Loading...
HomeMy WebLinkAbout20221091 Ver 1_ePCN Application_20220812Pre -Construction Notification (PCN) Form For Nationwide Permits and Regional General Permits (along with corresponding Water Quality Certifications) April 13, 2022 Ver 4.3 Initial Review Has this project met the requirements for acceptance in to the review process?* OO Yes O No Is this project a public transportation project?* OYes 0No Change only if needed. Pre -Filing Meeting Date Request was submitted on: 7/12/2022 BIMS # Assigned * 20221091 Is a payment required for this project?* 0 No payment required O Fee received O Fee needed - send electronic notification Reviewing Office* Fayetteville Regional Office - (910) 433-3300 Information for Initial Review Version#* What amout is owed?* O $240.00 O $570.00 Select Project Reviewer* Chad Turlington:eads\ccturlington la. Name of project: Blue Panther Communication Facility la. Who is the Primary Contact?* Greg McKee lb. Primary Contact Email:* gmckee@ebiconsulting.com Date Submitted 8/12/2022 Nearest Body of Water South River Basin Cape Fear Water Classification C Site Coordinates Latitude: 34.674046 A. Processing Information Longitude: -78.355222 lc. Primary Contact Phone:* (717)903-5399 County (or Counties) where the project is located: Bladen Is this a NCDMS Project 0Yes ONo Is this project a public transportation project?* 0Yes ONo la. Type(s) of approval sought from the Corps: Section 404 Permit (wetlands, streams and waters, Clean Water Act) Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act) Has this PCN previously been submitted?* Yes No 1 b. What type(s) of permit(s) do you wish to seek authorization? Nationwide Permit (NWP) Regional General Permit (RGP) Standard (IP) lc. Has the NWP or GP number been verified by the Corps? Yes No Nationwide Permit (NWP) Number: 57 - Electric Utility Line and Telecommunications Activities — (frequently used) NWP Numbers (for multiple NWPS): ld. Type(s) of approval sought from the DWR: 401 Water Quality Certification - Regular Non-404 Jurisdictional General Permit Individual 401 Water Quality Certification le. Is this notification solely for the record because written approval is not required? For the record only for DWR 401 Certification: For the record only for Corps Permit: 1f. Is this an after -the -fact permit application?* Yes No lg. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? Yes No lg. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? Yes No 1 h. Is the project located in any of NC's twenty coastal counties? Yes No 1j. Is the project located in a designated trout watershed? Yes No B. Applicant Information ld. Who is applying for the permit? Owner Applicant (other than owner) le. Is there an Agent/Consultant for this project?* Yes No 2. Owner Information 2a. Name(s) on recorded deed: Bessie L Watts 2b. Deed book and page no.: 0047311 2c. Contact Person: 2d. Address Street Address 44 South Munn Ave Address Line 2 Apt 3R City East Orange Postal /Zip Code 07018 401 Water Quality Certification - Express Riparian Buffer Authorization State / Province / Region NJ Country USA Yes No Yes No 2e. Telephone Number: (717)903-5399 2g. Email Address:* bleewatts@comcast. net 2a. Name(s) on recorded deed: Claretha Lee 2b. Deed book and page no.: 0047311 2c. Contact Person: 2d. Address Street Address 701 Marble Court Address Line 2 City Fayetteville Postal / Zip Code 28311 2e. Telephone Number: (678)488-1866 2g. Email Address:* mgrugan@verticalbridge.com 3. Applicant Information (if different from owner) 3a. Name: Matthew Grugan 3b. Business Name: Vertical Bridge Development LLC 3c. Address Street Address 750 Park of Commerce Drive, Suite 200 Address Line 2 City Boca Raton Postal / Zip Code 33487 3d. Telephone Number: (678)488-1866 3f. Email Address:* mgrugan@verticalbddge.com 4. Agent/Consultant (if applicable) 4a. Name: Kara Giblin 4b. Business Name: SWCA Environmental Consultants 4c. Address Street Address 113 Edinburgh South Drive, Suite 120 Address Line 2 City Cary Postal / Zip Code 27511 4d. Telephone Number: (919)292-2200 4f. Email Address:* kgiblin@swca.com 2f. Fax Number: State I Province / Region NC Country USA 2f. Fax Number: State / Province / Region FL Country USA 3e. Fax Number: State / Province / Region NC Country United States 4e. Fax Number: C. Project Information and Prior Project History 1. Project Information lb. Subdivision name: (if appropriate) lc. Nearest municipality / town: Elizabethtown 2. Project Identification 2a. Property Identification Number: 139300363641, 139300472048 2c. Project Address Street Address 6676 Hwy 210 Address Line 2 City Elizabethtown Postal / Zip Code 28337 3. Surface Waters 3a. Name of the nearest body of water to proposed project: * South River 3b. Water Resources Classification of nearest receiving water: * C 3c. What river basin(s) is your project located in?* Cape Fear 3d. Please provide the 12-digit HUC in which the project is located. 030300060208 4. Project Description and History 2b. Property size: 1.2 State / Province / Region NC Country United States 4a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: * The communication tower site would be located within parcel 139300472041, which is undeveloped with upland forest and forested wetlands Access will be via an existing two -track road within parcel 139300472048 which will be improved. The surrounding area is rural residential. 4b. Have Corps permits or DWR certifications been obtained for this project (including all prior phases) in the past?* ® Yes 0 No O Unknown If yes, please give the DWR Certification number or the Corps Action ID (exp. SAW-0000-00000). PJD signed 5/6/2022 (SAW-2022-00534) is attached. 4f. List the total estimated acreage of all existing wetlands on the property: 0.2 4g. List the total estimated linear feet of all existing streams on the property: 52 4h. Explain the purpose of the proposed project:* The purpose is to install a new 300' guyed communications tower. 4i. Describe the overall project in detail, including indirect impacts and the type of equipment to be used: * The project area is approximately 1.2 acres including the area for the cell tower and the access road. The area will be cleared and graded to develop a pad for the tower. The existing two - track road will be improved to provide access. Standard construction equipment will be used. Construction sequence and erosion control are detailed on the attached engineering drawings. Impacts to wetlands will occur at three access road crossings; a culvert will be installed at the stream crossing. The tower was sited to avoid wetlands. 5. Jurisdictional Determinations 5a. Have the wetlands or streams been delineated on the property or proposed impact areas? * • Yes 0 Unknown Comments: 5b. If the Corps made a jurisdictional determination, what type of determination was made? * O Preliminary 0 Approved 0 Not Verified 0 Unknown 0 N/A Corps AID Number: SAW-2022-00534 5c. If 5a is yes, who delineated the jurisdictional areas? Name (if known): Agency/Consultant Company: Other: Mark Mickley, Paul Bright SWCA Environmental Consultants 5d. List the dates of the Corp jurisdiction determination or State determination if a determination was made by the Corps or DWR PJD signed 5/6/2022 (SAW-2022-00534) is attached. 6. Future Project Plans 6a. Is this a phased project?* Yes O No Are any other NWP(s), regional general permit(s), or individual permits(s) used, or intended to be used, to authorize any part of the proposed project or related activity? No D. Proposed Impacts Inventory 1. Impacts Summary 1a. Where are the impacts associated with your project? (check all that apply): Cl Wetlands cal Streams -tributaries O Open Waters DI Pond Construction 2. Wetland Impacts O Buffers 2a. Site #* (?) 2a1 Reason (?) 2b. Impact type* (?) 2c. Type of W.* 2d. W. name 2e. Forested* 2f. Type of Jurisdicition* (?) 2g. Impact area* 1 Access Road P Bottomland Hardwood Forest WA Yes Corps 0.102 (acres) 2 Tower Anchor P Bottomland Hardwood Forest WA Yes Corps 0.009 (acres) 3 Access Road P Bottomland Hardwood Forest WB Yes Corps 0.039 (acres) 4 Access Road P Bottomland Hardwood Forest WB Yes Corps 0.029 (acres) 2g. Total Temporary Wetland Impact 0.000 2g. Total Wetland Impact 0.179 2g. Total Permanent Wetland Impact 0.179 21. Comments: Impacts from access road and anchors. Tower pad sited to avoid wetlands. See attached plans Sheet C8 - C8.2 (pdf pgs. 12-14) 3. Stream Impacts 3a. Reason for impact (?) 3b.lmpact type* 3c. Type of impact* 3d. S. name* 3e. Stream Type* (?) 3f. Type of Jurisdiction* 3g. S. width 3h. Impact length* S1 Access Road Permanent Culvert SA Intermittent Corps 3 Average (feet) 52 (linear tee() 31. Total jurisdictional ditch impact in square feet: 0 31. Total permanent stream impacts: 52 31. Total stream and ditch impacts: 52 3j. Comments: Culvert for new access road. See attached plans Sheet C8 - C8.2 (pdf pgs. 12-14) E. Impact Justification and Mitigation 31. Total temporary stream impacts: 0 1. Avoidance and Minimization la. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project: The communication tower location was adjusted to avoid and minimize impacts. Most wetlands and streams on the property will remain undisturbed. 1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques: During construction the wetland boundaries will be clearly delineated and signage will be placed to indicate 'No Impact Allowed Past This Point'. Erosion control are detailed on the engineering drawings. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? • Yes No 2c. If yes, mitigation is required by (check all that apply): DWR Corps 2d. If yes, which mitigation option(s) will be used for this project? Mitigation bank O Payment to in -lieu fee program Permittee Responsible Mitigation F. Stormwater Management and Diffuse Flow Plan (required by DWR) 1. Diffuse Flow Plan 1 a. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules? Yes • No If no, explain why: Project is in the Cape Fear basin where rules do not apply. 2. Stormwater Management Plan 2a. Is this a NCDOT project subject to compliance with NCDOT's Individual NPDES permit NCS000250?* 0Yes ®No 2b. Does this project meet the requirements for low density projects as defined in 15A NCAC 02H .1003(2)? • Yes No Comments: Erosion control plan, including silt fence, in attached engineering drawings (C8-C9). G. Supplementary Information 1. Environmental Documentation la. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land?* Yes • No 2. Violations (DWR Requirement) 2a. Is the site in violation of DWR Water Quality Certification Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), or DWR Surface Water or Wetland Standards or Riparian Buffer Rules (15A NCAC 2B .0200)?* Yes • No 3. Cumulative Impacts (DWR Requirement) 3a. Will this project result in additional development, which could impact nearby downstream water quality?* Yes • No 3b. If you answered "no," provide a short narrative description. There are no anticipated future developments resulting from the communication tower project. 4. Sewage Disposal (DWR Requirement) 4a. Is sewage disposal required by DWR for this project?* Yes ® No 0 N/A 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or habitat?* Yes • No 5b. Have you checked with the USFWS concerning Endangered Species Act impacts?* O Yes O No 5d. Is another Federal agency involved?* 0 Yes 5e. Is this a DOT project located within Division's 1-8? 0Yes CNo O• No O Unknown 5f. Will you cut any trees in order to conduct the work in waters of the U.S.? OYes 0No 5g. Does this project involve bridge maintenance or removal? 0Yes ®No 5h. Does this project involve the construction/installation of a wind turbine(s)?* 0 Yes ® No 5i. Does this project involve (1) blasting, and/or (2) other percussive activities that will be conducted by machines, such as jackhammers, mechanized pile drivers, etc.? 0 Yes C• No 5j. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? USFWS IPaC list and field verification of no suitable habitat during wetland delineation by SWCA Environmental Consultants. 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as an Essential Fish Habitat?* O Yes J No 6b. What data sources did you use to determine whether your site would impact an Essential Fish Habitat?* Essential Fish Habitat Mapper (NOAA) 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status?* O Yes i No 7b. What data sources did you use to determine whether your site would impact historic or archeological resources?* NCHPO Online Map Viewer (HPOWEB 2.0) accessed 7/18/2022 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA-designated 100-year floodplain?* O Yes • No 8c. What source(s) did you use to make the floodplain determination?* FIRM 3720138200J and FEMA's National Flood Hazard Layer (NFHL) Viewer Miscellaneous Please use the space below to attach all required documentation or any additional information you feel is helpful for application review. Documents should be combined into one file when possible, with a Cover Letter, Table of Contents, and a Cover Sheet for each Section preferred. Click the upload button or dreg and drop files here to attach document NC-5181 Blue Panther_CD_08052022.pdf 11.83MB SAW-2022-00534 .pdf 347.4KB File must be PDF or KMZ Comments PJD signed 5/6/2022 (SAW-2022-00534) and engineering drawings are attached. Wetlands and streams shown on Sheet C8 — C8.2 (pdf pgs. 12-14). Signature l By checking the box and signing below, I certify that: • The project proponent hereby certifies that all information contained herein is true, accurate, and complete to the best of my knowledge and belief; and • The project proponent hereby requests that the certifying authority review and take action on this CWA 401 certification request within the applicable reasonable period of time. • I have given true, accurate, and complete information on this form; I agree that submission of this PCN form is a "transaction' subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND I intend to electronically sign and submit the PCN form. Full Name: Kara Giblin Signature Date 8/12/2022 Action Id. SAW-2022-00534 U.S. ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT County: Bladen NOTIFICATION OF JURISDICTIONAL DETERMINATION Property Owner/Applicant: Matt Grugan Address: 750 Park of Commerce Drive Suite 200 Boca Raton, FL, 33487 Telephone Number: 678-488-1866 Size (acres) 0.8 Nearest Town Elizabethtown Nearest Waterway South River River Basin Cape Fear River USGS HUC 03030006 Coordinates Latitude: 34.6739 Longitude :-78.3557 Location description: Site is located at 6676 Hwy 210, PIN#'s 139300363641 & 139300472048 in Bladen County, NC, 28337. Indicate Which of the Following Apply: A. Preliminary Determination _ There appear to be wetlands on the above described property, that may be subject to Section 404 of the Clean Water Act (CWA)(33 USC § 1344) and/or Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403). The wetlands have been delineated, and the delineation has been verified by the Corps to be sufficiently accurate and reliable. Therefore, this preliminary jurisdiction determination may be used in the permit evaluation process, including determining compensatory mitigation. For purposes of computation of impacts, compensatory mitigation requirements, and other resource protection measures, a permit decision made on the basis of a preliminary JD will treat all waters and wetlands that would be affected in any way by the permitted activity on the site as if they are jurisdictional waters of the U.S. This preliminary determination is not an appealable action under the Regulatory Program Administrative Appeal Process (Reference 33 CFR Part 331). However, you may request an approved JD, which is an appealable action, by contacting the Corps district for further instruction. X There appear to be waters, including wetlands, on the above described property, that may be subject to Section 404 of the Clean Water Act (CWA)(33 USC § 1344) and/or Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403). The waters, including wetlands, have been delineated, and the delineation has been verified by the Corps to be sufficiently accurate and reliable. Therefore this preliminary jurisdiction determination may be used in the permit evaluation process, including determining compensatory mitigation. For purposes of computation of impacts, compensatory mitigation requirements, and other resource protection measures, a permit decision made on the basis of a preliminary JD will treat all waters and wetlands that would be affected in any way by the permitted activity on the site as if they are jurisdictional waters of the U.S. This preliminary determination is not an appealable action under the Regulatory Program Administrative Appeal Process (Reference 33 CFR Part 331). However, you may request an approved JD, which is an appealable action, by contacting the Corps district for further instruction. _ There appear to be waters, including wetlands, on the above described property, that may be subject to Section 404 of the Clean Water Act (CWA)(33 USC § 1344) and/or Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403). However, since the waters, including wetlands, have not been properly delineated, this preliminary jurisdiction determination may not be used in the permit evaluation process. Without a verified wetland delineation, this preliminary determination is merely an effective presumption of CWA/RHA jurisdiction over all of the waters, including wetlands, at the project area, which is not sufficiently accurate and reliable to support an enforceable permit decision. We recommend that you have the waters of the U.S., including wetlands, on your property delineated. As the Corps may not be able to accomplish this wetland delineation in a timely manner, you may wish to obtain a consultant to conduct a delineation that can be verified by the Corps. B. Approved Determination _ There are Navigable Waters of the United States within the above described property subject to the permit requirements of Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403) and Section 404 of the Clean Water Act (CWA)(33 USC § 1344). Unless there is a change in law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. Page 1 of 2 SAW-2022-00534 _ There are waters of the U.S., including wetlands, on the above described property subject to the permit requirements of Section 404 of the Clean Water Act (CWA) (33 USC § 1344). Unless there is a change in law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. _ We recommend you have the waters of the U.S., including wetlands, on your property delineated. As the Corps may not be able to accomplish this wetland delineation in a timely manner, you may wish to obtain a consultant to conduct a delineation that can be verified by the Corps. _ The waters of the U.S., including wetlands, on your property have been delineated and the delineation has been verified by the Corps. We strongly suggest you have this delineation surveyed. Upon completion, this survey should be reviewed and verified by the Corps. Once verified, this survey will provide an accurate depiction of all areas subject to CWA jurisdiction on your property which, unless there is a change in law or our published regulations, may be relied upon for a period not to exceed five years from the date of this notification. _ The waters of the U.S., including wetlands, have been delineated and surveyed and are accurately depicted on the plat signed by the Corps Regulatory Official identified below on . Unless there is a change in law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. _ There are no waters of the U.S., to include wetlands, present on the above described property which are subject to the permit requirements of Section 404 of the Clean Water Act (33 USC 1344). Unless there is a change in law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. _ The property is located in one of the 20 Coastal Counties subject to regulation under the Coastal Area Management Act (CAMA). You should contact the Division of Coastal Management in Morehead City, NC, at (252) 808-2808 to determine their requirements. Placement of dredged or fill material within waters of the US, including wetlands, without a Department of the Army permit may constitute a violation of Section 301 of the Clean Water Act (33 USC § 1311). Placement of dredged or fill material, construction or placement of structures, or work within navigable waters of the United States without a Department of the Army permit may constitute a violation of Sections 9 and/or 10 of the Rivers and Harbors Act (33 USC § 401 and/or 403). If you have any questions regarding this determination and/or the Corps regulatory program, please contact Thomas Charles at (910) 251-4101 or thorn as.p.charles(ausace.army.mil. Basis For Determination: This determination is only for the project area depicted Blue Panther Tower Delineation, Wetland Delineation Map, PIN#'s 139300363641 & 139300472048 in Bladen County, NC (0.8 Acres), dated 2/10//2022. D. Remarks: The project area exhibits wetland criteria as described in the 1987 Corps Wetland Delineation Manual and appropriate Regional Supplement. This determination is based on information submitted by SWCA and a desktop review by Thomas Charles (5/6/2022). E. Attention USDA Program Participants The delineation included herein has been conducted to identify the location and extent of the aquatic resource boundaries and/or the jurisdictional status of aquatic resources for purposes of the Clean Water Act for the particular site identified in this request. This delineation and/or jurisdictional determination may not be valid for the Wetland Conservation Provisions of the Food Security Act of 1985, as amended. If you or your tenant are USDA program participants, or anticipate participation in USDA programs, you should discuss the applicability of a certified wetland determination with the local USDA service center, prior to starting work. F. Appeals Information for Approved Jurisdiction Determinations (as indicated in Section B. above) If you object to this determination, you may request an administrative appeal under Corps regulations at 33 CFR Part 331. Enclosed you will find a Notification of Appeal Process (NAP) fact sheet and Request for Appeal (RFA) form. If you request to appeal this determination you must submit a completed RFA form to the following address: US Army Corps of Engineers South Atlantic Division Attn: Mr. Philip A Shannin Administrative Appeal Review Officer Page 2 of 2 SAW-2022-00534 60 Forsyth Street SW, Floor M9 Atlanta, Georgia 30303-8803 AND PHILIP.A. SHANNIN@USACE.ARMY.MIL In order for an RFA to be accepted by the Corps, the Corps must determine that it is complete, that it meets the criteria for appeal under 33 CFR part 331.5, and that it has been received by the Division Office within 60 days of the date of the NAP. Should you decide to submit an RFA form, it must be received at the above address by N/A. It is not necessary to submit an RFA form to the Division Office if you do not object to the determination in this correspondence. Digitally signed by Thomas Charles Thomas Charles Date: 2022.05.06 1 1:42:32 -04'00' Corps Regulatory Official: Date of JD: 5/6/2021 Expiration Date: 5/6/2026 The Wilmington District is committed to providing the highest level of support to the public. To help us ensure we continue to do so, please complete our Customer Satisfaction Survey, located online at https://regulatory.ops.usace.army.mil/customer-service-survey/_ Copy Furnished: SWCA Environmental Consultants Kara Giblin 201 Chatham Street Sanford, NC, 27330 Page 3 of 2 lif ! ' ti; tit .. firt• 4441. . 4. 4__14 - jir 1 '� �c s. <. eb OP t \q1.1111‘ S• :.r .. • PPO3 WA_PFO o W4mmkA_ll vl PP05 WB_PFO Y�PPB2 .X• ° � A AA .. PP01 I' WB_WET WA, PPO4 "Air- F' . WB_PFO i • ,•* • x • 1. ,.y :*. • • • • BLUE PANTHER TOWER DELINEATION 0 project Boundary 8laden County,NC Wetland Tomahawk,NC,34078-F3 Photo Point piz. i- Delineation Map NAd 1983 UTM Zone 17N N ,-,etV=-_•-r A Forested Wetland 78.3541`W 34.6742'Ntr Perennial Stream 1:2,000 Data Point Base neap:EsR1 AfoG15[Werra. [North Carolina] accessed February 2022 SWCA 180 Updated:Y10/2022 Fee' Profecl Nv.88021 Meters ENWR ONME N 1nL CONSULTANTS File:WeilandDeheeeiron 0 25 50 WHITE LAKE POLICE DEPARTMENT 1823 WHITE LAKE DRIVE ELIZABETHTOWN, NC 28337 PHONE: (910) 862-4057 ATTN.: CUSTOMER SERVICE HARRELLS VOLUNTEER FIRE DEPARTMENT 606 TOMAHAWK HWY HARRELLS, NC 28444 PHONE: (910) 532-4616 ATTN.: CUSTOMER SERVICE SITE cop34hta and (P) 1918-2010 Microsoft Corporation and/or its wWws. Al rights monad. VICINITY MAP FROM CHARLOTTE DOUGLAS INTERNATIONAL AIRPORT: GET ON 1-485 OUTER FROM OLD DOWD RD AND US-29 S/US-74 W/WILKINSON BLVD 3.3 MI; FOLLOW 1-485 OUTER AND US-74 BYP TO US-74 E IN UNION COUNTY 44.7 MI; CONTINUE ONTO US-74 E 36.6 MI; CONTINUE ONTO 1-74 E/US-74 E 11.0 MI; CONTINUE ONTO US-74 E 9.7 MI; CONTINUE ON 1-74 E TO LUMBERTON. TAKE EXIT 20 FROM 1-95 N/US-301 N 36.3 MI; TAKE NC-41 N, NC-87 S, US-701 N AND NC-41 N TO NC-210 S IN BLADEN COUNTY 41.6 MI. THE DESTINATION WILL BE ON THE RIGHT. DRIVING DIRECTIONS verticalbridge 700 DA�/< OF COvECE D BOCA ATO\ FL, 33L87 TEL: (561) 9L8-6367 BLUE PANTHER SITE No.: US-NC-5181 SITE ADDRESS (E-911) 6720NC210HWY HARRELLS, NC 28444 BLADEN COUNTY LATITUDE: 34° 40' 28.20" N LONGITUDE: 78° 21' 20.80" W TAX/PIN #: 1393-00-36-3641 ZONING: AR JURISDICTION: BLADEN COUNTY STATE: NORTH CAROLINA TOWER TYPE: GUYED TOWER TOWER HEIGHT: 300' (310' TO HIGHEST APPURTENANCE) NUMBER OF CARRIERS: 0 EXISTING, 1 PROPOSED USE: PROPOSED TELECOMMUNICATIONS TOWER AND UNMANNED EQUIPMENT FLOOD INFO SITE IS LOCATED WITHIN FEMA FLOOD MAP AREA 3720138200J DATED 01/05/2007 WITHIN FLOOD ZONE X. PROJECT SUMMARY VE DEVELOPER VB BTS, LLC 750 PARK OF COMMERCE DRIVE BOCA RATON, FL 33487 PHONE: (678) 488-1866 ATTN.: MATT GRUGAN POWER COMPANY FOUR COUNTY ELECTRIC MEMBERSHIP CORP. PHONE: (910) 872-7107 ATTN.: ANTHONY RAYNOR PROPERTY OWNER BESSIE L. WATTS 44 S. MUNN AVENUE, APT#6B EAST ORANGE, NJ 07018 PHONE: bleewatts@comcast.net ATTN.: BESSIE L. WATTS CONSULTANT KIMLEY-HORN AND ASSOCIATES, INC. 201 NORTH FRANKLIN STREET, SUITE 150 TAMPA, FL 33602 PHONE: (813) 620-1460 ATTN.: DAVID FRANKLIN CONTACTS SHEET NO. SHEET TITLE T1 COVER SHEET T2 APPENDIX B - BUILDING CODE SUMMARY -- SITE SURVEY (SHEET 1 OF 4) -- SITE SURVEY (SHEET 2 OF 4) -- SITE SURVEY (SHEET 3 OF 4) -- SITE SURVEY (SHEET 4 OF 4) N1 GENERAL NOTES Cl OVERALL PARCEL PLAN C1.1 OVERALL SITE PLAN C2 SITE PLAN C3 EQUIPMENT PAD LAYOUT C4 EQUIPMENT RACK DETAIL - FRONT C5 EQUIPMENT RACK DETAIL - REAR C6 CONCRETE PAD FOUNDATION DETAILS C7 FENCE, GATE, AND COMPOUND DETAILS C8 GRADING AND EROSION CONTROL PLAN C8.1 GRADING AND EROSION CONTROL PLAN C8.2 GRADING AND EROSION CONTROL PLAN C8.3 GRADING AND EROSION CONTROL PLAN C9 GRADING AND EROSION CONTROL DETAILS C10 ACCESS ROAD DETAILS C11 SITE SIGNAGE DETAILS C12 WAVEGUIDE BRIDGE DETAILS C13 ANTENNA AND TOWER ELEVATION DETAILS C14 GUY ANCHOR FENCE DETAIL M1 MECHANICAL PLAN AND NOTES El ELECTRICAL NOTES E2 UTILITY SERVICE ROUTING PLAN E3 OVERALL UTILITY ROUTING PLAN E3.1 ENLARGED UTILITY ROUTING PLAN E4 METER RACK DETAILS - FRONT E4.1 METER RACK DETAILS - REAR E5 ELECTRICAL SINGLE LINE DIAGRAM E5.1 ELECTRICAL SINGLE LINE DIAGRAM E6 PANEL SCHEDULE E7 ELECTRICAL DETAILS E8 GROUNDING NOTES E9 GROUNDING PLAN E10 GROUNDING SINGLE LINE DIAGRAM Ell GROUNDING DETAILS E12 GROUNDING DETAILS E13 GUY WIRE GROUNDING AND FENCE DETAILS E14 GUY WIRE GROUNDING AND FENCE DETAILS SHEET INDEX BLADEN COUNTY, PLANNING DEPARTMENT 450 SMITH CIRCLE DRIVE ELIZABETHTOWN, NC 28337 PHONE: (910) 862-6745 ATTN.: CUSTOMER SERVICE PERMIT INFORMATION verticalbridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 :REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM —LICENSER. ♦♦%*tSIl UI,,, ♦ ^ e..eeeeee < / #, • 0 .•• __SS/0 . "4, #• : SEAL •• :77 1 047704 : Z . z . •••, tic I NEF�•' J PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET COVER SHEET —SHEET NUMBER. T1 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 202 2018 APPENDIX B I Frontage area increases from Section 506.2 are computed thus: Perimeter fronts having 20 feet = BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS 9. which a public way or open space minimum width (F) b. Total Building Perimeter - (P) (EXCEPTAND 2-FAMILYDWELLINGS AND TOWNHOUSES) . Ratio (= (F/P) ACCESSIBLE DWELLING UNITS 2018 APPENDIX B duce the following data on the building plans sheet 1 or 2) (Reproduce d d. W =Mininimum width of public way = (W) (SECTION 1107) e. Percent of frontage increase 4 = 100[P/P-0.25] x PK/30 = (%) TOTAL ACCESSIBLE ACCESSIBLE TYPE A TrexA TYPE TYPES BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJEC VERTICAL BRIDGE - BLUE PANTHER ' Unlimited area applicable under conditions of Section 507. ' Maximum Building Area = total number of stories in the building x D (maxim stories) (506.2). UNITS urars REQUIRED UNITS PROVIDED Doris REQUIRED UNITS PROVIDED UNITS REQUIRED UNITS PROVIDED • ,M ACC BLE UNITS ROVmpD STRUCTURAL DESIGN (PROVIDE ON THE STRUCTURAL SHEETS IF APPLICABLE) Name of Project: ^ The maximum area of open parking garages must comply with Table 406 .. The maximum area of au traffic DESIGN LOADS: Address: 6720 NC 210 HWY. HARRELLS. NC Zip Code 28444 david.cousins control towers must comply with Table 412.3.1. ' Frontage increase is based on the unsprinklered area val(i,p T 506.2. Importance Factors: Snow (Is) NOTE: STRU RAL Owner/Authorized Agent: DAVID COUSINS Phone # ( 813 ) 620 -1460 E-Mail kimley-horn.com _ Seismic (Ili) ANALYSIS <aMPLETED Owned By: ❑ City/County IX Private ❑ 8ta Code Enforcement Jurisdiction: ❑ City❑X County HARRELLSState E AL ABLE HEIGHT ACCESSIBLE PARKING (SECTION 1106) Live Loads: Roof psf BY TO OWNER. SEE ANAL a=IS BY OTHERS Mezzanine LOT OR PARKING GSPACES TOTAL# OF PARKING 4OFACCEssLESPACES• DveD mm TOTAL SO 'O psf Floor FO' ADDITIONAL CONTACT: DAMD R. COUSINS, P.E. (4047704) ALLowABLE SHOWN00 PLANS CODE REFERENCE AREA REQUIRED PROVIDED REGULAR WITH v .ACES wrrx ACCESSIBLE psf 'UCTURAL DATA. Building Height in F. (Table 50 5. ACCESS AISLE 1327 A. ESS 8' Access PROVIDED Ground Snow Load: psf DESIGNER FIRM NAME LICENSE TELEPHONE# E-MAIL FIRM Building Height in &ode 504.4) Le AISLE Architectural ' able Wind Load: Basic Wind Speed �. (A C'L-7) Civil KIMI EY-HORN & ASSOC_ DAVID R (MINNS 047704 (fi25) 274-5032 dondeousins@kimlerhom.con Provide code reference¢'shown on Plans" Raatity is not based on Table 504.3 r504.4. Exposure Category Electrical KINLEY-HORN & ASSOC. CGRBIN C- HABDY 040828 919 677-2000 co8in.mmt6kimlerhornnorn Fire Alarm \''' (_)":ti Plumbing ) Mechanical (_) ( / SEISMIC DESIGN CATEGORY: ❑ A ❑ B ❑ C ❑ D Sprinkler -Standpipe (__) FIRE PROTECTION REQUIREMENTS PLUMBING FIX ' RE REQUIREMENTS Provide the following Seismic Design Parameters: Structural (_) ( - BLE 2902.1) Risk Category (Table 1604.5) ❑ I II ❑ III ❑ IV Retaining Walls >5' High ( ) BUILDING ELEMENT FIRE RATING DETAIL # D # SHEET SHE Spectral Spectral Response Acceleration Ss %g Si %g Other �) SEPARATION aD1aTANCEN RFu'n D / VIBE x AND FOR RATED ("Other" should include firms and individuals such as truss, precast, pre-engineered, interior designers, etc.) (FEET) (W/ REDUCTION) SHEET RATED ASSEMBLY PENETRATION - TED JOINTS USE MALEwAFEMALE T T0RELO8ET8 r a RMALO MALE LAVATORIES EEMALE UNISE5 SHOWERS boo s DRINKING REGULAR O FOUNTAINS ACCESSIBLE Site Classification (ABLE 7) VA ❑ B ❑ C ❑ D ❑ E ❑ F swemral Frame, SPACE EXISVGBasic Data Source: ■ Field Test ❑ Presumptive ❑ Historical Data structural system ❑ Bearing Wall ❑ Dual Moment Frame 2018 NC BUILDING CODE: ®New Building ❑Addition El Renovation including°alum., girders, W w/Special ❑ 1" Time Interior Completion trusses REQ'D ❑ Building Frame ❑ Dual w/Intermediate R/C or Special Steel ❑ Shell/Core - Contact the local inspection jurisdiction for possible additional Bearing Walls ❑Moment Frame ❑Inverted Pendulum procedures and requirements Exterior Analysis Proce• r . y Simplified 0 Equivalent Lateral Force ❑Dynamic ❑ Phased Construction - Shell/Core- Contact the local inspection jurisdiction for Nomb Architectur- , Mechanical, Components anchored? ❑ Yes ❑ No possible additional procedures and requirements Easy SPECIAL APPROVALS ❑ lip ❑Cho ter 14 2018 NC EXISTING BUILDING CODE: EXISTING: ❑ Prescriptive Repair West Special approval: S I a al: ocal Jurisdiction, Department of Insurance, OSC, DPI, DIMS, etc, describe below ) LATERALD.. GN CONTROL: Earthquake ❑ Wind ❑ p p Alteration: ❑ Level I ❑ Level II ❑ Level III South p • ❑ Historic Property ❑ Change Interior SOIL B -f G CAPACITIES: Field Test test of Use CONSTRUCTED: CURRENT OCCUPANCY(S) 3): TELECOMMUNICATIONS SITE Nonheanng Walls and (provide copy of report) psf Imp the g Presumptive Bearing f ps (date) (Ch. Partitions Pile size, type, and capacity capacity RENOVATED: (date) PROPOSED OCCUPANCY(S) (Ch. 3):TEIECOMMUNICATONS SITE Exterior walls RISK CATEGORY (Table 1604.5): Current: ❑ I ❑ II ❑ HT ❑ IV North Proposed: ❑ I ❑ IT ❑ III ❑ TV East West south ENERGY SUMMARY 2018 APPENDIX B BASIC BUILDING DATA Construction Type: El LA ❑ II ❑ BI-A ❑ IV ❑ V-A rowan watts endue-tonesENERGY REQUIREMENTS: BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJ ' TS -A f cheek all that apply) ❑ 1-B ❑ Il-B ❑ II1-B ❑ Sprinklers: ❑ No ❑Partial ID Yes ❑NFPA 13 ❑NFPA 13R ❑ N 13D Floor Construction Including supporting beams s djsists The following data shall be considered minimum and any special attribute required to meet the energy codes. 11 also be provided. Each Designer shall furnish the required portions of the project information for the plan d. a sheet. If performance method, state the annual energy cost for the standard reference design vs annual energy c.: for the MECHANICAL DESIGN (PROVIDE ON THE MECHANICAL SHEETS IF APPLICABLE) Standpipes: ❑ No ❑ Yes Class ❑ I ❑ II ❑ III ❑ Wet ❑ D Floor ceiling Assembly proposed design. MECHANICAL SUMMARY Fire District: ❑ No ❑ Yes Flood Hazard Area: ❑ No es Columns Supporting Floors Special Inspections Required: ❑ No ❑Yes (Contact the local inaro n jurisdiction for additional Roof construction, including building envelope complies with code: ❑ No ❑ Yes (The ramandn of this section . n applicable) MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT procedures and re meats.) supporting beams and joists I_ Roof Ceiling Assembly Exempt Building: El No ❑ Yes (Provide code or statutory reference). Thermal Zone r Columns Supporting Roof bulb - winter dry bulb - Gross B ng Area Table Shan Enclosures - Exit Climate Zone: ❑ 3A ❑ 4A ❑ SA summer dry bulb: FtooR EXISTING (sQ Fr) NEW (So Fr) Sun -TOTAL Shan Enclosures - other Method of Compliance: Energy Code ❑ Performance ❑ Prescri I ire 3`^ Floor Interior ¢ergo conditions \ 2°J Floor Corridor separation ❑ ASHRAE 90.1 Performance ❑ Pre s ptive "Other" winter dry bulb: Occupancy/Fire Barriers., anon (If specify source here) summer bulb: Mezzanine PaDytElre wall sepmad. relative humidity: 1. Floor Basement Smoke Barrier Separ. on THERMAL ENVELOPE (Prescriptive method only) smoke Partition Building heating load: L Patron✓Dweui„uniu Roof/ceiling Assembly (each assembly) sleeping Un epsmtion Descri tion ofassembl P Y Building cooling load: ALLOWABLE AREA Incidents se Separation U-Value of total assembly: Primary Occupancy Classification(s): Select one Select one Select one Select one Select one Select on " Indica section number permitting reduction R-Value of insulation: Skylights in each assembly: Mechanical S Coaditia ' System pacing g Assembly ❑ A-1 ❑ A-2 ❑ A-3 ❑ A-4 ❑ A-5 U-Value of skylight: Unitary total square footage of skylights in each as: mbly: description Business ❑ Educational ❑ PERCENTAGE OF WALL OPENING CALCULATIONS heating a Iency: cooling ciency: Factory 0E-1 Moderate 0E-2 Low Exterior Walls (each assembly) size •. tegory of unit: az Hardous ❑ H-1 Detonate ❑ H-2 Deflagrate E H-3 Combust ❑ H-4 Health IDH-5 ' PM FIRE SEPARATION DISTANCE (Peer) PROM PROPERTY LwE5 DEGREE OF OPENINGS PROTECTION ALLOW..LEAaEA (%) ACTDAL SHOWN ON s (%) U-Value of total Description of assembly: Boil. Ian category. If oversized, state reason.: Institutional ❑ I-1 Condition ❑ 1 ❑ 2 (TABLE 705.8) R-Value of luslslatianmbly CI1-2Condition ❑ 1 ❑ 2 Openings (windows or doors th glazing)hiller Size category. If oversized, state reason.:. ❑ I-3 Condition ❑ 1 ❑ 2 ❑ 3 ❑ 4 ❑ 5 U-Value of assem.I Solar heat gain c , efficient: ist equipment efficiencies: ❑ 1-4 projection fact' Mercantile ❑ R-Val -s. Residential ❑ R-1 ❑ R-2 ❑ R-3 ❑ R-4Door Storage ❑ S-1 Moderate E S-2 Low ❑ High -piled ❑ Parking Garage ❑ Open ❑ Enclosed ❑ Repair G. ge LIFE SAFETY SYSTEM REQUIREMENTS Walls below grade (each ,sembly) Description of . sembly: 2018 APPENDIX B Utility and Miscellaneous ❑ Emergency Lighting: ❑ No ❑ Yes U-Value of t a t assembly: BUILDING CODE SUMMARY FOR ALL COMMERCIAL PR 1 CTS Accessory Occupancy Classification(s): Exit Signs: ❑ No ❑ Yes R-Value o> nsula[ion: - , Incidental Uses (Cable 509): Fire Alarm: ❑ No ❑ Yes ELECTRICAL DESIGN (PROVIDE ON THE ELECTRICAL SHEETS IF APPLICABLE) Special Uses (Chapter 4 - List Code Sections): Smoke Detection Systems: ❑ No ❑ Yes ❑ Partial Carbon Monoxide Detection: ❑ No ❑ Yes Floors over u nditianed space (each assembly) 'ption Cl Special Provisions: (Chapter 5 - List Code Sections): De < of assembly: U aloe of total assembly: ELECTRICAL SUMMARY Mixed Occupancy: ❑ No ❑ Yes Sepamtir : Hr. Exception: -Value of insulation: ELECTRICAL SYSTEM AND EQUIPMENT ❑ Non -Separated Use (508.3) - The require. . e of construction for the building shall be determined by applying t r height and area limitations for each of the applicable LIFE SAFETY PLAN REQU . ENTENTS Life Safety Plan Sheet #: Flo s slab on grade Method of Compliance: Energy Code ❑ PerformancePrescriptive occu.. •. es to the entire building. The most restrictive type of determined, building. �� ❑ Fire and/or smoke rated wall locations (Chapter Pt, Description of assembly: U-Value of total assembly: ASHRAE 90.1 ❑ Performance ❑ Prescriptive con ..coon, so shall apply to the entire ❑ Assumed and real property line locations (if not o. 'he site plan) R-Value of insulation: Lighting schedule (each fixture type) `\ El Separated Use 508.4 Bee bet. for area calculations for each sea the area of the occupancy hall ( ) story, P y s ❑ Exterior to die to lines 705.8 HorizontaUvertical requirement: B la in fixture be su.r that the sum of the ratios of the actual floor area of each use divided b Y wall opening with respect :.- a assumed P g area wi p properly ( ) slab heated: rap type required in fixture the towable floor area for each use shall not exceed 1. ❑ Occupancy Use for each area as it relates to . cupant load calculation (Table 1004.1.2) ❑ Occupant loads for each area numberoflamps ballast type used in the fixture Actual Area of°comer; A + Actual Area of Occupancy B - I number of ballasts in fixture Allowable Area of°ccu.. cyA Allowable Area of Occupancy B + + ...... _ < 1.00 ❑ Exit access travel distances (1017) ❑ Common path of travel distances (T- .lee 1006.2.1 & 1006.3.2(1)) ❑ Dead end lengths (1020.4) total wattage per fixture total interior wattage sped s vs. allowed (whole building or space by space) total exterior wattage sp> led vs. allowed ❑ Clear exit widths for each exi . Oar ❑ Maximum calculated occu nt load capacity each exit door can accommodate based on egress (1005.3) Additional Efficiency Pa o. ge Options S0OR> No. DESCRu 0NAND sE (A) BLDGAREA PER STORY(AcruAL) (B) r TABLE AREA (C) RE AREA INCREASE (D) ALLOWABLE AREA PER STORY OR UNLIMITED• I . width El Actual occupant load f ., hexit door ❑ Asepar-dteschematic ,anindicatingwhere fire rated flom/ceilingand/or roof strucnveisprovidedfor ofoccup. NOTE: SCOPE OF WORK INCLUDES INSTALLATION OF CAST IN PLACE CONCRETE PAD, PREFABRICATED singthe2018, CC; not required for ASHRAE90.1) (When using the 2018 ❑C4o6.2 -orEfficientlVACEquipmentPerformance ❑ C40-. Reduced Lighting Power Density purposes yseparation ❑ Location ofdom: with panihardware (1010.1.10) EQUIPMENT CABINETS AND GENERATOR. ❑ .16.4 Enhanced Digital Lighting Controls ❑ Locationof...rswithdelayedegresstooksandtheamountofdelay(1010.1.9.7) NO NEW BUILDING BEING CONSTRUCTED. . C406.5On-Sim Renewable Energy ❑ locks C406.7 Air System Location o'doors with electromagnetic egress (1010.1.9.9) E Locatio ' of doors equipped with hold -open devices UOutdoor Redio rd Energy ❑ C406.7 Reduced Energy Use in Service Water Heating ❑ Loc. -''an of emergency escape windows (1030) ❑ T r square footage of each fire area (202) ❑ he square footage of each smoke compartment for Occupancy Classification 1-2 (407.5) I. Note any code exceptions or table notes that may have been utilized regarding the items above ver tic la idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL (561) 948-6367 PROJECT INFORMATION` SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley>» NORTH PHONE WWW.KIMLEY-HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 Horn SUITE 150 :REV:=DATE:—ISSUED FOR:=BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER` ,,%*t8IelII, 4%4N CAR '* ••••••lie •C /�///#I• ♦ • . • SEAL •• 77 t 047704 : Z • #, %e•%; VC I NV-x-o•• Jam• .*••••••N• 0 • .,*..q / N ; • ,; * PROJECT NUMBER. CKHA 140064078 BY: CHECKED BY. CDRAWN TDM TWD TITLE` _SHEET APPENDIX B - BUILDING CODE SUMMARY —SHEET NUMBER- T2 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Hour and Associates, Inc. shall be without liability to IGmley-Horn and Associates, Inc. Copyright IGmley-Hour and Associates, Inc., 2022 1.00 GENERAL NOTES 1.01 ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS AND SPECIFICATIONS. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE STATE, LOCAL AND NATIONAL CODES, ORDINANCES AND OR REGULATIONS APPLICABLE TO THIS PROJECT. 1.02 THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE PROJECT MANAGER AND/OR ENGINEER AND BE RESOLVED BEFORE PROCEEDING WITH WORK. WHERE THERE IS A CONFLICT BETWEEN DRAWING AND VERIZON SPECIFICATIONS, THE VERIZON PROJECT ENGINEER SHOULD BE CONTACTED FOR CLARIFICATION. 1.03 ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE PROJECT MANAGER AND/OR ENGINEER SO THAT PROPER REVISIONS MAY BE MADE. MODIFICATION OF DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL OF THE PROJECT MANAGER AND/OR ENGINEER. 1.04 CONTRACTOR SHALL REVIEW AND BE FAMILIAR WITH SITE CONDITIONS AS SHOWN ON THE ATTACHED SITE PLAN AND/OR SURVEY DRAWINGS. 1.05 WAVEGUIDE BRIDGE AND EQUIPMENT CABINETS ARE SHOWN FOR REFERENCE ONLY. REFER TO SEPARATE DRAWINGS FOR SPECIFIC INFORMATION. 1.06 ALL FINISHED GRADES SHALL SLOPE MINIMUM 1/4 IN./FT. AWAY FROM EQUIPMENT IN ALL DIRECTIONS. CONTRACTOR SHALL SLOPE SWALES AS REQUIRED ALONG EXISTING TERRAIN TO DRAIN AWAY FROM COMPOUND AND ACCESS DRIVE. 1.07 THE PROPOSED TOWER AND TOWER FOUNDATIONS WERE DESIGNED BY OTHERS. TOWER INFORMATION PROVIDED ON THESE PLANS ARE PROVIDED FOR REFERENCE PURPOSES ONLY. NOTIFY ENGINEER OR PROJECT MANAGER OF ANY CONFLICTS OR DISCREPANCIES. CONTRACTOR TO OBTAIN COPY OF TOWER DESIGN DRAWINGS, IF AVAILABLE, FROM VERIZON PROJECT MANAGER TO CONFIRM COAX ROUTING AND ANTENNA MOUNT INFORMATION. 1.08 THE CONTRACTOR SHALL PROVIDE ADEQUATE EXCAVATION SLOPING, SHORING, BRACING, AND GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL SAFETY ORDINANCES. 1.09 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY CONSTRUCTION ACTIVITIES TO THE EXISTING ACCESS ROAD AND COMPOUND GRAVEL AREAS. ANY NEW FILL MATERIALS SHALL BE COMPACTED. 1.10 THE CONTRACTOR IS HEREBY NOTIFIED THAT PRIOR TO COMMENCING CONSTRUCTION, HE IS RESPONSIBLE FOR CONTACTING THE UTILITY COMPANIES INVOLVED AND SHALL REQUEST A VERIFICATION AT THE CONSTRUCTION SITE OF THE LOCATIONS OF THEIR UNDERGROUND UTILITIES AND WHERE THEY MAY POSSIBLY CONFLICT WITH THE PLACEMENT OF IMPROVEMENTS AS SHOWN ON THESE PLANS. THE CONTRACTOR OR ANY SUBCONTRACTOR FOR THIS CONTRACT WILL BE REQUIRED TO NOTIFY "NORTH CAROLINA 811" 48 HOURS IN ADVANCE OF PERFORMING ANY WORK BY CALLING THE TOLL FREE NUMBER (800) 632-4949 (OR 811). ANY UTILITIES DAMAGED BY CONSTRUCTION ACTIVITIES SHALL BE REPAIRED BY THE CONTRACTOR, AT NO EXPENSE TO THE OWNER. 1.11 CONTRACTOR TO PROVIDE DUMPSTER AND PORTABLE TOILET FACILITY DURING CONSTRUCTION. 1.12 CONTRACTOR TO PROVIDE STYMIE LOCK OR EQUIVALENT AS APPROVED BY VERTICAL BRIDGE PROJECT MANAGER. 1.13 CONTRACTOR TO PROVIDE ANY NECESSARY SIGNAGE PER VERTICAL BRIDGE PROJECT MANAGER'S INSTRUCTIONS. SEE DETAIL ON SHEET C11. 2.00 EQUIPMENT FOUNDATION NOTES 2.01 FOUNDATIONS ARE DESIGNED FOR A PRESUMPTIVE ALLOWABLE SOIL BEARING CAPACITY OF 2,000 PSF. CONTRACTOR SHALL VERIFY SOIL CONDITIONS AND BEARING CAPACITY PRIOR TO CONSTRUCTION. 2.02 EXCAVATE A MINIMUM 18" BELOW PROPOSED EQUIPMENT FOUNDATIONS OF EXPANSIVE, ORGANIC, UNCONSOLIDATED OR OTHERWISE UNACCEPTABLE MATERIAL AND REPLACE WITH WELL -COMPACTED MATERIAL ACCEPTABLE TO VERIZON. 2.03 CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING, PROTECTING, AND RELOCATING AS REQUIRED ALL SERVICE AND UTILITY LINES IN VICINITY OF THE WORK SITE. ALL EXCAVATIONS NEAR THESE LINES TO BE CARRIED OUT WITH EXTREME CAUTION. COORDINATE ALL RELOCATIONS WITH THE PROPERTY OWNER. 2.04 CONTRACTOR TO CUT/FILL EXISTING COMPOUND SUBSOIL TO PROVIDE AN AREA AS LEVEL AS POSSIBLE FOR THE EQUIPMENT FOUNDATIONS. ALL FILL AREAS ARE TO BE FILLED WITH SUITABLE MATERIALS. FILL MATERIALS ARE TO BE PLACED, COMPACTED, AND TESTED IN MAXIMUM LAYERS OF 8". COMPACTION OF ALL FILL MATERIAL SHALL ACHIEVE 95 PERCENT OF MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM D 698. ALL TESTS MUST MEET THE MINIMUM SPECIFIED SOIL BEARING CAPACITY. COMPACTION TESTING IS BY THE GEOTECHNICAL TESTING COMPANY DESIGNATED FOR THE PROJECT. SCHEDULING AND COORDINATION IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. REPORTS OF ALL TESTING ARE TO BE PROMPTLY DELIVERED OR FAXED TO THE VERTICAL BRIDGE PROJECT MANAGER. 2.05 CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST REVISION TO ACI-318 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. 2.06 CONCRETE SHALL HAVE A SLUMP BETWEEN 3" AND 6". 2.07 FIBERS FOR CONCRETE SHALL BE FIBERMESH 650, 100 PERCENT VIRGIN POLYPROPYLENE FIBRILLATED FIBERS, e3 PATENTED TECHNOLOGY PATENTED TECHNOLOGY, CONTAINING NO REPROCESSED OLEFIN MATERIALS. THE FIBERS SHALL CONFORM TO ASTM C1116 TYPE III AND MANUFACTURED SPECIFICALLY FOR THE SECONDARY REINFORCEMENT OF CONCRETE. 2.08 THE FIBERS SHALL BE MANUFACTURED IN AN ISO 9001:2008 CERTIFIED MANUFACTURING FACILITY. UNLESS OTHERWISE STATED, FIBERMESH 650 MACRO -SYNTHETIC FIBERS SHALL BE ADDED TO THE CONCRETE AT THE BATCHING PLANT AT THE RECOMMENDED APPLICATION RATE OF 3 LBS/YD3 AND MIXED FOR A SUFFICIENT TIME (MINIMUM 5 MINUTES AT FULL MIXING SPEED) TO ENSURE UNIFORM DISTRIBUTION OF THE FIBERS THROUGHOUT THE CONCRETE. FIBROUS CONCRETE REINFORCEMENT SHALL BE MANUFACTURED BY FIBERMESH, 4019 INDUSTRY DRIVE, CHATTANOOGA, TN 37416 USA, TEL: 800 621-1273, WEBSITE: WWW.FIBERMESH.COM 2.09 AT THE REQUEST OF THE VERTICAL BRIDGE PROJECT MANAGER, TEST CYLINDERS SHALL BE MOLDED AND LABORATORY CURED IN ACCORDANCE WITH ASTM C31. THREE CYLINDERS SHALL BE TAKEN FOR EACH DAY'S CONCRETE PLACEMENT. CYLINDERS SHALL BE TESTED IN ACCORDANCE WITH THE LATEST REVISION TO ASTM C39. 2.10 CHAMFER ALL EXPOSED EXTERNAL CORNERS OF CONCRETE WITH 3/4" x 45° CHAMFER, UNLESS OTHERWISE NOTED. 2.11 CONCRETE FORMWORK IS TO BE STRIPPED WITHIN 48 HOURS. VIBRATION OF THE CONCRETE MUST ASSURE THAT HONEYCOMBING WILL BE AT A MINIMUM. MECHANICAL VIBRATION OF ALL CONCRETE IS REQUIRED UNLESS OTHERWISE DIRECTED BY VERTICAL BRIDGE' PROJECT MANAGER. ABOVE GRADE CONCRETE IS TO BE RUBBED AND PATCHED TO ASSURE SMOOTH FINISH AT TIME OF FORMS REMOVAL. CONTRACTOR SHALL PROVIDE A BROOM FINISH ON THE TOP SURFACE OF THE EQUIPMENT FOUNDATION UNLESS OTHERWISE DIRECTED BY VERTICAL BRIDGE' PROJECT MANAGER. 2.12 TOPS OF CONCRETE FOUNDATION MUST BE WITHIN 0.02' OF ELEVATION REQUIRED. 2.13 TOP OF FOUNDATION FINISH TO BE LEVEL ± " IN 10'. 2.14 TOP OF FOUNDATION TO HAVE MEDIUM BROOM FINISH. 2.15 CONTRACTOR SHALL REFER TO DRAWINGS OF OTHER TRADES AND VENDOR DRAWINGS FOR EMBEDDED ITEMS AND RECESSES NOT SHOWN ON THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL VERIFY PLACEMENT OF EQUIPMENT AND LOCATION OF CONDUIT FOR MANUFACTURER'S AND VENDORS SPECIFICATIONS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL OPENINGS AND SLEEVES FOR PROPER DISTRIBUTION OF ALL UTILITIES. vertic la idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY-HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: -DATE: -ISSUED FOR: -BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tS,l UI,s, ♦ x\\ CARS '. O":OESS/p�.'2 *: SEAL •. 7' 1 047704 : Z • z_ . PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET GENERAL NOTES -SHEET NUMBER. N1 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Hom and Associates, Inc. Copyright Kimley-Hom and Associates, Inc., 2022 K:\TAM_Wireless\140064 — Vertical Bridge\078 — NC-5181 Blue Panther\Drawings\CD\ECar—GB.dwg ---- 08/05/22 8:42 AM by: Tim.Merchant TOWER SETBACKS TO PROPERTY LINES (FROM TOWER CENTER) NORTHWEST 340'-4" SOUTHEAST 366'—O" NORTHEAST 340'—O" SOUTHWEST 572'-10" LANDS N/F DALPHIA ANN MURPHY PIN 139300260664 PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 50' X 50' PREMISES (±2,500 SQ. FT.) (SEE SHEET C2) PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 300' GUYED TOWER (SEE SHEET C13) •WA_PFO WETLAND AREA LANDS N/F ROSETTA L & MICHAEL F JOHNSON PIN 139300155712 NOTES: 1. WETLAND AREA (DISTURBED): WA_PFO WETLAND ACRES = 0.0552 WB_PFO WETLAND ACRES = 0.0515 TOTAL WETLAND AREA = 0.1067 2. INFORMATION BASED ON THE 2022 DELINEATION REPORT PER EBI CONSULTING. LANDS N/F JEANETTE ETVIRE & DANIEL MILLER PIN 139300378161 PROPOSED VERTICAL BRIDGE I DEVELOPMENT, LLC 30' WIDE ACCESS AND UTILITY EASEMENT LANDS N/F LEE LEROY PIERCE PIN 139300356509 LANDS N/F LEE CLARETHA PIN 139300472048 LANDS N/F SLEEPY CREEK FARMS INC PIN 139300461066 EXISTING PROPERTY LINE (TYP) PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 12' WIDE ACCESS ROAD TO EXISTING DRIVE (±1172' LONG) (EXISTING UNUSED SANDY PATH TO BE IMPROVED TO VERTICAL BRIDGE STANDARDS) PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 20' WIDE ACCESS AND UTILITY EASEMENT WB_PFO WETLAND AREA SURVEY NOTE: 1. VERTICAL BRIDGE DEVELOPMENT, LLC STAFF SHALL COORDINATE WITH THE PROPERTY OWNER TO OBTAIN THE PROPER EASEMENT AGREEMENTS TO CONSTRUCT AND MAINTAIN EQUIPMENT IN AND AROUND THE TOWER COMPOUND. 2. PROPOSED COMPOUND LAYOUT BASED ON SURVEY PROVIDED BY GEOLINE SURVEYING, INC DATED 02/09/22 AND SITE VISIT ON 5/25/21. i 1 \ OVERALL PARCEL PLAN C 1� SCALE: 1 " = 200' NOiTH/ NORTH / 0 100 200 400 GRAPHIC SCALE: 1" = 200' verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY -PLANS PREPARED BY: 201 Kimleyo NORTH PHONE WWW.KIMLEY-HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 Horn SUITE 150 :REV:=DATE:—ISSUED FOR:=BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,%*tS,l UI,4,, 4.,4N CAR '* O;•oFESSioy•e/G.: SEAL •• 77 : 047704 : Z z. • • , . ..,-6 �•••: c j NEB.••• Jam: .. •••...••• O . PROJECT NUMBER. CKHA 140064078 BY: CHECKED BY EDRAWN TDM TWD TITLE. _SHEET OVERALL PARCEL PLAN -SHEET NUMBER C1 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to IOmley—Horn and Associates, Inc. Copyright IGmley—Horn and Associates, Inc., 2022 TOWER SETBACKS TO PROPERTY LINES (FROM TOWER CENTER) NORTHWEST 340'-4" SOUTHEAST 366'-0" NORTHEAST 340'-0" SOUTHWEST 572'-10" — PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 100' X 100' PREMISES (±10,000 SQ. FT.) (SEE SHEET C2) PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 300' GUYED TOWER (SEE SHEET C13) WA_PFO WETLAND \ ACRES = 0.0552 / i WA_PFO WETLAND ACRES = 0.552 PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 30' WIDE ACCESS AND UTILITY EASEMENT // 1 / /// I / / SURVEY NOTE: 1. VERTICAL BRIDGE DEVELOPMENT, LLC STAFF SHALL COORDINATE WITH THE PROPERTY OWNER TO OBTAIN THE PROPER EASEMENT AGREEMENTS TO CONSTRUCT AND MAINTAIN EQUIPMENT IN AND AROUND THE TOWER COMPOUND. 2. PROPOSED COMPOUND LAYOUT BASED ON SURVEY PROVIDED BY GEOLINE SURVEYING, INC DATED 02/09/22 AND SITE VISIT ON 5/25/21. WB_PFO WETLAND ACRES = 0.0515 TRANSITION FROM 30' WIDE TO 20' WIDE ACCESS AND UTILITY EASEMENT AT PROPERTY BOUNDARY OVERALL SITE PLAN SCALE: 1" = 100' NOTES: 1. WETLAND AREA (DISTURBED): WA_PFO WETLAND ACRES = 0.0552 WB_PFO WETLAND ACRES = 0.0515 TOTAL WETLAND AREA = 0.1067 2. INFORMATION BASED ON THE 2022 DELINEATION REPORT PER EBI CONSULTING. 0 PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 12' WIDE ACCESS ROAD TO EXISTING DRIVE (±1172' LONG) (EXISTING UNUSED SANDY PATH TO BE IMPROVED TO VERTICAL BRIDGE STANDARDS) PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 20' WIDE ACCESS AND UTILITY EASEMENT 50 100 200 GRAPHIC SCALE: 1" = 100' verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley* NORTH PHONE WWW.KIMLEY—HORN.COM FRANKUN STREET, TAMPA, FL 336D2 (813) 620-1460 Horn SURE 150 :REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM LICENSER ,,%*tSIl UI,,, ,.4N CAR0 '. SEAL •• o • 047704 : z_ . PROJECT NUMBER' CKHA 140064078 BY: CHECKED BY. CDRAWN TDM TWD TITLE. _SHEET OVERALL SITE PLAN —SHEET NUMBER. Cl .1 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 9' X 18' VEHICLE PARKING AND TURN AROUND AREA PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 12' WIDE GRAVEL ACCESS ROAD PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 50' X 50' CHAIN LINK FENCED COMPOUND W/ 3 STRANDS OF BARBED WIRE (8' MIN. HEIGHT) FUTURE CO —LOCATOR — (TYP OF 3) PROPOSED VERIZON WIRELESS 10' H—FRAME W/INTEGRATED LOAD CENTER, DISCONNECT, TELCO BOX, RRU'S AND RAYCAPS PROPOSED VERIZON WIRELESS 10' X 4' CONCRETE PAD WITH EQUIPMENT CABINET (SEE SHEET C6) PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 100' X 100' PREMISES (±10,000 SQ. FT.) 10' NO SPARK ZONE RADIUS CENTERED ON FILL VALVE WITH MANUAL SHUT OFF PROPOSED VERIZON WIRELESS 8' X 3'-6" CONCRETE PAD WITH PROPANE TANK (SEE SHEET C6) / fl _/\ • PROPOSED 12' SWING GATE •x—x SITE PLAN SCALE: 1" = 15' --x- 4'-0" 5'-0" PROPOSED MULTIGANG METER RACK PROPOSED VERIZON WIRELESS 19' X 25' WITH 6'-6" X 3'-6" EXTENSION EQUIPMENT AREA (±497 SQ. FT.) (SEE SHEET C3) - PROPOSED VERIZON WIRELESS ±40 LF OF 2' WIDE WAVEGUIDE BRIDGE (8' MIN. CLEARANCE) (SEE SHEET C12) PROPOSED VERTICAL BRIDGE DEVELOPMENT, LLC 300' GUYED TOWER WITH VERIZON WIRELESS 295' RAD CENTER (305' TO HIGHEST APPURTENANCE) (SEE SHEET C13) TDSGA—PA14 GROUND BAR POST (SEE NOTE 8) PROPOSED VERIZON WIRELESS 3'-4Y2' X 9'-4" 50KW PROPANE GENERATOR ON 8' X 3'-6" CONCRETE PAD (SEE SHEET C6) SITE NOTES: 1. VERTICAL BRIDGE STAFF SHALL COORDINATE WITH THE PROPERTY OWNER AND/OR TOWER OWNER TO OBTAIN THE PROPER EASEMENT AGREEMENTS TO CONSTRUCT AND MAINTAIN EQUIPMENT IN AND AROUND THE TOWER COMPOUND. 2. PROPOSED COMPOUND LAYOUT BASED ON SURVEY PROVIDED BY GEOLINE SURVEYING, INC DATED 02/09/22 AND SITE VISIT ON 5/25/21. 3. CONTRACTOR TO CONFIRM WITH VERIZON CONSTRUCTION MANAGER THAT THE SHELTER/EQUIPMENT SHOWN HAS BEEN ORDERED/SCHEDULED FOR DELIVERY TO THIS SITE. 4. THE BASIS OF EQUIPMENT DESIGN INCLUDES ONE (1) RF CABINET, ONE (1) FUTURE BATTERY CABINET, AND ONE (1) FUTURE EXPANSION CABINET. 5. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING AND MODIFYING SCOPE OF WORK TO ACCOMMODATE ANY CHANGES IN THE EXACT EQUIPMENT PROCURED BY VERIZON WIRELESS. COORDINATE ANY CHANGES WITH VERIZON WIRELESS CONSTRUCTION MANAGER. 6. ROUTE COAX/FIBER UP TOWER PER STRUCTURAL ANALYSIS BY TOWER OWNER. 7. TOWER DIMENSIONS SHOWN ON THIS PLAN ARE FOR TOWER CENTER LOCATION. CONTRACTOR TO OBTAIN COPY OF TOWER ERECTION DRAWINGS FROM VERTICAL BRIDGE CONSTRUCTION MANAGER PRIOR TO DRILLING TOWER FOUNDATIONS. CASSIONS AND TOWER SHOWN ON THIS PLAN ARE ILLUSTRATIVE, SEE DESIGN DRAWING BY OTHERS. DO NOT SCALE. 8. INSTALL 3J" O.D. GALVANIZED STEEL POST FOR TDSGA—PA14 GROUND BAR. POST TO EXTEND 78" ABOVE GRADE AND SHALL BE EMBEDDED IN A 12" 0 CONCRETE FOOTING A MINIMUM OF 36". FOOTING SHALL EXTEND A MINIMUM OF 42" BELOW GRADE. 9. FASTEN PROPANE TANK SUPPORTS USING SIMPSON STRONG —TIE TITEN HD CONCRETE ANCHORS. MINIMUM ANCHOR DIAMETER IS " o, MINIMUM EMBEDMENT IS 2J" AND MINIMUM CLEAR DISTANCE FROM ANCHOR TO EDGE OF CONCRETE IS 2". INSTALL ANCHOR IN STRICT ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS. CONTRACTOR TO NOTIFY ENGINEER PRIOR TO PLACING PAD AND TANK IF THE ANCHOR REQUIREMENTS LISTED ABOVE CANNOT BE ACCOMMODATED DUE TO ACTUAL TANK PROCURED. CONTRACTOR MAY SUBMIT ALTERNATIVE ANCHOR PRODUCT FOR ENGINEER'S APPROVAL. SUBMITTAL SHALL INCLUDE ANCHOR TECHNICAL DATA AND ICC—ES AC193 APPROVAL FOR USE WITH CRACKED CONCRETE. 0 7.5 15 30 GRAPHIC SCALE: 1" = 15' verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley* NORTH PHONE WWW.KIMLEY—HORN.COM FRANKUN STREET, TAMPA, FL 336D2 (813) 620-1460 Horn SURE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tSIl UI,,, O":OESS/0 . "4, 0: SEAL •. :7' 1 047704 : Z . z_ . PROJECT NUMBER. CKHA 140064078 BY: CHECKED BY CDRAWN TDM TWD TITLE. _SHEET SITE PLAN —SHEET NUMBER. C2 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 10' NO SPARK ZONE — RADIUS CENTERED ON FILL VALVE WITH MANUAL SHUT OFF x 2'-3i 7 PROPOSED LESSEE 10' X 4' 3'-4" CONCRETE PAD WITH EQUIPMENT CABINET (SEE SHEET C6) PROPOSED LESSEE 10' H-FRAME W/INTEGRATED LOAD CENTER, DISCONNECT, TELCO BOX, RRU'S AND RAYCAPS 8" 1'-3" 3'-0" 3'-0" 3'-0" e, 7Tl l , 1 GPS MOUNTED ON POST -� PROPOSED LESSEE 19' X 25' WITH 6'-6" X 3'-6" EXTENSION \ GENERATOR EQUIPMENT AREA \ CONDUITS (±497 SQ. FT.) \ (SEE "E" SHEETS) PROPOSED LESSEE 8' X 3'-6" CONCRETE PAD WITH PROPANE TANK (SEE SHEET C5) CONDUITS TO BE STUBBED UP AT GENERATOR STUB UP AREA. EMBED CONDUITS IN CONCRETE PAD AND STUB UP 6" MINIMUM FROM TOP OF PAD. TERMINATE WITH MALE FITTING AND THREADED BUSHING. VOLTAGE STUB -UP AREA (CONTRACTOR TO CONFIRM STUB UP AREAS WITH GENERATOR DELIVERED TO SITE.) EQUIPMENT PAD/ROUTING NOTES: 1. REFER TO THE SITE PLAN FOR EQUIPMENT PAD LOCATION AND ORIENTATION. 2. RUN 2" FLEX TELCO CONDUIT FROM BOTTOM OF TELCO BOX TO SIDE OF RF CABINET WITH CHASE NIPPLE THROUGH FACTORY KNOCKOUT. 3. RUN (2) 2" FLEX POWER CONDUIT AND (1) 1" ALARM CONDUIT FROM BOTTOM OF ILC TO SIDE OF RF CABINET WITH CHASE NIPPLES THROUGH FACTORY KNOCKOUTS. 4. RUN 2" FLEX FIBER CONDUIT FROM BOTTOM OF OVP TO SIDE OF RF CABINET WITH CHASE NIPPLE THROUGH FACTORY KNOCKOUT. 5. RUN (1) 1}c FLEX POWER CONDUIT FOR EVERY (6) RRU CIRCUITS FROM BOTTOM OF OVP TO SIDE OF RF CABINET WITH CHASE NIPPLE THROUGH FACTORY KNOCKOUT. 6. SUPPORT FLEX CONDUIT ON HORIZONTAL H-FRAME RAILS OR ON VERTICAL SITE STRUT SNT10 RAILS ADDED TO H-FRAME FOR CONDUIT/CABLE MANAGEMENT. • 1 RAYCAP'S (TYP.) 117 RRU'S (TYP.) • TDSGA (TYP.) 3"(SEE "E" SHEETS) 5'-4" INSTALL LIGHT FIXTURES ON 60" LONG P1001A UNISTRUT RAIL WAVEGUIDE POST FOUNDATION (TYP.) HYBRID FIBER CABLES (TYP.) 6'-2" NN PROPOSED VERIZON WIRELESS 3'-4Y2" X 9'-4" 50KW PROPANE GENERATOR • 2'-0" EQUIPMENT PAD LAYOUT SCALE: 1 " = 3' IWAVEGUIDE BRIDGE PROPOSED VERIZON WIRELESS 3'-432" X 9'-4" 50KW PROPANE GENERATOR ON 8' X 3'-6" CONCRETE PAD (SEE SHEET C6) f 1 • 7'-6" 7. RUN HYBRID CABLE FOR TOWER MOUNTED RRU'S OVERHEAD ON TRAPEZE SUSPENDED FROM WAVE GUIDE BRIDGE. SWEEP DOWN ONTO H-FRAME RAILS, THEN LOOP UNDER OVP AND CONNECT TO BOTTOM OF OVP. ATTACH GROUND KITS TO HYBRID CABLE BEFORE LOOPING UNDER OVP, AND BOND TO TDSGA GROUND BAR AT BASE OF H-FRAME. 8. RUN COAX CABLE FOR GROUND MOUNTED RRU'S (IF USED) OVERHEAD ON TRAPEZE SUSPENDED FROM WAVE GUIDE BRIDGE. TERMINATE COAX ON ICE BRIDGE AND TRANSITION TO JUMPERS JUST BEFORE REACHING H-FRAME. ATTACH GROUND KITS TO COAX CABLE ON TOWER SIDE OF LAST ICE BRIDGE POST AND BOND TO TDSGA GROUND BAR NEAR TOP OF POST. 9. GPS ANTENNA TO BE MOUNTED TO STANDARD HEIGHT POST WITH EXTENDED MOUNTING PIPE, USING COMMSCOPE GPS-U MOUNTING KIT. MOUNT AS NEAR AS PRACTICAL TO RBA84 CABINET. 10. BOLT CABINETS AND GENERATOR TO SLAB USING FASTENERS SPECIFIED BY EQUIPMENT MANUFACTURER IN FACTORY PROVIDED MOUNTING HOLES. 0 1.5 3 6 GRAPHIC SCALE: 1" = 3' vertic la b idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PREPARED BY: _PLANS 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tS,l UI,s, ,.xN CARo '. o::oESS/0%'71, 0, SEAL •• 1 047704 : Z .z_• .�. .,**. :NE; ,; * PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET EQUIPMENT PAD LAYOUT —SHEET NUMBER. C3 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 KEY NOTES - CONDUIT, CONDUCTORS, & MISC 0 0 O 0 O O 0 0 0 GALVANIZED RIGID STEEL CAP, TYPICAL. ICE BRIDGE, SEE CIVIL SHEETS FOR ADDITIONAL DETAILS. 3" GALVANIZED RIGID STEEL PIPE, TYPICAL. 1548" X 157(3" GALVANIZED STEEL CHANNEL (UNISTRUT #P1000) WITH PLASTIC END CAP (UNISTRUT #P2860), TYPICAL. 1" PVC CONDUIT FOR ROUTING POWER CONDUCTORS TO LIGHTS/DUPLEX OUTLET. ONE (1) #2 AWG BARE SOLID TINNED COPPER BONDING CONDUCTOR (BC) FROM H—FRAME VERTICAL PIPE TO GROUND RING, EXOTHERMIC WELD BOTH ENDS. 1" PVC CONDUIT FOR ROUTING GENERATOR CONTROL AND ALARM SIGNAL CABLES TO THE GENERATOR. 2" PVC CONDUIT FOR ROUTING POWER CONDUCTORS TO THE GENERATOR. 1" PVC CONDUIT FOR ROUTING POWER CONDUCTORS TO THE GENERATOR BATTERY CHARGER AND THE GENERATOR BLOCK HEATER. TWO (2) 2" PVC TELCO CONDUITS, WITH TWO (2) PULL ROPES EACH. 2" FLEX CONDUIT FOR TELCO CABLES TO RF CABINET. REFER TO ROUTING NOTES ON EQUIPMENT PAD LAYOUT. (2) 2" PVC CONDUIT FOR ROUTING POWER CONDUCTORS TO RF CABINET. REFER TO ROUTING NOTES ON EQUIPMENT PAD LAYOUT. 1" PVC CONDUIT FROM INTEGRATED LOAD CENTER (ILC) TO RF CABINET FOR ALARM SIGNAL CABLE. REFER TO ROUTING NOTES ON EQUIPMENT PAD LAYOUT. 2" PVC CONDUIT FOR ROUTING POWER CONDUCTORS FROM THE DISCONNECT SWITCH TO THE UTILITY BREAKER IN THE ILC. 3/4" PVC CONDUIT WITH ONE (1) — #2 AWG BARE TINNED COPPER FROM GROUNDING LUG IN ILC TO GROUND ROD, EXOTHERMIC WELD TO GROUND ROD. 3/4" PVC CONDUIT WITH ONE (1) — #2 AWG BARE TINNED COPPER FROM GROUNDING LUG IN DISCONNECT SWITCH TO GROUND RING, EXOTHERMIC WELD TO GROUND RING. 2" PVC CONDUIT FOR ROUTING POWER CONDUCTORS FROM THE UTILITY COMPANY METER TO THE DISCONNECT SWITCH. 1" PVC CONDUIT FOR ROUTING POWER CONDUCTORS TO AREA LIGHTS. GROUND RING (SEE "E" SHEETS). GROUND ROD, EXOTHERMIC WELD TO GROUND RING (SEE "E" SHEETS). 6" OF #57 STONE MIN. CONCRETE FOUNDATION FOR H—FRAME VERTICAL PIPE. CONCRETE SHALL HAVE A 28 DAY COMPRESSIVE STRENGTH OF 4,000 PSI. AND INCLUDE FIBERMESH 650. WB—K210—B15 HORSEHEAD SUPPORT BRACKET (SEE "WAVEGUIDE BRIDGE DETAILS" SHEET). THRU BOLTS REQUIRED FOR ATTACHMENT IN LIEU OF FACTORY PROVIDED U—BOLTS. INSTALL LIGHT FIXTURES ON 60" LONG P1001A UNISTRUT RAIL (SEE "EQUIPMENT PAD LAYOUT" SHEET). ATTACH P1001A TO H—FRAME POST USING TWO (2) UB3 UNISTRUT CLAMPS. LIGHTS TO BE INSTALLED 7'-6" ABOVE GRADE. 1" PVC CONDUIT FOR ROUTING POWER CONDUCTORS FROM THE ILC TO THE EMERGENCY GENERATOR STOP SWITCH. KEY NOTES - ELECTRICAL EQUIPMENT 0 NEMA 3R ENCLOSURE TELCO BOX WITH REMOVABLE FRONT PANEL, PVC, (18" X 18" X 6" NOMINAL). 0 0 0 0 0 20 AMP GFCI DUPLEX RECEPTACLE AND TIMER SWITCH, ENERLITES HET06 SERIES (OR APPROVED EQUIVALENT) IN LOCKABLE NEMA 3R ENCLOSURE, 2 GANG BOX WITH RED DOT 2CKPM—W COVER. 200 AMP, 120/240 VOLT, INTEGRATED LOAD CENTER WITH 42 SPACE PANEL AND AUTOMATIC TRANSFER SWITCH (30" X 60" X 10" NOMINAL). SE RATED, 240 V, 200 AMP, 2—POLE, NON —FUSED DISCONNECT IN NEMA 3R ENCLOSURE. CIENA ETHERNET IF REQUIRED (COORDINATE WITH VERIZON CONSTRUCTION MANAGER FOR ADDITIONAL CONDUIT AND WIRING REQUIREMENTS. DIPLEXERS "AS NEEDED". VERIZON RF CABINET —REAR VIEW. EMERGENCY SHUTOFF SWITCH FOR GENERATOR MOUNTED ON 4" X 7" GALVANIZED J—BOX COVER PLATE co 10'-0" 3'-0" (TYP.) 00 0000 0000000<tch— o Disconnect Switch 10'-0" Ciena Box FINISH GRADE Telco Box 18"x18"x6" (NOMINAL) 15"x30"x9" (NOMINAL) / / / / / �� /\/\�/\/\�\\ NOTE: FOR CLARITY PURPOSES, THE FRONT ELEVATION OF THE "H" FRAME ONLY SHOWS EQUIPMENT AND CONDUIT ASSOCIATED WITH THE FRONT SIDE. SEE REAR SHEET FOR DETAILS ASSOCIATED WITH EQUIPMENT AND CONDUIT MOUNTED ON THE REAR SIDE OF THE "H" FRAME. Integrated Load Center with Automatic Transfer Switch 30"x60"x10" (NOMINAL) WELL COMPACTED FILL MATERIAL (18" MINIMUM) EQUIPMENT RACK DETAILS - FRONT NOT TO SCALE vertic la idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 —PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 :REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM —LICENSER. ,,%*tS,l UI,s, . ^ �.eeee..• . < / '.0 ox"..• SS/p�.•2 0: SEAL •. 1 047704 : Z .,4/ ••eee.e•• O .,**. :N E ; ,; ** PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET EQUIPMENT RACK DETAIL - FRONT —SHEET NUMBER. C4 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 3'-0" (TYP.) 1>; s= p0000002_ — J0 0 op000popoo 000000000000000 000000000000000000000 0000000 10'-0" op=0=0=0oC o po0o0oC o po0o0oC opo0o0o0oC EQUIPMENT RACK DETAILS - REAR NOT TO SCALE 0 0 0 0 0 R 0 0 0 0 0 moo moo 6" OF #57 STONE MIN. WELL COMPACTED FILL MATERIAL (18" MINIMUM) FINISH GRADE KEY NOTES - CONDUIT, CONDUCTORS, & MISC O O O GALVANIZED RIGID STEEL CAP, TYPICAL. ICE BRIDGE, SEE CIVIL SHEETS FOR ADDITIONAL DETAILS. 3" GALVANIZED RIGID STEEL PIPE, TYPICAL. 1 " X 136" GALVANIZED STEEL CHANNEL (UNISTRUT #P1000) WITH PLASTIC END CAP (UNISTRUT #P2860), TYPICAL. WB—K210—B15 HORSEHEAD SUPPORT BRACKET (SEE "WAVEGUIDE BRIDGE DETAILS" SHEET). THRU BOLTS REQUIRED FOR ATTACHMENT IN LIEU OF FACTORY PROVIDED U—BOLTS. ICE BRIDGE RUNNING TOWARDS TOWER (SEE "EQUIPMENT PAD LAYOUT" SHEET). COAX JUMPER CABLES INTO BOTTOM OF RRU'S, TYPICAL. HYBRID CABLES RUNNING INTO BOTTOM OF RAYCAPS, TYPICAL (SEE NOTE 7 ON "EQUIPMENT PAD LAYOUT" SHEET). 1Y2" POWER FLEX CONDUIT RUNNING FROM BOTTOM OF RAYCAPS TO CABINET, TYPICAL (SEE "EQUIPMENT PAD LAYOUT" SHEET). 2" FIBER FLEX CONDUIT RUNNING FROM BOTTOM OF RAYCAPS TO CABINET, TYPICAL (SEE "EQUIPMENT PAD LAYOUT" SHEET). FIBER/POWER JUMPER TO RRU (TYP. FOR EACH RRU). KEY NOTES - ELECTRICAL EQUIPMENT O O O VERIZON RF RRU'S (MODEL, QUANTITY OF, AND CONFIGURATION DETERMINED BY RF DESIGN). VERIZON RAYCAPS (MODEL, QUANTITY OF, AND CONFIGURATION DETERMINED BY RF DESIGN). VERIZON RF CABINET —FRONT VIEW. FUTURE VERIZON RAYCAPS. NOTE: FOR CLARITY PURPOSES, THE REAR ELEVATION OF THE "H" FRAME ONLY SHOWS EQUIPMENT AND CONDUIT ASSOCIATED WITH THE REAR SIDE. SEE FRONT SHEET FOR DETAILS ASSOCIATED WITH EQUIPMENT AND CONDUIT MOUNTED ON THE FRONT SIDE OF THE "H" FRAME vertic la b idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 :REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,.xN CARS '. O": of ESS/p. �'� •: SEAL •• :37 1 047704 : Z .,•.. :N E ; ,; ** PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET EQUIPMENT RACK DETAIL - REAR —SHEET NUMBER. C5 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 CONCRETE PAD SCHEDULE PAD TYPE "L" "W" "D" REINFORCEMENT EQUIPMENT PAD 10'-0" 4'-0" 6" SEE DETAIL 2/C6 GENERATOR PAD 8'-0" 3'-6" 6" SEE DETAIL 2/C6 PROPANE TANK PAD 8'-0" 3'-6" 6" SEE DETAIL 2/C6 FINISH GRADE #57 STONE MATCH EXISTING DEPTH WITHIN COMPOUND CONCRETE PAD PLAN NOT TO SCALE "SEE PLAN" MEDIUM BROOM FINISH, FINISH TO BE LEVEL ±) " /\ /\//A� WELL COMPACTED FILL MATERIAL (18" MINIMUM) \\\\ \\\UILD UP BACKFILL 2" IN AREA OF SLAB 6" THICK CONCRETE SLAB WITH FIBERMESH 650 CONCRETE PAD FOUNDATION SECTION NOT TO SCALE vertic la idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER ,,%*tS,l UI,s, O�:ofESS/0••'� •: SEAL •• :7' 1 047704 : Z *� ••eee.e•• O PROJECT NUMBER. CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET CONCRETE PAD FOUNDATION DETAILS —SHEET NUMBER. C6 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 FENCE NOTES: 1. USE 3,000—PSI CONCRETE, FULLY CONSOLIDATED AROUND THE POST. 2. WHERE THE POST IS SET IN ROCK OR CONCRETE, CORE A HOLE 12" DEEP AND 1" LARGER IN DIAMETER THAN THE POST. SET THE POST AND GROUT IN PLACE USING NON —SHRINK GROUT. ALL POSTS MUST BE PLUMB AND ALIGNED WITH ONE ANOTHER IN BOTH HORIZONTAL AND VERTICAL PLANES. CORNERS AND GATEPOSTS FOR CHAIN LINK FENCES SHALL EXTEND ABOVE THE TOP STRAND OF BARBED WIRE TO PROVIDE TENSIONING FOR THE BARBED WIRE. PROVIDE MIDRAILS AND BRACING AT ALL CORNER POSTS WHERE THE FENCE CHANGES DIRECTION BY MORE THAN 30 DEGREES. THE GRADE OF THE SITE AND INSTALLATION OF THE FENCE SHALL PROVIDE FOR NO MORE THAN A 1" GAP BETWEEN THE BOTTOM OF THE FENCE MATERIAL AND FINISH GRADE. CONTRACTOR SHALL PROVIDE HOLD OPEN DEVICES FOR ALL GATES AT THE SPECIFIED OPEN POSITIONS, DRIVEN PIPE TYPE RECEIVERS ARE NOT AUTHORIZED. CONTRACTOR SHALL ALSO PROVIDE A MUSHROOM TYPE RECEIVER AT THE CLOSE POSITION. " STEEL TRUSS ROD AND TRUSS ROD TIGHTENER AT ALL CORNERS (TYP.) PROPOSED' GATE STOP HOLDER (TYP OF 2) INSTALL MUSHROOM STOP WITH SLOT PARALLEL TO CLOSED GATES 3 STRANDS OF 12 GA. GALV. BARBED WIRE WITH 4—POINT BARBS CONTRACTOR TO PROVIDE STYMIE LOCK OR APPROVED EQUIVALENT COMMERCIAL FABRICATED 1.90" 0.D. GATE FRAME 10" (TYP.) 6" OF #57 STONE (TO LIMIT OF DISTURBANCE) MIRAFI 500X (TO LIMIT OF DISTURBANCE) COMPACT SUBGRADE AND SURFACING TO PRODUCE AN UNYIELDING SURFACE 3—WIRE 45° BARBED WIRE ARM W/ 3—STRANDS OF BARBED WIRE (TYP.) This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. 27/8" 0.D. STANDARD GALV. CORNER AND GATE POST STEEL GALV. TENSION BAR 15/6" 0.D. STANDARD GALV. RAIL AND BRACE PIPE (TYP.) 7 GA. GALV. TENSION WIRE TENSION / BRACE BAND (TYP.) FINISH GRADE CHAIN LINK FENCE FABRIC LINE POST 8'-0" 0.C. MAX. vertic la idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER ,,%*tS,l UI,s, O�: of _SS/0 • •� 0: SEAL •• • :7' 1 047704 : Z PROJECT NUMBER. CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET FENCE, GATE, AND COMPOUND DETAILS —SHEET NUMBER C7 Copyright Kimley—Hom and Associates, Inc., 2022 NOTE: CURRENT DESIGN ANTICIPATES APPROXIMATELY 8,631t SQ. FT. (0.2 ACRES) OF CLEARING AND GRADING FOR THE PROPOSED PROJECT. IF ADDITIONAL CLEARING IS REQUIRED BEYOND WHAT IS SHOWN IN THE PLANS THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND/OR PROJECT MANAGER. IF DURING THE BID WALK OR CONSTRUCTION IT IS DETERMINED THAT MORE THAN (1) ACRE OF LAND IS TO BE DISTURBED FOR CONSTRUCTION AN EROSION AND SEDIMENTATION CONTROL PLAN MUST BE FILED 30 DAYS PRIOR TO CONSTRUCTION. GRADING NOTES: 1. THE CONTRACTOR SHALL CLEAR AND GRUB THE SITE AND PLACE, COMPACT, AND MOISTURE CONDITION ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEERS SPECIFICATIONS. FILL MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. 2. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. 3. CONTRACTOR SHALL BLEND EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. 4. PORTIONS OF THE SITE NOT SPECIFICALLY MENTIONED WITHIN THE GEOTECHNICAL REPORT SHALL BE COMPACTED TO 95 PERCENT OF THE MATERIALS MAXIMUM DRY DENSITY WITHIN 3 PERCENT OF OPTIMUM MOISTURE CONTENT. 5. FILL SHALL BE PLACED IN MAXIMUM 8 INCH LOOSE LIFTS. 6. UNDISTURBED AREAS WITHIN 30' INGRESS/EGRESS EASEMENT NOT NEEDED FOR UTILITY ROUTING TO BE LEFT UNDISTURBED. 7. GROUND WATER SHOULD BE REASONABLY EXPECTED. ANY DE —WATERING OR MOISTURE CONDITIONING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHOULD BE INCLUDED IN THE CONTRACT PRICE. 8. SEED ALL DISTURBED AREAS NOT TOPPED WITH GRAVEL PER SEEDING SCHEDULE ON DETAIL ON SHEET C9. 9. MAXIMUM CUT SLOPE = 2H:1V UNLESS OTHERWISE NOTED. 10. MAXIMUM FILL SLOPE = 3H:1V UNLESS OTHERWISE NOTED. LEGEND EXISTING CONTOURS PROPOSED CONTOURS LOD/SILT FENCE — — LOD TPF TPF TPF EXISTING SPOT ELEVATION x XXX PROPOSED SPOT ELEVATION • XXX 4-4 i 4-17 i i 4-17 Cut/Fill Summary Name Cut Factor Fill Factor 2d Area Cut Fill Net X - zEG vs FG 1.00 1.15 0.47acres 28.25 Cu. Yd. 255.34 Cu. Yd. 227.10 Cu. Yd.AFill> Totals 0.47acres 28.25 Cu. Yd. 255.34 Cu. Yd. 227.10 Cu. Yd.AFill> eez Em i 7\ \ / (69.25 J6a � 61 66 " 65 211775r--- \ WA_PFO WETLAND AREA 765 ME) 68.00 ME) 455 i du du AG dm PROPOSED VERTICAL BRIDGE 28.5' LF OF CLASS V 18" RCP INV. N: = 62.75' INV. S: = 62.65' 4, 4, IIIIIIIIIIII'4' Ih1Iiii 11 W Clan 65.25) i de- 7-43 66.54 ME AREA OF LOD THAT IMPACTS WETLAND 4,466t SQ. FT. (0.10 ACRES) AREA OF STREAM LOCATED WITHIN LOD THAT IMPACTS WETLAND 180t SQ. FT. (0.004 ACRES) / / 7 Gm / / 6'. / / 7 / GRADING & EROSION CONTROL PLAN SCALE: 1" = 50' 0 25 i 50 i 100 GRAPHIC SCALE: 1" = 50' 3NI-1HO±VW m m co 2 m m n co verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley» NORTH PHONE WWW.KIMLEY-HORN.COM FRANKUN STREET, TAMPA, FL 336D2 (813) 620-1460 Horn SURE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tSIl UI,,, ♦.4N CARS '. O":oESS/p�••� 0: SEAL •• 37 1 047704 : Z • ,0� ••eee.e•• O PROJECT NUMBER. CKHA 140064078 BY: CHECKED BY. CDRAWN TDM TWD TITLE. _SHEET GRADING AND EROSION CONTROL PLAN —SHEET NUMBER. C8 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Hom and Associates, Inc. Copyright Kimley-Hom and Associates, Inc., 2022 NOTE: CURRENT DESIGN ANTICIPATES APPROXIMATELY 8,631± SQ. FT. (0.2 ACRES) OF CLEARING AND GRADING FOR THE PROPOSED PROJECT. IF ADDITIONAL CLEARING IS REQUIRED BEYOND WHAT IS SHOWN IN THE PLANS THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND/OR PROJECT MANAGER. IF DURING THE BID WALK OR CONSTRUCTION IT IS DETERMINED THAT MORE THAN (1) ACRE OF LAND IS TO BE DISTURBED FOR CONSTRUCTION AN EROSION AND SEDIMENTATION CONTROL PLAN MUST BE FILED 30 DAYS PRIOR TO CONSTRUCTION. GRADING NOTES: 1. THE CONTRACTOR SHALL CLEAR AND GRUB THE SITE AND PLACE, COMPACT, AND MOISTURE CONDITION ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEERS SPECIFICATIONS. FILL MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. 2. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. 3. CONTRACTOR SHALL BLEND EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. 4. PORTIONS OF THE SITE NOT SPECIFICALLY MENTIONED WITHIN THE GEOTECHNICAL REPORT SHALL BE COMPACTED TO 95 PERCENT OF THE MATERIALS MAXIMUM DRY DENSITY WITHIN 3 PERCENT OF OPTIMUM MOISTURE CONTENT. 5. FILL SHALL BE PLACED IN MAXIMUM 8 INCH LOOSE LIFTS. 6. UNDISTURBED AREAS WITHIN 30' INGRESS/EGRESS EASEMENT NOT NEEDED FOR UTILITY ROUTING TO BE LEFT UNDISTURBED. 7. GROUND WATER SHOULD BE REASONABLY EXPECTED. ANY DE —WATERING OR MOISTURE CONDITIONING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHOULD BE INCLUDED IN THE CONTRACT PRICE. 8. SEED ALL DISTURBED AREAS NOT TOPPED WITH GRAVEL PER SEEDING SCHEDULE ON DETAIL ON SHEET C9. 9. MAXIMUM CUT SLOPE = 2H:1V UNLESS OTHERWISE NOTED. 10. MAXIMUM FILL SLOPE = 3H:1V UNLESS OTHERWISE NOTED. LEGEND EXISTING CONTOURS PROPOSED CONTOURS LOD/SILT FENCE — — LOD TPF TPF TPF EXISTING SPOT ELEVATION x XXX PROPOSED SPOT ELEVATION • XXX MATCHLINE 001 — 65.36 ME - / WB_PFO WETLAND AREA AREA OF LOD THAT IMPACTS WETLAND 1,281± SQ. FT. (0.03 ACRES) (63.25 ME 63.63 ME) WB_PFO WETLAND AREA AREA OF LOD THAT IMPACTS WETLAND 1,692± SQ. FT. (0.04 ACRES) GRADING & EROSION CONTROL PLAN SCALE: 1" = 50' \-0 NOTE: CURRENT DESIGN ANTICIPATES APPROXIMATELY 8,631± SQ. FT. (0.2 ACRES) OF CLEARING AND GRADING FOR THE PROPOSED PROJECT. IF ADDITIONAL CLEARING IS REQUIRED BEYOND WHAT IS SHOWN IN THE PLANS THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND/OR PROJECT MANAGER. IF DURING THE BID WALK OR CONSTRUCTION IT IS DETERMINED THAT MORE THAN (1) ACRE OF LAND IS TO BE DISTURBED FOR CONSTRUCTION AN EROSION AND SEDIMENTATION CONTROL PLAN MUST BE FILED 30 DAYS PRIOR TO CONSTRUCTION. 0 25 50 100 GRAPHIC SCALE: 1" = 50' 3NI1HO±VVJ Z'80 133HS 33S verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley* NORTH PHONE WWW.KIMLEY—HORN.COM FRANKUN STREET, TAMPA, FL 336D2 (813) 620-1460 Horn SURE 150 :REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM LICENSER• ,,%*tSIl UI,,, ♦.4N CARS '. ♦ ^ e..eeeeee < / �.0 O .O ESS/o�..2 .: ; SEAL •. :77 1 047704 : Z PROJECT NUMBER. CKHA 140064078 BY: CHECKED BY. CDRAWN TDM TWD TITLE. _SHEET GRADING AND EROSION CONTROL PLAN —SHEET NUMBER. C8.1 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 NOTE: CURRENT DESIGN ANTICIPATES APPROXIMATELY 8,631± SQ. FT. (0.2 ACRES) OF CLEARING AND GRADING FOR THE PROPOSED PROJECT. IF ADDITIONAL CLEARING IS REQUIRED BEYOND WHAT IS SHOWN IN THE PLANS THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND/OR PROJECT MANAGER. IF DURING THE BID WALK OR CONSTRUCTION IT IS DETERMINED THAT MORE THAN (1) ACRE OF LAND IS TO BE DISTURBED FOR CONSTRUCTION AN EROSION AND SEDIMENTATION CONTROL PLAN MUST BE FILED 30 DAYS PRIOR TO CONSTRUCTION. GRADING NOTES: 1. THE CONTRACTOR SHALL CLEAR AND GRUB THE SITE AND PLACE, COMPACT, AND MOISTURE CONDITION ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEERS SPECIFICATIONS. FILL MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. 2. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. 3. CONTRACTOR SHALL BLEND EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. 4. PORTIONS OF THE SITE NOT SPECIFICALLY MENTIONED WITHIN THE GEOTECHNICAL REPORT SHALL BE COMPACTED TO 95 PERCENT OF THE MATERIALS MAXIMUM DRY DENSITY WITHIN 3 PERCENT OF OPTIMUM MOISTURE CONTENT. 5. FILL SHALL BE PLACED IN MAXIMUM 8 INCH LOOSE LIFTS. 6. UNDISTURBED AREAS WITHIN 30' INGRESS/EGRESS EASEMENT NOT NEEDED FOR UTILITY ROUTING TO BE LEFT UNDISTURBED. 7. GROUND WATER SHOULD BE REASONABLY EXPECTED. ANY DE -WATERING OR MOISTURE CONDITIONING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHOULD BE INCLUDED IN THE CONTRACT PRICE. 8. SEED ALL DISTURBED AREAS NOT TOPPED WITH GRAVEL PER SEEDING SCHEDULE ON DETAIL ON SHEET C9. 9. MAXIMUM CUT SLOPE = 2H:1V UNLESS OTHERWISE NOTED. 10. MAXIMUM FILL SLOPE = 3H:1V UNLESS OTHERWISE NOTED. LEGEND EXISTING CONTOURS PROPOSED CONTOURS LOD/SILT FENCE — — LOD TPF TPF TPF EXISTING SPOT ELEVATION x XXX PROPOSED SPOT ELEVATION • XXX SEE SHEET C8.1 jj CONSTRUCTION DETAIL (SEE SHEET C10) 0 61 ♦� GRADING & EROSION CONTROL PLAN SCALE: 1" = 50' 0 25 50 100 GRAPHIC SCALE: 1" = 50' verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley* NORTH PHONE WWW.KIMLEY—HORN.COM FRANKUN STREET, TAMPA, FL 336D2 (813) 620-1460 Horn SURE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tSIl UI,,, ♦.4N CARS '. O�:OESS/p..•2 *, SEAL •. :77 1 047704 : Z PROJECT NUMBER' CKHA 140064078 BY: CHECKED BY. CDRAWN TDM TWD TITLE. _SHEET GRADING AND EROSION CONTROL PLAN —SHEET NUMBER. C8.2 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 66 PROPOSED 12' WIDE GRAVEL ACCESS DRIVE 66 64 INV S: 65.50 65.25 PROPOSED GRADE A PROPOSED VERTICAL 28.5' LF OF CLASS INV N:62.75 BRIDGE V 18" RCP 64 • 62 62.65 • EXISTING GRADE 62 60 62.25 ME 60 A -A C8.3 72 SECTION A -A SCALE: 1"=10' H, 1"= 2' V SCALE BASED ON 11"x17" ONLY 72 70 EXISTING GRADE 68 69.98 69.14 69.18 69.14 CL OF SWALE PROPOSED GRADE 70 68 B-B C8.3 SECTION B-B SCALE: 1"=10' H, 1"=2'V SCALE BASED ON 11 "x17" ONLY verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY —PLANS PREPARED BY: 201 Kimley* NORTH PHONE WWW.KIMLEY—HORN.COM FRANKUN STREET, TAMPA, FL 33602 (613) 620-1460 Horn SURE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER ,,%*tS,l UI,�, ♦.�N C A R 0 ..• 0 ••,SS/p�.•2 •• : SEAL •. 7' 1 047704 : Z .off, •........ o . 4. PROJECT NUMBER* CKHA 140064078 BY: CHECKED BY. CDRAWN TDM TWD TITLE. _SHEET GRADING AND EROSION CONTROL PLAN —SHEET NUMBER. C8.3 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 HEIGHT: MAX. 3' MIN. 2' EROSION CONTROL NOTES: EROSION CONTROLS SHALL BE INSTALLED PRIOR TO CONSTRUCTION AND SHALL BE ADEQUATE TO MAINTAIN SEDIMENT ON SITE. 2. ALL EXCAVATED SOILS NOT NEEDED ON SITE FOR BACKFILL OPERATIONS SHALL BECOME PROPERTY OF THE CONTRACTOR AND SHALL BE TAKEN OFF SITE AND LEGALLY DISPOSED OF. 3. SOIL REMAINING ON SITE SHALL HAVE SILT FENCE TIGHTLY PLACED AROUND THE ENTIRE CIRCUMFERENCE OF THE PILE. 4. PROVIDE EROSION CONTROLS AS NECESSARY TO PREVENT EXISTING SOILS FROM DRAINING OFF SITE OR INTO EXISTING DRAINAGE STRUCTURES. 5. ERECTION OF EROSION CONTROLS SHALL BE IN ACCORDANCE WITH STATE AND LOCAL EROSION CONTROL REGULATIONS. u STEEL POSTS MAX. 8' 0.C. WIRE FENCE ("HOG WIRE") FILTER FABRIC BOTTOM OF WIRE FENCE AND FILTER FABRIC BURIED 6" IN EXCAVATED TRENCH SECTION STEEL POST DRIVEN 18" INTO GROUND SEDIMENT FENCE (SILT FENCE) NOT TO SCALE SEEDING SCHEDULE FOR WINTER / SPRING CONSTRUCTION ACTIVITIES SEEDING MIXTURE Species Rate (lb/acre) Rye (grain) 120 Annual lespedeza (Kobe in Piedmont and Coastal Plain, Korean in Mountains) 50 Omit annual lespedeza when duration of temporary cover is not to extend beyond June. SEEDING DATES Mountains-- Above 2500 ft: Below 2500 ft.: Piedmont --Jan. 1 — May 1 Coastal Plain --Dec. 1 — Apr. 15 Feb 15 — May 15 feb. 1 — May 1 SOIL AMENDMENTS Follow recommendations of soil tests or apply 2,000 lb/acre ground agricultural limestone and 750 lb/acre 10-10-10 fertilizer. MULCH Apply 4,000 lb/acre straw. Anchor straw by tacking with asphalt, netting, or a mulch anchoring tool. A disk with blades set nearly straight can be used as a mulch anchoring tool. MAINTENANCE Refertilize if growth is not fully adequate. Reseed, refertilize and mulch immediately following erosion or other damage. WEATHERPROOF SIGN (AS SHOWN ABOVE): SEE NOTES BELOW FOR CONSTRUCTION AND SPACING DATA. 5'—O" 0.C. MAXIMUM SEEDING SCHEDULE FOR SUMMER CONSTRUCTION ACTIVITIES SEEDING MIXTURE Species Rate (lb/acre) Common Bermudagrass 40-80 (1-2 Ib/1,000 sq.ft.) SEEDING DATES Coastal Plain --Apr. 1 — July Piedmont --Apr. 15 — June 30 SOIL AMENDMENTS Apply lime and fertilizer according to soil tests, or apply 3,000 lb/acre ground agricultural limestone and 500 lb/acre 10-10-10 fertilizer. MULCH Use jute, excelsior matting, or other effective channel lining material to cover the bottom of channels and ditches. The lining should extend above the highest calculated depth of flow. On channel side slopes above this height, and in drainages not requiring temporary lining, apply 4,000 lb/acre grain straw and anchor straw by stapling netting over the top. MAINTENANCE A minimum of 3 weeks is required for establishment. Inspect and repair mulch frequently. Refertilize the following Apr. with 50 lb/acre nitrogen. POST MAY BE EITHER 4" DIAMETER PINE, 2" DIAMETER OAK, OR 1.33 Ib/LF STEEL ORANGE, UV RESISTANT, HIGH —TENSILE STRENGTH, POLY BARRICADE FABRIC �■ •• TREEARBOLES PROTECTION —NO AREA ■� ■■■■ DO NOT ENTER ,■■■ m. ■■I ■■■■ ZONA DE PROTECCION '■■■ PARA ■■I ■■■■■■■■■I ■■■■■■■■■ ■■I ■■■■■■■■■I MM..■■I ■■■■■■■■■I MM..MI■■■■■■■■■I M■••■••• SUBGRADE' z NOTES INSTALL TREE PROTECTION FENCE AND SIGNAGE PRIOR TO CALLING FOR SITE INSPECTION. MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF PROJECT. ADDITIONAL SIGNS MAY BE REQUIRED BASED ON ACTUAL FIELD CONDITIONS. TREE PROTECTION FENCE NOT TO SCALE SIGN vertic la idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 :REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER ,,%*tS,l UI,s, ♦.�N CARS '. SEAL •• 7' 1 047704 : Z PROJECT NUMBER. CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET GRADING AND EROSION CONTROL DETAILS —SHEET NUMBER. C9 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 EXISTING ROADWAY 50' MIN., BUT SUFFICIENT TO KEEP SEDIMENT ON SITE 2"-3" STONE TO BE USED (SURGE STONE OR RAILROAD BALLAST) PLAN i 12' OR WIDTH OF PROPOSED STREET, WHICHEVER IS GREATER. NOTES: 1. PUT SILT FENCE OR TREE PROTECTION FENCE UP TO ENSURE CONSTRUCTION ENTRANCE IS USED. 2. IF CONSTRUCTION ON THE SITES ARE SUCH THAT THE MUD IS NOT REMOVED BY THE VEHICLE TRAVELING OVER THE STONE, THEN THE TIRES OF THE VEHICLES MUST BE WASHED BEFORE ENTERING THE PUBLIC ROAD. 3. IF A PROJECT CONTINUES TO PULL MUD AND DEBRIS ON TO THE PUBLIC ROAD, THE GOVERNING AUTHORITY WILL CLEAN THE AREA AND INVOICE THE FINANCIALLY RESPONSIBLE PERSON AS INDICATED ON THE FINANCIAL RESPONSIBILITY FORM. EXISTING ROADWAY 35' MIN. 15' MIN. NEW CONSTRUCTION 6" MIN. l ,I I. 12" MIN. FABRIC UNDER STONE CROSS SECTION CONSTRUCTION ENTRANCE NOT TO SCALE U f 6" BASE OF SURGE STONE OR RAILROAD BALLAST (2" TO 4" 0 STONE TYP.) (SEE NOTE BELOW) 4" OF CRUSHER RUN/ABC STONE. CROWN 2% TO DRAIN GEOTEXTILE FABRIC MIRAFI 500X OR APPROVED EQUAL -111-111� COMPACTED SUBGRADE (95% MAX. DRY DENSITY IN ACCORDANCE WITH ASTM D698) NOTE: IF DETERMINED NECESSARY DURING GRADING AND CONSTRUCTION OF THE ACCESS ROAD BY THE VERIZON WIRELESS PROJECT MANAGER, THE CONTRACTOR SHALL INSTALL 6" BASE OF SURGE STONE OR RAILROAD BALLAST (2" TO 4" 0 STONE TYP.) STANDARD ACCESS ROAD AND TURN -AROUND DETAIL NOT TO SCALE vertic la b idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tS,l UI,s, ♦\.\ CARS ***0 ♦ x �i, O"..• _SS/o.. ,%� • SEAL •. 77 1 047704 : Z • z_ . PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET ACCESS ROAD DETAILS —SHEET NUMBER. C 1 0 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 verticalbri SITE NAME: BLUE PANTHER SITE#: US-NC-5181 FCC TOWER ID #: TO BE LOCATED HERE OWNED BY: VERTICAL BRIDGE TELEPHONE: 877-589-6411 W W W. VERT ICALBRIDGE. COM SALES @ VERTICALBRIDGE. COM OPERATIONS @VERTICALBRIDGE COM NO TRESPASSING VERTICAL BRIDGE - SITE ID SIGN CAUTION Beyond this point: Radio frequency fields at this site may exceed FCC rules for human exposure. For your safety, obey all posted signs and site guidelines for working in radio frequency environments. In accordance with Federal Commurnanons Gommisslon rules on redo M1equeooy emissions 47 CFR 1.1307(h) YELLOW BACKGROUND w/ BLACK LETTERING YELLOW BACKGROUND w/ BLACK LETTERING WHITE BACKGROUND w/ BLACK LETTERING 0 RF EXPOSURE CAUTION SIGN ONOTICED 0 All personnel should have electromagnetic energy (EME) awareness training. © All personnel entering this site must be authorized. © Obey all posted signs. © Assume all antennas are active. Berafonsmittere workirs.ng on antennas. notify owners and disable appropriate Maintain minimum 3 feet clearance from all antennas. © Do not stop in front of antennas. mUse personal RF monitors while working near antennas. © Never operate transmitters without shields during normal operation. Do not operate base station antennas in equipment room. NOTICE-RFE SIGN 12" HIGH X 18" WIDE (OPERATIONS PROVIDED) YELLOW BACKGROUND w/ BLACK LETTERING SIGNAGE NOTES: 1. SIGNS SHALL BE FABRICATED FROM CORROSION RESISTANT PRESSED METAL, AND PAINTED WITH LONG LASTING UV RESISTANT COATINGS. 2. SIGNS (EXCEPT WHERE NOTED OTHERWISE) SHALL BE MOUNTED TO THE TOWER, GATE, AND FENCE USING A MINIMUM OF 9 GAUGE ALUMINUM WIRE, HOG RINGS (AS UTILIZED IN FENCE INSTALLATIONS) OR BRACKETS WHERE NECESSARY. BRACKETS SHALL BE OF SIMILAR METAL AS THE STRUCTURE TO AVOID GALVANIC CORROSION. 3. ADDITIONAL SITE # AND EMERGENCY CONTACT SIGNS SHALL BE MOUNTED AT EACH ACCESS ROAD GATE LEADING TO THE COMPOUND AS WELL AS THE COMPOUND GATE ITSELF. 4. CARRIER SITE # AND EMERGENCY CONTACT SIGNS SHALL BE MOUNTED ON THE EQUIPMENT CABINET W/ PERMANENT SET ADHESIVE. TWO SIDED TAPE SHALL BE UTILIZED AT EACH CORNER ON THE BACKSIDE TO AID PLACEMENT UNTIL ADHESIVE SETS. vertic la b idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 :REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM LICENSER ,,%*tS,l UI,s, ♦.�N CAR° '. O�: of _SS/0 •� 0: SEAL •• as :7' ' 047704 : Z . L : ••e• Nc (N--`-0� J *� •........ O PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET SITE SIGNAGE DETAILS —SHEET NUMBER. C 1 1 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Hon, and Associates, Inc. shall be without liability to Kimley—How and Associates, Inc. Copyright Kimley—How and Associates, Inc., 2022 ow U Z_ cc cc W J 0 U o Z J � z o o� Ise NOTE: SEE DETAIL A 3Y2" O.D. GALVANIZED STD PIPE WITH CAP 1. ALL MATERIALS FURNISHED BY CONTRACTOR UNLESS OTHERWISE NOTED. 3)" O.D. STD GALVANIZED PIPE WITH CAP SUPPORT BRACKET GRATED WAVEGUIDE BRIDGE CHANNEL 0 0 0 0$ 0 0 0 0 0 0 0 030 0 0 0 VERTICAL TRAPEZE SECTION HORIZONTAL CABLE SUPPORT SECTION DETAIL A ANDREW 1 POST WAVEGUIDE BRIDGE KIT (PART #: WB—K210—B15, OR APPROVED EQUIVALENT) WAVEGUIDE BRIDGE DETAIL NOT TO SCALE SEE DETAIL B o W U Z .rcZ cc w w I— J W U 0 o Z. z o 000 Ise NOTE: 3Y2" O.D. GALVANIZED STD PIPE WITH CAP Yz" CROWN GRADE 1'-6" 3Y2" O.D. STD GALVANIZED PIPE WITH CAP 1. ALL MATERIALS FURNISHED BY CONTRACTOR UNLESS OTHERWISE NOTED. 01441 asr 11.=11=11= 11 11=11=1 .11=11=11. FIELD DETERMINE SUPPORT BRACKET _). GRATED WAVEGUIDE BRIDGE CHANNEL as ,F6r 0 0 0 0$ 0 0 0 0 l 0 0 0 0$ 0 0 0 0 l t o 0 0 0 0 0 0 o l VERTICAL TRAPEZE SECTION HORIZONTAL CABLE SUPPORT SECTION DETAIL B ANDREW 2 POST WAVEGUIDE BRIDGE KIT (PART #: WB—K410—B15, OR APPROVED EQUIVALENT) WAVEGUIDE BRIDGE DETAIL (ALT DESIGN - 2 PIPE COLUMNS) NOT TO SCALE vertic la idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PREPARED BY: _PLANS 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER ,,%*tS,l UI,s, 0 •• SS/0% 71, 0: SEAL •. 37 1 047704 : Z PROJECT NUMBER. CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET WAVEGUIDE BRIDGE DETAILS —SHEET NUMBER. C12 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 AZIMUTH 280• (SUB-6) O AZIMUTH 280• (LTE) AZIMUTH/ 280. LTE) 8843, 1 PER SECTOR (TYP. OF 3) -s 0. a , s0. �C)'' 4449, 1 PER SECTOR (TYP. OF 3) PROPOSED GUYED TOWER ANTENNA ORIENTATION PLAN (NOT TO SCALE, FOR ILLUSTRATIVE PURPOSES ONLY, SEE STRUCTURAL ANALYSIS BY OTHERS TO CONFIRM ANTENNA MOUNT TYPE) NOTE: REFER TO RFDS PROVIDED BY VERIZON. CONTRACTOR TO CONTACT THE VERIZON WIRELESS CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION FOR THE CONSTRUCTION RFDS. NOTES: 1. ALL INFORMATION ON THIS PAGE IS PROVIDED BY VERIZON WIRELESS AND/OR OTHERS AND IS SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. CONTRACTOR SHALL CONTACT THE VERIZON WIRELESS CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION FOR ALL DETAILED ANTENNA, AND COAX CABLE INFORMATION. 2. REFER TO STRUCTURAL ANALYSIS BY TOWER OWNER FOR ANALYSIS OF PROPOSED TOWER. 3. IT IS UNDERSTOOD THAT KIMLEY-HORN MAKES NO WARRANTY, EITHER EXPRESSED OR IMPLIED, FINDINGS, DESIGNS, RECOMMENDATIONS, SPECIFICATIONS, OPINION, OR PROFESSIONAL ADVICE RELATING TO THE STRUCTURAL ADEQUACY OF THE PROPOSED TOWER OR ATTACHMENT OF ANTENNAS OR OTHER APPURTENANCES. NOTE: GENERAL CONTRACTOR TO INSTALL RAYCAP OVP, NUMBER AND TYPE PER VERIZON CONSTRUCTION MANAGER. BEACON PER FAA REQUIREMENETS. EXTEND BEACON ABOVE TOP OF ANTENNAS PER VERIZON WIRELESS REQUIREMENTS. TOP OF TOWER EL. 300' A.G.L. PROPOSED 300' GUYED TOWER PROPOSED SIDE MARKER LIGHTS & MOUNTING PLATE PER FAA REQUIREMENTS PROPOSED CHAIN LINK SECURITY FENCE A. EXISTING GRADE (t0' A.G.L.) TOP OF LIGHTNING ROD EL. 310' A.G.L. PROPOSED LESSEE ANTENNAS EL. 295' A.G.L. FUTURE ANTENNAS FUTURE ANTENNAS PROPOSED LESSEE 10' X 4' CONCRETE PAD WITH EQUIPMENT CABINET GUYED TOWER ELEVATION NOT TO SCALE NOTES: 1. ALL PROPOSED ATTACHMENTS TO TOWER BASED ON TOWER DESIGN DRAWINGS BY OTHERS (SEE GENERAL NOTE 1.07, SHEET N1). 2. THE TOWER ELEVATION SHOWN IS FOR REFERENCE ONLY. 3. COAX/FIBER CABLE LENGTHS ARE APPROXIMATE. CONTRACTOR TO VERIFY CORRECT LENGTH IN FIELD AT TIME OF CONSTRUCTION. 4. PROPOSED TOWER WILL BE GALVANIZED STEEL -GRAY IN COLOR. vertic la b idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION• SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• FOR ILLUSTRATIVE PURPOSES ONLY - NO SIGNATURE REQUIRED PROJECT NUMBER. CKHA 140064078 DRAWN BY: CHECKED BY• 1 TDM TWD TITLE. _SHEET ANTENNA AND TOWER ELEVATION DETAILS —SHEET NUMBER. C13 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 4'-0" WIDE MAN GATE *GATE LOCATION SHOWN IS CRITICAL FOR GUY WIRE MAINTENANCE CONCRETE GUY ANCHOR FOUNDATION DESIGN TO BE FINALIZED PENDING RECEIPT OF TOWER DRAWINGS. 6'-0" HIGH CHAIN GUYED TOWER LINK FENCE l SUPPORT CABLES x X —CONCRETE FOUNDATION (DESIGN BY OTHERS) POINT WHERE GUY ANCHOR ENTERS GRADE LEVEL CONCRETE FOUNDATION (DESIGN BY OTHERS) GUY ANCHOR CORNER POSTS CONCRETE FOUNDATION (2000 PSI) GEOTEXTILE FABRIC AT SUB GRADE LINE POSTS FOUNDATION CONCRETE (2000 PSI) EXTENT OF GRAVEL AND FABRIC BOUNDARY (TYPICAL) NEW GRAVEL WITH GEOTEXTILE FABRIC EXTENDED 2'-0" OUTSIDE OF FENCE LINE (C.F.) ?TO CENTER OF TOWER PROVIDE SINGLE RUN OF 6' HIGH CHAIN LINK FENCE. LENGTH AS REQUIRED TO POINT WHERE THERE IS 14' VERTICAL CLEARANCE FROM GUY WIRE TO GRADE "DANGER - KEEP OUT" SIGN TO BE MOUNTED ON GATE OF GUY ANCHOR ENCLOSURE. 0. BARBED WIRE NOT REQUIRED FOR GUY ANCHOR FENCE. This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. vertic la idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER ,,%*tSIl UI,s, 0 ..,SS/p�.2 #: SEAL •. 1 047704 : Z #*� ••eeeee•• O PROJECT NUMBER. CKHA 140064078 DRAWN BY: CHECKED BY* 1 TDM TWD TITLE. _SHEET GUY ANCHOR FENCE DETAIL -SHEET NUMBER. C14 Copyright Kimley—Hom and Associates, Inc., 2022 KEY NOTES - CONDUIT, CONDUCTORS, & MISC 1" SCHEDULE 40 STEEL PIPE. PIPE MATERIAL TO COMPLY WITH SECTION 403.4.2 OF THE 2018 NORTH CAROLINA FUEL GAS CODE. PIPE SIZED FOR AN INLET PRESSURE OF 11" IN W.C.I AND A MAXIMUM LENGTH OF 50 LF. 1" POLYETHYLENE PIPE WITH A TRACER WIRE. PIPE MATERIAL TO COMPLY SECTION 403.6 OF THE 2018 NORTH CAROLINA FUEL GAS CODE. PIPE SIZED FOR INLET PRESSURE OF 11" IN W.C. AND MAXIMUM LENGTH OF 50 LF. TRACER WIRE SHALL COMPLY WITH SECTION 404.17.3 OF 2018 NORTH CAROLINA FUEL GAS CODE. 4" SCHEDULE 80 PVC SLEEVE. CONNECTIONS TO BE MADE WITH FLEXIBLE FITTINGS. LIQUID PROPANE TANK WITH AN INTEGRAL MANUAL SHUTOFF VALVE. SIZE AND TYPE PER VERIZON WIRELESS. TANK SHALL COMPLY WITH ALL REQUIREMENTS OF THE NFPA AND INTERNATIONAL FUEL GAS CODE. O i • ■ 0 KEY NOTES - EQUIPMENT LIQUID PROPANE TANK WITH AN INTEGRAL MANUAL SHUTOFF VALVE. SIZE AND TYPE PER VERIZON WIRELESS. TANK SHALL COMPLY WITH ALL REQUIREMENTS OF THE NFPA AND INTERNATIONAL FUEL GAS CODE. FIRST STAGE REGULATOR PER NFPA 58 SECTION 6.8.1.1. 4" PVC CAP. PROPOSED VALVE, DRIP LEG, SECOND STAGE REGULATOR, AND FLEXIBLE CONNECTORS. ALL MATERIALS SHALL BE INSTALLED PER THE 2018 NORTH CAROLINA FUEL GAS CODE. PROPOSED LP GENERATOR. 0 0 0 D4 ADDITIONAL NOTES 1. UPON COMPLETION OF ASSEMBLY, PIPING SYSTEMS (INCLUDING HOSE) SHALL BE TESTED AND PROVED FREE OF LEAKS IN ACCORDANCE WITH SECTION 406 OF THE 2018 NORTH CAROLINA FUEL GAS CODE. 2. GENERATOR SUPPLY LINE UPSTREAM OF SECOND STAGE REGULATOR SIZED FOR 632 THOUSAND BTU AT 30 FEET MAXIMUM PIPING LENGTH. LINES SIZED PER TABLES 402.4(28) AND 402.4(35) OF THE 2018 NORTH CAROLINA FUEL GAS CODE. IF THE INSTALLATION OF THE SERVICE LINE CANNOT BE MADE WITHIN 30 FEET, THE CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO ORDERING MATERIALS TO RECEIVE DIRECTION. 3. COORDINATE ALL ROUTING WITH OTHER TRADES SHOWN ON CIVIL AND ELECTRICAL DRAWINGS. 4. MINIMUM SEPARATION BETWEEN POINT OF DISCHARGE OF CONTAINER PRESSURE RELIEF VALVE, VENT OF A FIXED MAXIMUM LIQUID LEVEL GAUGE ON A CONTAINER, AND THE CONTAINER FILLING CONNECTION TO EXTERIOR SOURCES SHALL BE NO LESS THAN FIVE FEET TO ANY SPARK SOURCE. NOTE THAT THIS SEPARATION IS DETERMINED BY SECTION 6.26.3 OF THE NFPA AND IS ONLY VALID IF A MANUAL SHUT OFF VALVE IS INSTALLED. • O O 12" MIN MECHANICAL PLAN AND NOTES NOT TO SCALE vertic la b idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tS,l UI,s, ♦.xN CARS '. O": of ESS/p. •2 •: SEAL •• 77 1 047704 : Z .,**. :NE; ,; * PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET MECHANICAL PLAN AND NOTES —SHEET NUMBER. M1 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 ELECTRICAL NOTES 1.00 CODES, STANDARDS, & SPECIFICATIONS 1.01 IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT ALL MATERIALS AND LABOR RELATED DIRECTLY OR INDIRECTLY TO ALL ELECTRICAL WORK DOCUMENTED IN THESE DRAWINGS SHALL BE PROVIDED AND PERFORMED IN CONFORMANCE WITH ALL CURRENT GOVERNING CODES, STANDARDS, AND PROFESSIONAL STANDARD OF CARE TO INCLUDE THE AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM), UNDERWRITERS LABORATORY (UL), NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA), AMERICAN STANDARDS ASSOCIATION (ASA), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), AND THE NATIONAL ELECTRICAL CODE (NEC). 1.02 MATERIALS SHALL BE NEW AND SHALL CONFORM TO ALL APPLICABLE CURRENT GOVERNING STANDARDS ESTABLISHED FOR EACH ITEM BY ASTM, UL, NEMA, ASA, AND NFPA. 1.03 ALL ELECTRICAL WORK SHALL COMPLY WITH ALL APPLICABLE STATE, COUNTY, AND MUNICIPAL CODES AND ORDINANCES, AS WELL AS ALL CURRENT GOVERNING STANDARDS AND PRACTICES AS REQUIRED BY NEC, NEMA, ANSI, NFPA, UBC, UL, IEEE, AND THE LOCAL UTILITY COMPANY. 1.04 ALL ELECTRICAL GROUNDING SHALL COMPLY WITH THE CURRENT EDITION OF THE NEC. 1.05 CONTRACTOR SHALL MAINTAIN UL LISTED FIRE RATINGS AT ALL WALL PENETRATIONS. 1.06 CONTRACTOR SHALL MAINTAIN A MINIMUM CLEARANCE OF 36" IN FRONT OF ALL ELECTRICAL EQUIPMENT AS REQUIRED BY NEC. MINIMUM CLEARANCE SHALL BE OBSERVED FOR BOTH THE FRONT AND THE REAR OF THE METER H-FRAME RACK AND THE EQUIPMENT H-FRAME RACK. 2.00 GENERAL 2.01 CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS AND ASSOCIATED FEES RELATED TO THE PROJECT AND SHALL DELIVER A COPY OF ALL PERMITS TO THE VERIZON REPRESENTATIVE. 2.02 CONTRACTOR SHALL SCHEDULE AND SHOULD ATTEND ALL INSPECTIONS REQUIRED BY THE JURISDICTION HAVING AUTHORITY. 2.03 CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, TOOLS, ACCESSORIES, ETC., FOR A COMPLETE WORKING ELECTRICAL INSTALLATION. 2.04 ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH APPLICABLE BUILDING CODES AND LOCAL ORDINANCES, INSTALLED IN A NEAT MANNER, AND SHALL BE SUBJECT TO APPROVAL BY THE ENGINEER. 2.05 CONTRACTOR SHALL PROTECT ADJACENT EQUIPMENT AND FINISHES FROM DAMAGE AND SHALL REPAIR TO ORIGINAL CONDITION ANY ITEMS DAMAGED AS A RESULT OF THE WORK. 2.06 CONTRACTOR SHALL REPAIR ANY LANDSCAPING DISTURBED DURING CONSTRUCTION. 2.07 IF CONDUIT RUNS HAVE MORE THAN THREE (3) CONSECUTIVE 90 DEGREE TURNS, THE CONTRACTOR SHALL INSTALL PULL BOXES AS REQUIRED BY NEC. 2.08 CONTRACTOR SHALL INDICATE THE LOCATION OF ALL CAPPED UNDERGROUND SPARE CONDUIT ON THE RECORD DRAWINGS SUBMITTED TO THE OWNER. 2.09 CONTRACTOR SHALL COORDINATE EXACT ROUTING OF CONDUIT WITH OWNER. ALL CONDUIT SHALL BE ROUTED WITHIN 3 FEET, EITHER SIDE, OF PERIMETER FENCING. 3.00 MATERIALS 3.01 ALL EQUIPMENT AND MATERIALS SHOWN SHALL BE CONSIDERED NEW UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. 3.02 FINAL CONNECTIONS OF EQUIPMENT SHALL BE PER MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT SUPPLIED BY VERIZON. 3.03 CONTRACTOR SHALL PROVIDE AN UPDATED PANELBOARD DIRECTORY FOR THE PANEL FROM WHICH THE NEW VERIZON EQUIPMENT CIRCUIT WILL BE CONNECTED. CONTRACTOR SHALL SUBMIT UPDATED DIRECTORY IN A PLASTIC COVER TO THE BUILDING OWNER FOR APPROVAL PRIOR TO INSTALLATION. 3.04 CONTRACTOR SHALL FIELD DETERMINE ACTUAL CONDUIT ROUTING AND SHALL OBTAIN APPROVAL FROM THE TOWER OWNER OF THE PROPOSED ROUTING PRIOR TO CONDUIT INSTALLATION. 3.05 ALL CONDUCTORS SHALL BE COPPER WITH THWN INSULATION AND ALL TERMINATIONS SHALL BE RATED FOR AT LEAST 75 DEGREES CELSIUS. 3.06 ALL NEUTRAL CONDUCTORS SHALL HAVE WHITE INSULATION. ALL GROUND CONDUCTORS SHALL HAVE GREEN INSULATION. COLOR TAPE IDENTIFICATION OF THESE CONDUCTORS IS NOT PERMITTED. 3.07 CONTRACTOR SHALL SEAL ALL CONDUITS ENTERING AN ENCLOSURE WITH CONDUIT SEALANT THAT IS COMPATIBLE WITH THE INSULATION OF THE CONDUCTORS IN THE CONDUIT. 3.08 CONDUIT RUNS SHALL HAVE A CONTINUOUS DOWNWARD SLOPE AWAY FROM ALL EQUIPMENT TO PREVENT WATER INFILTRATION. 3.09 ALL CONDUIT SHALL BE SCHEDULE 40 PVC UNLESS NOTED OTHERWISE ON THE PLANS. WHEN CONDUIT IS ROUTED UNDER A ROADWAY, SCHEDULE 80 PVC CONDUIT SHALL BE UTILIZED. MANUFACTURED BEND RADII SHALL BE PER NEC. 3.10 CONTRACTOR SHALL PROVIDE TWO (2) 200 POUND TEST POLYETHYLENE PULL CORDS IN ALL CONDUITS AND ALL INNERDUCTS. PULL CORDS SHALL BE SECURED AT EACH END OF CONDUIT RUNS. ALL SPARE CONDUIT ENDS SHALL BE CAPPED WITH MANUFACTURED PVC FITTINGS. 3.11 CONTRACTOR SHALL BOND EACH METALLIC CONDUIT ENTERING A METALLIC ENCLOSURE WITH A #8 MIN AWG INSULATED COPPER BONDING JUMPER PER NEC. CONTRACTOR SHALL BOND ALL ELECTRICAL EQUIPMENT TO THE H-FRAME RACK ON WHICH EQUIPMENT IS MOUNTED WITH #8 MIN AWG INSULATED COPPER BONDING JUMPERS PER NEC. 3.12 CONTRACTOR SHALL IDENTIFY THE END OF ALL SPARE UNDERGROUND CONDUITS AND PROVIDE AND INSTALL 90 DEGREE ELBOWS WITH VERTICAL CONDUIT EXTENSIONS TO EXTEND 3" ABOVE FINISHED CRUSHED AGGREGATE GRADE. CONTRACTOR SHALL TERMINATE CONDUITS WITH MANUFACTURED CONDUIT CAPS THAT THE CONTRACTOR HAS PAINTED ORANGE. 3.13 CONTRACTOR SHALL PROVIDE AND INSTALL AN ENGRAVED PHENOLIC PLATE ON THE FRONT OF THE INTEGRATED LOAD CENTER. THE WORDING ON THE PLATE SHALL READ AS FOLLOWS: "MAXIMUM DRAW OF ALL RECTIFIERS AND EQUIPMENT ON THE LOAD CENTER CANNOT EXCEED 50kW. IF ADDITIONAL POWER IS REQUIRED, THE EXISTING 50kW GENERATOR MUST BE REPLACED." 4.00 PRE -CONSTRUCTION COORDINATION 4.01 CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND NOTE EXISTING CONDITIONS THAT MIGHT AFFECT THEIR WORK. ALL SUCH CONDITIONS SHALL BE REPORTED TO THE ENGINEER PRIOR TO BID. 4.02 THE CONTRACTOR SHALL PROVIDE A UTILITY LOCATOR AND SHALL VERIFY THE ACTUAL LOCATION OF ALL UTILITIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING UTILITIES. ANY DAMAGE TO EXISTING UTILITIES SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. 4.03 CONTRACTOR SHALL VERIFY, PRIOR TO ROUGH -IN, THAT SITE CONDITIONS ALLOW FOR THE PLACEMENT OF THE ELECTRICAL EQUIPMENT AS SHOWN ON THE PLANS. 4.04 CONTRACTOR SHALL COORDINATE WITH LOCAL ELECTRICAL UTILITY REGARDING THE EXACT LOCATION OF THE TRANSFORMER, ALL METERING REQUIREMENTS, AND CONDUIT ROUTING BETWEEN TRANSFORMER AND METER. 4.05 CONTRACTOR SHALL COORDINATE WITH LOCAL TELCO UTILITY REGARDING THE EXACT LOCATION OF THE TELCO SERVICE ENTRY POINT. 4.06 CONTRACTOR SHALL COORDINATE WITH AUTHORITY HAVING JURISDICTION REGARDING LOCAL FROST LINE REQUIREMENTS FOR RACEWAY MATERIAL SELECTION AND INSTALLATION. 4.07 CONTRACTOR SHALL PERFORM AN ARC FLASH ANALYSIS AT THE INTEGRATED LOAD CENTER AND PROVIDE ARC FLASH LABEL PER NEC. 4.08 ALL CIRCUIT BREAKERS AND EQUIPMENT SHALL HAVE A MINIMUM AIC RATING OF 10,000 AMPS. IF THE RATING OF THE UTILITY TRANSFORMER PROVIDING THE ELECTRICAL SERVICE IS GREATER THAN 75 kVA, THE CONTRACTOR SHALL PERFORM A SHORT CIRCUIT ANALYSIS TO DETERMINE THE REQUIRED AIC RATING FOR THE CIRCUIT BREAKERS AND EQUIPMENT. PRIOR TO PURCHASING EQUIPMENT, THE CONTRACTOR SHALL CONTACT THE ELECTRIC UTILITY AND OBTAIN IN WRITING THE MAXIMUM AVAILABLE FAULT CURRENT (AFC) AT THE UTILITY SERVICE POINT. PROVIDE MAX. AFC SIGNAGE AS REQUIRED PER NEC 110.24. THE CONTRACTOR SHALL ENSURE ALL ELECTRICAL EQUIPMENT, CIRCUIT BREAKERS, DISCONNECTS, FUSES, AND PANELBOARDS HAVE A FAULT CURRENT INTERRUPTING RATING GREATER THAN THE AVAILABLE FAULT CURRENT. verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY-HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: -DATE: -ISSUED FOR: -BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tS I l UI,s, • 0 •• SS/0 . 71, •• : SEAL •, . 040828 : . . '.O.'•:LCINE1-.0•O ',. 'N. � . \A' *♦♦ PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET ELECTRICAL NOTES -SHEET NUMBER. El This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Hom and Associates, Inc. Copyright Kimley-Hom and Associates, Inc., 2022 J Fx — x — x — x —x —x—/ /4%7 \ 1 H i \—x—x—x—x—x—x� PROPOSED 50' X 50' CHAIN LINK FENCED COMPOUND x— x— x— x— x— x— x— x— x— x— x— x— x— x— x— x 49 UTILITY SERVICE ROUTING PLAN SCALE: 1" = 10' PROPOSED 300' GUYED TOWER 0 5 10 20 GRAPHIC SCALE: 1" = 10' KEY NOTES - ELECTRICAL EQUIPMENT • UTILITY METER H—FRAME (SEE DETAIL 1/E4). • POWER STUB UP (SEE NOTE 4.04 ON SHEET El). O3 EXISTING LIT FIBER HANDHOLE/PEDESTAL. (CONTRACTOR TO CONFIRM EXISTENCE AND LOCATION). TRAFFIC RATED TELCO VAULT LABELED "VZW FIBER". • (SEE NOTE 4.05 ON SHEET El) O5 TELCO BOX (SEE SHEET C4). O6 CIENA UNIT, IF NEEDED (SEE SHEET C4). O7 INTEGRATED LOAD CENTER (SEE SHEET C4). O8 VERIZON CONCRETE EQUIPMENT PAD (SEE SHEET C6). O9 VERIZON CONCRETE GENERATOR PAD (SEE SHEET C6). 10 DISCONNECT SWITCH (SEE SHEET C4). 11 HAZARD LIGHTING CONTROL PANEL (SEE SHEET E4.1). 12 VERTICAL BRIDGE BREAKER PANEL 13 PROPANE TANK (SEE SHEET M1). KEY NOTES - CONDUIT, CONDUCTORS, & MISC. A TWO (2) 4" PVC POWER CONDUITS FOR INCOMING SERVICE A LATERALS FROM LOCAL UTILITY (SEE TRENCH DETAIL 2/E7). B 2" PVC POWER CONDUIT FROM PROPOSED METER RACK TO B EQUIPMENT RACK (SEE TRENCH DETAIL 2/E7). C TWO (2) 2" PVC TELCO CONDUITS, WITH TWO (2) PULL ROPES C EACH (SEE TRENCH DETAIL 2/E7). 4" PVC BRIDGE FIBER CONDUIT. (IF NO EXISTING LIT FIBER OD HANDHOLE/PEDESTAL IS PRESENT CONTRACTOR TO PROVIDER A 5' LONG CAPPED STUB BRIDGE CONDUIT). E TWO (2) 2" PVC CONDUITS FROM RIGHT OF WAY W/TWO (2) E PULL ROPES (SEE TRENCH DETAIL 2/E7 AND SHEET E3). F 2" PVC CONDUIT FOR ROUTING POWER CONDUCTOR TO THE F GENERATOR. (SEE TRENCH DETAIL 2/E7). 1" PVC CONDUIT FOR ROUTING GENERATOR CONTROL AND OG ALARM SIGNAL CABLES TO THE GENERATOR (SEE TRENCH DETAIL 2/E7). 1" PVC CONDUIT FOR ROUTING POWER CONDUCTOR TO THE OH GENERATOR BATTERY CHARGER AND THE GENERATOR BLOCK HEATER (SEE TRENCH DETAIL 2/E7). O 1" PVC POWER CONDUIT FROM PROPOSED HAZARD LIGHTING CONTROL PANEL ON METER RACK TO TOWER LIGHTING. OK PROPANE SERVICE LINE (SEE SHEET M1). NOTES: GENERAL CONTRACTOR IS TO CONFIRM WITH VERIZON CONSTRUCTION MANAGER WHETHER INSTALLATION OF THE TWO (2) 2" CONDUITS TO THE RIGHT OF WAY WILL BE PART OF THE INITIAL CONSTRUCTION. verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley* NORTH PHONE WWW.KIMLEY—HORN.COM FRANKUN STREET, TAMPA, FL 336D2 (813) 620-1460 Horn SURE 150 :REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM LICENSER. • 0 •• _SS/p�••2• 0: SEAL •• . 040828 : . .. :O ••.tiC1NEF:.••p : 0',',. '• N. c . \)',♦♦ PROJECT NUMBER' CKHA 140064078 BY: CHECKED BY. CDRAWN TDM TWD TITLE. _SHEET UTILITY SERVICE ROUTING PLAN —SHEET NUMBER. E2 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 / // ` . - vertic la bridge / \ 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 , \ TEL. (561) 948-6367 / 0 / \ O OyA =PROJECT INFORMATION: ,/ \ SITE NAME: c' BLUE PANTHER � SITE No.: US-NC-5181 "7, �4 PROJECT#: 140064078 \ 6720NC210HW� HARRELLS, NC 28444 © ., O BLADEN COUNTY \ • yd..% =PLANS PREPARED BY: WEI \ ,. Kimle »>Horn /' �� O C - y 201 NORTH FRANKLIN STREET, SUITE 150 \ TAMPA, FL 33602 / PHONE (813) 620-1460 \ 0-'' _e —0WWW.KIMLEY—HORN.COM � e 2 \ © �,' j \11) \ :��'• O ` 0 # ALIC \ „--- • --..---,:l.' ....... E0 \ ,,,,,;;;;;;"" ©/ . \ .........7.' ' =REV:=DATE:—ISSUED FOR—BY:= • \ �/ / POWER NOTES: 8 • — — _� 1. CONTRACTOR TO CONTACT ANTHONY RAYNOR 7 a (ANTHONYRAYNOR@FOURCTY.ORG) (910) 6 m `\ 872-7107, PRIOR TO CONSTRUCTION. 5 o © 2. FOUR COUNTY ELECTRIC MEMBERSHIP 4 CORPORATION TO RUN PRIMARY/SECONDARY / CONDUCTOR OVERHEAD TO PROPOSED UTILITY 2 07/20/22 CONSTRUCTION TDM / POLE TRANSFORMER PAD AT ENTRANCE TO / 1 06/29/22 CONSTRUCTION TDM / SITE/OUTSIDE OF FENCE. 0 05/31/22 FOR REVIEW TDM „ 3. CONTRACTOR TO INSTALL CONDUIT FROM METER =LICENSER: RACK TO PAD—MOUNTED TRANSFORMER. ed O OVERALL UTILITY SERVICE ROUTING PLAN LOCATION OF PAD MOUNTED TRANSFORMER TO ,,, CAAFo7'♦ BE COORDINATED WITH FOUR COUNTY ELECTRIC CA/� w MEMBERSHIP CORPORATION PRIOR TO ��� e.•••••.e 0 CONSTRUCTION. FOUR COUNTY ELECTRIC =��;•FESS/�•.•�iG♦� N EI SCALE: 1" = 100' MEMBERSHIP CORPORATION TO PULL SECONDARY ;�- ti9 ;y . CONDUCTORS THROUGH CONTRACTOR INSTALLED :Q KEY NOTES - ELECTRICAL EQUIPMENT KEY NOTES -CONDUIT, CONDUCTORS, & MISC. CONDUIT AND MAKE SERVICE CONNECTIONS. .• SEAL • 040828 • 4. POWER COMPANY TO OBTAIN ANY ADDITIONAL •TWO (2) 2" PVC CONDUIT FOR "VZW FIBER" WITH TWO (2) PULL .C� • F` . o O1 EXISTING LIT FIBER HANDHOLE/PEDESTAL, IF PRESENT. EASEMENTS. � "••NG I NEB ' � ROPES. (SEE DETAIL 2/E6); (APPROXIMATELY 1,077± LF); GENERAL ♦� TRAFFIC RATED TELCO VAULT LABELED "VZW FIBER". (SPACED EVERY O CONTRACTOR TO CONFIRM NEED FOR CONDUITS TO RIGHT OF WAY 5. NO COST ESTIMATE IS AVAILABLE AT THIS TIME. ♦♦#� P`•�� m ® 500', AT MAJOR TRANSITIONS, AND AS NEEDED TO ALLOW DARK AND HANDHOLE AT RIGHT OF WAY WITH VERIZON CONSTRUCTION CONTRACTOR TO CONTACT ANTHONY RAYNOR TO ♦♦♦�N N,��� N FIBER TO BE PULLED) (SEE NOTE 4.05 ON SHEET El) MANAGER. CONFIRM FINAL COST BEFORE TIME OF �������� Z PROPOSED UTILITY POLE FURNISHED AND INSTALLED BY FOUR 4" PVC BRIDGE FIBER CONDUIT. (IF NO EXISTING LIT FIBER CONSTRUCTION. [DRAWN KHA PROJECT NUMBER: COUNTY ELECTRIC MEMBERSHIP CORPORATION (FOUR COUNTY EMC). ® HANDHOLE/PEDESTAL IS PRESENT CONTRACTOR TO PROVIDER A 5' 140064078 LOCATION OF UTILITY POLE TO BE CONFIRMED PRIOR TO LONG CAPPED STUB BRIDGE CONDUIT). CONSTRUCTION. BY. CHECKED BY. EXISTING ONE FIBER HANDHOLE (CONTRACTOR TO CONFIRM EXISTENCE O 4" PVC BRIDGE FIBER CONDUIT. (IF NO EXISTING ONE FIBER TDM TWD ea O AND LOCATION HANDHOLE IS PRESENT, BRIDGE CONDUIT WILL BE BY OTHER) o ) A —SHEET TITLE: FOUR COUNTY EMC TO FURNISH AND INSTALL PRIMARY CONDUCTOR PROPOSED PAD—MOUNTED TRANSFORMER FURNISHED AND INSTALLED O OVERHEAD FROM EXISTING UTILITY POLE TO PROPOSED UTILITY POLE. NORTH ® BY FOUR COUNTY EMC. LOCATION OF TRANSFORMER TO BE l OVERALL UTILITY a CONFIRMED PRIOR TO CONSTRUCTION. o FOUR COUNTY EMC TO FURNISH AND INSTALL PRIMARY CONDUCTOR ROUTING PLAN N 6 EXISTING UTILITY POLE FURNISHED AND INSTALLED BY FOUR COUNTY ® UNDERGROUND FROM PROPOSED UTILITY POLE TO PROPOSED EMC. PAD—MOUNTED TRANSFORMER. 0 50 100 200 FOUR COUNTY EMC TO FURNISH AND INSTALL PRIMARY CONDUCTOR rSHE ET NUMBER: I AND CONDUIT UNDERGROUND FROM PROPOSED PAD—MOUNTED GRAPHIC SCALE: 1" = 100' •i TRANSFORMER TO METER. E3 This document,together with the concepts and designs presented herein,as an instrument of service,is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates,Inc.shall be without liability to IGmley—Hom and Associates,Inc. Copyright IOmley—Hom and Associates,Inc.,2022 KEY NOTES - ELECTRICAL EQUIPMENT 0 N' 7 EXISTING LIT FIBER HANDHOLE/PEDESTAL, IF PRESENT. TRAFFIC RATED TELCO VAULT LABELED "VZW FIBER". (SPACED EVERY 500', AT MAJOR TRANSITIONS, AND AS NEEDED TO ALLOW DARK FIBER TO BE PULLED) (SEE NOTE 4.05 ON SHEET El) PROPOSED UTILITY POLE FURNISHED AND INSTALLED BY FOUR COUNTY ELECTRIC MEMBERSHIP CORPORATION (FOUR COUNTY EMC). LOCATION OF UTILITY POLE TO BE CONFIRMED PRIOR TO CONSTRUCTION. EXISTING ONE FIBER HANDHOLE (CONTRACTOR TO CONFIRM EXISTENCE AND LOCATION). PROPOSED PAD -MOUNTED TRANSFORMER FURNISHED AND INSTALLED BY FOUR COUNTY EMC. LOCATION OF TRANSFORMER TO BE CONFIRMED PRIOR TO CONSTRUCTION. EXISTING UTILITY POLE FURNISHED AND INSTALLED BY FOUR COUNTY EMC. • LIGE \I/ OVERALL UTILITY SERVICE ROUTING PLAN FO SCALE: 1" = 15' KEY NOTES - CONDUIT, CONDUCTORS, & MISC. TWO (2) 2" PVC CONDUIT FOR "VZW FIBER" WITH TWO (2) PULL ROPES. (SEE DETAIL 2/E6); (APPROXIMATELY 1,126± LF); GENERAL O CONTRACTOR TO CONFIRM NEED FOR CONDUITS TO RIGHT OF WAY AND HANDHOLE AT RIGHT OF WAY WITH VERIZON CONSTRUCTION MANAGER. 4" PVC BRIDGE FIBER CONDUIT. (IF NO EXISTING LIT FIBER ® HANDHOLE/PEDESTAL IS PRESENT CONTRACTOR TO PROVIDER A 5' LONG CAPPED STUB BRIDGE CONDUIT). O4" PVC BRIDGE FIBER CONDUIT. (IF NO EXISTING ONE FIBER HANDHOLE IS PRESENT, BRIDGE CONDUIT WILL BE BY OTHER) OFOUR COUNTY EMC TO FURNISH AND INSTALL PRIMARY CONDUCTOR OVERHEAD FROM EXISTING UTILITY POLE TO PROPOSED UTILITY POLE. FOUR COUNTY EMC TO FURNISH AND INSTALL PRIMARY CONDUCTOR OE UNDERGROUND FROM PROPOSED UTILITY POLE TO PROPOSED PAD -MOUNTED TRANSFORMER. FOUR COUNTY EMC TO FURNISH AND INSTALL PRIMARY CONDUCTOR OF AND CONDUIT UNDERGROUND FROM PROPOSED PAD -MOUNTED TRANSFORMER TO METER. LIGE FO \ I / POWER NOTES: 1. CONTRACTOR TO CONTACT ANTHONY RAYNOR (ANTHONYRAYNOR©FOURCTY.ORG) (910) 872-7107, PRIOR TO CONSTRUCTION. 2. FOUR COUNTY ELECTRIC MEMBERSHIP CORPORATION TO RUN PRIMARY/SECONDARY CONDUCTOR OVERHEAD TO PROPOSED UTILITY POLE/TRANSFORMER PAD AT ENTRANCE TO SITE/OUTSIDE OF FENCE. 3. CONTRACTOR TO INSTALL CONDUIT FROM METER RACK TO PAD -MOUNTED TRANSFORMER. LOCATION OF PAD -MOUNTED TRANSFORMER TO BE COORDINATED WITH FOUR COUNTY ELECTRIC MEMBERSHIP CORPORATION PRIOR TO CONSTRUCTION. FOUR COUNTY ELECTRIC MEMBERSHIP CORPORATION TO PULL SECONDARY CONDUCTORS THROUGH CONTRACTOR INSTALLED CONDUIT AND MAKE SERVICE CONNECTIONS. 4. POWER COMPANY TO OBTAIN ANY ADDITIONAL EASEMENTS. —L5. NO COST ESTIMATE IS AVAILABLE AT THIS TIME. CONTRACTOR TO CONTACT ANTHONY RAYNOR TO CONFIRM FINAL COST BEFORE TIME OF CONSTRUCTION. FO 0 7.5 FO \ NORTH 15 30 GRAPHIC SCALE: 1" = 15' verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley* NORTH PHONE WWW.KIMLEY—HORN.COM FRANKUN STREET, TAMPA, FL 336D2 (813) 620-1460 Horn SURE 150 :REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM LICENSER. • O�:oESS/p�•'2 0: SEAL •• • 040828 : . .• ',. 'N. � . \)',,♦ PROJECT NUMBER' CKHA 140064078 BY: CHECKED BY. CDRAWN TDM TWD TITLE. _SHEET ENLARGED UTILITY ROUTING PLAN -SHEET NUMBER. E3.1 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 8'-0" to • O 14 / 8'-0" Tenant Meters O 0 0 \/ \/\ 44 /\/\\\ \\/\/ 6" OF #57 STONE MIN. WELL COMPACTED FILL MATERIAL (18" MINIMUM) \// /\ / \\\\\\ .\\\\\\/ 1'-6" METER RACK DETAILS - FRONT NOT TO SCALE FINISH GRADE KEY NOTES - CONDUIT, CONDUCTORS, & MISC GALVANIZED RIGID STEEL CAP, TYPICAL. 3" GALVANIZED RIGID STEEL PIPE, TYPICAL. 1%" x 1%" GALVANIZED STEEL CHANNEL (UNISTRUT #P1000 OR APPROVED EQUIVALENT) WITH PLASTIC END CAP (UNISTRUT #P2860), TYPICAL. ONE (1) #2 AWG BARE SOLID TINNED COPPER BONDING CONDUCTORS (BC) FROM H—FRAME VERTICAL PIPE TO GROUND RING, EXOTHERMIC WELD BOTH ENDS. 4" PVC CONDUIT FOR INCOMING SERVICE LATERALS FROM LOCAL UTILITY, TYPICAL OF 2. KEYNOTE NOT USED. 2" PVC CONDUIT FOR ROUTING FEEDERS TO NON —FUSED DISCONNECT SWITCH. %" PVC CONDUIT WITH ONE (1) — 2/0 BARE STRANDED TINNED COPPER GROUNDING ELECTRODE CONDUCTOR (GEC) FROM GROUNDING LUG TO GROUND ROD, EXOTHERMIC WELD GEC TO GROUND ROD. GROUND RING (SEE "E" SHEETS). GROUND ROD, EXOTHERMIC WELD TO GROUND RING. (SEE "E" SHEETS). CONCRETE FOUNDATION FOR H—FRAME VERTICAL PIPE. CONCRETE SHALL HAVE A 28 DAY COMPRESSIVE STRENGTH OF 4,000 PSI. AND INCLUDE FIBERMESH 650-3E. KEY NOTES - ELECTRICAL EQUIPMENT 200 AMP METER SOCKET IN NEMA 3R ENCLOSURE, TYPICAL OF 4. ONLY TOP SOCKET WILL RECEIVE METER UNDER THIS CONTRACT. 800 AMP, 22KAIC, 4 GANG, SERVICE ENTRANCE RATED METER CENTER IN NEMA 3R ENCLOSURE. BOND TO RACK PER NEC. 200 AMP, 2 POLE (22KAIC) DISCONNECT CIRCUIT BREAKER FOR TOP METER ONLY. CONTRACTOR SHALL MOUNT THE METER CENTER SUCH THAT THE TOP CIRCUIT BREAKER IS NO MORE THAN 6' ABOVE GRADE. verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY -PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM LICENSER *01,, ....1••• • 0 •• SS/o�••�': SEAL •• • 040828 : • • • e PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET METER RACK DETAILS - FRONT -SHEET NUMBER. E4 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 8'-0" O 0=0=0 8'-0" 00000000000000000000000000000000000000pop 0pop 00000 l000000 0000000000 0000000000 000000opo O 00000 000000opopo 1 1'-6" no /\/ HAZARD LIGHTING CONTROL PANEL o=O()0o0o0= LGT PANEL 0=0=00 01=0=0=0=0=0=0=0=0=0o° =,=000000 \\opnr \%\i / NOTE: FOR CLARITY PURPOSES, THE REAR ELEVATION OF THE "H" FRAME ONLY SHOWS EQUIPMENT AND CONDUIT ASSOCIATED WITH THE REAR SIDE. SEE SHEET E4 FOR DETAILS ASSOCIATED WITH EQUIPMENT AND CONDUIT MOUNTED ON THE FRONT SIDE OF THE "H" FRAME. METER RACK DETAILS - REAR NOT TO SCALE KEY NOTES - CONDUIT, CONDUCTORS, & MISC GALVANIZED RIGID STEEL CAP, TYPICAL. 3" GALVANIZED RIGID STEEL PIPE, TYPICAL. 1%" x 15/s GALVANIZED STEEL CHANNEL (UNISTRUT #P1000 OR APPROVED EQUIVALENT) WITH PLASTIC END CAP (UNISTRUT #P2860), TYPICAL. ONE (1) #2 AWG BARE SOLID TINNED COPPER BONDING CONDUCTORS (BC) FROM H-FRAME VERTICAL PIPE TO GROUND RING, EXOTHERMIC WELD BOTH ENDS. 1Y2" PVC POWER CONDUIT FROM METER. FLASH HEAD CABLE. 2Y2" FLASH HEAD CABLE PROTECTION CONDUIT (MIN. 18" BELOW GRADE). GROUND RING (SEE SHEETS E6 & E7). GROUND ROD, EXOTHERMIC WELD TO GROUND RING. (SEE DETAIL 2/E7). CONCRETE FOUNDATION FOR H-FRAME VERTICAL PIPE. CONCRETE SHALL HAVE A 28 DAY COMPRESSIVE STRENGTH OF 4,000 PSI. AND INCLUDE FIBERMESH 650-3E. 3/4." PVC WITH ONE (1) - #2 AWG BARE TINNED COPPER GROUNDING ELECTRODE CONDUCTOR (GEC) FROM GROUNDING LUG TO GROUND ROD, EXOTHERMIC WELD GEC TO GROUND ROD. 1" PVC CONDUIT FROM LGT PANEL. 1/6" PVC CONDUIT FOR ROUTING POWER CONDUCTORS TO GFCI RECEPTACLE. 1" PVC CONDUIT FOR TELCOM LINK.. KEY NOTES - ELECTRICAL EQUIPMENT 1 HAZARD LIGHTING CONTROL PANEL (FLASH TECHNOLOGY FTS 370D OR APPROVED EQUIVALENT) IN NEMA 4X ENCLOSURE. O 120/240V, 100A MCB SERVICE ENTRANCE RATED PANEL IN NEMA 3R ENCLOSURE. O ONE (1) 20A DUPLEX GFCI WALL PLUG WITH WEATHER RATED COVER. O4 WIRELESS ANTENNA MOUNTED TO H-FRAME POST. verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 :REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• *01,, ....1••• • O�: oESS/p�•'� ,: SEAL •• • 040828 : : '.O•'•:LCINE1-.0•O e PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET METER RACK DETAILS - REAR -SHEET NUMBER. E4.1 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 • Meter Socket Meter Socket , Meter Socket , Meter Socket , 2P-200A 22KAIC G N 0 0 0 • 0 0 RF CABINET • • 0 • 0 0 0 0 0 0 0 0 -u 0 0 0 D -U 0 00 0 DQ IMF IMF 1P-20A 0 0 • o 0 2P-20A 1P-20A 0 0 • 0 0 2P-20A 1P-20A 2P-20A • 2P-2 A 2P-20A • 2P-2 A 2P-20A • 2P-2 A 0 0 • o 2P-20A 2P-20A o 0 2P-20A 2P-20A 01P-20A 0 • 0 0 0 ©IcIDijJ�\ Area Lighting Fixtures • 0 Battery Charger Block Heater Control Module Generator J 0 REQUIRED SIGNAGE PER NEC 702 AT SERVICE DISCONNECT "WARNING: Shock hazard exists if grounding electrode conductor or bonding jumper connection in this equipment is removed while alternate source(s) is energized. Opening the equipment disconnect will cause the stand-by generator to start. To remove power entirely from the equipment, the generator must be turned OFF using emergency stop switch." REQUIRED SIGNAGE PER NEC 702 AT SERVICE DISCONNECT & INTEGRATED LOAD CENTER "NOTE: Emergency power is supplied by a stand-by generator located behind Verizon equipment rack." ELECTRICAL SINGLE LINE DIAGRAM NOT TO SCALE KEY NOTES - CONDUIT, CONDUCTORS, & MISC O TWO (2) 4" CONDUITS BY CONTRACTOR FOR INCOMING SERVICE LATERALS BY LOCAL UTILITY FOR 800 AMP, 120/240 VOLT SINGLE PHASE SERVICE. BOND GROUND BUS TO NEUTRAL BUS AND GROUND BUS TO ENCLOSURE WITH 2/0 BONDING JUMPERS. ONE (1) 2/0 BARE STRANDED TINNED COPPER GEC TO GROUND ROD, EXOTHERMIC WELD GEC TO GROUND ROD. THREE (3) 3/0 CONDUCTORS AND ONE (1) #6 AWG GROUND IN 2" CONDUIT. TWO (2) #12 AWG CONDUCTORS AND ONE (1) #12 AWG GROUND IN 1" CONDUIT. ONE (1) #2 BARE TINNED COPPER FROM GROUNDING LUG IN ILC TO GROUND ROD, EXOTHERMIC WELD TO GROUND ROD. AUTOMATIC TRANSFER SWITCH ALARM AND GENERATOR CONTROL CABLES IN 1" CONDUIT. FOUR (4) #12 CONDUCTORS AND ONE (1) #12 AWG GROUND IN 1" CONDUIT. THE GENERATOR, WHEN UTILIZING A TWO POLE ATS WITH A SOLID NEUTRAL, IS NOT A SEPARATELY DERIVED SYSTEM. THEREFORE, DO NOT BOND THE NEUTRAL TO THE GROUND AT THE GENERATOR. TWELVE (12) #10 AWG THHN CONDUCTORS AND THREE (3) #10 AWG EG IN 2" PVC CONDUIT. ALARM CABLES IN 1" PVC CONDUIT. ONE (1) — #2 BARE TINNED COPPER FROM GROUNDING LUG IN DISCONNECT SWITCH TO GROUND RING, EXOTHERMIC WELD TO GROUND RING. THREE (3) 3/0 AWG CONDUCTORS AND ONE (1) #4 AWG EG IN 2" CONDUIT. VERIFY GENERATOR BREAKER DOES NOT EXCEED 200 AMPS. 1" PVC CONDUIT FOR ROUTING POWER CONDUCTORS FROM THE ILC TO THE EMERGENCY GENERATOR STOP SWITCH. TWELVE (12) #10 AWG THHN CONDUCTORS AND THREE (3) #10 AWG. FOR RECTIFIERS AND TWO (2) #10 THHN CONDUCTORS AND ONE (1) #10 AWG FOR CABINET MOUNTED GFI OUTLET, ALL IN ONE 2" PVC CONDUIT. KEY NOTES - ELECTRICAL EQUIPMENT FURNISH AND INSTALL 800 AMP, 3—WIRE, SINGLE PHASE, 120/240 VOLT, 22KAIC, FOUR —SPACE MULTI —GANG METER CENTER WITH 200 AMP RATED METER SOCKETS IN NEMA 3R ENCLOSURE, SE RATED. CONTRACTOR SHALL FURNISH AND INSTALL 200 AMP CIRCUIT BREAKER AT METER BASE IF NOT ALREADY EXISTING. 20 AMP GFCI DUPLEX OUTLET RECEPTACLE AND TIMER SWITCH, ENERLITES HET06 SERIES (OR APPROVED EQUIVALENT) IN LOCKABLE NEMA 3R ENCLOSURE. FURNISH AND INSTALL SE RATED 240 V, 200 AMP, 2 POLE, NON —FUSED DISCONNECT IN NEMA 3R ENCLOSURE. 200 AMP, 120/240 VOLT, ILC WITH 42 SPACE PANEL AND AUTOMATIC TRANSFER SWITCH. ALL CIRCUIT BREAKERS SHALL BE RATED 10KAIC MINIMUM. ILC IS FURNISHED BY VZW AND INSTALLED BY GENERAL CONTRACTOR. FURNISH AND INSTALL TWO (2) AREA LIGHTS, (LITHONIA HFR-250M—TA120—DNA—LP1), (OR APPROVED EQUIVALENT). 50 KW DIESEL GENERATOR, CONTRACTOR SHALL COORDINATE SPECIFIC GENERATOR CONFIGURATION WITH OWNER AND INSTALL THE GENERATOR IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. GENERATOR BREAKER SIZED AND PROVIDED BY GENERATOR MANUFACTURER. EMERGENCY GENERATOR STOP SWITCH IN NEMA 3R ENCLOSURE WILL BE FURNISHED BY VERIZON AND INSTALLED BY GC. vertic la b idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 :REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM —LICENSER. ,,%*tS,. UI,s, • O�:oESS/p�•'2 •: •SEAL •. . 040828 : • ',. 'N. c . \A' *♦♦ PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET ELECTRICAL SINGLE LINE DIAGRAM —SHEET NUMBER. E5 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 0 ) 2P-100A 0 O 1P-20A � o 1 P-20A • GFCI PLUG O • O O HAZARD LIGHTING CONTROL PANEL ELECTRICAL SINGLE LINE DIAGRAM 5.1 NOT TO SCALE KEY NOTES - CONDUIT, CONDUCTORS, & MISC 4" CONDUITS BY CONTRACTOR FOR INCOMING SERVICE LATERALS BY LOCAL UTILITY FOR FOUR (4) — 200 AMP (22KAIC), 120/240 VOLT SINGLE PHASE SERVICES. CONTRACTOR SHALL COORDINATE QUANTITY OF CONDUITS REQUIRED WITH LOCAL UTILITY. BOND GROUND BUS TO NEUTRAL BUS AND BOND GROUND BUS TO ENCLOSURE WITH 3/0 BONDING JUMPERS. 2/0 GROUND ELECTRODE CONDUCTOR, BOND TO GROUND ROD VIA EXOTHERMIC WELD. THREE (3) #10 AWG CONDUCTORS AND ONE (1) #10 AWG EGC IN 1/6" PVC CONDUIT. THREE (3) #2 AWG CONDUCTORS AND ONE (1) #8 AWG EGC IN 1i " PVC CONDUIT. ONE (1) — #2 AWG BARE TINNED COPPER GROUNDING ELECTRODE CONDUCTOR (GEC) FROM GROUNDING LUG TO GROUND ROD, EXOTHERMIC WELD GEC TO GROUND ROD. TWO (2) #12 AWG CONDUCTORS AND ONE (1) #12 AWG GROUND IN 1" CONDUIT. SEE SHEET E5 FOR VERIZON SINGLE LINE & PANEL SCHEDULE. 1" PVC CONDUIT FOR TELCOM LINK. KEY NOTES - ELECTRICAL EQUIPMENT FURNISH AND INSTALL SERVICE ENTRANCE RATED GANGED METER CENTER WITH FOUR (4) — 200 AMP, 120/240 VOLT SINGLE PHASE SERVICE POSITIONS IN NEMA 3R ENCLOSURE. COORDINATE SPECIFIC REQUIREMENTS WITH LOCAL UTILITY. HAZARD LIGHTING CONTROL PANEL IN NEMA 4X ENCLOSURE. 120/240 VOLT, 100 AMP MCB PANEL 'LTG' IN NEMA 3R ENCLOSURE 20A GFCI DUPLEX WALL PLUG WITH WEATHER RATED COVER. WIRELESS ANTENNA MOUNTED TO H—FRAME POST. LTG PANEL Voltage: 240/120Volts MCB Size: 100 Amps Phase, Wires: Single Phase, 3 Wire AIC Rating: 10,000Amps min Mounting Type: Surface Bus Rating: 100 Amps Enclosure Type: NEMA 3R Neurta Rating: 100% Load Served Load kVA) A 8 Circuit Bkr Size Ckt Nbr Phase Ckt Nbr Circuit Bkr Size Load kVA) A B — Load Served A I B HAZARD LIGHTING 1.92 1P-20 1 * 2 SPACE GFCI PLUG 0.18 1P-20 3 * 4 SPACE SPACE 5 * 6 SPACE SPACE 7 * 8 SPACE Sub -Total (kVA) 1.92 0.18 0.00 0.00 Sub -Total (kVA) Total Connected (kVA) kVA Amps kVA LOAD SUMMARY A B 1.92 0.18 2.10 Load Description Connected Load kVA) A B Demand Factor Demand Load (kVA) A B RECTIFIERS/EQUIPMENT 1.25 0.00 0.00 LIGHTING 1.92 1.25 2.40 0.00 DUPLEX RECEPTACLES 0,18 1.00 0.00 0.18 TOTAL MISCELLANEOUS 1.25 0.00 0.00 Total Power per Phase Total Demand Current per Phase Iota) Demand Power 2.40 0.18 20.00 1.50 2.58 vertic la idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION - SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 :REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tS,. UI,s, z 0 �•• _SS/0,••• 71•, ,i SEAL •. . 040828 : • • . ***B'N. �:.\A'*♦♦ PROJECT NUMBER* CKHA 140064078 DRAWN BY: CHECKED BY: 1 TDM TWD TITLE. _SHEET ELECTRICAL SINGLE LINE DIAGRAM —SHEET NUMBER. E5.1 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 PANEL SCHEDULE - VERIZON INTEGRATED LOAD CENTER Voltage 240/120 Volts MCB Size 200 Amps Phase, Wires Single Phase, 3 Wire AIC Rating 10,000 Amps min Mounting Type Surface Bus Rating 200 Amps Enclosure Type NEMA 3R Neutral Rating 100% Load (kVA) Circuit Ckt Nbr Phase A B Ckt Nbr Circuit Load (kVA) Load Served A B BkrSize BkrSize A B Load Served RECTIFIER 1 1.78 1 � 2 1P-20 0.58 AREA LIGHTS/GFCI 1.78 2P-20 3 4 1P-20 1.50 GEN BLOCK HEATER _0 in RECTIFIER 2 1.78 5 6 1P-20 0.30 GEN BATTERY CHARGER 1.78 2P-20 7 8 ---- 0.00 SPACE 11 RECTIFIER 3 1.78 9 10 1P= 20 0.18 CAB DUPLEX OUTLET : I.._ 1.78 2P-20 11 12 0.00 SPACE RECTIFIER 4 1.78 13 14 2P-20 1.78 1.78 RECTIFIER 9 16 1.78 2P-20 15 U 0_ RECTIFIER 5 1.78 17 18 2P-20 1.78 1.78 RECTIFIER 10 _0 - . 1. 0_ ._ 20 1.78 2P-20 19 RECTIFIER 6 1.78 1.78 2P-20 21 22 2P-20 0.00 0.00 RECTIFIER 11 (SPARE) . 0_ 24 23 • RECTIFIER 7 1.78 1.78 2P-20 25 26 2P-20 0.00 0.00 RECTIFIER 12 (SPARE) _ . 28 27 : RECTIFIER 8 1.78 1.78 2P-20 29 30 ---- 0.00 SPACE 31 32 0.00 SPACE 1134 SPACE 0.00 ---- 33 ---- 0.00 SPACE SPACE 0.00 35 36 0.00 SPACE : SPACE 0.00 ---- 37 38 ---- 0.00 SPACE TVSS 0.00 39 40 0.00 SPACE _0 (INTERNAL TO ILC) 0.00 2P-30 41 42 ---- 0.00 SPACE _0 Sub -Total (kVA) 14.24 14.24 4.62 5.06 Sub -Total (kVA) A B 18.86 19.30 LOAD SUMMARY 38.16 Total Connected (kVA) Load Description Connected Load (kVA) A B Demand Factor Demand Load (kVA) A B RECTIFIERS/EQUIP 17.80 17.80 1.00 17.80 17.80 LARGEST MOTOR 0.00 0.00 1.00 0.00 0.00 ALL OTHER MOTORS 0.00 0.00 1.00 0.00 0.00 LIGHTING 0.40 0.00 1.25 0.50 0.00 DUPLEX RECEPTACLES 0.36 0.00 1.00 0.36 0.00 TOTAL MISCELLANEOUS 0.30 1.50 1.00 0.30 1.50 Total Power per Phase 18.96 19.30 kVA Total Demand Current per Phase 158.00 161.00 Amps Total Demand Power 38.26 kVA *NOTE: CIRCUIT LOAD AND DEMAND FACTOR PROVIDED BY VERIZON. PANEL SCHEDULE NOT TO SCALE verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY-HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: -DATE: -ISSUED FOR: -BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM LICENSER ,,%*tS I l UI,s, • 0 •• SS/0 . 71, •• : •SEAL •, . 040828 : . . '. O .'•: LC I NE-1-.0 O ',. 'N. � . \A' *,♦ PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET PANEL SCHEDULE -SHEET NUMBER. E6 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Hom and Associates, Inc. Copyright Kimley-Hom and Associates, Inc., 2022 GUYED TOWER TOP OF GRAVEL GUYED TOWER FOUNDATION 410 COAX CABLE. COAX GROUNDING KIT. COAX DRIP LOOP. ICE BRIDGE. TOWER BOTTOM GROUND BAR (TDSGA—PA14) "// 4 11\_EXOTHERMIC WELD GROUNDING CONDUCTORS TO GROUND RING, TYPICAL. TOWER GROUND RING // DRIP LOOP DETAIL NOT TO SCALE e.� N 0 0 CDC6CDC6CDC6CDC60 f VARIES f 11 11 III III IIIII III �IllliI IIIIII1 6" 1 12" 1 6" 24" IIP FINISHED GRADE. CRUSHED AGGREGATE, SEE CIVIL DRAWINGS FOR DETAILS. COMPACTED BACKFILL. 6" WIDE METALLIC UTILITY WARNING TAPE. IDEAL INDUSTRIES #42-251 OR APPROVED EQUIVALENT. UNDERGROUND CONDUITS, SEE PLANS FOR SIZE & QUANTITY. NOTES: 1. IF GROUND SURFACE IS OTHER THAN NEWLY GRAVELED AREA. CONTRACTOR IS TO RESTORE TO ORIGINAL CONDITION. 2. PROVIDE PVC CONDUIT BELOW GRADE EXCEPT AS NOTED BELOW. 3. PROVIDE SCHEDULE 40 OR SCHEDULE 80 PVC CONDUIT & ELBOWS AT STUB UP LOCATIONS (I.E. POLES, EQUIPMENT, ETC.) 4. PROVIDE SCHEDULE 80 PVC CONDUIT BELOW PARKING LOTS AND ROADWAYS. TYPICAL TRENCH DETAIL NOT TO SCALE verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• • 0 .• SS/0 . 71, 0: SEAL •. . 040828 : • . ',. 'N. � . \A' *,♦ PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET ELECTRICAL DETAILS —SHEET NUMBER. E7 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 GROUNDING NOTES 1. THE GROUND RING SHALL CONSIST OF #2 AWG BARE SOLID TINNED COPPER (STC) CONDUCTOR, UNLESS NOTED OTHERWISE, BURIED AT 30" BELOW FINISHED GRADE (OR BELOW FROST LINE). LOCATE 24" MINIMUM AND 36" MAXIMUM FROM EQUIPMENT AREA AND FROM TOWER FOUNDATION. ALL CONNECTIONS SHALL BE MADE USING A PARALLEL TYPE EXOTHERMIC WELD, UNLESS NOTED OTHERWISE. 2. INSTALL GROUND RODS AS SHOWN AND AS REQUIRED. GROUND RODS TO BE COPPER CLAD STEEL, 5/8" DIAMETER AND 10FT IN LENGTH. SPACING BETWEEN GROUND RODS SHALL BE 10FT MINIMUM AND 15FT MAXIMUM. TOP OF GROUND ROD TO BE 30" MINIMUM BELOW GRADE (OR BELOW FROST LINE). BOND TOP OF GROUND ROD TO GROUND WIRE WITH EXOTHERMIC WELD. DO NOT EXOTHERMICALLY WELD ANYTHING TO GROUND ROD EXCEPT GROUND WIRE WHICH PASSES OVER TOP OF GROUND ROD (CLAMPED CONNECTIONS TO GROUND ROD PER TOWER MANUFACTURERS DETAILS ARE ACCEPTABLE). 3. EQUIPMENT GROUND RING SHALL HAVE A MINIMUM OF 4 GROUND RODS, INSTALLED AT THE CORNERS OF THE GROUND RING PLUS ADDITIONAL RODS AS REQUIRED TO COMPLY WITH THE SPACING REQUIREMENTS. TOWER GROUND RING SHALL HAVE A MINIMUM OF 3 GROUND RODS, EXCEPT USE 4 RODS AT A MONOPOLE TOWER. WHERE SPREAD TOWER FOOTING WOULD PREVENT GROUND RODS FROM BEING DRIVEN INTO SOIL ADJACENT TO TOWER, PROVIDE VERTICAL 1" DIAMETER PVC SLEEVES EMBEDDED IN FOOTING TO ALLOW INSTALLATION OF GROUND RODS. 4. EQUIPMENT GROUND RING AND TOWER GROUND RING SHALL BE BONDED TOGETHER WITH TWO #2 STC GROUND LEADS, TYPICALLY ONE ON EACH SIDE OF ICE BRIDGE. 5. BOND TOWER TO TOWER GROUND RING AT THREE LOCATIONS WITH #2 STC GROUND LEAD. SELF SUPPORT TOWERS SHALL HAVE EACH LEG BONDED TO GROUND RING, MONOPOLES AND GUYED TOWERS SHALL HAVE GROUND LEADS EQUALLY SPACED AROUND TOWER. EXOTHERMICALLY WELD GROUND LEADS TO TOP OF BASE PLATES, OR ATTACH TO TOWER USING TOWER MANUFACTURER PROVIDED DETAIL. 6. PROVIDE #2 STC RADIALS FROM THE TOWER GROUND RING TO EACH FENCE CORNER POST. RADIALS SHALL HAVE GROUND RODS AS PER THE REQUIRED SPACING. THE GROUND ROD AT THE END OF EACH RADIAL SHALL BE 24" MAXIMUM FROM FENCE CORNER POST. EQUIPMENT AREA GROUND RING AND CONNECTING GROUND LEADS [BETWEEN EQUIPMENT AREA AND TOWER GROUND RINGS] MAY BE USED AS PART OF THE RADIAL GOING TO THE FENCE CORNER POST CLOSEST TO THE EQUIPMENT AREA. 7. MINIMUM BEND RADIUS FOR #2 AWG GROUND WIRE IS 12", EXCEPT USE 24" FOR TOWER GROUND RINGS AND EQUIPMENT PAD GROUND RINGS. 8. GROUND ALL EXTERIOR EXPOSED METAL OBJECTS. USE TWO HOLE LUGS FOR CONNECTION TO FLAT METAL SURFACES. USE ONLY STAINLESS STEEL HARDWARE ON ALL MECHANICAL CONNECTIONS. CLEAN ALL SURFACES (AND STRIP PAINTED SURFACES) TO BARE BRIGHT METAL PRIOR TO MAKING GROUND CONNECTIONS. APPLY ANTI —OXIDE COMPOUND TO ALL CONNECTIONS. APPLY ZINC RICH PAINT (COLD GALV.) TO ALL EXOTHERMIC WELDS, AND TO ANY METAL EXPOSED BY CLEANING, STRIPPING, GRINDING, CUTTING OR DRILLING. 9. ALL GROUNDING CONDUCTORS ABOVE GRADE SHALL BE RUN IN 3/4" FLEXIBLE PVC CONDUIT. CONDUIT SHALL BEGIN WITHIN 3/4" OF ABOVE GROUND CONNECTION POINT, SHALL EXTEND 24" BELOW GRADE MINIMUM, AND SHALL BE FILLED WITH SEALANT AT ABOVE GROUND CONNECTION POINT. SECURE CONDUIT EVERY 24" ON VERTICAL RUNS AND EVERY 36" ELSEWHERE WITH NON—METALLIC TIES. 10A. AT GUYED AND SELF SUPPORT TOWERS MOUNT TDSGA—PA14 TOWER BOTTOM GROUND BAR ON DEDICATED POST DIRECTLY BELOW COAX CABLES COMING OFF TOWER. POST TO BE 3.5" OD GALVANIZED SCHEDULE 40 PIPE WITH GALVANIZED PIPE CAP. TOP OF POST TO BE 78" ABOVE GRADE. EMBED POST 30" MINIMUM IN 12" DIAMETER BY 36" DEEP MINIMUM CONCRETE FOOTING WITH TOP OF FOOTING 6" BELOW GRADE. IF TOWER FOUNDATION OBSTRUCTS AUGERED FOOTING, USE POST WITH 10" SQUARE GALVANIZED STEEL FLANGE PLATE WELDED TO BOTTOM AND BOLT FLANGE TO TOP OF CONCRETE TOWER FOOTING. 10B. AT MONOPOLE TOWERS CLAMP TDSGA—BC14 TOWER BOTTOM GROUND BAR DIRECTLY TO TOWER. IF RUNNING COAX INSIDE MONOPOLE, CLAMP ONTO BOTTOM LIP OF EXIT PORT. IF BANDING COAX TO OUTSIDE OF TOWER, CLAMP ONTO STEEL ANGLE WHICH IS BANDED TO TOWER. BOND TDSGA—BC14 TO TOWER GROUND RING WITH TWO #2 STC LEADS LUGGED TO GROUND BAR AND EXOTHERMICALLY WELDED TO GROUND RING. 11. AT EQUIPMENT AREA, INSTALL TDSGA—PA14 EXTERIOR GROUND BAR (THRU—BOLTED STYLE) AT BASE OF (2) INTERIOR H—FRAME POSTS AND AT TOP OF ICE BRIDGE POST WHICH IS NEAREST TO (BUT CLOSER TO TOWER THAN) THE COAX CABLE TERMINATION. MOUNT GROUND BAR TO H—FRAME POSTS AT 6" ABOVE GRAVEL AND TO ICE BRIDGE POST AT 6FT ABOVE GRAVEL. 12. ALL ICE BRIDGE SECTIONS ARE TO BE JUMPERED TOGETHER WITH #2 WIRE, EITHER BARE TINNED COPPER OR GREEN INSULATED STRANDED. ICE BRIDGE SHALL BE GROUNDED AT EACH END WITH #2 STC WIRE LUGGED TO ICE BRIDGE AND EXOTHERMICALLY WELDED TO UPPER PORTION OF NEAREST ICE BRIDGE POST. ICE BRIDGE SECTIONS ABOVE H—FRAME SHALL BE BONDED TO EACH OTHER WITH JUMPERS AT EACH END — THIS ASSEMBLY WILL BE CONSIDERED AS A SINGLE ICE BRIDGE SECTION FOR GROUNDING PURPOSES. 13. BOND EACH ICE BRIDGE POST, H—FRAME POST OR DEDICATED GROUNDING POST TO BURIED GROUNDING SYSTEM WITH #2 STC LEAD EXOTHERMICALLY WELDED TO POST BELOW TOP OF GRAVEL AND EXOTHERMICALLY WELDED TO GROUND RING. EACH POST TO HAVE SEPARATE GROUND LEAD DIRECTLY TO GROUND RING — DO NOT DAISY CHAIN POSTS TOGETHER. 14. BOND EACH RF CABINET TO EQUIPMENT GROUND RING WITH #2 AWG TINNED SOLID BARE COPPER CONDUCTOR LUGGED TO CABINET BODY AND EXOTHERMICALLY WELDED TO GROUND RING. LUG TO CABINET BODY USING LOCATION AT WHICH STUDS ON CABINET CHASSIS HAVE DIRECT GROUND WIRE CONNECTION TO CABINET INTERNAL GROUND BAR. RUN CONDUIT AND CONDUCTOR ACROSS BACK OF CABINET (DO NOT RUN TOWARDS NEAREST CORNER OF CABINET AND THEN BEND GROUND WIRE SHARPLY), ACROSS CONCRETE PAD BELOW CABLE LADDER, THEN DOWN INTO GRAVEL AREA. 15. BOND EACH BATTERY CABINET TO GROUND RING WITH #2 AWG TINNED SOLID BARE COPPER CONDUCTOR LUGGED TO CABINET BODY AND EXOTHERMICALLY WELDED TO GROUND RING. RUN GROUND LEAD IN FLEX CONDUIT ALONG BACK OF RBA72 CABINET, ACROSS CONCRETE PAD BELOW CABLE LADDER, THEN DOWN INTO GRAVEL AREA. CONNECT TWO HOLE LUG TO BACK OF CABINET AT FACTORY PROVIDED GROUNDING STUDS. 16. BOND GENERATOR TO GROUND RING WITH #2 STC AT TWO DIAGONALLY OPPOSITE LOCATIONS BY DRILLING AND BOLTING TWO HOLE LUG TO FINS ON GENERATOR BASE STRUCTURE. GROUND LEADS SHOULD TAKE SHORTEST PATH ACROSS CONCRETE PAD TO GRAVEL AREA, THEN CONTINUE TO GROUND RING. 17. WHERE PROPANE TANK IS INSTALLED TO FUEL GENERATOR, BOND PROPANE TANK TO GROUND RING WITH A SINGLE #2 STC CLAMPED TO FILLER PIPE OF PROPANE TANK AND EXOTHERMICALLY WELDED TO GROUND RING. GROUND LEAD SHOULD RUN TO TANK SUPPORT AND TAKE SHORTEST PATH ACROSS CONCRETE PAD TO GRAVEL AREA, THEN CONTINUE TO GROUND RING. IF PROPANE TANK FUEL LINE IS METALLIC AND CROSSES EQUIPMENT GROUND RING, BOND FUEL LINE TO EQUIPMENT GROUND RING WHERE THE TWO LINES CROSS WITH A SINGLE #2 STC CLAMPED TO FUEL LINE AND EXOTHERMICALLY WELDED TO GROUND RING. 18. BOND GPS ANTENNA and GPS ANTENNA MOUNT TO TSDGA GROUND BAR AT BOTTOM OF H—FRAME POST WITH #2 GREEN INSULATED STRANDED GROUND WIRE. 19. PROVIDE TWO GROUND RODS OUTSIDE GATES OF COMPOUND. DISTANCE BETWEEN GROUND RODS SHALL MATCH WIDTH OF GATE OPENING, AND DISTANCE FROM FENCE SHALL MATCH LENGTH OF LONGEST INDIVIDUAL GATE LEAF. BOND GATE POSTS TOGETHER WITH #2 STC LEAD WHICH RUNS PAST AND CONNECTS TO GROUND RODS OUTSIDE GATES. 20. BOND EACH GATE POST WITH #2 STC TO NEAREST PORTION OF GROUNDING SYSTEM INSIDE COMPOUND. 21. BOND EACH GATE TO GATE POST WITH FLEXIBLE INSULATED OR BRAIDED #4/0 COPPER STRAP. EXOTHERMICALLY WELD STRAP TO BOTH GATE AND GATE POSTS. 22. ANY METAL FENCE POST WITHIN 6FT OF A GROUNDED METAL OBJECT SHALL BE BONDED TO THE NEAREST GROUND RING. ANY METAL FENCE WITHIN 6FT OF A GROUND RING SHALL HAVE THE LINE POSTS BONDED TO THE GROUND RING AT 20FT MAXIMUM INTERVALS AS MEASURED ALONG THE LENGTH OF THE FENCE. 23. WHERE GROUND BASED RRU'S, RAYCAP OVP'S OR DIPLEXERS ARE INSTALLED AT THE EQUIPMENT AREA, BOND EACH COMPONENT TO NEAREST TDSGA GROUND BAR BELOW THE COMPONENT WITH #2 GREEN INSULATED STRANDED GROUND WIRE. SINGLE HOLE LUG OR RING TYPE CONNECTOR IS SUITABLE FOR CONNECTION TO GROUNDING STUD ON EACH COMPONENT. 24. NOTIFY VZW CM TO INSPECT GROUND RING BEFORE BACKFILLING. CONTRACTOR SHALL HIRE A 3RD PARTY TO PERFORM AN IEEE81 FALL OF POTENTIAL METHOD GROUND TEST. MAXIMUM ALLOWABLE RESISTANCE TO GROUND IS 5 OHMS. PROVIDE ADDITIONAL GROUND SYSTEM COMPONENTS AS REQUIRED TO ACHIEVE THIS VALUE. 25. REFER TO TOWER GROUNDING DIAGRAM AND NOTES FOR GROUND SYSTEM REQUIREMENTS ON THE TOWER. 26. GROUNDING OF ALL ELECTRICAL EQUIPMENT SHALL BE AS PER NEC, MUNICIPAL AND UTILITY COMPANY REQUIREMENTS. verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tS I l UI,s, • 0 •• SS/0."4• ,0, SEAL •• . 040828 : . . '.O•'•:LCINE1-.0•O ',. 'N. � . \A' *,♦ PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET GROUNDING NOTES —SHEET NUMBER. E8 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 x— x— x— x— x— x- PROPOSED 50' X 50' CHAIN LINK FENCED COMPOUND All i w !IR x GROUNDING PLAN SCALE: 1" = 10' x— x— x— x— x— x — X — ) / i — X — X 0 PROPOSED 300' GUYED TOWER 5 10 20 GRAPHIC SCALE: 1" = 10' KEY NOTES - GROUNDING EQUIPMENT • GROUND ROD TEST WELL (SEE DETAIL 1/E11). B GROUND ROD, TYPICAL B (SEE DETAIL 2/Ell AND NOTES 2 AND 3 ON E8). O TOWER AND EQUIPMENT GROUND RING (SEE NOTES 1, 3, 4, 5, 6 AND 7 ON E8). O TDSGA-PA14 OR TDSGA-BC14 WHERE APPLICABLE (SEE NOTES 10 AND 11 ON E8). OE GENERATOR GROUNDING (SEE NOTE 16 ON E8). OF GPS ANTENNA GROUNDING (SEE NOTE 18 ON E8). OG RF CABINET GROUNDING (SEE NOTE 14 ON E8). OH RRU'S AND OVP'S GROUNDING (SEE NOTE 23 ON E8). ICE BRIDGE POST BOND TO GROUND RING, TYPICAL • (SEE NOTES 12 AND 13 ON E8). O FENCE POST GROUNDING, TYPICAL. (SEE NOTE 22 ON E8). O GATE GROUNDING, TYPICAL. (SEE NOTES 19, 20 & 21 ON E8). O UTILITY H-FRAME GROUNDING, TYPICAL. (SEE SHEET E3 AND NOTE 13 ON E8). O TOWER GROUNDING, TYPICAL. (SEE NOTES 5, 6 & 25 ON E8). .0 GROUND RADIALS, TYPICAL (SEE NOTE 6 ON E8). REFER TO SHEETS E8, E10, Ell & E12 FOR GROUNDING NOTES, DETAILS, AND SPECIFICATIONS. O PROPANE TANK GROUNDING, IF INSTALLED (SEE NOTE 17 ON E8). • LEGEND: GROUND RING GROUND ROD EXOTHERMICALLY WELDED TO GROUND RING EXOTHERMIC WELD GROUND ROD TEST WELL (SEE DETAIL 1 /E11) �-O MECHANICAL CONNECTION verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY PLANS PREPARED BY: 201 Kimley* NORTH PHONE WWW.KIMLEY—HORN.COM FRANKUN STREET, TAMPA, FL 336D2 (813) 620-1460 Horn SURE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM LICENSER' • 0: .• SS/0•.••71•, 0i •SEAL •, . 040828 : . .. :0 .. C1NEF:.••p : .,• B'N. � . \)',,, PROJECT NUMBER' CKHA 140064078 BY: CHECKED BY. CDRAWN TDM TWD TITLE. _SHEET GROUNDING PLAN —SHEET NUMBER. E9 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 O #6 AWG INSULATED STRANDED COPPER. #6 AWG INSULATED STRANDED COPPER. CONNECT COAX GROUND KITS DIRECTLY TO TOWER TOP CIGBE ONLY AS NOTED ON DETAIL 3/E13. #2 AWG SOLID TINNED COPPER. #2 AWG SOLID TINNED COPPER. (IF GROUNDING POST NOT AVAILABLE) #2 AWG SOLID TINNED COPPER GROUND RING BURIED 30" BELOW GRADE. TOWER ACTS AS CONDUCTOR. TOWER GROUND BARS WILL BE ISOLATED FROM TOWER BUT BONDED TO TOWER WITH #2 AWG INSULATED STRANDED COPPER AND CLAMPED, OR EXOTHERMIC WELD, UNLESS OTHERWISE NOTED. 4/0 BRAIDED COPPER STRAP, EXOTHERMIC WELD TO BOTH GATE AND GATE POST. BOND GROUND BAR TO GROUNDING POST USING THROUGH BOLT CONNECTION. #2 AWG INSULATED STRANDED COPPER. Coax Ground Kit Cable 1/Feed Line (as required) Sector CIGBE (See Note 7) Coax Ground Kit Cable 1/Feed Line 0 GPS Antenna 0 @ EQUIPMENT Coax Ground Kit Cable 1/Feed Line @ TOWER Coax Ground Kit Cable 1/Feed Line Intermediate CIGBE (See Note 7) Tower Top CIGBE (See Note 7) Utility Rack Gate Post --- c—ate` o Ground Ring \ Outside Compound o \ 0 Tower Ground Ring I e Main Exterior Ground Bar Tower Bottom Ground Bar Grounding Post 0 0 0 I 0 0 Fence Corner Grounding Post (Lattice) Power • 1 GROUNDING SINGLE LINE DIAGRAM NOT TO SCALE 1 I • • • 0 0 Cabinets 0 Cable Tray • Generator (OUTDOOR) Tie Down Plates (INDOOR) 1 I 0 I 1 I 1 I 0 0 O 2222222 11.1.1=m=m11 PROPOSED ANTENNA. COAX OR HYBRID CABLE GROUNDING KIT, TYPICAL. GROUNDING KITS ARE REQUIRED EVERY 75 FT MAXIMUM EXCEPT WHERE COAX IS CONCEALED INSIDE MONOPOLE OR OTHER INACCESSIBLE SPACE. #6 AWG INSULATED GROUNDING CONDUCTOR FROM COAX GROUND KIT TO TOWER GROUND BAR, TYPICAL. SECTOR CIGBE GROUND BAR, PROVIDE ONE PER SECTOR NEXT TO ANTENNAS (OPTIONAL ON GUYED TOWERS) AND ISOLATED FROM TOWER. BOND TO TOWER OR SECTOR FRAME WITH #2 AWG SOLID TINNED COPPER AND APPROVED CLAMP. (SEE NOTE P BELOW) TOWER TOP CIGBE GROUND BAR MOUNTED TO TOWER WHERE COAX CABLES LEAVE VERTICAL WAVE GUIDE SUPPORT OR COMMON CABLE TRAY. TYPICALLY OCCURS ON GUY TOWERS (IN LIEU OF SECTOR CIGBE'S), ROOFTOPS, OR ON WATER TANKS (THRU—BOLTED TO MESSENGER PIPE) IN ORDER TO MAINTAIN 75 FEET MAXIMUM DISTANCE BETWEEN COAX GROUND KITS. ISOLATE CIGBE FROM TOWER AND BOND TO TOWER WITH #2 AWG BARE SOLID TINNED COPPER AND APPROVED CLAMP. (SEE NOTE P BELOW) COAX OR HYBRID CABLE. #2 AWG INSULATED, STRANDED COPPER. (SEE NOTE P BELOW) INTERMEDIATE CIGBE GROUND BAR MOUNTED TO TOWER BELOW AND WITHIN 3 FEET OF COAX GROUND KITS AND ISOLATED FROM TOWER (THRU—BOLTED TO MESSENGER PIPE ON WATER TANKS). BOND TO TOWER WITH #2 AWG BARE SOLID TINNED COPPER AND APPROVED CLAMP. (SEE NOTE P BELOW) TOWER BOTTOM GROUND BAR TDSGA—PA14 ON DEDICATED STEEL POST WHERE POSSIBLE; OTHERWISE TDSGA—BC14 CLAMPED DIRECTLY TO TOWERS STEEL (THRU—BOLTED TO MESSENGER PIPE ON WATER TANKS). #2 AWG BARE STRANDED TINNED COPPER GROUNDING CONDUCTOR WHEN USING TDSGA—BC14. TYPICAL TWO CONNECTIONS TO GROUND RING. #2 AWG SOLID TINNED COPPER TOWER GROUND RING. DRIP LOOP, SEE DETAIL 1/E7. TO SHELTER/RF CABINETS. IF UNABLE TO CLAMP #2 AWG BARE SOLID TINNED COPPER TO METAL STRUCTURE, THEN RUN #2 AWG INSULATED STRANDED TINNED COPPER FROM CIGBE TO NEXT LOWEST CIGBE. (SEE DETAIL 3/E12). PROPOSED RRU. PROPOSED RAYCAP. TOP OF GRAVEL. COAX -TOWER GROUNDING SCHEMATIC NOT TO SCALE s vertic la idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: — BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tS,. UI,s, • O�:oESS/p�•'2• 0: � 9� 57 • SEAL •. . 040828 : ',. 'N. � . \A' *♦♦ PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET GROUNDING SINGLE LINE DIAGRAM —SHEET NUMBER. El This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 THREADED 8" DIAMETER SCHEDULE 40 PVC PLUG. FINISHED GRADE. CRUSHED AGGREGATE, SEE 111 I 1-1 I 1-III- CIVIL DRAWINGS FOR DETAILS. II 1 11I I 1 LOOP GROUND RING INTO TEST WELL. r-III � 111- IrEdlk COMPACTED BACKFILL. IrEn EIIE 1 1=1 1 8" DIAMETER SCHEDULE 40 PVC PIPE WITH VERTICAL SLOT TO ALLOW PIPE PLACEMENT THRU GROUND RING. #2 AWG BARE SOLID TINNED COPPER GROUND RING, EXOTHERMIC WELD TO GROUND ROD. 5/8" x 10' COPPER CLAD GROUND ROD. 6" OF CRUSHED AGGREGATE. GROUND ROD TEST WELL DETAIL NOT TO SCALE FINISHED GRADE. CRUSHED AGGREGATE, SEE CIVIL DRAWINGS FOR DETAILS. EXOTHERMIC WELD, SEAL WITH TWO (2) COATS OF COLD GALVANIZED PAINT. GROUND RO NDRING SOLID TINNED EXOTHERMIC#2 WELD TO GROUND ROD. %'' x 10' COPPER CLAD GROUND ROD. PLACEMENT OF GROUND ROD SHALL NOT EXCEED 30 DEGREES FROM VERTICAL. GROUND ROD INSTALLATION DETAIL NOT TO SCALE verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tSIlUI, • O ;.• SS/0 . 71, 0, • •SEAL •• . 040828 : : '.O.'•:LCINE1-.0•O B PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET GROUNDING DETAILS —SHEET NUMBER. Ell This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 • TINNED COPPER LONG —BARREL DOUBLE —LUG CONNECTOR, TYPICAL. STAINLESS STEEL SPACER, TYPICAL. STAINLESS STEEL BEAM CLAMP, TYPICAL. STAINLESS STEEL HARDWARE, TYPICAL. BAR NONE GROUNDED BEAM CLAMP (TDSGA-BC14) NOT TO SCALE 0 0 4 0 0 4 0 U U 0 0 0 0<> <>0 0 0 • 0 4 #6 AWG INCOMING GROUNDING CONDUCTORS FROM COAX GROUNDING KITS. (FOR TOWER TOP CIGBE'S OCCURS ONLY ON GUYED TOWERS, OR ON OTHER STRUCTURES WHERE REQUIRED TO ACHIEVE 75 FT MAXIMUM DISTANCE BETWEEN COAX GROUNDING LOCATIONS.) CIGBE GROUND BARS ON ANTENNA TOWER, ISOLATE FROM TOWER. #2 AWG GROUNDING CONDUCTOR RUN FROM CIGBE TO TOWER USING CLAMP, OR RUN #2 AWG INSULATED GROUNDING CONDUCTOR TO NEXT LOWER CIGBE. ANTENNA GROUND WIRE INSTALLATION DETAIL NOT TO SCALE NOTES: 1. ALL CIGBE GROUND BARS ON TOWER ARE TO BE ERICO TDSGA. TYPICALLY USE TDSGA—WB17 ISOLATED FROM UNISTRUT BRACKET. 2. IF CIGBE CANNOT BE CONNECTED TO TOWER WITH #2 AWG GROUNDING CONDUCTOR, VIA CLAMP OR EXOTHERMIC WELD, THEN RUN #2 AWG BLACK GROUND LEAD FROM CIGBE DOWN TO NEXT LOWER CIGBE. SECURE GROUND LEAD WITH NON—METALIC TIES AT SAME SPACING AS COAX SUPPORTS. • TINNED COPPER LONG —BARREL DOUBLE —LUG CONNECTOR, TYPICAL. STAINLESS STEEL HARDWARE, TYPICAL. STAINLESS STEEL SPACER, TYPICAL. BAR NONE POST MOUNTED (TDSGA-PA14) NOT TO SCALE TINNED COPPER LONG —BARREL DOUBLE —LUG CONNECTOR, TYPICAL. INSULATOR. STAINLESS STEEL HARDWARE, TYPICAL. STAINLESS STEEL SPACER, TYPICAL. BAR NONE INSULATED (TDSGA-WB17) NOT TO SCALE verric la bridge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER• ,,%*tS I l UI,s, .�4N CAR0 .. • 0 .• __SS/0 .• "4, ': � 9� 57 • •SEAL •• . 040828 : • e . :0 •.F' Al../ : .,B'N. � . \A' *,, PROJECT NUMBER' CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET GROUNDING DETAILS —SHEET NUMBER. E12 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022 KEY DESCRIPTION 0 BOND GUY WIRES TO PROPOSED GROUND RING. O BOND GROUND RING(S) TO SITE CORNER POST (TYP. x 4). O BOND GATE POST TO PROPOSED GROUND RING (TYP. x 2). O BOND FLEXIBLE JUMPER TO GATE (TYP. x 2). O PROPOSED GROUND RING AROUND GUY WIRE ANCHOR POINT. O BOND GUY WIRE ANCHOR TO PROPOSED GROUND RING. EXTERIOR GROUNDING NOTES: THE LOCATION, SIZE AND TYPE OF MATERIAL OF EXISTING UTILITIES INDICATED ON THE PLANS IS NOT REPRESENTED AS BEING ACCURATE, SUFFICIENT OR COMPLETE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE ACTUAL LOCATION OF ALL SUCH FACILITIES, INCLUDING THE SERVICE CONNECTIONS TO UNDERGROUND UTILITIES. PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL NOTIFY THE UTILITY COMPANIES OF HIS OPERATIONAL PLANS AND SHALL OBTAIN FROM THE RESPECTIVE UTILITY COMPANIES DETAILED INFORMATION AND ASSISTANCE RELATIVE TO THE LOCATION OF THEIR FACILITIES AND THE WORKING SCHEDULE OF THE COMPANIES FOR REMOVAL OR ADJUSTMENT WHERE REQUIRED. IN THE EVENT AN UNEXPECTED UTILITY INTERFERENCE IS ENCOUNTERED DURING CONSTRUCTION, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE UTILITY COMPANY OF JURISDICTION. THE ENGINEER SHALL ALSO BE IMMEDIATELY NOTIFIED. — X— X— X— X— X— X— X— X— X— X— X— X— X— X— X— X—X—X �x0— x — x — x — x — x — x — x — x — x — x — x — x — x — x — x — x — x — x — x� • GUY ANCHOR GROUNDING PLAN NOT TO SCALE 1. GROUNDING SHALL CONFORM WITH VERTICAL BRIDGE STANDARDS AND PER FEDERAL, STATE AND LOCAL CODES. IN THE EVENT OF A CONFLICT, MEET THE MOST STRINGENT REQUIREMENT. 2. GROUND RODS PAST METER SHALL BE COPPER CLAD STEEL 5/8 INCH DIAMETER X 10 FEET IN LENGTH (MIN.) 3. ALL GROUND CONDUCTORS PAST METER SHALL BE #2 AWG SOLID BARE TINNED COPPER. MINIMUM BEND RADIUS FOR CONDUCTOR SHALL BE 8 INCHES. 4. GROUND RODS SHALL BE SPACED NOT MORE THAN 16'-0" AND NOT LESS THAN 6'-0" APART EXCEPT FOR THE TOWER GROUND RING WHICH SHALL COMPLY WITH TIA/EIA 222 (REV G). 5. CONTRACTOR SHALL ADD ADDITIONAL RODS AND CONDUCTORS OR APPROVED GROUND ENHANCING MATERIAL TO ACHIEVE LESS THAN 10 OHMS RESISTANCE TO GROUND. 6. MAINTAIN 2'-0" (TOWER) AND 3'-0" (SHELTER) BETWEEN GROUND RINGS AND FOUNDATIONS. 7. ALL GROUNDING INSTALLATIONS SHALL BE INSPECTED AND APPROVED BY ANY JURISDICTION HAVING INSPECTION & APPROVAL AUTHORITY (IF REQUIRED) AND VERTICAL BRIDGE BEFORE PLACING ANY BACKFILL. 8. ALL GROUNDING SPLICES AND CONNECTIONS SHALL BE MADE BY THE EXOTHERMIC WELD PROCESS (CADWELD OR EQUIVALENT). COAT ALL WELDS WITH A ZINC RICH PAINT. 0 2.5 5 10 GRAPHIC SCALE: 1" = 5' vertic la b idge 700 PARK OF COMMERCE DRIVE BOCA RATON FL, 33487 TEL: (561) 948-6367 =PROJECT INFORMATION. SITE NAME: BLUE PANTHER SITE No.: US-NC-5181 PROJECT #: 140064078 6720 NC 210 HWY HARRELLS, NC 28444 BLADEN COUNTY =PLANS PREPARED BY: 201 Kimley>>>Horn NORTH PHONE WWW.KIMLEY—HORN.COM FRANKLIN STREET, TAMPA, FL 33602 (813) 620-1460 SUITE 150 =REV: —DATE: —ISSUED FOR: —BY:- 8 7 6 5 4 3 2 07/20/22 CONSTRUCTION TDM 1 06/29/22 CONSTRUCTION TDM 0 05/31/22 FOR REVIEW TDM =LICENSER ,,%*tS,l UI,s, • O�:oESS/0••� •: • : Q� 9� 5� • •SEAL •• . 040828 : e e . e'N. �:.\A' *,, PROJECT NUMBER. CKHA 140064078 DRAWN BY: CHECKED BY. 1 TDM TWD TITLE. _SHEET GUY WIRE GROUNDING AND FENCE DETAILS -SHEET NUMBER. E13 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which R was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Hom and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2022