT SPECIFICATION 290� �� \ a WETLAND � STREAM WETLANDS STREAM STREAM I � / / ( � ( / � \ � \ \ \ ` �\ � - � � / � /r /� / / � I 1 ( ) � ) 1 r (/1 I \ � \ ✓` \i �` 1 \ (LF) (SF) (AC) (SF) (AC) (LF) (SF) (AC) (LF) (SF) (AC) 1 / x\\ S1 CULVERT INSTALLATION 9 57 0.001 S2 ROAD CROSSING - - - - - - - - 53 321 0.007 \ / / \ \ �— WETLAND & STREAM S3 RIP -RAP DISSIPATOR - - - - - 28 134 0.003 - - . / / / / 1 , — " �� _ IMPACT LEGEND — W1 GRADING - - - 190 0.004 - - - - - - I 1 / ~ \ _\ 1 �� \\ \ PERMANENT IMPACTS v \ W2 BUILDING & GRADING - - - 5,990 0.138 - - - - - - \ \\� \ \ \ \\ \ / GRAPHIC SCALE \ \ W3 FIRE LANE & GRADING - - - 3,653 0.084 - - - - - - \ \ \ \ \ \ \� \ f / ❑ WETLAND 50 0 25 50 100� \ \ \ W4 BUILDING & GRADING - - - 9,715 0.223 STREAM \ \ �� \ '� El FUNCTIONAL LOSS 1 inch — 50 ft. 9 57 0.001 19,546 0.449 28 134 0.003 53 321 0.007 ) \ \ \ \ \ \ \ �� No. Revision Date By Designer Scale STREAM &WETLAND NO Wit ersRavene WR AS NO Sheet No. Drawn By Date BHA RAT FORGE PHASE 2 1/ Engineers I Planners I Surveyors C WR 06/09/22 B Y ��A Checked By ]ob No. IMPACTS 115 MacKenan Drive Cary, NC 27511 WR 02211466.00 t: 919.469.3340 1 license #: F-1479 I www.withersravenel.cum