Loading...
HomeMy WebLinkAboutNCG240016_2022 DMR_20220505P.agURG eo U Z x RTy CAROv MECKLENBURG COUNTY Land Use & Environmental Services Agency Solid Waste May 5, 2022 DEQ Mooresville Regional Office Attn: DEMLR Stormwater Program 610 East Center Avenue Suite 301 Mooresville, NC 28115 Attention: DEMLR Stormwater Program Subject: Discharge Monitoring Report Mecklenburg County Compost Central — Certificate of Coverage No. NCG240016 Dear Central Files: Please find enclosed the Discharge Monitoring Report, April 2022, for Mecklenburg County Compost Central, a Type I facility located at 5631 West Blvd, North Carolina. If you have any questions, please contact me at 704- 634-7705 or by email at khaliem.adams(amecklenburgcoun . nc.gov. Sincerely, Khaliem Adams Solid Waste Environmental Specialist Enclosed: 2022 DMR PEOPLE • PRIDE PROGRESS • PARTNERSHIP 2145 Suttle Avenue Charlotte, North Carolina 28208 www.wipeoutwaste.com NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG240000 Compost Operations Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG24 0016 Person Collecting Samples: Khaliem Adams Facility Name: Mecklenburg County Compost Central Laboratory Name: Pace Analytical Facility County: Mecklenburg Laboratory Cert. No.: Discharge during this period: ✓❑ Yes ❑ No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? ❑✓ Yes ❑ No If so, which Tier (I, II, or III)? Tier 2 A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR ❑✓ Yes [-]No Date Uploaded: Analytical Monitoring Requirements for Outfalls with Industrial Activities - Benchmarks in (Red) Parameter Parameter Outfall2 Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class N/A Date Sample Collected MM/DD/YYYY 4/07/2022 46529 24-Hour Rainfall in inches 1.55 in C0530 TSS in mg/L (100) 8.3 00340 Chemical Oxygen Demand (120) 132 31615 Fecal Coliform in colonies per. 100 ml 6000 (1000) 600 Total Nitrogen in mg/L(30) 3.2 665 Total Phosphorus in mg/L (2) 0.85 400 pH in standard units (6.0-9.0) 8.46 Copper, total recoverable in mg/L 01119 (0.010) 0.0055 Lead, total recoverable in mg/ L 01051 (0.075) <0.050 Zinc, total recoverable in mg/ L 01094 (0.126) 0'010 Additional parameters for outfalls in drainage areas that use >55 gallons per month of new hydraulic oil on average 00552 Non -Polar Oil & Grease in mg/L (15) <4.9 Estimated New Motor/Hydraulic Oil NCOIL Usage in gal/month 75ga1/month Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." of Permittee or Delegated Authorized Individual r1f - /-ZZ- Date Email Address Phone Number Facility Name I Sample Location Sample Time pH Date Device Used to Sample Mecklenburg County Compost Central I Outfall 2 1230 8.46 4/7/2022 Horiba pH meter aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 April 13, 2022 Darren Steinhilber Mecklenburg County Solid Waste 2145 Suttle Ave Charlotte, NC 28208 RE: Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 Dear Darren Steinhilber: Enclosed are the analytical results for sample(s) received by the laboratory on April 07, 2022. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services -Asheville • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Matthew Brainard matthew.brainard@pacelabs.com (704)875-9092 Project Manager Enclosures cc: Khaliem Adams, Meclenburg County Solid Waste REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 Pace Analytical Services Charlotte South Carolina Laboratory ID: 99006 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Laboratory ID: 99006 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 North Carolina Drinking Water Certification #: 37712 North Carolina Wastewater Certification #: 40 CERTIFICATIONS South Carolina Certification #: 99006001 South Carolina Drinking Water Cert. #: 99006003 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Louisiana DoH Drinking Water#: LA029 Virginia/VELAP Certification #: 460221 South Carolina Laboratory ID: 99030 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 SAMPLE ANALYTE COUNT Project: Pace Project No.: COMPOST CENTRAL 1 92597815 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92597815001 OUTFALL 2 EPA 1664B ICO 1 PASI-C EPA 1664B ICO 1 PASI-C EPA 200.7 Rev 4.4 1994 CBV 3 PASI-A SM 9222D-2015 KDF 1 PASI-C SM 254OD-2015 MAB2 1 PASI-A TKN+NO3+NO2 Calculation KDF1 1 PASI-A EPA 351.2 Rev 2.0 1993 MFO 1 PASI-A EPA 353.2 Rev 2.0 1993 KDF1 1 PASI-A EPA 365.1 Rev 2.0 1993 KDF1 1 PASI-A SM 5220D-2011 MDW 1 PASI-A PASI-A = Pace Analytical Services - Asheville PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 Sample: OUTFALL 2 Lab ID: 92597815001 Collected: 04/07/22 12:46 Received: 04/07/22 13:14 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Oil and Grease ND mg/L 4.9 1 04/07/22 23:03 1664 SGT-HEM, TPH Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Total Petroleum Hydrocarbons ND mg/L 4.9 1 04/07/22 23:03 200.7 MET ICP Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Pace Analytical Services - Asheville Copper 0.0055 mg/L 0.0050 1 04/09/22 16:00 04/11/22 06:51 7440-50-8 Lead ND mg/L 0.0050 1 04/09/22 16:00 04/11/22 06:51 7439-92-1 BC Zinc ND mg/L 0.010 1 04/09/22 16:00 04/11/22 06:51 7440-66-6 BC MBIO 9222D Fecal Coliform CHT Analytical Method: SM 9222D-2015 Preparation Method: SM 9222D-2015 Pace Analytical Services - Charlotte Fecal Coliforms 6000 CFU/100 mL 1.0 1 04/07/22 18:02 04/08/22 16:06 u2 2540D Total Suspended Solids Analytical Method: SM 2540D-2015 Pace Analytical Services - Asheville Total Suspended Solids 8.3 mg/L 3.6 1 04/11/22 14:13 Total Nitrogen Calculation Analytical Method: TKN+NO3+NO2 Calculation Pace Analytical Services - Asheville Total Nitrogen 3.2 mg/L 0.040 1 04/13/22 16:04 351.2 Total Kjeldahl Nitrogen Analytical Method: EPA 351.2 Rev 2.0 1993 Preparation Method: EPA 351.2 Rev 2.0 1993 Pace Analytical Services - Asheville Nitrogen, Kjeldahl, Total 2.8 mg/L 0.50 1 04/12/22 06:30 04/13/22 03:07 7727-37-9 353.2 Nitrogen, NO2/NO3 pres. Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services - Asheville Nitrogen, NO2 plus NO3 0.45 mg/L 0.040 1 04/13/22 11:19 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services - Asheville Phosphorus 0.85 mg/L 0.050 1 04/12/2212:00 04/12/2215:00 7723-14-0 5220D COD Analytical Method: SM 5220D-2011 Preparation Method: SM 5220D-2011 Pace Analytical Services - Asheville Chemical Oxygen Demand 132 mg/L 25.0 1 04/12/22 20:20 04/12/22 22:57 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 04/13/2022 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 4 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 QC Batch: 690198 Analysis Method: EPA 1664B QC Batch Method: EPA 1664B Analysis Description: 1664 HEM, Oil and Grease Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92597815001 METHOD BLANK: 3606985 Associated Lab Samples: 92597815001 Parameter Units Oil and Grease mg/L LABORATORY CONTROL SAMPLE: 3606986 Parameter Units Oil and Grease mg/L MATRIX SPIKE SAMPLE: 3606987 Parameter Units Oil and Grease mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 04/07/22 23:03 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 40 35.1 88 78-114 92597783001 Spike MS MS % Rec Result Conc. Result % Rec Limits Qualifiers ND 38.5 33.4 85 78-114 SAMPLE DUPLICATE: 3606988 92597815001 Dup Parameter Units Result Result Oil and Grease mg/L ND ND RPD Qualifiers Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 04/13/2022 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 5 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 QC Batch: 690199 Analysis Method: EPA 1664B QC Batch Method: EPA 1664B Analysis Description: 1664 SGT-HEM, TPH Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92597815001 METHOD BLANK: 3607002 Associated Lab Samples: 92597815001 Parameter Units Total Petroleum Hydrocarbons mg/L LABORATORY CONTROL SAMPLE: 3607003 Parameter Units Total Petroleum Hydrocarbons mg/L MATRIX SPIKE SAMPLE: 3607004 Parameter Units Total Petroleum Hydrocarbons mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 04/07/22 23:03 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 20 14.3 72 64-132 92597783001 Spike MS MS % Rec Result Conc. Result % Rec Limits Qualifiers ND 19.2 14.2 70 64-132 SAMPLE DUPLICATE: 3607005 92597815001 Dup Parameter Units Result Result Total Petroleum Hydrocarbons mg/L ND ND RPD Qualifiers Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 04/13/2022 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 QC Batch: 690577 Analysis Method: EPA 200.7 Rev 4.4 1994 QC Batch Method: EPA 200.7 Rev 4.4 1994 Analysis Description: 200.7 MET Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92597815001 METHOD BLANK: 3608821 Matrix: Water Associated Lab Samples: 92597815001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Copper mg/L ND 0.0050 04/11/22 05:49 Lead mg/L ND 0.0050 04/11/22 05:49 Zinc mg/L ND 0.010 04/11/2218:10 LABORATORY CONTROL SAMPLE: 3608822 Spike LCS LCS % Rec Parameter Units Cone. Result % Rec Limits Qualifiers Copper mg/L 0.5 0.52 103 85-115 Lead mg/L 0.5 0.51 103 85-115 Zinc mg/L 0.5 0.51 103 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3608823 3608824 MS MSD 92597503001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Copper mg/L ND 0.5 0.5 0.54 0.54 107 107 70-130 0 Lead mg/L ND 0.5 0.5 0.51 0.50 101 100 70-130 0 Zinc mg/L ND 0.5 0.5 0.51 0.50 102 99 70-130 3 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3608825 3608826 MS MSD 92597501001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Copper mg/L ND 0.5 0.5 0.52 0.52 103 103 70-130 0 Lead mg/L ND 0.5 0.5 0.52 0.52 103 103 70-130 0 Zinc mg/L ND 0.5 0.5 0.53 0.53 105 105 70-130 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 04/13/2022 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 QC Batch: 690428 Analysis Method: SM 9222D-2015 QC Batch Method: SM 9222D-2015 Analysis Description: 9222D Fecal Coliform(MF) - CHT Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92597815001 METHOD BLANK: 3607974 Associated Lab Samples: 92597815001 Parameter Fecal Coliforms SAMPLE DUPLICATE: 3607975 Parameter Fecal Coliforms Matrix: Water Blank Reporting Units Result Limit Analyzed Qualifiers CFU/100 mL ND 1.0 04/08/22 16:06 92597783001 Dup Units Result Result RPD Qualifiers CFU/100 mL 6000 600 164 D6,u2 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 04/13/2022 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 QC Batch: 690631 Analysis Method: SM 2540D-2015 QC Batch Method: SM 254OD-2015 Analysis Description: 2540D Total Suspended Solids Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92597815001 METHOD BLANK: 3608988 Associated Lab Samples: 92597815001 Parameter Units Total Suspended Solids mg/L LABORATORY CONTROL SAMPLE: 3608989 Parameter Units Total Suspended Solids mg/L SAMPLE DUPLICATE: 3609537 Parameter Units Total Suspended Solids mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.5 04/11/2214:07 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 250 242 97 90-110 92597693002 Dup Result Result RPD Qualifiers 42.0 50.0 17 SAMPLE DUPLICATE: 3609538 92597937001 Dup Parameter Units Result Result Total Suspended Solids mg/L 850 690 RPD Qualifiers 21 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 04/13/2022 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 9 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 QC Batch: 690876 Analysis Method: EPA 351.2 Rev 2.0 1993 QC Batch Method: EPA 351.2 Rev 2.0 1993 Analysis Description: 351.2 TKN Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92597815001 METHOD BLANK: 3610180 Associated Lab Samples: 92597815001 Parameter Units Nitrogen, Kjeldahl, Total mg/L LABORATORY CONTROL SAMPLE: 3610181 Parameter Units Nitrogen, Kjeldahl, Total mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.50 04/13/22 02:58 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 10 9.9 99 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3610184 3610185 MS MSD 92597783001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Kjeldahl, Total mg/L 2.9 10 10 13.0 13.1 101 102 90-110 1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 04/13/2022 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 10 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 QC Batch: 691220 Analysis Method: EPA 353.2 Rev 2.0 1993 QC Batch Method: EPA 353.2 Rev 2.0 1993 Analysis Description: 353.2 Nitrate + Nitrite, preserved Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92597815001 METHOD BLANK: 3611818 Associated Lab Samples: 92597815001 Parameter Units Nitrogen, NO2 plus NO3 mg/L LABORATORY CONTROL SAMPLE: 3611819 Parameter Units Nitrogen, NO2 plus NO3 mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.040 04/13/2211:09 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 2.5 2.5 100 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3611820 3611821 MS MSD 92598037001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, NO2 plus NO3 mg/L 0.40 2.5 2.5 2.7 2.7 93 91 90-110 1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3611822 3611823 MS MSD 92598037002 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, NO2 plus NO3 mg/L 0.39 2.5 2.5 2.7 2.7 93 92 90-110 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 04/13/2022 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 11 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 QC Batch: 690905 Analysis Method: EPA 365.1 Rev 2.0 1993 QC Batch Method: EPA 365.1 Rev 2.0 1993 Analysis Description: 365.1 Phosphorus, Total Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92597815001 METHOD BLANK: 3610254 Associated Lab Samples: 92597815001 Parameter Units Phosphorus mg/L LABORATORY CONTROL SAMPLE: 3610255 Parameter Units Phosphorus mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.050 04/12/2214:53 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 2.5 2.6 103 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3610256 3610257 MS MSD 92597353001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Phosphorus mg/L 0.34 2.5 2.5 3.0 3.0 105 107 90-110 1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3610258 3610259 MS MSD 92597365001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Phosphorus mg/L 0.25 2.5 2.5 2.9 2.9 105 107 90-110 1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 04/13/2022 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 12 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 QC Batch: 691114 Analysis Method: SM 5220D-2011 QC Batch Method: SM 5220D-2011 Analysis Description: 5220D COD Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92597815001 METHOD BLANK: 3611438 Associated Lab Samples: 92597815001 Parameter Units Chemical Oxygen Demand mg/L LABORATORY CONTROL SAMPLE: 3611439 Parameter Units Chemical Oxygen Demand mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 25.0 04/12/22 22:51 Spike 1-CS LCS % Rec Cone. Result % Rec Limits Qualifiers 750 755 101 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3611440 3611441 MS MSD 92596618001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Chemical Oxygen Demand mg/L 51.3 100 100 153 151 102 100 90-110 2 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3611442 3611443 MS MSD 92597079001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Chemical Oxygen Demand mg/L 2020 100 100 2580 2620 563 598 90-110 1 M1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 04/13/2022 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 13 of 18 Pace Analytical Services, LLC aceArraiytical ® 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 www.paeelabs.enm (704)875-9092 QUALIFIERS Project: COMPOST CENTRAL 1 Pace Project No.: 92597815 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis ofAcrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS BC The same analyte was detected in an associated blank at a concentration above 1/2 the reporting limit but below the laboratory reporting limit. D6 The precision between the sample and sample duplicate exceeded laboratory control limits. M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. u2 Colonies are too numerous to count. Actual result may be greater than reported. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 04/13/2022 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 14 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Pace Project No.: COMPOST CENTRAL 1 92597815 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92597815001 OUTFALL 2 EPA 1664B 690198 92597815001 OUTFALL 2 EPA 1664B 690199 92597815001 OUTFALL 2 EPA 200.7 Rev 4.4 1994 690577 EPA 200.7 Rev 4.4 1994 690605 92597815001 OUTFALL 2 SM 9222D-2015 690428 SM 9222D-2015 690429 92597815001 OUTFALL 2 SM 254OD-2015 690631 92597815001 OUTFALL 2 TKN+NO3+NO2 691394 Calculation 92597815001 OUTFALL 2 EPA 351.2 Rev 2.0 1993 690876 EPA 351.2 Rev 2.0 1993 691192 92597815001 OUTFALL 2 EPA 353.2 Rev 2.0 1993 691220 92597815001 OUTFALL 2 EPA 365.1 Rev 2.0 1993 690905 EPA 365.1 Rev 2.0 1993 691000 92597815001 OUTFALL 2 SM 5220D-2011 691114 SM 5220D-2011 691172 Date: 04/13/2022 04:06 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 15 of 18 Document Name: Document Revised: November 15, 2021 h aCEAnalytical Sample Condition Upon Receipt (SCUR) Page 1 of 2 Document No.: Issuing Authority: F-CAR-CS-033-Rev.08 Pace Carolinas Quality Office Laboratory receiving samples: Asheville ❑ Eden❑ Greenwood ❑ Huntersville [� Sample Condition Client Name: Upon Receipt Courier: LJFed Ex ❑UPSJ CUSPS ❑ Commercial ❑Pace []Other: Custody Seal Present? ❑Yes [DNo Seals Intact? ❑Yes Raleigh❑ Mechanicsville❑ Atlanta❑ Kernersvillel l rai . WD#�9�597815 Client 92597515 I No Date/Initials Person Examining Contents; QL�,t•— Packing Material.• ❑Bubble Wrap ❑Bubble Hags None ❑ Other Biological Tissue rozen? I l L Thermomet , !-f� ,-,(/, []Yes❑Na [IN/A V I Gun ID: '2 C P'i Type of Ice: L'9wet []Blue❑None Correction Factor; Cooler Temp: Add/Subtract (°C) C1 Temp should be above freezing to VC []Samples out of temp criteria. Samples an ice, tooling process —Coal erTemp Corrected j: n u USDA Regulated Soli (Z] N/A, water samptel Did samples originate in a quarantine zone within the United States: CA, NY, or SC (check mapsi? Did samples originate from a foreign source (internationaiiy, nypt FINn inrludinp Hawali and Pimrtn Rieni? —iYac F1Nn Comments/Discrepancy: Chain of Custody Present? �/ E es ❑No ❑N/A 1. 5amples Arrived within Hold Time? dies [:]No ❑N/A 2. Short Hold Time Analysts (c72 hr.)? es [-)No r1f41A 3. Rush Turn Around Time Requested? []Yes QG ❑N/A a, Sufficient Volume? EfYes No ❑N/A 5. Correct Containers Used? es ❑No ❑N/A 6. -Pace Containers Used? ❑No ❑N/A Containers Intact? ,�Y%es f]iY es []Na /A 7. Dissolved analysis: Samples Field Filtered? ❑ es ❑No N/A B. Sample Labels Match COC? Yes ❑No ❑N/A 9. i� -Includes Date/Time/ID/Analysis Matrix: Headspace in VOA Vials (>5.6mm)? I-] Yes ❑No /A 10, Trip Blank Present? ❑Yes ❑Na N/A 11. Trip Blank Custody Seals Present? ❑Yes []No (�/A COMMENTS/SAMPLE DISCREPANCY Lot ID of split containers: CLIENT NOTIFICATION/RESOLUTION Person contacted: Date/Time: Project Manager SCURF Review: Date: Project Manager SRF Review: Date, Field Data Required? ❑Yes ❑No Page 16 of 18 Document Name: Document Revised: November 15, 2021 n Sample Condition Upon Receipt (SCt1R) Page 2 of 2 . 3CeAf13�j�IC�?� . Document No.: Issuing Authority: F-CAR-CS-033-Rev.08 Pace Carolinas Quality Office *Check mark top half of box If pH and/or dechlorination is verified and within the acceptance range for preservation samples. Exceptions: VOA, Coliform, TOC, Oil and Grease, DRO/9015 (water) DOC, LLHg **Bottom half of box Is to list number of bottles Project # 'WO# PM: MWB CLI EN'r : :92597815 Due Dale: 04/14/22 92—MECK CO 4E a w T 0 V \ Q Z = z I Z Z z Z �. ,Z ry a Z d a) a a v y o5 M o v vdi a ? z y I w z -0 n Z $ = Y Z Z N v a O m u x ro d n a V C O a = y� L ? m = u .M N � m n a a u a a O a c O ^ E z 0 v ° m z e g c 7 S x N z y 7 = _ _ = Q N .L y a a ? U N U U w M 4 U V U to U e+ N d b E U Z M Z fn i �-' .fr �+ Y GI GI 9 N A 7 c 4 E E a a 0 a > a O a O ;, N v m E Q c J E J E J £ rL y E d E J E J E E 0 a v a `5 J E Q E J E M m E E E E N > A E E J E N a E} 14 N IAA ri ry N .N N 7 r1 r-I N ri N It Y Y " rmr N N (pE7 O Q 1 Y - - a Y r- - E a� v a m a N a a a IL m iL v rL a C7 3 r+ ISL9 •� G �+, tv ,� m l7 U ai 0 0 0 m s7 m 0 O „r % N m ¢ > a m do m m in m m a a a a a a a a a o 9 a AA t � � I Z 2 3 4 5 6 . 7 B 9 10 tz N 11 .==-LLN I J I N�-i I I pH Adjustment Log for Preserved Samples Sample ID Type of Preservative pH upon receipt Date preservation adjusted Time preservation adjusted Amount of Preservative added Lot k Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina DEHNR Certification Office (Le. Out of hold, incorrect preservative, out of temp, incorrect containers, Page 17 of 18 m m n a 0 :0 m m H N r p eG W is [n A W N )TAM #m m -3 g o ro m a F a a Q P n v n a N W N w N 0 m nv V yVy�/ W 3 a N (A E. 61 CP ` ° . 7�' Y N N: m CFi ro c n fl �O ITi m m Q 0 ._. o m b x 0 " a rn z 1 � m =1 cU 1 10 N N p1 °O o m 3 v �J < ni < t to /'1 O➢� O� 9 Fe QD � a=g 3x n ZY m R u m z c o m; m r' O C rn �bv Order �m _ .- N •3 O Cl °m z m o o a 'm a .. y n m m ° 1< 1 :E MATRIX CODE (see valid codes to lefty 5AMPLE TYPE {G=GRAB C=COMP) m �"J a 3 0 n c < m @ m F D' 0 rn mj n D rn -0 � O IIG•J` m ra n-Z+ 70 z n f0 t m z o IT m o m 3 A m m m a m z m p SL -I n LA �r y� m v v r m v 3 r z m SAMPLE TEMP AT COLLECTION C O # OF CONTAINERS ami m m a p n m rho 3 3 o m i•c Unpreserved a m fl y v o' m.0 y m m CD_3 - .- H2SO4 m o�° ° HNO3 m m d �i ID N O N HCI m o ,4 NaOH w Na2S203 (D 0 a 1 m N Methanol f 3 m y ti m � Other m o c T Analyses Test YIN v v x X COD/Total Phosphorus a o D x x TSS m m _ a x x Fecal Cali m o p 5 n ym m n X X Total Nitrogen (TKN+n.lrate • c � x x 200.7ICP Metals 3 0 x x 11664 N o ^ti 3 x x TPH SGT-HEM 1664 y m T n c Cr m U rn a m m o. N a z I9 C31 TEMP in C Residual Chlorine {Y!N) ;z ° m a E `^ y a o Received on - o jc Ice v a {YIN) m 9 6 m o us o y o Ceooeer �r A i 0 (YIN)? m u Samples ntact I(YIN) CP = 0 m = n m Z 0 0 C n N � O n C m v D r o 0 0 m D = d ro � (p �m N N lift �a c m 0 n N �r0 a n n c N N 'C Page 18 of 18 Kir-110 rnvironmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit httsn //deg.nc.aov/about/divisions/energy-mineral-land- resources/energy-mineral-land-permits/stormwater-pennits/np des-industrial-sw#tab-4 Permit No.: N/C/ /1/ / / / /�/ or Ce 'ficate of Cover e No.: N/C/GIgill U/� Facility Name: P L - , �U.f`� nn % � �7 S1 I 'diet 1 County: e C '!� / Inspector: a I I r Date of Inspection: y / Time of Inspection: Total Event Precipitation (inches): ❑/ S Phone No. C-70 q ) I '� 2; -- All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: of Permittee or Designee) 1. Outfall Description: Pl Outfall No. A Structure (pipe, ditch, etc.): Receiving Stream: Describe the industrial -activities that occur within the outfall drainage area: Va f G 49 M a,4 iq, e", �ar.GQi d- C•tf 2!` f 'D —9/rn Page 1 of 2 SWU-242, Last modified 07/28/2017 2. Color: Describe the color of (light, medium, dark) as descriptors: _ 3. Odor: Describe any chlorine odor, etc.): using basic colors (red, brown, blue, etc.) and tint n, —. h r- A "i r1 odors that the discharge may have (i.e., smells strongly of oil, weak 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 2 3 4 5 7. Is there any foam in the stormwater discharge? O Yes /No. D 8. Is there an oil sheen in the stormwater discharge? oYes - No. N V 9. Is there evidence of erosion or deposition at the outfall? O Yes 9"N/o. N D 10. Other Obviou Indicators of Stormwater Pollution: List and describe i 0 0� Cf 10 (t ( c 4 o r .S Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 07/28/2017