Loading...
HomeMy WebLinkAboutNC0028711_Wasteload Allocation_19920514NPDES DOCIMENT SCANNING COVER SHEET NC0028711 Berryhill Elementary WWTP NPDES Permit: Document Type: Permit Issuance .-V:steload Allocation Authorization to Construct (AtC) Permit Modification Complete File - Historical Correspondence Speculative Limits Instream Assessment (67b) Environmental Assessment (EA) Permit History Document Date: May 14, 1992 This document is printed on reuse paper - ignore any content on the reYer to side NPDES WASTE LOAD ALLOCATION PERMIT NO.: NC0028711 PERMITTEE NAME: Charlotte -Mecklenburg Schools FACILITY NAME: Berryhill Elementary School Facility Status: Existing Permit Status: Renewal Major Minor Pipe No.: 001 Design Capacity: 0.006 MGD Domestic (% of Flow): 100 % Industrial (% of Flow): Comments: Refer : Basinwide / Streamline WLA File Completed By Permits & Engineering At Front Of Subbasin RECEIVING STREAM: Lake Wylie Class: WS-III and B Sub -Basin: 03-08-34 Reference USGS Quad: G15NW (please attach) County: Mecklenburg Regional Office: Mooresville Regional Office Previous Exp. Date: 12/31/92 Treatment Plant Class: 1 Classification changes within three miles: No change within three miles. Requested by: Mack Wiggins Prepared ater Reviewed by: (.- 44, wQL\ c-A- Date: 10/17/91 Date: S,i, /g z- Date: E /a-n Modeler Date Rec. # 3-1A lolztl9t (0530 Drainage 1�rea (mi2 ) 7 Avg. Streamflow (cfs): '�• 3 7Q10 (cfs) D. b Winter 7Q10 (cfs) O. i 5 30Q2 (cfs) D. i S' Toxicity Limits: IWC % Acute/Chronic Instream Monitoring: Parameters .1 . 1'C c c& Upstream t CIO I u„� ,. Location Downstream jnv( Ati@iLocation Effluent Characteristics Summer Winter BOD5 (mg/1) 17 17 NH3-N (mg/1) o 9 D.O. (mg/1) O o . 0 TSS (mg/1) ® 3 a F. Col. (/100 ml) 2-t9 o pH (SU) c —? (^ ? ge-S L IJ 0444A (N 11) IVOIk. sitv" ,....y.„..,4,--- i A rr Comments: UNITED STATES DEPARTMENT OF THE INTERIOR GEOLOGICAL SURVEY 5oroomt GASTONIA 15 MI. 3 MI. TO N.C. 273 57'30" 3 , cIL;t CA P 151 J Facility Name: NPDES No.: Type of Waste: Facility Status: Permit Status: Receiving Stream: Stream Classification: Subbasin: County: Regional Office: Requestor: Date of Request: Topo Quad: FACT SHEET FOR WASTELOAD ALLOCATION Berryhill Elementary School NC0028711 Domestic - 100% Existing Renewal Lake Wylie WS-III and B 03-08-34 Mecklenberg Mooresville Regional Office &r� Mack Wiggins 10/21/91 G15NW Request # litchtlEIPT. O5 F.SOi'RCES AND COM!►tL'N 1TY DEVELOIPISOfrf APR 1 1992 ,�VOQRESYIoo or KLLE �c� RI6WNAL UM. Stream Characteristic: USGS # Date: Drainage Area (mi2): Summer 7Q10 (cfs): Winter 7Q10 (cfs): Average Flow (cfs): 30Q2 (cfs): IWC (%): 1987 WLA 2.07 0.0 0.15 2.3 0.15 100 l_J Wasteload Allocation Summary (approach taken, correspondence with region, EPA, etc.) Instream data shows no consistant instream DO problems. Special Schedule Requirements and additional comments from Reviewers: Recommended by: L ,,,f =c1�— Date: 3.2c -.9 Z Reviewed by Instream Assessment: Regional Supervisor: /WC Permits & Engineering: / Date: Date: 5 Date:. - RETURN TO TECHNICAL SERVICES BY: APR 2 5 1992. 2 Fxisting Limits: CONVENTIONAL PARAMETERS Monthly Average Summer Winter Wasteflow (MGD): 0.006 0.006 BOD5 (mg/1): 17 17 NH3N (mg/1): 9 9 DO (mg/1): 5.0 5.0 TSS (mg/1): 30 30 Fecal Co1. (/100 ml): 200 200 pH (SU): 6.0-9.0 6.0-9.0 Residual Chlorine (µg/1): monitor monitor Oil & Grease (mg/1): TP (mg/1): TN (mg/1): Recommended Limits: Monthly Average Summer Winter WQ or EL Wasteflow (MGD): 0.006 0.006 BOD5 (mg/1): 17 17 NH3N (mg/1): 9 9 DO (mg/1): 5.0 5.0 TSS (mg/1): 30 30 Fecal Co1. (/100 ml): 200 200 pH (SU): 6.0-9.0 6.0-9.0 Residual Chlorine (µg/1): monitor monitor Oil & Grease (mg/1): TP (mg/1): TN (mg/1): Limits Changes Due To: Parameter(s) Affected Change in 7Q10 data Change in stream classification Relocation of discharge Change in wasteflow Other (onsite toxicity study, interaction, etc.) Instream data New regulations/standards/procedures New facility information X Parameter(s) are water quality limited. For some parameters, the available load capacity of the immediate receiving water will be consumed. This may affect future water quality based effluent limitations for additional dischargers within this portion of the watershed. OR No parameters are water quality limited, but this discharge may affect future allocations. 3 INSTREAM MONITORING REQUIREMENTS Upstream Location: 100 feet upstream of discharge point Downstream Location: 200 feet downstream of discharge point Parameters: Temperature, DO, Fecal Coliform , CondOLk y, Special instream monitoring locations or monitoring frequencies: MISCELLANEOUS INFORMATION & SPECIAL CONDITIONS Adequacy of Existing Treatment Has the facility demonstrated the ability to meet the proposed new limits with existing treatment facilities? Yes No If no, which parameters cannot be met? Would a "phasing in" of the new limits be appropriate? Yes No If yes, please provide a schedule (and basis for that schedule) with the regional office recommendations: If no, why not? Special Instructions or Conditions Wasteload sent to EPA? (Major) (Y or N) (If yes, then attach schematic, toxics spreadsheet, copy of model, or, if not modeled, then old assumptions that were made, and description of how it fits into basinwide plan) Additional Information attached? (Y or N) If yes, explain with attachments.