Loading...
HomeMy WebLinkAboutNCG140511_Site Plan Pg5_20220801I I ' I I I I I � , I , „ I I ASPHALT EXISTING ASPHALT WHICH IS - TO REMAIN , , , CONCRETE SWALE/If'LET i I i i I AGGREGATE AGGREGATE AGGREGATE STOCKPILES STOCKPILES STOCKPILES I I I I AGGREGATE STOCKPILES '� III I II I'I i 0.67t AC I i i I I r I I I O v I i N I , N , I --x1sygN CONCRETE I ! I BATCH PLANT , N d � , r I ASPHALT N OUTFALL001 N320 58' 40.3" W780 55' 32.6" rti I I , n �z - I I i I , 11 I EXISTING I I � � ASPHALT � _ C N N N N N N - WHICH IS TO i �I I i N �- REMAIN I I ; I ; I , I �� 6.4 AC , I y 1 - , o III I I , I , I II II I I I ' EXISTING ASPHALT WHICH IS s--RVIc:E _ � I I - TO REMAIN I SF ' I I , t _ I c�NN CONCRETETWASHOU YARD PP ;POWER POLE b EXISTING WELL, , ! im_� OVN,v POWER !r — dl aCYNE L do �, I, t+r— — — — up u - - OVHD r 4cP I — — up I � , ' � r SERVCE POLE I i , k �� +Y A ,_ _41 x 2N �\ 1.25 LBS. PRE LINEAR FOOT STEEL POSTS FILTER FABRIC - SILT FENCE - INSTALL IAW DETAIL A/C710. CONCRETE WASHOUT - INSTALL IAW SHEET C702 LIMITS OF CONSTRUCTION/DISTURBANCE 6' MgkIMUM Sp ACING BACKFILL TRENCH WITH - COMPACTED EARTH OFF HEAVY DUTY PLASTIC TIE FOR STEEL POSTS (RESTRICT TO TOP 8" OF FABRIC) 1. SEE SHEETS C701-C703 FOR ADDITIONAL CONTROL NOTES. 2. ALL CONTRACTORS/SUBCONTRACTORS/PERSON THAT WILL BE ENGAGED IN LAND DISTURBING ACTIVITIES SHALL COMPLY WITH ALL EROSION CONTROL AND STORMWATER POLLUTION PREVENTION REQUIREMENTS CONTAINED THROUGHOUT THE DRAWINGS, SPECIFICATIONS AND PERMITS. FILTER FABRIC COMPACTED EARTH RUNOFF a HEAVY DUTY PLASTIC TIES USE EITHER FLAT -BOTTOM _/ OR V-BOTTOM TRENCH BURY FABRIC SHOWN BELOW SILT FE CE INSTALLATION FLAT —BOTTOM TRENCH DETAIL GENERAL NOTES: FABRIC REQUIREMENTS: POST REQUIREMENTS: 1. DO NOT PLACE SILT FENCE ACROSS CHANNELS 1. SILT FENCE MUST BE COMPOSED OF 1. SILT FENCE POSTS MUST BE 48-INCH HER OR IN OTAREAS SUBJEC TO CONCENTRATED WOVEN GEOTEXTILE FILTER FABRIC THAT LONG STEEL POSTS THAT MEET, AT A FLOWS. SILT FENCE SHOULD NOT BE USED AS A CONSISTS OF THE FOLLOWING MINIMUM, THE FOLLOWING PHYSICAL VELOCITY CONTROL BMP. CONCENTRATED FLOWS REQUIREMENTS: CHARACTERISTICS. ARE ANY FLOWS GREATER THAN 0.5 CFS. - COMPOSED OF FIBERS CONSISTING OF - COMPOSED OF A HIGH STRENGTH STEEL 2. MAXIMUM SHEET OR OVERLAND FLOW PATH LONG CHAIN SYNTHETIC POLYMERS OF WITH A MINIMUM YIELD STRENGTH OF LENGTH TO THE SILT FENCE SI ALL BE 100-FEET. AT LEAST 85q BY WEIGHT OF 50 000 PSI. POLYOLEFINS, POLYESTERS, OR - INCLUDE A STANDARD "T" SECTION WITH 3. MAXIMUM SLOPE STEEPNESS (NORMAL POLYAMIDES THAT ARE FORMED INTO A A NOMINAL FACE WIDTH OF 1.38-INCHES (PERPENDICULAR] TO THE FENCE LINE) SHALL BE NETWORK SUCH THAT THE FILAMENTS AND A NOMINAL "T" LENGTH OF OR YARNS RETAIN DIMENSIONAL 1.48-INCHES. 2:1• STABILITY RELATIVE TO EACH OTHER; - WEIGH 1.25 POUNDS PER FOOT (f 8%) - FREE OF ANY TREATMENT OR COATING 4. SILT FENCE JOINTS, WHEN NE ESSARY, SHALL BE WHICH MIGHT ADVERSELY ALTER ITS 2. POSTS SHALL BE EQUIPPED WITH COMPLETED BY ONE OF THE FOLLOWING OPTIONS: PHYSICAL PROPERTIES AFTER PROJECTIONS TO AID IN FASTENING OF - WRAP EACH FABRIC TOGETHER AT A SUPPORT INSTALLATION; FILTER FABRIC. POST WITH BOTH ENDS FASTENED TO THE POST, - FREE OF ANY DEFECTS OR FLAWS THAT WITH A 1-FOOT MINIMUM OVERLAP; SIGNIFICANTLY AFFECT ITS PHYSICAL 3. STEEL POSTS MAY NEED TO HAVE A - OVERLAP SILT FENCE BY NSTALLING 3-FEET AND/OR FILTERING PROPERTIES; AND, METAL SOIL STABILIZATION PLATE WELDED PASSED THE SUPPORT POST TO WHICH THE NEW - HAVE A MINIMUM WIDTH OF 36-INCHES. NEAR THE BOTTOM WHEN INSTALLED SILT FENCE ROLL IS ATTACHED. ATTACH OLD ALONG STEEP SLOPES OR INSTALLED IN ROLL TO NEW ROLL WITH HEAVY-DUTY PLASTIC 2, 12-INCHES OF THE FABRIC SHOULD BE LOOSE SOILS. THE PLATE SHOULD HAVE TIES; OR, PLACED WITHIN EXCAVATED TRENCH AND A MINIMUM CROSS SECTION OF - OVERLAP ENTIRE WIDTH OF EACH SILT FENCE TOED IN WHEN THE TRENCH IS 17-SQUARE INCHES AND BE COMPOSED ROLL FROM ONE SUPPORT POST TO THE NEXT BACKFILLED. OF 15 GAUGE STEEL, AT A MINIMUM. THE SUPPORT POST. METAL SOIL STABILIZATION PLATE SHOULD 5. ATTACH FILTER FABRIC TO THE STEEL POSTS 3. FILTER FABRIC SHALL BE PURCHASED IN BE COMPLETELY BURIED. USING HEAVY-DUTY PLASTT LE TIES THAT ARE NGTOROLLS AND CUT TO THE EVENLY SPACED WITHIN THE TOP 8-INCHES OF LENGTHH OFF THE BARRIER TO AVOID 4. INSTALL POSTS A MINIMUM OF THE FABRIC. JOINTS. 24-INCHES. A MINIMUM HEIGHT OF 1- TO 2- INCHES ABOVE THE FABRIC SHALL BE 6. INSTALL THE SILT FENCE PER ENDICULAR TO THE 4. FILTER FABRIC SHALL BE INSTALLED AT MAINTAINED, AND A MAXIMUM HEIGHT OF DIRECTION OF THE STORMWA R FLOW AND PLACE A MINIMUM OF 24-INCHES ABOVE THE 3 FEET SHALL BE MAINTAINED ABOVE THE SILT FENCE THE PROP R DISTANCE FROM GROUND. THE GROUND. THE TOE OF STEEP SLOPES TO PROVIDE 5. POST SPACING SHALL BE AT A MAXIMUM SEDIMENT STORAGE AN ACCESS FOR OF 6-FEET ON CENTER. MAINTENANCE AND CLEANOUT. 7. INSTALL SILT FENCE CHECKS (TIE -BACKS) EVERY 50-100 FEET, DEPENDENT ON SLOPE, ALONG SILT FENCE THAT IS INSTALLED WITH SLOPE AND WHERE CONCENTRATED FLOWS ARE EXPECTED OR ARE DOCUMENTED ALONG THE PROPOSED/INSTALLED SILT FE CE. O SILT FENCE DETAIL NOT TO SCALE 40 HEAVY DUTY FILTER FABRIC PLASTIC TIES COMPACTED EARTH N RUNOF o a z - z N BURY FABRIC AT LEAST 12" V—SHAPED TRENCH DETAIL INSPECTION AND MAINTENANCE: THE KEY TO FUNCTIONAL SILT FENCE IS WEEKLY INSPECTIONS, ROUTINE MAINTENANCE, AND REGULAR SEDIMENT REMOVAL. REGULAR INSPECTIONS OF SILT FENCE SHALL BE CONDUCTED ONCE EVERY CALENDAR WEEK AND, AS RECOMMENDED, WITHIN 24-HOURS AFTER EACH RAINFALL EVEN THAT PRODUCES 1/2-INCH OR MORE OF PRECIPITATION. ATTENTION TO SEDIMENT ACCUMULATIONS ALONG THE SILT FENCE IS EXTREMELY IMPORTANT. ACCUMULATED SEDIMENT SHOULD BE CONTINUALLY MONITORED AND REMOVED WHEN NECESSARY. REMOVE ACCUMULATED SEDIMENT WHEN IT REACHES 1/3 THE HEIGHT OF THE SILT FENCE. REMOVED SEDIMENT SHALL BE PLACED IN STOCKPILE STORAGE AREAS OR SPREAD THINLY ACROSS DISTURBED AREA. STABILIZE THE REMOVED SEDIMENT AFTER IT IS RELOCATED. CHECK FOR AREAS WHERE STORMWATER RUNOFF HAS ERODED A CHANNEL BENEATH THE SILT FENCE, OR WHERE THE FENCE HAS SAGGED OR COLLAPSED DUE TO RUNOFF OVERTOPPING THE SILT FENCE, INSTALL CHECKS/TIE-BACKS AND/OR REINSTALL SILT FENCE, AS NECESSARY. CHECK FOR TEARS WITHIN THE SILT FENCE, AREAS WHERE SILT FENCE HAS BEGUN TO DECOMPCSE, AND FOR ANY OTHER CIRCUMS"ANCE THAT MAY RENDER THE SILT FENCE INEFFECTIVE. REMOVED DAMAGED SILT FENCE AND REINSTALL NEW SILT FENCE IMMEDIAT-LY. SILT FENCE SHOULD BE REMOVED WITHIN 30 DAYS AFTER FINAL STABILIZATION IS ACHIEVED AND ONCE IT IS REMOVED, THE RESULTING DISTURBED AREA SHALL BE PERMANENTLY STABILIZED. HORIZONTAL SCALE 0 20 40 80 160 ( IN FEET ) 1 inch = 40 ft. N _ Q U 0 Z WcV W ry u t!3 C)_� Qr-jz Q O w J � m �U� C U ENGINEER CHARLESTON\COLUMBIA\GREENI 25 WOODS LAKE ROAD, SUITE 210 GREEVILLE, SC 29607 ph: 864-751-9121 WWW.ADCENGINEERING.COM Know what's beloV Call before ya DATE: 7118/2022 ADC PROJECTM 22324 DESIGNED: CDG CHECKED: CDG DRAWN: CDG REVISION: EROSION CONTROL PLAN PERMIT DOCUMENTS