HomeMy WebLinkAboutNCG030706_Monitoring Report_20220621NCDEQ Division of Energy, Mineral and Land Resources
Stormwater Discharge Monitoring Report (DMR) Form for NCG030000
Metal Fabrication
Click here for instructions
Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report a form within
30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DUNTLR, onal Office.
Certificate of Coverage No. NCG03 030706
Person Collecting Samples: Michael Kilpatrick
Facility Name: Greenheck Fan Corporation- TAP
Laboratory Name: Pace Analytical Services
Facility County: Cleveland
Laboratory Cert. No.: 329
Discharge during this period: QYes ® No (if no, skip to signature and date)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? [7Yes 0 No
If so, which Tier (I, II, or III)? Tier I -Zinc
A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR E]Yes Q No
Date Uploaded:
Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red)
Parameter
Parameter
Outfall002
Outfall003
Outfall
Outfall
Outfall
Code
N/A
Receiving Stream Class
Class C
Class C
N/A
Date Sample Collected MM/DD/YYYY
4/5/2022
4/5/2022
46529
24-Hour Rainfall in inches
1.1 Inch
1.1 inch
C0530
TSS in mg/L (100 or 50*)
<2.5
4.0
00400
pH in standard units (6.0-9.0 FW,
6.4
6.0
6.8-8.5 SW)
Copper, total recoverable in mg/L
01119
(0.010 FW, 0.0058 SW)
0.0051
<0.002
Lead, total recoverable in mg/ L
01051
(0.075 FW, 0.22 SW)
<0.002
<0.002
Zinc, total recoverable in mg/ L (0.126
01094
FW, 0.095 SW)
0.660
0.057
Chemical Oxygen Demand (COD) in
00340
mg/L (120)
<20
<20
00552
Non -Polar Oil & Grease in mg/L (15)
<5.0
<5.0
* Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L
FW (Freshwater) SW (Saltwater)
Notes (optional): Outfall 002 was inspected for sources of contamination and public road run-off due containing construction materials may be the source.
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information
submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting
false informatiog_iapluding the possibility of fines and imprisonment for knowing violations."
Signature of Per`inittee or
derek.boyd@greenheck.com
Email Address
Individual
b-IG-Z2
Date
715.841.8366
Phone Number