Loading...
HomeMy WebLinkAboutNCG030714_Monitoring Report_20220222Stormwater NPDES Permit Data Monitoring Report (DMR) Upload Permit and Facility Information: Please enter tha permit number and other details for this upload t7 _y A �CCn ny�� � O �m IMPORTANT., Until the eDMR system is implemented for DEMLR Stormwater Program permits, an original signed hardcopy of the DMR MUST be mailed to the address in your permit, in addition to this electronic upload. Fields marked with a red asterisk are required. Permit Number* Enter COC or Individual Permit Number (NOT General Permit number with all 0's) NCG030714 Must begin with NCS or NCG Facility Name:* CORMETECH, Inc. County:* Cleveland After uploading here, the original signed hardcopy must be mailed to: DEQ Mooresville Regional Office Attn: DEMLR Stormwater Program 610 East Center Avenue Suite 301 Mooresville. NC 28115 Further contact details at https://deq.nc.gov/contact/regional-offices/mooresville Monitoring Period Information: Monitoring Period What is the YEAR of the sample date(s)? Year:* 2022 Multiple DMRs from sampling periods within the same year can be uploaded together, but please upload different years with a new submittal form. i Also, copies of the lab results and qualitative (visual) monitoring should NOT be submitted unless specifically requested by DEQ staff Only upload the completed and signed DMR forms. DMR Upload* Click the upload button or drag and drop files here to attach document. CORMETECH Q1 2022_Stormwater DMR Signe... 1.77MB Only PDFs are accepted. Comments: 1st Quarter 2022 Stormwater Sampling Results * By checking the box and signing box below, I certify that: a I have given true, accurate, and complete information on this form; o I agree that submission of this Data Monitoring Report (DMR) upload form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); o I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); o I understand that an electronic signature on this upload form has the same legal effect and can be enforced in the same way as a written signature; AND a I intend to electronically sign and submit this DMR upload form. Full Name: * Lanette H Plyler Name of person submitting this form Email Address: * I.plyler@cormetech.com Phone Number:* 9807221811 Signature: * Date: * 02/16/2022 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. -Ifl Certificate of Coverage No. NCG03 0714 Person Collecting Samples: Clinton Rayfield Facility Name: CORMETECH, Inc. Laboratory Name: Pace Analytical Facility County: Cleveland Laboratory Cert. No.: 329 m, Discharge during this period:. Yes 0 No (if no, skip to signature and date) o? Has your facility implemented mandatoryTier response actions this sample period for any benchmark exceedances? s o If so, which Tier (I, II, or III)? Tier 11 aV A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR Date Uploaded: 2/16/2022 In Yes No Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall 001 Outfall 002 Outfall 003 Outfali 004 outran 005 Code N/A Receiving Stream Class Class C Class C Class C Class C Class C N/A Date Sample CollectedMM/DD/YYYY 01/09/2022 01/09/2022 01/09/2022 01/09/2022 01/09/2022 46529 24-Hour Rainfall in inches 0.50 0.50 0.50 0.5 0.5 C0530 TSS in mg/L (100 or 50•) 140 14 22 14 8.5 00400 pH in standard units (6.0-9.0 FW, 6.78 5.88 6.67 6.56 7.03 6.8-8.5 SW) 01119 Copper, total recoverable in mg/L 0.011 0.0056 0.010 <0.005 <0.005 (0.010 FW, 0.0058 SW) 01051 Lead, total recoverable in mg/ L 0.0051 0.0065 0.0033 <0.001 <0.001 0.075 FW, 0.22 SW) 01094 Zinc, total recoverable in mg/ L (0.126 0.032 0.019 0.073 0.041 0.038 FW, 0.095 SW) 00340 Chemical Oxygen Demand (COD) in <20 <20 <20 <20 <20 mg/L (120) 00552 Non -Polar Oil & Grease in mg/L (15) <5.3 <5.3 <5.9 <5.0 <5.6 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): Q1 2022 Quarterly Sampling Results "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." of Permittee or Deleeatiid Authorized Individual l.plyler@cormetech.com Email Address ,�Ih,, Date 980-722-1811 Phone Number NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0714 Person Collecting Samples: Clinton Rayfield Facility Name:CORMETECH, Inc. Laboratory Name: Pace Analytical Facility County: Cleveland Laboratory Cert. No.: 329 Discharge during this period: Yes 0 No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances7 Yes No If so, which Tier (I, II, or w)? Tier II A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR . Yes LjNo Date Uploaded: 2/15/2022 Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter outtall006 Outfall007 outfall Outfall Outfall Code N/A Receiving Stream Class Class C Class C N/A Date Sample Collected MM/DD/YYYY 01 /09/2022 01 /09/2022 46529 24-Hour Rainfall in inches 0.5 0.5 C0530 TSS in mg/L (100 or 50*) 60 <2.5 00400 PH in standard units (6.0-9.0 FW, 6.32 7.09 6.8-8.5 SW) 01119 Copper, total recoverable in mg/L 0.0066 <0.005 (0.010 FW, 0.0058 SW) 01051 Lead, total recoverable in mg/ L <0.001 <0.001 (0.075 FW, 0.22 SW) 01094 Zinc, total recoverable in mg/ L (0.126 0.085 <0.010 FW, 0.095 SW) 00340 Chemical Oxygen Demand (COD) in <20 <20 mg/L (120) 00552 1 Non -Polar Oil & Grease in mg/L (15) <6.2 <5.3 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): Q1 2022 QuarterlySampling Results "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, orthose persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete.) am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." of Permittee or Deleg4ed Authorized Individual l.plyier@cormetech.com Email Address DateI.LILciz � x 980-722-1811 Phone Number