Loading...
HomeMy WebLinkAboutNCC222898_Site Plan or Location Map_20220818MORTON ST GREENLAND A VE 0 o' ARTY AVE SITE OL WILKINSON BLVD VICINITY MAP NOT TO SCALE 8+42 8+00 CHRIST PRESBYTERIAN CHURCH D.B. 1126, PG. 25 LOTS 2, 3 & 14-16, BLOCK 5, CHARLOTTE INVESTMENT COMPANY PROPERTY M.B. 332, PG. 208 PIN: 067-058-11 ZONING: R-22 MF 7+100 OE - TRASH COMPACTOR AND RECYCLE CENTER CITY OF CHARLOTTE REQUIREMENTS 20. CERTIFICATION AND STREET CUT PERMITS ARE REQUIRED FOR UTILITY CUTS ON CITY SITE NOTES STREETS. ALLOW 7 DAYS PROCESSING FOR PERMIT. FOR INFORMATION CONTACT 1. COORDINATE ALL CURB AND STREET GRADES IN INTERSECTIONS WITH INSPECTOR. CHARLOTTE DEPARTMENT OF TRANSPORTATION (704-336-4025) OR VISIT 1. PLANIMETRIC AND TOPOGRAPHIC INFORMATION SHOWN ARE BASED ON A SURVEY PREPARED BY http: //www.charmeck.org/Departments/Transportation/Street+Maintenance/hame.htm R.B. PHAR & ASSOCIATES. P.A. DATED JAN. 29, 2021 2. ALL ROAD IMPROVEMENTS AT ARTY AVE., BERRYHILL RD. & WIKINSON BLVD. ARE TO BE COORDINATED WITH THE CITY OF CHARLOTTE ENGINEERING DEPARTMENT PRIOR TO 21. NON-STANDARD ITEMS (IE: PAVERS, IRRIGATION SYSTEMS, ETC.) IN THE 2. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING BENCHMARKS AND OTHER REFERENCE POINTS CONSTRUCTION. RIGHT-OF-WAY REQUIRE A RIGHT-OF-WAY ENCROACHMENT AGREEMENT WITH THE THROUGHOUT THE CONSTRUCTION PERIOD. 41 CHARLOTTE DEPARTMENT OF TRANSPORTATION/NORTH CAROLINA DEPARTMENT OF 3. TRANSPORTATION BEFORE INSTALLATION. FOR CITY OF CHARLOTTE MAINTAINED 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT OF ALL CONSTRUCTION ELEMENTS. P� STREETS, CONTACT KRYSTAL BRIGHT AT (704) 336-3888 OR ALL DISCREPANCIES IN DIMENSIONING SHALL BE REPORTED TO THE ENGINEER AND OWNER 4. SIGHT TRIANGLES SHOWN ARE THE MINIMUM REQUIRED. Krystal.Bright@chorlottenc.gov. IMMEDIATELY. 5. IN ROLLING AND HILLY TERRAINS, SWEEPING OF THE STONE BASE AND/OR 22. SIDEWALK WITHIN THE CITY'S R/W THAT REQUIRES REPLACEMENT AS PART OF THE 4. DIMENSIONS ARE FACE OF CURB AND FACE OF BUILDING UNLESS OTHERWISE SHOWN. APPLICATION OF A TACK COAT MAY BE REQUIRED NEAR INTERSECTIONS. THESE DEVELOPMENT AND/OR STREET IMPROVEMENTS SHOULD BE PHASED IN SUCH A WAY REFER TO ARCHITECTURAL TURAL PLANS FOR BUILDING DIMENSIONS. REQUIREMENTS WILL BE ESTABLISHED BY THE INSPECTOR AND BASED ON FIELD AS TO MINIMIZE THE DURATION OF THE SIDEWALK CLOSURE TO THE EXTENT FEASIBLE. CONDITIONS. THE DEVELOPER SHOULD MAKE EVERY ATTEMPT TO HAVE SIDEWALK REPAIRED AND 5. WHEN DETAILS ARE PROVIDED, CONTRACTOR SHALL CONSTRUCT JOB PER SPECIFIC DETAILS, REOPENED FOR PUBLIC USE WITHIN 30 DAYS OF REMOVAL. AND NOT BY SCALING FROM THESE PLANS. 6. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF -SITE GRADING, PERMISSION 23. ANY WORK WITHIN THE CITY'S R/W THAT REQUIRES CLOSURE OF A SIDEWALK OR 6. ALL IMPROVEMENTS AND WORK SHALL BE IN ACCORDANCE WITH THESE PLANS AND MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS. TRAVEL LANE MUST BE APPROVED BY CDOT AND WILL REQUIRE A R/W USE PERMIT SPECIFICATIONS AND ALL APPLICABLE STATE AND LOCAL STANDARDS. IN THE ABSENCE OF OR R/W LEASE DEPENDING UPON THE PROPOSED DURATION OF CLOSURE. THESE SPECIFIC PRODUCT SPECIFICATIONS OR CONSTRUCTION PROCEDURE, CONTRACTOR SHALL REFER 7. IN ORDER TO ENSURE PROPER DRAINAGE, KEEP A MINIMUM OF 0.5% SLOPE ON THE APPROVALS ARE IN ADDITION TO SITE APPROVALS AND SHOULD BE COORDINATED TO THE 2018 NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES, AND SHALL CURB FOR PUBLIC AND PRIVATE STREETS. WITH CDOT PRIOR TO CONSTRUCTION. CONTRACTOR SHALL CONTACT ERIC SUBMIT THE DETAIL/SPECIFICATIONS TO THE ENGINEER FOR APPROVAL. WEIDEMANN AT (980) 722-5463 OR Eric.Weidemann@charlottenc.gov AT LEAST 5 8. SUBSURFACE DRAINAGE FACILITIES MAY BE REQUIRED IN THE STREET RIGHT-OF-WAY BUSINESS DAYS PRIOR TO BEGINNING WORK FOR IMPACTS LESS THAN 30 DAYS. 7, IF A CONFLICT EXISTS BETWEEN SPECIFICATIONS ON THESE PLANS, SPECIFICATIONS IF DEEMED NECESSARY BY THE INSPECTOR. CONTRACTOR SHALL CONTACT CASEY MASHBURN AT (704) 336-8348 OR REFERENCED ON THESE PLANS, DETAILS ON THESE PLANS, AND MANUFACTURERS Cosey.Mashburn@charlottenc.gov AS SOON AS POSSIBLE FOR IMPACTS GREATER THAN RECOMMENDATIONS, THE CONTRACTOR WILL BE HELD TO THE STRICTER SPECIFICATION. 9. CURB AND GUTTER SHOWN ON PLANS ALONG ARTY AVE. MAY BE ADJUSTED BASED 30 DAYS. EVERY EFFORT SHALL BE MADE TO CONSTRUCT IMPROVEMENTS WITH UPON FIELD STAKING BY CITY ENGINEERING. ASSOCIATED STORM DRAINAGE MAY MINIMAL IMPACT TO DRIVERS AND PEDESTRIANS. 8. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING THE SITE IN A MANNER SUCH THAT WORKERS, - ALSO REQUIRE MODIFICATION BASED UPON FIELD CONDITIONS. OWNER REPRESENTATIVES, AND THE GENERAL PUBLIC IS PROTECTED FROM HARM. 24. RIGHT-OF-WAY CLOSURES LONGER THAN 30 DAYS REQUIRE A R/W LEASE MAY INSTALL TEMPORARY PERIMETER FENCING AS APPROVED BY OWNER. 10. THE PURPOSE OF THE STORM DRAINAGE EASEMENT (SIDE)CONTRACTOR IS TO PROVIDE STORM AGREEMENT WHICH WILL INCLUDE THE SUBMITTAL OF A TRAFFIC CONTROL PLAN. CONTRACTOR IS RESPONSIBLE FOR ENSURING ALL NECESSARY PERMITS ARE OBTAINED PRIOR WATER CONVEYANCE. BUILDINGS ARE NOT PERMITTED IN THE EASEMENT AREA. ANY TRAFFIC CONTROL PLANS REQUIRED THROUGH A LEASE AGREEMENT MAY BE TO INSTALLATION OF FENCING. OTHER OBJECTS WHICH IMPEDE STORM WATER FLOW OR SYSTEM MAINTENANCE ARE DIFFERENT FROM THE ONE REQUIRED DURING THE LAND DEVELOPMENT PLAN REVIEW ALSO PROHIBITED. AND ARE SUBJECT TO REVISIONS. THE REVISED TRAFFIC CONTROL PLANS MUST BE g. ROADWAY MARKING, STRIPING, SIGNS AND OTHER TRAFFIC CONTROL DEVICES SHALL BE IN SUBMITTED AS PART OF THE LEASE AGREEMENT PROCESS FOR APPROVAL PRIOR TO ACCORDANCE WITH "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND 11. HIGH -DENSITY POLYETHYLENE (HDPE) STORM DRAINAGE PIPE INSTALLED WITHIN START OF R/W CLOSURES. CONTRACTOR SHALL CONTACT CDOT AT (704) 336-8348. HIGHWAYS" (MUTCD) AND SUBSEQUENT REVISIONS AND ADDENDUMS, AS PUBLISHED BY NCDOT EXISTING OR PROPOSED PUBLIC STREET RIGHT-OF-WAY MUST BE APPROVED BY THE AND CDOT. CITY'S INSPECTOR PRIOR TO ANY BACKFILL BEING PLACED. BACKFILL MATERIAL 25. CONSTRUCTION STAGING WITHIN CITY R/W LASTING MORE THAN 30 DAYS REQUIRES A MUST BE APPROVED BY THE CITY INSPECTOR PRIOR TO PLACEMENT OF THE R/W LEASE AGREEMENT. CONTRACTOR SHALL CONTACT CDOT AT (704) 336-8348. 10. UNLESS OTHERWISE INDICATED, ALL PAVEMENT MARKINGS SHALL BE PAINT INSTALLED PER MATERIAL WITHIN THE PUBLIC STREET RIGHT-OF-WAY. A NCDOT STD. SPEC. SECTION 1205. 26. PEDESTRIAN -SCALE LIGHTING AND/OR STREET LIGHTING SHALL NOT BE INSTALLED 12. MAINTAIN EACH STREAM, CREEK, OR BA WITHIN THE RIGHT-OF-WAY WITHOUT REVIEW AND APPROVAL OF CDOT. DEVELOPER 11. UNLESS OTHERWISE INDICATED, PARKING STALLS SHALL BE 4" WHITE LINES. AN UNOBSTRUCTED STATE CHANNEL AND BANKS OF TO CONTACT CANDACE INGE (704-336-3932 OR Candoce.inge@charlottenc.gov) FOR OGS, TIMBER, JUNK AND OTH LOCAL STREET LIGHTING CRITERIA WITH RESIDENTIAL SUBDIVISION PROJECTS AND TO 12. CONTRACTOR SHALL ADHERE TO ALL CONDITIONS AND PROVISIONS OF THE PROJECT PERMITS CONTACT ANTHONY MENDEZ .Mendez@chorlottenc. ov 704-336-3932 OR Anthon ( y g ) AND APPROVALS INCLUDING BUT NOT LIMITED TO DRIVEWAY PERMITS AND "APPROVED AS 13. "AS -BUILT" DRAWINGS AND PLANS OF THE STORM DRAINAGE SYSTEM, INCLUDING FOR ALL OTHER PROJECTS LIGHTING REQUIREMENTS. COORDINATE WITH DUKE ENERGY NOTED" COMMENTS. CONTRACTOR SHALL IMMEDIATELY REPORT ANY DISCREPANCIES BETWEEN DESIGNED DITCHES, MUST BE SUBMITTED PRIOR TO SUBDIVISION FINAL INSPECTION TO AND CDOT AS NECESSARY TO DETERMINE LIGHTING LEVELS, LIGHTING LAYOUT AND CONDITIONS/PROVISIONS AND CONSTRUCTION DOCUMENTS TO ENGINEER AND OWNER. THE CITY/COUNTY ENGINEERING DEPARTMENT IN ACCORDANCE WITH THE REQUIREMENTS FOR INSTALLATION. CITY/COUNTY SUBDIVISION ORDINANCE. 13. THE CONTRACTOR SHALL RESTORE OFF -SITE CONSTRUCTION AREAS TO EQUAL OR BETTER 27. CONTRACTOR SHALL VERIFY THAT ALL REQUIRED ENCROACHMENT PERMITS ARE IN CONDITION THAN EXISTED PRIOR TO COMMENCEMENT OF CONSTRUCTION. PCSO SUMMARY ORIGINAL PARCEL ID NUMBER 06705802 06705804 06705808 06705810 06705803 06705806 06705809 DEVELOPMENT TYPE: MULTI -FAMILY SUBJECT TO PCCO? Y/N YES WATERSHED: CENTRAL CATAWBA DISTURBED AREA (AC): 5.30 AC SITE AREA (AC): 4.70 AC EXISTING BUILT -UPON -AREA (SF): *125,452 SF EXISTING BUA TO BE REMOVED (SF): *125,452 SF EXISTING BUA TO REMAIN (SF): 0 SF PROPOSED NEW BUA (SF): 159,540 SF PROPOSED % BUA 77.9 % DENSITY (HIGH/LOW) HIGH TOTAL POST -PROJECT BUA FOR SITE: 159,540 SF DEVELOPMENT OR REDEVELOPMENT? DEVELOPMENT NATURAL AREA REQUIRED (AC): N/A NATURAL AREA PROVIDED (AC): N/A TOTAL STREAM BUFFER PROTECTED N/A ON -SITE (AC): 0 TRANSIT STATION AREA? Y/N YES DISTRESSED BUSINESS DISTRICT? Y/N YES MITIGATION TYPE (IF APPLICABLE) 1-YR VOL/10-YR PEAK NATURAL AREA MITIGATION? Y/N NO BUFFER MITIGATION? Y/N NO TOTAL PHOSPHOROUS MITIGATION? Y/N NO *125,452 SF OF EXISTING BUA PER 1978 AERIAL PHOTO 14. PRIOR TO INSTALLATION, PE SEALED SHOP DRAWINGS FOR UNDERGROUND DETENTION PLACE BEFORE WORKING IN ANY EASEMENTS AND RIGHT-OF-WAYS. CONTRACTOR ZONING CODE SUMMARY SYSTEMS MUST BE FURNISHED TO CITY OF CHARLOTTE ENGINEERING FOR APPROVAL. SHALL ADHERE TO ALL CONDITIONS AND PROVISIONS OF THE ENCROACHMENT 14. CONTACT THE UTILITY COMPANY TO RELOCATE ANY EXISTING UTILITY POLES. ALL EXISTING 06705802 06705803 DOCUMENTS. CONTRACTOR SHALL CONTACT BOB STALEY WITH CDOT AT FACILITIES WHICH CONFLICT WITH THE IMPROVEMENTS UNDER THE SCOPE OF THIS PROJECT 06705804 06705806 15. PRIOR TO CO, SURVEYOR SEALED AS -BUILT DRAWINGS OF UNDERGROUND DETENTION 704-432-1562 PRIOR TO CONSTRUCTION TO OBTAIN THE NECESSARY PERMITS FOR MUST BE RELOCATED AT THE EXPENSE OF THE APPLICANT. PROJECT NAME: MADISON ASHLEY PARK APARTMENTS 06705808 06705809 SYSTEMS MUST BE PROVIDED BY CONTRACTOR. ANY CONSTRUCTION ACTIVITIES WITHIN THE PUBLIC RIGHT OF WAY. 06705810 PROJECT ADDRESS: 2400 WILKINSON BLVD TAX PARCEL: 15. CONTRACTOR SHALL INSTALL PVC SLEEVES UNDER PAVED AREAS FOR UTILITY AND IRRIGATION 16. P -BUILT AND 28. ALL DEVELOPMENT CREATING A TOTAL OF 20,000 SQUARE FEET OF IMPERVIOUS AREA BEING INSTALLED AFTER PAVING OPERATIONS COMMENCE. COORDINATE WITH EACH UTILITY AND STORM OVI SINCE SEPTEMBER 1978 WILL REQUIRE STORM DRAINAGE DETENTION. IRRIGATION INSTALLER FOR NUMBER OF SLEEVES, LOCATION, AND SIZE REQUIRED. ALSO REFER OWNER: MADISON CAPITAL GROUP PHONE # - 17. PRIOR TO PLAT RECORDATION, OFFSITE R/W AND/OR CONSTRUCTION EASEMENTS ARE 29. TREES WITHIN THE STREET RIGHT OF WAY ARE PROTECTED BY LAW. A PERMIT IS TO ELECTRICAL SITE PLAN. OWNER ADDRESS: 6805 MORRISON BLVD, SUITE 250, CHARLOTTE, NO 28211 REQUIRED TO BE OBTAINED ACCORDING TO THE GUIDELINES OF THE "OFFSITE R/W REQUIRED FROM THE CITY ARBORIST AT (704) 336-5753 PRIOR TO THE REMOVAL OF 16. LANDSCAPE CONTRACTOR SHALL IS RESPONSIBLE FOR INSTALLING NECESSARY PVC SLEEVES ACQUISITION PROCESS". THESE NEEDED R/W AND CONSTRUCTION LIMITS ARE ANY RIGHT OF WAY TREES. ALL TREES OVER 8" IN DIAMETER AS MEASURED 4.5' PLANS PREPARED BY: ORSBORN ENGINEERING GROUP PHONE # (704) 749-1432 CLEARLY SHOWN ON THE ROADWAY IMPROVEMENT PLAN. ABOVE GROUND AND LOCATED WITHIN THE SETBACK ARE PROTECTED BY LAW. UNDER PAVED AREAS FOR IRRIGATION BEING INSTALLED AFTER PAVING OPERATIONS COMMENCE. GC SHALL COORDINATE PAVING SCHEDULE WITH LANDSCAPE CONTRACTOR TO ENSURE CONTACT LAND DEVELOPMENT AT (704) 336-6692 FOR REQUIRED PERMITS. INSTALLATION OF SLEEVES OCCURS PRIOR TO COMMENCEMENT OF PAVING OPPERATIONS. ZONING: TOD-NC JURISDICTION: CHARLOTTE 18. PER SECTION 18-175(e) OF CITY CODE AND SECTION 10.0 OF THE CITY'S POST CONSTRUCTION CONTROLS ADMINISTRATIVE MANUAL, ALL REQUIRED NATURAL AREAS 30. BEFORE YOU DIG STOP. CALL THE NO ONE -CALL CENTER AT 1-800-632-4949. 17. CONTRACTOR SHALL INSTALL PVC SLEEVES UNDER PAVED AREAS FOR UTILITIES BEING PROPOSED USE: MULTI FAMILY RESIDENTIAL AND/OR POST CONSTRUCTION CONTROLS EASEMENTS (PCCEs) MUST BE RECORDED IT'S THE LAW. INSTALLED AFTER PAVING OPPERATIONS COMMENCE. CONTRACTOR SHALL COORDINATE WITH �j Al PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. EACH UTILITY FOR NUMBER OF SLEEVES, LOCATION, AND SIZE REQUIRED. CON TRACTOR SHALL MAXIMUM BUILDING HEIGHT: 65 FEET PROPOSED BUILDING HEIGHT: 62.6 FEET 31. PRIVATE DEVELOPMENT UTILITY RELOCATION COORDINATION - FOR UTILITY REVIEW COMPLETE SET OF PLANS FOR COORDINATION BETWEEN CIVIL, ARCHITECTURAL,LANDSCAPE 19. THE DEVELOPER SHALL CONTACT THE IMPLEMENTATION SECTION MANAGER OF THE COORDINATION RELATED TO BOTH EXISTING UTILITY RELOCATION NEEDS AND . . MEPETCPRIOR TO CONSTRUCTION MAXIMUM BUILDING LENGTH: 500 FEET WITH ECONOMIC MOBILITY BONUS #2 CHARLOTTE DEPARTMENT OF TRANSPORTATION (CDOT) OR THEIR DESIGNEE AT PROPOSED NEW UTILITY INSTALLATIONS, PLEASE CONTACT RALPH TRUITT, CDOT ROW , , PROPOSED BUILDING LENGTH: 498.6 FEET; AFFORDABLE UNITS TO BE PROVIDED 704-336-4119 TO IDENTIFY ANY CONFLICTS WITH TRAFFIC SIGNALIZATION EQUIPMENT. UTILITY COORDINATOR AT 704-336-4248 OR rtruitt@charlottenc.gov. 18. CONTRACTOR SHALL REVIEW COMPLETE SET OF PLANS FOR COORDINATION BETWEEN CIVIL, 60- 90 DAYS WILL BE REQUIRED TO COORDINATE RELOCATION. DEVELOPER SHALL BE ARCHITECTURAL, LANDSCAPE, MEP, ETC. PRIOR TO CONSTRUCTION. RESPONSIBLE FOR ALL RELATED RELOCATION COST AND/OR ANY REPAIR COST 32. A JOINT USE MANHOLE (MEET -ME MANHOLE) IS TO BE PROVIDED BY THE DEVELOPER BUILDING COVERAGE: 113,213 SQ. FT. NUMBER OF UNITS: 253 NUMBER OF BEDROOMS: 320 CAUSED BY THE CONTRACTOR/DEVELOPER. TO ACCOMMODATE ALL UTILITY TELECOM SERVICE PROVIDERS. THE JOINT USE 19. ALL WALKS AND OTHER PAVED AREAS SHALL COMPLY WITH ADA CODE FOR LONGITUDINAL MANHOLE SHALL BE LOCATED ON PRIVATE PROPERTY OUTSIDE OF THE CITY SLOPE AND CROSS SLOPE. WALK SLOPES SHALL NOT EXCEED 5%, AND SHALL NOT EXCEED 2% LOT SIZE: 4.70 SO. FT./ACRES NUMBER OF BUILDINGS: 1 RIGHT-OF-WAY. CROSS SLOPE UNLESS OTHERWISE NOTED. YARD REQUIREMENTS: REQUIRED BUFFERS: /\ 1� \\ // I SETBACK (WILKINSON):30 FT. FROM FUT. BOO FRONT: NO / YES FT. R/W TO BE DEDICATED ZONING: R-5 ALONG ARTY AVENUE ZONING: B-1(CD) ZONING: R-5 SETBACK (BERRYHILL): 16 FT FROM FUT. ROC REAR: A/ YES FT. LP LP� LP - - - - - - - - - - - - - SETBACK (ARTY): 16 FT FROM PROP. BOC SIDE (L): NO /YES FT. PROPOSED 26' TYPE I MODIFIED DRIVEWAY 20' ACCESS EASEMENT 39 SURFACA PCCE PARKING SPACES 10'x10' SIGHT TRIANGLES ZL 28.5' PROP R/W ARTY AVENUE 20' EX R/W Al 20.5' PROPOSED Bgt / SIDE YARD: 0 FT. SIDE (R): (5/ YES FT. 6+00 5+00 4+100 (OTHER SECONDARY) 3,00 } 2+00 1+00 0 00 -0+70 REQUIRED SCREENING: Al F16' SETBACK FROM PROPOSED BOC T 't'J FUBLIC R/={CDOT) �\ �16' SETBACK FROM PROPOSED BOCK T T T T FRONT• 0 /YES ��j �' ■■■^■■■■■■■■■■■■I��■rIF �IIIIIIIIarm, ■r■r■■�� � I■Illlllilll IW g -1�iWMVfAF*4*63W'5 Eli / L law 44 II ® -1 • PARKING SPACESPARKING EQUIPMEN-T-;,, GARAGE Roo • 315 SPACES • III v 46' LOADING AREA m A1 LONG TERM BIKE STORAGE 24 SPACES MIN. a m 0 20' BUILD TO ZONE i SRI AMENITY COURTYARD 13,609 SF OPEN SPACE U CooMICAL I - - _ II I LEASE/AMENITY ILLx ROOM SPACE 25' PARKING TBACK k B SF _ DOG PARK 16' SETBACK FROM FUTURE BOC 4,548 SF OPEN T T SPACE - - - Z2' S/W ESMT - 20' BUILD TO ZONE LP OE _0 �E CLOSE EXISTING DRIVEWAYS LP LP L LP LP 30' SETBACK FROM FUTURE BOO CLOSE EXISTING DRIVEWAYS - - - 3 SHORT TERM BIKE _ _ _ _ X - 52' FUTURE BOO & FUTURE R/W ARKING SPACES f CLOSE EXISTING DRIVEWAYS WILKINSON BOULEVARD US-74 0 DRIO EWAYS TING- (6+ LANE BLVD.) 8 100' PUBLIC R/W (NCDOT) TRANSFORMERS PER DUKE EXISTING MEDIAN A1 ENERGY STANDARDS ROM III■III■ 0 O m LLJ o' LL 0 m LL Y 0 Q m Ld co n GW Of 0 REAR: AO / YES SIDE (L): NO /YES IJ5'x35' SIDE (R) NO / YES ARTY AVE. BERRYHILL RD. WILKINSON BLVD. (SECONDARY) (PRIMARY) (6+ LANE) BUILD TO PERCENTAGE 40% REQUIRED 80% REQUIRED 60% REQUIRED 86% PROVIDED 93% PROVIDED 68% PROVIDED BUILD TO ZONE 0'-20' 0'-20' 0'-20' SIGHT TRIANGLE O PARKING ONLY: NO /YES OPEN SPACE: I IMPERVIOUS COVERAGE: 159,540 CFD / ACRES REQUIRED: 10% = 0.47 AC INTERIOR LANDSCAPING: PROVIDED: 22,005 SF / 0.51 AC DOG PARK: 4,548 SF REQUIRED: 15,954 SO. FT., AMENITY COURTYARD: 13,609 SF COURTYARD 1: 1,839 SF PROVIDED: 45,192 SQ. FT. COURTYARD 2: 2,009 SF 1 PARKING DATA: AUTOMOBILE: NONE REQUIRED FOR TOD-NC ZONING 352 SPACES PROVIDED (37 SURFACE, 315 IN PARKING GARAGE, INCLUDING 8 ADA SPACES) MAXIMUM ALLOWED: 1.1 SPACES PER BEDROOM/320 UNITS = 352 SPACES (NOT INCLUDING ADA SPACES) BICYCLE:253 DWELLING UNITS/5 OR 30 MAX = 30 SPACES REQUIRED LONG TERM PARKING = 80% OF REQUIRED SPACES OR 24 MAX = 24 LONG-TERM SPACES REQUIRED 24+ LONG-TERM SPACES PROVIDED IN PARKING GARAGE 6 SHORT TERM SPACES REQUIRED - 7 SHORT TERM SPACES PROVIDED LOADING: 1 LOADING SPACE REQUIRED 1 LOADING SPACE PROVIDED I 30.6' EX R/W EXISTING SIDEWALK SOLID WASTE: DUMPSTER & RECYCLE LOCATIONS SHOWN ON PLANS. RECYCLING REQUIRED: 253 UNITS = 4 RECYCLING STATIONS 4 STATIONS AT 144 SF EACH = 576 SF TOTAL RECYCLING PROVIDED: 586 SF TOTAL 31.5' FUTURE TRASH COMPACTOR REQUIRED: 8 CY TRASH COMPACTOR/90 UNITS BOC TRASH COMPACTOR PROVIDED: 24+ CY TRASH COMPACTOR, (253 UNITS/90 UNITS) * 8 CY 39.5' FUTURE R/W LP �35'x35' SIGHT TRIANGLE - -100=x70' SIGHT TRIANGLE - f- GRAPHIC SCALE 40 0 20 40 80 160 ( IN FEET ) 1 inch = 40 ft. n 0 2 0 M a w (91 oo ;_ � W 00 M U 0 N r 0L W Z N Z W i Q ^ O Vlw O_jr,0 �tD Z`Ca 0z xu W J Ln O (0 W 2 � z Q 0L 0 J Q a Lu 0 0 J LL z J W w \ V) Q 0 0 Q z = 0 U 0 a O (V W � N z0 �00 0 oC J U CD on z - a J Q z w H Lh 0 oQ Q U 2u 00 o-\NCANo x- %. �•• �y\�NAL Cp�,Ao•• :-y � • o Q - C-3139 Z;�= Q. .�'4 N CAR .� O� � ,oFESS/� SEAL r c ; 028786 z C 01?-5 Ln z O V) V) U) � � z z w O O cr_ cc w w a d 0 0 w w N N N N Lu O M Q m 0 LID 00 0 0101010101010 0 0 JOB # 21002 DATE: 01/28/22 SCALE: 1" = 40' DRAWN BY: JAW APPROVED BY: JCO c2.0