Loading...
HomeMy WebLinkAboutWQCSD0311_Compliance Evaluation Inspection_20220812ROY COOPER Governor ELVEABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Shannon V. Becker, President Aqua North Carolina, Inc. 202 MacKenan Court Cary, NC 27511 NORTH CAROLINA Environmental Quality August 12th, 2022 Subject: Compliance Evaluation Inspection Permit WQCSD0311 Facility Name: Lake Ridge Aero Park Collection System Durham County Dear Mr. Becker: On August 111, 2022, Josh Brigham of the Raleigh Regional Office conducted a compliance evaluation inspection of the Lake Ridge Aero Park Collection System. The purpose of this inspection was to ensure compliance with the subject collection system permit. During the inspection, the guidance of Wayne Alford, ORC, was greatly appreciated. This compliance evaluation inspection consisted of the following: • Review of the 15A NCAC 02T .0403 permit requirements; • Review of the owner/facility information; • Review of records; and • On -site inspection of the collection system and pump station units. Findings during the pre -inspection file review were as follows: 1. The subject facility is not classified and currently does not have designated operators. 2. The Lake Ridge Aero Park Collection System has had no reported Sanitary Sewer Overflows since the last inspection on October 25, 2018. Findings during the inspection were as follows: 3. The Lake Ridge Aero Park collection system has one pump station that was visited during the inspection. The pump station had secured access and exhibited very little to no waste build-up. The pump station is monitored daily through telemetry and inspected weekly. Inspection records were available on site. The high-water float was used to trigger audio and visual alarms and all functioned normally. No issues were noted. 4. A map of the sewer system was available and contained all required information. 5. The Lake Ridge Aero Park collection system has a Fats, Oils, and Grease Program. Materials are distributed to residents bi-annually. 6. The Lake Ridge Aero Park collection system has one high -priority line. It is inspected regularly and documentation was available. 7. A Spill Response Action Plan was available for review during the inspection. It contained all required information. _E Qr North Carolina Department of Environmental Quality i Division of Water Resources iTH Raleigh Regional Office 1 3800 Barrett Drive I Raleigh, North Carolina 27609 V 919.791.4200 5g- i a.rrr 8. An operation and maintenance plan was available for review. It contained all required information. 9. Four manholes located at the pump station and neighboring area were inspected and no issues were found. If you have questions concerning this report please contact Josh Brigham at 919-791-4251 or joshua.brighamkncdenr.gov. Sincerely, Vanessa E. Manuel, Assistant Region Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ ATTACH ENTs: Compliance Inspection Report Cc: Laserfiche D_E Q-5 North Carolina Department ofEnvironmental Quality I Division of Water Resources 512 North Salisbury Street 1 1611 Mail Service Center I Raleigh, North Carolina 27699-1611 T � 919.707.9000 Compliance Inspection Report Permit: WQCSD0311 Effective: 03/01/00 Expiration: SOC: Effective: Expiration: County: Durham Region: Raleigh Contact Person: Trent Parker Title: Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 08/11/2022 Entry Time 08:30AM Primary Inspector: Joshua S Brigham Secondary Inspector(s): Certification Owner: Aqua North Carolina Inc Facility: Lake Ridge Aero Park CS Phone: 919-467-8712 Phone: Exit Time: 09:30AM Phone: 919-791-4200 Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Deemed permitted collection system management and operation Facility Status: 0 Compliant Not Compliant Question Areas: Miscellaneous Questions General Grease Control Spills/Response Plan Inspections Lines Manholes Pump Stations (See attachment summary) Page 1 of 6 permit: WQCSD0311 Owner- Facility: Aqua North Carolina Inc Inspection Date: 08/11/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: See attached report. Page 2 of 6 permit: WQCSD0311 Owner- Facility: Aqua North Carolina Inc Inspection Date: 08/11/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine General Yes No NA NE # Is this system a satellite system? ❑ ❑ ❑ # If Yes, what is system name or permit number? Is there a overall sewer system map? 0 ❑ ❑ ❑ Does the map include: Pipe sizes M ❑ ❑ ❑ Pipe materials (PVC, DIP, etc) 0 ❑ ❑ ❑ Pipe location 0 ❑ ❑ ❑ # Flow direction 0 ❑ ❑ ❑ # Approximate pipe age 0 ❑ ❑ ❑ # Pump station ID, location and capacity 0 ❑ ❑ ❑ # Force main air release valve location & type ❑ ❑ ❑ # Location of satellite connections ❑ ❑ ❑ Are system maintenance records maintained? 0 ❑ ❑ ❑ Comment: Grease Control Yes No NA NE Is grease/sewer education program documented with req'd customer distribution? 0 ❑ ❑ ❑ # Are other types of education tools used like websites, booths, special meetings, etc? ❑ ❑ ❑ If Yes, what are they? (This can reduce mailing to annual.) For public systems, is there a Grease Control Program via an ordinance/agreement? ❑ ❑ ❑ If Yes, does it require grease control devices at applicable locations? ❑ ❑ ❑ Is the Grease Control Program enforced via periodic inspections/records review? ❑ ❑ ❑ Is action taken against violators? ❑ ❑ ❑ Comment: Spills and Response Action Plan Yes No NA NE # Is system free of known points of bypass? ❑ ❑ ❑ If No, describe type of bypass and location # Have there been any sewer spills in the past 3 years? ❑ ❑ ❑ If Yes, were they reported to the Division if meeting the reportable criteria? ❑ ❑ 0 ❑ If applicable, is there documentation of press releases and public notices issued? ❑ ❑ 0 ❑ Are all spills or sewer related issues/complaints documented? ❑ ❑ 0 ❑ # Are there repeated overflows/problems (2 or more in 12 months) at same location? ❑ ❑ M ❑ # If Yes, is there a corrective action plan? ❑ ❑ 0 ❑ Is a Spill Response Action Plan available? 0 ❑ ❑ ❑ Is a Spill Response Action Plan available for all personnel? 0 ❑ ❑ ❑ Page 3 of 6 Permit: WQCSD0311 Owner- Facility: Aqua North Carolina Inc Inspection Date: 08/11/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Does the plan include: # 24-hour contact numbers ❑ ❑ ❑ # Response time E ❑ D ❑ # Equipment list and spare parts inventory N ❑ ❑ # Access to cleaning equipment 0 ❑ ❑ ❑ # Access to construction crews, contractors, and/or engineers ❑ # Source of emergency funds 0 ❑ ❑ ❑ # Site sanitation and cleanup materials 0 El ❑ ❑ # Post-overflow/spill assessment 0 ❑ ❑ ❑ Comment: No SSOs. Inspections Yes No NA NE Are adequate maintenance records maintained? ❑ ❑ Are pump stations being inspected at the required frequency? ❑ Is at least one complete functionality test conducted weekly per pump station? Is there a system or plan in place to observe the entire system annually? Is the annual inspection documented? ❑ ❑ # Does the system have any high -priority lines/locations? 0 ❑ ❑ El Are inspections of HPL documented at least every 6 months? 0 ❑ ❑ ❑ Are new lines being added to the HPL list when found or created? 13 ❑ El N Comment: Lines/Right-of-Ways/Aerial Lines Yes No NA NE Please list the Lines/Right of Ways/Aerial Lines Inspected: Are right-of-ways and easements maintained for the full width for access? 0 ❑ ❑ If No, give details on temporary access: Is maintenance documented? 0 ❑ ❑ Were all areas/lines inspected free of issues? 0 ❑ ❑ Comment: Manholes Yes No NA NE Please list the Manholes Inspected: Pump station and Sky Lane (3). Are manholes accessible? E El El 0 # Are manhole covers/vents above grade? 0 ❑ El ❑ Are manholes free of visible signs of overflow? 0 ❑ Are manholes free of sinkholes and depressions? 0 ❑ ❑ Are manhole covers present? # Are manholes properly seated? N ❑ ❑ ❑ Page 4 of 6 Permit: WQCSD0311 Owner - Facility:Aqua North Carolina Inc Inspection Date: 08/11/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine # Are manholes in good condition? ❑ # Are inverts in good condition? 11❑ Is flow unrestricted in manholes? E ❑ El ❑ Are manholes free of excessive amounts of grease? 0 ❑ ❑ El Are manholes free of excessive roots? M ❑ ❑ ❑ Are manholes free of excessive sand? M ❑ ❑ ❑ Are manhole vents screened? El ❑ ❑ ❑ Are vents free of submergence? ❑ ❑ 0 Are manholes free of bypass structures or pipes? ❑ ❑ El 0 Comment: Pump Stations Yes No NA NE Please list the Pump Stations Inspected: One pump station. # Number of duplex or larger pump stations in system 1 # Number of vacuum stations in system 0 # Number of simplex pump stations in system 0 # Number of simplex pump stations in system serving more than one building 0 How many pump/vacuum stations have: # A two-way "auto polling" communication system (SCADA) installed? 0 # A simple one-way telemetry/communication system (auto -dialer) installed? 1 For pump stations inspected: Are they secure with restricted access? M El ❑ Were they free of by-pass structures/pipes? 0El ❑ Were wet wells free of excessive grease/debris? ❑ ❑ ❑ # Do they all have telemetry installed? ❑ El ❑ Is the telemetry system functional? 0El El ❑ Is a 24-hour notification sign posted ? 0❑ El 0 Does the sign include: Owner Name? 0 ❑ ❑ Pump station identifier? 0❑ ❑ ❑ # Address? 0❑ ❑ Instructions for notification? 0❑ ❑ ❑ 24-hour emergency contact numbers? 0 ❑ El n Are audio and visual alarms present? 0 0 ❑ Are audio and visual alarms operable? 0 El ❑ ❑ # Is there a backup generator or bypass pump connected? ❑ M Page 5 of 6 permit: WQCSD0311 Owner- Facility: Aqua North Carolina Inc Inspection Date: 08/11/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine If tested during inspection, did it function properly? Is the back-up system tested at least bi-annually under normal operating conditions? # Does it have a dedicated connection for a portable generator? # Is the owner relying on portable units in the event of a power outage? # If Yes, is there a distribution plan? If Yes, what resources (Units/StaffNehicles/etc) are included in Plan? # Does Permittee have the approved percentage of replacement simplex pumps? Is recordkeeping of pump station inspection and maintenance program adequate? Do pump station logs include at a minimum: Inside and outside cleaning and debris removal? Inspecting and exercising all valves? Inspecting and lubricating pumps and other equipment? Inspecting alarms, telemetry and auxiliary equipment? Comment: ❑❑❑M ■❑❑❑ Page 6 of 6