Loading...
HomeMy WebLinkAboutNCG030329_2022 DMR_20220526NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR1 Unload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0329 Person Collecting Samples: John L. Sherrill, S&ME Facility Name: Honda Power Equipment Manufacturing Laboratory Name: Pace Analytical Services, Inc. Facility County: Alamance Laboratory Cert. No.: NCDENR 329 Discharge during this period:UYes IJ No (if no, skip to tore and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? If so, which Tier (I, II, or III)? Tier I A copy of this DMR has been uploaded electronically via htt2s:/Iedocs.deci.nc.gov/Farms/SW-DMR Date Uploaded: Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Yes 1 I No D Yes El No Parameter Parameter — Outfall HPE-01 Outfall HPE-02 Outfall HPE-03 Outfall HPE-04 Outfall Code Receiving Stream Class N/A WS-V-NSW WS-V-NSW WS-V-NSW WS-V-NSW N/A Date Sample Collected MM/DD/YYYY 01/09/2022 01/09/2022 01/09/2022 01/09/2022 46529 24-Hour Rainfall in inches 0.55 0.55 0.55 0.55 C0530 TSS in mg/L (100 or 5o*) 5.6 35 13 160 00400 pH in standard units (6.0-9.0 FW, 6.4 6.5 6.5 6.8 6.8-8.5 SW 01119 Copper, total recoverable in mg/L BDL BDL BDL 0.011 0.010 FW, 0.0058 SW) 01051 Lead, total recoverable in mg/ L BDL BDL BDL 0.027 (0.075 FW, 0.22 SW) 01094 Zinc, total recoverable in mg/ L (0.126 _ 0.029 0.016 0.016 0.018 FW, 0.095 SW) Chemical Oxygen Demand (COD) in BDL BDL 00340 BDL 38 mg/L(1201 BDL BDL 00552 Non -Polar Oil & Grease in mg/L (15) BDL BDL * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (o tlona l): Tier I respanse initialed VOM022 Details regarding the reason for response MOB of time perlod required by Cre general pannitsubmited to Winston-Salem Regional Olrm vie fetter dated April 28, 2022. "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 5-z5 —zz- Signature of Permittee or Delegated Authorized Individual Date david—werden@na.honda.com Email Address Phone Number