Loading...
HomeMy WebLinkAboutSW6220201_Plansheet - SCM Detail_20220510 (9)z rr �11/2rr 3'-611 0¢ 1 Q ' 5 rr 1" DEPRESSION �\ 15/8rr 1/2 �i�1�/g" F Li_J�CD 1 7�8 1 7/g T F-9-H 00ULLI Cr FG o LL �1 G E i E Q'_cc0 CD N \ o �- --- I --� ~ oza C� �- --- -1---- Lu OH O = H I o N I 0 O= N O i Z H O CL H LLI _N I�H I o0 SECTION G-G M F-� PLAN OF FRAME 1 ' - 75/8 1 ' - 75/8" CAST IRON O PLAN OF GRATING W O � ~ O 2r_31/'r CAST IRON Ow Q O tZ-t Q T Z O 1/8 rr 1/8 rr 1/8 rr 1/8 rr cr Q � 0 W 1 rr 1 rr 1 rr 1 " Cn 3'-33/4r' 2'_33/„ _ aCD 1 16 rr 2 rr 1/8 r' 1/8 rr 1/8 rr 1/8 rr z U_ O 3� „ 3� rr I I -3/4 rr 3� rr I p SECTION H - H 3,_2„ 2r_Cn 2„ I� Q LU Z 0 M H 21/8 21/8 o a 3'-13/4" N N 2r_13�rr N N = O w 3'-611 2'_611 0 CJ O LL SECTION E-E SECTION F-F SHEET 1 OF 1 840.16 z GENERAL NOTES: O � Y MORTAR JOINTS 1/2" +/ - 1/8" THICK. % USE CLASS "B" CONCRETE THROUGHOUT. Q < USE FORMS FOR CONSTRUCTION OF THE BOTTOM SLAB. H = CD USE 0 USE #4 BAR DOWELS AT 12" CENTERS. LL _J d H Z O O O = X }X DEDUCT FOR PIPE(S) FROM TOTAL CU. YDS. OF BRICK MASONRY. Cr Z ^ - - J ONOVIDE ALL CENTER. USE CSTEPS IWHICH NS ECOMP Y WITH STD. DRAWING R 3'-6" IN DEPTH WITH E 840.66. Q PS 12" Lu U O - - - -4 - - - USE BRICK OR CONCRETE BLOCK WHICH COMPLIES WITH THE REQUIREMENTS _ ~ Z w OF SECTION 840 OF THE STANDARD SPECIFICATIONS. O LL OH J t IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB O 0 O AS SHOWN ON STD. NO. 840.00. Z r""r FOR 8'-0" IN HEIGHT OR LESS, USE 8" WALL. OVER 8'-0" IN HEIGHT, USE 00 H 12" WALL TO 6'-0" FROM TOP OF WALL AND 8" WALL FOR THE REMAINING *- w CL 0 I 6'-0". QUANTITES TO BE ADJUSTED ACCORDINGLY. Lu Y t CONSTRUCT WITH PIPE CROWNS MATCHING. r PLAN SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES. WITH COPING REMOVED DO NOT USE BRICK MASONRY DROP INLET IN LOCATIONS SUBJECT TO TRAFFIC. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. F PLAN uur1Nu killblUrNIAL) TOP ELEVATION STD. 840.16 RAME AND GRATE TE SECTION X-X v ON MIN. HEIGHT, H) 8" B 8" 0 I I I T #4 BAR MAX. PIPE THIS SIDE - 18"' SECTION Y-Y 6"6I I DEDUONEIPIpEFOR DOWEL DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED DIMENSIONS OF BOX & PIPE CUBIC YARDS CUBIC YARDS PIPE SPAN WIDTH MIN. HEIGHT CONCRETE BRICK MASONRY BOTTOM WALL PER TOTAL BRICK D A B H SLAB FOOT HT • MASONRY FOR C. S . R . C. MIN. HEIGHT, H 12" 3'-0" 2'-0" 2'-0" 0.268 0.313 0.522 0.020 0.032 15" 2'-3" 0.268 0.313 0.600 0.031 0.047 18" 2'-6" 0.268 0.313 0.678 0.044 0.065 24" 3'-0" 0.268 0.313 0.835 0.078 0.113 30" 3'-0" 2'-0" 3'-6" 0.268 0.313 0.991 0.122 0.170 \L MANHOLE E C L r _ ¢- Cn r � OL s� y �\ /3„:i.- ch D.54 C FOR MANHOLE COVER & FRAME #4 BARS "A" OPTIONAL SPACED 6" C. TO C. BRICK MAY BE USED TO ADJUST FRAME & COVER TO SURFACE ELEVATION MAX. 1' 1/ " rn - - L OUTLET PIPE INLET PIPE 6" SECTION X-X 6" 1/ „ 6" 6" SECTION Y-Y E OR F 1 %2" SECTION C-C OR D-D GENERAL NOTES: CHAMFER ALL EXPOSED CORNERS 1". USE CLASS "B" CONCRETE THROUGHOUT. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS TO CONSTRUCT THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF BOX, ADD TO BASE AS SHOWN ON STANDARD NO. 840.00. PROVIDE ALL JUNCTION BOXES OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTERS IN ACCORDANCE WITH STD. NO. 840.66. ADJUST THE STEEL, CONCRETE AND BRICK MASONRY QUANTITIES TO INCLUDE THE ADDITION OF THE MANHOLE (I.E. DIAGONAL BARS SHORTENED AROUND OPENING IN TOP SLAB, ADDITIONAL VARIABLE HEIGHT BRICK MASONRY, OPENING IN TOP SLAB.) MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP ELEVATION IS 12 FEET. #4 BAR r J 6"�I DOWEL DIMENSIONS AND QUANTITIES FOR CONCRETE JUNCTION BOXES \L MANHOLE E C L r _ ¢- Cn r � OL s� y �\ /3„:i.- ch D.54 C FOR MANHOLE COVER & FRAME #4 BARS "A" OPTIONAL SPACED 6" C. TO C. BRICK MAY BE USED TO ADJUST FRAME & COVER TO SURFACE ELEVATION MAX. 1' 1/ " rn - - L OUTLET PIPE INLET PIPE 6" SECTION X-X 6" 1/ „ 6" 6" SECTION Y-Y E OR F 1 %2" SECTION C-C OR D-D GENERAL NOTES: CHAMFER ALL EXPOSED CORNERS 1". USE CLASS "B" CONCRETE THROUGHOUT. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS TO CONSTRUCT THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF BOX, ADD TO BASE AS SHOWN ON STANDARD NO. 840.00. PROVIDE ALL JUNCTION BOXES OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTERS IN ACCORDANCE WITH STD. NO. 840.66. ADJUST THE STEEL, CONCRETE AND BRICK MASONRY QUANTITIES TO INCLUDE THE ADDITION OF THE MANHOLE (I.E. DIAGONAL BARS SHORTENED AROUND OPENING IN TOP SLAB, ADDITIONAL VARIABLE HEIGHT BRICK MASONRY, OPENING IN TOP SLAB.) MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP ELEVATION IS 12 FEET. #4 BAR r J 6"�I DOWEL DIMENSIONS AND QUANTITIES FOR CONCRETE JUNCTION BOXES DIMENSIONS OF BOX AND PIPE REINFORCEMENT BARS "A" TOP SLAB DIMENSIONS CUBIC YARDS IN BOX TOTAL QUANTITIES BOX AND SLABS DEDUCTIONS FOR ONE PIPE CU.YDS. PIPE SPAN WIDTH HEIGHT D A B H N0. LENGTH E F TOP SLAB BOTTOM SLAB WALL/ FT. OF HT, LBS. REINF CU. YDS. MIN. "H" C.S. R.C. 12" 2'-0" 2'-0" 2'-3" 12 2'-9" 3'-0" 3'-0" 0.167 0.167 0.185 22 0.750 0.015 0.024 15" 2'-3" 2'-3" 2'-6" 12 3'-0" 3'-3" 3'-3" 0.196 0.196 0.204 24 0.902 0.023 0.036 18" 2'-6" 2'-6" 2'-9" 14 3'-3" 3'-6" 3'-6" 0.227 0.227 0.222 30 1.065 0.033 0.049 24" 3'-0" 3'-0" 3'-3" 16 3'-9" 4'-0" 4'-0" 0.296 0.296 0.259 40 1.434 0.059 0.085 30" 3'-6" 3'-6" 3'-9" 18 4'-3" 4'-6" 4'-6" 0.375 0.375 0.296 51 1.860 0.092 0.127 36" 4'-0" 4'-0" 4'-3" 20 4'-9" 5'-0" 5'-0" 0.463 0.463 0.333 64 2.341 0.132 0.178 42" 4'-6" 4'-6" 4'-9" 22 5'-3" 5'-6" 5'-6" 0.560 0.560 0.370 77 2.878 0.180 0.243 48" 5'-4" 5'-4" 5'-3" 26 6'-3" 6'-4" 6'-4" 0.743 0.743 0.407 111 3.623 0.235 0.317 54" 5'-10° 5'-10" 5'-9" 28 6'-7" 6'-10" 6'-10" 0.865 0.865 0.444 126 4.283 0.297 0.401 60" 6'-6" 6'-6" 6'-3" 30 7'-3" 7'-6" 7'-6" 1.042 1.042 0.481 145 5.090 0.367 0.495 66" 7'-1" 7'-1" 6'-9" 32 7'-10" 8'-1" 8'-1" 1.210 1.210 0.518 169 5,917 0.444 0.589 M ~ W w J CL = f••1 CL o i0. O Cr O M Q O Z � � H � ~ CA Ci - } M N T om Q O _ HEET 1 OF 1 840.15 z O Cf) H Q Q HF- CC: 8U LL _j IL O O O = wQZLL ^ Q U Er 0 H H C0 LL 0 cc I 00(ncr Z H 1 0 IL H wo r � Cr O x LL O LU 0 COJ z O w O z N Q cc o � J 0z<(0 z oo Z < W p W = cv Q V F~-i T Q O O = SHEET 1 OF 1 840.31 '" WEEP HOLES J PLAN WITH GRATE & FRAME REMOVED BRICK COPING(INCIDENTAL) TOP ELEVATION v STD. 840.16 FRAME - & GRATE I 6" A 6" 6" I I M (o SEE NOTE DOWEL(SEE NOTE) SECTION X - Xno GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL DROP INLETS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR 2" KEYWAY OR #4 BAR DOWELS AT 12 CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. CONSTRUCT WITH PIPE CROWNS MATCHING. SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES NOT SHOWN. INSTALL 2" WEEPHOLES AS DIRECTED BY THE ENGINEER. INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF NO. 78M STONE IN A POROUS FABRIC BAG OR WRAP, AT EACH WEEP HOLE OR AS DIRECTED BY THE ENGINEER. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. #4 BAR B 6" N I 6„ I DOWEL MAX. PIPE THIS SIDE - 18" SECTION Y-Y DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX & PIPE CUBIC YARDS CONC. IN BOX DEDUCTIONS FOR ONE PIPE PIPE SPAN WIDTH MIN. HEIGHT D A B H BOTTOM SLAB WALL PER FT. HT, TOTAL NGRETE cOMINIMUM FGR MINIM HEIGHT, H C.M. R.C. 12" 3'-0" 2'-0" 2'-0" 0.222 0.222 0.592 0.015 0.026 15" 2'-3" 0.648 0.023 0.036 18, 2'-6" 0.703 0.033 0.049 24" 3'-0" 0.814 0.059 0.085 30" 3'-0" 2'-0" 3'-6" 0.222 0.222 0.925 0.092 0.127 TYPE 1 OR TYPE 3 MARKERS FOR OBSTRUCTIONS WITHIN THE ROADWAY SIGN TYPICAL APPLICATION OF TYPE 1 OR TYPE 3 OBJECT MARKERS IS THE DELINEATION OF SIGN SUPPORTS OR RAISED ISLANDS. TYPE 1 OBJECT MARKER SHOWN RAISED ISLAND 4' MIN. TRAVELWAY TYPE 4 MARKERS FOR END OF ROADWAY 3 MARKERS MINIMUM 6' TYP. 6' TYP. TYPE 2 OR TYPE 3 MARKERS FOR OBSTRUCTIONS ADJACENT TO THE ROADWA` BRIDGE TWO LANE ROADWAY HAZARD AREA OVERHEAD BRIDGE s CULVERT o� TYPICAL APPLICATIONS OF TYPE 2 OR TYPE 3 OBJECT MARKERS INCLUDES DELINEATION OF BRIDGE PIERS, ABUTMENTS, HANDRAILS, CULVERT HEADWALLS, NARROW SHOULDERS, DROP-OFFS, OR OTHER UNDESIRABLE CONDITIONS WHEN GUARDRAIL OR OTHER ROADSIDE PROTECTION IS NOT IN PLACE. )NAL MANHOLE P LAN SEE STANDARD 840.54 FOR MANHOLE COVER & FRAME OPTIONAL BRICK MAY BE USED TO ADJUST FRAME & COVER 6" TO SURFACE ELEVATION MAX. 1 1/ „ 0)OUTLET PIPE � I E 1 C QLU UO ma i V U) U _ Cl) C#4 BARS 10 SPACED 6" C. TO C. A I I I p• I 13+16" I 6„ OUTLET ELEVATION SECTION X-X SEE STANDARD 840.54 FOR MANHOLE COVER & FRAME BRICK MAY BE USED TO ADJUST FRAME & COVER 6„ TO SURFACE ELEVATION MAX. 1' 1/4" X 8" EXP. JOINT o .• X 1/ „ 9 6" 1 x B 3" DOWEL SECTION Y-Y 7' U-CHANNEL POSTS (1.12 LB/FT) PAVEMENT z oCf) �} Q Q LL__JCHZ 00C/5= uj < LL = Q U 00 (n�w0J rr O 0 cn Q z H= H > Lu w C1 � r Q O LL W CD J fZ-t z w CL Q ~ H CL 0 C- O o 0 IBC � Q�� Z W = C W _ >- 1= N Q z 0 O 0 SHEET 1 OF 1 840.14 z O cn H } Qa H = (D LLJHZ O 0 O = = Z ^ w Q LL = Q U 0 0 H (nw H0J 0 0 (n Z H �1--I w O � 0 TYPE 3 OBJECT MARKER = MOUNTED ON U-POST O LL 0 z N E. 0. H Ili 1! 4' MIN. _ � O � � H TRAVELWAY cc FE J J REAR OF SIGN IN MEDIAN (, H W Cl) (n � H TYPE 2 OBJECT MARKER >_ 0 MOUNTED TO SIGN POST < O 0 4' MIN. 1' O _ TRAVELWAY TRAVELWAY MEDIAN LEGEND F- OBJECT MARKER « DIRECTION OF M TRAFFIC FLOW SHEET 1 OF 1 1264.02 GENERAL NOTES: Z CHAMFER ALL EXPOSED CORNERS 1". OH >_ USE CLASS "B" CONCRETE THROUGHOUT. F- Q USE #4 BAR DOWELS AT 12" CENTERS. Q F- MORTAR JOINTS 1/2" ± 1/g" THICK. H = C'3 U CONCAVE TOO ALL EXPOSED JOINTS. 0O JO fL = Z USE FORMS TO CONSTRUCT THE BOTTOM SLAB. w = Z LL ^ JUMBO BRICK WILL BE PERMITTED. CONCRETE BRICK OR 4" H U O SOLID CONCRETE BLOCKS MAY BE USED IN LIEU OF CLAY BRICK. < _ F- Z H FOR 8'-0" IN HEIGHT OR LESS, USE 8" WALL. OVER 8'-0" IN Cn H LL 0 J HEIGHT, USE 12" WALL TO 6'-0" FROM TOP OF WALL, AND 8' WALL H FOR THE REMAINING 6'-0". ADJUST DIMENSIONS AND QUANTITIES z O H = ACCORDINGLY. '> 00 H IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF BOX, 00 � ADD TO BASE AS SHOWN ON STANDARD NO. 840.00. w T PROVIDE ALL JUNCTION BOXES OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTERS IN ACCORDANCE WITH STD. NO. 840.66. ADJUST THE STEEL, CONCRETE AND BRICK MASONRY QUANTITIES TO INCLUDE THE ADDITION OF THE MANHOLE (I.E. DIAGONAL BARS SHORTENED AROUND OPENING IN TOP SLAB, ADDITIONAL VARIABLE HEIGHT BRICK MASONRY, OPENING IN TOP SLAB.) MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP ELEVATION IS 12 FEET. _ O #4 BAR LL x '^ N CD O Lu Z CO O w H = � 6" E OR F 11/2 Z H Q z Q SECTION 6� o N M _ C-C OR D-D DOWEL v Q DIMENSIONS AND QUANTITIES FOR BRICK JUNCTION BOXES DIMENSIONS OF BOX AND PIPE REINFORCEMENT BARS TOP SLAB DIMENSIONS CUBIC YARDS DEDUCTIONS FOR ONE PIPE CU.YDS. PIPE SPAN WIDTH HEIGHT CONC. BRICK MASONRY D A B H NO. LENGTH E F TOP & BOTTOM CU. YD. MIN. HEIGHT CU. YD. WALL PER FT. HT. CU. YD. C.S. R.C. 12" 2'-0" 2'-0" 2'-3" 12 3'-1" 3'-4" 3'-4' 0.412 0.591 0.263 0.020 0.032 15" 2'-0" 2'-0" 2'-6" 12 3'-1" 3'-4" 3'-4" 0.412 0.657 0.263 0.031 0.047 18" 2'-4" 2'-4" 2'-9" 14 3'-5" 3'-8" 3'-8" 0.498 0.814 0.296 0.044 1 0.065 24" 3'-0" 3'-0" 3'-3" 16 4'-1" 4'-4" 4'-4" 0.695 1.176 0.362 0.078 1 0.113 30" 3'-4" 3'-4" 3'-9" 16 4'-5" 4'-8" 4'-8" 0.807 1.481 0.395 0.122 0.170 36" 4'-0" 4'-0" 4'-3" 20 5'-1" 5'-4" 5'-4" 1.053 1.959 0.461 0.176 0.238 42" 4'-8" 4'-8" 4'-9" 22 5'-9" 6'-0" 6'-0" 1.333 2.503 0.527 0.240 0.323 48" 5'-4" 5'-4" 5'-3" 26 6'-5" 6'-8" 6'-8" 1.646 2.940 0.560 0.313 0.422 54 5'-10" 5'-10" 5'-9" 28 6'-11" 7'-2" 7'-2" 1.902 3.502 0.609 0.396 0.535 60" 6'-6" 6'-6" 6'-3" 30 7'-7" 7'-10" 7'-10" 2.272 4.113 0 .658 0.489 0.660 66" 7'-1" 7'-1" 6'-9" 32 8'-2" 8'-5" 8'-5" 2.624 1 4.778 1 0.708 1 0.591 0.798 z z O 0 � Q H O I) �e _ } U = N 12 O CO Q O _ HEET 1 OF 1 840.32 site solutions civil engineering I Land surveying 409 Chicago Drive, Suite.U2, Fayetteville, NC 28306 office 910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesotutions.com QA SEA 02 COT •• G) NE ••: ja��� U3-30-22 REVISIONS PROJECT NAME WOODSHIRE SUBDIVISION PHASE 8 STORM DETAILS CLIENT WOODSHIRE HUFF, LLC 2919 Breezewood Avenue - Suite 100 Fayetteville, North Carolina 28303 Phone: (910) 486-4864 PROJECT INFORMATION DESIGNED BY: BRETT DRAWN BY: BRETT CHECKED BY: SCOTT PROJECT NUMBER: 1775 DRAWING SCALE NOT TO SCALE DATE RELEASED MARCH 30, 2022 SHEET NUMBER -6■ 6