HomeMy WebLinkAboutNCG550321_Inspection_20220817DocuSign Envelope ID: 8CBD9BB6-9DF9-49EB-B94D-1BEC2482BBAC
ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
RICHARD E. ROGERS, JR.
Director
Elizabeth B. Pilson
2355 Ronald Scott Road
Bear Creek, NC 27207
Dear Ms. Pilson:
NORTH CAROLINA
Environmental Quality
August 17, 2022
Subject: Compliance Evaluation Inspection
Single Family Wastewater Treatment System
General NPDES Permit NCG550000
Certificate of Coverage NCG550321
Facility: 2355 Ronald Scott Road
Chatham County
On August 10, 2022, Alys Hannum from the Raleigh Regional Office visited your single-family
residence wastewater treatment system to evaluate compliance with the subject General National
Pollution Discharge Elimination System (NPDES) Permit. Your assistance during the inspection
was greatly appreciated.
Our records indicate the treatment system consists of a septic tank, sub -surface sand filter, tablet
chlorinator with chlorine contact chamber, and discharge pipe.
General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG550321 authorize
the discharge of domestic wastewater from your treatment system to receiving waters designated
as an unnamed tributary to Tysons Creek (class C) in the Cape Fear River Basin, in accordance
with the effluent limits and monitoring requirements established within the General Permit. The
following conditions were noted at your facility:
• Pumping the septic tank: You are required to inspect the septic tank at least yearly to
determine if solids must be removed or if other maintenance is necessary. Septic tanks
should be pumped out every five years or when the solids level is found to be more than
1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping
company can check the status periodically and determine when pumping is required. The
General NPDES Permit requires the permittee to retain records associated with sewage
disposal activities for a period of at least 5 years.
During the inspection, you stated that you did not have records of the last time the septic
tank had been pumped. Please contact a pumping company to determine if your septic
tank requires pumping and maintain a schedule of pumping the septic tank every five
years or when the solids level is greater than one-third of the liquid depth of the tank,
whichever is greater.
NORTH CAROLINA
Department of Environmental Quality
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609
919.791.4200
DocuSign Envelope ID: 8CBD9BB6-9DF9-49EB-B94D-1BEC2482BBAC
Elizabeth Pilson, NCG550321
August 17, 2022
Page 2 of 3
• Chlorine tablets in the chlorinator: You are reminded that it is required that chlorine
tablets be maintained in the chlorinator to ensure proper disinfection of the discharged
wastewater. Chlorine tablets provide effective disinfection and prevent/limit harmful
bacteria from discharging to the environment. The product label for these tablets must
indicate the tablets are approved for wastewater use and not for swimming pools. Part 1,
Section D (1) of General NPDES Permit NCG550000 requires the permittee to inspect
the tablet chlorinator weekly to ensure there is an adequate supply of tablets for
continuous and proper operation.
The inspector did not observe any chlorine tablets in the chlorinator. Please ensure the
correct type of tablets are used and maintained in the chlorinator as required by the
General NPDES Permit.
• Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements,
within General Permit NCG550000 requires a permittee to sample and analyze the
effluent leaving his/her treatment system prior to discharge annually. Parameters to be
sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total
Suspended Solids, Fecal Coliform and Total Residual Chlorine.
During the inspection, you informed the inspector that the effluent has not been
monitored within the last 12 months because there has been no flow through the system.
If the system does begin to flow, please collect a representative sample of the effluent,
have it analyzed by a certified commercial laboratory and submit the results to this
office. Failure to monitor the effluent discharge as required is a violation of NPDES
General Permit NCG550000.
• Discharge outlet location. The permittee is required to conduct a visual review of the
outfall location at least twice each year (one at the time of sampling) to ensure that no
visible solids or other obvious evidence of system malfunctioning is observed. Any
visible signs of a malfunctioning system shall be documented and steps taken to correct
the problem.
The discharge pipe was visible and accessible the day of the inspection. Please continue
to ensure the outlet is always visible/maintained and cleared of vegetation, soil and
leaves.
The annual fee ($60 per year) for the period November 1, 2021, through September 30, 2022,
was due by November 2, 2021. This fee has not been paid and is overdue. Payment in the
amount of $60 must be remitted to the Division as indicated on the attached Annual Permit
Fee Invoice.
GD_E
NORTH CAROLINA
Department of Environmental Quality
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609
919.791.4200
DocuSign Envelope ID: 8CBD9BB6-9DF9-49EB-B94D-1BEC2482BBAC
Elizabeth Pilson, NCG550321
August 17, 2022
Page 3 of 3
Please continue to periodically inspect the wastewater treatment system to ensure the treatment
components are always maintained and in good operating order. You are also reminded to
maintain all monitoring data and associated maintenance records onsite for a minimum of three
years for inspection.
Within 30-days receipt of this letter, please submit a written response to this office indicating
the actions you will take or have taken to comply with or resolve the issues noted above.
If you have questions or comments about this inspection or the requirements to take corrective
action, please contact me at vanessa.manuel@ncdenr.gov, or by phone at 919-791-4232.
Sincerely,
DocuSigned by:
Fkuiu.ssa Ataulta,
B2916E6AB32144F...
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachment(s): EPA Water Compliance Inspection Report
Annual Permit Fee Invoice — Due November 2, 2021
cc: Laserfiche
NORTH CAROLINA
Department of Environmental Quality
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609
919.791.4200
DocuSign Envelope ID: 8CBD9BB6-9DF9-49EB-B94D-1BEC2482BBAC
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
1
21IIIIII
671
Transaction Code
IN I 2 IL
NPDES yr/mo/day Inspection
I 3 I NCG550321 111 121 22/08/10 117
Type
1810I
IIIIIIIIIII
Inspector Fac Type
19I S I 2011
IIIIIIIIIII IIIIIII I IIIIII
P6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
I 70I3 I 711 1 72 I N I 73I 1 74 71
I I
I I I I I I 180
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES oermit Number)
2355 Ronald Scott Road
2355 Ronald Scott Rd
Bear Creek NC 27207
Entry Time/Date
11:OOAM 22/08/10
Permit Effective Date
20/12/10
Exit Time/Date
11:30AM 22/08/10
Permit Expiration Date
25/10/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Elizabeth B Pilson,8440 NC Hwy 42 Bear Creek NC 27207//336-581-4238/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Operations & Maintenar Self -Monitoring Progran
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s)
Alys K Hannum
of Inspector(s) Agency/Office/Phone and Fax Numbers Date
c- DocuSigned by:
DWR/RRO WQ/919-791-4255/ 8/16/2022
bar..uvrw
"-4C22170C5AA04F3...
Signature
of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
DocuSigned by:
8/16/2022
Vatn.t,SSa f. haln l t ,
B2916E6AB32144F.
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page# 1
DocuSign Envelope ID: 8CBD9BB6-9DF9-49EB-B94D-1BEC2482BBAC
NPDES yr/mo/day
31 NCG550321 111 121 22/08/10
I17
Inspection Type
18LI
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page# 2
DocuSign Envelope ID: 8CBD9BB6-9DF9-49EB-B94D-1BEC2482BBAC
Permit: NCG550321
Inspection Date: 08/10/2022
Owner - Facility: 2355 Ronald Scott Road
Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El El
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Septic Tank
(If pumps are used) Is an audible and visual alarm operational?
Is septic tank pumped on a schedule?
Are pumps or syphons operating properly?
Are high and low water alarms operating properly?
Comment: Homeowner did not retain records of septic pumping.
Sand Filters (Low rate)
(If pumps are used) Is an audible and visible alarm Present and operational?
Is the distribution box level and watertight?
Is sand filter free of ponding?
Is the sand filter effluent re -circulated at a valid ratio?
# Is the sand filter surface free of algae or excessive vegetation?
# Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1)
Comment:
Yes No NA NE
❑ ❑ • ❑
• ❑ ❑ ❑
❑ ❑ • ❑
Yes No NA NE
❑ ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ •
• ❑ ❑ ❑
❑ ❑ ❑ •
Disinfection -Tablet Yes No NA NE
Are tablet chlorinators operational? • ❑ ❑ ❑
Are the tablets the proper size and type? ❑ • ❑ ❑
Number of tubes in use? 2
Is the level of chlorine residual acceptable? ❑ ❑ ❑ •
Is the contact chamber free of growth, or sludge buildup? • ❑ ❑ ❑
Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ •
Comment: Homeowner did not have chlorine tablets.
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Page# 3
DocuSign Envelope ID: 8CBD9BB6-9DF9-49EB-B94D-1BEC2482BBAC
Permit: NCG550321
Inspection Date: 08/10/2022
Owner - Facility: 2355 Ronald Scott Road
Inspection Type: Compliance Evaluation
Effluent Sampling
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Comment: No discharge.
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Page# 4
DocuSign Envelope ID: 8CBD9BB6-9DF9-49EB-B94D-1BEC2482BBAC
NORTH CAROLINA DEPARTMENT OF
ENVIRONMENTAL QUALITY
INVOICE
Annual Permit Fee
Overdue
This annual fee is required by the North Carolina Administrative Code. It covers the administrative costs associated with
your permit. It is required of any person holding a permit for any time during the annual fee period, regardless of the facili
operating status. Failure to pay the fee by the due date will subject the permit to revocation. Operating without a valid
permit is a violation and is subject to a $10,000 per day fine. If the permit is revoked and you later decide a permit is
needed, you must reapply, with the understanding the permit request may be denied due to changes in environmental,
regulatory, or modeling conditions.
Invoice Number: 2021 PR008597
Permit Number: NCG550321
Chatham County
2355 Ronald Scott Road
Elizabeth B. Pilson
8440 NC Hwy 42
Bear Creek, NC 27207
Annual Fee Period: 2021-10-01 to 2022-09-30
Invoice Date: 09/02/2021
Due Date: 10/02/2021
Annual Fee: $60.00
Notes:
1. You may pay either by mail with check/money order OR by electronic payment (eCheck or Credit Card).
2. If payment is by check/money order, please remit payment to:
NCDEQ - Division of Water Resources
Attn: Animal/Discharge/Non-Discharge Billing
1617 Mail Service Center
Raleigh, NC 27699-1617
3. If payment is electronic, please see https://deq.nc.gov/epavments/wq to pay electronically. Payments by eCheck will debit your
checking account. Credit card transactions will incur a convenience fee.
4. Please include your Permit Number and Invoice Number on all correspondence.
5. A $25.00 processing fee will be charged for returned checks in accordance with North Carolina General Statute 25-3-512.
6. Non -Payment of this fee by the payment due date will initiate the permit revocation process.
7. Should you have any questions regarding this invoice, please contact the Annual Administering and Compliance Fee
Coordinator at 919-707-3698.
(Return This Portion With Check)
ANNUAL PERMIT INVOICE
Overdue
Invoice Number: 2021 PR008597
Permit Number: NCG550321
Chatham County
2355 Ronald Scott Road
Elizabeth B. Pilson
8440 NC Hwy 42
Bear Creek, NC 27207
Annual Fee Period: 2021-10-01 to 2022-09-30
Invoice Date: 9/2/2021
Due Date: 10/2/2021
Annual Fee: $60.00
Check Number: