Loading...
HomeMy WebLinkAboutNCG030716_Monitoring Report_20211119November 18, 2021 North Carolina Department of Environmental Quality DEMLR Stormwater Program 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Subject: Quarterly Stormwater Discharge Monitoring Report Fourth Quarter 2021 PNA Construction Technologies 2027 Gateway Boulevard Charlotte, NC 28208 Certificate of Coverage NCG030716 On behalf of PNA Construction Technologies located at 2027 Gateway Boulevard in Charlotte, NC, Wood Environment & Infrastructure Solutions, Inc. is submitting the attached quarterly stormwater discharge monitoring report (DMR) for the fourth quarter of 2021. Please let us know if you have any questions. Thanks, Chris Case Senior Project Manager Wood E&IS Direct: (704) 357-5577 Mobile: (716) 903-5206 2801 Yorkmont Rd, Suite 100, Charlotte, NC 28208 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0716 Person Collecting Samples: Andrew Frantz, Wood Facility Name: PNA Construction Technologies Laboratory Name: Waypoint Analytical (Chadotte) Facility County: Mecklenburg Laboratory Cert. No.: 37735 Discharge during this period: Yes No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? D Yes No If so, which Tier (I, II, or III)? Tier I A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR Q Yes No Date Uploaded: // ISA Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall001 Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class C N/A Date Sample Collected MM/DD/YYYY 10/28/21 46529 24-Hour Rainfall in inches 0.45 C0530 TSS in mg/L (100 or 50*) 8.9 pH in standard units (6.0-9.0 FW, 00400 6.8-8.5 SW) 6.89 _ < 01119 Copper, total recoverable in mg/L 0.0137 aP4°�7pc �Q (0.010 FW, 0.0058 SW) Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 SW) <0.0005 Zinc, total recoverable in mg/ L (0.126 c" 01094 FW, 0.095 SW) 0 025 Chemical Oxygen Demand (COD) in 00340 mg/L (120) <50 00552 Non -Polar Oil & Grease in mg/L (15) <5.7 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TS5 limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater)SW (Saltwater) Notes (optional): Quarter 4 of 2021 "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, orthose persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and Imprisonment for knowing violations." or Deleeated Authorized Individual CF-Nr9a'ino 0, r?00- 'inc. ocm Email Address 1l- IS- ZI Date MaRp 404- biq Phone Number