HomeMy WebLinkAboutNCG030329_2022 DMR_20220526NCDEQ Division of Energy, Mineral and Land Resources
Stormwater Discharge Monitoring Report (DMR) Form for NCG030000
Metal Fabrication
Click here for instructions
Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR1 Unload form within
30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office.
Certificate of Coverage No. NCG03 0329 Person Collecting Samples: John L. Sherrill, S&ME
Facility Name: Honda Power Equipment Manufacturing Laboratory Name: Pace Analytical Services, Inc.
Facility County: Alamance Laboratory Cert. No.: NCDENR 329
Discharge during this period:UYes IJ No (if no, skip to
tore and date)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances?
If so, which Tier (I, II, or III)? Tier I
A copy of this DMR has been uploaded electronically via htt2s:/Iedocs.deci.nc.gov/Farms/SW-DMR
Date Uploaded:
Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red)
Yes 1 I No
D Yes El No
Parameter
Parameter —
Outfall HPE-01
Outfall HPE-02
Outfall HPE-03
Outfall HPE-04
Outfall
Code
Receiving Stream Class
N/A
WS-V-NSW
WS-V-NSW
WS-V-NSW
WS-V-NSW
N/A
Date Sample Collected MM/DD/YYYY
01/09/2022
01/09/2022
01/09/2022
01/09/2022
46529
24-Hour Rainfall in inches
0.55
0.55
0.55
0.55
C0530
TSS in mg/L (100 or 5o*)
5.6
35
13
160
00400
pH in standard units (6.0-9.0 FW,
6.4
6.5
6.5
6.8
6.8-8.5 SW
01119
Copper, total recoverable in mg/L
BDL
BDL
BDL
0.011
0.010 FW, 0.0058 SW)
01051
Lead, total recoverable in mg/ L
BDL
BDL
BDL
0.027
(0.075 FW, 0.22 SW)
01094
Zinc, total recoverable in mg/ L (0.126
_
0.029 0.016
0.016
0.018
FW, 0.095 SW)
Chemical Oxygen Demand (COD) in
BDL BDL
00340
BDL
38
mg/L(1201
BDL BDL
00552
Non -Polar Oil & Grease in mg/L (15)
BDL
BDL
* Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L
FW (Freshwater) SW (Saltwater)
Notes (o tlona l): Tier I respanse initialed VOM022 Details regarding the reason for response MOB of time perlod required by Cre general pannitsubmited to Winston-Salem Regional Olrm vie fetter dated April 28, 2022.
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information
submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting
false information, including the possibility of fines and imprisonment for knowing violations."
5-z5 —zz-
Signature of Permittee or Delegated Authorized Individual Date
david—werden@na.honda.com
Email Address
Phone Number