HomeMy WebLinkAboutWQCSD0195_Compliance Evaluation Inspection_20220701Compliance Inspection Report Permit: WQCSD0195 Effective: 03/01/00 Expiration: SOC: Effective: Expiration: County: Davidson Region: Winston-Salem Contact Person: Randy Simmons Directions to Facility: Owner : Aqua North Carolina Inc Facility: Spring Creek Subdivision Collection System Title: Phone: 336-992-9000 System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 07/01/2022 Entry Time 09:OOAM Exit Time: 12:OOPM Primary Inspector: Patricia Lowery Phone: 336-776-9691 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Deemed permitted collection system management and operation Facility Status: Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions General Grease Control II Spills/Response Plan Inspections Lines (See attachment summary) Page 1 of 4 Permit: WQCSD0195 Owner - Facility:Aqua North Carolina Inc Inspection Date: 07/01/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: On July 1, 2022, Tricia Lowery with the Division of Water Resources conducted a Compliance Evaluation Inspection of Spring Creek Collection System (WQCSD0195). Ryan Smith of Aqua Systems was present for inspection. The inspection consisted of two parts: 1) file review and 2) field inspection of collection system. The collection system is a small private community system. This collection system has no high priority lines, and no pump stations. Overall, the collection system is properly operated and maintained. Page 2 of 4 Permit: WQCSD0195 Owner - Facility:Aqua North Carolina Inc Inspection Date: 07/01/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine General # Is this system a satellite system? # If Yes, what is system name or permit number? Is there a overall sewer system map? Does the map include: Pipe sizes Pipe materials (PVC, DIP, etc) Pipe location # Flow direction # Approximate pipe age # Pump station ID, location and capacity # Force main air release valve location & type # Location of satellite connections Are system maintenance records maintained? Comment: Aqua systems utilizes GIS system for map. It is updated as needed. Satisfactory. Grease Control Is grease/sewer education program documented with req'd customer distribution? # Are other types of education tools used like websites, booths, special meetings, etc? If Yes, what are they? (This can reduce mailing to annual.) For public systems, is there a Grease Control Program via an ordinance/agreement? ❑ ❑ • ❑ If Yes, does it require grease control devices at applicable locations? ❑ ❑ • ❑ Is the Grease Control Program enforced via periodic inspections/records review? ❑ ❑ • ❑ Is action taken against violators? ❑ LIM El Comment: This is a small private community collection system. FOG program consists of mailing flyers to residence bi-annually. Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • Spills and Response Action Plan # Is system free of known points of bypass? If No, describe type of bypass and location # Have there been any sewer spills in the past 3 years? If Yes, were they reported to the Division if meeting the reportable criteria? If applicable, is there documentation of press releases and public notices issued? Are all spills or sewer related issues/complaints documented? # Are there repeated overflows/problems (2 or more in 12 months) at same location? # If Yes, is there a corrective action plan? Is a Spill Response Action Plan available? Yes No NA NE • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ Page 3 of 4 Permit: WQCSD0195 Owner - Facility:Aqua North Carolina Inc Inspection Date: 07/01/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Is a Spill Response Action Plan available for all personnel? Does the plan include: # 24-hour contact numbers # Response time # Equipment list and spare parts inventory # Access to cleaning equipment # Access to construction crews, contractors, and/or engineers # Source of emergency funds # Site sanitation and cleanup materials # Post-overflow/spill assessment • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: Spill response is satisfactory. No spills reported over the last 3 years. TriState is contracted to camera lines annually. Subsurface is contracted to conduct line flushing of system annually. All maintenance is documented. Additionally, Aqua Systems contracts a company for root control during the same time as when TriState cameras lines. Inspections Are adequate maintenance records maintained? Are pump stations being inspected at the required frequency? Is at least one complete functionality test conducted weekly per pump station? Is there a system or plan in place to observe the entire system annually? Is the annual inspection documented? # Does the system have any high -priority lines/locations? Are inspections of HPL documented at least every 6 months? Are new lines being added to the HPL list when found or created? Comment: There are no pump stations or HPLs in this system. Lines/Right-of-Ways/Aerial Lines Please list the Lines/Right of Ways/Aerial Lines Inspected: No aerial lines in this system. Right of ways are maintained by community landscaping. Are right-of-ways and easements maintained for the full width for access? If No, give details on temporary access: Is maintenance documented? Were all areas/lines inspected free of issues? Comment: Again, no HPLs in this collection system. Yes No NA NE • ❑ ❑ ❑ ▪ • ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ❑ ❑ • ❑ ❑ ❑ • ❑ Page 4 of 4