HomeMy WebLinkAboutNCG030228_Monitoring Report_20220701Alpha EC LLC
4007 NC Hwy 86 N
Hillsborough, NC 27278
24 June 2022
NC DEMLR
Mooresville Regional Office
610 East Center Ave, Suite 301
Mooresville, NC 28115
704-663-1699
.L
�
�Q
.Q
Ref: DMR form for Metal Fabrication — 2nd Quarter Sample 2022
8400054 / Cert of Coverage NCG030228
Pr6formed Line Products
Albemarle (Stanly County) NC
Dear sir/madam:,
Attached please find a completed Metal Fabrication Stormwater DMR form for Preformed Line
Products, Inc, located in Albemarle, NC, for quarterly stormwater sampling performed 23 May 20
as required for compliance with their general permit no. NCG030000, Certificate of Coverage no.
NCG030228. The sampling results demonstrate compliance with permit conditions.
Very Sincerely yours,
Sonya Cato
Environmental Engineer
Alpha EC LLC
scato@alpha-e.us
77
F-7`7
V' I
1
NCDEQ Division of Energy,
gy, Mineral and Lan
Discharge Monitorin d Resources
Metal abr cationDMR) Form for NCG030000
Click here for '
ind submit the DMn instructions
nt this DMR has been uploaded es: electronically via htt �— u' any benchn-,
— edocs.de .nc. ov Forms SW-pMR
NCDEQ Division of Energy, Mineral and Land Resources
Stormwater Discharge Monitoring Report (DMR) Form for NCG030000
Metal Fabrication
Click here for instructions
Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Uploa�m within ,
30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR R lakol Office. '►tl
Certificate of Coverage No. NCG030228
Person Collecting Samples: Ken Helms o
Facility Name: Preformed Line Products
Laboratory Name: Pace Analytical 0
Facility County: Stanly
Laboratory Cert. No.: 37712 / 40
Discharge during this period:
Yes ONo
(if no, skip to signature and date)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Yes MNo
If so, which Tier (I, II, or III)?
A copy of this DMR has been uploaded electronically via h_ttps-./If do s.deg.nc.gov/Forms/SW-DMR Dyes No
Date Uploaded: 06/09/2022
Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red)
Parameter
Parameter
Outfall
Outfall
Outfall
Outfall
Outfall
Code
N/A
Receiving Stream Class
WS-IV
N/A
Date Sample Collected MM/DD/YYYY
05/23/2022
46529
1 24-Hour Rainfall in inches
1.10
C0530
TS5 in mg/L (100 or 50*)
8.6
00400
pH in standard units (6.0 — 9.0 FW,
6.85
6.8-8.5 SW)
Copper, total recoverable in mg/L
01119
(0.010 FW, 0.0058 SW)
<0.02
Lead, total recoverable in mg/ L
01051
(0.075 FW, 0.22 SW)
<0.025
Zinc, total recoverable in mg/ L (0.126
01094
FW, 0.095 SW)
0.0285
Chemical Oxygen Demand (COD) in
00340
mg/L (120)
<25
00552
Non -Polar Oil & Grease in mg/L (15)
<5
* Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HOW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 rag/L
FW (Freshwater) SW (Saltwater)
Notes (optional):
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information
submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting
false ihf rmation,incl ingt possibilityoffines and imprisonment for knowing violations."
Signature of Permittee or Delegated Authorized Individual Date
kh elms@preformed.com
Email Address
704-984-4818
Phone Number
.,a, _
_ .-- r ...- _ _
__ . �
"�- . ��
�,
��