Loading...
HomeMy WebLinkAboutWQ0003271_Monitoring - 06-2022_20220729 DWR - NonDischarge Monitoring Report Submittal NORTH CAROLINA ErwOranm@nlrtl Quafily Monitoring Report Submittal Permit Number#* WQ0003271 Name of Facility:* Hestron Park Month:* June Year:* 2022 Report Information Type* Upload Document* NDMR, NDAR-1, NDAR-2, NDMLR HP_DMR_Jun.pdf 121.7KB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR,GW-59). Confirmation Email Address:* stacy.goff@carolinawaterservicenc.com Name of Submitter:* Stacy Goff Signature: Date of submittal: 7/29/2022 This will be filled in automatically Initial Review Reviewer: Gerald,Wanda Is the project number correct?* WQ0003271 Is the monitoring report accepted?* Yes No Regional Office* Wilmington Reviewer: _anonymous Review Date: 8/16/2022 FORM: NDAR-2 05-16 NON-DISCHARGE APPLICATION REPORT (NDAR-2) Page of Did the application rates exceed the limits in Attachment B of your permit? EI Compliant 11 Non-Compliant If not a basin, were the sites kept free of vegetation and raked? ❑Compliant ❑Non-Compliant If not a basin, were there any instances of effluent ponding in or runoff from the sites? El Compliant ❑Non-Compliant If a basin, were there any instances of breakout from the berms? I]Compliant ❑Non-Compliant Was the onsite automatically activated standby power source tested and operational? a Compliant 7 Non-Compliant If the facility is non-compliant, please explain in the space below the reason(s)the facility was not in compliance. Provide in your explanation the date(s)of the non-compliance and describe the corrective action(s)taken.Attach additional sheets if necessary. Operator in Responsible Charge(ORC)Certification Permittee Certification ORC: Stacy A. Goff Permittee: Certification No.: 998882 Signing Official: Dana Hill Grade: 4 Phone Number: 252-808-5955 Signing Official's Title: Director of Operations Has the ORC changed since the previous NDAR-2? ❑Yes ]No Phone Number: 252-269-2540 Permit Exp.: 12/31/23 Digitally signed by Stacy A.Goff N:C=US,O=Carolina Water Service of NC,CN=Stacy A.Goff, Digitally signed by Dana Hill E=sta Off carolinawaterservicenc.com Dana I—I i I I DN: on:I the author CN=Dana Hill,E=dana.hill@carolinawaterservicenacom Stacy A. G o f g Reason .0 the author of this document Reason: am the author of this document Location:your signing location here Location:your signing location here Date:2022.07.27 08:57:02-04'00' Date:2022.07.26 19192004'00' Foxit PDF Editor Version:11.2.1 Foxit PDF Reader Version:11.2.1 Signature Date Signature Date By this signature,I certify that this report is accurrate and complete to the best of my knowledge. I certify,under penalty of law,that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted.Based on my inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information,the information submitted is,to the best of my knowledge and belief,true,accurate,and complete.I am aware that there are significant penalties for submitting false information,including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-2 05-16 NON-DISCHARGE APPLICATION REPORT (NDAR-2) Page of Permit No.: WQ0003271 I Facility Name: Hestron Park WWTP I County: Carteret I Month: June I Year: 2022 Site Name: 1 Site Name: 2 Site Name: Site Name: Area(acres): 0.18 Area(acres): 0.18 Area(acres): Area(acres): Fl YES C No Rate(GPD/ft2): 10 Rate(GPD/ft2): 10 Rate(GPD/ft2): Rate(GPD/ft2): Weather Freeboard Site Infiltrated? 0 YES Li NO Site Infiltrated? 0 YES ❑NO Site Infiltrated? ❑YES ❑NO Site Infiltrated? ❑YES ❑NO CDCD L 0 N Gl 3. 3. 3. 3. '0 7 0 y Q 0 Q y -a N C y -a N 0) '- C y -a 0) C y -a C U =° 61 u E E . v .a E o O E a v R >. E o 0 E a w 2 >, c o O E a v Si R >. c o 0 E ; v • 2 E ; 'v • rn 2 E Y =a .D 0 2 E 'a s 0 0 �, n ° o a Q o a - 0 1° v E o a - o f6 N E o a 1= = o R , E o a i- = o ad y E St n w o a, o a, o v o v E a CO R 0 (Ts > Q C -I , rn > Q c -I s- 0 > Q C -I , rn > a C -I s- 0 a) ~ d LL� lL CO lL CO lL m lL nT °F in ft ft gal min GPD/ft2 ft gal min GPD/ft2 ft gal min GPD/ft2 ft gal min GPD/ft2 ft 1 C 89 0 6,250 31 0.80 6,250 31 0.80 2 C 86 0 4,000 54 0.51 4,000 54 0.51 3 R 86 0.45 6,700 54 0.85 6,700 54 0.85 4 R 82 0.27 7,300 54 0.93 7,300 54 0.93 5 C 83 0 6,450 51 0.82 6,450 51 0.82 6 C 83 0 6,450 51 0.82 6,450 51 0.82 7 C 85 0 5,500 64 0.70 5,500 64 0.70 8 C 86 0 4,800 40 0.61 4,800 40 0.61 9 C 86 0 7,900 59 1.01 7,900 59 1.01 10 R 81 0.46 6,400 50 0.82 6,400 50 0.82 11 C 8 0 5,050 51 0.64 5,050 51 0.64 12 R 86 0.01 6,600 51 0.84 6,600 51 0.84 13 C 87 0 6,600 51 0.84 6,600 51 0.84 14 R 91 0.06 6,000 45 0.77 6,000 45 0.77 15 C 89 0 5,150 42 0.66 5,150 42 0.66 16 C 85 0 5,950 40 0.76 5,950 40 0.76 17 R 90 0.05 5,650 40 0.72 5,650 40 0.72 18 C 89 0 6,600 54 0.84 6,600 54 0.84 19 C 81 0 5,350 50 0.68 5,350 50 0.68 20 C 86 0 5,350 50 0.68 5,350 50 0.68 21 C 84 0 4,200 40 0.54 4,200 40 0.54 22 R 87 0.37 6,600 54 0.84 6,600 54 0.84 23 C 85 0 3,950 26 0.50 3,950 26 0.50 24 C 85 0 4,800 45 0.61 4,800 45 0.61 25 C 85 0 5,550 50 0.71 5,550 50 0.71 26 C 88 0 7,450 74 0.95 7,450 74 0.95 27 C 87 0 7,450 74 0.95 7,450 74 0.95 28 R 87 0.1 2,750 20 0.35 2,750 20 0.35 29 R 81 0.27 6,950 59 0.89 6,950 59 0.89 30 C 87 0 5,600 40 0.71 5,600 40 0.71 31 O 0 / / I I / 0.75 / 0.75 / #DIV/0. / #DIV/0. / Monthly LoadingGPDIft .;% / % / / / % / / % / Year to Date Loadin GPDIft ..% / % / / / / / / / FORM: NDMR 05-16 NON-DISCHARGE MONITORING REPORT(NDMR) Page of Sampling Person(s) Certified Laboratories Name: Stacy A. Goff Name: Environment 1, Inc#10 Name: Name: Carolina Water Services, Inc.- Eastern Region#5162 Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? iv.Compliant 17 Non-Compliant If the facility is non-compliant, please explain in the space below the reason(s)the facility was not in compliance. Provide in your explanation the date(s)of the non-compliance and describe the corrective action(s)taken.Attach additional sheets if necessary. See the Attached Operator in Responsible Charge(ORC)Certification Permittee Certification ORC: Stacy A. Goff Permittee: Certification No.: 998882 Signing Official: Dana Hill Grade: 4 Phone Number: 252-808-5955 Signing Official's Title: Director of Operations Has the ORC changed since the previous NDMR? ❑Yes ❑No Phone Number: 252-269-2540 Permit Expiration: 12/31/2023 Digitally signed by Stacy A.Goff DN:C=US,O=Carolina Water Service of NC,CN=Stacy A.Goff, Digitally signed by Dana HID ff E=slat. Off CarolinaWaterserViCenG COnI Rea on:I 0=CVVSNC,author CN=Dana Hill,E=dana.hill@carolinawaterservicenacom y g Reason: am the author of this document Stacy Reason am the author of this document Dana I Location your signing location here Location:your signing location here Date:2022.07.27 08:57:42-04'00' Date:2022.07.26 19:17:52-04'00' Foxit PDF Editor Version:11.2.1 Foxit PDF Reader Version:11.2.1 Signature Date Signature Date By this signature,I certify that this report is accurrate and complete to the best of my knowledge. I certify,under penalty of law,that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted.Based on my inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information,the information submitted is,to the best of my knowledge and belief,true,accurate,and complete.I am aware that there are significant penalties for submitting false information,including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDMR 05-16 NON-DISCHARGE MONITORING REPORT(NDMR) Page of Permit No.: WQ0003271 I Facility Name: Hestron Park WWTP I County: Carteret I Month: June I Year: 2022 PPI: 001 I Flow Measuring Point: ❑Influent -Effluent No flow generated I Parameter Monitoring Point: ❑Influent L. Effluent _Groundwater Lowering Surface Water Parameter Code - 50050 00310 00940 50060 31616 00610 00625 00620 00600 00400 00665 70300 00530 >_ E �; ar s w E fa t c Y c rn a •L (n .5 12 , L V O .O Y 43 IT R Y IT = ate L I " C -0 L > Q E o O o 0 o w != E o - o o 2 a o Q- O. c ._ C a, O 0 0 U ce U U Q Z Z a 5 W 24-hr hrs GPD mglL mglL mglL #1100 mL mglL mglL mglL mglL su mglL mglL mglL 1 14:28 1 12,500 1.9 7.84 2 08:10 1 8,000 8.8 8.03 3 11:12 1 13,400 8.8 6.63 4 07:05 1 14,600 5 12,900 6 13:22 1 12,900 4.7 7.95 7 15:00 1 11,000 1.7 7.87 8 10:56 1 9,600 5 7.79 9 15:10 1 15,800 4.8 7.52 10 12:00 1 12,800 3.1 7.47 11 10:00 1 10,100 12 13,200 13 14:48 1 13,200 3.5 7.62 14 15:16 1 12,000 2.5 7.87 15 11:19 1 10,300 8.6 7.87 16 13:50 1 11,900 8.8 7.99 17 13:43 1 11,300 1.7 7.91 18 15:15 1 13,200 19 10,700 20 14:12 1 10,700 1.7 7.9 21 15:29 1 8,400 2.1 2.4 <1 0.09 0.75 5.8 6.55 8.07 6.17 <2.5 22 15:03 1 13,200 1.2 7.92 23 10:23 1 7,900 8.8 8.06 24 10:23 1 9,600 8.3 7.93 25 11:39 1 11,100 26 14,900 27 13:45 1 14,900 1.7 7.7 28 07:30 1 5,500 8.8 7.89 29 11:17 1 13,900 8.8 7.94 30 07:27 1 11,200 8.8 7.99 31 Average: 11,690 2.10 5.20 1.00 0.09 0.75 5.80 6.55 6.17 0.00 Daily Maximum: 15,800 2.10 8.80 1.00 0.09 0.75 5.80 6.55 8.07 6.17 2.50 Daily Minimum: 5,500 2.10 1.20 1.00 0.09 0.75 5.80 6.55 6.63 6.17 2.50 Sampling Type: Recorder Composite Composite Grab Grab Composite Composite Composite Composite Grab Composite Composite Composite Monthly Limit: 67,000 10 14 4 20 Daily Limit: 43 6-9 Sample Frequency: Continuous Monthly 3 X Year 5 X Week Monthly Monthly Monthly Monthly Monthly 5 X Week Monthly 3 X Year Monthly