Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0043659_Application (FTSE)_20220809
y July 27, 2022 NCDEQ: Mooresville Regional Office Sanitary Sewer Permitting 610 E. Center Ave. Mooresville, North Carolina 28115 RECEIVED/NCDEQ/DWI AUG - 4 2022 WQROS MOORESVILLE REGIONAL OFFICE RE: Kairoi Clanton — Fast Track Sewer System Extension Application To whom it may concern, The referenced project, "Kairoi Clanton" is a multifamily and single-family development located at 515 Clanton Road, Charlotte, NC 28217. The development consists of a 357-unit multifamily building and 47 townhome lots. The new development will be served by a private sewer that will tie into an existing Charlotte Water 8" sewer main running along the project site on Blairhill Road and Waffle House Drive. The following documents are enclosed: • Application • $480 check • Flow Tracking/Acceptance Form (Charlotte Water) • Capacity Assurance (Charlotte Water) • Site Maps (Aerial and Topographic) • Clanton Road Holdings LP, C/O Kairoi Properties, LLC NC Business License Should you have any questions or concerns regarding the enclosed submittal package, please feel free to contact me directly at (704) 319-5688, or via email at jordan.rosenfeld@kimley-horn.com. Sincerely, KIMLEY HORN AND ASSOCIATES, INC. Jordan Rosenfeld, P.E. Kimley-Horn and Associates, Inc. 200 South Tryon Street, Suite 200 Charlotte, NC 28202 Direct: (704) 319-5688 Mobile: (704) 989-4757 jordan.rosenfeld@kimley-horn.com re± r com 2001641101170701Street Sun200, Ch rlot C 28202 14�333�5131 Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 06-21 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) RE( All items must be completed or the application will be returned I. APPLICANT INFORMATION: IVED/NODE®/DWR 1. Applicant's name: Clanton Road Holdings, LP (company, municipality, HOA, utility, etc.EVIl. REG QNgL OFFFI 2. Applicant type: ❑ Individual ❑ Corporation ® General Partnership ❑ Privately -Owned Public ut1it' ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Daniel W. Zunker Title: General Partner 4. Applicant's mailing address: 711 Navarro Street, Suite 400 City: San Antonio State: TX Zip: 78205- 5. Applicant's contact information: Phone number: (512) 999-8823 Email Address: apollard@kairoi.com per 15A NCAC 02T .0106(b) II. PROJECT INFORMATION: 1. Project name: Kairoi Clanton 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.196° Longitude: -80.881 ° 5. Parcel ID (if applicable): 145-133-04 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Jordan Rosenfeld License Number: 054439 Firm: Kimley-Horn Mailing address: 200 South Tryon Street, Suite 200 City: Charlotte State: NC Zip: 28202- Phone number: (704) 319-5688 Email Address: jordan.rosenfeld(E Kimley-Horn.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek Permit Number: NC0024970, NC0024945, NC0024937 Owner Name: Charlotte Water V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ 2. Downstream (Receiving) Sewer Information: inch ❑ Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): FORM: FTA 06-21 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑ No N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑ No ® N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): Residential (Individually Owned) ❑ Retail (stores, centers, malls) ® Residential (Leased) ❑ Retail with food preparation/service ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Food and drink facilities ❑ Church ❑ Businesses / offices / factories ❑ Nursing Home ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool/Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic % Commercial % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ® No > If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a,b No. of Units Flow Multi -Family Residential 135 gal/unit 357 48,195 GPD Single -Family Residential 190 gal/household 47 8,930 GPD Pool 10 gal/person 400 4,000 GPD gal/ GPD gal/ GPD gal/ GPD Total 61,125 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 61,125 GPD (per 15A NCAC 02T .0114) > Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 657 PVC 8 320 DI > Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - . 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) > This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C.1.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump > Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B): > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: > Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(f) & (g)? 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer system ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches 2Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 2Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class H impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305(f) or (g), see Section X.1 of this application *15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage 2. Does this project comply with the minimum separation requirements for water mains? ❑ Yes ❑ No ® N/A > If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ❑ Yes ❑ No N/A > Please provide supplementary information identifying the areas of non-conformance. > See the Division's draft separation requirements for situations where separation cannot be met. > No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: ® No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No > This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? > Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the project, the full technical review is required. 2. Professional Engineer's Certification: I, Jordan H. Rosenfeld , attest that this application for Kairoi Clanton (Professional Engineer's name from Application Item III.1.) (Project Name from Application Item II. I ) has been reviewed by me and• is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting, of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NO01.51d.tr/0)), North Carolina Professional Engineer's seal, signature, and date: �OQ �s,SSI0�� ' 2•4. SEAS- r• 4 054435 o vO�Oq • INjO..4(41 MO 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, • '1rsiK.0 , attest that this application for (Signature Authority Name from Application Item I.3.) �J3J2Plt (Project Name from Application Item 11.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: y f� FORM: FTA 06-21 Page 5 of 5 State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Kimley-Horn Project Name for which flow is being requested: Kairoi Clanton (Residential) More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek b. WWTP Facility Permit #: NC0024970, NC0024945, NC0024937 All flows are in MGD c. WWTP facility's permitted flow 99.00 d. Estimated obligated flow not yet tributary to the WWTP 14.688 e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 65.767 0.061125 80.455 81.3% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Clanton Road Downstream Permit Number: Unknown Page 1 of 2 FTSE 10-18 III. Certification Statement: Keri Cantrell certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under noinial circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Digitally signed by Keri Cantrell Date: 2022.07.19 10:27:11 -04'00' 7/19/2022 Adobe Acrobat version: 2022.001.20117 Signing Official Signature Date Chief Engineer Title of Signing Official Page 2 of 2 FTSE 10-18 CHARLOTTE June 27, 2022 Mr. Jordan Rosenfeld Kimley-Horn 200 South Tryon Street Suite 200 Charlotte, NC 28202 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE KAIROI CLANTON 515 CLANTON ROAD, CHARLOTTE, NC 28217 CLTWATER TRACKING# 20223976 After an analysis of the sanitary sewer associated with the proposed design of project, 20223976, KAIROI CLANTON, it was determined that there is sufficient capacity to accommodate the proposed sewer flow of 61,125 gallons per day (357 units x 135 gpd/unit; 47 units x 190 gpdlunit; 400 people x 10 gpd/person) at the connection point(s) indicated on the submitted utility plan for transmission to the Irwin Creek Wastewater Treatment Plant; NPDES permit number NC0024945, for treatment. This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works. Please see attached NCDEQ-FTSE form. Charlotte Water (CLTWater) agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow. The applicant should understand that due to the involvement of other agencies and continuing growth of the water system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct or extend private water or sewer systems, as the appropriate local or State permits are required prior to construction. If the appropriate authorization to construct permits are not obtained, construction has not started within two (2) years of issuance of this flow acceptance, and payment for any service connections have not been received within two (2) years of issuance of this flow acceptance Letter, this flow acceptance approval shall be rescinded, and a new flow acceptance request must be made. The CAP analysis performed determines available capacity within the existing public gravity sewer system. The developer is responsible for any additional private or public sewer infrastructure required to convey flow from the proposed development to the existing public gravity sewer. If you have any questions, please do not hesitate to contact me at (704) 432-5801. Sincerely, w,uerwt.o- Avvzo-la• Guillermo Anzola / Engineering Assistant CHARLOTTE WATER P: 704-432-5801 / charlottewater.orq Charlotte Water 5100 Brookshire Blvd, Charlotte, NC 28216 charlottewater.org Operated by the City of Charlotte AERIAL MAP KAIROI CLANTON SITE AUGUST 2021 Kimley») Horn NC LICENSE MF-0102 ©202/ 20D SOUTH TRYON STREET, SURE 200 CHARLOTTE, NORTH CPROLINA28202 PHONE701-3335131 THIS DOCUMENT. 1t tTHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT CF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER REUANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADAPTATION SY KIMLEY-HORN AND ASSOCIATES, INC. SHALL BE WITHOUT UABIUTY TO KIMLEY-HORN AND ASSOCIATES, INC. USGSU.S. DEPARTMENTU.S. GEOLOGICAL SURVEY INTERIOR M M.unMvty p�vr Topo CHARLOTTE WEST QUADRANGLE NORTH CAROLINA • MECKLENBURG COUNTY 7.5-MINUTE SERIES tag Gana a tola ®. VOW, 0.P.k,M CHARLOTTE WEST, NC 2019 wUV' ,s two stso SOSID: 2433014 Date Filed: 6/10/2022 11:39:00 AM Elaine F. Marshall North Carolina Secretary of State C2022 153 01803 State of North Carolina Department of the Secretary of State APPLICATION FOR REGISTRATION AS A FOREIGN LIMITED PARTNERSHIP Pursuant to §59-902 of the General Statutes of North Carolina, the undersigned hereby submits this application for Registration as a Foreign Limited Partnership for the purpose of obtaining a Certificate of Authority to transact business in this State. 1. The name of the foreign limited partnership is: Clanton Road Holdings, LP 2. If the name of the foreign limited partnership is unavailable for use in the State of North Carolina, the name the limited partnership wishes to use is: (The name must contain the words "Limited Partnership," or the abbreviation "L.P." or "LP," or the combination "Ltd. Partnership".) 3. The jurisdiction in which the limited partnership was formed is Texas and the date of formation was April 11, 2022 The limited partnership's period of duration is perpetual 4. The street address of the principal office is: 711 Navarro Street, Suite 400 Number and Street: San Antonio TX 78205 Bexar City: State: Zip Code: County: The mailing address, if different from the street address, of the principal office: Telephone: Number and Street: City: State: Zip Code: County: 5. Name of Registered Agent: C T Corporation System 6. Address of Registered Agent's Office: 160 Mine Lake Ct., Ste. 200 Number and Street: Raleigh 27615-6417 Wake City: State: NC Zip Code: _ County: The mailing address, if different from the street address, of the registered office: Number and Street: City: State: NC Zip Code: _ County: NOTES: Filing fee is $50. This document must be filed with the Secretary of State. BUSINESS REGISTRATION DIVISION (Revised August, 2017) 4C046 - t ti9/2017 Wolters Kluwer Online P.O.BOX 29622 Page 1 RALEIGH, NC 27626-06222 Form. LP-04 7. In consideration of the issuance of a Certificate of Authority to transact business in North Carolina, the limited partnership appoints the Secretary of State of North Carolina as the agent to receive service of process, notice or demand, whenever the foreign limited partnership fails to appoint or maintain a registered agent in this State, or whenever such registered agent cannot with reasonable diligence be found at the registered office. 8. (Optional): Please provide a business e-mail address: The Secretary of State's Office will e-mail the business automatically at the address provided at no charge when a document is filed. The e-mail provided will not be viewable on the website. For more information on why this service is being offered, please see the instructions for this document. 9. Enter the name and address of each general partner: (attach additional sheets if necessary) Name KDP GP LLC Name Street/No. 711 Navarro Street, Suite 400 _ Street/NO. City San Antonio City Texas 78205 State/Zip — _ — — 10. Limited Partners (select 1 or 2, as appropriate) El Attached is a list of the names and addresses of all limited partners (include full name/street address/city/state/zip code/county); or ❑ The location of the office where list of the names and addresses of the limited partners and their capital contributions will be kept as long as the limited partnership transacts business in North Carolina is: Number and Street: City: State: Zip Code: County: 11. (Select one) IJ The foreign limited partnership is a foreign limited liability limited partnership. 0 The foreign limited partnership is not a foreign limited liability limited partnership. 12. This registration will be effective upon filing, unless a future date and/or time is specified: NOTES: Filing fee is 550. This document must be filed with the Secretary of State. Daniel W. Linker Typed or printed name Signature Authorized Representative for KDP GP LLC, Title Its General Partner BUSINESS REGISTRATION DIVISION (Revised August, 2017) NC046 1I/9/2017 Wolters Kluwer Online P.O.BOX 29622 Page 2 RALEIGH, NC 27626-06222 Form LP-04 Attachment - Limited Partners Clanton Road Holdings, LP Entity Name Name of Limited Partner Address (include street address, city, state zip and county) PBVI — Clanton Road Holdings, LP a Texas limited partnership 3800 North Lamar Blvd., Suite 350 Austin, Texas 78756 KDP Clanton Road Holdings, LP, a Delaware limited partnership c/o Kairol Residential 711 Navarro Street, Suite 400 San Antonio, TX 78205 KDP Clanton Road Promote, LP, a Delaware limited partnership c/o Kairol Residential 711 Navarro Street, Suite 400 San Antonio, TX 78205