HomeMy WebLinkAboutSW6220201_Plansheet C4.0 - Grading_Drainage Plan_20220510VICINITY MAP
NOT TO SCALE
LEGEND:
ECM® ECM —EXISTING CONCRETE MONUMENT
ERBO ERB—EXISTING REBAR
o COMPUTED POINT
N/F — NOW OR FORMERLY
R/W — RIGHT OF WAY
RCP — REINFORCED CONCRETE PIPE
PROPERTY LINE
ADJACENT PROPERTY LINE
RIGHT—OF—WAY
—SETBACK LINE
ss SANITARY SEWER LINE
FM FORCE MAIN LINE
so STORM DRAINAGE
W WATER LINE
OVERHEAD UTILITY
PERMANENT EASEMENT
TREE LINE
210 MAJOR CONTOUR
207 MINOR CONTOUR
x 208.47' SPOT ELEVATION
BENCHMARK
PP UTILITY POLE
C• GUY WIRE
❑T TELEPHONE PEDESTAL
wv
D4 WATER VALVE
FIRE HYDRANT
�S SANITARY SEWER MANHOLE
ASPHALT
0 CONCRETE
WETLANDS
PROPOSED SANITARY SEWER MANHOLE
• PROPOSED CLEANOUT
A� L�J PROPOSED FIRE HYDRANT
PROPOSED WATER METER
H PROPOSED WATER VALVE
• PROPOSED BLOW OFF
F7A PROPOSED TEE
SEE SHEET C 5.8 — C 5.10 FOR OFF SITE WATER EXTENSION
R/W (PUBLIC
_ --- 05-
�_Jij�
i�
i,ll '• 11�11A � \\ l
I N/F \
I WOODSHIRE PARTNERS, LLC
I I I DB 3446, PG 969
I I I I I \ l
1 \ \ \ \ \ \ \\ \\ \ \ \\ \ \\ v\\ \ \\\\
=
-_-_-_��_/ j j/•/ //�/ /j/ ///r�I. II .ill 1 �� �
---,- _�/////////////j///j/� I III'; �\ �` ', \ \♦
W • \ i� J/�/ / ///�//`11 I N 567,403.47
E 2, 008, 481.37
♦ �j i, jj j j 1/� ♦ j / NC GRID NAD 83
� � � _ ►�v 5/8"
__ _ . �� ERB (�
ER 420
.�' �422
_ • i_ T I J _
�418;
tt
/,,`
1. APPROVAL OF THIS PLAT/PLAN DOES NOT GUARANTEE WATER CAPACITY.
CURRENT/FUTURE CAPACITY MAY NOT BE AVAILABLE. THIS DEVELOPMENT
MAY REQUIRE ADDITIONAL IMPROVEMENTS TO THE EXISTING WATER SYSTEM
TO MEET FUTURE WATER DEMANDS PRIOR TO A PRELIMINARY PLAT,
CONSTRUCTION PLAN AND/OR FINAL PLAT APPROVAL.
2. PAVEMENT, SIDEWALKS, AND STREET TREES ARE TO BE MAINTAINED BY
THE HOME OWNERS ASSOCIATION ("HOA"). PAVEMENT, SIDEWALK, OR STREET
TREE INSTALLATIONS THAT ARE DAMAGED AND/OR REMOVED BY HARNETT
COUNTY/DEPARTMENT OF PUBLIC UTILITIES/HARNETT REGIONAL WATER OR ITS
REPRESENTATIVES, AGENTS, OR CONTRACTORS AS A RESULT OF REPAIR/
MAINTENANCE OF THE PUBLIC WATER AND/OR SEWER LINE WILL BE REPLACED
OR REPAIRED BY THE HOA.
3. EACH DROP MH SHALL INCLUDE AN INTERIOR LINING IN ACCORDANCE
WITH HRW STANDARD SPECIFICATIONS SECTION 5.6.2
I
■—■■_■.-0■00006
- � 1
N/F
WOODSHIRE PARTNERS, LLC.
DB 2668, PG 901
I
■
NV
,ht94r - �r — '3.29 -- -- -- -- ----
� W8— OW
TBM
4D ECS #181
N 568,836.892
E 2,008,250.099
ELEV 339.17
INC GRID NAD 83
(2011)
NAVD 88
o
� $31201�1
GAO NP
N
N/F
HARNETT FORWARD TOGETHER COMMITTEE
DB 2193, PG 653
Know what's below.
Call before you dig.
♦ ■ tK[3
N/F
\� WOODSHIRE PROPERTIES, INC. GRAPHIC SCALE
\\ DB 1899, PG 868
/ ♦♦ `, � �� I , 100 0 50 100 200
II ♦� ( IN FEET )
\\ 1 inch = 100 ft.
THE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 72 HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATED
4Dsite
solutions
civil engineering I land surveying
409 Chicago Drive, Suite.U2, Fayetteville, NC 28306
office 1910-426-6777 fax 1910-426-5777 license number I C-2354
www.4Dsitesotutions.com
IICARO,��'''
S$16... i
SEA
02
.. G I NE ••: ja���
REVISIONS
PROJECT NAME
WOODSHIRE
SUBDIVISION
PHASE 8
OVERALL
UTILITY PLAN
PIN:
0506-88-4099.000
CLIENT
WOODSHIRE HUFF,
LLC
2919 Breezewood Avenue - Suite 100
Fayetteville, North Carolina 28303
Phone: (910) 486-4864
PROJECT INFORMATION
DESIGNED BY:
BRETT
DRAWN BY:
BRETT
CHECKED BY:
SCOTT
PROJECT NUMBER:
1775
DRAWING SCALE
HORIZONTAL: 1 "=100'
DATE RELEASED
MARCH 30, 2022
SHEET NUMBER
C-400