20200474 Ver 2_More Info Received_20220526
Strickland, Bev From: Ashley Steele Bentz <abentz@smeinc.com> Sent: Thursday, May 26, 2022 10:40 AM To: Phillips, George L CIV USARMY CESAW (USA); Cohn, Colleen M Subject: [External] St. Albans PCN revisions Attachments: Extended Responses.pdf; 0002-742-CSP-Sanitary Plan.pdf CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. DWR#20200474 V2 and USACE SAW-2020-00607 Colleen's Comments: 1) Please provide the Division with a copy of your response to the April 8, 2022, Request for Additional Information from the US Army Corps of Engineers. 2) This project received a NOV in October 2021 for the flexamat matting and concrete. The flexamat was removed in response to the NOV, but it is still shown on the plans included with the submittal. Please remove the flexamat from the plans. See attached for an updated copy. 3) The plans show the pipe as a 20 inch steel casing pipe, but only 1 linear foot (12 inches) of permanent impacts are requested. Please provide additional information on this impact. You are correct— I misread the plans. There will be 20 inches of impact, rounded up to two feet. 4) Additionally, plans still say "gradually slope creek bed over the top of the steel casing pipe" but my understanding is that the pipe was installed over the streambed. Is there room for the passage of aquatic life? What is the side -view of the pipe as -built? Please provide additional information on this impact. The plans had not been updated correctly. See attached for an updated copy. Lyle's Comments: 1. It appears that there was an issue with the submittal of the PCN. I have attached the file received. Some of the written sections of the PCN were shortened and I am unable to read the full response. C. 5a. Comments, D. 3j. comments, E. la, E. lb, G. 2b, G. 3b, G. 5j, Name, Signature and Date are some examples of the submittal issue. Please address these comments. See attached — written sections have been typed out and attached. 2. In order to verify compliance with NWP 18, please provide the cubic yards of the discharged fill material below the ordinary high water mark. Ten cubic yards. 3. The attached "50 Sanitary Plan and Profile" exhibit included with the application notes that "flexamat" or an approved equal be used on each site of the pipe. If this is the case please provide justification for this fill and updated the PCN and exhibits accordingly. Plans have been updated to exclude the flexmat. Please let me know if I missed anything or if you need anything else to process the permit! Thanks, Ashley Ashley Bentz, PWS Project Scientist 1 III BUILT FOR VERSATILITY S&ME 3201 Spring Forest Road Raleigh, NC 27616 map 0: 919.954.6285 M: 919.896.0758 www.smeinc.com Linkedln I Twitter I Facebook This electronic message is subject to the terms of use set forth at www.smeinc.com/email. If you received this message in error please advise the sender by reply and delete this electronic message and any attachments. Please consider the environment before printing this email. 2 D. Proposed Impacts Inventory 3. Stream Impacts 3j: The sanitary sewer alignment was installed in 2021. The sanitary sewer is exposed due to the elevation of the project site and the existing sanitary sewer that it connects to. As a result, the project resulted in one foot of linear stream impacts consisting of the sanitary sewer line. G. Supplementary Information 2. Violations 2b: The original permits granted by the USACE and the NCDWR (attached) did not account for permanent impacts resulting to Big Branch from the sewer line crossing. At the time of the original permit submission, engineers anticipated that the sanitary sewer could be installed beneath the stream bed. However, due to the elevation of the site and the elevation of the existing sewer line the project's sanitary sewer line was tying into, the sanitary sewer needed to be installed above grade to meet the required gradients for the sewer line. This permit is intended to address the additional impacts not included by the original permit by the sanitary sewer. 3. Cumulative Impacts 3b: The sewer line has been installed to accommodate a previously permitted development. The sewer line will not be used to support additional development. 5. Endangered Species and Designated Critical Habitat 5j: The NC Natural Heritage Program online data explorer (https:www.ncnhp.org), US Fish and Wildlife Information for Planning and Consultation (IPaC) report. No critical habitat or element occurrences of protected species were identified within one mile of the project site. LEGEND PRIMARY TREE CONSERVATION AREA \\\ \\ \\ SECONDARY TREE CONSERVATION AREA GREENWAY TREE CONSERVATION AREA FLOODWAY 100-YR FLOODPLAIN MH 12" STM CB Ak PROPOSED STORM SEWER CGI SAN SERV. 8" SAN PROPOSED SANITARY SEWER MH s" WM a PROPOSED WATER MAIN CASING FH MH EX. 12" STM CB -I -ST ST- - EXISTING STORM SEWER CGI EX. SAN SERV. EX. 8" SAN EXISTING SANITARY SEWER -SA-SA-- MH EX. 8" WM WV WA wA~,a--- EXISTING WATER MAIN R EX. CASING FH PHASE LINE ri I ¢ 0 0 o J LL_ 50' NEUSE RIVER RIPARIAN BUFFER TOP BANK U7 1+ EX. 30' CITY OF RALEIGH 12" SA, SANITARY EASEMENT (OFFSITIE) < - - D.B. 17789, PG. 46 l Ad6\1 VARIABLE WIDTH CITY OF RALEIGH GREEN WAY EASEMENT 50' OFFSET FROM TOB I I I I I I I PROP. 30' CITY OF RALEIGH SANITARY EASEMENT 2+00 3+00 -- 2 ---- 8„ SA- �4 / O CO / / 6 ,. q S �Q / / do s •• S �, / 17 / qS S'IS s SAS 4 s / l° , ls•� ST / s s / Q / 18" ST 3 t 4+00 s� 1 �- ---- CT 15ST " - -- ---- m 285 1 2 3 4 5 0 0 280 ------------------------------------------------------------------------------------------------------------------------ ------ - ---------------:-------------- --Ln- N N 11 N N 27, 5 r ------------------------ -------------------------,----------------------------------------- ,----------------------,----------------------- ,----------------------------------------------------------------------------------------------------------------------------------- 210 I I I I ______ __________/____ _______ _ _______rT________ rr24" S7Mj 265 IN 267.42 200 PROPOSED GRADE _ y 15" STMJ Lrn ---INV,=258.21265 L0 ------------------------------------------------------------------------------------------------------------------------------------------------------------------ -------- -------------------------- ------ ---------------------- - ------ ------- ---------- EXISTING GROUND ® SAN PIPS% : 250 - �- 25 2 75" STM I � I I I 245 -- ------ ------ ---- IN - - r--------- ---------r---------------- ------ --------,---------------------- --- ---------------------------------------------- -------------------------------------------- --------------------------------------- V.�247.18 12', WM M INV.=2:42.4� : 240 ------ -----; - - r------- -- ---------r------------------------r-------,----------------r-------,---------------- -------------------- ------�s r-S------ ------ - --------------------------------------------- --------------------- ------ ------- ---------------- ------- --------I W -- ------ TM I OOfi T � INV.=�40.01 O a; W 235 �I 55' ~ N N - - -- ----- - ------ ----- ------ ------ ----- ------ 100-YR- ELEV:232.8 co r M N W Ln W 230 1--,'N N ---------Ir------- - - -- -------------------------- ----------------------------------- --- -------------- ---- -----------'----------------------------------------------------------------------------- VENT / VENT 225 ----- --- - 00% - r------- - -\1- ------ --------------------------r----- ,------------ ------------------------------- - -g-----------------,----------------r-------,----------------------- ----------------r-------,----------------r-------;--------r-------r-------,----------------r-------,--------i--- U ¢ z $' \P m ¢ CASING PIPE: PARTIA�LY r 220 0° EMBEDDED_ Ifs_ CREEK'_BED _FL OW - - ------ a --- 1 1- - 8a 12--------1 ------ ------ ---- ----------------------------------------------------------------------------------------------------- � � o S OVER PIPE I �/ �______�________�________�_______�________�________ ___ � � GOE 215 -� IN:2`I(NE) ----- OUT:21'0.88 210 INVERTS WERE 170.00 _ �_ 12 I_P _®_0. 0%----' --- �-------------- INTERPOLATED FRdM N �n FIELD VERIFIED OPEN CUT WITH' 100 LF: OF 2©5 UPSTREAM AND N 20" STEEL CASING PIPEN _ OWN- STREAM--- ----- = _ ----- -------- -------I --- ------ ------ -------------- MANHOLES. w 1� .. 0 I �.. v I� U I �. :a I 2Q0 U' - -- a -'---- '-------------------'--------------- ----- ------ ----- ------------------- w -- Q----------' w -- a--'--------'-------'--------'--------'-------'--------'--------'-------'--------------------------------:w w ¢ o w w o - - --- - - _----------------- o of , il� _ UJ z Iw _ CD ¢ o ¢ 0 0 0 0 0 : o 0 105 0 Y N � � N !� r_______ - - - - r_______,_ �______ _r_ _ _ ______________ ________________________ _______ ________________ _______ ________________ _______ __________ - - O - - - r_ - - p - - ,_ r_ - ,_ r_ - _______ _____ ________________ _______jam p p 0 o Ic � 0 r L to ;00 + + + + I+ STAEI 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 PROP. GRADE 247.2 24 . 4 2 2.57 2 5.7 5 . 9 26 .19 265.3 6 0 2 1.80 2 T3.3 EX. GROUND 215.83 216.15 217.35 221.27 226.49 231.68 237.46 243.98 248.02 249.38 249.32 250.16 250.88 252.83 261.27 269.31 275.59 278.59 INVERT 211.55 211.70 211.85 214.51 218.51 222.51 226.51 230.51 234.51 237.91 240.96 243.85 246.60 249.35 252.10 254.85 257.60 259.74 CUT 4.28 4.45 5.50 6.76 7.98 9.17 10.95 13.47 13.51 11.46 8.36 6.30 4.27 3.47 9.17 14.46 17.99 18.85 ATTENTION CONTRACTORS The Construction Contractor responsible for the extension of water, sewer, and/or reuse, as approved in these plans, is responsible for contacting the Public Works Department at (919) 996-2409, and the Public Utilities Department at (919) 996-45,10 at least twenty four hours prior to beginning any of their construction. Failure to notify both City Departments in advance of beginning construction, will result in the issuance of monetary fines, and require reinstallation of any water or sewer facilities not inspected as a result of this notification failure. Failure to call for Inspection, Install a Downstream Plug, have Permitted Plans on the Jobsite, or any other Violation of City of Raleigh Standards will result in a Fine and Possible Exclusion from future work in the City of Raleigh. NARRATIVE OF REVISIONS 1. SSMH TOP ELEVATIONS FOR STRUCTURE #3, #4 AND #5 REVISED. 2. PROPOSED GRADE PROFILE UPDATED BASED ON STREET PROFILE REVISION. 3. SSMH 1-2 STANDARD DRAWING REVISED TO MATCH COR DETAIL FOR WATERTIGHT MANHOLE. 4. VENTS ADDED TO MANHOLES IN FLOODPLAIN. 5. 100-YEAR WATER ELEVATION SHOWN. 6. LOT CONFIGURATION REVISED BASED ON S-16-17. CHANGES TO LOTS 15-17. 7. PROVIDED STEEL CASING IN -LIEU OF CONCRETE ENCASEMENT. CARRIER PIPE - 3/8" STEEL PLATE, TYP 3/8%4" STEEL PLATE, TYP 5/8" 0 A325 BOLT CASING PIPE 3/16 V 4 1" R ON ALL CORNERS STEEL CASING NOTES: 1. STEEL PIPE SHALL BE EITHER SPIRAL WELDED OR SMOOTH WALL SEAMLESS WITH A MINIMUM YIELD STRENGTH OF 35,000 PSI 2. STEEL CASING PIPE SHALL HAVE A MINIMUM WALL THICKNESS OF 0.375 INCHES. 3. DUCTILE IRON CARRIER PIPE SHALL BE SUPPORTED WITH TWO SPIDERS AT EVERY JOINT WITHIN THE CASING PIPE USING APPROVED PIPE ALIGNMENT GUIDE. ALL JOINTS SHALL BE RESTRAINED JOINT. NOTES: 1. INVERT ELEVATIONS IN ALL EXISTING STRUCTURES HAVE BEEN FIELD VERIFIED. 2. ALL BACKFILL SHALL BE PLACED PRIOR TO SANITARY SEWER INSTALLATION. 0 25 50 100 NOTE: USE A MINIMUM OF 2 SPIDERS PER JOINT PLACED ONE FOURTH OF THE PIPE JOINT LENGTH IN FROM BOTH THE BELL AND SPIGOT. PIPE ALIGNMENT GUIDE NON -SHRINK GROUT 234.8' BULKHEAD AT EACH TURN DOWN ELBOW END OF CASING PIPE WITH INSECT SCREEN STYROFOAM PLUG TO ASSIST GROUT PLACEMENT, 8 ° ALL AROUND STEEL CASING PIPE DIP CARRIER PIPE 2" 0 GALV STEEL VENT, TWO PER CASING, ONE AT EACH END OF CASING PIPE PROVIDE PLASTIC SHEET BOND -BREAKER BETWEEN �N\' CARRIER PIPE AND GROUT, ALL AROUND PROVIDE 2" 0 GALV STEEL DRAIN / �� NON -SHRINK GROUT SHALL BE IN BULKHEAD AT LOW END j�� �� j "EUCO-N-S" BY THE EUCLID OF CASING PIPE AND 1/3 CHEMICAL COMPANY; "MASTERFLOW CU YD OF CRUSHED STONE /j��j��j�/j��j� 713" BY MASTER BUILDERS, AT DRAIN, WRAP STONE OR EQUAL. WITH FILTER FABRIC TYPICAL CASING PIPE PLUG PUBLIC SEWER COLLECTION / EXTENSION SYSTEM THE CITY OF RALEIGH CONSENTS TO THE CONNECTION AND EXTENSION OF THE CITY'S PUBLIC SEWER SYSTEM AS SHOWN ON THIS PLAN. THE MATERIAL AND CONSTRUCTION METHODS USED FOR THIS PROJECT SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS OF THE CITY'S PUBLIC UTILITIES HANDBOOK. CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT PERMIT # S-4622 REV AUTHORIZATION TO CONSTRUCT See digital signature 20 SITE PERMIT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION PLANS FOR THE PROPOSED USE HAVE BEEN REVIEWED FOR GENERAL COMPLIANCE WITH APPLICABLE CODES. THIS LIMITED REVIEW, AND AUTHORIZATION FOR CONSTRUCTION IS NOT TO BE CONSIDERED TO REPRESENT TOTAL COMPLIANCE WITH ALL LEGAL REQUIREMENTS FOR DEVELOPMENT AND CONSTRUCTION. THE PROPERTY OWNER, DESIGN CONSULTANTS, AND 10 CONTRACTORS ARE EACH RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE CITY, STATE AND FEDERAL LAWS. THIS SPECIFIC AUTHORIZATION BELOW IS NOT A PERMIT, NOR SHALL IT BE CONSTRUED TO PERMIT ANY VIOLATION OF CITY, STATE OR FEDERAL LAW. ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL RULES AND REGULATIONS. THIS APPROVAL OF THIS ELECTRONIC DOCUMENT IS ONLY VALID IF THE DOCUMENT HAS NOT BEEN MODIFIED AND THE DIGITAL SIGNATURE BELOW IS VALID: 0 CITY OF RALEIGH DEVELOPMENT APPROVAL 0 O I� o N (O T cn .S a E o �ro o a m0 z 12 0 L r N U QI U a- Of z a_ Q z� Q Ii w a_ V W Q I --I > 0 a_ w rr a_ Z Q J a_ sruilo m) 03/03/2021 U) Z a Z m a W JQ a J Z O Q Cl)0 U H U cl)� a ? a O z 0 Z Ill a Z - Z a M W z D 0 Z /� cl) 0. a H Q 3: J U J Z = W w WLU I.L a ILL. o U W U v♦ Z Z 0 p `a U Ill X 2 J Q H- Q m r J D Q m z 0 0 Fn D FA5;w ()� w rY } N .4 O o N 04 rn 0 o oN 0 N 0 � � C,4a M 0 V) 0 Date: 03/03/2021 Scale: H: 1" = 50$ V: 1" = 10' Drawn By: Checked By: JLB JDW Project Number: 16-0002-742 Drawing Number: 50/59