Loading...
HomeMy WebLinkAboutSW6211002_Design Calculations (Riprap)_20220810PROJECT NAME 1649 B&B LOOP LOCATION Raeford, North Carolina Storm Outlet Structure FES No.= TSB #1 SKIMMER Pipe Dia= 2 in Q10 = 0.06 cfs Qfull = 0.06 cfs Vfull = 1.73 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: s Length Storm Outlet Structure FES No.= PO 16 Pipe Dia= 15 in Q10 = 3.14 cfs Qfull = 8.01 cfs Vfull = 6.52 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: s v 3 Length Zone D50 DMAX Riprap Class Apron Thickness Apron Length Apron Width @ Outlet Apron Width @ End Zone D50 DMAX Riprap Class Apron Thickness Apron Length Apron Width @ Outlet Apron Width @ End DATE DESIGN PHASE 11-02-21 PRELIM PROJECT NO CONSTR 1649 REVISION RECORD BY UP OTHER (SPECIFY) CHECKED BY CSB Q10/Qfull = 1.00 V/Vfu I = 1.14 V = 2.0 fps = 1 = 4 in = 6 in = A = 9 in = 0.8 ft = 0.575 ft = 1.0 ft Q10/Qfull = 0.39 V/Vfull = 0.93 V = 6.1 fps = 2 = 8 in = 12 in = B = 18 in = 7.5 ft = 3.75 ft = 8.8 ft 1649 Storm.xlsx LATEST REVISION: 12/1/2021 6:56 AM PAGE 1 OF 3 PROJECT NAME 1649 B&B LOOP LOCATION Raeford, North Carolina Storm Outlet Structure FES No.= PO 12 Pipe Dia= 18 in Q10 = 2.48 cfs Qfull = 10.48 cfs Vfull = 5.92 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: Storm Outlet Structure FES No.= PO 13 Pipe Dia= 18 in Q10 = 1.14 cfs Qfull = 9.02 cfs Vfull = 5.10 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: s Length Zone D5o DMAX Riprap Class Apron Thickness Apron Length Apron Width @ Outlet Apron Width @ End Zone D5o DMAX Riprap Class Apron Thickness Apron Length Apron Width @ Outlet Apron Width @ End DATE DESIGN PHASE PRELIM 11-02-21 PROJECT NO CONSTR 1649 REVISION RECORD BY UP OTHER (SPECIFY) CHECKED BY CSB Q1 o/Qfu I = 0.24 V/Vfu 11 = 0.81 V = 4.8 fps = 2 = 8 in = 12 in = B = 18 in = 9.0 ft = 4.5 ft = 10.5 ft Q1 o/Qfu I = 0.13 V/Vfu11 = 0.68 V = 3.5 fps = 2 = 8 in = 12 in = B = 18 in = 9.0 ft = 4.5 ft = 10.5 ft 1649 Storm.xlsx LATEST REVISION: 12/1/2021 6:56 AM PAGE 2 OF 3 PROJECT NAME 1649 B&B LOOP LOCATION Raeford, North Carolina Storm Outlet Structure FES No.= PO 14 Pipe Dia= 18 in Q10 = 2.37 cfs Qfull = 10.60 cfs Vfull = 5.99 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: Storm Outlet Structure FES No.= PO 15 Pipe Dia= 15 in Q10 = 1.42 cfs Qfull = 8.04 cfs Vfull = 6.54 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: s Length Zone D5o DMAX Riprap Class Apron Thickness Apron Length Apron Width @ Outlet Apron Width @ End Zone D5o DMAX Riprap Class Apron Thickness Apron Length Apron Width @ Outlet Apron Width @ End DATE DESIGN PHASE PRELIM 11-02-21 PROJECT NO CONSTR 1649 REVISION RECORD BY UP OTHER (SPECIFY) CHECKED BY CSB Q1 o/Qfu I = 0.22 V/Vfu11 = 0.78 V = 4.7 fps = 2 = 8 in = 12 in = B = 18 in = 9.0 ft = 4.5 ft = 10.5 ft Q1 o/Qfu I = 0.18 V/Vfu11 = 0.75 V = 4.9 fps = 2 = 8 in = 12 in = B = 18 in = 7.5 ft = 3.75 ft = 8.8 ft 1649 Storm.xlsx LATEST REVISION: 12/1/2021 6:56 AM PAGE 3 OF 3