HomeMy WebLinkAboutWQCSD0108_Compliance Evaluation Inspection_20220819ROY COOPER Governor ELIZABETH S. RISER Secretary RICHARD E. ROGERS, JR. Director NORTH CAROLINA Environmental Quality August 15, 2022 Michael S Bales Badin Shores Resort Owners' Association Inc #1 Club House Dr New London, NC 28127 SUBJECT: Compliance Inspection Report Badin Shores Resort Collection System Collection System Permit No. WQCSD0108 Montgomery County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Badin Shores Resort Collection System on 7/20/2022. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Collection System Permit No. WQCSD0108. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. The Badin Shores Collection System is overseen by Handy Sanitary. There are four pump stations within this system, #4 and #5 were inspected. The pump stations are inspected weekly and all use SCADA, which was functional when tested during the inspection. The pump stations use probes as opposed to traditional floats to monitor the wet wells. North Carolina Deportment of Environmental Quality I Division of Water Resources Fayetteville Regional ice 1225 Green Street Sure 714 I Fayetteville. North Carolina 25201 910.4333300 If you should have any questions, please do not hesitate to contact Danielle Simpson with the Water Quality Regional Operations Section in the Fayetteville Regional Office at 910-433-3300 or via email at danielle.simpson@ncdenr.gov. Sincerely, DocuSignedd by: Q •V v"e^v '-5189C2D3DD5C42B... J. Trent Allen, Regional Supervisor Water Quality Regional Operations Section Fayetteville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Fayetteville Regional Office (DS) PERCS Compliance/Enforcement Unit 11E9 North Carolina Department of Environmental Quality I Division of Water Resources Fayetteville Regional ice 1225 Green Street Sure 714 I Fayetteville. Worth Carolina 25201 910.4333300 Compliance Inspection Report Permit: WQCSD0108 Effective: 03/01/00 SOC: Effective: County: Montgomery Region: Fayetteville Contact Person: Michael S Bales Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 07/20/2022 Primary Inspector: Danielle Simpson Secondary Inspector(s): Reason for Inspection: Routine Expiration: Expiration: Title: President Certification: Entry Time 09:30AM ,-DocuSigned by: U•pt.vue.11t, cJ p ovl, 8C7638281 DAB46D_. DocuSigned by: 5189C2D3DD5C42B... Owner : Badin Shores Resort Owners' Association Inc Facility: Badin Shores Resort Collection System Phone: 336-461-3833 Phone: Exit Time: 11:OOAM 8/16/2022 Phone: 910-433-3334 8/18/2022 Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Deemed permitted collection system management and operation Facility Status: Compliant Not Compliant Question Areas: ▪ Miscellaneous Questions II Spills/Response Plan ▪ Manholes (See attachment summary) ▪ General ▪ Inspections ▪ Pump Stations ▪ Grease Control ▪ Lines Page 1 of 6 Permit: WQCSDO1 08 Owner - Facility: Badin Shores Resort Owners' Association Inc Inspection Date: 07/20/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: The Badin Shores Collection System is overseen by Handy Sanitary. All documents were organized and readily available at the time of inspection. Grease education is distributed on letters and flyers that are mailed. Logbooks track maintenance and system inspections. There are four pump stations within this system, #4 and #5 were inspected. The pump stations are inspected weekly and all use SCADA, which was functional when tested during the inspection. The pump stations use probes as opposed to traditional floats to monitor the wet wells. Page 2 of 6 Permit: WQCSDO1 08 Owner - Facility: Badin Shores Resort Owners' Association Inc Inspection Date: 07/20/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine General # Is this system a satellite system? # If Yes, what is system name or permit number? Is there a overall sewer system map? Does the map include: Pipe sizes Pipe materials (PVC, DIP, etc) Pipe location # Flow direction # Approximate pipe age # Pump station ID, location and capacity # Force main air release valve location & type # Location of satellite connections Are system maintenance records maintained? Comment: As-builts, Grease Control Is grease/sewer education program documented with req'd customer distribution? # Are other types of education tools used like websites, booths, special meetings, etc? If Yes, what are they? (This can reduce mailing to annual.) For public systems, is there a Grease Control Program via an ordinance/agreement? If Yes, does it require grease control devices at applicable locations? Is the Grease Control Program enforced via periodic inspections/records review? Is action taken against violators? Comment: Flyer and letters in the mail. Spills and Response Action Plan # Is system free of known points of bypass? If No, describe type of bypass and location # Have there been any sewer spills in the past 3 years? If Yes, were they reported to the Division if meeting the reportable criteria? If applicable, is there documentation of press releases and public notices issued? Are all spills or sewer related issues/complaints documented? # Are there repeated overflows/problems (2 or more in 12 months) at same location? # If Yes, is there a corrective action plan? Is a Spill Response Action Plan available? Is a Spill Response Action Plan available for all personnel? Yes No NA NE • ❑ ❑ ❑ Handy Sanitary • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ ❑ • ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 3 of 6 Permit: WQCSDO1 08 Owner - Facility: Badin Shores Resort Owners' Association Inc Inspection Date: 07/20/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Does the plan include: # 24-hour contact numbers # Response time # Equipment list and spare parts inventory # Access to cleaning equipment # Access to construction crews, contractors, and/or engineers # Source of emergency funds # Site sanitation and cleanup materials # Post-overflow/spill assessment Comment: No spills in the past three years. Inspections Are adequate maintenance records maintained? Are pump stations being inspected at the required frequency? Is at least one complete functionality test conducted weekly per pump station? Is there a system or plan in place to observe the entire system annually? Is the annual inspection documented? # Does the system have any high -priority lines/locations? Are inspections of HPL documented at least every 6 months? Are new lines being added to the HPL list when found or created? Comment: 1 HPL, Logbooks track work. Lines/Right-of-Ways/Aerial Lines Please list the Lines/Right of Ways/Aerial Lines Inspected: Are right-of-ways and easements maintained for the full width for access? If No, give details on temporary access: Is maintenance documented? Were all areas/lines inspected free of issues? Comment: Manholes Please list the Manholes Inspected: Are manholes accessible? # Are manhole covers/vents above grade? Are manholes free of visible signs of overflow? Are manholes free of sinkholes and depressions? Are manhole covers present? # Are manholes properly seated? • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Page 4 of 6 Permit: WQCSDO1 08 Owner - Facility: Badin Shores Resort Owners' Association Inc Inspection Date: 07/20/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine # Are manholes in good condition? # Are inverts in good condition? Is flow unrestricted in manholes? Are manholes free of excessive amounts of grease? Are manholes free of excessive roots? Are manholes free of excessive sand? Are manhole vents screened? Are vents free of submergence? Are manholes free of bypass structures or pipes? Comment: Pump Stations Please list the Pump Stations Inspected: #4 and #5 # Number of duplex or larger pump stations in system # Number of vacuum stations in system # Number of simplex pump stations in system # Number of simplex pump stations in system serving more than one building How many pump/vacuum stations have: # A two-way "auto polling" communication system (SCADA) installed? # A simple one-way telemetry/communication system (auto -dialer) installed? For pump stations inspected: Are they secure with restricted access? Were they free of by-pass structures/pipes? Were wet wells free of excessive grease/debris? # Do they all have telemetry installed? Is the telemetry system functional? Is a 24-hour notification sign posted ? Does the sign include: Owner Name? Pump station identifier? # Address? Instructions for notification? 24-hour emergency contact numbers? Are audio and visual alarms present? Are audio and visual alarms operable? # Is there a backup generator or bypass pump connected? • ❑ ❑ ❑ • ❑ ❑ ❑ ▪ ❑ ❑ ❑ ❑ ❑ ❑ • • ❑ ❑ ❑ ▪ ❑ ❑ ❑ Yes No NA NE 4 0 0 0 4 0 • ❑ ❑ ❑ • ❑ ❑ ❑ ▪ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ▪ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ Page 5 of 6 Permit: WQCSDO1 08 Owner - Facility: Badin Shores Resort Owners' Association Inc Inspection Date: 07/20/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine If tested during inspection, did it function properly? Is the back-up system tested at least bi-annually under normal operating conditions? # Does it have a dedicated connection for a portable generator? # Is the owner relying on portable units in the event of a power outage? # If Yes, is there a distribution plan? If Yes, what resources (Units/Staff/Vehicles/etc) are included in Plan? Backup pump on -site at one station for use if needed. # Does Permittee have the approved percentage of replacement simplex pumps? Is recordkeeping of pump station inspection and maintenance program adequate? Do pump station logs include at a minimum: Inside and outside cleaning and debris removal? Inspecting and exercising all valves? Inspecting and lubricating pumps and other equipment? Inspecting alarms, telemetry and auxiliary equipment? Comment: Detailed log books. The pump stations use probes as opposed to traditional floats. ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 6 of 6