HomeMy WebLinkAboutNCG120087_2022 DMR_20220509NCDEQ Division of Energy, Mineral and Land Resources
Stormwater Discharge Monitoring Report (DMR) Form for NCG120000
Landfills
Click here for instructions
Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within
30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office.
Certificate of Coverage No. NCG12 0087
Facility Name: Johnston County Landfill
Facility County: Johnston
Discharge during this period: ❑Yes
Person Collecting Samples: Michael J. Liebl (S+G)
Laboratory Name: Pace Analytical
Laboratory Cert. No.: 37738
No (if no, skip to signature and date)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances?
If so, which Tier (I, II, or III)?
A copy.of this DMR has been uploaded electronically via httr3s://edocs.deg.nc.gov/Forms/SW-
Date Uploaded:
Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red)
Yes I✓I No
✓❑ Yes ❑ No
Parameter
Code
Parameter
Outfall SDO-A
Outfall soo-0A-5A Outfall SDO-13
Outfall
Outfall
N/A
Receiving Stream Class
No Discharge
No Discharge
No Discharge
N/A
Date Sample Collected MM/DD/YYYY
46529
24-Hour Rainfall in inches
C0530
TSS in mg/L (100 or 50*)
00400
pH in standard units (6.0-9.0)
00340
Chemical Oxygen Demand in mg/L
(120)
31616
Fecal Coliform in # per 100 ml (1000)
Additional parameters for outfalls in drainage areas that use >55 gallons per month of new hydraulic oil on average
00552
Non -Polar Oil & Grease in mg/L (15)
NCOIL
Estimated New Motor/Hydraulic Oil
Usage in gal/month
Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L
Notes (optional): Results for January 2022 monitoring period.
11
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information
submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting
false informatioU_La u�jng the possibility of fines and imprisonment for knowing violations."
Signature of Per ittee or Delegated Authorized Individual
Email Address rick.proctor@johnstonnc.com
Date
Phone Number