Loading...
HomeMy WebLinkAboutWQ0011313_Compliance Evaluation Inspection_20220727DocuSign Envelope ID: 6BF04107-369C-4700-B934-31040A3B286E Compliance Inspection Report Permit: WQ0011313 SOC: County: Carteret Region: Wilmington Effective: 11/15/18 Expiration: 09/30/23 Effective: Expiration: Owner : Festiva Real Estate Holdings LLC Facility: Peppertree Resort WWTP 715 W Fort Macon Rd Atlantic Beach NC 28512 Contact Person: Donna Baker Title: Phone: Directions to Facility: From Wilmington, follow US 17N to NC 24 E to US 70E. Turn right on Atlantic Beach Causeway, Turn right on NC 58W, facility is on the left. System Classifications: WW2, Primary ORC: Robert C Howard Certification: 996013 Phone: 252-241-5460 Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 07/27/2022 Primary Inspector: Helen I Perez Secondary Inspector(s): Reason for Inspection: Routine Entry Time 10:OOAM Exit Time: 11:10AM , I IDocuSignedd by: 6bA, 1 e/V2 2:5,—DocuSi�gnne�d by: 1 D645B4A39694BE... l0Ati lY�afn Oti "-7F141E73B6F3456... Inspection Type: Compliance Evaluation Permit Inspection Type: High Rate Infiltration Facility Status: ❑ Compliant Question Areas: Not Compliant ▪ Treatment Flow Measurement -Effluent ▪ Treatment Flow Measurement -Water Use Records ▪ Treatment Filters ▪ Treatment Sludge Storage/Treatment ▪ Treatment Disinfection ▪ Treatment Return pumps (See attachment summary) ▪ Treatment Flow Measurement -Influent ▪ Treatment ▪ Record Keeping ▪ Treatment Influent Pump Station ▪ End Use -Infiltration ▪ Standby Power Phone: 910-796-7387 ▪ Miscellaneous Questions ▪ Treatment Barscreen ▪ Treatment Activated Sludge ▪ Treatment Clarifiers ▪ Treatment Flow Measurement Page 1 of 7 DocuSign Envelope ID: 6BF04107-369C-4700-B934-31040A3B286E Permit: WQ0011313 Owner - Facility: Festiva Real Estate Holdings LLC Inspection Date: 07/27/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: A routine compliance inspection of the Peppertree WWTF was conducted on July 27, 2022. The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit WC0011313. Dan Fortin and RC Howard were present during the inspection. This facility is a 80,000 gpd extended aeration plant with two drip irrigation, high -rate infiltration fields. Flow peaked to approximately 40,000 gpd this summer season. All visual/audio alarms throughout both plants were tested and found to be operable, but there is no telemetry for these alarms. This situation can be challenging for staff when issues arise during off hours. Since the last inspection in January 2020, the non -active tanks (original trains) have been removed, and the existing two plants were sandblasted, structurally repaired and recoated except for the dosing tank. The high -rate infiltration fields are now maintained by the condo association staff and appear to be in good condition. The following items were found to be non -compliant during this inspection and needs to be addressed: 1. The dosing tank is severely corroded and is in need of sandblasting, repair and recoating or replacement. 2. The two blowers for the northside plant are inoperable and need to be repaired or replaced. 3. The UV system is inoperable on the southside plant. This system needs to be replaced or a proper disinfection contact chamber needs to be installed. 4. Soil analysis of the infiltration fields needs to be conducted annually. 5. A full description of the facility, addressing the discrepancies between the facility description in the current permit and the actual plant, needs to be submitted (Permit Schedule 1.1). 6. Submittal of the Operator Designation Form to update the current ORC/BORC. Please review the comment sections of the inspection report for more details. The facility is noncompliant with Non -Discharge Permit WQ0011313 and an Notice of Violation will be issued. A plan of action to address the six items listed above is requested within 30 days of receipt of this report. Page 2 of 7 DocuSign Envelope ID: 6BF04107-369C-4700-B934-31040A3B286E Permit: WQ0011313 Owner - Facility: Festiva Real Estate Holdings LLC Inspection Date: 07/27/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Reuse (Quality) Lagoon Spray, LR Single Family Spray, LR Activated Sludge Spray, LR Activated Sludge Drip, LR Activated Sludge Spray, HR Recycle/Reuse Single Family Drip Infiltration System Treatment Are Treatment facilities consistent with those outlined in the current permit? Do all treatment units appear to be operational? (if no, note below.) Yes No NA NE Yes No NA NE ❑ • ❑ ❑ Comment: The description in the current permit needs to be updated to address the discrepancies between the facility description and the actual facility. The blowers for the northside plant are not operable, as well as the UV system for the southside plant. The anoxic basin are not in use but being used as additional flow EQ. Treatment Influent Pump Station Is the pump station free of bypass lines or structures? Is the general housekeeping acceptable? Are all pumps present? Are all pumps operable? Are floats/controls operable? Are audio and visual alarms available? Are audio and visual alarms operational? # Are SCADA/Telemetry alarms required? Are SCADA/Telemetry available? Are SCADA/Telemetry operational? Comment: Staff indicated that they found an issue to repair during the inspection. Treatment Flow Measurement -Influent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Yes No NA NE • ❑ ❑ ❑ N EED • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ with the high-level float that morning and were working Yes No NA NE ❑ ❑ •❑ ❑ ❑ • ❑ Page 3 of 7 DocuSign Envelope ID: 6BF04107-369C-4700-B934-31040A3B286E Permit: WQ0011313 Owner - Facility: Festiva Real Estate Holdings LLC Inspection Date: 07/27/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Comment: Treatment Flow Measurement -Water Use Records Is water use metered? Are the daily average values properly calculated? Comment: Treatment Flow Measurement -Effluent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Comment: The flowmeter was calibrated on 04/05/2022 by Delta Environmental. Standby Power Is automatically activated standby power available? Is generator tested weekly by interrupting primary power source? Is generator operable? Does generator have adequate fuel? Yes No NA NE ❑ ❑ • ❑ ❑ ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑• • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • Comment: The generator is rented and maintained by PowerHouse. The generator was automatically activated and power transferred to the plant when power was interrupted during the inspection. However, after approximately 10 minutes, the generator shut down. Saff indicated that PowerHouse will be called to repair as soon as possible. Treatment Barscreen Is it free of excessive debris? Is disposal of screenings in compliance? Are the bars spaced properly? Is the unit in good condition? Comment: No comment. Treatment Activated Sludge Is the aeration mechanism operable? Is the aeration basin thoroughly mixed? Is the aeration equipment easily accessed? Is Dissolved Oxygen adequate? Are Settleometer results acceptable? Is activated sludge an acceptable color? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑• • ❑ ❑ ❑ Yes No NA NE ▪ • • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ Comment: The 2 blowers from the northside plant were not operable. The 2 blowers from the southside plant provide aeration to both plants. Page4of7 DocuSign Envelope ID: 6BF04107-369C-4700-B934-31040A3B286E Permit: WQ0011313 Owner - Facility: Festiva Real Estate Holdings LLC Inspection Date: 07/27/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Treatment Clarifiers Are the weirs level? Are the weirs free of solids and algae? Is the scum removal system operational? Is the scum removal system accessible? Is the sludge blanket at an acceptable level? Is the effluent from the clarifier free of excessive solids? Comment: No comment. Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • • ❑ ❑ ❑ Treatment Return pumps Yes No NA NE Are they in place? • ❑ ❑ ❑ Are they operational? • ❑ ❑ ❑ Comment: No comment. Treatment Filters Yes No NA NE Is the filter media present? • ❑ ❑ ❑ Is the filter media the correct size and type? ❑ ❑ ❑ • Is the air scour operational? • ❑ ❑ ❑ Is the scouring acceptable? • ❑ ❑ ❑ Is the clear well free of excessive solids? • ❑ ❑ ❑ Is the mud well free of excessive solids and filter media? • ❑ ❑ ❑ Does backwashing frequency appear adequate? • ❑ ❑ ❑ Comment: Tertiary filters are manually backwashed daily. Treatment Sludge Storage/Treatment Is the aeration operational? Is the aeration pattern even? If required, are Sanitary "Ts" present in tankage? Comment: Sludge is hauled from the facility by Barnes Environmental. Yes No NA NE • ❑ ❑ ❑ ❑ ❑ ❑• ❑ ❑ • ❑ Treatment Disinfection Yes No NA NE Is the system working? ❑ • ❑ ❑ Do the fecal coliform results indicate proper disinfection? • ❑ ❑ ❑ Is there adequate detention time (>=30 minutes)? ❑ ❑ ❑ • Is the system properly maintained? ❑ • ❑ ❑ If gas, does the cylinder storage appear safe? ❑ ❑ • ❑ Is the fan in the chlorine feed room and storage area operable? ❑ ❑ • ❑ Is the chlorinator accessible? • ❑ ❑ ❑ If tablets, are tablets present? • ❑ ❑ ❑ Page5of7 DocuSign Envelope ID: 6BF04107-369C-4700-B934-31040A3B286E Permit: WQ0011313 Owner - Facility: Festiva Real Estate Holdings LLC Inspection Date: 07/27/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Are the tablets the proper size and type? ❑ ❑ ❑ • Is contact chamber free of sludge, solids, and growth? • ❑ ❑ ❑ If UV, are extra UV bulbs available? ❑ ❑ • ❑ If UV, is the UV intensity adequate? ❑ ❑ • ❑ # Is it a dual feed system? ❑ ❑ • ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ • ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ • ❑ If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: The UV system for the southside plant has been inoperable for many years according to staff. Effluent from that plant is chlorine disinfected before reaching the dosing tank. A proper disinfection contact chamber or new UV system needs to be installed. Record Keeping Is a copy of current permit available? Are monitoring reports present: NDMR? NDAR? Are flow rates less than of permitted flow? Are flow rates less than of permitted flow? Are application rates adhered to? Is GW monitoring being conducted, if required (GW-59s submitted)? Are all samples analyzed for all required parameters? Are there any 2L GW quality violations? Is GW-59A certification form completed for facility? Is effluent sampled for same parameters as GW? Do effluent concentrations exceed GW standards? Are annual soil reports available? # Are PAN records required? # Did last soil report indicate a need for lime? If so, has it been applied? Are operational logs present? Are lab sheets available for review? Do lab sheets support data reported on NDMR? Do lab sheets support data reported on GW-59s? Are Operational and Maintenance records present? Were Operational and Maintenance records complete? Has permittee been free of public complaints in last 12 months? Is a copy of the SOC readily available? Yes No NA NE • ❑ ❑ ❑ ❑ ❑ ❑• ❑ ❑ ❑• • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑• • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑•❑ • ❑ ❑ ❑ ❑ ❑ ❑• ❑ ❑ ❑• ❑ ❑ ❑• • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑•❑ Page6of7 DocuSign Envelope ID: 6BF04107-369C-4700-B934-31040A3B286E Permit: WQ0011313 Owner - Facility: Festiva Real Estate Holdings LLC Inspection Date: 07/27/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine No treatment units bypassed since last inspection? ❑ ❑ • ❑ Comment: Operation and maintenance log and daily sheets were available for review. Groundwater monitoring since 2019 indicates erratic ammonia, nitrate and chloride exceedances. Effluent monitoring shows 4 violations for TSS limit exceedances, 2 violations for fecal coliform and 1 BOD violation. Annual soil analysis has not been conducted on the each infiltration sites as required. End Use -Infiltration # Is the application High Rate or Low Rate? Are buffers maintained? Are any supply wells within the CB? Are any supply wells within 250' of the CB? Is municipal water available in the area? Are GW monitoring wells required? Are GW monitoring wells located properly w/ respect to RB and CB? Are GW monitoring wells properly constructed, including screened interval? Is a usable green area maintained? Is the disposal site acceptable? Is the distribution equipment acceptable? Is the disposal site free of ponding? Is the disposal site free of breakout? Are the disposal sites free of solids, algae, etc.? Do the records show that the fields are properly maintained? Are the disposal sites free of vegetation? Do any surface water features appear to be adversely impacted by GW discharge? No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.? Yes No NA NE High Rate Comment: The most current map indicates that several wells are improperly located outside of the compliance boundry. The drip fields are maintained by the condo association staff. • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 7 of 7