Loading...
HomeMy WebLinkAboutSWA000160_Plansheet (C0.0) - Cover Sheet_20220812N N 0 N Z W 0-1 J 0 U) LU O N (D U) �I U) c Cz 0 M 0 Q 0 U_ N _o 00 CO ti r` U aD 0 n c LU U) I�� tx rn. Wlvts sch Jx • Of Nursin ,yr .14. c _ - SITE Etlerb 'reek ,�147 N VICINITY MAP NOT TO SCALE N AERIAL VIEW OF SITE NOT TO SCALE lta -) SL1njjy=Side Drl f! 1 j L-LZ i�l c r•1 N CITY GIS / ZONING MAP NOT TO SCALE 4 101jum W 1 OWNER / DEVELOPER CATALYST CAPITAL C/O MICHAEL COCCO 1554 N. BEVERLY DRIVE BEVERLY HILLS, CA 90210 PH: 484.547.5530 EMAIL: MCOCCO@CATALYSTCAP.COM ARCHITECT HSE ARCHITECTS 914 N. BROADWAY, SUITE 200 OKLAHOMA CITY, OK 73102 405.526.1303 UTILITIES ELECTRIC: DUKE ENERGY NATURAL GAS WATER & SEWER: CITY OF DURHAM PHONE / CABLE / ETC... T.B.D. 100% SUBMITTAL LEVEL 4 SITE PLAN PIN NUMBER 0812-58-42-0339 3114 CROASDAILE DRIVE DURHAM, NC 27705 DURHAM COUNTY, NC 60 0 30 60 120 ( IN FEET) 1 inch = 60ft. CIVIL ENGINEER CES GROUP ENGINEERS, LLP FIRM LICENSE #: F-1240 274 N. HWY. 16, SUITE 300 DENVER, NC 28037 PH: 704.489.1500 LANDSCAPE ARCHITECT CES GROUP ENGINEERS, LLP FIRM LICENSE #: F-1240 274 N. HWY. 16, SUITE 300 DENVER, NC 28037 PH: 704.489.1500 LAND SURVEYOR CES GROUP ENGINEERS, LLP FIRM LICENSE #: F-1240 274 N. HWY. 16, SUITE 300 DENVER, NC 28037 PH: 704.489.1500 SHEETINDEX Sheet Number Sheet Title C0.0 COVER SHEET C1.0 EXISTING CONDITIONS C1.1 DEMOLITION & EROSION CONTROL PHASE 1 C2.0 EROSION CONTROL PHASE 2 C3.0 SITE PLAN C4.0 UTILITY PLAN C5.0 FINAL GRADING PLAN C5.1 BMP PLAN AND DETAILS C6.0 DRAINAGE AREAS C7.0 LANDSCAPE PLAN C7.1 LANDSCAPE NOTES AND DETAILS C8.0 EROSION CONTROL DETAILS C8.1 EROSION CONTROL DETAILS C9.0 SITE DETAILS C9.1 SITE DETAILS C10.0 DRAINAGE DETAILS A LITY SITE DATA TABLE PROPERTY IDENTIFICATION NUMBER'S: 0812-58-42-0339 ZONING: OI DEVELOPMENT TIER: SUBURBAN WATERSHED: N/A OVERLAY DISTRICTS: N/A RIVER BASIN: NEUSE CURRENT USE : OFFICE PROPOSED USE: MEDICAL OFFICE BUILDING CURRENT IMPERVIOUS: 112,041 SF PROPOSED IMPERVIOUS: 118, 915 SF (73.0%) PARKING DATA: 1 PER 250 SF GFA 34,950 SF / 250 = 140 SPACES 5 ADA SPACES (1 VAN ACCESSIBLE SPACE) EXISTING PARKING: 182 TOTAL 7 ADA SPACES (3 VAN ACCESSIBLE) 0 BICYCLE SPOTS PROVIDED PARKING: 201 TOTAL (54 EXISTING SPACES RETAINED) 12 ADA SPACES (4 VAN ACCESSIBLE) 8 BICYCLE SPOTS (4 BICYCLE RACKS) TREE COVERAGE DATA: DISTURBED AREA: 0.85 ACRES EXISTING TREE COVERAGE AREA: 0.48 AC TREE COVERAGE AREA REMOVED: -0.34 AC PRESERVED TREE COVERAGE AREA: = 0.14 AC (29.1 %) PRESERVED TREE COVERAGE AREA REQUIRED: 10% (0.085 AC) PRESERVED TREE COVERAGE AREA PROVIDED: 16.5% (0.14 AC) BUILDING SQUARE FOOTAGE: 34,950 SF CITY OF DURHAM FIRE NOTES: SAFEGUARDS DURING THE CONSTRUCTION, ALTERATION, OR DEMOLITION OF STRUCTURES SHOWN ON THIS SITE PLAN SHALL BE IN ACCORDANCE WITH CHAPTER 33 OF THE 2018 NORTH CAROLINA FIRE CODE AND NFPA241 (2013 EDITION). A SPECIAL CONDITIONS OF APPROVAL 1. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, MAKE A PAYMENT IN LIEU FEE FOR SIDEWALK TO THE CITY OF DURHAM THROUGH THE PUBLIC WORKS DEPARTMENT IN THE AMOUNT OF $26,435 (406.65LF X $65.00/LF). STAMPING AREA rD2200052 PUBLIC WORKS CONDITIONS OF APPROVAL 1. THE DESIGNING PROFESSIONAL (A NCPE, NCPLS, OR NCRLA - AS REQUIRED) SHALL SUBMIT THREE (3) SETS OF CONSTRUCTION DRAWINGS TO THE PUBLIC WORKS DEPARTMENT - DEVELOPMENT REVIEW FOR REVIEW AND APPROVAL. CONSTRUCTION DRAWING APPROVAL IS REQUIRED PRIOR TO COMMENCING CONSTRUCTION (SEE CONSTRUCTION PLAN APPROVAL PROCESS). THE APPROVAL OF CONSTRUCTION DRAWINGS IS SEPARATE FROM SITE PLAN APPROVAL. CITY OFFICIALS SHALL REVIEW ALL SIZES, MATERIALS, SLOPES, LOCATIONS, EXTENSIONS AND DEPTHS FOR ALL PROPOSED UTILITIES (WATERLINES, SANITARY SEWER LINES, AND STORM DRAINAGE CONVEYANCE SYSTEMS) FOR COMPLIANCE WITH ALL APPLICABLE REGULATORY STANDARDS, SPECIFICATIONS, AND BEST MANAGEMENT PRACTICES. 2. THE DESIGNING PROFESSIONAL (A NCPE, NCPLS, OR NCRLA - AS REQUIRED) SHALL SUBMIT ONE (1) SET OF AS -BUILT DRAWINGS TO THE PUBLIC WORKS DEPARTMENT REVIEW OF REVIEW AND APPROVAL. AS -BUILT DRAWING APPROVAL IS REQUIRED PRIOR TO WATER METER INSTALLATION AND/OR SANITARY SEWER SERVICE CONNECTION AND PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 3. PIPES AND/OR STRUCTURES SHOWN IN THE EROSION CONTROL PLAN OF THE SITE PLAN THAT ARE PROPOSED TO BE PERMANENT WILL BE REVIEWED AND APPROVED AS PART OF THE GRADING PLAN DURING CONSTRUCTION DRAWING REVIEW. THESE PIPES AND/OR STRUCTURES MAY NOT BE INSTALLED PRIOR TO CONSTRUCTION DRAWING APPROVAL AND PAYMENT OF INSPECTION FEES. GENERAL CONDITIONS OF APPROVAL 1. SOLID WASTE CONTAINMENT CAPACITY AND COLLECTION FREQUENCY WILL BE SUFFICIENT TO PREVENT THE ILLEGAL PLACEMENT OF TRASH AND RECYCLABLES. 2. PINE STRAW SHALL NOT BE USED AS MULCH OR GROUNDCOVER WITHIN TEN FEET OF ANY STRUCTURES CONSISTING OF EXTERIOR COMBUSTIBLE CONSTRUCTION AS SPECIFIED BY DURHAM CITY CODE SECTION 46-87. 3. ALL SITE IMPROVEMENTS, INCLUDING LANDSCAPING, MUST BE IN PLACE PRIOR TO THE ISSUANCE OF A CERTIFICATE OF COMPLIANCE. CONTACT THE DURHAM CITY -COUNTY PLANNING DEPARTMENT SITE COMPLIANCE STAFF TO SCHEDULE AN INSPECTION. SITE COMPLIANCE INSPECTION FEES MUST BE RECEIVED BY THE DURHAM CITY -COUNTY PLANNING DEPARTMENT PRIOR TO SCHEDULING AN INSPECTION. IF A RE -INSPECTION IS REQUIRED, AN ADDITIONAL INSPECTION FEE MUST BE RECEIVED BY THIS OFFICE PRIOR TO THE RE -INSPECTION. 4. THESE STANDARDS MUST BE VERIFIED BY A LANDSCAPE COMPLIANCE FORM COMPLETED BY A PROFESSIONAL LANDSCAPE ARCHITECT OR LICENSED LANDSCAPE CONTRACTOR PRIOR TO THE CERTIFICATE OF COMPLIANCE BEING ISSUED. SUBMIT TO THE DURHAM CITY -COUNTY PLANNING DEPARTMENT SITE COMPLIANCE STAFF WHEN SCHEDULING A SITE COMPLIANCE INSPECTION. 1. BED AND HOLE PREPARATION: a. TREATMENT WAS ADDED ONLY PER RECOMMENDATIONS, BASED ON SOIL TESTS; SOIL TEST RESULTS ARE ATTACHED, IF APPLICABLE b. TREE HOLES AND PLANTING BEDS HAVE BEEN TESTED FOR INFILTRATION c. THERE WAS NO LANDSCAPE FABRIC USED ON SITE d. SOIL IS FRIABLE AND DRAINS AT A DEPTH OF 2' FOR TREE PLANTING AREAS 2. TREE PREPARATION: a. THE ROOT COLLAR OF ALL TREES HAS BEEN EXPOSED AND IS FREE FROM SOIL, DEBRIS AND MULCH b. GIRDLING ROOTS HAVE BEEN CUT AWAY FROM THE TRUNK AND CORRECTED WITHIN THE PLANTING MIX 3. TREE INSTALLATION: a. TREES ARE INSTALLED WITH ROOT COLLARS EXPOSED AND COMPLETELY ABOVE GRADE b. TREES AND PLANTS WERE WATERED WITHIN TWO DAYS OF INSTALLATION c. MULCH HAS BEEN INSTALLED WITHIN A WEEK OF INSTALLATION d. STAKES WERE ONLY INSTALLED TO ADDRESS SPECIFIC ISSUES PERMITTED IN THE LANDSCAPE MANUAL 4. TREES HAVE BEEN VERIFIED TO BE THE SAME SPECIES AND CULTIVAR AS LISTED ON PLANS. ANY SUBSTITUTIONS, (IN ACCORDANCE WITH THE LANDSCAPE MANUAL), IF APPLICABLE, ARE ATTACHED. 5. RESULTS OF SOIL TESTS FOR EACH AREA OF DIFFERENT VEGETATION INSTALLATION, IF APPLICABLE, ARE ATTACHED. 6. RATES OF CHEMICAL MODIFICATIONS (TO PH AND FERTILITY ADJUSTMENTS), IF APPLICABLE, ARE ATTACHED. 5. TREE PROTECTION FENCE CONSTRUCTED OF A MATERIAL RESISTANT TO DEGRADATION BY SUN, WIND, AND MOISTURE FOR THE DURATION OF THE CONSTRUCTION, MUST BE IN PLACE PRIOR TO ANY DEMOLITION, LAND DISTURBANCE, OR ISSUANCE OF A GRADING PERMIT. SUCH FENCING SHALL BE MOUNTED ON METAL POSTS PLACED NO FURTHER THAN 10 FEET APART. SILT FENCING SHALL NOT SERVE AS TREE PROTECTION FENCING. WARNING SIGNS SHALL BE POSTED AT EACH END OF THE TREE PROTECTION FENCE WITH PERIMETER SIGNS SPACED A MAXIMUM OF 100 FEET ON CENTER THEREAFTER. EACH SIGN SHALL READ: "NO TRESPASSING/TREE PROTECTION AREA" AND "PROHIBIDO ENTRAR / ZONA PROTECTORA PARA LOS ARBOLES." 6. SHALL BE ESTABLISHED AROUND ALL TREES TO BE PRESERVED. THE ROOT PROTECTION ZONE SHALL EITHER BE A SIX-FOOT RADIUS AROUND A TREE OR ONE FOOT OF RADIUS FOR EVERY INCH OF DIAMETER AT BREAST HEIGHT (DBH) OF EXISTING TREES, WHICHEVER IS GREATER. 7. AT THE START OF GRADING INVOLVING THE LOWERING OF EXISTING GRADE AROUND A TREE OR STRIPPING OF TOPSOIL, A CLEAN, SHARP, VERTICAL CUT SHALL BE MADE AT THE EDGE OF THE TREE SAVE AREA PRIOR TO OR AT THE SAME TIME AS OTHER EROSION CONTROL MEASURES ARE INSTALLED. THE TREE PROTECTION FENCING SHALL BE INSTALLED ON THE SIDE OF THIS CUT FARTHEST AWAY FROM THE TREE TRUNK AND SHALL REMAIN IN PLACE UNTIL ALL CONSTRUCTION IN THE VICINITY OF THE TREES IS COMPLETE. NO STORAGE OF MATERIALS, DUMPING OF WASTE, FILL, OR PARKING OF EQUIPMENT SHALL BE ALLOWED WITHIN THE ROOT PROTECTION ZONE AND NO TRESPASSING SHALL BE ALLOWED WITHIN THE BOUNDARY OF THE ROOT PROTECTION ZONE. 8. THE MAXIMUM ILLUMINATION PERMITTED AT THE END OF A PROPERTY LINE SHALL BE AS SET FORTH BELOW. WHERE A DEVELOPMENT IS UNIFIED WITH SHARED PARKING OR OTHER MEASURE SHOWN ON A SITE PLAN, THE MAXIMUM ILLUMINATION LEVELS SHALL APPLY ONLY TO THE EXTERIOR LOT LINES OF THE PROJECT (ANY INTERIOR LOT LINES SHALL BE EXEMPT FROM THIS PARAGRAPH). 1. THE MAXIMUM ILLUMINATION AT THE EDGE OF THE PROPERTY LINE ADJACENT TO A RESIDENTIAL ZONING DISTRICT IS 0.5 FOOT-CANDLES. 2. THE MAXIMUM ILLUMINATION AT THE EDGE OF THE PROPERTY LINE ADJACENT TO A NONRESIDENTIAL ZONING DISTRICT IS 5.0 FOOT-CANDLES. 3. THE MAXIMUM ILLUMINATION AT THE EDGE OF THE PROPERTY LINE ADJACENT TO A STREET IS 5.0 FOOT-CANDLES. e. THE LEVEL OF ILLUMINATION AS MEASURED IN FOOT-CANDLES AT ANY ONE POINT SHALL MEET THE STANDARDS IN THE TABLE IN UDO SECTION 7.4 WITH MINIMUM AND MAXIMUM LEVELS MEASURED ON THE PAVEMENT WITHIN THE LIGHTED AREA. f. THE MAXIMUM HEIGHT FOR DIRECTIONAL OR FULL CUT-OFF LIGHTING FIXTURES (FIXTURES DESIGNED TO INSURE THAT NO LIGHT IS EMITTED ABOVE A HORIZONTAL LINE PARALLEL TO THE GROUND) SHALL BE 30 FEET ABOVE GRADE. g. THE MAXIMUM HEIGHT FOR NON -DIRECTIONAL LIGHTING FIXTURES, WHICH ARE DEFINED AS FIXTURES DESIGNED TO ALLOW LIGHT TO BE EMITTED ABOVE A HORIZONTAL LINE PARALLEL TO THE GROUND, SHALL BE 15 FEET ABOVE GRADE. NON -DIRECTIONAL LIGHTING FIXTURES SHALL BE TRANSLUCENT OR HAVE BAFFLES TO PREVENT VIEWS OF THE LIGHT SOURCE. In. UNDER -CANOPY LIGHTING SHALL BE RESTRICTED TO LIGHTING FIXTURES (INCLUDING LENSES) THAT DO NOT PROJECT BELOW THE BOTTOM OF THE CANOPY. i. LIGHTING SHALL BE ORIENTED NOT TO DIRECT GLARE OR EXCESSIVE ILLUMINATION ONTO STREETS IN A MANNER THAT MAY DISTRACT OR INTERFERE WITH THE VISION OF DRIVERS ON SUCH STREETS. j. THESE STANDARDS MUST BE VERIFIED BY FIELD SURVEY (BY USE OF PHOTOMETRIC SURVEY) PRIOR TO THE CERTIFICATE OF COMPLIANCE BEING ISSUED. ALL OF THIS INFORMATION, INCLUDING DETAILS, WILL BE REQUIRED ON BUILDING PLANS PRIOR TO ISSUANCE OF A BUILDING PERMIT. ENGINEERS PLANNERS SURVEYORS SCIENTISTS CES Group Engineers, LLP NC FIRM LICENSE #F-1240 274 N. Hwy. 16, SUITE 300 DENVER, NC 28037 T 704. 489.1500 www.ces-group.net SEAL- ,,,,,1 11 1 II11,0000 �O oFSSS/ - AL - 041342 $ - �fNIN�EP w=�` M. co �,.• � 1111111111x`\ SUBMITTALS DATE: PURPOSE: 12/01/2021 75% VA SUBMITTAL 12/28/2021 100% VA SUBMITTAL 02/07/2022 FIRST PERMIT SUBMITTAL 04/21/2022 SECOND PERMIT SUBMITTAL 7/19/2022 THIRD PERMIT SUBMITTAL Ln C:) o o ti O 0')CV N 0v J U Z O UU) U_jJ W = Q = 0- 2 Cy')iY O L OJ w AWL 0 W O U m � C0 w < of J W 't Q 0 > 0 w z �-� 0 = w C LU J_ O U} a J � C Q Q 07 W U) <W O Uz U It u7 L0 Q � M PROJECT NO: 7768 - 1021 CD DRAWING REVISIONS NO REVISION DESC DATE 1 CITY COMMENTS 04/21/202 3 CITY COMMENTS 07/19/202 DRAWN BY: SC REVISED BY: SC CHECKED BY: DL ISSUED BY: SC DRAWING TITLE: COVER SHEET DRAWING NUMBER- ■ Copyright 2021 CES Group Engineers, LLP