Loading...
HomeMy WebLinkAboutWS0801069_Application_20220803 (3)ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director NORTH CAROLINA Envir wurtental Quality Preliminary Well Site Approval Letter October 14, 2021 Columbus County District II Attn: Harold Nobles, Public Utilities Director 612 N. Madison St. Whiteville, NC 28472 Re: Dear Mr. Nobles: Preliminary Well Site Approval Columbus County District 11 NC7024007 On September 22, 2021,1 met with Mr. Steve Mitchell, Green Engineering, to conduct a preliminary investigation of the proposed well site listed below. The previous well site for W03 was approved on April 3, 2020. The test well at that location did not meet water quality standards suitable as a source. The revised proposed well has been assigned a Water System Facility (WSF) Identification Number and Sampling Point Code as indicated below. Attached is a copy of the map provided by Mr. Leo Green, Green Engineering, which depicts the location of the proposed well. The abandoned pump station shown of the map will be removed from the proposed well site. WSF ID Sampling Description of Well Site Preliminary Latitude and No. Point Code Longitude W03 RW3 —170' SE of James B. White 34.177246,-78.812432 Hwy S This letter is provided by Public Water Supply (PWS) Section, in accordance with rule .0305(b) of the Rules Governing Public Water Systems (15A NCAC 18 C), to provide permission to drill a well at the listed site in order to establish water quality and quantity and suitability of the well as a source for a public water system. In addition, this "preliminary well site approval" is to acknowledge that according to the information and documentation provided, we understand that the proposed well is located on a lot so that the area within 100 feet of the wells is owned or controlled by the person supplying the water and that the supplier of water will protect the well lot from potential sources of pollution and construct landscape features for drainage and diversion of North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington, North Carolina 28405 noarncaroum u•o.M•wareea.aMa aam� /`� 910.796.7215 pollution as required in rule .0203(1). In addition, we understand that you have determined that the proposed well locations satisfy the minimum horizontal separation distances specified in rule .0203 (2) and summarized in the following table: Distance (in Potential Source of Pollution feet 100 • From any sanitary sewage disposal system, sewer, or sewer pipe (unless sewer is constructed of water main materials and joints, in which the sewer pipe shall be at least 50 feet from the well. • From buildings, mobile homes, permanent structures, animal houses or lots, cultivated areas to which chemicals are applied. • From surface water. • From a chemical or petroleum fuel underground storage tank with secondary containment. • From any other potential source of pollution not listed in this table. 200 • From a subsurface sanitary sewage treatment and disposal system designed for 3,000 or more gallons of wastewater a day, unless your well water source is a confined aquifer. 300 From any cemetery or burial ground. 500 • From a septage disposal site. • From a chemical or petroleum fuel underground storage tank without secondary containment • From the boundary of a ground water contamination area. • From a sanitary landfill or non -permitted non -hazardous solid waste disposal site. 1,000 • From a hazardous waste disposal site or in any location which conflicts with the North Carolina Hazardous Waste Management Rules cited in NCAC 13A. We also understand that the owner will ensure that the lot is graded or sloped so that surface water is diverted away from the wellhead and that the lot is not subject to flooding in accordance with rule .0203(4). PWS Section "Authorization to Construct" and "Final Approval" Subsequent to well drilling and evaluating water quality and quantity (e.g., collecting and analyzing samples and performing a 24-hour well drawdown test) the owner must submit an "Application for Approval of Engineering Plans and Specifications for Water Supply Systems" to document proposed well completion (e.g., selected pump, wellhead and well house details) and associated transmission lines, treatment and/or storage facilities and other critical information about the public water system. In accordance with rule .0305(a) no construction shall be undertaken until the PWS Section issues an "Authorization to Construct' letter. In addition, in accordance with .0309(a) the new well and all associated treatment, storage or transmission/distributions lines shall not be placed into service until the PWS Section has issued a "Final Approval." These steps are described in the Engineering Planning and Development Guidance Document available at https•//files nc gov/ncdeq/Water%20Resources/files/pws/planreview/EPD Guidance Jul ,v2019.pdf North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1127 Cardinal Drive Extension I Wilmington, North Carolina 28405 nvmrca+ouru ow,e..ma uiw�miaowr 910.796.7215 Be aware that plans, specifications and reports for the new wells must be certified by a Professional Engineer. Therefore, it is recommended that a Professional Engineer or Licensed Geologist (or their designated representative) experienced in the construction of water supply wells, conduct on -site monitoring of well construction. At a minimum, certain critical phases of well construction such as installation and grouting of casing should be monitored. In many situations it may be necessary to go beyond the minimum requirements in order to protect the public health and ground water resources. Other Agency Approvals Required This PWS Section "preliminary well site approval" letter does not address other agency applicable rules and requirements pertaining to well construction and registration. Local county well construction rules and ordinances may include additional requirements. Well construction must meet the standards specified in the Well Construction Standards (15A NCAC 2C). Be aware that these rules require a permit to be obtained from the Water Quality Regional Operations Section of the Division of Water Resources before the well is constructed if it is anticipated that the new well will be part of a water system with a design capacity of 100,000 gallons per day or greater. In addition, these rules require that wells be constructed by a properly certified well driller. For more information contact the Water Quality Regional Operations Section at 919-807-6300 or http://portal.ncdenr.org/web/M/gps Sincerely, Jeannine Press Engineer Wilmington Regional Office Cc: Central Files, Public Water Supply Section Heidi Lane Cox, Regional Engineering Supervisor, Public Water Supply Section Columbus County Health Department Morelia Sanchez -King, Regional Supervisor, Water Quality Regional Operations Section E. Leo Green, P.E., 303 Goldsboro Street, East, P.O. Box 609, Wilson, NC 27893 D E O%Z North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington, North Carolina 28405 rvomv cumuru �/ o.we.mam.uu�.ai_ _ / 910.796.7215 NO GRID COORDINATE / NADe3 (2011) / N=155,711.271' E=2,056,713.03' (CONTROL CORNER) / ry6, n� P�ry,1/`�MN�y Cr/ SIR i M LEGEND HIP oEXISTING IRON PIPE EIR OEXISTING IRON REBAR NIR • NEW IRON REPAIR UP EDGE OF PAVEMENT PROPERTY LINE (SURVEYED) PROPERTY LINE (SURVEYED) ----- EDGE OF PAVEMENT RIGHT—OF—WAY LINE SCALE IN FEET SURVEY NOTES: THIS GJNI WAS GOMPIEIE➢ WITHOUT THE BENEFIT OF A TITLE SEARCH AND DOES NOT CONSTITUTE A T7UE SEARCH BY BRIER ENGINEERING, PLUG. THIS PROPERTY IS SUBJECT TO ALL EASEMENTS. AGREEMENTS. AND RIGHTS -OF -WAY OF RECpN, NO HORIZONTAL CONTROL MONUMENT WAS FOUND WITHIN 2". T115 SURVEY WAS ISRFORMED U.N. NO MRS RN WITH A TRIM6L£ RB RECEIVER AND TED TO NC STATE PLANE GRID NORTH. HORIZONTAL CONTROL IS BASED ON NO STATE PLANE GRID NORTH. NADAT (2011) AS DETERMINE) BY GPS THIS PROPERTY UPS IN ZONE X. NOT A SPECIAL ROOD HAZARD AREA AS PER REM COMMUNITY PANEL NO. 372001H00(. DAM DECEMBER G, MS. AREA COMPUTATION IS BY THE COORDINATE METHOD. RIGHT-OF-WAY AND PROPERTY BOUNDARY INFORMATION IS BASED ON RETNENGES AS GROW HEREON. N /WANOA MCDUEFIE PROPERTY / OVIEDO DB. 325 PG. 470 / EIP S ABANDONED PUMP STATION NEW TRACT 1.03 ACRES 3 O M34 10,GEET NIL. O N34' ID' 3 ,67 n / WIB' 46' 4467' Q GREEN ENGINEERING NC FIRM LICENSE: P0115 WATER, WASTEWATER ,SURVEYING, PLANNING, PROJECT MANAGEMENT G03 G0 DSBOR0 ST E, P.O. BOX OA9 WLSGN, N C. P693 TEL(252)237-53M5 FAX(252) 2417489 ofivoGOM 9COM Y4 N WLUMBUS COUNTY BOARD EDUCATION PROPERTY N 017315 ED. 408 PG. 121 BE. 50 PG BE I / EP N HOWARD k CHERIL CRIBB PROPERTY III DO. 600 PG 710 7'40"E 6' (TOTALi N I, E. FLED GREEN III, CERTIFY THAT THIS MAP WAS DRANK UNDER MT SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVSION (DEED REFERENCES AS SHOW HEREON); THAT THE BOUNDARIES NOT SURVEYED ARE CLEARLY INDICATED AS DRAWN FROM INFORMATION FOUND IN REFERENCES AS SHOW HEREON; THAT THE RATIO Cf PREOSON OR POETONAL ACCURACY AS CALCULATED IS 100,000+: THAT THIS MAP MEETS THE REQUIREMENTS OF THE STANDARDS OF PRACTICE FOR LAND SURVE NG IN NORTH CAROLINA (21 NCAC 56, 1600). `MTTTTTlJJJJ��GGGGGGSS MT .INAL SIpIhTJRE. LICENSE NUMBER, AND SEAL 1H13 3 AY OF AU UST (U 202ER E LEO GREEN PR BAL LAND ISURVEYOR L-2225 THIS MAP MAY NOT BE A SERTF:EO SURVEY AND HAS NOT BEEN RENEWED BY A LOCAL GOVERNMENT AGENCY FOR COMPLIANCE WVFH MY APPLICABLE LAND DEVELOPMENT REGUTATIONS AND HAS NOT BEEN REVIEWED FOR COMPLIANCE WITH RECORDING REQUREMENTS FOR PLATS.' BOUNDARY EXHIBIT COLUMBUS COUNTY WATER DISTRICT TWO - WELL SITE JAMES B WHITE HWY S - US 701 WILLIAMS TOWNSHIP