Loading...
HomeMy WebLinkAbout- 8/12/2022 12:56 AM—ss N/F BETTY AYSCUE DB:006374, PG 571 w z J O EXISTING WETLAND (TO BE VERIFIED BY USACE) �20' EXISTING SANITARY SEWER EASEMENT BM 2005 PG 750 TIE INTO EXISTING SEWER MANHOLE ss PROPOSED 30' SANITARY SEWER EASEMENT ND IMPACT: :ET 30' EXISTING SANITARY SEWER EASEMENT BM 2020 PG 346 0, PRIVATE 6" PVC SANITARY SEWER ss 0 0 M ss 30' EXISTING SANITARY SEWER ,-,---- EASEMENT BM 2020 PG 346 W EXISTING RAILROAD R/W SCALE: 1" = 50' CITY OF RALEIGH STANDARD UTILITY NOTES 1. ALL MATERIALS & CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH CITY OF RALEIGH DESIGN STANDARDS, DETAILS & SPECIFICATIONS (REFERENCE: CORPUD HANDBOOK, CURRENT EDITION). 2. UTILITY SEPARATION REQUIREMENTS: a) A DISTANCE OF 100' SHALL BE MAINTAINED BETWEEN SANITARY SEWER & ANY PRIVATE OR PUBLIC WATER SUPPLY SOURCE SUCH AS AN IMPOUNDED RESERVOIR USED AS A SOURCE OF DRINKING WATER. IF ADEQUATE LATERAL SEPARATION CANNOT BE ACHIEVED, FERROUS SANITARY SEWER PIPE SHALL BE SPECIFIED & INSTALLED TO WATERLINE SPECIFICATIONS. HOWEVER, THE MINIMUM SEPARATION SHALL NOT BE LESS THAN 25' FROM A PRIVATE WELL OR 50' FROM A PUBLIC WELL. b) WHEN INSTALLING WATER AND/OR SEWER MAINS, THE HORIZONTAL SEPARATION BETWEEN UTILITIES SHALL BE 10'. IF THIS SEPARATION CANNOT BE MAINTAINED DUE TO EXISTING CONDITIONS, THE VARIATION ALLOWED IS THE WATER MAIN IN A SEPARATE TRENCH WITH THE ELEVATION OF THE WATER MAIN AT LEAST 18" ABOVE THE TOP OF THE SEWER AND MUST BE APPROVED BY THE PUBLIC UTILITIES DIRECTOR. ALL DISTANCES ARE MEASURED FROM OUTSIDE DIAMETER TO OUTSIDE DIAMETER c) WHERE IT IS IMPOSSIBLE TO OBTAIN PROPER SEPARATION, OR ANYTIME A SANITARY SEWER PASSES OVER A WATERMAIN, DIP MATERIALS OR STEEL ENCASEMENT EXTENDED 10' ON EACH SIDE OF CROSSING MUST BE SPECIFIED & INSTALLED TO WATERLINE SPECIFICATIONS. d) 5.0' MINIMUM HORIZONTAL SEPARATION IS REQUIRED BETWEEN ALL SANITARY SEWER AND STORM SEWER FACILITIES, UNLESS DIP MATERIAL IS SPECIFIED FOR SANITARY SEWER. e) MAINTAIN 18" MIN. VERTICAL SEPARATION AT ALL WATERMAIN AND RCP STORM DRAIN CROSSINGS; MAINTAIN 24" MIN. VERTICAL SEPARATION AT ALL SANITARY SEWER AND RCP STORM DRAIN CROSSINGS. WHERE ADEQUATE SEPARATIONS CANNOT BE ACHIEVED, SPECIFY DIP MATERIALS AND A CONCRETE CRADLE HAVING 6" MIN. CLEARANCE (PER CORPUD DETAILS W-41 & S-49). SEE CORPUD DETAILS ON SHEET 6 & 7/C-804. f) ALL OTHER UNDERGROUND UTILITIES SHALL CROSS WATER & SEWER FACILITIES WITH 18" MIN. VERTICAL SEPARATION REQUIRED. 3. ANY NECESSARY FIELD REVISIONS ARE SUBJECT TO REVIEW & APPROVAL OF AN AMENDED PLAN AND/OR PROFILE BY THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT PRIOR TO CONSTRUCTION. W W * * PUBLIC 8" DIP W SANITARY SEWER W W W W / /'6' * W W /v W * * / w z J 0 EXISTING WETLAN- D (TO BE VERIFIED BY USACE) W W W W W * W l ss� ��ss �S / * * W/ / W W W */ W ss W ss W i PROPOSED 30' SANITARY SEWER EASEMENT PROPOSED WETLAND IMPACT: 1,041 SQUARE FEET 2" DOMESTIC SERVICE LINE -i TERMINATE WITH 2" CAP AND BALL VALVE 30' EXIST SANITARY EASEMENT BM 2020 EXISTING RAILROAD RIGHT OF WAY 1 1 1 \ - � o2 ��a.QG PRIVATE 6" PVC PRIVATE SANITARY SEWER FIRE LINE: •4" SEWER .•.•.• SERVICE •••• • WV • • • • .. .'. _.^ 4y. Q1 - • • W EXISTING CONCRETE PAD TO REMAIN IN PLACE 4. CONTRACTOR SHALL MAINTAIN CONTINUOUS WATER & SEWER SERVICE TO EXISTING RESIDENCES AND BUSINESSES THROUGHOUT CONSTRUCTION OF PROJECT. ANY NECESSARY SERVICE INTERRUPTIONS SHALL BE PRECEDED BY A 24 HOUR ADVANCE NOTICE TO THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT. 5. 3.0' MINIMUM COVER IS REQUIRED ON ALL WATER MAINS AND SEWER FORCEMAINS. 4.0' MINIMUM COVER IS REQUIRED ON ALL REUSE MAINS. 6. IT IS THE DEVELOPER'S RESPONSIBILITY TO ABANDON OR REMOVE EXISTING WATER AND SEWER SERVICES NOT BEING USED IN REDEVELOPMENT OF A SITE UNLESS OTHERWISE DIRECTED BY THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT. THIS INCLUDES ABANDONING TAP AT MAIN AND REMOVAL OF SERVICE FROM ROW OR EASEMENT PER CORPUD HANDBOOK PROCEDURE. 7. PRESSURE REDUCING VALVES ARE REQUIRED ON ALL WATER SERVICES EXCEEDING 80 PSI; BACKWATER VALVES ARE REQUIRED ON ALL SANITARY SEWER SERVICES HAVING BUILDING DRAINS LOWER THAN 1.0' ABOVE THE NEXT UPSTREAM MANHOLE. 8. ALL ENVIRONMENTAL PERMITS APPLICABLE TO THE PROJECT MUST BE OBTAINED FROM NCDWQ, USACE &/OR FEMA FOR ANY RIPARIAN BUFFER, WETLAND &/OR FLOODPLAIN IMPACTS (RESPECTIVELY) PRIOR TO CONSTRUCTION. 9. GREASE INTERCEPTOR / OIL WATER SEPARATOR SIZING CALCULATIONS & INSTALLATION SPECIFICATIONS SHALL BE APPROVED BY THE CORPUD FOG PROGRAM COORDINATOR PRIOR TO ISSUANCE OF A BUILDING PERMIT. CONTACT TIM BEASLEY AT (919) 250-7825 OR TIMOTHY.BEASLEY@RALEIGHNC.GOV FOR MORE INFORMATION 10. CROSS —CONNECTION CONTROL PROTECTION DEVICES ARE REQUIRED BASED ON DEGREE OF HEALTH HAZARD INVOLVED AS LISTED IN APPENDIX—B OF THE RULES GOVERNING PUBLIC WATER SYSTEMS IN NORTH CAROLINA. THESE GUIDELINES ARE THE MINIMUM REQUIREMENTS. THE DEVICES SHALL MEET AMERICAN SOCIETY OF SANITARY ENGINEERING (ASSE) STANDARDS OR BE ON THE UNIVERSITY OF SOUTHERN CALIFORNIA APPROVAL LIST. THE DEVICES SHALL BE INSTALLED AND TESTED (BOTH INITIAL AND PERIODIC TESTING THEREAFTER) IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR THE LOCAL CROSS —CONNECTION CONTROL PROGRAM, WHICHEVER IS MORE STRINGENT. CONTACT JOANIE HELVEY AT (919) 212-5923 OR JOANIE.HARTLEY®RALEIGHNC.GOV FOR MORE INFORMATION. XISTING MONOPOLE TOWER TO REMAIN ELEV: 319.6' HEIGHT: 174.9' EXISTING BUILDING TO REMAIN 4" SEWER SERVICE 4" SEWER SERVICE 600 I EXISTING TRANSFORMER' x — i" DOMESTIC SERVICE LINE I w ....i.• ....:.4 i" DOMESTIC SERVICE LINE 2" DOMESTIC SERVICE LINE 6" RPDA BACKFLOW PREVENTER IN ABOVE GROUND HOTBOX. WATTS 957RPDA OR APPROVED EQUAL PRIVATE 6" DIP FIRE LINE 2" DOMESTIC SERVICE LINE EXISTING OVERHEAD ELECTRIC TO REMAIN ' EXISTING OVERHEAD ELECTRIC TO REMAIN PRIVATE 6" DIP FIRE LINE 2" RPZ BACKFLOW PREVENTER IN ABOVE GROUND HOTBOX. WATTS 2 LF909M 1—QT OR APPROVED EQUAL 6" RPDA BACKFLOW PREVENTER IN ABOVE GROUND HOTBOX. WATTS 957RPDA OR APPROVED EQUAL 6 PUBLIC 6" DIP WATER LINE 00 ' i O WV 2" DOMESTIC WATER METER CITY OF RALEIGH WATERLINE EASEMENT (5' ALL SIDES OF METER) SCALE: 1" = 20' N/F WILLIAM FOGLEMAN DB:008415, PG 02623 BM 1996, PG 396 PUBLIC 6" DIP WATER LINE 2" DOMESTIC WATER METER CITY OF RALEIGH WATERLINE EASEMENT 2" RPZ BACKFLOW PREVENTER IN ABOVE GROUND HOTBOX. WATTS 2 LF909M 1—QT OR APPROVED EQUAL GENERAL NOTES EXISTING 6" WATERLINE EXISTING FH EXISTING BLOW OFF ASSEMBLY REMOVE EXISTING BLOW OFF ASSEMBLY AND EXTEND PROPOSED 6" DIP WATERLINE 1. CONTRACTOR TO FIELD VERIFY LOCATION & ELEVATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. 2. UTILITY CONSTRUCTION SHALL BE IN ACCORDANCE WITH CITY OF RALEIGH STANDARDS AND SPECIFICATIONS UNLESS OTHERWISE NOTED. 3. CONTRACTOR IS RESPONSIBLE FOR CONTACTING AND COORDINATING WITH ALL UTILITY SERVICE PROVIDERS THAT HAVE UTILITIES ON OR IMMEDIATELY ADJACENT TO THE SITE AND WORK AREA. 4. STORM DRAINAGE INSTALLATION SHALL BE IN ACCORDANCE WITH WAKE FOREST STANDARDS AND SPECIFICATIONS. 5. ALL UTILITIES MUST BE INSTALLED PRIOR TO INSTALLATION OF FINAL PAVEMENT SURFACE ON LIGON MILL. 6. ALL WATER AND SEWER BEHIND THE METER OR RIGHT OF WAY TO BE PERMITTED AND INSPECTED BY TOWN OF WENDELL INSPECTIONS. 7. THE SITE SHALL BE CONSTRUCTED IN TWO PHASES. PHASE 1 WILL INCLUDE CONSTRUCTION OF PARKING, ASPHALT, DRIVE AISLES, AND SIDEWALK ASSOCIATED WITH 600 AND 601 COOK STREET AS SHOWN ON THE APPROVED DRAWINGS. PHASE 1 WILL ALSO INCLUDE CONSTRUCTION OF ALL PUBLIC SEWER, PRIVATE SEWER, PUBLIC WATER, PRIVATE WATER, DOMESTIC METERS, BACKFLOW PREVENTERS, SEWER LATERAL CONNECTIONS, WATER SERVICES, FIRE HYDRANTS, STORM DRAINAGE CONVEYANCE AND SCM AS SHOWN ON THE APPROVED DRAWINGS. PHASE TWO WILL INCLUDE THE REMAINING PARKING, ASPHALT, DRIVE AISLES, AND SIDEWALK ASSOCIATED WITH 603 AND 606 COOK STREET. 8. SEWER FROM THE EXISTING OFFSITE MANHOLE TO MANHOLE 2 (MH-2) WILL BE 8" PUBLIC SEWER. SEWER FROM MANHOLE 2 (MH-2) TO CLEANOUT 11 (C0-11) WILL BE 6" PRIVATE SEWER. ALL OTHER CLEANOUTS AND SEWER LATERALS SHOWN ARE BUILDING SERVICES. 9. ALL LOTS TO BE RECOMBINED AT FINAL PLATTING. RALEIGH CIVIL DESIGN CONSULTING ENGINEERS + LAND SURVEYORS NC License P-1934 1129 Groveview Wynd Wendell, NC 27591 252.908.5722 lewis@raleighcivildesign.com Seals wog FS �_ C 1• ocpCRgT '11 W SEAL p z S" P-1934 ▪ •- ' NTH CAR°\ ///ii Project WENDELL BUSINESS PARK Cook Street Wendell, NC 27591 Client CREEDMOOR BUSINESS PARK, LLC 621 WOODS WAY WAKE FOREST, NC 27587 (252) 767-1842 ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WENDELL, CITY OF RALEIGH AND NCDOT STANDARDS AND SPECIFICATIONS NO WETLANDS EXIST ON -SITE NO FLOODPLAINS EXIST ON -SITE 50' w ss LEGEND EX. SANITARY SEWER MANHOLE x1 EX. WATER VALVE PROPOSED FIRE HYDRANT (FH) N PROPOSED WATER VALVE (WV) • PROPOSED WATER METER (WM) • PROPOSED MANHOLE (MH) • PROPOSED CLEANOUT (CO) • PROPOSED WATER LINE PROPOSED SANITARY SEWER EXISTING GAS LINE PROPOSED NYLOPLAST INLET PROPOSED FLARED END SECTION PROPOSED STORM PIPE GAS - ss 25' 0 EXISTING WETLAND LIMITS OF DISTURBANCE 50' 100' 1 "=50' Drawing Title UTILITY PLAN Revisions Date Description By RCD #: 22-001 Drawn By: LEH Checked By: LEH Date Issued: 3/13/22 CE-5.0 i GENERAL NOTES \Z 20' EXISTING SANITARY SEWER EASEMENT BM 2005 PG 750 EX5'DIA. SS MH EX TOP 307.80 INV OUT 289.94 \ \ \i \v \ I \ \ 1\ \ <'C \\ ss\ \ \ II \ \ \ I \\ s _\- - N/F BETTY AYSCUE II �•/ s s \ DB:006374, PG 571 \ // \\ \0+0 ' \` / \ EX 5' DIA. SS MH 1 TOP 307.10 INV IN 289.47 INV IN 295.11 INV OUT 289.47 7 30' EXISTING SANITARY SEWER W W EASEMENT BM 2020 PG 346 TIE INTO EXISTING / * _ r * fSEWER MANHOLE / r W * / / PUBLIC 8" DIP �,`, * j o SANITARY SEWER W `r' 4 .�;/ * * 0 1+00" // /// ' / 2+00 W W r W/ 11, i' -.3+00, / / T_, � �_ ss *_ ss / / / - / v I \ \ - // / ' EXISTING WETLAND (TO BE VERIFIED BY USACE) W W W �� -- - - - - - - - - _ ' 7 / _ - - / ' / EXISTING RAILROAD R/W W W W L. / / / / / I s 30' EXISTING SANITARY SEWER / EASEMENT BM 2020 PG 346 - I / - - - ,/ , MH-2 ' ''_/// / I �\ �'/ /','' PRIV TE 6" PVC SANITARY / - /- - // / I \ _ : -_ 1' -- _ _ _ _ - - _ PROPOSED 30' SANITARY �,/ j : SEWERS _ - ,-;,319 -__ \ /'�' _ - - - - - t L_ - - - - --- SEWER EASEMENT ' / ,' / - ' /- / / / 321- - '�- -_2�_ -- - I.-1,5-7-_ 318 � \\ \\ �/ - --=�-- _ ---------=_= ''/ 315 - -____�___ ______________--- PROPOSED WETLAND IMPACT: - = - _/�/ �, -- - - _------====- ____________ --===_-- --- -- - - - _ 1,041 SQUARE FEET _ - -- - - --- = - --------- ___---------- - -- - - -- - - - - i Private Sewer Collection / Extension System The City of Raleigh consents to the connection to it's to its public sewer system and extension of the private sewer collection system as shown on this plan. The material and construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. Public Utilities Department Permit # Authorization to Construct Date //' / '7/ // // / / '% i //' '/ ,'\ / � ' - \ k ce'%/' < ��j i i i lr �A11,000 A A��ANA1� Ioo ��A�A•!� `\ . - �AA����A VA A :4 .'•.'•.. Public Sewer Collection / Extension System The City of Raleigh consents to the connection and extension of the City's public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Utilities Handbook CO:1)t9fdREielglgh Public Utilities Department Permit # Authorization to Construct Date PRIVATE 6" PVC SANITARY SEWER / / VimI 7I , ' 7 1 2" DOMESTIC SERVICE LINE TERMINATE WITH 2" CAP I AND BALL VALVE Chi' - - -I -4 _ 2" DOMESTIC SERVICE LINE 606 ATTENTION CONTRACTORS The Construction Contractor responsible for the extension of water, sewer, and/or reuse, as approved in these plans, is responsible for contacting the Public Utilities Department at (919) 996-4540 at least twenty four hours prior to beginning any of their construction. Failure to notify both City Departments in advance of beginning construction, will result in the issuance of monetary fines, and require reinstallation of any water or sewer facilities not inspected as a result of this notification failure. Failure to call for Inspection, Install a Downstream Plug, have Permitted Plans on the Jobsite, or any other Violation of City of Raleigh Standards will result in a Fine and Possible Exclusion from future work in the City of Raleigh. 000 PRIVATE 6" PVC SANITARY SEWER 3 C 320 PR VATE 6'` DIP I LIN /F�__.. : 0_ / FH • ; 4" SEWER Z. SERVICE / 32 4" SEWER SERVICE II I / 6' SEWER SERV CE CO PRIVATE 6" PVC SERVICE II SANITARY SEWER : J .. '...... 4" SEWER -1 i.. ..,'i{.'. SERVICE / EXISTING 1. CONTRACTOR TO FIELD VERIFY LOCATION & ELEVATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. / 2. UTILITY CONSTRUCTION SHALL BE IN ACCORDANCE WITH CITY OF RALEIGH STANDARDS AND SPECIFICATIONS UNLESS OTHERWISE NOTED. 3. STORM DRAINAGE INSTALLATION SHALL BE IN ACCORDANCE WITH NCDOT STANDARDS AND SPECIFICATIONS. 4" SEWER SERVICE 600 CA i" DOMESTIC SERVICE LINE i" DOMESTIC • SERVICE LINE ------------- 601 4" SEWER SERVICE TRANSFORMER -- /-- z� _ - - / i - 15" SEWER 330 330 325 325 -PROPOSED o GRADE Ln in �� 0 � N M 0� M 320 0 00 ^ .. (13 • a0 0 c•0N cDa)MM OCOin M M �M�M- ±NH 320 61-In N g • M ._.� �M 0 c0 co�O co O M cnacc; IS I r M r +iM 0U.-M O+6 M r Z O.-M0 I� OcOM +NMI Z O O co Lc)• rn gu Oc0 0 �• � M O 00 Z OO O Z O O Q0- >> ccN<- <O> z - v- Lo V NCl-12 z z - ad 0c0 M rrna0 M oar M I- ! z �cn� HO» ! z z �rn� HO» i0(~/I� ? ? Z Z to ,0 O n M O oD _ / -ram - 315 � o^ co M M �� � (~/1 � z z/ 3'IN 315 13 un o� z z �T�_� 0 O H v+i M z p ' f� / EXISTING GRADE z (DIP) 0 u? iO a 1- O >> v1 � 5' MINI m - � � a M •+ - - / (PVC) + M r- 66.02 LF 6" DIP 0 3.25% 310 O*M Z - 310 'PVC 0 1.00% _ (Dun_ 1-0 z z CONCRETE CRADLE LF 6' - 100.00 RCP SEE DETAIL S-49 6" PVC ® 1 00% i 15" cu .. v 100.00 LF 74 38 LF 6" PVC 0 1.01% EX MH 1 STA 0+00 = 0 0 _ 305 TOP 307.10 1- r rn O1 a LF 6" PVC ® 1.00% 305 INV IN 289.47 (EX) INV IN 295.11 (2) r-- Sri N / 95.34 ® 1.00% ¢ 0 M M z o gg.34 LF 6" PVC INV OUT 289.47 64.58 LF 6" PVC 0 1.00%- < o > > / - �NH Z Z 64.58 LF 6" PVC 0 1.00% RCP 300 \ 9��0 g• 300 � 3' MIN 0 QG EXISTING GRADE (PVC) �F 295 295 LF 8" DIP 0 0.60% 379.47 290 290 INSIDE DROP SEE DETAIL S-53 -CENTERLINE - - - - - - - - - ELEVATIONS RALEIGH CIVIL DESIGN CONSULTING ENGINEERS + LAND SURVEYORS NC License P-1934 1129 Groveview Wynd Wendell, NC 27591 252.908.5722 lewis@raleighcivildesign.com Seals FS �_ SEAL 1 \ Z P-1934r- o MTh CAR��• �```` /////illl'1` Project WENDELL BUSINESS PARK Cook Street Wendell, NC 27591 Client CREEDMOOR BUSINESS PARK, LLC 621 WOODS WAY WAKE FOREST, NC 27587 (252) 767-1842 ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WENDELL, CITY OF RALEIGH AND NCDOT STANDARDS AND SPECIFICATIONS NO WETLANDS EXIST ON -SITE NO FLOODPLAINS EXIST ON -SITE 50' 25' 0 50' 100' 1 "=50' Drawing Title SEWER EXTENSION PLAN & PROFILE Revisions Date Description By RCD #: 22-001 0 + 00.00 1 + 00.00 2 + 00.00 3 + 00.00 4 + 00.00 5 + 00.00 6 + 00.00 7 + 00.00 8 + 00.00 9+00.00 10+00.00 11 + 00.00 12 + 00.00 13 + 00.00 Drawn By: LEH Checked By: LEH Date Issued: 3/13/22 CE-5.1 i