SENT VIA ELECTRONIC MAIL ONLY: NO HARD COPY WILL BE MAILED
August 16, 2022
Barbara Salk
Bear Lake Investments, LLC
Emailed to: barbara@bsmartdevelopment.com
SUBJECT: Compliance Inspection Report
Bear Lake Reserve WWTP
Non-discharge Permit No. WQ0029233
Jackson County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the Bear Lake Reserve
WWTP on 8/04/2022. This inspection was conducted to verify that the facility is operating in
compliance with the conditions and limitations specified in Non-discharge Permit No. WQ0029233. The
findings and comments noted during this inspection are provided in the enclosed copy of the inspection
report entitled "Compliance Inspection Report".
There were no significant issues or findings noted during the inspection and therefore, a response to this
inspection report is not required. As mentioned on the inspection report, please be sure to submit the
appropriate forms regarding change in ownership of the property.
If you should have any questions, please do not hesitate to contact Melanie Kemp with the Water
Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500 or via email at
melanie.kemp@ncdenr.gov.
Sincerely,
Melanie Kemp, Environmental Specialist I
Water Quality Regional Operations Section
Asheville Regional Office
Division of Water Resources, NCDEQ
ATTACHMENTS: Compliance Evaluation Inspection
E.c.: LF
Cc: Bob Barr – RPB Systems
Mike Whitmer – Community Association Manager, Bear Lake Reserve
DocuSign Envelope ID: 5741B5DD-6121-4C8D-9B60-189AE800531F
Compliance Inspection Report
Permit:WQ0029233 Effective:10/29/19 Expiration:07/31/25 Owner :Boto NC Properties LLC
SOC:
Contact Person:
Region:
County:
Directions to Facility:
Jackson
Asheville
Tara Cura
Effective:Expiration:Facility:Bear Lake Reserve WWTP
412 Lake Forest Dr
Tuckasegee NC 28783
Title:Phone:214-239-5225
I-40 W to Hwy. 19/23 to Sylva. Take Hwy. 107 past WCU. At intersection of Hwy. 107 & Hwy. 281 cross bridge and left onto Shook
Cove Rd. Bear Lake is at end of road (follow signs).
Kenneth Jason Rummel 1010634 828-785-3769
Secondary ORC(s):
828-251-1900Phone:24262Certification:Robert P BarrPrimary ORC:
SI,WW2,System Classifications:
On-Site Representative(s):
Related Permits:
Secondary Inspector(s):
Primary Inspector:
Inspection Date:Exit Time:Entry Time:
Phone:
08/04/2022 01:00PM 02:00PM
Melanie Kemp
Mikal Willmer
Facility Status:
Permit Inspection Type:
Reason for Inspection:Inspection Type:
Not CompliantCompliant
Routine
Reclaimed Water
Compliance Evaluation
Question Areas:
Treatment Flow Measurement-Effluent Treatment Flow Measurement-Influent Miscellaneous Questions
Treatment Flow Measurement-Water
Use Records
Treatment Treatment Barscreen
Treatment Filters Record Keeping Treatment Activated Sludge
Treatment Influent Pump Station Treatment Clarifiers Treatment Disinfection
Treatment Flow Measurement Treatment Return pumps End Use-Reuse
Standby Power
(See attachment summary)
Page 1 of 7
DocuSign Envelope ID: 5741B5DD-6121-4C8D-9B60-189AE800531F
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0029233
08/04/2022 Compliance Evaluation
Boto NC Properties LLC
Routine
Inspection Summary:
Melanie Kemp and Mikal Willmer, with the Asheville Regional Office, conducted a Compliance Evaluation Inspection of the
Bear Lake Reserve WWTP on August 4, 2022. This inspection was conducted to determine if the facility is being operated
and maintained in compliance with Permit No. WQ0029233. Jason Rummel, Bob Barr (ORC), and Jeff with RBP Systems,
as well as Mike Whitmer (Community Association Manager for Bear Lake) were present and assisted with the inspection. A
summary with comments and recommendations from the inspection is below.
Historically, Bear Lake Reserve WWTP has had very limited seasonal flow. The facility has been working towards building a
healthy biological environment over the last 2 years as flows have slowly increased and the system is more adequately
maintained.
Bob Barr informed the ARO of a landslide that had occurred on the site after he became aware of it on 7/19/22. The slide
resulted in damage to some of the 2-inch zone subheaders and drip zones. The zones affected were manually shut off when
the slide was identified. This area was inspected, and a plan for repairs was being evaluated during the inspection.
Facility staff have been continually adjusting operations due to several permit limit exceedances (TSS in November and
December 2021). Mr. Rummel stated that because of the low flows and cycling of the lift station, inputs to the WWTP were
very septic upon arrival into the facility. He indicated that DO levels were stabilizing from what was once 15 to now around 5
mg/L. He has also been successfully lowering settleability from 65% to an average of 55%. During the 2021 inspection, the
ORC had indicated that effluent is sometimes routed to the upset tank when there is minimal flow to the facility. Please note
that if flows are routed to the upset tank for an entire month, this should be recorded on the NDMR - otherwise it appears
that all flows are sent to the irrigation tank.
The flow meter was operable (last calibrated July 2022) but still not printing during the inspection but the ORC indicated Bear
Lake has one on order. The mixers were operable, and staff are continuing to clean UV bulbs once a week and replacing
bulbs once a year (last replaced 8/3/22). The turbidity meter was operable and last calibrated in July 2022. The microscreen
drum filters were inoperable and being bypassed at the time of the inspection – please inform the division when these filters
have been repaired. The recirculation alarm was inspected and operable.
RPB systems is maintaining diesel for the WWTP backup generator. Bear Lake is contracting Allan Dearth Sons to service
the lift station power. As a reminder, the permittee is required to send out biannual fats, oil, and grease educational material
to all system users. 15NCAC 02T.0403 can be referenced for the requirements of a collection system under 200,000 gallons
per day. Annual fats, oils and grease education is a requirement for private systems and it is recommended that the
permittee add additional prohibited items to these educational materials regarding personal hygiene products, flushable
wipes, etc.. An example pamphlet is attached to this inspection report.
The collection system is being monitored and maintained by RPB systems. A collection system map is available at the
WWTP and spare pumps are maintained onsite. There were no reported issues with the collection system. Lift station 3 was
inspected – telemetry was active, the visual alarm was working, but the audible alarm was not. Lift station inspection
records were reviewed, and the ORC indicated every lift station is checked weekly. The ARO recommends keeping a
consistent log of which lift station system components are checked and continue to document notes as repairs are made
and issues are identified.
The ARO was informed that ownership to the property had changed which will require the completion of an updated
Operational Agreement and Change of Ownership forms to be submitted.
Page 2 of 7
DocuSign Envelope ID: 5741B5DD-6121-4C8D-9B60-189AE800531F
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0029233
08/04/2022 Compliance Evaluation
Boto NC Properties LLC
Routine
Type Yes No NA NE
Infiltration System
Lagoon Spray, LR
Activated Sludge Spray, LR
Single Family Spray, LR
Activated Sludge Spray, HR
Activated Sludge Drip, LR
Single Family Drip
Recycle/Reuse
Reuse (Quality)
Treatment Yes No NA NE
Are Treatment facilities consistent with those outlined in the current permit?
Do all treatment units appear to be operational? (if no, note below.)
Yes, however low flows coming into the facility.Comment:
Treatment Influent Pump Station Yes No NA NE
Is the pump station free of bypass lines or structures?
Is the general housekeeping acceptable?
Are all pumps present?
Are all pumps operable?
Are floats/controls operable?
Are audio and visual alarms available?
Are audio and visual alarms operational?
# Are SCADA/Telemetry alarms required?
Are SCADA/Telemetry available?
Are SCADA/Telemetry operational?
Has auto-dialer. Bear Lake is maintaining a contract with a fuel vendor to supply the influent lift
station generator. See summary for details.
Comment:
Treatment Flow Measurement-Influent Yes No NA NE
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Comment:
Page 3 of 7
DocuSign Envelope ID: 5741B5DD-6121-4C8D-9B60-189AE800531F
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0029233
08/04/2022 Compliance Evaluation
Boto NC Properties LLC
Routine
Treatment Flow Measurement-Water Use Records Yes No NA NE
Is water use metered?
Are the daily average values properly calculated?
Comment:
Treatment Flow Measurement-Effluent Yes No NA NE
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
The flowmeter was operable and last calibrated in July 2022. The printer function was not
operable during the inspection, although the ORC indicated a new printer was on-order.
Comment:
Standby Power Yes No NA NE
Is automatically activated standby power available?
Is generator tested weekly by interrupting primary power source?
Is generator operable?
Does generator have adequate fuel?
Standby generators are servied by Allan Dearth Sons and backup fuel is supplied by Blossman
Gases.
Comment:
Treatment Barscreen Yes No NA NE
Is it free of excessive debris?
Is disposal of screenings in compliance?
Are the bars spaced properly?
Is the unit in good condition?
Facility has a small manual barscreen. Low flows entering during the time of the inspection.Comment:
Treatment Activated Sludge Yes No NA NE
Is the aeration mechanism operable?
Is the aeration basin thoroughly mixed?
Is the aeration equipment easily accessed?
Is Dissolved Oxygen adequate?
Are Settleometer results acceptable?
Is activated sludge an acceptable color?
Aeration basin in acceptable condition during inspection. ORC indicated the facility looks at
settleability once weekly and is typically at approximately 55%.
Comment:
Treatment Clarifiers Yes No NA NE
Are the weirs level?
Page 4 of 7
DocuSign Envelope ID: 5741B5DD-6121-4C8D-9B60-189AE800531F
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0029233
08/04/2022 Compliance Evaluation
Boto NC Properties LLC
Routine
Are the weirs free of solids and algae?
Is the scum removal system operational?
Is the scum removal system accessible?
Is the sludge blanket at an acceptable level?
Is the effluent from the clarifier free of excessive solids?
Comment:
Treatment Return pumps Yes No NA NE
Are they in place?
Are they operational?
Comment:
Treatment Filters Yes No NA NE
Is the filter media present?
Is the filter media the correct size and type?
Is the air scour operational?
Is the scouring acceptable?
Is the clear well free of excessive solids?
Is the mud well free of excessive solids and filter media?
Does backwashing frequency appear adequate?
Microscreen drum filter not operable during inspection and being bypassed.Comment:
Treatment Disinfection Yes No NA NE
Is the system working?
Do the fecal coliform results indicate proper disinfection?
Is there adequate detention time (>=30 minutes)?
Is the system properly maintained?
If gas, does the cylinder storage appear safe?
Is the fan in the chlorine feed room and storage area operable?
Is the chlorinator accessible?
If tablets, are tablets present?
Are the tablets the proper size and type?
Is contact chamber free of sludge, solids, and growth?
If UV, are extra UV bulbs available?
If UV, is the UV intensity adequate?
# Is it a dual feed system?
Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)?
If yes, then is there a Risk Management Plan on site?
Page 5 of 7
DocuSign Envelope ID: 5741B5DD-6121-4C8D-9B60-189AE800531F
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0029233
08/04/2022 Compliance Evaluation
Boto NC Properties LLC
Routine
If yes, then what is the EPA twelve digit ID Number? (1000-____-____)
If yes, then when was the RMP last updated?
UV bulbs are being cleaned weekly and replaced yearly (last replaced 8/3/22).Comment:
Record Keeping Yes No NA NE
Is a copy of current permit available?
Are monitoring reports present: NDMR?
NDAR?
Are flow rates less than of permitted flow?
Are flow rates less than of permitted flow?
Are application rates adhered to?
Is GW monitoring being conducted, if required (GW-59s submitted)?
Are all samples analyzed for all required parameters?
Are there any 2L GW quality violations?
Is GW-59A certification form completed for facility?
Is effluent sampled for same parameters as GW?
Do effluent concentrations exceed GW standards?
Are annual soil reports available?
# Are PAN records required?
# Did last soil report indicate a need for lime?
If so, has it been applied?
Are operational logs present?
Are lab sheets available for review?
Do lab sheets support data reported on NDMR?
Do lab sheets support data reported on GW-59s?
Are Operational and Maintenance records present?
Were Operational and Maintenance records complete?
Has permittee been free of public complaints in last 12 months?
Is a copy of the SOC readily available?
No treatment units bypassed since last inspection?
Checked operational logs for WWTP and lift stations. It is recommended that lift station
inspection logs provide more detail on components routinely inspected and maintenance
performed. Audio alarm not operable on lift station 3.
Comment:
End Use-Reuse Yes No NA NE
Is the acreage in the permit being utilized?
Does the acreage specified in the permit correspond to the measured acreage at the site?
Are all essential units provided in duplicate?
Page 6 of 7
DocuSign Envelope ID: 5741B5DD-6121-4C8D-9B60-189AE800531F
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0029233
08/04/2022 Compliance Evaluation
Boto NC Properties LLC
Routine
Is an automatically activated standby power source available?
Is the equalization capacity adequate?
Is aerated flow equalization present?
Has the turbidity meter been calibrated in the last 12 months?
Does the turbidity meter have recording capabilities?
Is all flow diverted at the appropriate times?
Is all upset wastewater diverted from reuse storage unit?
Is all upset wastewater treated, retreated, or disposed of acceptably?
Is upset wastewater treated prior to discharge to irrigation storage?
Is public access restricted from irrigation area during active site use?
If golf course, is a sign posted in plain sight on the club house?
Is the cover crop acceptable?
Are buffers adequate?
Is the site free of ponding/runoff?
Is the acreage in the permit being utilized?
Is the application equipment acceptable?
Is the application area free of limiting slopes?
How close is the closest water supply well?
Are any supply wells within the CB?
Are any supply wells within 250' of the CB?
Is municipal water available in the area?
Are GW monitoring wells required?
Are GW monitoring wells located properly w/ respect to RB and CB?
Are GW monitoring wells properly constructed, including screened interval?
Facility drip irrigates to a pine forest. Not all upset water can be routed to the upset tank
because fecal results are not instantaneous. A landslide had occured prior to the inspection
and destroyed some of the 2-inch zone subheaders and drip zones. This area was in the
process of being assessed for repair during the inspection. Turbidity meter last calibrated July
2022.
Comment:
Page 7 of 7
DocuSign Envelope ID: 5741B5DD-6121-4C8D-9B60-189AE800531F
DON'T
SINK IT!!
DON'T
SINK IT!!
DON'T
FLUSH IT!!
DON'T
FLUSH IT!!
No GreaseNo Grease
Fats
Butter
Wax
Cheese
Heavy Cream
Fats
Butter
Wax
Cheese
Heavy Cream
No Plastics / LatexNo Plastics / Latex
Wrappers
Femine Product Covers
Lids / Liners / Rings
Condoms
Bandaids
Wrappers
Femine Product Covers
Lids / Liners / Rings
Condoms
Bandaids
No Paper / MaterialsNo Paper / Materials
(Other Than Toilet Tissue)
Baby Wipes / Flushable Wipes
Paper Towels / Towlettes
Facials Tissues
Napkins
Guaze
Dental Floss
Matches
Feminine Products / Paper Covers
(Other Than Toilet Tissue)
Baby Wipes / Flushable Wipes
Paper Towels / Towlettes
Facials Tissues
Napkins
Guaze
Dental Floss
Matches
Feminine Products / Paper Covers
Other No FlushOther No Flush
Your Local Public Utility:Your Local Public Utility:
All Medicines / Cigarettes
Coffee Grounds / Left Over FoodHair Clippings
Kitty Litter / Pet Wastes
Grease / Oils / Solvents
All Medicines / Cigarettes
Coffee Grounds / Left Over FoodHair Clippings
Kitty Litter / Pet Wastes
Grease / Oils / Solvents
No Liquid WasteNo Liquid Waste
Pesticides
Household Chemicals
Paints
Paint Thinners
Solvents (e.g. hobbies)
Oils
Pesticides
Household Chemicals
Paints
Paint ThinnersSolvents (e.g. hobbies)
Oils
Other No's For The SinkOther No's For The Sink
Coffee Grounds
Food Waste
Coffee Grounds
Food Waste
Provided by The Department of Environmental Assistance and Customer Service, and N.C. DENR!NO HECHE
EN EL
FREGADERO!!NO HECHE
EN EL
FREGADERO!!NO BOTE
EN EL
INODORO!!NO BOTE
EN EL
INODORO!
Materiales GrasosMateriales Grasos
Grasa
Manteca
Cera
Queso
Cremas Espesas
Grasa
Manteca
Cera
Queso
Cremas Espesas
Embalajes
Envolturas de Articulos Femeninos
Protectores / Revestimientos / Anillos Protectores
Condones
Curitas
Embalajes
Envolturas de Articulos Femeninos
Protectores / Revestimientos / Anillos Protectores
Condones
Curitas
Materiales de PapelMateriales de Papel
(Excepto Papel Higiénico)
Toallas de Papel / Toallitas Húmedas
Pañuelos Desechables
Toallitas Desechables
Servilletas
Gasa
Hilo Dental
Fósforos
Productos Femenimos y Envases de Papel
(Excepto Papel Higiénico)
Toallas de Papel / Toallitas Húmedas
Pañuelos Desechables
Toallitas Desechables
Servilletas
Gasa
Hilo Dental
Fósforos
Productos Femenimos y Envases de Papel
Ni Tampoco DesecheNi Tampoco Deseche
Medicamentos / Cigarrillos
Granos de Café / Sobras de ComidaCabello o Pelo de Animales
Arena para Gatos / Excrementos de Mascotas
Grasa / Aceites / Disoventes
Medicamentos / Cigarrillos
Granos de Café / Sobras de ComidaCabello o Pelo de Animales
Arena para Gatos / Excrementos de Mascotas
Grasa / Aceites / Disoventes
PesticidasQuímicos para el Hogar
Pinturas
Diluyente de PinturasDisolventes
Aceites
PesticidasQuímicos para el Hogar
Pinturas
Diluyente de PinturasDisolventes
Aceites
Ni Tampoco Desheche en el FregaderoNi Tampoco Desheche en el Fregadero
Granos de Café
Cantidad Excesiva de Desperdicios de Comida
Granos de Café
Cantidad Excesiva de Desperdicios de Comida
Residuos LiquidosResiduos Liquidos
Plastico / LatexPlastico / Latex
Su Utilidad Publica Local:Su Utilidad Publica Local:Proporcionada por el Departamento de Asistencia Ambiental y Servicio al Cliente, y N.C. DENRDocuSign Envelope ID: 5741B5DD-6121-4C8D-9B60-189AE800531F