Loading...
HomeMy WebLinkAboutNCG080893_2022 DMR_20220615NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG080000 Transit and Transportation Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG08 0893 Person Collecting Samples: Lorien Deaton Facility Name: Greensboro Transit Authority Laboratory Name: Pace Analytical Facility County: Guilford Laboratory Cert. No.: 12 Discharge during this period: ✓CYes ®No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Yes ©✓ No If so, which Tier (I, II, or III)? A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR E]Yes ® No Date Uploaded: 06/15/2022 Analytical Monitoring Requirements for Vehicle & Equipment Maintenance Areas — Benchmarks in (Red) Parameter Code Parameter Outfall001 Outfall002 Outfall003 Outfall004 Outfall N/A Receiving Stream Class South Buffalo Creek South Buffalo Creek South Buffalo Creek South Buffalo Creek N/A Date Sample Collected MM/DD/YYYY 06/08/2022 06/08/2022 06/08/2022 06/08/2022 46529 24-Hour Rainfall in inches 0.17 0.17 0.17 0.17 C0530 TSS in mg/L (100 or 50*) 16.5 19.3 6.1 9.1 00552 Non -Polar Oil & Grease in mg/L (15) ND NO NO ND 00400 pH in standard units (6.0-9.0 FW, 6.8 — 8.5 SW) 7.2 6.8 8.2 8.1 Estimated New Motor/Hydraulic Oil NCOIL Usage in gal/month 350 350 350 350 Outfalls to outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." ature of Permittee or Delegated Authorized Individual lorien.deaton@greensboro-nc.gov Email Address 06/15/2022 Date 336-209-8934 Phone Number aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 June 15, 2022 Richard P Lovett City of Greensboro Field Operations Department 401 Patton Ave Greensboro, NC 27406 RE: Project: GREENSBORO TRANSIT AUTHORITY Pace Project No.: 92609151 Dear Richard Lovett: Enclosed are the analytical results for sample(s) received by the laboratory on June 09, 2022. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services -Asheville • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Tyriek Hooks tyriek.hooks@pacelabs.com (704)875-9092 Project Manager Enclosures cc: Lorien Deaton, City of Greensboro Field Operations Department REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 13 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: GREENSBORO TRANSIT AUTHORITY Pace Project No.: 92609151 Pace Analytical Services Charlotte South Carolina Laboratory ID: 99006 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Laboratory ID: 99006 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 North Carolina Drinking Water Certification #: 37712 North Carolina Wastewater Certification #: 40 CERTIFICATIONS South Carolina Certification #: 99006001 South Carolina Drinking Water Cert. #: 99006003 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Louisiana DoH Drinking Water#: LA029 Virginia/VELAP Certification #: 460221 South Carolina Laboratory ID: 99030 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 13 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 SAMPLE ANALYTE COUNT Project: Pace Project No.: GREENSBORO TRANSIT AUTHORITY 92609151 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92609151001 OUTFALL SDO-001 EPA 1664B REL 1 PASI-C SM 254OD-2015 ZMC 1 PASI-A 92609151002 OUTFALL SDO-002 EPA 1664B REL 1 PASI-C SM 254OD-2015 ZMC 1 PASI-A 92609151003 OUTFALL SDO-003 EPA 1664B REL 1 PASI-C SM 254OD-2015 ZMC 1 PASI-A 92609151004 OUTFALL SDO-004 EPA 1664B REL 1 PASI-C SM 254OD-2015 ZMC 1 PASI-A PASI-A = Pace Analytical Services - Asheville PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 13 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: GREENSBORO TRANSIT AUTHORITY Pace Project No.: 92609151 Sample: OUTFALL SDO-001 Lab ID: 92609151001 Collected: 06/08/22 16:17 Received: 06/09/22 09:37 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Oil and Grease ND mg/L 4.8 1 06/14/22 01:45 2540D Total Suspended Solids Analytical Method: SM 2540D-2015 Pace Analytical Services - Asheville Total Suspended Solids 16.5 mg/L 2.5 1 06/13/22 15:11 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 06/15/2022 07:44 AM without the written consent of Pace Analytical Services, LLC. Page 4 of 13 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: GREENSBORO TRANSIT AUTHORITY Pace Project No.: 92609151 Sample: OUTFALL SDO-002 Lab ID: 92609151002 Collected: 06/08/22 16:14 Received: 06/09/22 09:37 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Oil and Grease ND mg/L 4.9 1 06/14/22 01:45 2540D Total Suspended Solids Analytical Method: SM 2540D-2015 Pace Analytical Services - Asheville Total Suspended Solids 19.3 mg/L 2.5 1 06/13/22 15:12 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 06/15/2022 07:44 AM without the written consent of Pace Analytical Services, LLC. Page 5 of 13 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: GREENSBORO TRANSIT AUTHORITY Pace Project No.: 92609151 Sample: OUTFALL SDO-003 Lab ID: 92609151003 Collected: 06/08/22 16:09 Received: 06/09/22 09:37 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Oil and Grease ND mg/L 4.9 1 06/14/22 01:45 2540D Total Suspended Solids Analytical Method: SM 2540D-2015 Pace Analytical Services - Asheville Total Suspended Solids 6.1 mg/L 2.5 1 06/13/22 15:12 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 06/15/2022 07:44 AM without the written consent of Pace Analytical Services, LLC. Page 6 of 13 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: GREENSBORO TRANSIT AUTHORITY Pace Project No.: 92609151 Sample: OUTFALL SDO-004 Lab ID: 92609151004 Collected: 06/08/22 16:04 Received: 06/09/22 09:37 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Oil and Grease ND mg/L 4.9 1 06/14/22 01:45 2540D Total Suspended Solids Analytical Method: SM 2540D-2015 Pace Analytical Services - Asheville Total Suspended Solids 9.1 mg/L 2.5 1 06/13/22 15:12 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 06/15/2022 07:44 AM without the written consent of Pace Analytical Services, LLC. Page 7 of 13 Pace Analytical Services, LLC aceArraiytical ® 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 www.pacelabs.com (704)875-9092 QUALITY CONTROL DATA Project: GREENSBORO TRANSIT AUTHORITY Pace Project No.: 92609151 QC Batch: 703866 Analysis Method: EPA 1664B QC Batch Method: EPA 1664B Analysis Description: 1664 HEM, Oil and Grease Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92609151001, 92609151002, 92609151003, 92609151004 METHOD BLANK: 3673265 Matrix: Water Associated Lab Samples: 92609151001, 92609151002, 92609151003, 92609151004 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Oil and Grease mg/L ND 5.0 06/14/22 01:45 LABORATORY CONTROL SAMPLE: 3673266 Spike LCS LCS % Rec Parameter Units Cone. Result % Rec Limits Qualifiers Oil and Grease mg/L 40 36.8 92 78-114 MATRIX SPIKE SAMPLE: Parameter 3673267 Units 92609129002 Result Spike MS MS % Rec Cone. Result % Rec Limits Qualifiers Oil and Grease mg/L 10.6 39.2 41.8 80 78-114 SAMPLE DUPLICATE: 3673268 92609136001 Dup Parameter Units Result Result RPD Qualifiers Oil and Grease mg/L ND ND Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 06/15/2022 07:44 AM without the written consent of Pace Analytical Services, LLC. Page 8 of 13 Pace Analytical Services, LLC aceArraiytical ® 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 www.pacelabs.com (704)875-9092 QUALITY CONTROL DATA Project: GREENSBORO TRANSIT AUTHORITY Pace Project No.: 92609151 QC Batch: 704035 Analysis Method: SM 2540D-2015 QC Batch Method: SM 254OD-2015 Analysis Description: 2540D Total Suspended Solids Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92609151001, 92609151002, 92609151003, 92609151004 METHOD BLANK: 3673913 Matrix: Water Associated Lab Samples: 92609151001, 92609151002, 92609151003, 92609151004 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Suspended Solids mg/L ND 2.5 06/13/22 15:09 LABORATORY CONTROL SAMPLE: 3673914 Spike 1-CS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Suspended Solids mg/L 250 250 100 90-110 SAMPLE DUPLICATE: 3673915 92608832001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 2.6 35.5 173 D6 SAMPLE DUPLICATE: 3674245 92609136001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 16200 15400 5 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 06/15/2022 07:44 AM without the written consent of Pace Analytical Services, LLC. Page 9 of 13 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALIFIERS Project: GREENSBORO TRANSIT AUTHORITY Pace Project No.: 92609151 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis ofAcrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS D6 The precision between the sample and sample duplicate exceeded laboratory control limits. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 06/15/2022 07:44 AM without the written consent of Pace Analytical Services, LLC. Page 10 of 13 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: GREENSBORO TRANSIT AUTHORITY Pace Project No.: 92609151 Lab ID Sample ID QC Batch Method QC Batch 92609151001 OUTFALL SDO-001 EPA 1664B 703866 92609151002 OUTFALL SDO-002 EPA 1664B 703866 92609151003 OUTFALL SDO-003 EPA 1664B 703866 92609151004 OUTFALL SDO-004 EPA 1664B 703866 92609151001 OUTFALL SDO-001 SM 254OD-2015 704035 92609151002 OUTFALL SDO-002 SM 254OD-2015 704035 92609151003 OUTFALL SDO-003 SM 254OD-2015 704035 92609151004 OUTFALL SDO-004 SM 254OD-2015 704035 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 06/15/2022 07:44 AM without the written consent of Pace Analytical Services, LLC. Analytical Analytical Method Batch Page 11 of 13 a> to V *1 r',_ __ F s r t:,"�1 F' =�'s3 Cass S6' Y'F"i3 v 7 - Cl l a F! T U ✓ 'c .11l f 5 1i L 5_ l � a .: � i Fa �L''` EE E cr v d Cno w w w N r r M t; a o � rn V rn 114 V , P sd 4, a Iti ro u m u a o� u yr E r 4rlr y'UNr�.l�Mu V N ro w q U s Ft N Z-dl !- WrU U V U G.ra m a ;: W � o, •e o -w u 6 v to m ro ro u m U U:cs w •o [H a sr-.'C d Y M 'w N o-'o, m rt r r4co +1 r+ sr.-..p ❑ t - l F O is-+� -i 41 14 U-t.�Qy. AJ �:•1 N d N W 'fj a rt 10, a..y„ Y C u LQ Ca �m _ z (Y) o x s v M � Yif1r_r=r_ } mlus ll y� 'SE yr y ui , fJ a m x ka r,. C n�.o ❑ m a: E 1 X� V sp Jr� r E asEaa`3 v I?O x x x IL J n. w o � m Z vG v tu u 0 1 vw } U E a 3 Z �- Q ° Z v m Z a Z d a ❑ - a. n nti E E rye C N O U m v r'Y v w _'.F ' Ou.:- - O N m y C as �u c y u vu 3L y u U v R C Fu �. a Co Mr �a n `� E O C a> a o .� v> o E N m\ m a m o y y E }y }3 E m a u ❑ u ac a u F U u o❑ E �{ u a ` u o`/o rr rs U; -1 r U m a _ u o `° ♦ ► m; ' .: u' a �' to N z CD w " �° o LL ai ❑o ❑mv d 007 N Q t O r Q ' L i a ❑cu �li a � $ 0 d E o R C^4 a d d zt o o CL a D C cza C�:) O R' `, Z 0 m o C O O O Q , U O c r .. m / i u �����llJJll V ¢ C O U O o O N y o° a E ❑❑❑ E 1 n mg coa c' v ° v[ rrt za U b o w x r d r y o :J aj V .� c `a o as o rU. O .- a O a E c m o $ = o c qace uc#_Title: ENV-FRM-HUN1-0083 v01 Sample Condition Upon Receipt Effective Date: 05/121202205/12/2022 *Check mark top half of box if pH and/or dechlorination is verified and Project h WO# : 92609151 within the acceptance range for preservation samples. PM: TIH Due Date: 06/ 16/22 Exceptions: VOA, Coliform, TOC, Oil and Grease, DRO/8015 (waterl DOC, LLfig CLIENT: 92—Ci tyef GSO "Bottom half of box is to list number of bottles ***Check all unpreserved Nitrates for chlorine u " u a # E 3 V m a c c A aJ E '^� ri v m 4! v w a c iv E kn N M LII 3 ar a a cUl m E o V1 N m a ? 'p 71 t' v c V Mii. = ri ._+ m u N V 2 4 o 0 NM a E N ri V1 v m r� v a O w a E Z m m o Z atll-. m a Z a E N ri iV v m ervw A n O ro z a E 'n N N m v m `0 N v d v v � 5 W a 'O ai 2 v m E a H 7 " Q N v Q U x E ¢ =' r-1 2 r1 l7 Q a N v m Q ¢ E 0 N : M O d V x n O N = E a °' ri ." i C7 d V I a O N = 4 o Ln N V1 M l7 Q = z a i z Q J o J) N V rn i7 fl < O - E Op 1 S O1 lR Q O ry ry O ? E p a ? Z v m a a - E OH 7 O1 z a T O - E 6 V Q� o a = p a m O Z 0 l7 a v T V Y 7 ? iu J E vt N F- vl ? CL a J E o N H san `* �O z m E C1 N K m a s? c E .Q.1 E O 0 7 d ti c VI E O V1 z iv a a a Q J E V p 1 2 3 4 5 6 7 8 9 10 11 12 PH Adjustment Log for Preserved Samples Sample !D Type of Preservative pH upon receipt Date preservation adjusted Time preservation Amount of Preservative Lot N adjusted added Note:" WhObVOr there is a discrepancy affecting North Carolina compliance Samples, a Copy of this form will be sent to the North Carolina DENR Certification Office (i,e. Out of hold, incorrect preservative, out of temp, incorrect containers. Quallrax !D: 69614 Page 2 of 2 Page 13 of 13 K!`r��-F- Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit https:Hdeq.nc.gov/about/divisions/energy-mineral-land-resources/ npdes-stormwater-gps Permit No.: N/C/ / / / / / / / or Certificate of Coverage No.: N/C/G/ 0 / 8 / 0 /, 8 / 9 / 3 Facility Name: Greensboro Transit Authority (GTA) County: Guilford Phone No. 336-209-8934 Inspector: Lorien Deaton Date of Inspection: 06/08/2022 Time of Inspection: 1617 Total Event Precipitation (inches): 0.17 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signature of Permittee or Designee) 1. Outfall Description: Outfall No. 001 Structure (pipe, ditch, etc.): Receiving Stream: South Buffalo Creek Describe the industrial activities that occur within the outfall drainage area: Vehicle maintenance, bus parking, and employee parking. Pagel of 2 SWU-242, Last modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: Clear 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): None 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 ® 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: O 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 7. 8. 9. �1 2 3 4 5 Is there any foam in the stormwater discharge? O Yes �S5 No. Is there an oil sheen in the stormwater discharge? oYes ?0 No. Is there evidence of erosion or deposition at the outfall? o Yes P No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 06/01/2018 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit https:Hdeq.nc.gov/about/divisions/energy-mineral-land-resources/ npdes-stormwater-gps Permit No.: N/C/ / / / / / / / or Certificate of Coverage No.: N/C/G/ 0 / 8 /, 0 /. 0 /. 0 / 0 / Facility Name: Greensboro Transit Authority (GTA) County: Guilford Phone No. 336-209-8934 Inspector: Lorien Deaton Date of Inspection: 06/08/2022 Time of Inspection: 1614 Total Event Precipitation (inches): 0.17 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: of Permittee or Designee) 1. Outfall Description: Outfall No. 002 Structure (pipe, ditch, etc.): pipe Receiving Stream: Smith Buffalo Creek Describe the industrial activities that occur within the outfall drainage area: Vehicle maintenance, bus parking, and employee parking. Page 1 of 2 SWU-242, Last modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: Clear 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): None 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: C) 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 10 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: Ql 2 3 4 5 7. 8. 9. Is there any foam in the stormwater discharge? o Yes 0 No. Is there an oil sheen in the stormwater discharge? oYes �Q No. Is there evidence of erosion or deposition at the outfall? o Yes O� No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 06/01/2018 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit https:Hdeq.nc.gov/about/divisions/energy-mineral-land-resources/ npdes-stormwater-gps Permit No.: N/C/ / / / / / / / or Certificate of Coverage No.: N/C/G/ 0 / 8 / 0 / 0 / 0 /. 0 / Facility Name: Greensboro Transit Authority (GTA) County: Guilford Phone No. Inspector: Lorien Deaton Date of Inspection: Time of Inspection: Total Event Precipitation (inches): 0.17 336-209-8934 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signature of Permittee or Designee) 1. Outfall Description: Outfall No. 003 Structure (pipe, ditch, etc.): nine Receiving Stream: South Buffalo Creek Describe the industrial activities that occur within the outfall drainage area: Vehicle maintenance, bus narking, and employee parking. Page 1 of 2 SWU-242, Last modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: Clear 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): None 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: (l 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 7. 8. 9. 10 2 3 4 5 Is there any foam in the stormwater discharge? o Yes No. Is there an oil sheen in the stormwater discharge? 0Yes }Q No. Is there evidence of erosion or deposition at the outfall? O Yes (X No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 06/01/2018 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit https:Hdeq.nc.gov/about/divisions/energy-mineral-land-resources/ npdes-stormwater-gps Permit No.: N/C/ / / / / / / / or Certificate of Coverage No.: N/C/G/ 0 / 8 / 0 /. 0 / 0 /. 0 / Facility Name: Greensboro Transit Authors (GTA) County: Guilford Phone No. 336-209-8934 Inspector: Lorien Deaton Date of Inspection: 06/08/2022 Time of Inspection: 1604 Total Event Precipitation (inches): 0.17 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signature of Permittee or Designee) 1. Outfall Description: Outfall No. 004 Structure (pipe, ditch, etc.): Receiving Stream: South Buffalo Creek Describe the industrial activities that occur within the outfall drainage area: Vehicle maintenance, bus narking, and employee parking. Page 1 of 2 SWU-242, Last modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: Clear 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy: �l 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: O 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 0 2 3 4 5 7. Is there any foam in the stormwater discharge? O Yes No. 8. Is there an oil sheen in the stormwater discharge? OYes No. 9. Is there evidence of erosion or deposition at the outfall? O Yes P No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 06/01/2018 6/9/22, 8:17 AM USGS Current Conditions for USGS 02094770 SOUTH BUFFALO CREEK AT US 220 AT GREENSBORO, NC .USGS Hok.-= Contact USGS Search USGS National Water Information System: Web Interface USGS Water Resources Surface Water v North Carolina v GO Click to hideNews Bulletins • Explore the NEW USGS National Water Dashboard interactive map to access real- time water data from over 13,500 stations nationwide. • Full News Click to hide state -specific text • USGS Water Resources of the South Atlantic Water Science Center: the place to start for all USGS water information in the SAWSC. • Real-time data Streamflow I I Water -Quality I I Groundwater Levels Precipitation • Statewide Rainfall Map • Live Streaming RiverCams • StreamStats - online tool for basin and flow characteristics • USGS Flood Event Viewer • Sign up for custom Water Alerts by text or email Questions about data? Click here. USGS 02094770 SOUTH BUFFALO CREEK AT US 220 AT GREENSBORO, NC PROVISIONAL DATA SUBJECT TO REVISION Available data for this site Time -series: Daily data GO Click to hidestation-specific text This station is operated in cooperation with the City of Greensboro, North Carolina. 4.REE�lS94RA This station managed by the South Atlantic WSC Raleigh Field Office. Available Parameters Period of Record All 3 Available Parameters for this site https://waterdata.usgs.gov/nc/nwis/dv?cb_00045=on&format=htmI&site_no=02094770&referred_module=sw&period=&begin_date=2022-06-08&end_... 1 /3 6/9/22, 8:17 AM USGS Current Conditions for USGS 02094770 SOUTH BUFFALO CREEK AT US 220 AT GREENSBORO, NC Available Parameters Period of Record 00045 Precipitation(Sum) 1999-09-30 2022-06-08 ❑ 00060 Discharge(Max.,Min.,Mean) 1998-08-01 2022-06-08 ❑ 00065 Gage height(Max.,Min.,Mean) 1998-07-21 2022-06-08 Output format O Graph O Graph w/ stats O Graph w/ meas O Graph w/ (up to 3) parms O Table O Tab -separated Days (0) Summary of all available data for this site Instantaneous -data availability statement -- or -- Begin date 2022-06-08 End date 2022-06-08 Daily Sum Precipitation, total. inches DATE Jun 2022 EKIEEI 00 COUNT �1 MAX 0.17 MIN 0.17 Explanation EEP—rovisional data subject to revision. Questions about sites/data? Feedback on this web site Automated retrievals Help Data Tips Explanation of terms Subscribe for system changes News Arraccihility Fr)TA Privary Pnlirinc anri Notices U.S. Department of the Interior I U.S. Geological Survey_ Title: USGS Surface -Water Daily Data for North Carolina URL: https://waterdata.usgs.gov/nc/nwis/dv? GO Page Contact Information: North Carolina Water Data Support Team https://wate rdata. usgs. gov/nc/nwis/dv?cb_00045=on&fo rmat=htmI&site_no=02094770& refe rred_mod uIe=sw& pe riod=&beg in_date=2022-06-08&end_... 2/3